Background
 Every day various quantities of particulates, vapors, gases
and radionuclides are discharged to the environment from
various power generation plants and production facilities.
 In general, the airborne effluent from nuclear power plants is
discharged continuously through one or more vents or stacks
of various heights.
2
Background (cont’d)
 The released airborne radioactive pollutants can be summarized into the
following categories:
 Gaseous
 Vapor
 Particulate
 The radionuclides are produced by a result of two processes:
 The first process is the formation of fission products, which are produced
when uranium atoms in the fuel are split.
 The second process is activation, which occurs when atoms of other
material within the system are made radioactive by neutron bombardment.
3
Key Terms
• A term used as a single dimension to describe a particle size in a
fluid medium.
Aerodynamic Equivalent
Diameter (AED)
• The particle size distribution curve relating to one size particleMonodisperse
• Dimension less number that relates variables describing flow,
velocity, density and viscosity.Reynolds Number
• The percent of particulate that is transported from the nozzle to
the collection media.Transport Efficiency
• The region of Reynolds numbers between laminar (<2500) and
turbulent flow (>4000) which relates variables describing flow,
velocity, density and viscosity.
Transition Region
4
System Description
 The system draws a continuous air sample from
the sampling probe located high in the effluent
stack.
 The air sample is drawn through the sample lines
to a series of filters consisting of a particulate filter,
an iodine filter, a noble gas chamber and a pump
then discharged to the stack.
5
Sampling Systems FAQ’s
 Is there one “Universal” monitoring system configuration?
 No. Various monitoring system configurations are used by the nuclear power plant
operators or utilities to comply with NUREG 0737 and Reg Guide 1.97.
 Why do the sampling systems have problems?
 These sampling systems can have inherent problems associated with representative
sampling because of the complexity and length of the sampling line.
 How effective are the sampling systems?
 One utility initiated a program to measure the effectiveness of the sampling systems
and found several mechanical problems (fans, baffles, probes, etc.) that affected their
effluent monitoring program.
 What did reviews of the stacks show?
 Reviews performed for stacks found that the stack flows and the flow profiles were
significantly different than the design flows used in their emission calculations.
6
Sampling System FAQ’s (cont’d)
 What is the purpose of a sample system model?
 A sample system model provides an insight of which factors can influence the sample
transport efficiency of a sampling system.
 The sample flow velocity (v) is an important factor in the transport efficiency of
particles through a sampling system.
 What are the various design parameters, and what do they do?
 The sample flow rate, tubing diameter and Reynolds Number are design parameters
that directly determine the flow velocity through the sample system
7
Particle Transmission Efficiency –
Fx of Sample Flow & Reynolds Number 8
Sampling System Maintenance
 Perform a maintenance check on the sampling system actual pump flow variance
 Check each probe and sample line for cleanliness.
 Check system installation for the number of bends and bend curvature radius.
 Higher transport efficiencies can be achieved when sampling line
installations minimize flow direction changes.
 Check Moisture content residual in sampling lines
 Pressure test for Air-Leakage within Sample lines
 A periodic check of the flow profile should be performed to check the effluent
stream characteristics for sampling location.
9
Sampling Point Challenges
 The sampling point available for use may not provide a valid
representation sample of the effluent.
 A flow profile should be generated for each sample point location. This
ensures that under varying plant conditions, the sample point is
