WLL stainless steel wireless telemetry load link Datasheet (English). For use in lifting applications for high accuracy weighing and for load testing lifting equipment.
The portable VLF Test System 20 kV of Seba KMT can be used to test the cables in conjunction with the according local regulations for operating voltage levels up to 11 kV for new cables and 16 kV for aged cables at 3 μF cable capacity.
By using the patented Seba KMT 0.1 Hz Cosine Square Wave Voltage, weak and for further operation critical spots in PE, XLPE but also in paper cables are brought to a controlled breakdown very fast without causing additional damage or ageing to the cable insulation.
The SEBA KMT VLF Test System consists of a DC source, which charges the test object up to the required test voltage level and the commutator unit, which performs the regular 5 second interval polarity change.
Blind Spots of Low Voltage Testing Webinar Presented by Megger BakerTranscat
Find faults where they begin, not where they end.
When the highest reliability is demanded of your motors, high voltage testing is not just an option - it's a necessity. This webinar will focus on the theory and application of electric motor insulation testing techniques.
The portable VLF Test System 20 kV of Seba KMT can be used to test the cables in conjunction with the according local regulations for operating voltage levels up to 11 kV for new cables and 16 kV for aged cables at 3 μF cable capacity.
By using the patented Seba KMT 0.1 Hz Cosine Square Wave Voltage, weak and for further operation critical spots in PE, XLPE but also in paper cables are brought to a controlled breakdown very fast without causing additional damage or ageing to the cable insulation.
The SEBA KMT VLF Test System consists of a DC source, which charges the test object up to the required test voltage level and the commutator unit, which performs the regular 5 second interval polarity change.
Blind Spots of Low Voltage Testing Webinar Presented by Megger BakerTranscat
Find faults where they begin, not where they end.
When the highest reliability is demanded of your motors, high voltage testing is not just an option - it's a necessity. This webinar will focus on the theory and application of electric motor insulation testing techniques.
KEMET's line of off-the-shelf and custom filters cover a wide variety of applications. We combine our popular EMI Capacitors with our expertise in EMC testing, for a total solution.
Application areas include Motor Drives, Power Electronics, Electric Vehicle Chargers, PV Systems, Wind Turbines, Medical Equipment, 3D Printers, Laser Cutters, and Welding Machines.
For more information, visit www.kemet.com/emi-filter-guide
Experiences with MnO2 tantalum capacitors in the past may have caused some engineers to look at alternatives. However, a decade of a new Polymer tantalum solve many of the previous challenges, especially in Automotive applications.
KEMET's T598 Polymer Electrolytic Capacitor is an AEC-Q200 qualified solution for automotive.
Presented by Jayson Young at the 2016 AEC Reliability Workshop
The CliQ M series has the highest power density among the CliQ family and also the first series in the CliQ family to feature Advanced Power Boost (APB).
Catalog thiết bị đóng cắt Fuji Electric - Air Circuit Breakers DW Series
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
KEMET's line of off-the-shelf and custom filters cover a wide variety of applications. We combine our popular EMI Capacitors with our expertise in EMC testing, for a total solution.
Application areas include Motor Drives, Power Electronics, Electric Vehicle Chargers, PV Systems, Wind Turbines, Medical Equipment, 3D Printers, Laser Cutters, and Welding Machines.
For more information, visit www.kemet.com/emi-filter-guide
Experiences with MnO2 tantalum capacitors in the past may have caused some engineers to look at alternatives. However, a decade of a new Polymer tantalum solve many of the previous challenges, especially in Automotive applications.
KEMET's T598 Polymer Electrolytic Capacitor is an AEC-Q200 qualified solution for automotive.
Presented by Jayson Young at the 2016 AEC Reliability Workshop
The CliQ M series has the highest power density among the CliQ family and also the first series in the CliQ family to feature Advanced Power Boost (APB).
Catalog thiết bị đóng cắt Fuji Electric - Air Circuit Breakers DW Series
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog ACB dòng DW đến từ thương hiệu Fuji Electric.
Sản phẩm dễ dàng lắp đặt, đi kèm với thiết kế thân thiện với người dùng và môi trường.
