SlideShare a Scribd company logo
Hi8us
Operating Instructions
for Infrared Thermometer
Model: HG01
Version: V2
Non-sterile
Reserve forstandby application
CONTENTS
ear user: Thank you for purchasing the Infrared Thermometer of our
company.
he device is only to be used, maintained and serviced by personne
tamiliar with the operating manual as well as the 'Important Safety
ntormation'. The instruction should be reserved for standby application.
01. Important Safety Information
02. Product Benefits
03. Description Of Symbols
04. Intended Use
05. Features
06. Product Description
07. Technical Specifications
08. Use
09. Errors
10. Batteries Replacement
11. Cleaning and Maintenance
12. Electromagnetic Compatibility
13. Troubleshooting
14. Temperature Knowledge
15. After-Sale Service
16. Accessory
(1)
1. Important Safety Information
1) This device must only be used for the purposes described in this
operating instruction. The device is intended for professional or family use
only.
2Thethermometer is not waterproof. Do not immense the device in water
orinother liquids. Follow the instructions in Cleaning and Maintenance if
needed.
3 Keep the themometer away from direct sunlight. Keep the thermometer
in clean, dry environment (5~45°C, humidity <85%)
4) Do not touch the sensor inside the device.
5) It may affect the accuracy of measurements when one's forehead is
cOvered by hair, perspiration, cap or scari.
6) Do not drop, dissemble, repair or transform the device.
7) Do not use the device near large electromagnetic fields for the accuracy
of
measurements maybe affected.
8) Should problem occur with your device, please contact your retailer. Do
not attempt to repair the device by yourself.
9) If batteries or components are swallowed accidently, please comply with
local laws and regulations.
10) Do not open the battery cover when testing in avoidance of electric
shock.
11) The device should be used in stable temperature. If there exist sudden
change in environment temperature, please notice if the sensor is covered
by moist. Clean the moist as described in Cleaning and Maintenance
before the next operation in order to get an accurate result.
12) When the device is out of service for long period, the batteries should
be taken out in prevention of leakage.
13) Do not load the device with used and new batteries. Damage to the
device may occur due to differences in discharge characteristics.
Warning:
Keep the deviceawayfrom children.
Do not throw the device or batteries into fire
Use ofthis thermometer is not intended as a substitute for consultation
with your physician.
(2)
2. Product Benefits
Convenient and fast: measurements error up to t0.2°C, measuring
time0.5-2s;
Width ofmeasurements: 0.0-100°C;
Various applications:
1) Human body temperature measurements;
2) Objects temperature measurements (eg. Rice paste temperature);
3) Liquids temperature measurements (eg. Bath water for babies, milk);
Clean and hygienic: Non-contact measurements, measures distance
1-3cm, preventing cross-infection;
Simple and practical: measures at one-press; mode switch at
one-press; memorization query at one-press, simple for operation;
Measurement Warning: measured temperature> 37.5°C the devicee
alam song.
Multiple memorizations: memorization of up to 32 measurements,
easy for comparison
Fix setting: parameters adjustable forsuiting different races or
human bodies.
3. Description Of Symbols
LOT batch number SN ProductSerial Number
M
Manufacturer Manufacturing date
Caution: please refer to the manual Expiatory date
Non-ionizing radiation signal Type-B application part
(3)
4.Intended Use
Human body temperature measurements:
Objects temperature measurements (eg. Rice paste temperature)
Liquids temperature measurements (eg. Bath water for babies, milk)
5.Features
This thermometer is classified as type-B, inner electric power in
terms of prevention degree of electric shock;
This themometer is classified by its safety degree as follows: It
can't be operated in an environment that contains flammable
anesthetic gas, air, oxygen and Nitrous oxide;
This thermometeris classified as No-Special-Protection according
to GB4208 regulations;
This thermometer is classified as Continuous operation equipment
according to operating mode;
Lists of accessories:
Operating Instructions x 1; Certification x 1.
6.Product Description
Product Composition =
2
1) Passive IR Sensor
2) LCD Display
3) Multifunction button group
4) ON/Scan Button
5) Battery Cover
5
(4)
Product Description
LCD Display Description
1) Surface Mode symbol
2) Body Mode symbol
3) Digital Layout
4) Measurements Layout
5) Battery Low Symbol
6) Volume On/Off Symbol
7) TemperatureC (Celsius)/°F(Fahrenheit) Scale
8) Memorized Measurements Serial Number
9) Memorization State Reminder
8
Objecttemperature Temperature
88
2Memory
8888
4 5
(5)
7. Technical Specifications
Operating temperature: 16-35°C
Humidity rate: s85%
Power: DC 3V (2xAAbatteries)
Size: 138 x 95 x 40 mm (Lx W x H)
Weight: 90g
Measuring range: In BodyMode: 32-42.9°C
Accuracy:
a) 32.0-34.9C: +0.3°C
b)35.0-42.0°C: t0.2°C
c)42.1-42.9°C: +0.3°C
Measuring distance: 3-5cm
Measuring time: 0.5-2s
Temperature Mode:
a) 32.0-37.4°C Normal
b) >37.5C Alarm
Automatic Stop: «=18s
Storage Temperature and Humidity: -20°C-55°C; s93%
If necessary, circuit diagram and list of components could be
provided for repairing use for technical personnel.
(6)
8. Use
.BatteriesInstallation
Press down and then backward at battery cover open, install
3.0VDC (wo AAA alkaline batteries), close the battery cover.
Please notice the positive and negative poles on the batteries.
Do not reverse the poles.
Ready for Measurements
Correct operation leads to accurate measurements, or else
measurements erors may occur. In avoiding inaccuracies of the
results, follow the instructions below:
1) Aim towards the center of one's forehead from a distance of
1-3cm and keeps vertical, then press the measuring key. The
temperature is displayed on the indicator immediately;
2) Before measurements, please make sure there is no hair,
perspiration, makeups or hat covered on the forehead;
3) Keep the device in the measuring environment for more
than 5 minutes. Measures after the device's temperature
becomes accordance with the measuring environment;
4) Cold compression and other cooling measures taken by the
tested person may lead to lowered measurementsresults
Measurements should avoid to be taken under such
circumstances;
5) Measurements should be taken in stable temperature
environment. Do not operate the device near to fan, air
conditioner outlet where the airflow is strong;
6) Under the changing environment, the thermometer should
be stable for 20 minutes before use.
7) The test object is suitable for all people, forehead or wrist,
and the dlinical deviation is +0.2 C.
(7)
Use
8) If the device is not used for a long time, it should be place in
the new operating environment for 30 minutes before
measurements;
9) Do not operate the device in strong sunlight;
10) It's suggested that the most displayed result be taken for
every 3 measurements;
11) To measure human body temperature, select 'Body
temperature Mode'; To measure other objects, liquids and food
temperature, select 'Object Temperature Mode;
12) If there are irresistible reasons that cause lowered
temperature of forehead. You can take the temperature behind
the earlobe;
Starting toMeasure
1) Aim towards the forehead,
press power button. LCD
instructor would display all the
numbers and symbols. The
device will test the room
temperature and will delay turning
on for one or two seconds;
2) One 'beep' sound or three
'beep' sounds would be heard
once the display is over,
indicating the end of power-on
measurements process. LCD
would demonstrate the measured
Odeer
88
Memory
8888
C
Memory
368
target's temperature. At the same
time, the backlight would flash
one colors from green, yellow and
red according to the setting;
(8)
Caution:
When the temperature of high fever is set above the LCD display
crying face, accompanied by 3 beep, beep, beep alarm sound.
This is to warn the patient his/her possibility of having a fever.
To ensure the accuracy of the measurement, please wait at least
30 seconds after 5 consecutive measurements.
Shifting the Measuring Mode
1) When the power is on, press the 'Mode' button to select
between 'Body temperature Mode' and 'Object Temperature
Mode'. Measurements range of 'Object Temperature Mode'
ranges at 0-100°C
2) Body Temperature Mode' is used to measure temperature
of inner human body. Object Temperature' is used to measure
temperature of surface of objects. (preset: Body Temperature
Mode)
(9)
Memorization query
In the on state, pressing the Memo' button allows user to enter
memorization mode. To query on previous memorized values,
press shortly on 'Memo' button.
Note: 1) larger serial number identifies earlier values, vise versa.
2) Memorized values directly display if there exist values
that have been memorized.If not," would be displayed as
diagram in the right demonstrated.
Tenperaure C
32
Memory
3) The device is capable for storing 32 groups of measurements
values. The other ones would be covered automatically according to
time sequence.
(10)
1) Units Setting F1 (presets as Celsius)
in the on state, long press the multi-function key (MODE) to
enter F1, let go of F1 parameter, press the MEMO key or SET
key (SET) to switch the units of Celsius and Fahrenheit, then
press the multi-function key (MODE) to confirm the unit setting.
and enter F2 at the same time.
2) In the F2 state, press SET to tum on the prompt sound,
press MEMO to turn off the prompt sound, then press MODE to
confim the setting and enter F3.
3) F3 is SET for highfever waming (factory setting is 38.1C).
When entering F3 state, press the MEMO key to reduce 0.1C,
press the SET key to add 0.1 C, then press the MODE to confim
the alarm point setting, and enter F4 at the same time.
4) press SETto turn on the screenlight in the state of F4,
press MEMO to turn off the screen light, and then press MODE
to return to the test state.
(11)
9. Errors
LCD/problems meaning possible cause and solutions
The value is above the
measurements range selected, either
superior to 42.9°C in Body mode or
superior to 100°C in Object mode.
Measured
temperature
over-high
The value is below the
measurements range selected, either
minor to 32°C in Body mode or minor
to 100°C in Object mode.
Measured
Lo
temperature
over-low
Measured The device is not in operation
Err temperature out of temperature. (<16°C or >35°C)
range
Error function alert After the system self-checked and
8888 error occurs, the screen flashes and
automatically stops
The battery power is low. The screen
will turn off after the Lo" flashes.
Please replace the battery
immediately.
BatteryIowalert
ELO
The environment temperature is
unstable. Please place the device in
stable environment for 30 minutes or
more.
Please make sure the battery is
properly installed. Pay attention to the
positive and negative poles of the
batteries. Confirm whether the battery
is still usable.
Environment
POS temperature
unstable
Blank screen
(12)
10. Batteries Replacement
The device uses 3.0VDC (two AAA alkaline batteries). When the
device shows that the battery is low, please refer to Battery
Installation chapter to change the batteries.
Cautions:
1) When opening the battery cover, pay special attention to the poles
of the batteries. Wrong poles could lead to damage to the device
2) After long period out of service, please take out the batteries in
prevention of leakage.
3) When the battery leaks or molds, please do not use the batteries.
4) Do not take the batteries close to or throw them into fire in
prevention of explosion
5) Do not store batteries in overheat or humid environment.
6) In prevention of short circuit, do not place batteries, coins, keys
and other metal materials together in a pocket or in containers that
could lead to short circuit problem.
11. Cleaning and Maintenance
The infrared sensor is the most intricate partofthe device. Do not
touch the sensor with fingers or other materials. Sensor should be
