SlideShare a Scribd company logo
1 of 8
Download to read offline
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
www.stahl.de Lighting E2/1 2013-09-25·EK00·III·en 
Series C-LUX 6108 / 6508 E2 
01907E00 
WebCode 6108A 
> Operating modes 
– non-maintained operation 
– non-maintained operation 
with switchable emergency 
light blocking 
> With continous operating test 
> For fluorescent lamps 8 W, 
d 16 mm, for two-pin holder G5 
> Suitable for wall and ceiling 
mounting 
> Can be fitted to order with 
emergency exit signs 
> Central locking 
Series C-LUX 6108 and 6508 compact emergency lighting fitting 
can be used for safety illumination, but also as information or 
emergency exit sign lights. 
*) only 6108 
ATEX / GOST* 
Zone 0 1 2 20 21 22 
6108: For use in x x x x 
6508: For use in x x x
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Selection table 
Version Lamps Emergency 
light duration 
test 
Battery 
capacity 
Emergency 
light 
operation 
time 
Order number Weight 
Ah h kg 
C-LUX 6108 for 
Zones 1, 2, 21, 22 
1 x 8 W with 2.5 1.5 6108/1081-8017-74-00 3.700 
C-LUX 6508 for 
Zones 2, 21, 22 
1 x 8 W with 2.5 1.5 6508/1081-8017-74-00 3.900 
Order number supplement 
Cable entries Standard: 
1 x Cable gland M25 x 1.5 
2 x Plugs M25 x 1.5 
6108/....-..1.-..-.. 
Special: 
Specify non-standard entries in writing 
6108/....-..9.-..-.. 
Emergency exit sign 
6108/....-....-..-60 
6108/....-....-..-61 
6108/....-....-..-62 
6108/....-....-..-87 
6108/....-....-..-91 
6108/....-....-..-71 
6108/....-....-..-81 
needed only when used as information lights or escape sign lights; 
With adhesive symbols positioned as follows: 
Mounting position 
Standard 
08481E00 
Special please specify other positions in writing 
Please specify emergency exit sign number (see below) 
Symbol complying with VGB 125, DIN 4844, DIN 5035; 
recognition distance e = 30 m; size 150 x 355 mm 
08483E00 
Colours Sign 
Background 
white 
green 
08482E00 
Colours Sign 
Background 
white 
green 
08484E00 
Colours Sign 
Background 
white 
green 
03018E00 
Colours Sign 
Background 
white 
green 
08485E00 
Colours Sign 
Background 
white 
green 
03206E00 
Colours Sign 
Background 
green 
white 
12617E00 
Colours Sign 
Background 
red 
white 
E2/2 Lighting 2013-09-25·EK00·III·en
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Order number supplement 
Emergency exit sign 
6108/....-....-..-92 
6108/....-....-..-72 
6108/....-....-..-82 
6108/....-....-..-90 
6108/....-....-..-70 
6108/....-....-..-80 
6108/....-....-..-93 
6108/....-....-..-73 
6108/....-....-..-83 
08486E00 
Colours Sign 
Background 
white 
green 
09020E00 
Colours Sign 
Background 
green 
white 
12618E00 
Colours Sign 
Background 
red 
white 
08487E00 
Colours Sign 
Background 
white 
green 
03203E00 
Colours Sign 
Background 
green 
white 
12616E00 
Colours Sign 
Background 
red 
white 
08488E00 
Colours Sign 
Background 
white 
green 
12615E00 
Colours Sign 
Background 
green 
white 
12619E00 
Colours Sign 
Background 
red 
white 
Note The light fittings are supplied without tubes and mounting material. 
These accessories must be ordered separately. 
Explosion protection 
Europe (ATEX) 
Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) 
Gas PTB 97 ATEX 2161 ASEV 99.1 10381.01 
E II 2 G EEx edm IIC T4 E II 3 G Ex nA IIC T4 (Zone 2) 
Dust LCIE 02 ATEX 6239 SEV 05 ATEX 0125 
E II 2 D IP66 T130°C E II 2 D IP66 T75°C 
Certificates and approvals 
Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) 
Certificates ATEX, China (CQST), 
Kazakhstan (GOST-K),Russia (GOST-R), 
Ukraine (GOST-U), Belarus (GOST-B), 
Tawain (ITRI) 
ATEX, China (CQST), Kazakhstan 
(GOST-K),Russia (GOST-R), 
Ukraine (GOST-U), Belarus (GOST-B), 
Tawain (ITRI) 
2013-09-25·EK00·III·en Lighting E2/3
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Technical data 
Electrical data 
Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) 
Nominal voltage AC: 220 ... 254 V, 50 ... 60 Hz 
AC: 110 ... 127 V, 50 ... 60 Hz possible on 
request 
AC: 220 ... 254 V, 50 ... 60 Hz 
AC: 110 ... 127 V, 50 ... 60 Hz possible on 
request 
Rated current 0.15 A 0.15 A 
Ballast Electronic ballast, single channel with integral 