The 5130 protects connected equipment from five of the most common power anomalies: failures, surges, sags, under-voltage and overvoltage @ www.ecopowersupplies.com
𝙎𝙪𝙣𝙬𝙤𝙙𝙖 𝙀𝙣𝙚𝙧𝙜𝙮 𝙂𝙧𝙤𝙪𝙥, listed in China & Swiss stock markets, Code [300207], with great bankability & business track records.
🏳️🌈 Asia battery Giant, Global Top 6 lithium-ion battery Suppliers
🏳️🌈 Offer wide range of solutions from Battery cells, Portable, Residential, C&I, and Utility battery storage systems in turnkey.
🏳️🌈 Establish in 1997, 26+ years focus on the energy market
🏳️🌈 50,000+ global staff, 12 production bases with 300GWh yearly production capacity
🏳️🌈 Solid Partnership with main energy players
🏳️🌈 Ranked 32 in Global renewable energy enterprises, 2022
🏳️🌈 OEM/ODM support with in-house RD team
#𝙒𝙝𝙖𝙩 𝙬𝙚 𝙨𝙪𝙥𝙥𝙡𝙮: Battery cells, Pack, Portable, Residential, C&I , Utility energy storage products & solutions.
# 𝘼𝙥𝙥𝙡𝙞𝙘𝙖𝙩𝙞𝙤𝙣 𝙎𝙘𝙚𝙣𝙖𝙧𝙞𝙤𝙨: Suits for Generation, Distribution, Behind meter 20+ applications
# 𝘽𝙪𝙨𝙞𝙣𝙚𝙨𝙨 𝙘𝙤𝙣𝙩𝙖𝙘𝙩 & 𝙁𝙧𝙚𝙚 𝙞𝙣𝙦𝙪𝙞𝙧𝙚𝙨: jenniferzhong@sunwoda.com
Fuji thiet bi dien-elcbfuji-160413044256Thuan Kieu
Fuji thiet bi dien-elcbfuji-160413044256
Catalog Fuji,
Catalog Thiết Bị Điện Fuji,
Catalog Điện Công Nghiệp Fuji,
http://dienhathe.com,
Xem thêm các sản phẩm khác của Fuji tại https://dienhathe.com
Để nhận báo giá sản phẩm Fuji vui lòng gọi: 0907.764.966
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
Similar to WLL stainless steel telemetry load link (English) (20)
LCM Systems are a designer and manufacturer of standard and custom design load cells, load pins and instrumentation systems. These are used in a variety of applications, including Marine, Offshore, Oil & Gas, Heavy Lift and crane safety. We also offer an extensive range of ATEX and IECx hazardous area certified products.
We were contacted by a leading Canadian aquaculture company who were looking for a monitoring system that could log the tension in mooring lines that anchored tanks used for the farming of salmon to the sea bed. They had seen the SHK-B load
shackle range on our website, but as it would be located at a depth of around 4.5 metres, needed a special subsea version. An initial system was required for testing purposes (carried out in a tow tank), but if successful multiple systems would be fitted to the fish tanks out in the field. The requirement was to monitor the loads on the mooring
engineers designed an IP68 enclosure for housing the data logging electronics, which was simple to open to facilitate easy access to the SD card and to replace the batteries. Lithium batteries were chosen to provide maximum battery life (around 90 days) and the data logger chosen featured low noise, high resolution and low power consumption, with the provision for 2 readings per minute. Data output was in Excel format for straight forward importation to a PC for analysis.
The enclosure was connected to the load shackle via a 1 metre cable and housed within a float to keep it away from the mooring lines, to avoid any possibility of it becoming entangled during stormy seas.
lines to check that they did not exceed safe operational limits, particularly during severe weather conditions. A data logger was required to record measurement readings from the load shackle, which as well as being suitable for long term submersion underwater, also needed to be able to operate unattended for long periods between retrieval of the monitoring system for data download. LCM System engineers designed an IP68 enclosure for housing the data logging electronics, which was simple to open to facilitate easy access to the SD card and to replace the batteries. Lithium batteries were chosen to provide maximum battery life (around 90 days) and the data logger chosen featured low noise, high resolution and low power consumption, with the provision for 2 readings per minute. Data output was in Excel format for straight forward importation to a PC for analysis.