under careful protection, or else the accuracy of measurements will
be affected.
Clean the device with a cotton bud lightly moistened with 70%-75%
alcohol. Do not let the liquid enter inner body of the device. Do not
clean the device with corrosive detergent. Do not immense the device
with water or other liquids.
(13)
12. Electromagnetic Compatibility
Protects the surface of LCD carefully.
Place the device in a dry environment, and keep it awayfrom dust,
pollution and direct sunlight.
Cleaning every half a year or less is suggested.
Cautions:
1) User should install and operate the thermometer according to
the Electromagnetic Compatibility information in the files
attached to the device.
2) Portable product and RF communication equipment may
affect the performance of the device. Avoid the disturbance of
strong electromagnetic equipment, like mobile phones,
microwaves.
3) For more information, please refer to Chapter 16.
Cautions:
Waming:
The device should not operate next to or piled up with other
equipment. If necessary, observation should be conducted in
making sure it operates properly.
Use of accessories and cables other than manufacturer-provided
applications may cause extra radiation of infrared ray or lower
capability of disturbance resistance.
(14)
13. Troubleshooting
Question 1: Why does the screen display 'Lo' in the same
environment?
Answer: Possibilities:
1) The measurements distance is too far. The device may have
measured the temperature of the environment. The thermometer is
designed to measure temperature within a distance of 1-3cm. The
best distance is around 1cm.
2) The measurements position is improper. The thermometer should
be aimed at the center of one's forehead and should be vertical
3) The measured person may have hair, perspiration, water over his
forehead. The person may have been cooling compressed,
Antipyretics prescribed, blown by cold wind. The measurements
should be retaken after the measured person stay in a stable
environment for 5-10 minutes.
Very few people have lower forehead temperature than others
when they were born. In this occasion, the results may remain to be
Lo'. The user could select 'In Surface Mode' to measure the target
as well as other people's forehead surface temperature. The
comparison could be made under contrast.
4) overall temperature error.
Question 2: Feels like the result is inaccurate when first use. Why?
Answer: Advice for the 1st use are listed as follows:
(15)
Troubleshooting
1) Place the thermometer in a stable environment for more than
30 minutes;
2) Take the temperature of a person using a conventional
thermometer, getting a 36.8°C result for instance;
3) Take the temperature of the same person using the
non-contact infrared thermometer. Keep the 1-3 cm distance
between the thermometer and the forehead, take care to remove
any obstacle which could alter the measurements (hair,
perspiration...). If the similar result is got, the non-contact
infrared thermometer is properly. set and ready for use.
Question 3: Is there any harm to human body using the infrared
thermometer? Is there any radiation?
Answer: Infrared thermometer is used to measure human body
temperature by collecting infrared radiation of human body. It
passively receives infrared radiation energy. It does not need to
contact human body directly and does not bring cross infection
of different human bodies. The thermometer has no radiation to
human body, so it has no harm to human body.
Question 4: The thermometer shows temperature over-high and
over-low to all tested people, is it a product quality problem?
Answer: This kind of problem is generally caused by the setting
of the thermometer. It can be corrected according to user's
instructions.
(16)
14. Temperature Knowledge
The human body is a complex biological comprehensive system.
Body temperature is an important feature of human body and life.
Usually, we check the temperature of forehead, cochlea, anus, oral
cavity and underarms to evaluate our health condition. Different
body parts own different regular temperature.
Normal Normal
Tested body part| temperature
Age temperature
Cochlea
35.8-38C 0-2 years old 36.4-38 C
temperature
Forehead 34.7-37.8C 3-10 years old 36.1-37.8°C
temperature
Oral
35.5-37.5°C 11-65 years old 35.9-37.6°C
temperature
Underarm
34.7-37.3°C >65 years old 35.8-37.5°C
temperature
Anus
36.6-38 C
temperature
Human body temperature changes with time within a day and is also
affected by other external conditions such as age, gender, skin
color, skin thickness and age. Specifications are listed in the table.
There exist difference between female body temperature and male
body temperature. Generally speaking, men are about 0.3C higher.
Female body temperature during ovulation will rise 0.3 C to 0.5 C
than usual. Therefore, we can use this to know whether a woman is
in the ovulation period to facilitate heredity or contraception.
(17)
Temperature Knowledge
The usual method is to use a thermometer to measure the basal
body temperature of a female individual every day, and then
convert it into a basal body temperature change curve chart,
which can clearly see the ovulation period.
15. After-Sale Service
This product enjoys a one-year free warranty with a shopping
invoice from the date of purchase.
Package and Operating Instructions are not covered by the
warranty.
We target the following damage caused bythe user, please
forgive us for failing to provide Free warranty service for the
following conditions:
1) Failure caused by unauthorized refitting and refitting of
products.
2) Failure in the course of use or handling or inadvertent drop
3) Failure caused by disobedient operation towards the
instructions
4) Failure caused by lack of reasonable maintenance
Warranty outside the range of the repair services would be
charged according to the corresponding provisions.
In request forwarranty service, please take the device to the
dealers' point.
(18)
16. Accessory
Announcement of Guiders and Manufacturers
This infrared thermometer is intended for use in the
electromagnetic environment specified below. Purchaser or user of
this infrared thermometer should ensure that it is operated in such
electromagnetic environment.
Emission experiment Compliance Electromagnetic Environment-Guidance
The thermometer is only used for its
internal functions, so its radio
Group 1 frequency emissions are low. The
possibility ofinterference to nearby
electronic equipment is very low.
Radio frequency
emission GB4824
The infrared thermometer is suitable|
to use in all equipment, including
domestic installations and
Radio frequency
emission GB4824
Harmonic emissionInadequatelinstallations directly connected to
GB17625.1
VoltageFluctuation/
Flashover Emission Inadequate|
GB17625.2
Type B
residential and public low-voltage
power grids.
(19)
Accessory
Announcement ofguiders and manufacturer- Electromagnetic immunity
Thisinfrared thermometer is intended for use in the current environment
specified below. Purchaser or user of this infrared thermometer should
ensure it's operated in such current environment.
Ec60601
Experimental level
Immunityy
Experiment
Electrostatic t6KV Contact
discharge
GB/T17526.2 8KV Air
Compliance Electromagnetic
Environment Guidance
The floor should be
wood, concrete or tile. If |
discharge thefloor is covered with
synthetic material, the
discharge relative humidity shall be
Jat least 30%
level
t6KV
Contact
discharge
discharge 8KV Air
Electrical
|transient
pulse group
GB/T 17626.4
Surg
GB/T 7626.11 2KV To Ground
Voltage sag,
transient
interruption and| 40%UT, Lasts for 5circles
voltage change (on UT, >60% sag)
of input cable
GB/T 17626.5 circles (on UT, >30%sag)
:2KV Powercable
1KV Output
input cable Inadequate Inadequate
1KV ToGround
Inadequate Inadequate
<5%UT,Lastsfor0.5
circles (on UT, >95%sag)
70%UT, Lasts for 25 Inadequate Inadequate
<5%UT,Lastsfor 5s (on
UT, >95%sag)
Power
requencyy
electric field
(50-60Hz) GB/T
17626.8
The power frequency
magnetic field should own
3A/m 50/60Hz|the characteristic of power
requency magneticfield in
typical commercial or
hospital environment.
Note: Ur refers to AC network voltage before test voltage application.
3A/m
(20)
Accessory
Announcementof Guiders and Manufacturer - Electromagnetic Immunity
This infrared thermometer is intended for use in the Electro alkali environment
specifed below. Purchaseror user of this infrared thermometer should ensure it's
operated in such Electroalkalienvironment.
Experimenton IEC60601
Electromagnetic Experimental level
immunity
RF conduction 3V (valid)
(GB/T 17626.6) 150KHz-80M for
I radiation
(GB/T 17626.3) |3V/M
ComplianceElectromagnetic
Environment Guidance
level
Inadequate |Portable and mobile RF communication
equipment should not be used closer to
any part of this infrared thermometerthan
the recommended isolation point,including
cables. The distance shall be calculatedby|
the formula corresponding to the
Hz 3VIM
80MHz-2.5G
Hz
Note1: At 80MHz and 800 MHz, theformularansmtterfrequency
of higher frequency band is adopted.
Note2: These guidelines may not apply to
all situations. Electromagnetic propagation D1.2VP 80MHz-800MHz
is affected by the absorption and refiectionD=2.3VP 80OMHz-2.5GHz
of buildings, objects and human body.
Recommended separation distance
D=1.2 P
Formula:
P-Accords to the maximum rated output
A Fixed generator,for example:base stationspower of transmitter provided on the
of wireless (cellularlcordless) telephones and transmitter license (W)
ground mobile radios, amateurradios, AM and D-Recommended separation distance (m)
FM radio broadcasts, and television broadcasts, The field strength of the fixed RF
the field strength cannot be predicted accurately. |transmitter is determined by the
In order to evaluate the electromagnetic
environment offixed RF transmitter, observation Irange, Dshould be lower than the
of real electromagneticfield should be considered. [compliancelevel.
f the feld strength of the infrared thermometer is higher thantheapplicableRFcompliance
level, thedevice should be observed and verified.Ifabnormal perfomance is observed,
additional measure is necessary to be taken. For example, to adjust the direction or
position of the infrared thermometer.
The wholefrequencyrangeshould be around 150KHz-80MHz, while the field strength
should be lowerthan 3V/m.
electromagnetic survey. In each frequency
(21)
Accessory
Recommended Isolation Distance Between the Portable and Mobile
Communication Equipment and the Infrared Thermometer
The infrared thermometer isexpectedtobeusedin the electromagnetic environment
controlled by radio frequency radiation disturbance. According to the maximum rated
output power of the communication equipment, the buyer or user can
maintain the
variable and mobile radio frequency through the following recommendations
lsolation distance corresponding to different
frequencies of transmitter (m)
Maximum rated
output power of
transmitter (W) 150 KHZ-80MHZd
=12P
80 KHZ-80OMHZ d 80KHZ-2.5GhZ d
12NP 12VP
0.01 Inadequate 0.12 0.23
0.1 Inadequate 0.38 0.73
1 Inadequate 1.2 2.3
10 Inadequate 3.8 7.3
100 Inadequate 12 23
For transmitters not listed in the above table, d refers to the recommended
isolation distance of rated maximum output power(m), which can be determined
by the formula in the corresponding transmitter frequency column. P refers to the
transmitters maximum output rating(W) provided by the transmitter
manufacturer
Note1: Formula of higher frequency range on 8OMHZ and 80OMHz frequencies
should be applied
Note2: These guidelines may not be suitable for all situations. Electromagnetic
propagation is affected by absorption and reflection of buildings, objects and
human body.
(22)
Filing Certificate number (Emergency codel Technical requirement code):
medical device manufacturer license number: 20200041
Medical Device registration number: 20202070605
Model Number: HGO01
Version: Vv2
Manufacturer:Hunan Honggao Electronic Technology Co.,td
Addres: Block 5, Comprehensive Industrial Park, Tenghui
Pioneer Park, Nanxian Economic Development Zone,
Yiyang, Hunan Province
Tel:0769-83562008

More Related Content

What's hot

Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3
Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3
Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3
Tenmars Việt Nam
 
Hướng dẫn sử dụng testo 435-3
Hướng dẫn sử dụng  testo 435-3 Hướng dẫn sử dụng  testo 435-3
Hướng dẫn sử dụng testo 435-3
Tenmars Việt Nam
 
E 043 opt shr user manual
E 043 opt shr user manualE 043 opt shr user manual
E 043 opt shr user manual
E-beauty
 
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
en.ofweek.com Industrial B2B Marketplace
 
Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480
Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480
Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480
Tenmars Việt Nam
 
Hướng dẫn sử dụngTesto 310
Hướng dẫn sử dụngTesto 310Hướng dẫn sử dụngTesto 310
Hướng dẫn sử dụngTesto 310
Tenmars Việt Nam
 
Hướng dẫn sử dụng Testo 480
Hướng dẫn sử dụng Testo 480Hướng dẫn sử dụng Testo 480
Hướng dẫn sử dụng Testo 480
Tenmars Việt Nam
 
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Tenmars Việt Nam
 
Autel MaxiLink ML329A User Manual
Autel MaxiLink ML329A User ManualAutel MaxiLink ML329A User Manual
Autel MaxiLink ML329A User Manual
Tim Miller
 
Autel Powerscan PS100 User Manual
Autel Powerscan PS100 User ManualAutel Powerscan PS100 User Manual
Autel Powerscan PS100 User Manual
obddeal
 
Testo 112 datasheet 2012
Testo 112 datasheet 2012Testo 112 datasheet 2012
Testo 112 datasheet 2012
Testo Limited
 
Testo 720 datasheet 2012
Testo 720 datasheet 2012Testo 720 datasheet 2012
Testo 720 datasheet 2012
Testo Limited
 
Hướng dẫn sử dụng Testo 310
Hướng dẫn sử dụng Testo 310Hướng dẫn sử dụng Testo 310
Hướng dẫn sử dụng Testo 310
Tenmars Việt Nam
 

What's hot (13)

Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3
Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3
Hướng dẫn sử dụng máy đo nhiệt độ bề mặt Testo 435-3
 
Hướng dẫn sử dụng testo 435-3
Hướng dẫn sử dụng  testo 435-3 Hướng dẫn sử dụng  testo 435-3
Hướng dẫn sử dụng testo 435-3
 
E 043 opt shr user manual
E 043 opt shr user manualE 043 opt shr user manual
E 043 opt shr user manual
 
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
 
Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480
Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480
Hướng dẫn sử dụng nhiệt ẩm kế tự ghi Testo 480
 
Hướng dẫn sử dụngTesto 310
Hướng dẫn sử dụngTesto 310Hướng dẫn sử dụngTesto 310
Hướng dẫn sử dụngTesto 310
 
Hướng dẫn sử dụng Testo 480
Hướng dẫn sử dụng Testo 480Hướng dẫn sử dụng Testo 480
Hướng dẫn sử dụng Testo 480
 
