SlideShare a Scribd company logo
CryoStamp
CryoStamp is based on Cryoelectrophoresis, implemented Combination therapy that potentially useable
coupled with CryoTherapy, Hot Therapy, Iontophoresis, Erectric Medium Frequency Therapy and hot/cold
electrical stimulation.
CryoStamp is builded the final one on research and development for three years, establish a prominent
effect as a new idea of medical instrument for pain. It is a patented article and has applied for a international
patent.
a theory information file : Nature - 2001. 9 / number.413
Well-balanced penetration on the tissue , Inhibition of exothermic reaction , Anti-inflammatory effect ,
Relax Tight Muscles and analgesia effect , Improve Circulation of local area
Stamp
LCD Display
Detachable Hand Probe
Input Touch Key
Intensity Control Knob
Pad Connection Socket
Hand Probe Hanger
CryoStamp
Rear of the Main Body
Ventilation
AC Socket Power Switch
<Application>
This device applies the cooling stimulus and heating
stimulus to the skin and is combination beauty equipment
aimed for helping manage the cosmetics well by applying
the bio-current like micro-current and low voltage stimuli.
New Medicare therapy
 NO NEEDLE MESO THERAPY
 Cryo Stamp Galvanic Needle Therapy
 FACE & BODY LIFTING
 VITAMIN C CARE
 SKIN TONE & TEXTURE
 LASER POST CARE
1) Low Tension Polarity Pad : Length 1,400mm
2) Power Cord Length : 3,000mm
3) Dimensions : 390mm×285mm×116mm[W×D×H]
4) Length of Hand Probe : 1,600mm
5) Weight : 5kg
1. Preparations before Use
(1) Check if the power switch is OFF and then connect the power cord.
(2) Check the cooling/heating catheter electrode of the main unit and main unit for the foreign substances and
clean them up, if any.
(3) Check if the components are properly connected.
* When using a pad, connect to the connecting socket on the side.
2. Switching Power ON
(1) Connect the power cord which is on the rear. (AC 100V ~ 220V, 50Hz ~ 60Hz)
(2) Press the power switch to switch the power ON.
(3) After the buzzer beeps three times, the Display is shown as below.
---> It must be displayed without blinking.
* However, if the LED around the Intensity Control Knob in the center blinks, all of the Input Keys ( ∧, F, ∨ ) do not
activate and the equipment stops.
* In that case, rotate the Intensity Control Knob counterclockwise until it clicks and the blinking will stop.
---> This situation is the function of Auto Zero Start for the safety of the equipment, which is not out of order.
Touch-type Input Keys are positioned under the Intensity Control Knob.
How to useCryoStamp
3. LCD Display
(1) If the power is switched ON, basically the default value will be displayed on the Display. The default
value cannot be changed and is displayed whenever the power is switched ON.
Temperature -5℃
Time 15 Minute
Mode MC
Polarity (-)
Intensity All level displays are OFF
(2) Setting Function Range
Temperature
-15℃ ~ 20℃ (automatically displayed as 'Cool')
21℃ ~ 29℃ Range that is not used
30℃ ~ 40℃ (automatically displayed as 'Hot')
Time 0 ~ 60 min.
Mode MC or MF
Polarity (-) or (+)
Intensity 24-step level display
How to useCryoStamp
How to use
4. Input Touch Key
There are 3 kinds of keys in the Input Touch Key. Slightly touch the key of the mode desired and the value will be input.
(1) Setting Temperature
Touch to make the letters of 'Temperature' blink.
Touch , to adjust the temperature to the desired value.
(2) Setting Time
Touch to make the letters of 'Time' blink.
Touch , to adjust the time to the desired value.
(3) Setting Mode
Touch to make the letters of 'Mode' blink.
If is touched, the mode is set to MC.
If is touched, the mode is set to MF.
(4) Setting Polarity
Touch to make the letters of 'Polarity' blink.
If is touched, the mode is set to (-).
If is touched m the mode is set to ⊕.
(5) Storing the Set Value
In order to store the Temperature and Time changed at (1) and (2) above, press and keys simultaneously and then a beep
sounds once a second. If they are touched for over 3 seconds and then released, the set value shall be stored and can be
used repeatedly afterwards. The value does not change even when the power is OFF.
(6) Accessing the Stored Value
In order to access the value stored, press and keys simultaneously and then a beep sounds once a second. If they are
touched for over 3 seconds and then released, the user can access the stored value and, if touched again, the value will be
changed to the default value. The stored and default values are displayed in turn repeatedly every time the keys are pressed.
CryoStamp
5. Descriptions of Each Function
(1) Temperature
The temperature is basically set at -05℃ as the default value which is most normally used, and the user can adjust the
temperature before using. If the changed temperature is not stored at this time, the value will be lost after a cosmetic