The enclosure was connected to the load shackle via a 1 metre cable and housed within a float to keep it away from the mooring lines, to avoid any possibility of it becoming entangled during stormy seas.
Larsen & Toubro, a leading Indian engineering and construction contractor, were commissioned to build a nuclear containment building at Kakrapar Atomic Power Plant. As part of the project they needed to lift and position a 47 metre
diameter and 8.25 metre high inner containment dome liner, which had been built as a single unit. Because of the unique geometry of the dome and its 365 tonne weight, a balanced lift with equally distributed loads was vital to ensure a safe and successful lift. Eighteen lifting lugs were integrated into the dome liner, which were each fitted with
loaded throughout the lift. With only 200mm clearance to work with, the Larsen & Toubro team lifted and placed the dome into position on top of the inner containment wall in just two hours, with alignment and anchoring taking a further three hours, after which the crane was released.
Larsen & Toubro commented “During test runs the turnbuckles where rotated according to the load displayed on all 18 load shackles to distribute the loads equally. This test was demonstrated to our client and the regulatory board, who were then happy to give their permission to lift the dome on the very next day.”
a 55te wireless load shackle. At the customers request, a Crosby G2130 was used, rather than the smaller standard TELSHACK-B 55te, as it afforded a better fit within the lifting lugs.
LCM Systems also supplied a telemetry base station that detected the telemetry signals from the load shackles and transmitted them to a laptop, where engineers were able to view the loads on each lifting lug to ensure they remained uniformly loaded throughout the lift. With only 200mm clearance to work with, the Larsen & Toubro team lifted and placed the dome into position on top of the inner containment wall in just two hours, with alignment and anchoring taking a further three hours, after which the crane was released.
Larsen & Toubro commented “During test runs the turnbuckles where rotated according to the load displayed on all 18 load shackles to distribute the loads equally. This test was demonstrated to our client and the regulatory board, who were then happy to give their permission to lift the dome on the very next day.”
We were contacted by a longstanding
customer about the feasibility of supplying them with a SOLAS compliant container weighing system. We had been supplying this specialist straddle carrier and forklift manufacturer with container weighing
systems for around five years, which they offered as an option on their straddle carrier range. With the introduction of updates to the SOLAS regulations, which stipulates that all containers must have a verified weight prior to shipping, they wanted a bespoke system to meet the standard that could be fitted to their equipment.
To meet the new legislative requirements, LCM Systems had to redesign the electronics of their existing system, and also introduce a new tablet display that showed the load on each individual pin and the total weight. Two existing load bearing pins were replaced with custom designed 25 tonne load measuring pins, which connect to an interface module where the mV/V output signal is converted to RS485 and the data then sent to the in-cab tablet display.
The new system was designed with pre-wired cable assemblies for connection to the interface module to allow installation to be carried out by untrained personnel, and also to facilitate fast and easy replacement of cables in the event of any becoming damaged. The tablet display, in addition to showing weight information, also has an in-built function that only allows the weight to be recorded once stable to ensure accuracy. It also includes a tare function and the facility to enter container numbers and generate reports.
For this project, we were contacted by a manufacturer of diving equipment, who were interested in having custom design load pins manufactured that were suitable for use in a marine/offshore environment. Because they would be used in a lifting
application that involved personnel, the traceability requirements were high, with 3.1 material certificates and charpy testing required. These load pins were required to measure the loads applied to the handling systems of the diving bells. The diving bells
are lifted ready for deployment through a dedicated opening in the centre of the vessel called a moon pool, and are also recovered using the same lifting system. Next to the moon pool there are a series of vertical sheaves, which connect to the diving bell. The plan was to have load pins installed in these sheaves to determine the weight of the diving bell. This would ensure that there were no overload situations, which could potentially endanger the personnel inside.
Four load pins are installed per moon pool lifting system, each rated to 1000kN. Manufactured from stainless steel and with
environmental sealing to IP67 for suitability in a marine environment, the load pins feature an internal amplifier to provide 4-20mA output. This allows the load measurement data to be exported direct to the vessels PLC system, where the results can be displayed and monitored for safety purposes.
