Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Demonstration thermography report comparison between 320 x 240 versus 160 x 120 pixel configuration
1. Demonstration Thermography report
Company Testo Ltd Tester:
Newman Lane A McGrath - Testo
Alton, Hampshire, GU34 2QJ Phone: 01420 544433
E-Mail: info @testo.co.uk
Device Testo 881-3 & Testo 882 Serial No.: 01799300 / 01906938
Lens: 32 degree Wide Angle Lens
Customer Testo Ltd Measuring Site:
Newman Lane Demonstration Report
Alton Comparison of Quality of Images
320 x 240 pixels v 160 x120 pixels
Measuring Date: 15th November 2010
Task Demonstration Thermography Report to highlight the Differences in
Resolution between 320 x 240 pixels Testo 882 & 160 x 120 pixels Testo
881.
Page 1/10
2. Demonstration Thermography report
File: Date: Measuring Time:
IV_00040.BMT 20/10/2010 07:48:15
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 882 Thermal Imaging camera a 320 x 240 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 160 x 120 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 2/10
3. Demonstration Thermography report
File: Date: Measuring Time:
IV_01185.BMT 15/11/2010 07:15:27
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 881 Thermal Imaging camera a 160 x 120 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 320 x 240 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 3/10
4. Demonstration Thermography report
File: Date: Measuring Time:
IV_00089.BMT 21/10/2010 07:24:20
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 882 Thermal Imaging camera a 320 x 240 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 160 x 120 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 4/10
5. Demonstration Thermography report
File: Date: Measuring Time:
IV_01190.BMT 15/11/2010 07:16:42
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 881 Thermal Imaging camera a 160 x 120 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 320 x 240 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 5/10
6. Demonstration Thermography report
File: Date: Measuring Time:
IV_00091.BMT 21/10/2010 07:25:08
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 882 Thermal Imaging camera a 320 x 240 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 160 x 120 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 6/10
7. Demonstration Thermography report
File: Date: Measuring Time:
IV_01184.BMT 15/11/2010 07:14:57
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 881 Thermal Imaging camera a 160 x 120 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 320 x 240 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 7/10
8. Demonstration Thermography report
File: Date: Measuring Time:
IV_00092.BMT 21/10/2010 07:25:48
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 882 Thermal Imaging camera a 320 x 240 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 160 x 120 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Page 8/10
9. Demonstration Thermography report
File: Date: Measuring Time:
IV_01188.BMT 15/11/2010 07:16:05
Picture parameters:
Emissivity: 0.95
Refl. temp. [°C]: 20.0
Remarks:
Thermal and Digital images taken with a Testo 881 Thermal Imaging camera a 160 x 120 pixel configuration
Thermal Imaging Camera.
The image was taken for comparison purposes, to compare with a 320 x 240 pixel configuration Thermal
Imager, to highlight difference in image Quality / Resolution.
Image displayed in " Iron " Palette.
Review:
Demonstration Thermography Report to highlight the differences in the Thermal Image Quality and Resolution.
This is an example report for Demonstration purposes only. The format is produced in the "Standard" report
template from the selection of Report Templates available in the software.
This report is compiled to indicate the differences in the Quality and Resolution of the Thermal image when
comparing images taken with a Testo 882 Thermal Imaging camera, 320 x 240 pixels, 60mK Thermal
Sensitivity and a Testo 881-3 160 x 120 pixels, 80mK Thermal Sensitivity.
As can be seen and as expected, the image quality of the Testo 882 is superior.
The objective of the Report was to be able to provide a comparison in the quality of the Thermal Image
between the two pixel configurations.
The images are automatically Time and Date Stamped to verify the time and date when the images were
taken.
The report also details the Emissivity value relating to the image taken.
Page 9/10