emergency light electronics 
Electronic ballast, single channel with integral 
emergency light electronics 
Disconnection 
of light fitting on 
opening 
Central locking device with safety interlock; 
switch 8080 with N/C contacts; 
when central lock is opened, voltage to ballast 
is disconnected on both poles; 
a safety interlock in switching mechanism 
prevents fitting from being reconnected while 
cover and central lock are open. 
No switching-off when opening light fitting 
Faulty lamp If lamp is faulty power supply is automatically 
switched off by electronic ballast 
If lamp is faulty power supply is automatically 
switched off by electronic ballast 
Luminous Characteristics 
Lamps 1 x 8 W; two-pin fluorescent lamps, 8 W, d 16 mm, for G5 holder 
Light guides Reflector painted white; 
Cover with prism structure, providing directed light from the fitting 
Operating modes Mains operation for general lighting or as information lights; 
Emergency operation: fed from battery-set built into emergency lighting fitting when used for 
escape route illumination or as emergency exit sign lighting. 
Ambient conditions 
Charging -5 ... +50 °C 
Normal mode -20 ... +50 °C 
Mechanical data 
Degree of protection IP66 (IP64 with breather 8162) 
Protection class I(with internal PE connection terminal) 
Material 
Enclosure glass fibre reinforced polyester resin, colour: white, similar to RAL 9010 
Lamp cover Polycarbonate 
Seal Polyurethane; foamed into cover 
Cover options 
Mounting / installation 
Cable entry 
Central locking using socket spanner M8 / SW 13; cover hinged for access 
central lock cover hinge 
Standard 1 cable entry 8161 in plastic M25 x 1.5 and 2 plugs 8290 in plastic, M25 x 1.5 
(enclosed) 
Graphic 
Special version Other entries in moulded plastic or metal are available to order, details available on request 
Connection 
Terminal block in Polyamide with terminal cover 
Marking L´, L, N, PE 
Terminal size 2 x 4 mm2 for solid cores 
2 x 2.5 mm2 for flexible cores 
08478E02 
08479E02 
E2/4 Lighting 2013-09-25·EK00·III·en
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Technical data 
Installation notes 
Looping through of 
cables 
2 leads can be connected to each terminal on the input side, 
making fittings suitable for looped connection. 
Mounting Can be wall- or ceiling-mounted 
Emergency light electronics 
Design Incorporated in one housing with electronic ballast unit 
Operating modes Emergency lighting electronics are available: 
08480E00 
with automatic emergency light duration test; 
in maintained operation or maintained operation with switchable emergency lighting blocking. 
Self-test function The emergency light fitting is available with self-test function. The built-in self-test functions are 
activated as soon as light is connected to mains and automatically repeated after pre-set time has 
elapsed. 
Functional test Weekly test of emergency light function; battery and lamp faults are recognized and indicated via 
red LED. 
Light duration test of the 
emergency lighting 
Testing of battery capacity at intervalls of 12 months; operating of fitting in emergency light mode 
for 2.3rd of rated operating time. If the fitting is switches off by the discharge protection before 
time has elapsed. Battery cannot be used longer for emergency operation. Fault is indicated via 
red LED. 
Function indicators 
1 LED red and 1 LED green, 
incorporated in reflector; can be seen from outside throught cover 
LED Indication Function 
Green On Light fitting okay; charging current is supplied 
Blinking Light fitting okay; function test or continous on 
test is running 
Red On Battery error; not connection to the battery or 
battery completely discharged 
Blinking Battery error; battery has not enough capacity 
Flashing 1:10 Lamp error; lamp is out of order or lamp is end 
of life 
Green / 
Red 
Blinking Emergency light function is jam by external 
switch 
Blinking 1 s ON 
1 s OFF 
Flashing 0.25 s ON 
1.75 s OFF 
Battery charge intelligent battery management system, microprocessor-based (on-load time of max. 14 h) deep-discharging 
protection to the avoidance of cell pol reversal 
Emergency light service 
time 
Battery capacity 2.5 Ah 