The load pins were designed, manufactured and delivered within the required time frame, and the customer was very happy with their performance. They have since gone on to place orders for several more systems.
This requirement was for an international offshore drilling contractor that provides oilfield services for offshore oil & gas production, specialising in the ultra-deepwater sector. They needed ATEX Zone 2 rated load shackles with displays
and alarms for one of their deep water drillships that was being deployed off the Angola coast on the ultra-deepwater Kaombo project. Due to their clients stringent rules regarding hazardous areas, they needed certified products in order to comply. LCM Systems designed a system to meet their requirements that comprised of 3 x 12 tonne
environment, all cable supplied was RFOU (I) 250V armoured mud resistant power/instrumentation cable, specifically designed for safety critical systems in both EX and safe areas.
The load shackles were required to monitor the loads on umbilical roller sheaves as they payed out the hose to ensure that it did not become sagged and to check that the hydraulic hose reels were operating correctly. Each load shackle had its own display to show the individual loads, and all three were set to trigger an audio and visual alarm in the event of a pre-set limit being reached. A second display and alarm system was incorporated into the drilling cabin for remote system monitoring.
We subsequently received an identical order for the same system for another deep water drillship operator working on the same project.
load shackles and an ATEX junction box to be situated at the top of an A-Frame, which was wired to another ATEX junction box at its base and connected to 3 channel ATEX display and alarm system (see photo below). Also connected to this junction box was an additional display and alarm system located below deck in the driller cabin, which, because it was located in the Safe Area, was not required to be ATEX certified. Due to the harsh operating environment, all cable supplied was RFOU (I) 250V armoured mud resistant power/instrumentation cable, specifically designed for safety critical systems in both EX and safe areas.
The load shackles were required to monitor the loads on umbilical roller sheaves as they payed out the hose to ensure that it did not become sagged and to check that the hydraulic hose reels were operating correctly. Each load shackle had its own display to show the individual loads, and all three were set to trigger an audio and visual alarm in the event of a pre-set limit being reached. A second display and alarm system was incorporated into the drilling cabin for remote system monitoring.
We subsequently received an identical order for the same system for another deep water drillship operator working on the same project.
WLL Inel de sarcină WLL fără cablu, din otel inoxidabil (Romanian). Pentru utilizarea la ridicarea aplicațiilor pentru cântărirea cu precizie ridicată și pentru echipamentele de ridicare de încercare a sarcinii.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
1. WLL Stainless Steel Wireless
Load Link
TYPE: WLL
Features
Ranges: 5 to 100 tonne
Stainless steel construction (17-4PH
H900)
Environmentally sealed to IP67
Simple installation and operation
Special sizes and ranges available
Higher range versions available
Machinery Directive 2006/42/EC
compliant
Typical Applications
Cable tension monitoring
Under-hook hoist and crane
weighing
Towing/mooring tension
Crane safe load monitoring
Water bag weighing
Lifting gear testing
The WLL series of wireless load monitoring links have been designed for lifting and
weighing in rugged or harsh environments, being manufactured from stainless steel for
corrosion resistance. It also comes supplied complete with a 3.1b material certificate as
standard, complies with the European Machinery Directive 2006/42/EC and is supplied in a
robust storage case.
The WLL wireless series are simple to install and are matched to standard shackle sizes. The
unique wireless housing is manufactured from semi-aromatic polyamide plastic making the
load link far more compact and reducing the overall product weight. Located in the
housing are two AAA alkaline batteries which can be easily accessed by removing the
telemetry housing cover, while the internal electronics underneath remain completely
sealed. The antenna is also internally mounted, protecting it from accidental damage
during use and handling. The batteries are standard AAA alkaline batteries, which are
readily available and low cost.
The wireless WLL is also supplied as standard with a handheld battery powered display
(T24-HS-LS) , or alternatively, for multi-linkwhich can display in both tonnes or lbs
applications, a single display (T24-HA) can address up to 12 links for individual monitoring,
or for summation/balancing applications. The built in wireless electronics operates on the
2.4GHz license free frequency, with a robust proprietary protocol, providing interference
free communications.