representative of the system stream.
10
RMS: A Dynamic System
 Flow rate and tubing diameter will affect transport efficiency based on
particle sizing, plate out and impaction.
 The transport efficiency of particles through a sample line may vary by
50% or more due to sample flow rate, and tubing diameter.
 The RMS accuracy increases by reducing the sampling error and the
extent of the scaling factors used to determine the particulate effluent
release.
 The effluent particulate monitoring repeatability increases due to the
transport efficiency being optimized.
11
Transport Efficiency
 The transport efficiency is a function of particle size: as the particle size
increases, the transport efficiency decreases. The median particle aerodynamic
size should be determined for the distribution range of the mixture.
 The limitation of the sample transport efficiency of the radiation monitoring
sampling system is that it is based on a particular particle size and not the
mixture.
12
Optimization of Design Parameters
 The transmission of a 5μm AED particle with a density of 1.5 g/cm3 drawn
through the sample system model at 56.630 l/min yields only a 26%
transmission efficiency.
 The transmission efficiency of a particle is a function of the sample tube
diameter. The optimum internal diameter for this sample system model with
the design flow of 56.630 l/min is 22.926 mm.
 The sample line transmission efficiency for this sample system model can
be increased to 27% for a 5μm AED particle with a density of 1.5 g/cm3 by
increasing the flow to approximately 70 l/min. The transmission efficiency of
all particles less than 10μm AED is increased by raising the sample flow
rate to 70 l/min.
13
Particle Transport Efficiency 14
Optimization of Design Parameters
 The transmission efficiency of particles is a function that is inversely
proportionate to the particle density. As the particle density
increases, the transmission efficiency decreases.
 At the optimum sample flow rate of 70 l/min, the transmission
efficiency for AED particle with a density range of 1.00 to 2.00
g/cm3 varies by only 0.1%.
 The sampling system Reynolds number is in the transition region to
achieve optimum transport efficiency.
15
Recommendations: Sampling System
 Perform an analysis of the sample stream to
determine the range of particle sizes and density.
 Develop a model for the sampling system to
determine the transmission efficiency for the
system based on particle size and density. It is
not a monodisperse particle.
• Determine the optimum sample flow rate for the sampling system.
Do not rely on what the vendor or manufacturer has stated the
sample flow rate should be for their radiation monitoring system skid.
16
Filter Efficiency vs Particle Size
• Review the filter collection media specifications to
ensure the filter is sized appropriately for the flow
velocity.
17
Conclusions
 The RMS Sampling System is key to proper system operation
and dose measurement
 RMS Sampling systems need periodic maintenance
 It’s important to understand what the design parameters are for
the sampling system
 Performing detailed reviews will ensure system is not
operationally challenged
18
References
 Menge J, (1997); “Optimization of Airborne Effluent Sampling Systems for Nuclear
Power Plants”
 Schmidt, A (1988); “ A Three-Part Strategy for Continuous Extractive Monitoring for
Hazardous Particulate Emissions from Exhaust Stacks”
 Schwendiman, Stegen, Glissmeyer (1975); “Methods and Aids for Assessing Particle
Losses in Sampling Lines”
 ANSI N13.1-1995; American National Standard Institute “Guide to Monitoring Releases
of Airborne Radioactive Substances from Ducts and Stacks of Nuclear Facilities”.
 NUREG 0737 (1983); “Clarification of TMI Action Plan Requirements”
 US NRC Regulatory Guide 1.97 Rev 3 (1983); “Instrumentation for Light-Cooled
Nuclear Power Plants to Assess Plant and Environs Conditions During and Following
an Accident”
19
RMS- Optimization of Sampling Systems
Thank You
SME Associates LLC
Providing Innovating Solutions
20

