SlideShare a Scribd company logo
evas-2506 installation
instructions
foreword
EAVS-2506 is an alarm video integrated host using H.265
video compression. The host supports 6-way POE high-
definition network video access, and supports multiple wired
and wireless and bus defense zones. Built-in 2G/4G network
module and TCP/IP network module, dual network
communication, stable and reliable performance.
It has special functions such as high-definition monitoring,
intelligent anti-theft, two-way intercom, intelligent home
appliances, remote control, and centralized management.
It is widely used in residential areas, villas, shops, chain
supermarkets, office buildings, enterprises and institutions,
etc., to ensure the safety of personal and property in an all-
round way.
Product functions and features
1. communication ways:
Supports PSTN, 2G/4G, and TCP/IP network communication modes.
2. System Integration
Set video, alarm, smart home in one, one key intelligent management.
3. Connectivity
The ONVIF protocol is supported by many major brand network cameras.
4. Centralized management
IPC centralized preview, centralized video, video playback, centralized
equipment management.
5. Remote control
Supports remote control on mobile phones, PCS, ipads, and Internet Explorer.
6. Data concurrency
Two independent IP communication networks, data concurrent to both
platforms.
7. Multiple functions
Two-way intercom, motion detection, POE power supply, routing, and so on.
Assembly Architecture Diagram
Wiring diagram
wiring diagram
Wired Zone Wiring
The detector power
supply pole is
connected to
12V+, and the
negative pole is
connected to 12V-.
The signal line is
connected to Z1
and COM,
and so on.
Camera video cable interface
Connect the
camera
video cable
to the 8
channels of
the host.
host computer interface
When setting up
programming, use a
VGA cable or HDMI
cable to connect to the
host terminal, and you
can enter the host
computer configuration
page for configuration.
External antenna, wired siren,
keyboard interface
The antenna is
connected to the
ANT interface, the
positive pole of the
siren Z is
connected to BEL,
and the negative
pole is connected
to GND
The keyboard is
connected
according to the
picture
Network cable interface, USB
interface
Connect the host
network port to the
user router with a
network cable.
USB port can
connect mouse and
U disk
telephone line interface
The outside line of
the telephone is
connected to the
LINE port, and the
telephone is
connected to the
TEL port.
Configure page settings
After the main unit is powered on and connected to the computer, you
can see the picture above
Configure page settings
Main page icon function introduction
Configure page settings
• Main page icon function introduction
Configure page settings
After the host is turned on, click the screen button,
and the login page shown above will be displayed. The
account admin has no password. direct login
Configure page settings
After logging in, the above page appears, we only need to
set system settings, security settings, network settings.
Configure page settings
Including: basic settings, user settings, hard disk settings, default settings,
system operation, system maintenance
Configure page settings
In the system settings, the basic settings can set the content on the
picture, and the factory default can also be used.
Configure page settings
Configure page settings
In the hard disk setting, the new hard disk needs to be formatted before
recording
Configure page settings
Configure page settings
The system operation force can shut down, restart and upgrade the system.
Configure page settings
In the system maintenance, you can set the date and time for the host to
automatically restart.
Configure page settings
Including: remote control setting, zone setting, system setting, telephone
alarm, user phone, password, GPRS setting
ID is the unique code of the wireless device, which can be directly input or
obtained wirelessly. This machine supports 8 remote controls at the same
time.
Username is the user of this remote, can be empty
Wireless siren code pairing: Turn on the siren receiver, press and hold the
save button on the wireless alarm, and click the wireless siren code pairing on
the interface. Hearing the prompt sound means that the learning is
successful. When deleting, press the Delete 1 and Delete 2 buttons
simultaneously for 1 minute.
Defense zone number: wireless defense zone 1-32, bus defense zone 33-96,
wired defense zone 97-105
Type: Burglar, Delay, Emergency, 24 Hours, Fire, Disabled
Defense zone address: the location where the defense zone is installed, it can
be empty
Siren Tone: When the defense zone alarms, what form will the siren use to
alarm, divided into continuous tone, pulse tone and mute
Enable: To use this defense zone, tick Enable
Configure page settings
Zone alarm type: refers to the type of alarm that the detector set in the zone
can report to the host computer and the alarm center after encountering an
alarm. Once the alarm is activated in the defense zone, it will send a report
message to the center according to the previously set alarm situation. In
addition, once the alarm type of a defense zone is set, no matter what kind
of alarm triggers the alarm, it will alarm according to the alarm type set in
the defense zone.
√ indicates that the host generates an alarm when the alarm is triggered.
× means that the host does not generate an alarm when the alarm is triggered,
the wireless defense zone is valid by default, and the wired defense zone is
disabled
The siren sound can be set according to the needs. It is recommended to use
different siren sounds for different alarm situations. For example, emergency
can be set to mute
Configure page settings
Click the wireless code pairing with the mouse to enter the
code pairing interface: when the code pairing is
successful, the following interface will appear
Configure page settings
Associated defense zone: In order to prevent false alarms, associate
two ringing detectors as needed. When two detectors are triggered
within the set time range, the controller will alarm, and only one
defense zone will be triggered, and the defense zone will be
activated. early warning
Note: The Associated Equipment Department recommends the use
of door magnetic switch detectors.
Configure page settings
System settings: You can set the delay time of arming and disarming, siren
time, and tick the arming and disarming report. Others can be set by
themselves as needed.
Configure page settings
Because we use the network transmission here, the alarm center telephone
alarm and user telephone can not be set
Configure page settings
Under alarm linkage, select the defense zone and the
corresponding camera channel to be set and click save
Configure page settings
Set it as needed, tick it when the timing time is valid
Configure page settings
Remote control/defense zone query: check how many remote controls are
connected to the host and the use of defense zones
Configure page settings
System alarm: no need to set if this function is not used
Configure page settings
Electrical switch: Used to control smart home products
Configure page settings
Including: encoding setting, recording setting, PTZ setting, video blocking,
color timing setting, rotation training display setting
Configure page settings
The encoding can be set by default, and the format can also be set
according to the needs: the code stream 960H is the highest. The picture
quality is divided into best, good, good, average, and poor. Frame number
1-25 can be adjusted by itself. The higher the frame rate, the better the
picture, the highest bit is 25fps.
Configure page settings
It is necessary to tick the video after the timing is valid. PTZ settings, video
occlusion, color timing settings, and rotation training settings are currently
not used and no settings are required.
Configure page settings
Including: basic settings, advanced settings, network time synchronization,
IP filtering, platform settings
Configure page settings
Tick the following IP address, fill in the IP address according to the customer
route, subnet mask: 255.255.255.0
Gateways route addresses for clients. First, enter the WAN port of the
customer router with the standby DNS. The mac address and port settings
do not need to be set.
Configure page settings
Platform settings: main alarm platform address: 119.147.144.84
Main alarm platform port: 7974
ID: It is the 8-digit number of the mainframe, and the number segment can be
freely edited according to the company's issued one, but other people's
number segments cannot be used.
Password: 12345678 is the password of the host and also the login password
of the customer's mobile phone client. It is best to unify it as 12345678.
Security service equipment integrated CCTV and burglar fire alarm