For more complex systems, including datalogging or monitoring/reporting requirements,
we are able to offer a robust tablet PC with installed software for use with single or multiple
load cell installations.
The WLL wireless series can be supplied as shown in this data sheet, or can be modified to
meet a particular application requirement. We are always pleased to discuss any special
requirements that can be accommodated.
Specification
Description
Rated load (tonne)
Proof load
Ultimate breaking load
Accuracy
Non-repeatability
Transmission distance
Battery life
Battery
Operating temperature range
Compensated temperature range
Zero temperature coefficient
Span temperature coefficient
Environmental protection level
Approvals
5, 12, 25, 35, 50, 100
200% of rated load
>500 % of rated load
<±0.15% of rated load
<±0.1% of rated load
Up to 600 metres (clear line of sight)
>300 hours (continuous use, with 1.2Ah batteries)
AAA Alkaline x 2 (supplied with 1.2Ah batteries)
-20 to +55°C
-10 to +50°C
<±0.01% of rated load/°C
<±0.01% of rated load/°C
IP67
European Machinery Directive 2006/42/EC
Special ranges and sizes available
Can be supplied complete with shackles
T24-HA display, for multiple load cell system
Ruggedised Tablet PC, with bespoke software for datalogging,
Available Options
LCM Systems Ltd
Unit 15, Newport Business Park
Barry Way, Newport
Isle of Wight PO30 5GY UK
Tel: +44 (0)1983 249264
Fax: +44 (0)1983 249266
sales@lcmsystems.com
www.lcmsystems.com LCM SYSTEMS
Solutions in Load Cell TechnologySolutions in Load Cell Technology
reporting etc.
2. WLL Stainless Steel Wireless
Load Link
Dimensions
LCM SYSTEMS
Solutions in Load Cell TechnologySolutions in Load Cell Technology
B H
Weight
(kg)
5
12
25
35
50
100
220
260
320
350
400
460
78
85
102
122
140
200
D
22
32
43
42
50
68
27
37
53
52
59
84
3
5
9.7
13
20
43.5
Rating
(tonnes)
ØE
32.5
40
55
57.5
62.5
91
A
Resolution
(tonnes)
0.005
0.01
0.02
0.05
0.05
0.1
Battery
A
B C
D
ØE
78
50
G
155
180
210
235
275
278
C
H
82
92
103
102
110
120
G
Compartment
20 x 45º
20 x 45º
25 x 45º
30 x 45º
35 x 45º
50 x 45º
F
All dimensions are in mm
F
3. WLL Stainless Steel Wireless
Load Link
TYPE: WLL
Easily accessable batteries
www.lcmsystems.com
Due to continual product development, LCM Systems Ltd reserves
the right to alter product specifications without prior notice.
LCM SYSTEMS
Solutions in Load Cell TechnologySolutions in Load Cell Technology
Issue No. 1
Issue date: 07/11/2016
APPROVED
(unapproved if printed)
Storage Case
The WLL load link is supplied in a quality,
lockable moulded polyurethane
transit case that is highly durable and
impervious to most chemicals and
moisture. Its robust moulded construction
also means that it will not dent or rust.
The case also features pre-cut foam inserts
that ensure the load link and handheld
display remain securely in place.
5
12
25
35
50
100
6.5te Crosby G-2130
12te Crosby G-2130
25te Crosby G-2130
40te Crosby G-2140
55te Crosby G-2140
120te Crosby G-2140
Rating
(tonnes)
Crosby Load Shackles
Compatible Load Shackles
6.5te Green Pin G4163
12te Green Pin G4163
25te Green Pin G4163
40te Green Pin G5263
55te Green Pin G5263
120te Green Pin G5263
6.5te GN Rope H9
12te GN Rope H9
25te GN Rope H9
/
/
/
Van Beest Load Shackles GN Rope Load Shackles
5, 12, 25, 35
50
100
460 x 350 x 180mm
550 x 350 x 180mm
650 x 520 x 270mm
Load Link Rating
(tonnes)
Case Dimensions
No
Yes
Yes
With Wheels Weight (kg)
3.1
5.6
8.6