procedure or a treatment. The storing method is explained in the 'Storing in the Set Value.'
(2) Time
The Time is set in minutes and basically set at 15 minutes as the default value which is mostly normal duration of a
procedure and the user can adjust the time before using. If the changed time is not stored at this time, the value will be lost
after a cosmetic procedure or a treatment. The storing method is explained in the 'Storing in the Set Value.'
(3) Pulse Form Mode
There are two pulse form modes of MC and MF.
The MC mode applies the micro-current to the human body and helps the ionized solution to be absorbed well into the skin.
(max. current: 100uA)
The MF mode performs the function to help the ionized solution to be absorbed well into the skin by applying the pulse
modulated low-voltage (max. voltage: 5-volt) to the human body. (The intensity becomes stronger as it gets closer toward
100%. As there are differences in the electric irritability according to the human body, a special caution is required to prevent
the electric shock.)
(4) Polarity
There are two polarities of (-) and ⊕.
When using (-) polarity, the polarity for the hand probe is (-) and for the pad is ⊕when with the product of which solution is
ionized in (-) polarity. (Most of the cosmetics are (-) polarity.)
When using ⊕ polarity, the polarity for the hand probe is ⊕ and for the pad is (-) when used with the product of which
solution is ionized in ⊕ polarity.
Selection of polarity can be used only for the electric stimuli of MC and MF modes and they function only when the pad is
connected. That is, the selections of mode and polarity do not work when the pad is disconnected.
Function ExplanationCryoStamp
6. Operation
(1) Operation by the Preset Value Stored
If the power is switched ON, the screen displays the default values. If the Intensity Control Knob is turned on
immediately at this time, the equipment does not work. Be sure to touch the F key to change to the stored value
and one of the functioning letters shall blink. If the Intensity Control Knob is set to ON position in this status, the
equipment starts operating.
(2) Operation by the Default Value
Before turning on the Intensity Control Knob for the operation by the setting value, follow the Accessing the
Stored Value of the above 4-(6) to access the default value and the turn on the Intensity Control Knob to operate
the equipment.
(3) Operation by the Changed Value
To run the equipment only one time by the changed value, set the value in the Input Touch Key of the 4 and the
turn on the Intensity Control Knob to operate the equipment.
(4) Repeated Operation
In order to repeat the above (1), (2) and (3), turn off the Intensity Control Knob after the operation is over and
the value shall disappear to be changed to the stored value.
7. Completion of Operation
If the preset time is over, the time display shows 00 and the buzzer signalling the end beeps 5 times and all
outputs are stopped with the LED around the Intensity Control Knob blinks. If the Lever is turned OFF, the
blinking stops.
Function ExplanationCryoStamp
8. Warning for Malfunction
If the temperature gets too high enough to cause the burn or something hazardous during operation, the
equipment stops operating to prevent the safety accidents, the buzzer beeps and the LED around the Intensity
Control Knob keeps blinking. At this time, turn off the Intensity Control Knob and, after stopping the
equipment about for 10 minutes for its stabilization, re-operate the equipment. (if the problems continue
afterwards, call for a qualified engineer for the safety check.)
9. Cautions for Operation
① Customers should not be connected, in any case, to the grounded part that the current might flow.
② Do not use this equipment for the customer who is wearing a pacemaker.
③ Do not use this equipment for a cancer patient or a patient with a similar disease.
④ The equipment should be used only by the person who received the specialized training.
⑤ Be careful of the followings in process of operating the equipment.
- Check if anything abnormal with the customer or the equipment is found during operation.
- If anything wrong with the customer or the equipment is found, stop operating the equipment and check the
customer's safety. Re-start operating the equipment only when there is no disorder after checking up the status
of the customer and the equipment.
Function ExplanationCryoStamp
Protection type and level for electric
shock : Class ll Equipment
Input voltage : 110~ 220VAC/50~60Hz
Output voltage(device power) : 100W
Frequency : 10KHZ±10%,Sine wave / DC
Output voltage : 42V p-p / 1V p-p
Electrification method : Gap electrification
Timer : 1~60minutes , set a standard point
by 1minute unit
Safety Device : Zero Start
Temperature : -10˚C~45˚C
Specifications
Combination Therapy System
CryoStamp

