Manufacturing and Supplying a pristine range of Submersible Pumps. Our array of products comprises Electric Motors Three Phase, Electric Motors Single Phase, V3 Submersible Pump, Monoset Submersible Pump, Open Well Submersible Pump, V6 Submersible Pumps, Self Priming Pump, V4 Electric Motors. These products are highly demanded by the clients for their long functional life, excellent efficiency, sturdy construction and power saving features.
3. ®
AMIT
Special Features :
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
Fully rewindable and water lubricated motor with stainless steel body.
20% to 35% less power consumption.
50 feet head per stage in V-6 submersible pump set.
Water discharge up to 1500 Lpm.
Winder voltage fluctuation capacity of motor.
Very good wear resistance of components to give longer life to pump set and results higher
efficiency.
Higher capacity of thrust bearing, which gives longer life to motor as well as its winding.
Durability of components, strict quality control & computerized testing set up gives right
product to the customer.
V-6 SS Pump Bowl made from SS investment casting & impeller also made from molded steel
makes pump maintenance free.
V-6 CI pump impeller material - Fibreglass Reinforced Thermo Plastic (FRTP) with steel
molded neck righ ISI approved smoothly in sndy water also.
Wide range of selection to enrich your requirements for single phase 0.5 to 3.0 HP up to depth
800 feet & Three Phase 3.0 to 20 HP up to depth 1200 feet.
We provide one year warranty against any manufacturing defect.
Terms & Conditions of Business :
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
This price list cancels our all previous price list.
Price are subject to change without any previous notice.
Once goods sold will not be taken back or replaced under any circumstances.
Supply period of material would be 3-4 days from the date of order
receipt/confirm.
Packing charges are extra for wooden boxes minimum Rs. 300/- each.
We are not responsible for any losses or any breakages during transportation.
We do not allow any credit facility, payment must be in advance or documents
through Nationalized Bank only.
In the case of replacement / Re-freshment, all the transportation charges will
be paid by dealer, and all the charges of short received parts will be debited to
dealer’s account.
If payment is not received within 30 days from the date of bill interest @ 24%
p.a. will be charged after 30 days from date of bill.
If bank document does not retired within 45 days from the date of bill, same
will be recalled thereafter immediately and materials will be re-booked all
expenses in this regard shall be debited to dealer’s / distributor’s account and
shall be deducted from dealer’s / distributor’s deposit / advance.
ST/CST or any other Taxes charged extra as applicable.
Price are Ex-Factory F.O.R. Rajkot. (Guj.)
All disputers are subject to RAJKOT Jurisdiction only.
- 16 -
4. Information & Suggestion :
Dealers / Distributors are realized to select proper model in order to get best results at site,
for that they must take into consideration the following points :
w
w
w
w
w
w
w
Position of voltage at site. if single phase then stability of neutral.
Starter conditions and proper relay tripping.
Maximum lower level of water in the well.
Real requirements of water as per customer need.
Whether there is problem of sand in borewell / openwell.
Whether the quality and size of delivery pipes are proper or not.
Actual irrigation area of land.
The level of head and discharge given in the Performance / Price list are according to the
ideal conditions during testing. Practically the head and discharge may be less than given
in the performance due to following reasons.
1. Frequency Loss :
If the frequency (HZ) is less than 50 i.e. if ti is 48, 49 then the speed decreases by 60
R.P.M. at loss of 1 freq.
2. Voltage Loss :
Result obtained is less due to less voltages.
3. Delivery Pipe Loss :
If the delivery pipe found smaller & rough then pipe loss may occurs which result in
reduction of discharge.
4. If the cable joints are not perfectly waterproof then the result may decrease.