More Related Content

What's hot

SURE Research Report v1
SURE Research Report v1SURE Research Report v1
SURE Research Report v1Dana Joaquin
 
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling StudyPIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling StudyMarcellus Drilling News
 
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...Mudasir Gulzar
 
Application of hyphenated techniques(GC-MS)
Application of hyphenated techniques(GC-MS)Application of hyphenated techniques(GC-MS)
Application of hyphenated techniques(GC-MS)Dr. Dinesh Mehta
 
Post CMP Clean Effluent End pointing and Monitoring with the LNS System
Post CMP Clean Effluent End pointing and Monitoring with the LNS SystemPost CMP Clean Effluent End pointing and Monitoring with the LNS System
Post CMP Clean Effluent End pointing and Monitoring with the LNS Systemkanomaxfmt
 
AIR SAMPLING ANALYSIS AND METHODOLOGY
AIR SAMPLING ANALYSIS AND METHODOLOGYAIR SAMPLING ANALYSIS AND METHODOLOGY
AIR SAMPLING ANALYSIS AND METHODOLOGYSiti Mastura
 
Gc ms(mr.s)
Gc ms(mr.s)Gc ms(mr.s)
Gc ms(mr.s)22suresh
 
IEEE Sensor journal 2016 Title and Abstract
IEEE Sensor journal 2016 Title and AbstractIEEE Sensor journal 2016 Title and Abstract
IEEE Sensor journal 2016 Title and Abstracttsysglobalsolutions
 
Review of hyphenated techechnique.
Review of hyphenated techechnique.Review of hyphenated techechnique.
Review of hyphenated techechnique.Sundaybb1992
 
MRK2231-01_OD_broch_Viscosizer_TD_v2
MRK2231-01_OD_broch_Viscosizer_TD_v2MRK2231-01_OD_broch_Viscosizer_TD_v2
MRK2231-01_OD_broch_Viscosizer_TD_v2Rajib Ahmed
 
Calibration of IR spectrophotometer ppt
Calibration of IR spectrophotometer pptCalibration of IR spectrophotometer ppt
Calibration of IR spectrophotometer pptSIHAS
 
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
Hyphenated techniques(GC-MS/MS, LC-MS/MS,  HPTLC-MS)Hyphenated techniques(GC-MS/MS, LC-MS/MS,  HPTLC-MS)
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)Dr. Dinesh Mehta
 
Hyphenated techniques- GCMS, LCMS, GCIR
Hyphenated techniques- GCMS, LCMS, GCIRHyphenated techniques- GCMS, LCMS, GCIR
Hyphenated techniques- GCMS, LCMS, GCIRSanket Shinde
 
A review on application of hyphenated
A review on application of hyphenatedA review on application of hyphenated
A review on application of hyphenatedYahsé Challa
 
Application of hyphenated techniques
Application of hyphenated techniques Application of hyphenated techniques
Application of hyphenated techniques Dr. Dinesh Mehta
 

What's hot (20)

Triple Quadrupole Gas Chromatography-Mass Spectrometry/Mass Spectrometry Re-i...
Triple Quadrupole Gas Chromatography-Mass Spectrometry/Mass Spectrometry Re-i...Triple Quadrupole Gas Chromatography-Mass Spectrometry/Mass Spectrometry Re-i...
Triple Quadrupole Gas Chromatography-Mass Spectrometry/Mass Spectrometry Re-i...
 
SURE Research Report v1
SURE Research Report v1SURE Research Report v1
SURE Research Report v1
 
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling StudyPIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
 
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
 
GCMS
GCMSGCMS
GCMS
 
Application of hyphenated techniques(GC-MS)
Application of hyphenated techniques(GC-MS)Application of hyphenated techniques(GC-MS)
Application of hyphenated techniques(GC-MS)
 
Post CMP Clean Effluent End pointing and Monitoring with the LNS System
Post CMP Clean Effluent End pointing and Monitoring with the LNS SystemPost CMP Clean Effluent End pointing and Monitoring with the LNS System
Post CMP Clean Effluent End pointing and Monitoring with the LNS System
 
Air sampling
Air samplingAir sampling
Air sampling
 
AIR SAMPLING ANALYSIS AND METHODOLOGY
AIR SAMPLING ANALYSIS AND METHODOLOGYAIR SAMPLING ANALYSIS AND METHODOLOGY
AIR SAMPLING ANALYSIS AND METHODOLOGY
 
Gc ms(mr.s)
Gc ms(mr.s)Gc ms(mr.s)
Gc ms(mr.s)
 
IEEE Sensor journal 2016 Title and Abstract
IEEE Sensor journal 2016 Title and AbstractIEEE Sensor journal 2016 Title and Abstract
IEEE Sensor journal 2016 Title and Abstract
 
Review of hyphenated techechnique.
Review of hyphenated techechnique.Review of hyphenated techechnique.
Review of hyphenated techechnique.
 
MRK2231-01_OD_broch_Viscosizer_TD_v2
MRK2231-01_OD_broch_Viscosizer_TD_v2MRK2231-01_OD_broch_Viscosizer_TD_v2
MRK2231-01_OD_broch_Viscosizer_TD_v2
 
Calibration of IR spectrophotometer ppt
Calibration of IR spectrophotometer pptCalibration of IR spectrophotometer ppt
Calibration of IR spectrophotometer ppt
 
GC-MS
GC-MSGC-MS
GC-MS
 
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
Hyphenated techniques(GC-MS/MS, LC-MS/MS,  HPTLC-MS)Hyphenated techniques(GC-MS/MS, LC-MS/MS,  HPTLC-MS)
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
 
Hyphenated techniques- GCMS, LCMS, GCIR
Hyphenated techniques- GCMS, LCMS, GCIRHyphenated techniques- GCMS, LCMS, GCIR
Hyphenated techniques- GCMS, LCMS, GCIR
 
GC-MS
GC-MSGC-MS
GC-MS
 
A review on application of hyphenated
A review on application of hyphenatedA review on application of hyphenated
A review on application of hyphenated
 
Application of hyphenated techniques
Application of hyphenated techniques Application of hyphenated techniques
Application of hyphenated techniques
 

Similar to RMS- Optimization of Sampling Systems

Determination of Suspended PM in Atmosphere
Determination of Suspended PM in AtmosphereDetermination of Suspended PM in Atmosphere
Determination of Suspended PM in AtmosphereECRD IN
 
Part technical cleanliness/Millipore
Part technical cleanliness/MilliporePart technical cleanliness/Millipore
Part technical cleanliness/MilliporeSURAJ JATHAR
 
Liquid Level Estimation in Dynamic Condition using Kalman Filter
Liquid Level Estimation in Dynamic Condition using Kalman FilterLiquid Level Estimation in Dynamic Condition using Kalman Filter
Liquid Level Estimation in Dynamic Condition using Kalman FilterIJERA Editor
 
Automated analysis 112070804013
Automated analysis 112070804013Automated analysis 112070804013
Automated analysis 112070804013Patel Parth
 
Biomedical Instrumentation auto analyser.pptx
Biomedical Instrumentation auto analyser.pptxBiomedical Instrumentation auto analyser.pptx
Biomedical Instrumentation auto analyser.pptxDrAyyarKandasamy
 
Oxygen mass transfer coefficient by various methods
Oxygen mass transfer coefficient by various methodsOxygen mass transfer coefficient by various methods
Oxygen mass transfer coefficient by various methodsVaishnavi808494
 
Introduction to analytical instrumentation.
Introduction to analytical instrumentation.Introduction to analytical instrumentation.
Introduction to analytical instrumentation.Analysys
 
Jurnalku pompa
Jurnalku pompaJurnalku pompa
Jurnalku pompaAmardhiana
 
ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...
ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...
ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...rajivsaik
 
ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...
ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...
ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...kanomaxfmt
 
How can identify sensitivity of hydraulic characteristics of irrigation systems?
How can identify sensitivity of hydraulic characteristics of irrigation systems?How can identify sensitivity of hydraulic characteristics of irrigation systems?
How can identify sensitivity of hydraulic characteristics of irrigation systems?AI Publications
 
Cfd analaysis of flow through a conical exhaust
Cfd analaysis of flow through a conical exhaustCfd analaysis of flow through a conical exhaust
Cfd analaysis of flow through a conical exhausteSAT Publishing House
 
Methods of particle size measrement (032)
Methods of particle size measrement (032)Methods of particle size measrement (032)
Methods of particle size measrement (032)Hafiz Luqman Khalil
 