More Related Content

What's hot

DALI constant current dimmable driver EULP50D-1HMC-0
DALI constant current dimmable driver EULP50D-1HMC-0DALI constant current dimmable driver EULP50D-1HMC-0
DALI constant current dimmable driver EULP50D-1HMC-0
Shanghai Euchips Industrial Co.,Ltd.
 
Liemke Merlin Clip On 35 Instruction Manual | Optics Trade
Liemke Merlin Clip On 35 Instruction Manual | Optics TradeLiemke Merlin Clip On 35 Instruction Manual | Optics Trade
Liemke Merlin Clip On 35 Instruction Manual | Optics Trade
Optics-Trade
 
HEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 ManualHEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 Manual
Domotica daVinci
 
ZMPCRM073000.12.01 User's Manual
ZMPCRM073000.12.01 User's ManualZMPCRM073000.12.01 User's Manual
ZMPCRM073000.12.01 User's ManualPainezee Specialist
 
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable BatteryPM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
Devendra Tiwari 7838896746
 
E 043 opt shr user manual
E 043 opt shr user manualE 043 opt shr user manual
E 043 opt shr user manual
E-beauty
 
E 070 lipo laser slimming machine
E 070 lipo laser slimming machineE 070 lipo laser slimming machine
E 070 lipo laser slimming machine
E-beauty
 
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Domotica daVinci
 
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable batteryPm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Devendra Tiwari 7838896746
 

What's hot (12)

DALI constant current dimmable driver EULP50D-1HMC-0
DALI constant current dimmable driver EULP50D-1HMC-0DALI constant current dimmable driver EULP50D-1HMC-0
DALI constant current dimmable driver EULP50D-1HMC-0
 
Liemke Merlin Clip On 35 Instruction Manual | Optics Trade
Liemke Merlin Clip On 35 Instruction Manual | Optics TradeLiemke Merlin Clip On 35 Instruction Manual | Optics Trade
Liemke Merlin Clip On 35 Instruction Manual | Optics Trade
 
HEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 ManualHEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 Manual
 
ZMPCRM073000.12.01 users Manual
ZMPCRM073000.12.01 users ManualZMPCRM073000.12.01 users Manual
ZMPCRM073000.12.01 users Manual
 
ZMPCRM073000.12.01 User's Manual
ZMPCRM073000.12.01 User's ManualZMPCRM073000.12.01 User's Manual
ZMPCRM073000.12.01 User's Manual
 
ZMPCRM073000.12.01 Users Manual
ZMPCRM073000.12.01 Users ManualZMPCRM073000.12.01 Users Manual
ZMPCRM073000.12.01 Users Manual
 
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable BatteryPM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
 
E 043 opt shr user manual
E 043 opt shr user manualE 043 opt shr user manual
E 043 opt shr user manual
 
E 070 lipo laser slimming machine
E 070 lipo laser slimming machineE 070 lipo laser slimming machine
E 070 lipo laser slimming machine
 
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
 
ZMPCCM111000.03
ZMPCCM111000.03 ZMPCCM111000.03
ZMPCCM111000.03
 
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable batteryPm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
 

Similar to Máy Điện Di CRYO STAMP

Mh7 eu um v.02
Mh7 eu um v.02Mh7 eu um v.02
Mh7 eu um v.02
Domotica daVinci
 
Zmpcrm073000.12.01 User's Manual
Zmpcrm073000.12.01 User's  ManualZmpcrm073000.12.01 User's  Manual
Zmpcrm073000.12.01 User's ManualPainezee Specialist
 
Aeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualAeotec Multisensor 7 Manual
Aeotec Multisensor 7 Manual
Domotica daVinci
 
Hướng dẫn sử dụng Testo 535
Hướng dẫn sử dụng Testo 535Hướng dẫn sử dụng Testo 535
Hướng dẫn sử dụng Testo 535
Tenmars Việt Nam
 
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Tenmars Việt Nam
 
Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511
Tenmars Việt Nam
 
Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93
Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93
Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93
Tenmars Việt Nam
 
Mh8 fc um
Mh8 fc umMh8 fc um
Mh8 fc um
Domotica daVinci
 
ZMPCZM022000.12.01 User's manual
ZMPCZM022000.12.01 User's  manualZMPCZM022000.12.01 User's  manual
ZMPCZM022000.12.01 User's manualPainezee Specialist
 
Zmpczm022000.12.01 User's manual
Zmpczm022000.12.01 User's  manualZmpczm022000.12.01 User's  manual
Zmpczm022000.12.01 User's manualPainezee Specialist
 
Manual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizadoManual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizado
JorgeCobo11
 
Temperature sensor with binary sensor input start guide
Temperature sensor with binary sensor input start guideTemperature sensor with binary sensor input start guide
Temperature sensor with binary sensor input start guideDomotica daVinci
 
ZMPCZM022000.12.01 User's manual
ZMPCZM022000.12.01 User's  manualZMPCZM022000.12.01 User's  manual
ZMPCZM022000.12.01 User's manualPainezee Specialist
 
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
Domotica daVinci
 
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Tenmars Việt Nam
 
how to use Mst1000 motor ingiting signal
how to use Mst1000 motor ingiting signalhow to use Mst1000 motor ingiting signal
how to use Mst1000 motor ingiting signal
Enzo C
 
Termometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manualTermometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manual
Alberto Angel Villa
 
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIASV5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
MiNeyi1
 
Hi8us hg01 v2 manual
Hi8us hg01 v2 manualHi8us hg01 v2 manual
Hi8us hg01 v2 manual
Nome Sobrenome
 

Similar to Máy Điện Di CRYO STAMP (20)

Mh7 eu um v.02
Mh7 eu um v.02Mh7 eu um v.02
Mh7 eu um v.02
 
Zmpcrm073000.12.01 User's Manual
Zmpcrm073000.12.01 User's  ManualZmpcrm073000.12.01 User's  Manual
Zmpcrm073000.12.01 User's Manual
 
Aeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualAeotec Multisensor 7 Manual
Aeotec Multisensor 7 Manual
 
Hướng dẫn sử dụng Testo 535
Hướng dẫn sử dụng Testo 535Hướng dẫn sử dụng Testo 535
Hướng dẫn sử dụng Testo 535
 
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
 
Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511
 
Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93
Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93
Hướng dẫn sử dụng máy đo bức xạ và cường độ sóng vô tuyến RF Tenmars TM-93
 
Mh8 fc um
Mh8 fc umMh8 fc um
Mh8 fc um
 
ZMPCZM022000.12.01 User's manual
ZMPCZM022000.12.01 User's  manualZMPCZM022000.12.01 User's  manual
ZMPCZM022000.12.01 User's manual
 
Zmpczm022000.12.01 User's manual
Zmpczm022000.12.01 User's  manualZmpczm022000.12.01 User's  manual
Zmpczm022000.12.01 User's manual
 
Manual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizadoManual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizado
 
Temperature sensor with binary sensor input start guide
Temperature sensor with binary sensor input start guideTemperature sensor with binary sensor input start guide
Temperature sensor with binary sensor input start guide
 
ZMPCZM022000.12.01 User's manual
ZMPCZM022000.12.01 User's  manualZMPCZM022000.12.01 User's  manual
ZMPCZM022000.12.01 User's manual
 
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
 
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
 
how to use Mst1000 motor ingiting signal
how to use Mst1000 motor ingiting signalhow to use Mst1000 motor ingiting signal
how to use Mst1000 motor ingiting signal
 
El epm01 en
El epm01 enEl epm01 en
El epm01 en
 
Termometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manualTermometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manual
 
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIASV5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
 
Hi8us hg01 v2 manual
Hi8us hg01 v2 manualHi8us hg01 v2 manual
Hi8us hg01 v2 manual
 

Recently uploaded

The Future of Platform Engineering
The Future of Platform EngineeringThe Future of Platform Engineering
The Future of Platform Engineering
Jemma Hussein Allen
 
FIDO Alliance Osaka Seminar: Overview.pdf
FIDO Alliance Osaka Seminar: Overview.pdfFIDO Alliance Osaka Seminar: Overview.pdf
FIDO Alliance Osaka Seminar: Overview.pdf
FIDO Alliance
 
Generating a custom Ruby SDK for your web service or Rails API using Smithy
Generating a custom Ruby SDK for your web service or Rails API using SmithyGenerating a custom Ruby SDK for your web service or Rails API using Smithy
Generating a custom Ruby SDK for your web service or Rails API using Smithy
g2nightmarescribd
 
How world-class product teams are winning in the AI era by CEO and Founder, P...
How world-class product teams are winning in the AI era by CEO and Founder, P...How world-class product teams are winning in the AI era by CEO and Founder, P...
How world-class product teams are winning in the AI era by CEO and Founder, P...
Product School
 
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...
DanBrown980551
 
Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........
Alison B. Lowndes
 
From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...
From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...
From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...
Product School
 
PCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase TeamPCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase Team
ControlCase
 
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
Product School
 
When stars align: studies in data quality, knowledge graphs, and machine lear...
When stars align: studies in data quality, knowledge graphs, and machine lear...When stars align: studies in data quality, knowledge graphs, and machine lear...
When stars align: studies in data quality, knowledge graphs, and machine lear...
Elena Simperl
 
Assuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyesAssuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyes
ThousandEyes
 
DevOps and Testing slides at DASA Connect
DevOps and Testing slides at DASA ConnectDevOps and Testing slides at DASA Connect
DevOps and Testing slides at DASA Connect
Kari Kakkonen
 
To Graph or Not to Graph Knowledge Graph Architectures and LLMs
To Graph or Not to Graph Knowledge Graph Architectures and LLMsTo Graph or Not to Graph Knowledge Graph Architectures and LLMs
To Graph or Not to Graph Knowledge Graph Architectures and LLMs
Paul Groth
 
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024
Tobias Schneck
 
Elevating Tactical DDD Patterns Through Object Calisthenics
Elevating Tactical DDD Patterns Through Object CalisthenicsElevating Tactical DDD Patterns Through Object Calisthenics
Elevating Tactical DDD Patterns Through Object Calisthenics
Dorra BARTAGUIZ
 
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 previewState of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
Prayukth K V
 
JMeter webinar - integration with InfluxDB and Grafana
JMeter webinar - integration with InfluxDB and GrafanaJMeter webinar - integration with InfluxDB and Grafana
JMeter webinar - integration with InfluxDB and Grafana
RTTS
 
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...
James Anderson
 
The Art of the Pitch: WordPress Relationships and Sales
The Art of the Pitch: WordPress Relationships and SalesThe Art of the Pitch: WordPress Relationships and Sales
The Art of the Pitch: WordPress Relationships and Sales
Laura Byrne
 
Knowledge engineering: from people to machines and back
Knowledge engineering: from people to machines and backKnowledge engineering: from people to machines and back
Knowledge engineering: from people to machines and back
Elena Simperl
 

Recently uploaded (20)

The Future of Platform Engineering
The Future of Platform EngineeringThe Future of Platform Engineering
The Future of Platform Engineering
 
FIDO Alliance Osaka Seminar: Overview.pdf
FIDO Alliance Osaka Seminar: Overview.pdfFIDO Alliance Osaka Seminar: Overview.pdf
FIDO Alliance Osaka Seminar: Overview.pdf
 
Generating a custom Ruby SDK for your web service or Rails API using Smithy
Generating a custom Ruby SDK for your web service or Rails API using SmithyGenerating a custom Ruby SDK for your web service or Rails API using Smithy
Generating a custom Ruby SDK for your web service or Rails API using Smithy
 
How world-class product teams are winning in the AI era by CEO and Founder, P...
How world-class product teams are winning in the AI era by CEO and Founder, P...How world-class product teams are winning in the AI era by CEO and Founder, P...
How world-class product teams are winning in the AI era by CEO and Founder, P...
 
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...
 
Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........
 
From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...
From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...
From Siloed Products to Connected Ecosystem: Building a Sustainable and Scala...
 
PCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase TeamPCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase Team
 
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
From Daily Decisions to Bottom Line: Connecting Product Work to Revenue by VP...
 
When stars align: studies in data quality, knowledge graphs, and machine lear...
When stars align: studies in data quality, knowledge graphs, and machine lear...When stars align: studies in data quality, knowledge graphs, and machine lear...
When stars align: studies in data quality, knowledge graphs, and machine lear...
 
Assuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyesAssuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyes
 
DevOps and Testing slides at DASA Connect
DevOps and Testing slides at DASA ConnectDevOps and Testing slides at DASA Connect
DevOps and Testing slides at DASA Connect
 
To Graph or Not to Graph Knowledge Graph Architectures and LLMs
To Graph or Not to Graph Knowledge Graph Architectures and LLMsTo Graph or Not to Graph Knowledge Graph Architectures and LLMs
To Graph or Not to Graph Knowledge Graph Architectures and LLMs
 
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024
 
Elevating Tactical DDD Patterns Through Object Calisthenics
Elevating Tactical DDD Patterns Through Object CalisthenicsElevating Tactical DDD Patterns Through Object Calisthenics
Elevating Tactical DDD Patterns Through Object Calisthenics
 
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 previewState of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
 
JMeter webinar - integration with InfluxDB and Grafana
JMeter webinar - integration with InfluxDB and GrafanaJMeter webinar - integration with InfluxDB and Grafana
JMeter webinar - integration with InfluxDB and Grafana
 
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...
 
The Art of the Pitch: WordPress Relationships and Sales
The Art of the Pitch: WordPress Relationships and SalesThe Art of the Pitch: WordPress Relationships and Sales
The Art of the Pitch: WordPress Relationships and Sales
 
Knowledge engineering: from people to machines and back
Knowledge engineering: from people to machines and backKnowledge engineering: from people to machines and back
Knowledge engineering: from people to machines and back
 

Máy Điện Di CRYO STAMP

  • 1.
  • 2. CryoStamp CryoStamp is based on Cryoelectrophoresis, implemented Combination therapy that potentially useable coupled with CryoTherapy, Hot Therapy, Iontophoresis, Erectric Medium Frequency Therapy and hot/cold electrical stimulation. CryoStamp is builded the final one on research and development for three years, establish a prominent effect as a new idea of medical instrument for pain. It is a patented article and has applied for a international patent. a theory information file : Nature - 2001. 9 / number.413 Well-balanced penetration on the tissue , Inhibition of exothermic reaction , Anti-inflammatory effect , Relax Tight Muscles and analgesia effect , Improve Circulation of local area
  • 3. Stamp LCD Display Detachable Hand Probe Input Touch Key Intensity Control Knob Pad Connection Socket Hand Probe Hanger CryoStamp Rear of the Main Body Ventilation AC Socket Power Switch
  • 4. <Application> This device applies the cooling stimulus and heating stimulus to the skin and is combination beauty equipment aimed for helping manage the cosmetics well by applying the bio-current like micro-current and low voltage stimuli. New Medicare therapy  NO NEEDLE MESO THERAPY  Cryo Stamp Galvanic Needle Therapy  FACE & BODY LIFTING  VITAMIN C CARE  SKIN TONE & TEXTURE  LASER POST CARE 1) Low Tension Polarity Pad : Length 1,400mm 2) Power Cord Length : 3,000mm 3) Dimensions : 390mm×285mm×116mm[W×D×H] 4) Length of Hand Probe : 1,600mm 5) Weight : 5kg
  • 5. 1. Preparations before Use (1) Check if the power switch is OFF and then connect the power cord. (2) Check the cooling/heating catheter electrode of the main unit and main unit for the foreign substances and clean them up, if any. (3) Check if the components are properly connected. * When using a pad, connect to the connecting socket on the side. 2. Switching Power ON (1) Connect the power cord which is on the rear. (AC 100V ~ 220V, 50Hz ~ 60Hz) (2) Press the power switch to switch the power ON. (3) After the buzzer beeps three times, the Display is shown as below. ---> It must be displayed without blinking. * However, if the LED around the Intensity Control Knob in the center blinks, all of the Input Keys ( ∧, F, ∨ ) do not activate and the equipment stops. * In that case, rotate the Intensity Control Knob counterclockwise until it clicks and the blinking will stop. ---> This situation is the function of Auto Zero Start for the safety of the equipment, which is not out of order. Touch-type Input Keys are positioned under the Intensity Control Knob. How to useCryoStamp
  • 6. 3. LCD Display (1) If the power is switched ON, basically the default value will be displayed on the Display. The default value cannot be changed and is displayed whenever the power is switched ON. Temperature -5℃ Time 15 Minute Mode MC Polarity (-) Intensity All level displays are OFF (2) Setting Function Range Temperature -15℃ ~ 20℃ (automatically displayed as 'Cool') 21℃ ~ 29℃ Range that is not used 30℃ ~ 40℃ (automatically displayed as 'Hot') Time 0 ~ 60 min. Mode MC or MF Polarity (-) or (+) Intensity 24-step level display How to useCryoStamp
  • 7. How to use 4. Input Touch Key There are 3 kinds of keys in the Input Touch Key. Slightly touch the key of the mode desired and the value will be input. (1) Setting Temperature Touch to make the letters of 'Temperature' blink. Touch , to adjust the temperature to the desired value. (2) Setting Time Touch to make the letters of 'Time' blink. Touch , to adjust the time to the desired value. (3) Setting Mode Touch to make the letters of 'Mode' blink. If is touched, the mode is set to MC. If is touched, the mode is set to MF. (4) Setting Polarity Touch to make the letters of 'Polarity' blink. If is touched, the mode is set to (-). If is touched m the mode is set to ⊕. (5) Storing the Set Value In order to store the Temperature and Time changed at (1) and (2) above, press and keys simultaneously and then a beep sounds once a second. If they are touched for over 3 seconds and then released, the set value shall be stored and can be used repeatedly afterwards. The value does not change even when the power is OFF. (6) Accessing the Stored Value In order to access the value stored, press and keys simultaneously and then a beep sounds once a second. If they are touched for over 3 seconds and then released, the user can access the stored value and, if touched again, the value will be changed to the default value. The stored and default values are displayed in turn repeatedly every time the keys are pressed. CryoStamp
  • 8. 5. Descriptions of Each Function (1) Temperature The temperature is basically set at -05℃ as the default value which is most normally used, and the user can adjust the temperature before using. If the changed temperature is not stored at this time, the value will be lost after a cosmetic procedure or a treatment. The storing method is explained in the 'Storing in the Set Value.' (2) Time The Time is set in minutes and basically set at 15 minutes as the default value which is mostly normal duration of a procedure and the user can adjust the time before using. If the changed time is not stored at this time, the value will be lost after a cosmetic procedure or a treatment. The storing method is explained in the 'Storing in the Set Value.' (3) Pulse Form Mode There are two pulse form modes of MC and MF. The MC mode applies the micro-current to the human body and helps the ionized solution to be absorbed well into the skin. (max. current: 100uA) The MF mode performs the function to help the ionized solution to be absorbed well into the skin by applying the pulse modulated low-voltage (max. voltage: 5-volt) to the human body. (The intensity becomes stronger as it gets closer toward 100%. As there are differences in the electric irritability according to the human body, a special caution is required to prevent the electric shock.) (4) Polarity There are two polarities of (-) and ⊕. When using (-) polarity, the polarity for the hand probe is (-) and for the pad is ⊕when with the product of which solution is ionized in (-) polarity. (Most of the cosmetics are (-) polarity.) When using ⊕ polarity, the polarity for the hand probe is ⊕ and for the pad is (-) when used with the product of which solution is ionized in ⊕ polarity. Selection of polarity can be used only for the electric stimuli of MC and MF modes and they function only when the pad is connected. That is, the selections of mode and polarity do not work when the pad is disconnected. Function ExplanationCryoStamp
  • 9. 6. Operation (1) Operation by the Preset Value Stored If the power is switched ON, the screen displays the default values. If the Intensity Control Knob is turned on immediately at this time, the equipment does not work. Be sure to touch the F key to change to the stored value and one of the functioning letters shall blink. If the Intensity Control Knob is set to ON position in this status, the equipment starts operating. (2) Operation by the Default Value Before turning on the Intensity Control Knob for the operation by the setting value, follow the Accessing the Stored Value of the above 4-(6) to access the default value and the turn on the Intensity Control Knob to operate the equipment. (3) Operation by the Changed Value To run the equipment only one time by the changed value, set the value in the Input Touch Key of the 4 and the turn on the Intensity Control Knob to operate the equipment. (4) Repeated Operation In order to repeat the above (1), (2) and (3), turn off the Intensity Control Knob after the operation is over and the value shall disappear to be changed to the stored value. 7. Completion of Operation If the preset time is over, the time display shows 00 and the buzzer signalling the end beeps 5 times and all outputs are stopped with the LED around the Intensity Control Knob blinks. If the Lever is turned OFF, the blinking stops. Function ExplanationCryoStamp
  • 10. 8. Warning for Malfunction If the temperature gets too high enough to cause the burn or something hazardous during operation, the equipment stops operating to prevent the safety accidents, the buzzer beeps and the LED around the Intensity Control Knob keeps blinking. At this time, turn off the Intensity Control Knob and, after stopping the equipment about for 10 minutes for its stabilization, re-operate the equipment. (if the problems continue afterwards, call for a qualified engineer for the safety check.) 9. Cautions for Operation ① Customers should not be connected, in any case, to the grounded part that the current might flow. ② Do not use this equipment for the customer who is wearing a pacemaker. ③ Do not use this equipment for a cancer patient or a patient with a similar disease. ④ The equipment should be used only by the person who received the specialized training. ⑤ Be careful of the followings in process of operating the equipment. - Check if anything abnormal with the customer or the equipment is found during operation. - If anything wrong with the customer or the equipment is found, stop operating the equipment and check the customer's safety. Re-start operating the equipment only when there is no disorder after checking up the status of the customer and the equipment. Function ExplanationCryoStamp
  • 11. Protection type and level for electric shock : Class ll Equipment Input voltage : 110~ 220VAC/50~60Hz Output voltage(device power) : 100W Frequency : 10KHZ±10%,Sine wave / DC Output voltage : 42V p-p / 1V p-p Electrification method : Gap electrification Timer : 1~60minutes , set a standard point by 1minute unit Safety Device : Zero Start Temperature : -10˚C~45˚C Specifications Combination Therapy System CryoStamp