SlideShare a Scribd company logo
1 of 23
Download to read offline
Membranes
INDEX
Membranes............................................................................................................................................................. 3
Membranes
Code: 090001
Filmtec RO membranes TFC TW30 1812 - 50, 75, 100 GPD (25)
Variants
Code Description
090001-01 Filmtec RO membrane TFC TW30 1812 - 50 GPD (25)
090001-02 Filmtec RO membrane TFC TW30 1812 - 75 GPD (25)
090001-03 Filmtec RO membrane TFC TW30 1812 - 100 GPD (25)
Code: 090005
Greenfilter RO membranes TFC 1812/2012/3012/3013 - 50, 75,
100, 150, 180, 300, 400 GPD
Variants
Code Description
090005-50 Greenfilter RO membrane TFC 1812 - 50 GPD (25)
090005-75 Greenfilter RO membrane TFC 1812 - 75 GPD (25)
090005-100 Greenfilter RO membrane TFC 1812 - 100 GPD (25)
090005-180 Greenfilter RO membrane TFC 2012 - 180 GPD (25)
090005-300 Greenfilter RO membrane TFC 3012 - 300 GPD (1)
090005-400 Greenfilter RO membrane TFC 3013 - 400 GPD (1)
Definition
Reverse osmosis process is based on nature and has been used for more than 30 years. These semi-
permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the
process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.3 ”m.
2. Polysulfone 45 ”m .
3. Non woven fabric polyester 100 ”m.
Spacer: EPDM
16 September 2022 3/23
SPECIFICATIONS OF PRODUCT
Membrane 50 GPD Cod. 090005-50
Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 75 GPD Cod. 090005-75
Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 100 GPD Cod. 090005-100
Active surface: 0,46mÂČ(5ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 150 GPD Cod. 090005-150
Active surface: x,xxmÂČ(xftÂČ) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts
rejection(N2) 97,5% * Recovery del 15%
Membrane 180 GPD Cod. 090005-180
Active surface: x,xxmÂČ(xftÂČ) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts
rejection(N2) 93% * Recovery del 15%
Membrane 300 GPD Cod. 090005-300
Active surface: x,xxmÂČ(xftÂČ) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts
rejection(N2) 95% * Recovery del 15%
Membrane 400 GPD Cod. 090005-400
Active surface: x,xxmÂČ(xftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts
rejection(N2) 95% * Recovery del 15%
(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ÂșC (77ÂșF),
15% recovery
and specified applied pressure. Permeated flows for individual elements may vary +/- 15%.
(N2) Minimum SALT rejection is 95%
OPERATING LIMITS OF 50, 75, 100 GPD
* Max. temperature 45ÂșC (113ÂșF)
* Max. pressure 21 bar (300 psi)
* Max. P for element 1 bar (15 psi)
* Max feed flow rate 7,6 lpm (2.0 gpm)
* pH range, continuous operation 3 - 10
* pH range, short-term cleaning (30 min) 2 - 11
* Max. Feed SDI 5
* Free Chlorine toleranceÂč <0,1 ppm
OPERATING LIMITS OF 150, 180, 300,400 GPD
* Max. temperature 45ÂșC (113ÂșF)
* Max. pressure 8,6 bar (125 psi)
* Max feed flow rate 7,6 lpm (2.0 gpm)
* pH range, continuous operation 3 - 10
* Free Chlorine toleranceÂč <0,1 ppm
ÂčUnder certain conditions, the presence of free chlorine and other oxidizing agents will cause premature
membrane failure.
We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We
recommend replacing it every 24 months max.
GENERAL INFORMATION
‱ All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite
and propylene glycol to prevent biological growth in short-term storage and transport.
16 September 2022 4/23
‱ It is suggested that firs hour of pure water to be rejected.
‱ Keep elements moist after initial wetting.
‱ To prevent biological growth during prolonged system shutdown, it is recommended that membrane
elements be immersed in a preservative solution.
‱ The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous
exposure, however, may damage the membrane and should be avoided.
‱ The customer is fully responsible for effects of incompatible chemicals and lubricants on elements.
‱ Use just glycerine as a lubricant if is needed.
‱ The use of this product in and of itself does not necessarily guarantee the removal of cysts and
pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design
and on the operation and maintenance of the system.
Code: 090018
Greenfilter RO encapsulated membranes TFC 50, 75, 100 GPD
Variants
Code Description
090018-01 Greenfilter RO encapsulated membrane TFC 50 GPD
090018-02 Greenfilter RO encapsulated membrane TFC 75 GPD
090018-03 Greenfilter RO encapsulated membrane TFC 75 GPD Filmtec
090018-04 Greenfilter RO encapsulated membrane TFC 100 GPD
High efficiency, disposable encapsulate membranes.
Change complete of vessel + membrane for maximum hygiene!
These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive
salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.3 ”m.
2. Polysulfone 45 ”m .
3. Non woven fabric polyester 100 ”m.
Spacer: EPDM
SPECIFICATIONS OF PRODUCT
Membrane 50 GPD Cod. 090018-01
Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 75 GPD Cod. 090018-02
Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 75 GPD Cod. 090018-03 FilmtecÂź
Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts
rejection(N2) 97% * Recovery 15%
16 September 2022 5/23
Membrane 100 GPD Cod. 090018-04
Active surface: 0,46mÂČ(5ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts
rejection(N2) 97% * Recovery 15%
(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ÂșC (77ÂșF),
15% recovery
and specified applied pressure. Permeated flows for individual elements may vary +/- 15%.
(N2) Minimum SALT rejection is 95%
Connections:
* Inlet water: O.D. stem Ø 3/8"
* Outlet permeate: O.D. stem Ø 1/4"
* Drain: O.D. stem Ø 1/4"
OPERATING LIMITS OF 50, 75, 100 GPD
* Max. temperature 45ÂșC (113ÂșF)
* Max. pressure 21 bar (300 psi)
* Max. P for element 1 bar (15 psi)
* Max feed flow rate 7,6 lpm (2.0 gpm)
* pH range, continuous operation 3 - 10
* pH range, short-term cleaning (30 min) 2 - 11
* Max. Feed SDI 5
* