7150
3000
36600
2890 1360 4100 28250
1350
2000 1000
7150
12600 4600
2600 1600
1350
1750
7400 12000
36600
39503200
2000 2000 20001000
1350
2130
2100
3950
3000
2130
1000 5000 6550 6050 2100
20700
3200
7150
2130
2130
2100 1100 1100
1350
2000
2600
1350
2000
2600
30004150
7150
2100 18600
20700
1350
2000
2130
1100
2600 2600
Course:
Architectural Technology
ARC 600
Date:
12/12/14
Drawn by:
Daniel Palmer
Drawing No:
3
Drawing:
Elevations N/E/S/W
Scale:
1:100,1:200
Rev:
Sarah Radif
Project:
St. Mary's Healthcare Centre
North elevation
South elevation
East elevation
West elevation
Site plan
Site plan
2400 12001200
4800
12002400
6000
1200
700
1500
3000
2000
1800
1350
1800
2400
4800
950 2000 950
3900
4180
270
11005901100215024605251100
66
4260
300
950 2000 950
3900
950 2000 950
3900
950 2000 950
3900
950 2000 950
3900
950 2000 950
3900
2450
3280
2500
1800
1000
260
1000
390
1000100010001550
2200
20006002000650
950 2000 1000 900 2000 2700 625 1000 625
56003950
65020006002000750
950 2000 2000 2000 1050
3950
2250
6000
8000
14003003300
300
7900
67520006002000
675
5950
1650 2200 1590 2000 1310 2100 950
7950
1200
3000
44501100400
5950
2570
5900
2500
1500
1000mmGreenbeltaroundsite
4000 4000 4000 4000 4000 4000 4000 4000 1110 2890
1000500060006000
6000
1500
6200
6100
4400
1200
5000
6900
3700
3000
4200
5200
4000
8100
Course:
Architectural Technology
ARC 600
Date:
12/12/14
Drawn by:
Daniel Palmer
Drawing No:
1
Drawing:
Ground floor and fire plan
Scale:
1:100
Rev:
Sarah Radif
Project:
St. Mary's Healthcare Centre
Ground floor plan
Ground floor fire plan
848 2000 2305 850 2000 1050
290
2000
160
2500 395 2000
3900 2450 2790
200060020007005900
5950
4220
3480
5950
20006002000150020006002000
12000
2500
130
1000 960
278
1085 2000 815 875 2000
275
1700 2000
300
2230 2000 2000 2000
2360
2950 2725 2725 3900 3150 4000 9330
59001500
1500
2200 2200
360
1000
240
1000 510 1000 450 510 1000 450
3950
1960 1960
515 1000 1210
300
2000 425
4301
1800
1500
40001800
43001500
170011651165
3900
10002000900100020009002000 800
7950
360 1000
237
1700
3900
116511651625
12500
7000
5800
3400
8600
Gypframe GA1 Steel angle
Ancon PP21 wall movement tie
with debonding sleeve
Glasroc F Firecase (20mm) Refer to
manufacturer's recommendations
Celotex CW400
board insulation 25mm
Ancon SD21 wall ties
at 450mm centres
Brick external wall
Block internal wall
Ventilation gap in cavity
(50mm)
Gypframe GA1 Steel angle
Ancon PP21 wall movement tie
with debonding sleeve
Glasroc F Firecase (20mm)
Refer to manufacurer's
recommendations
Celotex CW400
board insulation (25mm)
Ancon SD21 wall ties
at 450mm centres
Block interal wall
Brick external wall
Column celotex foam fill
insulation (60mm)
Ventilation gap in cavity (50mm)
Gypframe GA1 Steel angle
Ancon PP21 wall movement tie
with debonding sleeve
Glasroc F Firecase (20mm)
Refer to manufacurer's
recommendations
Celotex CW400
board insulation (25mm)
Ancon SD21 wall ties
at 450mm centres
Block interal wall
Brick external wall
Column celotex foam fill
insulation (60mm)
Course:
Architectural Technology
ARC 600
Date:
12/12/14
Drawn by:
Daniel Palmer
Drawing No:
2
Drawing:
First floor and fire plan
Scale:
1:100, 1:10
Rev:
Sarah Radif
Project:
St. Mary's Healthcare Centre
Fire protection detail 1/2/3
First floor plan
First floor fire plan
Fire protection
Detail 1
Fire protection
Detail 2
Fire protection
Detail 3
Cavity Closer (100x35mm)
Block filler (15mm)
Parapet capping (by installer)
DPC
Kingspan Kooltherm K8 cavity board
Thickness: 50mm
U-value: 0.20 W/m2.k
Step flashing
Kingspan single-ply membrane
Kingspan roof barrier
Kingspan drainage layer
Kingspan filtration layer
Protection layer
Vapour Control Layer
Bonded cement sand screed (50mm)
Block (100x215mm)
TATA Steel Roofdek D100 structural steel roof decking (100mm).