Ppt HADJI.pptx
Ppt HADJI.pptxPpt HADJI.pptx
Ppt HADJI.pptxayoubemeca
 
PPT - Electronics Industry Wastewater
PPT - Electronics Industry WastewaterPPT - Electronics Industry Wastewater
PPT - Electronics Industry WastewaterNitin Yadav
 
A Novel Method for Measuring the Sizes and Concentrations
A Novel Method for Measuring the Sizes and ConcentrationsA Novel Method for Measuring the Sizes and Concentrations
A Novel Method for Measuring the Sizes and Concentrationskanomaxfmt
 
jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...
jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...
jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...Yaobo Ding
 
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...Ruturaj Deshpande
 

Similar to RMS- Optimization of Sampling Systems (20)

M epockete nf
M epockete nfM epockete nf
M epockete nf
 
OX2 230-Oxygen-Transmission-rate-Test-System
OX2 230-Oxygen-Transmission-rate-Test-SystemOX2 230-Oxygen-Transmission-rate-Test-System
OX2 230-Oxygen-Transmission-rate-Test-System
 
Determination of Suspended PM in Atmosphere
Determination of Suspended PM in AtmosphereDetermination of Suspended PM in Atmosphere
Determination of Suspended PM in Atmosphere
 
Part technical cleanliness/Millipore
Part technical cleanliness/MilliporePart technical cleanliness/Millipore
Part technical cleanliness/Millipore
 
Liquid Level Estimation in Dynamic Condition using Kalman Filter
Liquid Level Estimation in Dynamic Condition using Kalman FilterLiquid Level Estimation in Dynamic Condition using Kalman Filter
Liquid Level Estimation in Dynamic Condition using Kalman Filter
 
Automated analysis 112070804013
Automated analysis 112070804013Automated analysis 112070804013
Automated analysis 112070804013
 
Biomedical Instrumentation auto analyser.pptx
Biomedical Instrumentation auto analyser.pptxBiomedical Instrumentation auto analyser.pptx
Biomedical Instrumentation auto analyser.pptx
 
Oxygen mass transfer coefficient by various methods
Oxygen mass transfer coefficient by various methodsOxygen mass transfer coefficient by various methods
Oxygen mass transfer coefficient by various methods
 
Introduction to analytical instrumentation.
Introduction to analytical instrumentation.Introduction to analytical instrumentation.
Introduction to analytical instrumentation.
 
Jurnalku pompa
Jurnalku pompaJurnalku pompa
Jurnalku pompa
 
ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...
ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...
ICPT CMPUG 2018: A New Method for Determining the Size Distribution of Partic...
 
ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...
ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...
ICPT CMPUG 2018 Kanomax FMT A New Method for Determining of Particles in CMP ...
 
How can identify sensitivity of hydraulic characteristics of irrigation systems?
How can identify sensitivity of hydraulic characteristics of irrigation systems?How can identify sensitivity of hydraulic characteristics of irrigation systems?
How can identify sensitivity of hydraulic characteristics of irrigation systems?
 
Cfd analaysis of flow through a conical exhaust
Cfd analaysis of flow through a conical exhaustCfd analaysis of flow through a conical exhaust
Cfd analaysis of flow through a conical exhaust
 
Methods of particle size measrement (032)
Methods of particle size measrement (032)Methods of particle size measrement (032)
Methods of particle size measrement (032)
 
Ppt HADJI.pptx
Ppt HADJI.pptxPpt HADJI.pptx
Ppt HADJI.pptx
 
PPT - Electronics Industry Wastewater
PPT - Electronics Industry WastewaterPPT - Electronics Industry Wastewater
PPT - Electronics Industry Wastewater
 
A Novel Method for Measuring the Sizes and Concentrations
A Novel Method for Measuring the Sizes and ConcentrationsA Novel Method for Measuring the Sizes and Concentrations
A Novel Method for Measuring the Sizes and Concentrations
 
jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...
jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...
jove-protocol-54414-a-system-to-create-stable-nanoparticle-aerosols-from-nano...
 
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
 

RMS- Optimization of Sampling Systems

  • 1. SME Associates LLC Providing Innovative Solutions RMS- OPTIMIZATION OF SAMPLING SYSTEMS JAMES P. MENGE PE, CHP 1
  • 2. Background  Every day various quantities of particulates, vapors, gases and radionuclides are discharged to the environment from various power generation plants and production facilities.  In general, the airborne effluent from nuclear power plants is discharged continuously through one or more vents or stacks of various heights. 2
  • 3. Background (cont’d)  The released airborne radioactive pollutants can be summarized into the following categories:  Gaseous  Vapor  Particulate  The radionuclides are produced by a result of two processes:  The first process is the formation of fission products, which are produced when uranium atoms in the fuel are split.  The second process is activation, which occurs when atoms of other material within the system are made radioactive by neutron bombardment. 3
  • 4. Key Terms • A term used as a single dimension to describe a particle size in a fluid medium. Aerodynamic Equivalent Diameter (AED) • The particle size distribution curve relating to one size particleMonodisperse • Dimension less number that relates variables describing flow, velocity, density and viscosity.Reynolds Number • The percent of particulate that is transported from the nozzle to the collection media.Transport Efficiency • The region of Reynolds numbers between laminar (<2500) and turbulent flow (>4000) which relates variables describing flow, velocity, density and viscosity. Transition Region 4
  • 5. System Description  The system draws a continuous air sample from the sampling probe located high in the effluent stack.  The air sample is drawn through the sample lines to a series of filters consisting of a particulate filter, an iodine filter, a noble gas chamber and a pump then discharged to the stack. 5
  • 6. Sampling Systems FAQ’s  Is there one “Universal” monitoring system configuration?  No. Various monitoring system configurations are used by the nuclear power plant operators or utilities to comply with NUREG 0737 and Reg Guide 1.97.  Why do the sampling systems have problems?  These sampling systems can have inherent problems associated with representative sampling because of the complexity and length of the sampling line.  How effective are the sampling systems?  One utility initiated a program to measure the effectiveness of the sampling systems and found several mechanical problems (fans, baffles, probes, etc.) that affected their effluent monitoring program.  What did reviews of the stacks show?  Reviews performed for stacks found that the stack flows and the flow profiles were significantly different than the design flows used in their emission calculations. 6
  • 7. Sampling System FAQ’s (cont’d)  What is the purpose of a sample system model?  A sample system model provides an insight of which factors can influence the sample transport efficiency of a sampling system.  The sample flow velocity (v) is an important factor in the transport efficiency of particles through a sampling system.  What are the various design parameters, and what do they do?  The sample flow rate, tubing diameter and Reynolds Number are design parameters that directly determine the flow velocity through the sample system 7
  • 8. Particle Transmission Efficiency – Fx of Sample Flow & Reynolds Number 8
  • 9. Sampling System Maintenance  Perform a maintenance check on the sampling system actual pump flow variance  Check each probe and sample line for cleanliness.  Check system installation for the number of bends and bend curvature radius.  Higher transport efficiencies can be achieved when sampling line installations minimize flow direction changes.  Check Moisture content residual in sampling lines  Pressure test for Air-Leakage within Sample lines  A periodic check of the flow profile should be performed to check the effluent stream characteristics for sampling location. 9
  • 10. Sampling Point Challenges  The sampling point available for use may not provide a valid representation sample of the effluent.  A flow profile should be generated for each sample point location. This ensures that under varying plant conditions, the sample point is representative of the system stream. 10
  • 11. RMS: A Dynamic System  Flow rate and tubing diameter will affect transport efficiency based on particle sizing, plate out and impaction.  The transport efficiency of particles through a sample line may vary by 50% or more due to sample flow rate, and tubing diameter.  The RMS accuracy increases by reducing the sampling error and the extent of the scaling factors used to determine the particulate effluent release.  The effluent particulate monitoring repeatability increases due to the transport efficiency being optimized. 11