More Related Content

Similar to Security service equipment integrated CCTV and burglar fire alarm

7106506104 tl wa701-nd(eu)_2.0_qig
7106506104 tl wa701-nd(eu)_2.0_qig7106506104 tl wa701-nd(eu)_2.0_qig
7106506104 tl wa701-nd(eu)_2.0_qig
Cesar Estela Zarate
 
AHD DVR manual-vcon
AHD DVR manual-vconAHD DVR manual-vcon
AHD DVR manual-vcon
patnaglobal
 
Cn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sd
Cn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sdCn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sd
Cn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sd
kissingerman
 
White Paper on Security Systems for residential installations - Version 2.0 -...
White Paper on Security Systems for residential installations - Version 2.0 -...White Paper on Security Systems for residential installations - Version 2.0 -...
White Paper on Security Systems for residential installations - Version 2.0 -...
Ritesh Nagpal
 
TRENDnet TV-IP672WI English User Manual
TRENDnet TV-IP672WI English User ManualTRENDnet TV-IP672WI English User Manual
TRENDnet TV-IP672WI English User Manual
SecurityCameraTalk
 
Manual Smoke Sensor 10 years autonomy - Popp
 Manual Smoke Sensor 10 years autonomy - Popp Manual Smoke Sensor 10 years autonomy - Popp
Manual Smoke Sensor 10 years autonomy - Popp
Domotica daVinci
 
