2. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
Warning
Do not remove or insert any plugs whilst Spooky Central is
powered on. Turn off at the mains switch at the rear of Spooky
Central. The switch light should be off and there should be no
fan noise.
3. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
1. Connect your XM generator to Spooky Central.
OUT1 goes to INPUT. OUT2 goes to MODULATION.
2. Plug your ultrasonic speaker into the ULTRASONIC
output.
3. Plug the contact mode adapter cable into the CONTACT
output.
4. Plug the coil (if supplied) into COIL output.
4. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
5. Plug your plasma tube into the rear high voltage
sockets.
6. Plug in the mains cable.
7. Turn Spooky Central on at the rear switch.
5. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
8. Start the Spooky software.
9. Select the JW - Spooky Central preset.
10. Enter the frequencies you wish to run.
11. Run the program.
6. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
Important Notes
● We recommend our special USB filter cable for all
generators connected to the same computer as Spooky
Central. These are inexpensive and can be purchased from
spooky2-mall.com.
● All 4 subsystems (plasma, coil, ultrasonic and contact)
can be used together or individually if desired. Best results
will be achieved if they are run in combination.
● Spooky Central only accepts a 5v / 100% offset square
wave input.
●A spectrum sweep can be used, but it must use a square
wave and be 5v with 100% offset.
●INPUT must be 50% duty cycle. MODULATION can be
any duty cycle.
●Plasma modulation percentage = 100 – INPUT modulation.
7. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
● MODULATION input assists ionization (lighting) of the
plasma tube. The JW - Spooky Central preset provides a
slow beat frequency that greatly improves the effectiveness
of Spooky Central.
● Plasma tubes require a "burn in" period to reach optimum
performance. During this period impurities within the tube
are automatically removed.
● If the tube has difficulty lighting, please arrange the white
high voltage wires to be further apart.
Spooky Central has 2 inputs; an Input, and Modulation.
These 2 inputs control the plasma tube. The inputs should
be set as below, with critical settings highlighted.
8. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
9. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
Operational truth table of Spooky Central
0 – Off.
1 – On.
10. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
Specifications
Mains voltage : 230 or 110v (region specific)
Mains power (max) :< 150W
INPUT (INPUT & MODULATION) voltage: 5VDC
INPUT frequency range: 100 kHz – 3.5 MHz
MODULATION (optional input signal) voltage: 5VDC
MODULATION frequency range: 100 kHz – 3.5 MHz
High voltage output (RMS) : 543v
High voltage (peak): 9315v
Plasma tube power (max) : 40W
Frequency range: 100 kHz – 3.5 MHz*
*Minimum specification. Dependent on cable length, layout
and tube type.
11. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
Ultrasonic output: 29VAC
Ultrasonic power (max) : 2W
Ultrasonic optimum frequency range: 0 Hz – 1 MHz
Contact output: 320VDC / 0.5uS
Contact power (mean) : 150mW
Contact power (instantaneous, 1K load) : 102 Watts
Contact frequency: 100 Hz
Coil output: 29VDC / 69uS
Coil power (mean) :200mW
Coil power (instantaneous) :134 Watts
Coil frequency: 100 Hz
Coil field strength: 200 gauss
12. Official Support Website: www.spooky2.com
Official Purchasing Website: www.spooky2-mall.com
Email:echolee@cleanenergy-npt.com
or service@spooky2.com
Thank you!