This document provides installation and safety instructions for Hayward Pro Series high-rate sand filters, models S180T, S210T, S220T, and S244T. It contains warnings about hazards that could cause severe injury or death, including suction entrapment and electrical shock. It instructs users to follow all included instructions, only use recommended filter sand, and replace components after 10 years or if damaged.
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming ...Shane
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming pools, Operating Manual will teach you all that there is to know about this Intex pool Pump.
Access the comprehensive Iwaki America LK Series manual PDF to gain a deeper understanding of these high-quality metering pumps. This detailed manual provides step-by-step instructions for installation, operation, and maintenance of the LK Series pumps. Download the Iwaki America LK Series manual now to unlock the full potential of these versatile metering pumps for your industrial applications.
CrystalClear Pool Pump 637R manual, Intex KrystalClear pool filter pump manual.ported to slideshow by Corvoxpoolandspapparts.com your rare pool and spa parts super store! all trademarks are trademarks of the rightful owners. We only want to help our clients to have a backup of their pool manuals!
Colorado Water Purification US Water Fusion Backwashing Filter Manual 1110 8 14Water Works
Water Works is one of the largest providers of water treatment solutions in Colorado. Our experts repair, replace, and custom design solutions that are affordable for you. Our services include but are not limited to water filtration, water purification, reverse osmosis, water softening, ozone treatment, aeration, disinfection, chlorination, and chloramine removal. Contact us for a free water analysis! Visit us at: https://coloradowaterpurification.com/water-purification-water-softener-installation-in-colorado-springs/
Krystal Clear Model 637R filter Pump Manual for Intex and bestway swimming poolsShane
Manual for your Krystal Clear Pool pump model 637R, will work with bestway swimming pools look for our conversion manuals.ported to slideshow by Corvoxpoolandspapparts.com your rare pool and spa parts super store! all trademarks are trademarks of the rightful owners. We only want to help our clients to have a backup of their pool manuals!
ported to slideshow by Corvoxpoolandspapparts.com your rare pool and spa parts super store! all trademarks are trademarks of the rightful owners. We only want to help our clients to have a backup of their pool manuals!
RCM is a process used to identify what Preventive Maintenance or Condition Based Maintenance you need to implement so you get the Reliability you need from your equipment.
Doing Reliability Centered Maintenance (RCM) helps us take care of our equipment. And, taking care of our equipment is very much like taking care of ourselves.
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming ...Shane
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming pools, Operating Manual will teach you all that there is to know about this Intex pool Pump.
Access the comprehensive Iwaki America LK Series manual PDF to gain a deeper understanding of these high-quality metering pumps. This detailed manual provides step-by-step instructions for installation, operation, and maintenance of the LK Series pumps. Download the Iwaki America LK Series manual now to unlock the full potential of these versatile metering pumps for your industrial applications.
CrystalClear Pool Pump 637R manual, Intex KrystalClear pool filter pump manual.ported to slideshow by Corvoxpoolandspapparts.com your rare pool and spa parts super store! all trademarks are trademarks of the rightful owners. We only want to help our clients to have a backup of their pool manuals!
Colorado Water Purification US Water Fusion Backwashing Filter Manual 1110 8 14Water Works
Water Works is one of the largest providers of water treatment solutions in Colorado. Our experts repair, replace, and custom design solutions that are affordable for you. Our services include but are not limited to water filtration, water purification, reverse osmosis, water softening, ozone treatment, aeration, disinfection, chlorination, and chloramine removal. Contact us for a free water analysis! Visit us at: https://coloradowaterpurification.com/water-purification-water-softener-installation-in-colorado-springs/
Krystal Clear Model 637R filter Pump Manual for Intex and bestway swimming poolsShane
Manual for your Krystal Clear Pool pump model 637R, will work with bestway swimming pools look for our conversion manuals.ported to slideshow by Corvoxpoolandspapparts.com your rare pool and spa parts super store! all trademarks are trademarks of the rightful owners. We only want to help our clients to have a backup of their pool manuals!
ported to slideshow by Corvoxpoolandspapparts.com your rare pool and spa parts super store! all trademarks are trademarks of the rightful owners. We only want to help our clients to have a backup of their pool manuals!
RCM is a process used to identify what Preventive Maintenance or Condition Based Maintenance you need to implement so you get the Reliability you need from your equipment.
Doing Reliability Centered Maintenance (RCM) helps us take care of our equipment. And, taking care of our equipment is very much like taking care of ourselves.
An overview of the basic process to create an ALT using one of 6 different approaches. Slides used for presentation to the ASQ Silicon Valley evening meeting on Nov 15th 2017.
We work on projects to improve reliability. There may not be the field data immediately available. Let’s explore what you can do to improve the overall program while delivering on your project. Specifically, what’s with cost and procurement?
Detailed Information: As a reliability professional we often work with a team focused on improving the reliability of single product or system. We work with the resources and capabilities of the organization. For me a reliability project is one product or line, a program is the entire organization and lifecycle. We bring specific tools and knowledge, yet rely on the overall reliability culture of an organization to be successful
The overall reliability program may or may not have the field data, root cause analysis and other element of information that allow us to effectively solve problems for a specific project. In some cases we have to work to improve the overall program while striving to create a reliable product. Let’s explore what you should do when you are building a reliability model for a new project and would like to use previous reliability history.
If the data is not available what do you do? What are your options? Let’s discuss what happens when the procurement team consistently selects the least expensive and least reliable components. What are your options? You can and should change the way entire departments do business, for the good of the project and the organization. Let’s discuss the scope of your role as a reliability engineer.
This Accendo Reliability webinar originally broadcast on 19 May 2015.
Why You Should Replace Windows 11 with Nitrux Linux 3.5.0 for enhanced perfor...SOFTTECHHUB
The choice of an operating system plays a pivotal role in shaping our computing experience. For decades, Microsoft's Windows has dominated the market, offering a familiar and widely adopted platform for personal and professional use. However, as technological advancements continue to push the boundaries of innovation, alternative operating systems have emerged, challenging the status quo and offering users a fresh perspective on computing.
One such alternative that has garnered significant attention and acclaim is Nitrux Linux 3.5.0, a sleek, powerful, and user-friendly Linux distribution that promises to redefine the way we interact with our devices. With its focus on performance, security, and customization, Nitrux Linux presents a compelling case for those seeking to break free from the constraints of proprietary software and embrace the freedom and flexibility of open-source computing.
Generative AI Deep Dive: Advancing from Proof of Concept to ProductionAggregage
Join Maher Hanafi, VP of Engineering at Betterworks, in this new session where he'll share a practical framework to transform Gen AI prototypes into impactful products! He'll delve into the complexities of data collection and management, model selection and optimization, and ensuring security, scalability, and responsible use.
Essentials of Automations: The Art of Triggers and Actions in FMESafe Software
In this second installment of our Essentials of Automations webinar series, we’ll explore the landscape of triggers and actions, guiding you through the nuances of authoring and adapting workspaces for seamless automations. Gain an understanding of the full spectrum of triggers and actions available in FME, empowering you to enhance your workspaces for efficient automation.
We’ll kick things off by showcasing the most commonly used event-based triggers, introducing you to various automation workflows like manual triggers, schedules, directory watchers, and more. Plus, see how these elements play out in real scenarios.
Whether you’re tweaking your current setup or building from the ground up, this session will arm you with the tools and insights needed to transform your FME usage into a powerhouse of productivity. Join us to discover effective strategies that simplify complex processes, enhancing your productivity and transforming your data management practices with FME. Let’s turn complexity into clarity and make your workspaces work wonders!
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...UiPathCommunity
💥 Speed, accuracy, and scaling – discover the superpowers of GenAI in action with UiPath Document Understanding and Communications Mining™:
See how to accelerate model training and optimize model performance with active learning
Learn about the latest enhancements to out-of-the-box document processing – with little to no training required
Get an exclusive demo of the new family of UiPath LLMs – GenAI models specialized for processing different types of documents and messages
This is a hands-on session specifically designed for automation developers and AI enthusiasts seeking to enhance their knowledge in leveraging the latest intelligent document processing capabilities offered by UiPath.
Speakers:
👨🏫 Andras Palfi, Senior Product Manager, UiPath
👩🏫 Lenka Dulovicova, Product Program Manager, UiPath
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdfPeter Spielvogel
Building better applications for business users with SAP Fiori.
• What is SAP Fiori and why it matters to you
• How a better user experience drives measurable business benefits
• How to get started with SAP Fiori today
• How SAP Fiori elements accelerates application development
• How SAP Build Code includes SAP Fiori tools and other generative artificial intelligence capabilities
• How SAP Fiori paves the way for using AI in SAP apps
Removing Uninteresting Bytes in Software FuzzingAftab Hussain
Imagine a world where software fuzzing, the process of mutating bytes in test seeds to uncover hidden and erroneous program behaviors, becomes faster and more effective. A lot depends on the initial seeds, which can significantly dictate the trajectory of a fuzzing campaign, particularly in terms of how long it takes to uncover interesting behaviour in your code. We introduce DIAR, a technique designed to speedup fuzzing campaigns by pinpointing and eliminating those uninteresting bytes in the seeds. Picture this: instead of wasting valuable resources on meaningless mutations in large, bloated seeds, DIAR removes the unnecessary bytes, streamlining the entire process.
In this work, we equipped AFL, a popular fuzzer, with DIAR and examined two critical Linux libraries -- Libxml's xmllint, a tool for parsing xml documents, and Binutil's readelf, an essential debugging and security analysis command-line tool used to display detailed information about ELF (Executable and Linkable Format). Our preliminary results show that AFL+DIAR does not only discover new paths more quickly but also achieves higher coverage overall. This work thus showcases how starting with lean and optimized seeds can lead to faster, more comprehensive fuzzing campaigns -- and DIAR helps you find such seeds.
- These are slides of the talk given at IEEE International Conference on Software Testing Verification and Validation Workshop, ICSTW 2022.
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...DanBrown980551
Do you want to learn how to model and simulate an electrical network from scratch in under an hour?
Then welcome to this PowSyBl workshop, hosted by Rte, the French Transmission System Operator (TSO)!
During the webinar, you will discover the PowSyBl ecosystem as well as handle and study an electrical network through an interactive Python notebook.
PowSyBl is an open source project hosted by LF Energy, which offers a comprehensive set of features for electrical grid modelling and simulation. Among other advanced features, PowSyBl provides:
- A fully editable and extendable library for grid component modelling;
- Visualization tools to display your network;
- Grid simulation tools, such as power flows, security analyses (with or without remedial actions) and sensitivity analyses;
The framework is mostly written in Java, with a Python binding so that Python developers can access PowSyBl functionalities as well.
What you will learn during the webinar:
- For beginners: discover PowSyBl's functionalities through a quick general presentation and the notebook, without needing any expert coding skills;
- For advanced developers: master the skills to efficiently apply PowSyBl functionalities to your real-world scenarios.
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
Pushing the limits of ePRTC: 100ns holdover for 100 daysAdtran
At WSTS 2024, Alon Stern explored the topic of parametric holdover and explained how recent research findings can be implemented in real-world PNT networks to achieve 100 nanoseconds of accuracy for up to 100 days.
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
In his public lecture, Christian Timmerer provides insights into the fascinating history of video streaming, starting from its humble beginnings before YouTube to the groundbreaking technologies that now dominate platforms like Netflix and ORF ON. Timmerer also presents provocative contributions of his own that have significantly influenced the industry. He concludes by looking at future challenges and invites the audience to join in a discussion.
Observability Concepts EVERY Developer Should Know -- DeveloperWeek Europe.pdfPaige Cruz
Monitoring and observability aren’t traditionally found in software curriculums and many of us cobble this knowledge together from whatever vendor or ecosystem we were first introduced to and whatever is a part of your current company’s observability stack.
While the dev and ops silo continues to crumble….many organizations still relegate monitoring & observability as the purview of ops, infra and SRE teams. This is a mistake - achieving a highly observable system requires collaboration up and down the stack.
I, a former op, would like to extend an invitation to all application developers to join the observability party will share these foundational concepts to build on:
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™UiPathCommunity
In questo evento online gratuito, organizzato dalla Community Italiana di UiPath, potrai esplorare le nuove funzionalità di Autopilot, il tool che integra l'Intelligenza Artificiale nei processi di sviluppo e utilizzo delle Automazioni.
📕 Vedremo insieme alcuni esempi dell'utilizzo di Autopilot in diversi tool della Suite UiPath:
Autopilot per Studio Web
Autopilot per Studio
Autopilot per Apps
Clipboard AI
GenAI applicata alla Document Understanding
👨🏫👨💻 Speakers:
Stefano Negro, UiPath MVPx3, RPA Tech Lead @ BSP Consultant
Flavio Martinelli, UiPath MVP 2023, Technical Account Manager @UiPath
Andrei Tasca, RPA Solutions Team Lead @NTT Data
Epistemic Interaction - tuning interfaces to provide information for AI supportAlan Dix
Paper presented at SYNERGY workshop at AVI 2024, Genoa, Italy. 3rd June 2024
https://alandix.com/academic/papers/synergy2024-epistemic/
As machine learning integrates deeper into human-computer interactions, the concept of epistemic interaction emerges, aiming to refine these interactions to enhance system adaptability. This approach encourages minor, intentional adjustments in user behaviour to enrich the data available for system learning. This paper introduces epistemic interaction within the context of human-system communication, illustrating how deliberate interaction design can improve system understanding and adaptation. Through concrete examples, we demonstrate the potential of epistemic interaction to significantly advance human-computer interaction by leveraging intuitive human communication strategies to inform system design and functionality, offering a novel pathway for enriching user-system engagements.
zkStudyClub - Reef: Fast Succinct Non-Interactive Zero-Knowledge Regex ProofsAlex Pruden
This paper presents Reef, a system for generating publicly verifiable succinct non-interactive zero-knowledge proofs that a committed document matches or does not match a regular expression. We describe applications such as proving the strength of passwords, the provenance of email despite redactions, the validity of oblivious DNS queries, and the existence of mutations in DNA. Reef supports the Perl Compatible Regular Expression syntax, including wildcards, alternation, ranges, capture groups, Kleene star, negations, and lookarounds. Reef introduces a new type of automata, Skipping Alternating Finite Automata (SAFA), that skips irrelevant parts of a document when producing proofs without undermining soundness, and instantiates SAFA with a lookup argument. Our experimental evaluation confirms that Reef can generate proofs for documents with 32M characters; the proofs are small and cheap to verify (under a second).
Paper: https://eprint.iacr.org/2023/1886
zkStudyClub - Reef: Fast Succinct Non-Interactive Zero-Knowledge Regex Proofs
RCA Seminar, Day 1, Greg Swartz, Ops A La Carte
1. IS210T-06
Rev. A
OWNER’S MANUAL
INSTALLATION, OPERATION & PARTS
MODELS S180T, S210T, S220T, S244T
PRO™ SERIES HIGH-RATE SAND FILTERS
Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe
injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the
following signal words and be alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property damage and if
ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage
and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
SAVE THIS INSTRUCTION MANUAL
Use only High Rate Sand No. 20 Silica Sand (.45mm - .55mm)
HAYWARD POOL PRODUCTS, INC.
620 Division Street Elizabeth, NJ 07207 Tel: 908-351-5400
WWW.HAYWARDPOOL.COM
2. Page 2 of 8 MODEL S180T, S210T, S220T, S244T IS210T-06 Rev A
- WARNING - Read and follow all instructions in this owner’s manual and on the equipment. Failure to
follow instructions can cause severe injury and/or death.
WARNING – Suction Entrapment Hazard.
Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or unsecured can cause severe injury
and/or death due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover.
Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked,
missing, or not securely attached can result in a mechanical bind or swelling of the limb.
Body Suction Entrapment- A negative pressure applied to a large portion of the body or limbs can result in an entrapment.
Evisceration/ Disembowelment - A negative pressure applied directly to the intestines through an unprotected suction outlet sump or
suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment.
Mechanical Entrapment- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a
suction outlet cover resulting in mechanical entrapment.
WARNING - To Reduce the risk of Entrapment Hazards:
o When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be
installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [1 meter] apart, as
measured from near point to near point.
o Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user.
o Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.
o The maximum system flow rate shall not exceed the flow rating of as listed on Table 2.
o Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.
o Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
o In addition two or more suction outlets per pump installed in accordance with latest NSPI, IAF Standards and CPSC guidelines, follow all
National, State, and Local codes applicable.
o Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
WARNING – Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction
outlets can result in an increase potential for suction entrapment as described above.
WARNING – Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other
material can result in an increase potential for suction entrapment as described above.
WARNING – Suction outlet components have a finite life, the cover/grate should be inspected frequently and replaced
at least every ten years or if found to be damaged, broken, cracked, missing, or not securely attached.
CAUTION – Components such as the filtration system, pumps and heater must be positioned so as to prevent their
being used as means of access to the pool by young children.
WARNING – Never operate or test the circulation system at more than 40 PSI.
CAUTION – All electrical wiring MUST be performed by a qualified professional, and MUST conform to local codes
and regulations.
WARNING – Never change the filter control valve position while the pump is running.
WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during
start up, normal operation, and after pump shut off. Stand clear of circulation system equipment during pump start up. Failure to
follow safety and operation instructions could result in violent separation of the pump housing and cover, and/or filter housing and
clamp due to pressure in the system, which could cause property damage, severe personal injury, or death. Before servicing pool and
spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before
starting system pump, all system valves must be set in a position to allow system water to return back to the pool. Do not change filter control valve
position while system pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief
valve until a steady stream of water (not air or air and water) is discharged.
WARNING – Separation Hazard. Failure to follow safety and operation instructions could result in violent separation of
pump and/or filter components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing
pool and spa circulation system, filters manual air relief valve must be in open position. Do not operate pool and spa circulation system
if a system component is not assembled properly, damaged, or missing. Do not operate pool and spa circulation system unless filter
manual air relief valve body is in locked position in filter upper body.
WARNING – Electrical Ground motor before connecting to electrical power supply. Failure to ground pump motor can
cause serious or fatal electrical shock hazard.
WARNING – Do NOT ground to a gas supply line.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3. Page 3 of 8 MODEL S180T, S210T, S220T, S244T IS210T-06 Rev A
WARNING – To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
WARNING – Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death. To reduce the
risk of electric shock, see installation instructions and consult a professional electrician on how to bond pump. Also, contact a licensed electrician for
information on local electrical codes for bonding requirements.
Your Hayward Pro Series high-rate sand filter is a high
NOTE: Check to confirm all laterals are in the down
performance, totally corrosion-proof filter that blends superior
position before loading with sand. (See Figure A.)
flow characteristics and features with ease of operation. It
represents the very latest in high-rate sand filter technology. It d. Carefully pour in correct amount and grade of filter
is virtually foolproof in design and operation and when sand, as specified on Table 1. (Be sure center pipe
installed, operated and maintained according to instructions, remains centered in opening). Sand surface should be
your filter will produce clear, sparkling water with only minimal leveled and should come to within 6" of the top of the
attention and care. filter tank. Remove sand shield from internal pipe.
HOW IT WORKS 4. Assemble Filter Control Valve to filter tank.