Non-composite formwork.
Refer to manufacturer's and structural engineer's recommendations.
Steel secondary 'I' beam (200mmx300mm) (to structural engineer's details)
Ancon AMR masonry reinforcement
Dales S/S M12 threaded
bar and aluminium bosses -
self finish (used where loading require)
Refer to manufacturer's literature.
76.2 nose detail
Dales support arm, alum PPC (Finish: Timber
effect Polyester Powder Coating)
Dales 150mm Shadex blade alum PPC
(Finish: Timber effect Polyester
Powder Coating)
Substrate (to required depth)
Kingspan Thermaroof TR27 insulation (30mm)
Kingspan OPTIM-R insulation (50mm)
Kingspan OPTIM-R infill panel (50mm)
Ancon SAH-UO restraint with extended head.
Refer to manufacturer's recommendations
Catnic lintel CG90
100. (220mm)
Refer to manufacturer's recommendations.
(With DPC and insulation)
Plaster finish (12mm)
Olsen fixing bracket
Olsen packers
Olsen screw fixing Tremco illbruck Compriband TP600
Tremco illbruck FM230 Window seal foam
Tremco illbruck ME500 Duo
Flexible Window membrane
Trickle vent - Titon Trimvent 90 Hi Lift
Olsen Thermo 80 double-glazed window
Ancon HRT4 wall tie with
insulation retaining clip.
Refer to manufacturer's recommendations
(minimum embedment of 50mm)
Forbo Tessera Circulate floor tiles (7mm)
Unbonded cement sand screed (65mm)
Kingspan board insulation (25mm)
DPM
Kingspan Kooltherm K8 cavity board
Thickness: 50mm
U-value: 0.20 W/m2.k
DPC (At least 150mm above outside ground level)
Weep hole
Cavity closer (100x50mm)
Brick (102.5x65mm)
Block (100x215mm)
Silicone seal
on backing rod
Timber cill with drip (100mm)
Olsen screw fixing
Timber cill (18mm)
Block filler (100x115mm)
Timber skirting (15x150mm)
Tremco illbruck
Compriband TP600
Tremco illbruck
FM 230 Window seal foam
Tremco illbruck
ME500 Duo flexible
window membrane
Fixing brackets at head and cill to be
located 150-200mm from corners and at max
600mm centres
Fit packers at fixing bracket locations
level with locks/hinges and at mullions
Gyproc screw fixing QS25
Gyproc corner profile
15.5mm factory recessed edge
plasterboard frieze GFKD15
Gyptone cross tee (24mm)
Gyptone D1 Edge tiles (12.5mm)
Gyptone main beam (24mm)
Gyptone adjustable hanger
Glasroc F Firecase
(Refer to manufacturer's
recommendations)
Parapet drip
Structural concrete slab and pile foundation
to engineer's specification
Concrete slab installed on site (200mm depth)
Semi-extensive
green roof
Gypsum based
dot and dab adhesive (10mm)
Plaster finish (12.5mm)
Ventilation gap in cavity (50mm)
Designed outside ground level
Mortar (10mm)
Olsen window frame
30mm min overlap with insulation in
accordance with Accredited
Construction Details - Part L of the
Building Regulations
Steel primary 'I' beam
(200x350mm)
Marley Eternit perforated closure
Marley Eternit perforated closure
Marley Eternit Weatherboard cladding (10x190mm)
Marley Eternit Timber batten (38x50mm)
Expansion joint (3mm)
Marley Eternit end profile
Mastic bead
Compressible foam strip
Bonded cement sand screed (50mm)
Vapour Control layer
Protection layer
Min 25mm thick counter battens
fixed back to suit wind loads
50x30mm min timber battens
Marley Eternit Cedral Weatherboard
timber cladding (10x190mm)
50mm ringshank nails 5.5mm
diameter head min fixed through
tail of boards
Perforated closure
Marley Eternit start profile
Parapet capping
(to structural engineer's recommendations)
Kingspan single-ply membrane
Kingspan Thermaroof TR27 insulation (30mm)
Cavity Closer (35x100mm)
Kingspan OPTIM-R insulation (50mm)
DPC
Step flashing
Kingspan OPTIM-R infill panel (50mm)
Rytons weep hole duct (100x20mm)
Step flashing
Marley Eternit perforated closure
Glasroc F Firecase steel protection encasement (20mm)
(Refer to manufacturer's
recommendations)
Olsen window head frame
Catnic lintel CG90/100 (220mm)
Refer to manufacturer's recommendations
Ancon SAH-UO restraint with extended head.
Refer to manufacturer's recommendations
25mm ventilation gap
TATA Steel Roofdek D100 structural roof decking (100mm).
Non-composite formwork.
Refer to manufacturer's and structural engineer's
recommendations.
Concrete slab installed on site (150mm depth)
TATA Steel roofdek D100
structural roof decking (100mm).
Non-composite formwork.
Refer to manufacturer's and
structural engineers
recommendations
Drip
Block filler (160mm)
Marley Eternit cladding screw fixing
Marley Eternit Timber counter-batten (25x50mm)
Continuous insulation to prevent cold-bridging
Drainage outlet to external guttering (50mm).
Refer to manufacturer's recommendations
Marley Eternit start profile
Olsen Thermo 80
double-glazed window
Plaster finish (12mm)
Olsen screw fixing
Gyproc screw fixing QS25
Gyproc corner profile
15.5mm factory recessed edge
plasterboard frieze GFKD15
Gyptone cross tee (24mm)
Gyptone D1 Edge tiles (12.5mm)
Gyptone main beam (24mm)
Gyptone adjustable hanger
(providing void of 450mm)
Steel primary 'I' beam
(200x350mm)
Refer to construction detail 1
for green roof build-up
Glasroc F Firecase steel
protection encasement (20mm)
(Refer to manufacturer's
recommendations)
Gypsum based
dot and dab adhesive (10mm)
Olsen screw fixing
Timber cill (18mm)
Tremco illbruck
ME500 Duo flexible
window membrane
30mm min overlap with insulation in
accordance with Accredited
Construction Details - Part L of the
Building Regulations
Cavity closer (100x50mm)
Silicone seal on backing rod
Timber cill with drip (170mm)
Tremco illbruck
Compriband TP600
Tremco illbruck
FM 230 Window seal foam
Olsen window frame
Plasterboard finish (12.5mm)
Fixing brackets at head and cill to be
located 150-200mm from corners and at max
600mm centres
Fit packers at fixing bracket locations
level with locks/hinges and at mullions
Alumasc Harmer roof drainage
(300). Refer to manufacturer's
recommendations
15.5mm factory recessed edge
plasterboard frieze GFKD15
Glasroc F Firecase steel
protection encasement (20mm)
(Refer to manufacturer's
recommendations)
Ancon HRT4 wall tie with
insulation retaining clip.
Refer to manufacturer's
recommendations.
(minimum embedment of 50mm)
Kingspan Kooltherm K8 cavity board
Thickness: 50mm
U-value: 0.20 W/m2.k
26002600
2600
2600
Course:
Architectural Technology
ARC 600
Date:
12/12/14
Drawn by:
Daniel Palmer
Drawing No:
4
Drawing:
Construction details
Scale:
1:10, 1:100
Rev:
Sarah Radif
Project:
St. Mary's Healthcare Centre
Full building sections
Construction detail 1 Construction detail 2
Section A-A
Section B-B
dan palmer

dan palmer

  • 1.
    7150 3000 36600 2890 1360 410028250 1350 2000 1000 7150 12600 4600 2600 1600 1350 1750 7400 12000 36600 39503200 2000 2000 20001000 1350 2130 2100 3950 3000 2130 1000 5000 6550 6050 2100 20700 3200 7150 2130 2130 2100 1100 1100 1350 2000 2600 1350 2000 2600 30004150 7150 2100 18600 20700 1350 2000 2130 1100 2600 2600 Course: Architectural Technology ARC 600 Date: 12/12/14 Drawn by: Daniel Palmer Drawing No: 3 Drawing: Elevations N/E/S/W Scale: 1:100,1:200 Rev: Sarah Radif Project: St. Mary's Healthcare Centre North elevation South elevation East elevation West elevation Site plan Site plan
  • 2.
    2400 12001200 4800 12002400 6000 1200 700 1500 3000 2000 1800 1350 1800 2400 4800 950 2000950 3900 4180 270 11005901100215024605251100 66 4260 300 950 2000 950 3900 950 2000 950 3900 950 2000 950 3900 950 2000 950 3900 950 2000 950 3900 2450 3280 2500 1800 1000 260 1000 390 1000100010001550 2200 20006002000650 950 2000 1000 900 2000 2700 625 1000 625 56003950 65020006002000750 950 2000 2000 2000 1050 3950 2250 6000 8000 14003003300 300 7900 67520006002000 675 5950 1650 2200 1590 2000 1310 2100 950 7950 1200 3000 44501100400 5950 2570 5900 2500 1500 1000mmGreenbeltaroundsite 4000 4000 4000 4000 4000 4000 4000 4000 1110 2890 1000500060006000 6000 1500 6200 6100 4400 1200 5000 6900 3700 3000 4200 5200 4000 8100 Course: Architectural Technology ARC 600 Date: 12/12/14 Drawn by: Daniel Palmer Drawing No: 1 Drawing: Ground floor and fire plan Scale: 1:100 Rev: Sarah Radif Project: St. Mary's Healthcare Centre Ground floor plan Ground floor fire plan
  • 3.
    848 2000 2305850 2000 1050 290 2000 160 2500 395 2000 3900 2450 2790 200060020007005900 5950 4220 3480 5950 20006002000150020006002000 12000 2500 130 1000 960 278 1085 2000 815 875 2000 275 1700 2000 300 2230 2000 2000 2000 2360 2950 2725 2725 3900 3150 4000 9330 59001500 1500 2200 2200 360 1000 240 1000 510 1000 450 510 1000 450 3950 1960 1960 515 1000 1210 300 2000 425 4301 1800 1500 40001800 43001500 170011651165 3900 10002000900100020009002000 800 7950 360 1000 237 1700 3900 116511651625 12500 7000 5800 3400 8600 Gypframe GA1 Steel angle Ancon PP21 wall movement tie with debonding sleeve Glasroc F Firecase (20mm) Refer to manufacturer's recommendations Celotex CW400 board insulation 25mm Ancon SD21 wall ties at 450mm centres Brick external wall Block internal wall Ventilation gap in cavity (50mm) Gypframe GA1 Steel angle Ancon PP21 wall movement tie with debonding sleeve Glasroc F Firecase (20mm) Refer to manufacurer's recommendations Celotex CW400 board insulation (25mm) Ancon SD21 wall ties at 450mm centres Block interal wall Brick external wall Column celotex foam fill insulation (60mm) Ventilation gap in cavity (50mm) Gypframe GA1 Steel angle Ancon PP21 wall movement tie with debonding sleeve Glasroc F Firecase (20mm) Refer to manufacurer's recommendations Celotex CW400 board insulation (25mm) Ancon SD21 wall ties at 450mm centres Block interal wall Brick external wall Column celotex foam fill insulation (60mm) Course: Architectural Technology ARC 600 Date: 12/12/14 Drawn by: Daniel Palmer Drawing No: 2 Drawing: First floor and fire plan Scale: 1:100, 1:10 Rev: Sarah Radif Project: St. Mary's Healthcare Centre Fire protection detail 1/2/3 First floor plan First floor fire plan Fire protection Detail 1 Fire protection Detail 2 Fire protection Detail 3
  • 4.