Emergency light operation time 1.5 h / 3.0 h 
2013-09-25·EK00·III·en Lighting E2/5
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Technical data 
Operating modes 
Switchover voltage 
Lighting power in case of 
emergency light mode 
On delivery light fitting is wired for maintained operation; 
by removing the jumper between terminals 9 and 10 and connecting external switch F, 
the fitting is converted to maintained operation with switchable emergency lighting. 
Terminals emergency 
lighting electronics 
Jumper 
Maintained operation 
Terminals emergency 
lighting electronics 
Maintained operation with 
switchable emergency lighting 
External 
switch F 
Functions 
Maintained operation 
On failure of supply to general lighting, fitting is supplied from the battery, 
irrespective of the light switch position 
Maintained operation with switchable emergency lighting 
On failure of power supply to general lighting, fitting switches to emergency lighting operation only 
if external switch F is closed. To switch emergency lighting centrally to „Ready“ or „Not ready“, 
e. g. depending on plant operation times. 
The external switch has a potential-free NO contact. 
Note: 
- line wiring max. 30 emergency light fittings for 1 external switch; 
- point to point wiring 50 emergency light fittings for 1 external switch 
- length of cable max. 500 m with wire 1.5mm2 
from mains to battery operation at U < 0.74 x UN 
from battery to mains operation at U > 0.80 x UN 
1.5 h / 70 % 
3.0 h / 30 % 
Battery set 
08711E02 08712E02 
Version NICd battery, gas tight, built into light fitting 
Operating voltage 6 V 
Capacity 2.5 Ah 
Replacing the battery set When the central lock is opened the battery set is de-energized; it can be removed from the 
housing by unplugging its removable contact. 
Emergency exit signs 
Use for information and escape sign fittings 
Material Foil, self-adhesive, printed with various pictograms in different colours 
Recognition distance e = 30 m 
Mounting Foil is stuck to cover externally 
Options The various types of adhesive foil which can be supplied are detailed in table "Accessories and 
Spare Parts" 
Accessories and spare parts 
Designation Figure Description Art. no. Weight 
kg 
Fluorescent lamps 
04936E00 
8 W, d 16 mm, for two-pin G5 holder 
119045 0.415 
Socket spanner 
05321E00 
Colour of 
light 
Light flux 
cool white 450 Im 10 pcs 
M8 / wrench size 13; 
to open/close the central locking 
140486 0.126 
E2/6 Lighting 2013-09-25·EK00·III·en
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
E2 
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Accessories and spare parts 
Designation Figure Description Art. no. Weight 
Adapter plate 
05755E00 
for use together with metal cable glands; the metal cable 
glands are integrated in the earthing system via adapter 
plates 
kg 
115826 0.060 
115828 0.060 
Emergency exit sign 
08483E00 
113182 0.015 
08482E00 
113183 0.015 
08484E00 
113184 0.015 
03018E00 
113206 0.015 
08485E00 
113210 0.015 
03206E00 
113193 0.015 
12617E00 
113200 0.015 
08486E00 
113211 0.015 
09020E00 
113194 0.015 
12618E00 
113201 0.015 
08487E00 
113209 0.015 
03203E00 
113192 0.015 
12616E00 
113199 0.015 
08488E00 
113212 0.015 
12615E00 
113195 0.015 
12619E00 
113202 0.015 
2 x M20 x 1.5 1 piece 
2 x M25 x 1.5 1 piece 
white green 1 pc 
white green 1 pc 
white green 1 pc 
white green 1 pc 
white green 1 pc 
green white 1 pc 
red white 1 pc 
white green 1 pc 
green white 1 pc 
red white 1 pc 
white green 1 pc 
green white 1 pc 
red white 1 pc 
white green 1 pc 
green white 1 pc 
red white 1 pc 
2013-09-25·EK00·III·en Lighting E2/7
Compact Emergency Light Fittings 
Series C-LUX 6108 / 6508 
Accessories and spare parts 
Designation Figure Description Art. no. Weight 
Diffuser 
05704E00 
kg 
for light fitting 8 W 119044 0.250 
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 
7 119 
04293E00 
Additional dimensions for cable 
entries 8161 and plugs 8290 
04295E00 
355 
150 
Emergency exit sign 
9 425 11 
445 
181 a 
4 
R3,5 
a (mm) 
8161 M25 x 1.5 32 
8290 M25 x 1.5 6 
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. 
The illustrations cannot be considered binding. 
E2/8 Lighting 2013-09-25·EK00·III·en

More Related Content

What's hot

Mecanismo pulsador de persiana 8144 Niessen
Mecanismo pulsador de persiana 8144 NiessenMecanismo pulsador de persiana 8144 Niessen
Mecanismo pulsador de persiana 8144 NiessenInhogar
 
Capacitación en Sistemas de Citofonía BTICINO
Capacitación en Sistemas de Citofonía BTICINOCapacitación en Sistemas de Citofonía BTICINO
Capacitación en Sistemas de Citofonía BTICINOSodimac-Constructor
 
Instructions SWAROVSKI Z6 | Optics Trade
Instructions SWAROVSKI Z6 | Optics TradeInstructions SWAROVSKI Z6 | Optics Trade
Instructions SWAROVSKI Z6 | Optics TradeOptics-Trade
 
Nota técnica n1 ensayo de materiales dieléctricos ver 1 2
Nota técnica n1 ensayo de materiales dieléctricos ver 1 2Nota técnica n1 ensayo de materiales dieléctricos ver 1 2
Nota técnica n1 ensayo de materiales dieléctricos ver 1 2Leonardo O Guarco
 
Mecanismo interruptor de persiana 8144.1 Niessen
Mecanismo interruptor de persiana 8144.1 NiessenMecanismo interruptor de persiana 8144.1 Niessen
Mecanismo interruptor de persiana 8144.1 NiessenInhogar
 
2301 manual (v7.0 - 80384 a) (1) gefran
2301   manual (v7.0 - 80384 a) (1) gefran2301   manual (v7.0 - 80384 a) (1) gefran
2301 manual (v7.0 - 80384 a) (1) gefranDarío Falquéz
 
Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons
Clifford & Snell Hazardous Area Explosion Proof Sounders & BeaconsClifford & Snell Hazardous Area Explosion Proof Sounders & Beacons
Clifford & Snell Hazardous Area Explosion Proof Sounders & BeaconsThorne & Derrick International
 
Centro de carga monofasicos y trifasicos
Centro de carga monofasicos y trifasicosCentro de carga monofasicos y trifasicos
Centro de carga monofasicos y trifasicosOswaldoRobledo2
 
11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...
11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...
11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...Thorne & Derrick International
 
Interruptor de un polo GW20571
Interruptor de un polo GW20571Interruptor de un polo GW20571
Interruptor de un polo GW20571Inhogar
 
Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...
Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...
Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...Thorne & Derrick International
 
Tecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdf
Tecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdfTecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdf
Tecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdfssuser4a5bad
 
LTC3108 – Ultralow Voltage Step-Up Converter and Power Manager
LTC3108 – Ultralow Voltage Step-Up Converter and Power ManagerLTC3108 – Ultralow Voltage Step-Up Converter and Power Manager
LTC3108 – Ultralow Voltage Step-Up Converter and Power ManagerPremier Farnell
 
Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors Thorne & Derrick International
 
Schneider KNX PPT.ppt
Schneider KNX PPT.pptSchneider KNX PPT.ppt
Schneider KNX PPT.pptSayedAlameen
 

What's hot (20)

Mecanismo pulsador de persiana 8144 Niessen
Mecanismo pulsador de persiana 8144 NiessenMecanismo pulsador de persiana 8144 Niessen
Mecanismo pulsador de persiana 8144 Niessen
 
Capacitación en Sistemas de Citofonía BTICINO
Capacitación en Sistemas de Citofonía BTICINOCapacitación en Sistemas de Citofonía BTICINO
Capacitación en Sistemas de Citofonía BTICINO
 
Instructions SWAROVSKI Z6 | Optics Trade
Instructions SWAROVSKI Z6 | Optics TradeInstructions SWAROVSKI Z6 | Optics Trade
Instructions SWAROVSKI Z6 | Optics Trade
 
Nota técnica n1 ensayo de materiales dieléctricos ver 1 2
Nota técnica n1 ensayo de materiales dieléctricos ver 1 2Nota técnica n1 ensayo de materiales dieléctricos ver 1 2
Nota técnica n1 ensayo de materiales dieléctricos ver 1 2
 
Mecanismo interruptor de persiana 8144.1 Niessen
Mecanismo interruptor de persiana 8144.1 NiessenMecanismo interruptor de persiana 8144.1 Niessen
Mecanismo interruptor de persiana 8144.1 Niessen
 
2301 manual (v7.0 - 80384 a) (1) gefran
2301   manual (v7.0 - 80384 a) (1) gefran2301   manual (v7.0 - 80384 a) (1) gefran
2301 manual (v7.0 - 80384 a) (1) gefran
 
SLC
SLCSLC
SLC
 
Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons
Clifford & Snell Hazardous Area Explosion Proof Sounders & BeaconsClifford & Snell Hazardous Area Explosion Proof Sounders & Beacons
Clifford & Snell Hazardous Area Explosion Proof Sounders & Beacons
 
Centro de carga monofasicos y trifasicos
Centro de carga monofasicos y trifasicosCentro de carga monofasicos y trifasicos
Centro de carga monofasicos y trifasicos
 
11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...
11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...
11kV Heat Shrink Cable Terminations - Prysmian HIT3XB11 3 Core 35-70sqmm 11kV...
 
Interruptor de un polo GW20571
Interruptor de un polo GW20571Interruptor de un polo GW20571
Interruptor de un polo GW20571
 
Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...
Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...
Hazardous Area Zones & Explosion Protection - An Overview of Potentially Expl...
 
NFS-320
NFS-320NFS-320
NFS-320
 
Tecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdf
Tecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdfTecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdf
Tecnicas Unidad Didactica 2 (Curso 22-23) Alumnos.pdf
 
Manual power flex 40 en
Manual power flex 40 enManual power flex 40 en
Manual power flex 40 en
 
NFS2-3030
NFS2-3030NFS2-3030
NFS2-3030
 
PPT Elegir punta_JBC
PPT Elegir punta_JBCPPT Elegir punta_JBC
PPT Elegir punta_JBC
 
LTC3108 – Ultralow Voltage Step-Up Converter and Power Manager
LTC3108 – Ultralow Voltage Step-Up Converter and Power ManagerLTC3108 – Ultralow Voltage Step-Up Converter and Power Manager
LTC3108 – Ultralow Voltage Step-Up Converter and Power Manager
 
Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors
 
Schneider KNX PPT.ppt
Schneider KNX PPT.pptSchneider KNX PPT.ppt
Schneider KNX PPT.ppt
 

Similar to Stahl C-LUX 6108 Compact Emergency Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Lighting

Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous AreaStahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous AreaThorne & Derrick International
 
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...Thorne & Derrick International
 
Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...
Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...
Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...Thorne & Derrick International
 
Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...
Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...
Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...Thorne & Derrick International
 
Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...
Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...
Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...Thorne & Derrick International
 
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)Thorne & Derrick International
 
Cataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardCataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardDien Ha The
 
Cataloge ge 2.industrial components_dienhathe.com-2_entelli_guard
Cataloge ge 2.industrial components_dienhathe.com-2_entelli_guardCataloge ge 2.industrial components_dienhathe.com-2_entelli_guard
Cataloge ge 2.industrial components_dienhathe.com-2_entelli_guardDien Ha The
 
Cataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardCataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardThuan Kieu
 
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) LightingAbtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) LightingThorne & Derrick International
 
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...Thorne & Derrick International
 
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...Thorne & Derrick International
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)Thorne & Derrick International
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaThorne & Derrick International
 
Stahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)Thorne & Derrick International
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)Thorne & Derrick International
 
Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)
Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)
Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)Thorne & Derrick International
 
Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...
Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...
Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...Thorne & Derrick International
 
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 

Similar to Stahl C-LUX 6108 Compact Emergency Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Lighting (20)

Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous AreaStahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
 
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
 
Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...
Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...
Stahl ECOLUX 6608 Economy Emergency Light Fitting For FluorescentLamps - ATEX...
 
Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...
Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...
Stahl ECOLUX 6608 Emergency Light Litting For Fluorescent Lamps - ATEX Zone 1...
 
Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...
Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...
Stahl 6008 Emergency Light Fitting For Fluorescent Lamps - ATEX Zone 1 Zone 2...
 
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
 
Cataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardCataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guard
 
Cataloge ge 2.industrial components_dienhathe.com-2_entelli_guard
Cataloge ge 2.industrial components_dienhathe.com-2_entelli_guardCataloge ge 2.industrial components_dienhathe.com-2_entelli_guard
Cataloge ge 2.industrial components_dienhathe.com-2_entelli_guard
 
Cataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardCataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guard
 
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) LightingAbtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
 
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
 
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
 
Stahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_5 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
 
Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)
Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)
Zone 1 ATEX Lighting Fluorescent Luminaires - Hadar HDL100 (2 x 18Watt Lamps)
 
Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...
Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...
Stahl 6147 Hand Lamp With Mains Connection - ATEX Zone 1 Zone 2 Hazardous Are...
 
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
 

More from Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 

More from Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

Recently uploaded

Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure servicePooja Nehwal
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Igalia
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...shyamraj55
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...HostedbyConfluent
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 

Recently uploaded (20)

Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 

Stahl C-LUX 6108 Compact Emergency Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Lighting

  • 1. E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 Compact Emergency Light Fittings Series C-LUX 6108 / 6508 www.stahl.de Lighting E2/1 2013-09-25·EK00·III·en Series C-LUX 6108 / 6508 E2 01907E00 WebCode 6108A > Operating modes – non-maintained operation – non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5 > Suitable for wall and ceiling mounting > Can be fitted to order with emergency exit signs > Central locking Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for safety illumination, but also as information or emergency exit sign lights. *) only 6108 ATEX / GOST* Zone 0 1 2 20 21 22 6108: For use in x x x x 6508: For use in x x x
  • 2. Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Selection table Version Lamps Emergency light duration test Battery capacity Emergency light operation time Order number Weight Ah h kg C-LUX 6108 for Zones 1, 2, 21, 22 1 x 8 W with 2.5 1.5 6108/1081-8017-74-00 3.700 C-LUX 6508 for Zones 2, 21, 22 1 x 8 W with 2.5 1.5 6508/1081-8017-74-00 3.900 Order number supplement Cable entries Standard: 1 x Cable gland M25 x 1.5 2 x Plugs M25 x 1.5 6108/....-..1.-..-.. Special: Specify non-standard entries in writing 6108/....-..9.-..-.. Emergency exit sign 6108/....-....-..-60 6108/....-....-..-61 6108/....-....-..-62 6108/....-....-..-87 6108/....-....-..-91 6108/....-....-..-71 6108/....-....-..-81 needed only when used as information lights or escape sign lights; With adhesive symbols positioned as follows: Mounting position Standard 08481E00 Special please specify other positions in writing Please specify emergency exit sign number (see below) Symbol complying with VGB 125, DIN 4844, DIN 5035; recognition distance e = 30 m; size 150 x 355 mm 08483E00 Colours Sign Background white green 08482E00 Colours Sign Background white green 08484E00 Colours Sign Background white green 03018E00 Colours Sign Background white green 08485E00 Colours Sign Background white green 03206E00 Colours Sign Background green white 12617E00 Colours Sign Background red white E2/2 Lighting 2013-09-25·EK00·III·en
  • 3. E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Order number supplement Emergency exit sign 6108/....-....-..-92 6108/....-....-..-72 6108/....-....-..-82 6108/....-....-..-90 6108/....-....-..-70 6108/....-....-..-80 6108/....-....-..-93 6108/....-....-..-73 6108/....-....-..-83 08486E00 Colours Sign Background white green 09020E00 Colours Sign Background green white 12618E00 Colours Sign Background red white 08487E00 Colours Sign Background white green 03203E00 Colours Sign Background green white 12616E00 Colours Sign Background red white 08488E00 Colours Sign Background white green 12615E00 Colours Sign Background green white 12619E00 Colours Sign Background red white Note The light fittings are supplied without tubes and mounting material. These accessories must be ordered separately. Explosion protection Europe (ATEX) Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) Gas PTB 97 ATEX 2161 ASEV 99.1 10381.01 E II 2 G EEx edm IIC T4 E II 3 G Ex nA IIC T4 (Zone 2) Dust LCIE 02 ATEX 6239 SEV 05 ATEX 0125 E II 2 D IP66 T130°C E II 2 D IP66 T75°C Certificates and approvals Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) Certificates ATEX, China (CQST), Kazakhstan (GOST-K),Russia (GOST-R), Ukraine (GOST-U), Belarus (GOST-B), Tawain (ITRI) ATEX, China (CQST), Kazakhstan (GOST-K),Russia (GOST-R), Ukraine (GOST-U), Belarus (GOST-B), Tawain (ITRI) 2013-09-25·EK00·III·en Lighting E2/3
  • 4. Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Technical data Electrical data Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) Nominal voltage AC: 220 ... 254 V, 50 ... 60 Hz AC: 110 ... 127 V, 50 ... 60 Hz possible on request AC: 220 ... 254 V, 50 ... 60 Hz AC: 110 ... 127 V, 50 ... 60 Hz possible on request Rated current 0.15 A 0.15 A Ballast Electronic ballast, single channel with integral emergency light electronics Electronic ballast, single channel with integral emergency light electronics Disconnection of light fitting on opening Central locking device with safety interlock; switch 8080 with N/C contacts; when central lock is opened, voltage to ballast is disconnected on both poles; a safety interlock in switching mechanism prevents fitting from being reconnected while cover and central lock are open. No switching-off when opening light fitting Faulty lamp If lamp is faulty power supply is automatically switched off by electronic ballast If lamp is faulty power supply is automatically switched off by electronic ballast Luminous Characteristics Lamps 1 x 8 W; two-pin fluorescent lamps, 8 W, d 16 mm, for G5 holder Light guides Reflector painted white; Cover with prism structure, providing directed light from the fitting Operating modes Mains operation for general lighting or as information lights; Emergency operation: fed from battery-set built into emergency lighting fitting when used for escape route illumination or as emergency exit sign lighting. Ambient conditions Charging -5 ... +50 °C Normal mode -20 ... +50 °C Mechanical data Degree of protection IP66 (IP64 with breather 8162) Protection class I(with internal PE connection terminal) Material Enclosure glass fibre reinforced polyester resin, colour: white, similar to RAL 9010 Lamp cover Polycarbonate Seal Polyurethane; foamed into cover Cover options Mounting / installation Cable entry Central locking using socket spanner M8 / SW 13; cover hinged for access central lock cover hinge Standard 1 cable entry 8161 in plastic M25 x 1.5 and 2 plugs 8290 in plastic, M25 x 1.5 (enclosed) Graphic Special version Other entries in moulded plastic or metal are available to order, details available on request Connection Terminal block in Polyamide with terminal cover Marking L´, L, N, PE Terminal size 2 x 4 mm2 for solid cores 2 x 2.5 mm2 for flexible cores 08478E02 08479E02 E2/4 Lighting 2013-09-25·EK00·III·en
  • 5. E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Technical data Installation notes Looping through of cables 2 leads can be connected to each terminal on the input side, making fittings suitable for looped connection. Mounting Can be wall- or ceiling-mounted Emergency light electronics Design Incorporated in one housing with electronic ballast unit Operating modes Emergency lighting electronics are available: 08480E00 with automatic emergency light duration test; in maintained operation or maintained operation with switchable emergency lighting blocking. Self-test function The emergency light fitting is available with self-test function. The built-in self-test functions are activated as soon as light is connected to mains and automatically repeated after pre-set time has elapsed. Functional test Weekly test of emergency light function; battery and lamp faults are recognized and indicated via red LED. Light duration test of the emergency lighting Testing of battery capacity at intervalls of 12 months; operating of fitting in emergency light mode for 2.3rd of rated operating time. If the fitting is switches off by the discharge protection before time has elapsed. Battery cannot be used longer for emergency operation. Fault is indicated via red LED. Function indicators 1 LED red and 1 LED green, incorporated in reflector; can be seen from outside throught cover LED Indication Function Green On Light fitting okay; charging current is supplied Blinking Light fitting okay; function test or continous on test is running Red On Battery error; not connection to the battery or battery completely discharged Blinking Battery error; battery has not enough capacity Flashing 1:10 Lamp error; lamp is out of order or lamp is end of life Green / Red Blinking Emergency light function is jam by external switch Blinking 1 s ON 1 s OFF Flashing 0.25 s ON 1.75 s OFF Battery charge intelligent battery management system, microprocessor-based (on-load time of max. 14 h) deep-discharging protection to the avoidance of cell pol reversal Emergency light service time Battery capacity 2.5 Ah Emergency light operation time 1.5 h / 3.0 h 2013-09-25·EK00·III·en Lighting E2/5
  • 6. Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Technical data Operating modes Switchover voltage Lighting power in case of emergency light mode On delivery light fitting is wired for maintained operation; by removing the jumper between terminals 9 and 10 and connecting external switch F, the fitting is converted to maintained operation with switchable emergency lighting. Terminals emergency lighting electronics Jumper Maintained operation Terminals emergency lighting electronics Maintained operation with switchable emergency lighting External switch F Functions Maintained operation On failure of supply to general lighting, fitting is supplied from the battery, irrespective of the light switch position Maintained operation with switchable emergency lighting On failure of power supply to general lighting, fitting switches to emergency lighting operation only if external switch F is closed. To switch emergency lighting centrally to „Ready“ or „Not ready“, e. g. depending on plant operation times. The external switch has a potential-free NO contact. Note: - line wiring max. 30 emergency light fittings for 1 external switch; - point to point wiring 50 emergency light fittings for 1 external switch - length of cable max. 500 m with wire 1.5mm2 from mains to battery operation at U < 0.74 x UN from battery to mains operation at U > 0.80 x UN 1.5 h / 70 % 3.0 h / 30 % Battery set 08711E02 08712E02 Version NICd battery, gas tight, built into light fitting Operating voltage 6 V Capacity 2.5 Ah Replacing the battery set When the central lock is opened the battery set is de-energized; it can be removed from the housing by unplugging its removable contact. Emergency exit signs Use for information and escape sign fittings Material Foil, self-adhesive, printed with various pictograms in different colours Recognition distance e = 30 m Mounting Foil is stuck to cover externally Options The various types of adhesive foil which can be supplied are detailed in table "Accessories and Spare Parts" Accessories and spare parts Designation Figure Description Art. no. Weight kg Fluorescent lamps 04936E00 8 W, d 16 mm, for two-pin G5 holder 119045 0.415 Socket spanner 05321E00 Colour of light Light flux cool white 450 Im 10 pcs M8 / wrench size 13; to open/close the central locking 140486 0.126 E2/6 Lighting 2013-09-25·EK00·III·en
  • 7. E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Accessories and spare parts Designation Figure Description Art. no. Weight Adapter plate 05755E00 for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates kg 115826 0.060 115828 0.060 Emergency exit sign 08483E00 113182 0.015 08482E00 113183 0.015 08484E00 113184 0.015 03018E00 113206 0.015 08485E00 113210 0.015 03206E00 113193 0.015 12617E00 113200 0.015 08486E00 113211 0.015 09020E00 113194 0.015 12618E00 113201 0.015 08487E00 113209 0.015 03203E00 113192 0.015 12616E00 113199 0.015 08488E00 113212 0.015 12615E00 113195 0.015 12619E00 113202 0.015 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece white green 1 pc white green 1 pc white green 1 pc white green 1 pc white green 1 pc green white 1 pc red white 1 pc white green 1 pc green white 1 pc red white 1 pc white green 1 pc green white 1 pc red white 1 pc white green 1 pc green white 1 pc red white 1 pc 2013-09-25·EK00·III·en Lighting E2/7
  • 8. Compact Emergency Light Fittings Series C-LUX 6108 / 6508 Accessories and spare parts Designation Figure Description Art. no. Weight Diffuser 05704E00 kg for light fitting 8 W 119044 0.250 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 7 119 04293E00 Additional dimensions for cable entries 8161 and plugs 8290 04295E00 355 150 Emergency exit sign 9 425 11 445 181 a 4 R3,5 a (mm) 8161 M25 x 1.5 32 8290 M25 x 1.5 6 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. E2/8 Lighting 2013-09-25·EK00·III·en