Manual 10 year smoke detector Z-Wave Plus-Popp
Manual 10 year smoke detector Z-Wave Plus-PoppManual 10 year smoke detector Z-Wave Plus-Popp
Manual 10 year smoke detector Z-Wave Plus-Popp
Domotica daVinci
 
Ymt dvr operation manual
Ymt dvr operation manualYmt dvr operation manual
Ymt dvr operation manual
DishHD Asia
 
Manual Outdoor motion detector Z-Wave Plus - Philio
Manual Outdoor motion detector Z-Wave Plus - PhilioManual Outdoor motion detector Z-Wave Plus - Philio
Manual Outdoor motion detector Z-Wave Plus - Philio
Domotica daVinci
 
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - PhilioManual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Domotica daVinci
 
Home automation voice control
Home automation voice controlHome automation voice control
Home automation voice control
Ahammednayeem
 
Operating instructions in english
Operating instructions in englishOperating instructions in english
Operating instructions in english
gilop2
 
Manual Motion Sensor - Z-Wave Plus - Hank
Manual Motion Sensor - Z-Wave Plus - HankManual Motion Sensor - Z-Wave Plus - Hank
Manual Motion Sensor - Z-Wave Plus - Hank
Domotica daVinci
 
Bluetooth quick start_guide / Controlanything India
Bluetooth quick start_guide / Controlanything IndiaBluetooth quick start_guide / Controlanything India
Bluetooth quick start_guide / Controlanything India
Dcube Tech Ventures
 
Zoom user manual
Zoom user manualZoom user manual
Zoom user manual
Safiah Sulaiman
 
SIG SENS W
SIG SENS WSIG SENS W
SIG SENS W
Domotica daVinci
 
Kith Infotech
Kith InfotechKith Infotech
Kith Infotech
Dignesh Bhatt
 
meZO - The missing manual
meZO - The missing manualmeZO - The missing manual
meZO - The missing manual
John Chavez
 
Digital Watchdog DWC-MV421DB User Manual
Digital Watchdog DWC-MV421DB User ManualDigital Watchdog DWC-MV421DB User Manual
Digital Watchdog DWC-MV421DB User Manual
JMAC Supply
 
Digital Watchdog DWC-MV421TIRB User Manual
Digital Watchdog DWC-MV421TIRB User ManualDigital Watchdog DWC-MV421TIRB User Manual
Digital Watchdog DWC-MV421TIRB User Manual
JMAC Supply
 

Similar to Security service equipment integrated CCTV and burglar fire alarm (20)

7106506104 tl wa701-nd(eu)_2.0_qig
7106506104 tl wa701-nd(eu)_2.0_qig7106506104 tl wa701-nd(eu)_2.0_qig
7106506104 tl wa701-nd(eu)_2.0_qig
 
AHD DVR manual-vcon
AHD DVR manual-vconAHD DVR manual-vcon
AHD DVR manual-vcon
 
Cn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sd
Cn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sdCn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sd
Cn wip604 mw h.264-ipcam-hd-wifi+pt+ir-cut+sd
 
White Paper on Security Systems for residential installations - Version 2.0 -...
White Paper on Security Systems for residential installations - Version 2.0 -...White Paper on Security Systems for residential installations - Version 2.0 -...
White Paper on Security Systems for residential installations - Version 2.0 -...
 
TRENDnet TV-IP672WI English User Manual
TRENDnet TV-IP672WI English User ManualTRENDnet TV-IP672WI English User Manual
TRENDnet TV-IP672WI English User Manual
 
Manual Smoke Sensor 10 years autonomy - Popp
 Manual Smoke Sensor 10 years autonomy - Popp Manual Smoke Sensor 10 years autonomy - Popp
Manual Smoke Sensor 10 years autonomy - Popp
 
Manual 10 year smoke detector Z-Wave Plus-Popp
Manual 10 year smoke detector Z-Wave Plus-PoppManual 10 year smoke detector Z-Wave Plus-Popp
Manual 10 year smoke detector Z-Wave Plus-Popp
 
Ymt dvr operation manual
Ymt dvr operation manualYmt dvr operation manual
Ymt dvr operation manual
 
Manual Outdoor motion detector Z-Wave Plus - Philio
Manual Outdoor motion detector Z-Wave Plus - PhilioManual Outdoor motion detector Z-Wave Plus - Philio
Manual Outdoor motion detector Z-Wave Plus - Philio
 
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - PhilioManual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
 