    Cavity Closer (100x35mm) Blockfiller (15mm) Parapet capping (by installer) DPC Kingspan Kooltherm K8 cavity board Thickness: 50mm U-value: 0.20 W/m2.k Step flashing Kingspan single-ply membrane Kingspan roof barrier Kingspan drainage layer Kingspan filtration layer Protection layer Vapour Control Layer Bonded cement sand screed (50mm) Block (100x215mm) TATA Steel Roofdek D100 structural steel roof decking (100mm). Non-composite formwork. Refer to manufacturer's and structural engineer's recommendations. Steel secondary 'I' beam (200mmx300mm) (to structural engineer's details) Ancon AMR masonry reinforcement Dales S/S M12 threaded bar and aluminium bosses - self finish (used where loading require) Refer to manufacturer's literature. 76.2 nose detail Dales support arm, alum PPC (Finish: Timber effect Polyester Powder Coating) Dales 150mm Shadex blade alum PPC (Finish: Timber effect Polyester Powder Coating) Substrate (to required depth) Kingspan Thermaroof TR27 insulation (30mm) Kingspan OPTIM-R insulation (50mm) Kingspan OPTIM-R infill panel (50mm) Ancon SAH-UO restraint with extended head. Refer to manufacturer's recommendations Catnic lintel CG90 100. (220mm) Refer to manufacturer's recommendations. (With DPC and insulation) Plaster finish (12mm) Olsen fixing bracket Olsen packers Olsen screw fixing Tremco illbruck Compriband TP600 Tremco illbruck FM230 Window seal foam Tremco illbruck ME500 Duo Flexible Window membrane Trickle vent - Titon Trimvent 90 Hi Lift Olsen Thermo 80 double-glazed window Ancon HRT4 wall tie with insulation retaining clip. Refer to manufacturer's recommendations (minimum embedment of 50mm) Forbo Tessera Circulate floor tiles (7mm) Unbonded cement sand screed (65mm) Kingspan board insulation (25mm) DPM Kingspan Kooltherm K8 cavity board Thickness: 50mm U-value: 0.20 W/m2.k DPC (At least 150mm above outside ground level) Weep hole Cavity closer (100x50mm) Brick (102.5x65mm) Block (100x215mm) Silicone seal on backing rod Timber cill with drip (100mm) Olsen screw fixing Timber cill (18mm) Block filler (100x115mm) Timber skirting (15x150mm) Tremco illbruck Compriband TP600 Tremco illbruck FM 230 Window seal foam Tremco illbruck ME500 Duo flexible window membrane Fixing brackets at head and cill to be located 150-200mm from corners and at max 600mm centres Fit packers at fixing bracket locations level with locks/hinges and at mullions Gyproc screw fixing QS25 Gyproc corner profile 15.5mm factory recessed edge plasterboard frieze GFKD15 Gyptone cross tee (24mm) Gyptone D1 Edge tiles (12.5mm) Gyptone main beam (24mm) Gyptone adjustable hanger Glasroc F Firecase (Refer to manufacturer's recommendations) Parapet drip Structural concrete slab and pile foundation to engineer's specification Concrete slab installed on site (200mm depth) Semi-extensive green roof Gypsum based dot and dab adhesive (10mm) Plaster finish (12.5mm) Ventilation gap in cavity (50mm) Designed outside ground level Mortar (10mm) Olsen window frame 30mm min overlap with insulation in accordance with Accredited Construction Details - Part L of the Building Regulations Steel primary 'I' beam (200x350mm) Marley Eternit perforated closure Marley Eternit perforated closure Marley Eternit Weatherboard cladding (10x190mm) Marley Eternit Timber batten (38x50mm) Expansion joint (3mm) Marley Eternit end profile Mastic bead Compressible foam strip Bonded cement sand screed (50mm) Vapour Control layer Protection layer Min 25mm thick counter battens fixed back to suit wind loads 50x30mm min timber battens Marley Eternit Cedral Weatherboard timber cladding (10x190mm) 50mm ringshank nails 5.5mm diameter head min fixed through tail of boards Perforated closure Marley Eternit start profile Parapet capping (to structural engineer's recommendations) Kingspan single-ply membrane Kingspan Thermaroof TR27 insulation (30mm) Cavity Closer (35x100mm) Kingspan OPTIM-R insulation (50mm) DPC Step flashing Kingspan OPTIM-R infill panel (50mm) Rytons weep hole duct (100x20mm) Step flashing Marley Eternit perforated closure Glasroc F Firecase steel protection encasement (20mm) (Refer to manufacturer's recommendations) Olsen window head frame Catnic lintel CG90/100 (220mm) Refer to manufacturer's recommendations Ancon SAH-UO restraint with extended head. Refer to manufacturer's recommendations 25mm ventilation gap TATA Steel Roofdek D100 structural roof decking (100mm). Non-composite formwork. Refer to manufacturer's and structural engineer's recommendations. Concrete slab installed on site (150mm depth) TATA Steel roofdek D100 structural roof decking (100mm). Non-composite formwork. Refer to manufacturer's and structural engineers recommendations Drip Block filler (160mm) Marley Eternit cladding screw fixing Marley Eternit Timber counter-batten (25x50mm) Continuous insulation to prevent cold-bridging Drainage outlet to external guttering (50mm). Refer to manufacturer's recommendations Marley Eternit start profile Olsen Thermo 80 double-glazed window Plaster finish (12mm) Olsen screw fixing Gyproc screw fixing QS25 Gyproc corner profile 15.5mm factory recessed edge plasterboard frieze GFKD15 Gyptone cross tee (24mm) Gyptone D1 Edge tiles (12.5mm) Gyptone main beam (24mm) Gyptone adjustable hanger (providing void of 450mm) Steel primary 'I' beam (200x350mm) Refer to construction detail 1 for green roof build-up Glasroc F Firecase steel protection encasement (20mm) (Refer to manufacturer's recommendations) Gypsum based dot and dab adhesive (10mm) Olsen screw fixing Timber cill (18mm) Tremco illbruck ME500 Duo flexible window membrane 30mm min overlap with insulation in accordance with Accredited Construction Details - Part L of the Building Regulations Cavity closer (100x50mm) Silicone seal on backing rod Timber cill with drip (170mm) Tremco illbruck Compriband TP600 Tremco illbruck FM 230 Window seal foam Olsen window frame Plasterboard finish (12.5mm) Fixing brackets at head and cill to be located 150-200mm from corners and at max 600mm centres Fit packers at fixing bracket locations level with locks/hinges and at mullions Alumasc Harmer roof drainage (300). Refer to manufacturer's recommendations 15.5mm factory recessed edge plasterboard frieze GFKD15 Glasroc F Firecase steel protection encasement (20mm) (Refer to manufacturer's recommendations) Ancon HRT4 wall tie with insulation retaining clip. Refer to manufacturer's recommendations. (minimum embedment of 50mm) Kingspan Kooltherm K8 cavity board Thickness: 50mm U-value: 0.20 W/m2.k 26002600 2600 2600 Course: Architectural Technology ARC 600 Date: 12/12/14 Drawn by: Daniel Palmer Drawing No: 4 Drawing: Construction details Scale: 1:10, 1:100 Rev: Sarah Radif Project: St. Mary's Healthcare Centre Full building sections Construction detail 1 Construction detail 2 Section A-A Section B-B