Your filter uses special filter sand to remove dirt particles from a. Loosely pre-assemble both halves of the clamp with one
pool water. Filter sand is loaded into the filter tank and screw and one nut, turning the nut 2 or 3 turns. Do not
functions as the permanent dirt removing media. The pool tighten. Wipe filter flange clean.
water, which contains suspended dirt particles, is pumped b. Insert Filter Control Valve (with valve/flange 0-ring in
through your piping system and is automatically directed by the place) into the tank neck, taking care that the center pipe
patented filter control valve to the top of the filter tank. As the slips into the hole in the bottom of the valve. Install clamp
pool water is pumped through the filter sand, dirt particles are around tank and valve flange and assemble second screw
trapped by the sand bed, and filtered out. The cleaned pool and nut. Tighten just enough so that the valve may be
water is returned from the bottom of the filter tank, through the rotated on tank for final positioning.
control valve and back to the pool through the piping system. c. Wrap two turns of Teflon pipe sealant tape manufactured
This entire sequence is continuous and automatic and provides for plastic pipe on the ¼” NPT male end of gauge.
total recirculation of pool water through your filter and piping Carefully screw pressure gauge, into 1/4"NPT tapped
system. hole in valve body. Do not over tighten.
After a period of time, the accumulated dirt in the filter causes d. Connect pump to control valve opening marked PUMP
a resistance to flow, and the flow diminishes. This means it is according to instructions. After connections are made,
time to clean (backwash) your filter. With the control valve in tighten valve flange clamp with screwdriver, tapping
the backwash position, the water flow is automatically reversed around clamp with screwdriver handle to help seat valve
through the filter so that it is directed to the bottom of the tank, flange clamp.
up through the sand, flushing the previously trapped dirt and 5. Make return to pool pipe connection to control valve
debris out the waste line. Once the filter is backwashed opening marked RETURN and complete other necessary
(cleaned) of dirt, the control valve is manually resequenced to plumbing connections, suction lines to pump, waste, etc.
Rinse, and then Filter, to resume normal filtering. 6. Make electrical connections to pump per pump instructions.
INSTALLATION 7. To prevent water leakage, be sure winter drain cap is
Only simple tools (screwdriver and wrenches), plus pipe securely in place and all pipe connections are tight.
sealant for plastic adapters, are required to install and/or
service the filter.
1. The filter system should be installed, not more than 6 feet
above pool water level, on a level concrete slab, very firm
ground, or equivalent, as recommended by your pool
dealer. Position the filter so that the piping connections,
control valve and winter drain are convenient and
accessible for operation, service and winterizing.
2. Assemble pump and pump mounting base, No.
S160TPAK1, or S160TPAK3 (if supplied) to the filter
according to instructions packed with the base.
3. Loading sand media. Filter sand media is loaded through
the top opening of the filter.
a. Loosen flange clamp and remove Filter Control Valve (if
previously installed).
b. Cap internal pipe with sand shield to prevent sand from
entering it. Be sure pipe is securely in place in bottom
underdrain hub.
c. We recommend filling tank approximately 1/2 way with
water to provide a cushioning effect when the filter sand
is poured in. This helps protect the underdrain laterals
from excessive shock. (Be sure the winter drain cap is
securely in place on drain pipe).
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4. Page 4 of 8 MODEL S180T, S210T, S220T, S244T IS210T-06 Rev A
INITIAL START-UP OF FILTER RINSE—After backwashing, with pump off, set valve to
1. Be sure correct amount of filter sand media is in tank and RINSE. Start pump and operate for about 1/2 to 1 minute.
that all connections have been made and are secure. This ensures that all dirty water from backwashing is
2. Depress Vari-Flo control valve handle and rotate to rinsed out of the filter to waste, preventing possible return
BACKWASH* position. (To prevent damage to control valve to the pool. Stop pump, set valve to FILTER, and start
seal, always depress handle before turning.)
pump for normal filtering.
3. Prime and start pump according to pump instructions (be
sure all suction and return lines are open), allowing the filter
WASTE—To bypass filter for draining or lowering water
tank to fill with water. level and for vacuuming heavy debris directly to waste.
RECIRCULATE—Water is recirculated through the pool
WARNING: ALL SUCTION AND system, bypassing the filter.
DISCHARGE VALVES MUST BE OPEN WHEN CLOSED—Shuts off flow from pump to filter.
STARTING THE SYSTEM. FAILURE TO DO VACUUMING—Vacuuming can be performed directly into
SO COULD CAUSE SEVERE PERSONAL the filter. When vacuuming heavy debris loads, set valve
INJURY. to WASTE position to bypass the filter and vacuum
directly out to waste.