Home automation voice control
Home automation voice controlHome automation voice control
Home automation voice control
 
Operating instructions in english
Operating instructions in englishOperating instructions in english
Operating instructions in english
 
Manual Motion Sensor - Z-Wave Plus - Hank
Manual Motion Sensor - Z-Wave Plus - HankManual Motion Sensor - Z-Wave Plus - Hank
Manual Motion Sensor - Z-Wave Plus - Hank
 
Bluetooth quick start_guide / Controlanything India
Bluetooth quick start_guide / Controlanything IndiaBluetooth quick start_guide / Controlanything India
Bluetooth quick start_guide / Controlanything India
 
Zoom user manual
Zoom user manualZoom user manual
Zoom user manual
 
SIG SENS W
SIG SENS WSIG SENS W
SIG SENS W
 
Kith Infotech
Kith InfotechKith Infotech
Kith Infotech
 
meZO - The missing manual
meZO - The missing manualmeZO - The missing manual
meZO - The missing manual
 
Digital Watchdog DWC-MV421DB User Manual
Digital Watchdog DWC-MV421DB User ManualDigital Watchdog DWC-MV421DB User Manual
Digital Watchdog DWC-MV421DB User Manual
 
Digital Watchdog DWC-MV421TIRB User Manual
Digital Watchdog DWC-MV421TIRB User ManualDigital Watchdog DWC-MV421TIRB User Manual
Digital Watchdog DWC-MV421TIRB User Manual
 

More from Vedard Security Alarm System Store

wireless fire alarm installation and debugging procedures.pdf
wireless fire  alarm installation and debugging procedures.pdfwireless fire  alarm installation and debugging procedures.pdf
wireless fire alarm installation and debugging procedures.pdf
Vedard Security Alarm System Store
 
linkage of gas fire extinguishing system with fire alarm
linkage of gas fire extinguishing system with fire alarmlinkage of gas fire extinguishing system with fire alarm
linkage of gas fire extinguishing system with fire alarm
Vedard Security Alarm System Store
 
Fire alarm and gas extinguishing system instruction
Fire alarm and gas extinguishing system instructionFire alarm and gas extinguishing system instruction
Fire alarm and gas extinguishing system instruction
Vedard Security Alarm System Store
 
test of gas fire extinguishing system
test of gas fire extinguishing systemtest of gas fire extinguishing system
test of gas fire extinguishing system
Vedard Security Alarm System Store
 
electric fire temperature detectors
electric fire temperature detectorselectric fire temperature detectors
electric fire temperature detectors
Vedard Security Alarm System Store
 
independent electric fire detection system
independent electric fire detection systemindependent electric fire detection system
independent electric fire detection system
Vedard Security Alarm System Store
 
fire alarm linkage smoke exhaust
fire alarm linkage smoke exhaustfire alarm linkage smoke exhaust
fire alarm linkage smoke exhaust
Vedard Security Alarm System Store
 
linkage fire alarm system parts
linkage fire alarm system partslinkage fire alarm system parts
linkage fire alarm system parts
Vedard Security Alarm System Store
 
addressable fire alarm system loop
addressable fire alarm system loopaddressable fire alarm system loop
addressable fire alarm system loop
Vedard Security Alarm System Store
 
addressable fire alarm system bus loop
addressable fire alarm system bus loopaddressable fire alarm system bus loop
addressable fire alarm system bus loop
Vedard Security Alarm System Store
 
fire alarm system types
fire alarm system typesfire alarm system types
fire alarm system types
Vedard Security Alarm System Store
 
fire alarm system fire graphic display device
fire alarm system fire graphic display devicefire alarm system fire graphic display device
fire alarm system fire graphic display device
Vedard Security Alarm System Store
 
overview of automatic fire-alarm systems
overview of automatic fire-alarm systemsoverview of automatic fire-alarm systems
overview of automatic fire-alarm systems
Vedard Security Alarm System Store
 
division of fire alarm areas
division of fire alarm areasdivision of fire alarm areas
division of fire alarm areas
Vedard Security Alarm System Store
 
addressable fire alarm bus short circuit isolator
addressable fire alarm bus short circuit isolatoraddressable fire alarm bus short circuit isolator
addressable fire alarm bus short circuit isolator
Vedard Security Alarm System Store
 
fire manual call and hydrant button
fire manual call and hydrant buttonfire manual call and hydrant button
fire manual call and hydrant button
Vedard Security Alarm System Store
 
addressable fire alarm system input module
addressable fire alarm system input moduleaddressable fire alarm system input module
addressable fire alarm system input module
Vedard Security Alarm System Store
 
carbon monoxide detection system
carbon monoxide detection systemcarbon monoxide detection system
carbon monoxide detection system
Vedard Security Alarm System Store
 
gas fire extinguish system
gas fire extinguish systemgas fire extinguish system
gas fire extinguish system
Vedard Security Alarm System Store
 