  • 12. Transport Efficiency  The transport efficiency is a function of particle size: as the particle size increases, the transport efficiency decreases. The median particle aerodynamic size should be determined for the distribution range of the mixture.  The limitation of the sample transport efficiency of the radiation monitoring sampling system is that it is based on a particular particle size and not the mixture. 12
  • 13. Optimization of Design Parameters  The transmission of a 5μm AED particle with a density of 1.5 g/cm3 drawn through the sample system model at 56.630 l/min yields only a 26% transmission efficiency.  The transmission efficiency of a particle is a function of the sample tube diameter. The optimum internal diameter for this sample system model with the design flow of 56.630 l/min is 22.926 mm.  The sample line transmission efficiency for this sample system model can be increased to 27% for a 5μm AED particle with a density of 1.5 g/cm3 by increasing the flow to approximately 70 l/min. The transmission efficiency of all particles less than 10μm AED is increased by raising the sample flow rate to 70 l/min. 13
  • 15. Optimization of Design Parameters  The transmission efficiency of particles is a function that is inversely proportionate to the particle density. As the particle density increases, the transmission efficiency decreases.  At the optimum sample flow rate of 70 l/min, the transmission efficiency for AED particle with a density range of 1.00 to 2.00 g/cm3 varies by only 0.1%.  The sampling system Reynolds number is in the transition region to achieve optimum transport efficiency. 15
  • 16. Recommendations: Sampling System  Perform an analysis of the sample stream to determine the range of particle sizes and density.  Develop a model for the sampling system to determine the transmission efficiency for the system based on particle size and density. It is not a monodisperse particle. • Determine the optimum sample flow rate for the sampling system. Do not rely on what the vendor or manufacturer has stated the sample flow rate should be for their radiation monitoring system skid. 16
  • 17. Filter Efficiency vs Particle Size • Review the filter collection media specifications to ensure the filter is sized appropriately for the flow velocity. 17
  • 18. Conclusions  The RMS Sampling System is key to proper system operation and dose measurement  RMS Sampling systems need periodic maintenance  It’s important to understand what the design parameters are for the sampling system  Performing detailed reviews will ensure system is not operationally challenged 18
  • 19. References  Menge J, (1997); “Optimization of Airborne Effluent Sampling Systems for Nuclear Power Plants”  Schmidt, A (1988); “ A Three-Part Strategy for Continuous Extractive Monitoring for Hazardous Particulate Emissions from Exhaust Stacks”  Schwendiman, Stegen, Glissmeyer (1975); “Methods and Aids for Assessing Particle Losses in Sampling Lines”  ANSI N13.1-1995; American National Standard Institute “Guide to Monitoring Releases of Airborne Radioactive Substances from Ducts and Stacks of Nuclear Facilities”.  NUREG 0737 (1983); “Clarification of TMI Action Plan Requirements”  US NRC Regulatory Guide 1.97 Rev 3 (1983); “Instrumentation for Light-Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident” 19
  • 20. RMS- Optimization of Sampling Systems Thank You SME Associates LLC Providing Innovating Solutions 20

Editor's Notes

  1. In the noble gas chamber, a sodium iodide scintillation detector is used to obtain the gross gamma count rate of the noble gases. The count rate is converted to a release rate (μCi/sec) by manually multiplying it by a stack flow conversion factor.
  2. The adequacy of the proposed location requires a flow profile to determine the flow velocity at several points. The flow measurements need to be taken during different operating process flow conditions.
  3. A Dynamic System will effect performance 2)The use of scaling factors has the tendency to overestimate the effluent release 3) This characteristic is important in predicting the performance of the sampling system to allow for standardization of the particle transport model for correlation to other radiation monitoring systems.
  4. Therefore, the recommendation is to provide a set of efficiencies for various particle sizes or a sample transport efficiency range based on particle size.
  5. AED -