Once water flow is steady out the waste line, run the pump for WINTERIZING
at least 2 minutes. The initial back-washing of the filter is 1. Completely drain tank by unscrewing drain cap at
recommended to remove any impurities or fine sand particles base of filter tank. Leave cap off during winter.
in the sand media.
4. Turn pump off and set valve to RINSE position. Start pump
and operate until water in sight glass is clear—about 1/2 to 1 2. Depress Vari-Flo control valve handle and rotate so as
minute. Turn pump off, set valve to FILTER position and to set pointer on valve top between any two positions.
restart pump. Your filter is now operating in the normal filter This will allow water to drain from the valve. Leave
mode, filtering particles from the pool water. valve in this "inactive" position.
5. Adjust pool suction and return valves to achieve desired
flow. Check system and filter for water leaks and tighten 3. Drain and winterize pump according to pump
connections, bolts, nuts, as required. instructions.
6. Note the initial pressure gauge reading when the filter is
clean. (It will vary from pool to pool depending upon the
pump and general piping system). As the filter removes dirt
SERVICE & REPAIRS
and impurities from the pool water, the accumulation in the Consult your local authorized Hayward dealer or service
filter will cause the pressure to rise and flow to diminish. center. No returns may be made directly to the factory
When the pressure gauge reading is 8-10 PSI (0.55-0.69 without the expressed authorization of Hayward Pool
BAR) higher than the initial "clean" pressure you noted, it is Products, Inc.
time to backwash (clean) the filter (see BACKWASH under
Filter Control Valve Functions.)
NOTE: During initial clean-up of the pool water it may be PLEASE REALIZE.. .
necessary to backwash frequently due to the unusually Pure, clear swimming pool water is a combination of two
heavy initial dirt load in the water. factors—adequate filtration and proper water chemistry
KEEP SAFETY LABELS IN GOOD CONDITION AND balance. One without the other will not give the clean
REPLACE IF MISSING OR DAMAGED. water you desire.
IMPORTANT: To prevent unnecessary strain on piping
system and valving, always shut off pump before
switching Filter Control Valve positions. Your filter system is designed for continuous operation.
However, this is not necessary for most swimming pools.
To prevent damage to the pump and filter and for proper
You can determine your filter operation schedule based
operation of the system, clean pump strainer and
on your pool size and usage. Be sure to operate your
skimmer baskets regularly.
filtration system long enough each day to obtain at least
one complete turnover of your pool water.
FILTER CONTROL VALVE FUNCTIONS
FILTER—Set valve to FILTER for normal filtering. Also
use for regular vacuuming. To properly sanitize your pool, maintain a free chlorine
BACKWASH—For cleaning filter. When filter pressure level of 1 to 3 ppm and a pH range of 7.2 to 7.6.
gauge rises 8-10 PSI (0.55-0.69 BAR) above start-up Insufficient chlorine or an out of balance pH level will
(clean pressure): permit algae and bacteria to grow in your pool and make
Stop the pump, set valve to BACKWASH. Start pump it difficult for your filter to properly clean the pool water.
and backwash until water in sight glass is clear.
Approximately 2 minutes or less depending on dirt
*NOTE: For new concrete or gunite pools, or where there is a large amount of
accumulation. Proceed to RINSE. plaster dust or debris—start filter in FILTER position (not BACKWASH) to
prevent clogging of underdrain laterals.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5. Page 5 of 8 MODEL S180T, S210T, S220T, S244T IS210T-06 Rev A
SPECIFICATIONS
EFFECTIVE MAXIMUM REQUIRED CLEARANCE MEDIA REQUIRED
MODEL FILTRATION WORKING
SIDE ABOVE TYPE AMOUNT
NUMBER AREA PRESSURE
2 2
FT M PSI BAR INCH MM INCH MM FILTER LBS KG
SAND**
S180T 1.75 .16 50 3.45 18 460 18 460 0.45-0.55mm 150 65
S210T 2.2 .20 50 3.45 18 460 18 460 0.45-0.55mm 200 90
S220T 2.6 .25 50 3.45 18 460 18 460 0.45-0.55mm 250 115
S244T 3.1 .29 50 3.45 18 460 18 460 0.45-0.55mm 300 135
TABLE 1 **Also known as No. 20 Silica Sand.