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
Hướng dẫn sử dụng máy đo hiệu chuẩn đa năng Extech 412400
 
Autel MaxiLink ML329A User Manual
Autel MaxiLink ML329A User ManualAutel MaxiLink ML329A User Manual
Autel MaxiLink ML329A User Manual
 
Autel Powerscan PS100 User Manual
Autel Powerscan PS100 User ManualAutel Powerscan PS100 User Manual
Autel Powerscan PS100 User Manual
 
Testo 112 datasheet 2012
Testo 112 datasheet 2012Testo 112 datasheet 2012
Testo 112 datasheet 2012
 
Testo 720 datasheet 2012
Testo 720 datasheet 2012Testo 720 datasheet 2012
Testo 720 datasheet 2012
 
Hướng dẫn sử dụng Testo 310
Hướng dẫn sử dụng Testo 310Hướng dẫn sử dụng Testo 310
Hướng dẫn sử dụng Testo 310
 

Similar to Hi8us hg01 v2 manual

Medical Infrared Thermometer - K1176079898
Medical Infrared Thermometer - K1176079898Medical Infrared Thermometer - K1176079898
Medical Infrared Thermometer - K1176079898
Nome Sobrenome
 
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Tenmars Việt Nam
 
HEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 ManualHEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 Manual
Domotica daVinci
 
Thermometer.pptx
Thermometer.pptxThermometer.pptx
Thermometer.pptx
VaishnaviSalunkhe15
 
2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...
2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...
2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...
Gurin Products, LLC
 
Termometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manualTermometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manual
Alberto Angel Villa
 
Mh7 eu um v.02
Mh7 eu um v.02Mh7 eu um v.02
Mh7 eu um v.02
Domotica daVinci
 
AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...
AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...
AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...
AshwiniS72
 
Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511
Tenmars Việt Nam
 
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
Tenmars Việt Nam
 
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
Shandong iSentrol Electronic Technology Co., Ltd
 
Md812 new-version
Md812 new-versionMd812 new-version
Md812 new-version
alice zolo
 
HVAC 2 التدفئة والتهوية و تكييف الهواء
HVAC  2  التدفئة والتهوية و تكييف الهواءHVAC  2  التدفئة والتهوية و تكييف الهواء
HVAC 2 التدفئة والتهوية و تكييف الهواء
maymohamed29
 
الهندسيه الميكانيكيه الشامله hvac 1
الهندسيه   الميكانيكيه  الشامله  hvac  1الهندسيه   الميكانيكيه  الشامله  hvac  1
الهندسيه الميكانيكيه الشامله hvac 1
maymohamed29
 
الهندسيه الميكانيكيه الشامله hvac 1
الهندسيه   الميكانيكيه  الشامله  hvac  1الهندسيه   الميكانيكيه  الشامله  hvac  1
الهندسيه الميكانيكيه الشامله hvac 1
maymohamed29
 
E 8-personal
E 8-personalE 8-personal
E 8-personal
medoo2002
 
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
Shandong iSentrol Electronic Technology Co., Ltd
 
Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123
Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123
Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123
Tenmars Việt Nam
 
Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2
Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2
Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2
Tenmars Việt Nam
 
Hướng dẫn sử dụng Testo 435-3
Hướng dẫn sử dụng Testo 435-3Hướng dẫn sử dụng Testo 435-3
Hướng dẫn sử dụng Testo 435-3
Tenmars Việt Nam
 

Similar to Hi8us hg01 v2 manual (20)

Medical Infrared Thermometer - K1176079898
Medical Infrared Thermometer - K1176079898Medical Infrared Thermometer - K1176079898
Medical Infrared Thermometer - K1176079898
 
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
Hướng dẫn sử dụng máy đo nhiệt độ Testo 610
 
HEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 ManualHEL-ZW-THERM-FL2 Manual
HEL-ZW-THERM-FL2 Manual
 
Thermometer.pptx
Thermometer.pptxThermometer.pptx
Thermometer.pptx
 
2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...
2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...
2-in-1 Professional Clinical RY210 Large LCD Non-contact Infrared Thermometer...
 
Termometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manualTermometro IR con guia laser 320 manual
Termometro IR con guia laser 320 manual
 
Mh7 eu um v.02
Mh7 eu um v.02Mh7 eu um v.02
Mh7 eu um v.02
 
AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...
AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...
AI Fever Screening System TTA-AI Series- Designed to Capture & Recognise Huma...
 
Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511Hướng dẫn sử dụng Testo 511
Hướng dẫn sử dụng Testo 511
 
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
 
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
 
Md812 new-version
Md812 new-versionMd812 new-version
Md812 new-version
 
HVAC 2 التدفئة والتهوية و تكييف الهواء
HVAC  2  التدفئة والتهوية و تكييف الهواءHVAC  2  التدفئة والتهوية و تكييف الهواء
HVAC 2 التدفئة والتهوية و تكييف الهواء
 
الهندسيه الميكانيكيه الشامله hvac 1
الهندسيه   الميكانيكيه  الشامله  hvac  1الهندسيه   الميكانيكيه  الشامله  hvac  1
الهندسيه الميكانيكيه الشامله hvac 1
 
الهندسيه الميكانيكيه الشامله hvac 1
الهندسيه   الميكانيكيه  الشامله  hvac  1الهندسيه   الميكانيكيه  الشامله  hvac  1
الهندسيه الميكانيكيه الشامله hvac 1
 
E 8-personal
E 8-personalE 8-personal
E 8-personal
 
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
 
Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123
Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123
Hướng dẫn sử dụng máy đo tốc độ gió, nhiệt độ Extech 407123
 
Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2
Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2
Huong dan su dung nhiet ke hong ngoai testo 830 T1, T2
 
Hướng dẫn sử dụng Testo 435-3
Hướng dẫn sử dụng Testo 435-3Hướng dẫn sử dụng Testo 435-3
Hướng dẫn sử dụng Testo 435-3
 

More from Nome Sobrenome

Manual Karcher K3390 K 3390 - lista de peças de reposição part number
Manual Karcher K3390 K 3390 - lista de peças de reposição part numberManual Karcher K3390 K 3390 - lista de peças de reposição part number
Manual Karcher K3390 K 3390 - lista de peças de reposição part number
Nome Sobrenome
 
Quansheng TG UV2 TGUV2 - complete user manual
Quansheng TG UV2 TGUV2 - complete user manualQuansheng TG UV2 TGUV2 - complete user manual
Quansheng TG UV2 TGUV2 - complete user manual
Nome Sobrenome
 
Termo De Uso do CEMIG atende (atualizado em 2023)
Termo De Uso do CEMIG atende (atualizado em 2023)Termo De Uso do CEMIG atende (atualizado em 2023)
Termo De Uso do CEMIG atende (atualizado em 2023)
Nome Sobrenome
 
Manual Lavadora Karcher K 3390 K3390 K 3.390 BR
Manual Lavadora Karcher K 3390 K3390 K 3.390 BRManual Lavadora Karcher K 3390 K3390 K 3.390 BR
Manual Lavadora Karcher K 3390 K3390 K 3.390 BR
Nome Sobrenome
 
Manual do Motor Portão Eletronico Rossi DZ
Manual do Motor Portão Eletronico Rossi DZManual do Motor Portão Eletronico Rossi DZ
Manual do Motor Portão Eletronico Rossi DZ
Nome Sobrenome
 
Manual Motor ROSSI - catalogo da linha DZ
Manual Motor ROSSI - catalogo da linha DZManual Motor ROSSI - catalogo da linha DZ
Manual Motor ROSSI - catalogo da linha DZ
Nome Sobrenome
 
Manual Motor Portão Eletronico ROSSI DZ - manual de instalação
Manual Motor Portão Eletronico ROSSI DZ - manual de instalaçãoManual Motor Portão Eletronico ROSSI DZ - manual de instalação
Manual Motor Portão Eletronico ROSSI DZ - manual de instalação
Nome Sobrenome
 
Manual super mix fun kitchen funkitchen manual
Manual super mix fun kitchen funkitchen manualManual super mix fun kitchen funkitchen manual
Manual super mix fun kitchen funkitchen manual
Nome Sobrenome
 
Manual da pipoqueira britania pop time elétrica
Manual da pipoqueira britania pop time elétricaManual da pipoqueira britania pop time elétrica
Manual da pipoqueira britania pop time elétrica
Nome Sobrenome
 
Manual da panela de pressão Nigro Eterna
Manual da panela de pressão Nigro EternaManual da panela de pressão Nigro Eterna
Manual da panela de pressão Nigro Eterna
Nome Sobrenome
 
Manual da Repouseira Cadeirinha Descanso Care Star Baby
Manual da Repouseira Cadeirinha Descanso Care Star BabyManual da Repouseira Cadeirinha Descanso Care Star Baby
Manual da Repouseira Cadeirinha Descanso Care Star Baby
Nome Sobrenome
 
Manual dvr intelbras serie 3000 3104 3108 3116
Manual dvr intelbras serie 3000 3104 3108 3116Manual dvr intelbras serie 3000 3104 3108 3116
Manual dvr intelbras serie 3000 3104 3108 3116
Nome Sobrenome
 
Hikvision rtsp url streaming tutorial manual
Hikvision rtsp url streaming tutorial manualHikvision rtsp url streaming tutorial manual
Hikvision rtsp url streaming tutorial manual
Nome Sobrenome
 
Manual PPA - P16261 - automatizadores deslizantes CE
Manual PPA - P16261 - automatizadores deslizantes CEManual PPA - P16261 - automatizadores deslizantes CE
Manual PPA - P16261 - automatizadores deslizantes CE
Nome Sobrenome
 
PPA - Gabarito base de furacao - DZ PREDIAL
PPA - Gabarito base de furacao - DZ PREDIALPPA - Gabarito base de furacao - DZ PREDIAL
PPA - Gabarito base de furacao - DZ PREDIAL
Nome Sobrenome
 
PPA - MANUAL TRIFLEX CONNECT P04722 rev2
PPA - MANUAL TRIFLEX CONNECT P04722 rev2PPA - MANUAL TRIFLEX CONNECT P04722 rev2
PPA - MANUAL TRIFLEX CONNECT P04722 rev2
Nome Sobrenome
 
Manual do Modulo Relé para Sinaleira PPA
Manual do Modulo Relé para Sinaleira PPAManual do Modulo Relé para Sinaleira PPA
Manual do Modulo Relé para Sinaleira PPA
Nome Sobrenome
 
Manual da Lavadora Brastemp - BWJ09AB - Guia Rápido
Manual da Lavadora Brastemp - BWJ09AB - Guia RápidoManual da Lavadora Brastemp - BWJ09AB - Guia Rápido
Manual da Lavadora Brastemp - BWJ09AB - Guia Rápido
Nome Sobrenome
 
Manual da Lavadora Brastemp - BWJ09AB - instruções
Manual da Lavadora Brastemp - BWJ09AB - instruçõesManual da Lavadora Brastemp - BWJ09AB - instruções
Manual da Lavadora Brastemp - BWJ09AB - instruções
Nome Sobrenome
 
Manual do Aspirador de Pó Philco PH1100 Turbo
Manual do Aspirador de Pó Philco PH1100 TurboManual do Aspirador de Pó Philco PH1100 Turbo
Manual do Aspirador de Pó Philco PH1100 Turbo
Nome Sobrenome
 

More from Nome Sobrenome (20)

Manual Karcher K3390 K 3390 - lista de peças de reposição part number
Manual Karcher K3390 K 3390 - lista de peças de reposição part numberManual Karcher K3390 K 3390 - lista de peças de reposição part number
Manual Karcher K3390 K 3390 - lista de peças de reposição part number
 
Quansheng TG UV2 TGUV2 - complete user manual
Quansheng TG UV2 TGUV2 - complete user manualQuansheng TG UV2 TGUV2 - complete user manual
Quansheng TG UV2 TGUV2 - complete user manual
 
Termo De Uso do CEMIG atende (atualizado em 2023)
Termo De Uso do CEMIG atende (atualizado em 2023)Termo De Uso do CEMIG atende (atualizado em 2023)
Termo De Uso do CEMIG atende (atualizado em 2023)
 
Manual Lavadora Karcher K 3390 K3390 K 3.390 BR
Manual Lavadora Karcher K 3390 K3390 K 3.390 BRManual Lavadora Karcher K 3390 K3390 K 3.390 BR
Manual Lavadora Karcher K 3390 K3390 K 3.390 BR
 
Manual do Motor Portão Eletronico Rossi DZ
Manual do Motor Portão Eletronico Rossi DZManual do Motor Portão Eletronico Rossi DZ
Manual do Motor Portão Eletronico Rossi DZ
 
Manual Motor ROSSI - catalogo da linha DZ
Manual Motor ROSSI - catalogo da linha DZManual Motor ROSSI - catalogo da linha DZ
Manual Motor ROSSI - catalogo da linha DZ
 
Manual Motor Portão Eletronico ROSSI DZ - manual de instalação
Manual Motor Portão Eletronico ROSSI DZ - manual de instalaçãoManual Motor Portão Eletronico ROSSI DZ - manual de instalação
Manual Motor Portão Eletronico ROSSI DZ - manual de instalação
 
Manual super mix fun kitchen funkitchen manual
Manual super mix fun kitchen funkitchen manualManual super mix fun kitchen funkitchen manual
Manual super mix fun kitchen funkitchen manual
 
Manual da pipoqueira britania pop time elétrica
Manual da pipoqueira britania pop time elétricaManual da pipoqueira britania pop time elétrica
Manual da pipoqueira britania pop time elétrica
 
Manual da panela de pressão Nigro Eterna
Manual da panela de pressão Nigro EternaManual da panela de pressão Nigro Eterna
Manual da panela de pressão Nigro Eterna
 
Manual da Repouseira Cadeirinha Descanso Care Star Baby
Manual da Repouseira Cadeirinha Descanso Care Star BabyManual da Repouseira Cadeirinha Descanso Care Star Baby
Manual da Repouseira Cadeirinha Descanso Care Star Baby
 
Manual dvr intelbras serie 3000 3104 3108 3116
Manual dvr intelbras serie 3000 3104 3108 3116Manual dvr intelbras serie 3000 3104 3108 3116
Manual dvr intelbras serie 3000 3104 3108 3116
 
Hikvision rtsp url streaming tutorial manual
Hikvision rtsp url streaming tutorial manualHikvision rtsp url streaming tutorial manual
Hikvision rtsp url streaming tutorial manual
 
Manual PPA - P16261 - automatizadores deslizantes CE
Manual PPA - P16261 - automatizadores deslizantes CEManual PPA - P16261 - automatizadores deslizantes CE
Manual PPA - P16261 - automatizadores deslizantes CE
 
PPA - Gabarito base de furacao - DZ PREDIAL
PPA - Gabarito base de furacao - DZ PREDIALPPA - Gabarito base de furacao - DZ PREDIAL
PPA - Gabarito base de furacao - DZ PREDIAL
 
PPA - MANUAL TRIFLEX CONNECT P04722 rev2
PPA - MANUAL TRIFLEX CONNECT P04722 rev2PPA - MANUAL TRIFLEX CONNECT P04722 rev2
PPA - MANUAL TRIFLEX CONNECT P04722 rev2
 
Manual do Modulo Relé para Sinaleira PPA
Manual do Modulo Relé para Sinaleira PPAManual do Modulo Relé para Sinaleira PPA
Manual do Modulo Relé para Sinaleira PPA
 
Manual da Lavadora Brastemp - BWJ09AB - Guia Rápido
Manual da Lavadora Brastemp - BWJ09AB - Guia RápidoManual da Lavadora Brastemp - BWJ09AB - Guia Rápido
Manual da Lavadora Brastemp - BWJ09AB - Guia Rápido
 
Manual da Lavadora Brastemp - BWJ09AB - instruções
Manual da Lavadora Brastemp - BWJ09AB - instruçõesManual da Lavadora Brastemp - BWJ09AB - instruções
Manual da Lavadora Brastemp - BWJ09AB - instruções
 
Manual do Aspirador de Pó Philco PH1100 Turbo
Manual do Aspirador de Pó Philco PH1100 TurboManual do Aspirador de Pó Philco PH1100 Turbo
Manual do Aspirador de Pó Philco PH1100 Turbo
 

Recently uploaded

Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...
Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...
Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...
jealousviolet
 
Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...
Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...
Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...
nightgirl
 
Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...
Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...
Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...
kishanaaani
 
Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...
Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...
Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...
fatima shekh$A17
 
Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...
nightgirl
 
Toronto Metropolitan University diploma
Toronto Metropolitan University diplomaToronto Metropolitan University diploma
Toronto Metropolitan University diploma
oqapy
 
Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...
Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...
Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...
fatima shekh$A17
 
Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...
Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...
Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...
sheetal singh$A17
 
Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...
Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...
Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...
avanikakapoor
 
Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...
Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...
Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...
fatima shekh$A17
 
Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...
Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...
Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...
miss ekta$A17
 
516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf
516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf
516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf
Hưng Nguyễn Trọng
 
Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...
Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...
Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...
eshikajshani
 
208749207-MBA-Project-on-Employee-welfare-measures.doc
208749207-MBA-Project-on-Employee-welfare-measures.doc208749207-MBA-Project-on-Employee-welfare-measures.doc
208749207-MBA-Project-on-Employee-welfare-measures.doc
manojtcet
 
Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...
soniya tomar
 
Mobile app marketing in hyd.ppt. ppt.pptx
Mobile app marketing in hyd.ppt. ppt.pptxMobile app marketing in hyd.ppt. ppt.pptx
Mobile app marketing in hyd.ppt. ppt.pptx
aayush3zen
 
BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...
BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...
BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...
3610stuck
 
Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...
Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...
Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...
bellared2
 
Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...
Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...
Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...
rachna yadav
 
Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...
Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...
Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...
Kavita Gupta
 

Recently uploaded (20)

Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...
Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...
Dating Girls Call Mumbai 9910780858 Provide Best And Top Girl Service And No1...
 
Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...
Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...
Premium Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And...
 
Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...
Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...
Shimla Girls Call Shimla 0X0000000X Provide Best And Top Girl Service And No1...
 
Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...
Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...
Delhi Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And No...
 
Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9833363713 💃 Choose Best And Top Girl Service And N...
 
Toronto Metropolitan University diploma
Toronto Metropolitan University diplomaToronto Metropolitan University diploma
Toronto Metropolitan University diploma
 
Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...
Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...
Verified Girls Call Delhi 🛵🚡9711199171 💃 Choose Best And Top Girl Service And...
 
Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...
Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...
Verified Girls Call Noida 🎈🔥9873940964 🔥💋🎈 Provide Best And Top Girl Service ...
 
Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...
Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...
Hyderabad Girls call 000XX00000 Provide Best And Top Girl Service And No1 in ...
 
Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...
Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...
Busty Girls Call Delhi 🎈🔥9711199171 🔥💋🎈 Provide Best And Top Girl Service And...
 
Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...
Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...
Busty Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service Ava...
 
516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf
516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf
516008895-Core-Ovation-Training-Reference-Manual-for-Ovation-3-5.pdf
 
Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...
Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...
Lucknow Girls Call Khujauli 08630512678 Provide Best And Top Girl Service And...
 
208749207-MBA-Project-on-Employee-welfare-measures.doc
208749207-MBA-Project-on-Employee-welfare-measures.doc208749207-MBA-Project-on-Employee-welfare-measures.doc
208749207-MBA-Project-on-Employee-welfare-measures.doc
 
Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...
Busty Girls Call Mumbai 🛵🚡9910780858 💃 Choose Best And Top Girl Service And N...
 
Mobile app marketing in hyd.ppt. ppt.pptx
Mobile app marketing in hyd.ppt. ppt.pptxMobile app marketing in hyd.ppt. ppt.pptx
Mobile app marketing in hyd.ppt. ppt.pptx
 
BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...
BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...
BDSM Girls Call Mumbai 🛵🚡9930687706 💃 Choose Best And Top Girl Service And No...
 
Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...
Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...
Exclusive Girls Call Navi Mumbai 🎈🔥9920725232 🔥💋🎈 Provide Best And Top Girl S...
 
Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...
Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...
Celebrity Girls Call Mumbai 9833363713 Unlimited Short Providing Girls Servic...
 
Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...
Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...
Premium Girls Call Delhi 9711199171 Unlimited Short Providing Girls Service A...
 

Hi8us hg01 v2 manual

  • 1. Hi8us Operating Instructions for Infrared Thermometer Model: HG01 Version: V2 Non-sterile Reserve forstandby application
  • 2. CONTENTS ear user: Thank you for purchasing the Infrared Thermometer of our company. he device is only to be used, maintained and serviced by personne tamiliar with the operating manual as well as the 'Important Safety ntormation'. The instruction should be reserved for standby application. 01. Important Safety Information 02. Product Benefits 03. Description Of Symbols 04. Intended Use 05. Features 06. Product Description 07. Technical Specifications 08. Use 09. Errors 10. Batteries Replacement 11. Cleaning and Maintenance 12. Electromagnetic Compatibility 13. Troubleshooting 14. Temperature Knowledge 15. After-Sale Service 16. Accessory (1)
  • 3. 1. Important Safety Information 1) This device must only be used for the purposes described in this operating instruction. The device is intended for professional or family use only. 2Thethermometer is not waterproof. Do not immense the device in water orinother liquids. Follow the instructions in Cleaning and Maintenance if needed. 3 Keep the themometer away from direct sunlight. Keep the thermometer in clean, dry environment (5~45°C, humidity <85%) 4) Do not touch the sensor inside the device. 5) It may affect the accuracy of measurements when one's forehead is cOvered by hair, perspiration, cap or scari. 6) Do not drop, dissemble, repair or transform the device. 7) Do not use the device near large electromagnetic fields for the accuracy of measurements maybe affected. 8) Should problem occur with your device, please contact your retailer. Do not attempt to repair the device by yourself. 9) If batteries or components are swallowed accidently, please comply with local laws and regulations. 10) Do not open the battery cover when testing in avoidance of electric shock. 11) The device should be used in stable temperature. If there exist sudden change in environment temperature, please notice if the sensor is covered by moist. Clean the moist as described in Cleaning and Maintenance before the next operation in order to get an accurate result. 12) When the device is out of service for long period, the batteries should be taken out in prevention of leakage. 13) Do not load the device with used and new batteries. Damage to the device may occur due to differences in discharge characteristics. Warning: Keep the deviceawayfrom children. Do not throw the device or batteries into fire Use ofthis thermometer is not intended as a substitute for consultation with your physician. (2)
  • 4. 2. Product Benefits Convenient and fast: measurements error up to t0.2°C, measuring time0.5-2s; Width ofmeasurements: 0.0-100°C; Various applications: 1) Human body temperature measurements; 2) Objects temperature measurements (eg. Rice paste temperature); 3) Liquids temperature measurements (eg. Bath water for babies, milk); Clean and hygienic: Non-contact measurements, measures distance 1-3cm, preventing cross-infection; Simple and practical: measures at one-press; mode switch at one-press; memorization query at one-press, simple for operation; Measurement Warning: measured temperature> 37.5°C the devicee alam song. Multiple memorizations: memorization of up to 32 measurements, easy for comparison Fix setting: parameters adjustable forsuiting different races or human bodies. 3. Description Of Symbols LOT batch number SN ProductSerial Number M Manufacturer Manufacturing date Caution: please refer to the manual Expiatory date Non-ionizing radiation signal Type-B application part (3)
  • 5. 4.Intended Use Human body temperature measurements: Objects temperature measurements (eg. Rice paste temperature) Liquids temperature measurements (eg. Bath water for babies, milk) 5.Features This thermometer is classified as type-B, inner electric power in terms of prevention degree of electric shock; This themometer is classified by its safety degree as follows: It can't be operated in an environment that contains flammable anesthetic gas, air, oxygen and Nitrous oxide; This thermometeris classified as No-Special-Protection according to GB4208 regulations; This thermometer is classified as Continuous operation equipment according to operating mode; Lists of accessories: Operating Instructions x 1; Certification x 1. 6.Product Description Product Composition = 2 1) Passive IR Sensor 2) LCD Display 3) Multifunction button group 4) ON/Scan Button 5) Battery Cover 5 (4)
  • 6. Product Description LCD Display Description 1) Surface Mode symbol 2) Body Mode symbol 3) Digital Layout 4) Measurements Layout 5) Battery Low Symbol 6) Volume On/Off Symbol 7) TemperatureC (Celsius)/°F(Fahrenheit) Scale 8) Memorized Measurements Serial Number 9) Memorization State Reminder 8 Objecttemperature Temperature 88 2Memory 8888 4 5 (5)
  • 7. 7. Technical Specifications Operating temperature: 16-35°C Humidity rate: s85% Power: DC 3V (2xAAbatteries) Size: 138 x 95 x 40 mm (Lx W x H) Weight: 90g Measuring range: In BodyMode: 32-42.9°C Accuracy: a) 32.0-34.9C: +0.3°C b)35.0-42.0°C: t0.2°C c)42.1-42.9°C: +0.3°C Measuring distance: 3-5cm Measuring time: 0.5-2s Temperature Mode: a) 32.0-37.4°C Normal b) >37.5C Alarm Automatic Stop: «=18s Storage Temperature and Humidity: -20°C-55°C; s93% If necessary, circuit diagram and list of components could be provided for repairing use for technical personnel. (6)
  • 8. 8. Use .BatteriesInstallation Press down and then backward at battery cover open, install 3.0VDC (wo AAA alkaline batteries), close the battery cover. Please notice the positive and negative poles on the batteries. Do not reverse the poles. Ready for Measurements Correct operation leads to accurate measurements, or else measurements erors may occur. In avoiding inaccuracies of the results, follow the instructions below: 1) Aim towards the center of one's forehead from a distance of 1-3cm and keeps vertical, then press the measuring key. The temperature is displayed on the indicator immediately; 2) Before measurements, please make sure there is no hair, perspiration, makeups or hat covered on the forehead; 3) Keep the device in the measuring environment for more than 5 minutes. Measures after the device's temperature becomes accordance with the measuring environment; 4) Cold compression and other cooling measures taken by the tested person may lead to lowered measurementsresults Measurements should avoid to be taken under such circumstances; 5) Measurements should be taken in stable temperature environment. Do not operate the device near to fan, air conditioner outlet where the airflow is strong; 6) Under the changing environment, the thermometer should be stable for 20 minutes before use. 7) The test object is suitable for all people, forehead or wrist, and the dlinical deviation is +0.2 C. (7)
  • 9. Use 8) If the device is not used for a long time, it should be place in the new operating environment for 30 minutes before measurements; 9) Do not operate the device in strong sunlight; 10) It's suggested that the most displayed result be taken for every 3 measurements; 11) To measure human body temperature, select 'Body temperature Mode'; To measure other objects, liquids and food temperature, select 'Object Temperature Mode; 12) If there are irresistible reasons that cause lowered temperature of forehead. You can take the temperature behind the earlobe; Starting toMeasure 1) Aim towards the forehead, press power button. LCD instructor would display all the numbers and symbols. The device will test the room temperature and will delay turning on for one or two seconds; 2) One 'beep' sound or three 'beep' sounds would be heard once the display is over, indicating the end of power-on measurements process. LCD would demonstrate the measured Odeer 88 Memory 8888 C Memory 368 target's temperature. At the same time, the backlight would flash one colors from green, yellow and red according to the setting; (8)
  • 10. Caution: When the temperature of high fever is set above the LCD display crying face, accompanied by 3 beep, beep, beep alarm sound. This is to warn the patient his/her possibility of having a fever. To ensure the accuracy of the measurement, please wait at least 30 seconds after 5 consecutive measurements. Shifting the Measuring Mode 1) When the power is on, press the 'Mode' button to select between 'Body temperature Mode' and 'Object Temperature Mode'. Measurements range of 'Object Temperature Mode' ranges at 0-100°C 2) Body Temperature Mode' is used to measure temperature of inner human body. Object Temperature' is used to measure temperature of surface of objects. (preset: Body Temperature Mode) (9)
  • 11. Memorization query In the on state, pressing the Memo' button allows user to enter memorization mode. To query on previous memorized values, press shortly on 'Memo' button. Note: 1) larger serial number identifies earlier values, vise versa. 2) Memorized values directly display if there exist values that have been memorized.If not," would be displayed as diagram in the right demonstrated. Tenperaure C 32 Memory 3) The device is capable for storing 32 groups of measurements values. The other ones would be covered automatically according to time sequence. (10)
  • 12. 1) Units Setting F1 (presets as Celsius) in the on state, long press the multi-function key (MODE) to enter F1, let go of F1 parameter, press the MEMO key or SET key (SET) to switch the units of Celsius and Fahrenheit, then press the multi-function key (MODE) to confirm the unit setting. and enter F2 at the same time. 2) In the F2 state, press SET to tum on the prompt sound, press MEMO to turn off the prompt sound, then press MODE to confim the setting and enter F3. 3) F3 is SET for highfever waming (factory setting is 38.1C). When entering F3 state, press the MEMO key to reduce 0.1C, press the SET key to add 0.1 C, then press the MODE to confim the alarm point setting, and enter F4 at the same time. 4) press SETto turn on the screenlight in the state of F4, press MEMO to turn off the screen light, and then press MODE to return to the test state. (11)
  • 13. 9. Errors LCD/problems meaning possible cause and solutions The value is above the measurements range selected, either superior to 42.9°C in Body mode or superior to 100°C in Object mode. Measured temperature over-high The value is below the measurements range selected, either minor to 32°C in Body mode or minor to 100°C in Object mode. Measured Lo temperature over-low Measured The device is not in operation Err temperature out of temperature. (<16°C or >35°C) range Error function alert After the system self-checked and 8888 error occurs, the screen flashes and automatically stops The battery power is low. The screen will turn off after the Lo" flashes. Please replace the battery immediately. BatteryIowalert ELO The environment temperature is unstable. Please place the device in stable environment for 30 minutes or more. Please make sure the battery is properly installed. Pay attention to the positive and negative poles of the batteries. Confirm whether the battery is still usable. Environment POS temperature unstable Blank screen (12)
  • 14. 10. Batteries Replacement The device uses 3.0VDC (two AAA alkaline batteries). When the device shows that the battery is low, please refer to Battery Installation chapter to change the batteries. Cautions: 1) When opening the battery cover, pay special attention to the poles of the batteries. Wrong poles could lead to damage to the device 2) After long period out of service, please take out the batteries in prevention of leakage. 3) When the battery leaks or molds, please do not use the batteries. 4) Do not take the batteries close to or throw them into fire in prevention of explosion 5) Do not store batteries in overheat or humid environment. 6) In prevention of short circuit, do not place batteries, coins, keys and other metal materials together in a pocket or in containers that could lead to short circuit problem. 11. Cleaning and Maintenance The infrared sensor is the most intricate partofthe device. Do not touch the sensor with fingers or other materials. Sensor should be under careful protection, or else the accuracy of measurements will be affected. Clean the device with a cotton bud lightly moistened with 70%-75% alcohol. Do not let the liquid enter inner body of the device. Do not clean the device with corrosive detergent. Do not immense the device with water or other liquids. (13)
  • 15. 12. Electromagnetic Compatibility Protects the surface of LCD carefully. Place the device in a dry environment, and keep it awayfrom dust, pollution and direct sunlight. Cleaning every half a year or less is suggested. Cautions: 1) User should install and operate the thermometer according to the Electromagnetic Compatibility information in the files attached to the device. 2) Portable product and RF communication equipment may affect the performance of the device. Avoid the disturbance of strong electromagnetic equipment, like mobile phones, microwaves. 3) For more information, please refer to Chapter 16. Cautions: Waming: The device should not operate next to or piled up with other equipment. If necessary, observation should be conducted in making sure it operates properly. Use of accessories and cables other than manufacturer-provided applications may cause extra radiation of infrared ray or lower capability of disturbance resistance. (14)
  • 16. 13. Troubleshooting Question 1: Why does the screen display 'Lo' in the same environment? Answer: Possibilities: 1) The measurements distance is too far. The device may have measured the temperature of the environment. The thermometer is designed to measure temperature within a distance of 1-3cm. The best distance is around 1cm. 2) The measurements position is improper. The thermometer should be aimed at the center of one's forehead and should be vertical 3) The measured person may have hair, perspiration, water over his forehead. The person may have been cooling compressed, Antipyretics prescribed, blown by cold wind. The measurements should be retaken after the measured person stay in a stable environment for 5-10 minutes. Very few people have lower forehead temperature than others when they were born. In this occasion, the results may remain to be Lo'. The user could select 'In Surface Mode' to measure the target as well as other people's forehead surface temperature. The comparison could be made under contrast. 4) overall temperature error. Question 2: Feels like the result is inaccurate when first use. Why? Answer: Advice for the 1st use are listed as follows: (15)
  • 17. Troubleshooting 1) Place the thermometer in a stable environment for more than 30 minutes; 2) Take the temperature of a person using a conventional thermometer, getting a 36.8°C result for instance; 3) Take the temperature of the same person using the non-contact infrared thermometer. Keep the 1-3 cm distance between the thermometer and the forehead, take care to remove any obstacle which could alter the measurements (hair, perspiration...). If the similar result is got, the non-contact infrared thermometer is properly. set and ready for use. Question 3: Is there any harm to human body using the infrared thermometer? Is there any radiation? Answer: Infrared thermometer is used to measure human body temperature by collecting infrared radiation of human body. It passively receives infrared radiation energy. It does not need to contact human body directly and does not bring cross infection of different human bodies. The thermometer has no radiation to human body, so it has no harm to human body. Question 4: The thermometer shows temperature over-high and over-low to all tested people, is it a product quality problem? Answer: This kind of problem is generally caused by the setting of the thermometer. It can be corrected according to user's instructions. (16)
  • 18. 14. Temperature Knowledge The human body is a complex biological comprehensive system. Body temperature is an important feature of human body and life. Usually, we check the temperature of forehead, cochlea, anus, oral cavity and underarms to evaluate our health condition. Different body parts own different regular temperature. Normal Normal Tested body part| temperature Age temperature Cochlea 35.8-38C 0-2 years old 36.4-38 C temperature Forehead 34.7-37.8C 3-10 years old 36.1-37.8°C temperature Oral 35.5-37.5°C 11-65 years old 35.9-37.6°C temperature Underarm 34.7-37.3°C >65 years old 35.8-37.5°C temperature Anus 36.6-38 C temperature Human body temperature changes with time within a day and is also affected by other external conditions such as age, gender, skin color, skin thickness and age. Specifications are listed in the table. There exist difference between female body temperature and male body temperature. Generally speaking, men are about 0.3C higher. Female body temperature during ovulation will rise 0.3 C to 0.5 C than usual. Therefore, we can use this to know whether a woman is in the ovulation period to facilitate heredity or contraception. (17)
  • 19. Temperature Knowledge The usual method is to use a thermometer to measure the basal body temperature of a female individual every day, and then convert it into a basal body temperature change curve chart, which can clearly see the ovulation period. 15. After-Sale Service This product enjoys a one-year free warranty with a shopping invoice from the date of purchase. Package and Operating Instructions are not covered by the warranty. We target the following damage caused bythe user, please forgive us for failing to provide Free warranty service for the following conditions: 1) Failure caused by unauthorized refitting and refitting of products. 2) Failure in the course of use or handling or inadvertent drop 3) Failure caused by disobedient operation towards the instructions 4) Failure caused by lack of reasonable maintenance Warranty outside the range of the repair services would be charged according to the corresponding provisions. In request forwarranty service, please take the device to the dealers' point. (18)
  • 20. 16. Accessory Announcement of Guiders and Manufacturers This infrared thermometer is intended for use in the electromagnetic environment specified below. Purchaser or user of this infrared thermometer should ensure that it is operated in such electromagnetic environment. Emission experiment Compliance Electromagnetic Environment-Guidance The thermometer is only used for its internal functions, so its radio Group 1 frequency emissions are low. The possibility ofinterference to nearby electronic equipment is very low. Radio frequency emission GB4824 The infrared thermometer is suitable| to use in all equipment, including domestic installations and Radio frequency emission GB4824 Harmonic emissionInadequatelinstallations directly connected to GB17625.1 VoltageFluctuation/ Flashover Emission Inadequate| GB17625.2 Type B residential and public low-voltage power grids. (19)
  • 21. Accessory Announcement ofguiders and manufacturer- Electromagnetic immunity Thisinfrared thermometer is intended for use in the current environment specified below. Purchaser or user of this infrared thermometer should ensure it's operated in such current environment. Ec60601 Experimental level Immunityy Experiment Electrostatic t6KV Contact discharge GB/T17526.2 8KV Air Compliance Electromagnetic Environment Guidance The floor should be wood, concrete or tile. If | discharge thefloor is covered with synthetic material, the discharge relative humidity shall be Jat least 30% level t6KV Contact discharge discharge 8KV Air Electrical |transient pulse group GB/T 17626.4 Surg GB/T 7626.11 2KV To Ground Voltage sag, transient interruption and| 40%UT, Lasts for 5circles voltage change (on UT, >60% sag) of input cable GB/T 17626.5 circles (on UT, >30%sag) :2KV Powercable 1KV Output input cable Inadequate Inadequate 1KV ToGround Inadequate Inadequate <5%UT,Lastsfor0.5 circles (on UT, >95%sag) 70%UT, Lasts for 25 Inadequate Inadequate <5%UT,Lastsfor 5s (on UT, >95%sag) Power requencyy electric field (50-60Hz) GB/T 17626.8 The power frequency magnetic field should own 3A/m 50/60Hz|the characteristic of power requency magneticfield in typical commercial or hospital environment. Note: Ur refers to AC network voltage before test voltage application. 3A/m (20)
  • 22. Accessory Announcementof Guiders and Manufacturer - Electromagnetic Immunity This infrared thermometer is intended for use in the Electro alkali environment specifed below. Purchaseror user of this infrared thermometer should ensure it's operated in such Electroalkalienvironment. Experimenton IEC60601 Electromagnetic Experimental level immunity RF conduction 3V (valid) (GB/T 17626.6) 150KHz-80M for I radiation (GB/T 17626.3) |3V/M ComplianceElectromagnetic Environment Guidance level Inadequate |Portable and mobile RF communication equipment should not be used closer to any part of this infrared thermometerthan the recommended isolation point,including cables. The distance shall be calculatedby| the formula corresponding to the Hz 3VIM 80MHz-2.5G Hz Note1: At 80MHz and 800 MHz, theformularansmtterfrequency of higher frequency band is adopted. Note2: These guidelines may not apply to all situations. Electromagnetic propagation D1.2VP 80MHz-800MHz is affected by the absorption and refiectionD=2.3VP 80OMHz-2.5GHz of buildings, objects and human body. Recommended separation distance D=1.2 P Formula: P-Accords to the maximum rated output A Fixed generator,for example:base stationspower of transmitter provided on the of wireless (cellularlcordless) telephones and transmitter license (W) ground mobile radios, amateurradios, AM and D-Recommended separation distance (m) FM radio broadcasts, and television broadcasts, The field strength of the fixed RF the field strength cannot be predicted accurately. |transmitter is determined by the In order to evaluate the electromagnetic environment offixed RF transmitter, observation Irange, Dshould be lower than the of real electromagneticfield should be considered. [compliancelevel. f the feld strength of the infrared thermometer is higher thantheapplicableRFcompliance level, thedevice should be observed and verified.Ifabnormal perfomance is observed, additional measure is necessary to be taken. For example, to adjust the direction or position of the infrared thermometer. The wholefrequencyrangeshould be around 150KHz-80MHz, while the field strength should be lowerthan 3V/m. electromagnetic survey. In each frequency (21)
  • 23. Accessory Recommended Isolation Distance Between the Portable and Mobile Communication Equipment and the Infrared Thermometer The infrared thermometer isexpectedtobeusedin the electromagnetic environment controlled by radio frequency radiation disturbance. According to the maximum rated output power of the communication equipment, the buyer or user can maintain the variable and mobile radio frequency through the following recommendations lsolation distance corresponding to different frequencies of transmitter (m) Maximum rated output power of transmitter (W) 150 KHZ-80MHZd =12P 80 KHZ-80OMHZ d 80KHZ-2.5GhZ d 12NP 12VP 0.01 Inadequate 0.12 0.23 0.1 Inadequate 0.38 0.73 1 Inadequate 1.2 2.3 10 Inadequate 3.8 7.3 100 Inadequate 12 23 For transmitters not listed in the above table, d refers to the recommended isolation distance of rated maximum output power(m), which can be determined by the formula in the corresponding transmitter frequency column. P refers to the transmitters maximum output rating(W) provided by the transmitter manufacturer Note1: Formula of higher frequency range on 8OMHZ and 80OMHz frequencies should be applied Note2: These guidelines may not be suitable for all situations. Electromagnetic propagation is affected by absorption and reflection of buildings, objects and human body. (22)
  • 24. Filing Certificate number (Emergency codel Technical requirement code): medical device manufacturer license number: 20200041 Medical Device registration number: 20202070605 Model Number: HGO01 Version: Vv2 Manufacturer:Hunan Honggao Electronic Technology Co.,td Addres: Block 5, Comprehensive Industrial Park, Tenghui Pioneer Park, Nanxian Economic Development Zone, Yiyang, Hunan Province Tel:0769-83562008