Residual current electrical fire detector
Residual current electrical fire detectorResidual current electrical fire detector
Residual current electrical fire detector
Vedard Security Alarm System Store
 

More from Vedard Security Alarm System Store (20)

wireless fire alarm installation and debugging procedures.pdf
wireless fire  alarm installation and debugging procedures.pdfwireless fire  alarm installation and debugging procedures.pdf
wireless fire alarm installation and debugging procedures.pdf
 
linkage of gas fire extinguishing system with fire alarm
linkage of gas fire extinguishing system with fire alarmlinkage of gas fire extinguishing system with fire alarm
linkage of gas fire extinguishing system with fire alarm
 
Fire alarm and gas extinguishing system instruction
Fire alarm and gas extinguishing system instructionFire alarm and gas extinguishing system instruction
Fire alarm and gas extinguishing system instruction
 
test of gas fire extinguishing system
test of gas fire extinguishing systemtest of gas fire extinguishing system
test of gas fire extinguishing system
 
electric fire temperature detectors
electric fire temperature detectorselectric fire temperature detectors
electric fire temperature detectors
 
independent electric fire detection system
independent electric fire detection systemindependent electric fire detection system
independent electric fire detection system
 
fire alarm linkage smoke exhaust
fire alarm linkage smoke exhaustfire alarm linkage smoke exhaust
fire alarm linkage smoke exhaust
 
linkage fire alarm system parts
linkage fire alarm system partslinkage fire alarm system parts
linkage fire alarm system parts
 
addressable fire alarm system loop
addressable fire alarm system loopaddressable fire alarm system loop
addressable fire alarm system loop
 
addressable fire alarm system bus loop
addressable fire alarm system bus loopaddressable fire alarm system bus loop
addressable fire alarm system bus loop
 
fire alarm system types
fire alarm system typesfire alarm system types
fire alarm system types
 
fire alarm system fire graphic display device
fire alarm system fire graphic display devicefire alarm system fire graphic display device
fire alarm system fire graphic display device
 
overview of automatic fire-alarm systems
overview of automatic fire-alarm systemsoverview of automatic fire-alarm systems
overview of automatic fire-alarm systems
 
division of fire alarm areas
division of fire alarm areasdivision of fire alarm areas
division of fire alarm areas
 
addressable fire alarm bus short circuit isolator
addressable fire alarm bus short circuit isolatoraddressable fire alarm bus short circuit isolator
addressable fire alarm bus short circuit isolator
 
fire manual call and hydrant button
fire manual call and hydrant buttonfire manual call and hydrant button
fire manual call and hydrant button
 
addressable fire alarm system input module
addressable fire alarm system input moduleaddressable fire alarm system input module
addressable fire alarm system input module
 
carbon monoxide detection system
carbon monoxide detection systemcarbon monoxide detection system
carbon monoxide detection system
 
gas fire extinguish system
gas fire extinguish systemgas fire extinguish system
gas fire extinguish system
 
Residual current electrical fire detector
Residual current electrical fire detectorResidual current electrical fire detector
Residual current electrical fire detector
 

Recently uploaded

Manufacturing Process of molasses based distillery ppt.pptx
Manufacturing Process of molasses based distillery ppt.pptxManufacturing Process of molasses based distillery ppt.pptx
Manufacturing Process of molasses based distillery ppt.pptx
Madan Karki
 
Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...
Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...
Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...
shadow0702a
 
Generative AI leverages algorithms to create various forms of content
Generative AI leverages algorithms to create various forms of contentGenerative AI leverages algorithms to create various forms of content
Generative AI leverages algorithms to create various forms of content
Hitesh Mohapatra
 
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024
Sinan KOZAK
 
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
IJECEIAES
 
artificial intelligence and data science contents.pptx
artificial intelligence and data science contents.pptxartificial intelligence and data science contents.pptx
artificial intelligence and data science contents.pptx
GauravCar
 
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
IJECEIAES
 
spirit beverages ppt without graphics.pptx
spirit beverages ppt without graphics.pptxspirit beverages ppt without graphics.pptx
spirit beverages ppt without graphics.pptx
Madan Karki
 
Seminar on Distillation study-mafia.pptx
Seminar on Distillation study-mafia.pptxSeminar on Distillation study-mafia.pptx
Seminar on Distillation study-mafia.pptx
Madan Karki
 
Applications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdfApplications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdf
Atif Razi
 
AI assisted telemedicine KIOSK for Rural India.pptx
AI assisted telemedicine KIOSK for Rural India.pptxAI assisted telemedicine KIOSK for Rural India.pptx
AI assisted telemedicine KIOSK for Rural India.pptx
architagupta876
 
Software Quality Assurance-se412-v11.ppt
Software Quality Assurance-se412-v11.pptSoftware Quality Assurance-se412-v11.ppt
Software Quality Assurance-se412-v11.ppt
TaghreedAltamimi
 
4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf
4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf
4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf
Gino153088
 
Rainfall intensity duration frequency curve statistical analysis and modeling...
Rainfall intensity duration frequency curve statistical analysis and modeling...Rainfall intensity duration frequency curve statistical analysis and modeling...
Rainfall intensity duration frequency curve statistical analysis and modeling...
bijceesjournal
 
cnn.pptx Convolutional neural network used for image classication
cnn.pptx Convolutional neural network used for image classicationcnn.pptx Convolutional neural network used for image classication
cnn.pptx Convolutional neural network used for image classication
SakkaravarthiShanmug
 
132/33KV substation case study Presentation
132/33KV substation case study Presentation132/33KV substation case study Presentation
132/33KV substation case study Presentation
kandramariana6
 
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
insn4465
 
Certificates - Mahmoud Mohamed Moursi Ahmed
Certificates - Mahmoud Mohamed Moursi AhmedCertificates - Mahmoud Mohamed Moursi Ahmed
Certificates - Mahmoud Mohamed Moursi Ahmed
Mahmoud Morsy
 
Unit-III-ELECTROCHEMICAL STORAGE DEVICES.ppt
Unit-III-ELECTROCHEMICAL STORAGE DEVICES.pptUnit-III-ELECTROCHEMICAL STORAGE DEVICES.ppt
Unit-III-ELECTROCHEMICAL STORAGE DEVICES.ppt
KrishnaveniKrishnara1
 
Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...
Prakhyath Rai
 

Recently uploaded (20)

Manufacturing Process of molasses based distillery ppt.pptx
Manufacturing Process of molasses based distillery ppt.pptxManufacturing Process of molasses based distillery ppt.pptx
Manufacturing Process of molasses based distillery ppt.pptx
 
Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...
Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...
Use PyCharm for remote debugging of WSL on a Windo cf5c162d672e4e58b4dde5d797...
 
Generative AI leverages algorithms to create various forms of content
Generative AI leverages algorithms to create various forms of contentGenerative AI leverages algorithms to create various forms of content
Generative AI leverages algorithms to create various forms of content
 
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024
Optimizing Gradle Builds - Gradle DPE Tour Berlin 2024
 
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
 
artificial intelligence and data science contents.pptx
artificial intelligence and data science contents.pptxartificial intelligence and data science contents.pptx
artificial intelligence and data science contents.pptx
 
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
 
spirit beverages ppt without graphics.pptx
spirit beverages ppt without graphics.pptxspirit beverages ppt without graphics.pptx
spirit beverages ppt without graphics.pptx
 
Seminar on Distillation study-mafia.pptx
Seminar on Distillation study-mafia.pptxSeminar on Distillation study-mafia.pptx
Seminar on Distillation study-mafia.pptx
 
Applications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdfApplications of artificial Intelligence in Mechanical Engineering.pdf
Applications of artificial Intelligence in Mechanical Engineering.pdf
 
AI assisted telemedicine KIOSK for Rural India.pptx
AI assisted telemedicine KIOSK for Rural India.pptxAI assisted telemedicine KIOSK for Rural India.pptx
AI assisted telemedicine KIOSK for Rural India.pptx
 
Software Quality Assurance-se412-v11.ppt
Software Quality Assurance-se412-v11.pptSoftware Quality Assurance-se412-v11.ppt
Software Quality Assurance-se412-v11.ppt
 
4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf
4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf
4. Mosca vol I -Fisica-Tipler-5ta-Edicion-Vol-1.pdf
 
Rainfall intensity duration frequency curve statistical analysis and modeling...
Rainfall intensity duration frequency curve statistical analysis and modeling...Rainfall intensity duration frequency curve statistical analysis and modeling...
Rainfall intensity duration frequency curve statistical analysis and modeling...
 
cnn.pptx Convolutional neural network used for image classication
cnn.pptx Convolutional neural network used for image classicationcnn.pptx Convolutional neural network used for image classication
cnn.pptx Convolutional neural network used for image classication
 
132/33KV substation case study Presentation
132/33KV substation case study Presentation132/33KV substation case study Presentation
132/33KV substation case study Presentation
 
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
 
Certificates - Mahmoud Mohamed Moursi Ahmed
Certificates - Mahmoud Mohamed Moursi AhmedCertificates - Mahmoud Mohamed Moursi Ahmed
Certificates - Mahmoud Mohamed Moursi Ahmed
 
Unit-III-ELECTROCHEMICAL STORAGE DEVICES.ppt
Unit-III-ELECTROCHEMICAL STORAGE DEVICES.pptUnit-III-ELECTROCHEMICAL STORAGE DEVICES.ppt
Unit-III-ELECTROCHEMICAL STORAGE DEVICES.ppt
 
Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...Software Engineering and Project Management - Introduction, Modeling Concepts...
Software Engineering and Project Management - Introduction, Modeling Concepts...
 

Security service equipment integrated CCTV and burglar fire alarm

  • 2. foreword EAVS-2506 is an alarm video integrated host using H.265 video compression. The host supports 6-way POE high- definition network video access, and supports multiple wired and wireless and bus defense zones. Built-in 2G/4G network module and TCP/IP network module, dual network communication, stable and reliable performance. It has special functions such as high-definition monitoring, intelligent anti-theft, two-way intercom, intelligent home appliances, remote control, and centralized management. It is widely used in residential areas, villas, shops, chain supermarkets, office buildings, enterprises and institutions, etc., to ensure the safety of personal and property in an all- round way.
  • 3. Product functions and features 1. communication ways: Supports PSTN, 2G/4G, and TCP/IP network communication modes. 2. System Integration Set video, alarm, smart home in one, one key intelligent management. 3. Connectivity The ONVIF protocol is supported by many major brand network cameras. 4. Centralized management IPC centralized preview, centralized video, video playback, centralized equipment management. 5. Remote control Supports remote control on mobile phones, PCS, ipads, and Internet Explorer. 6. Data concurrency Two independent IP communication networks, data concurrent to both platforms. 7. Multiple functions Two-way intercom, motion detection, POE power supply, routing, and so on.
  • 7. Wired Zone Wiring The detector power supply pole is connected to 12V+, and the negative pole is connected to 12V-. The signal line is connected to Z1 and COM, and so on.
  • 8. Camera video cable interface Connect the camera video cable to the 8 channels of the host.
  • 9. host computer interface When setting up programming, use a VGA cable or HDMI cable to connect to the host terminal, and you can enter the host computer configuration page for configuration.
  • 10. External antenna, wired siren, keyboard interface The antenna is connected to the ANT interface, the positive pole of the siren Z is connected to BEL, and the negative pole is connected to GND The keyboard is connected according to the picture
  • 11. Network cable interface, USB interface Connect the host network port to the user router with a network cable. USB port can connect mouse and U disk
  • 12. telephone line interface The outside line of the telephone is connected to the LINE port, and the telephone is connected to the TEL port.
  • 13. Configure page settings After the main unit is powered on and connected to the computer, you can see the picture above
  • 14. Configure page settings Main page icon function introduction
  • 15. Configure page settings • Main page icon function introduction
  • 16. Configure page settings After the host is turned on, click the screen button, and the login page shown above will be displayed. The account admin has no password. direct login
  • 17. Configure page settings After logging in, the above page appears, we only need to set system settings, security settings, network settings.
  • 18. Configure page settings Including: basic settings, user settings, hard disk settings, default settings, system operation, system maintenance
  • 19. Configure page settings In the system settings, the basic settings can set the content on the picture, and the factory default can also be used.
  • 21. Configure page settings In the hard disk setting, the new hard disk needs to be formatted before recording
  • 23. Configure page settings The system operation force can shut down, restart and upgrade the system.
  • 24. Configure page settings In the system maintenance, you can set the date and time for the host to automatically restart.
  • 25. Configure page settings Including: remote control setting, zone setting, system setting, telephone alarm, user phone, password, GPRS setting
  • 26. ID is the unique code of the wireless device, which can be directly input or obtained wirelessly. This machine supports 8 remote controls at the same time. Username is the user of this remote, can be empty Wireless siren code pairing: Turn on the siren receiver, press and hold the save button on the wireless alarm, and click the wireless siren code pairing on the interface. Hearing the prompt sound means that the learning is successful. When deleting, press the Delete 1 and Delete 2 buttons simultaneously for 1 minute.
  • 27. Defense zone number: wireless defense zone 1-32, bus defense zone 33-96, wired defense zone 97-105 Type: Burglar, Delay, Emergency, 24 Hours, Fire, Disabled Defense zone address: the location where the defense zone is installed, it can be empty Siren Tone: When the defense zone alarms, what form will the siren use to alarm, divided into continuous tone, pulse tone and mute Enable: To use this defense zone, tick Enable
  • 28. Configure page settings Zone alarm type: refers to the type of alarm that the detector set in the zone can report to the host computer and the alarm center after encountering an alarm. Once the alarm is activated in the defense zone, it will send a report message to the center according to the previously set alarm situation. In addition, once the alarm type of a defense zone is set, no matter what kind of alarm triggers the alarm, it will alarm according to the alarm type set in the defense zone. √ indicates that the host generates an alarm when the alarm is triggered. × means that the host does not generate an alarm when the alarm is triggered, the wireless defense zone is valid by default, and the wired defense zone is disabled The siren sound can be set according to the needs. It is recommended to use different siren sounds for different alarm situations. For example, emergency can be set to mute
  • 29. Configure page settings Click the wireless code pairing with the mouse to enter the code pairing interface: when the code pairing is successful, the following interface will appear
  • 30. Configure page settings Associated defense zone: In order to prevent false alarms, associate two ringing detectors as needed. When two detectors are triggered within the set time range, the controller will alarm, and only one defense zone will be triggered, and the defense zone will be activated. early warning Note: The Associated Equipment Department recommends the use of door magnetic switch detectors.
  • 31. Configure page settings System settings: You can set the delay time of arming and disarming, siren time, and tick the arming and disarming report. Others can be set by themselves as needed.
  • 32. Configure page settings Because we use the network transmission here, the alarm center telephone alarm and user telephone can not be set
  • 33. Configure page settings Under alarm linkage, select the defense zone and the corresponding camera channel to be set and click save
  • 34. Configure page settings Set it as needed, tick it when the timing time is valid
  • 35. Configure page settings Remote control/defense zone query: check how many remote controls are connected to the host and the use of defense zones
  • 36. Configure page settings System alarm: no need to set if this function is not used
  • 37. Configure page settings Electrical switch: Used to control smart home products
  • 38. Configure page settings Including: encoding setting, recording setting, PTZ setting, video blocking, color timing setting, rotation training display setting
  • 39. Configure page settings The encoding can be set by default, and the format can also be set according to the needs: the code stream 960H is the highest. The picture quality is divided into best, good, good, average, and poor. Frame number 1-25 can be adjusted by itself. The higher the frame rate, the better the picture, the highest bit is 25fps.
  • 40. Configure page settings It is necessary to tick the video after the timing is valid. PTZ settings, video occlusion, color timing settings, and rotation training settings are currently not used and no settings are required.
  • 41. Configure page settings Including: basic settings, advanced settings, network time synchronization, IP filtering, platform settings
  • 42. Configure page settings Tick the following IP address, fill in the IP address according to the customer route, subnet mask: 255.255.255.0 Gateways route addresses for clients. First, enter the WAN port of the customer router with the standby DNS. The mac address and port settings do not need to be set.
  • 43. Configure page settings Platform settings: main alarm platform address: 119.147.144.84 Main alarm platform port: 7974 ID: It is the 8-digit number of the mainframe, and the number segment can be freely edited according to the company's issued one, but other people's number segments cannot be used. Password: 12345678 is the password of the host and also the login password of the customer's mobile phone client. It is best to unify it as 12345678.