PARTS
Models S180T, S210T, S220T, S244T
REF PART DESCRIPTION NO.
NO NO. REQ
1 SP0714T Vari-Flo XL Control Valve 1 ½” 1
2 ECX270861 Pressure Gauge 1
3 GMX600F Valve/Tank O-ring 1
4 GMX600NM Flange Clamp 1
5 SX202S Sand Shield –2004 Corrugated 1
Design
6a SX180DA Folding Lateral Assy S180T 1
6b SX210DA Folding Lateral Assy S210T 1
6c SX220DA Folding Lateral Assy S220T 1
6d SX244DA Folding Lateral Assy S244T 1
7a SX180AA2 Filter tank Assy less valve & clamp 1
7b SX210AA1
7c SX220AA1
7d SX244AA1
8a SX200Q Lateral (Screw in) Prior 2005(18”) 10
8b SX200QN Lateral (One piece) (18”) 10
8c SX240D Lateral (Screw in) Prior to 2005 10
8d SX240DN Lateral (One piece) 10
9a SX180HG Drain Cap Kit (Round) 1
9b SX180LA Drain Cap Assy 1
10 SX200J System Base 1
FIGURE B
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6. Page 6 of 8 MODEL S180T, S210T, S220T, S240T IS210T-06 Rev A
MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE
Pipe Size Flow rate Pipe Size Flow rate Pipe Size Flow rate
[mm] GPM [Liter/Min] [mm] GPM [Liter/Min] [mm] GPM [Liter/Min]
1” 20 1 ½” 45 2 ½” 110
[32] [75] [50] [170] [75] [415]
1 ¼” 30 2” 80 3” 160
[40] [110] [63] [300] [90] [600]
TABLE 2
PRODUCT REGISTRATION
(Retain For Your Records)
DATE OF INSTALLATION ____________________
PURCHASED FROM _______________________
MODEL _______________ SERIAL NUMBER _______________________
▲Retain this Warranty Certificate in a safe and convenient location for your records.
PROBLEM SOLVING LIST
LOW WATER FLOW SHORT FILTER CYCLES POOL WATER WON'T CLEAR UP
REMEDY 1. Check skimmer and pump 1. Check for algae in pool and 1. Check chlorine, pH and total
strainer baskets for debris. superchlorinate as required. alkalinity levels and adjust
as required.
2. Check for restrictions in 2. Be sure chlorine and pH
intake and discharge lines. levels are in proper range 2. Be sure flow rate through
(adjust as required). filter is sufficient.
3. Check for air leak in intake
line (indicated by bubbles 3. Check surface of filter sand 3. Operate filter for longer periods.
returning to pool). for crusting or caking
(remove 1 " of sand if 4. Be sure Vari-Flo valve is set
4. Backwash filter. necessary). on "Filter" position.
POOL CHEMISTRY GUIDELINES
ACTION REQUIRED TO CORRECT POOL CHEMISTRY
SUGGESTED POOL CHEMISTRY LEVELS
TO RAISE TO LOWER
pH 7.2 to 7.6 Add Soda Ash Add Muriatic Acid or Sodium Bisulphate
TOTAL ALKALINITY 100 to 130 ppm Add Sodium Bicarbonate Add Muriatic Acid
CHLORINE (UNSTABILIZED) 0.3 to 1.0 ppm Add Chlorine Chemical No action - chlorine will naturally dissipate
CHLORINE (STABILIZED) 1.0 to 3.0 ppm Add Chlorine Chemical No action - chlorine will naturally dissipate
CHLORINE STABILIZER 40 to 70 ppm Dilution - partially drain & refill pool with water
Add Stabilizer
(Cyanuric Acid) that has not been treated with Cyanuric Acid.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS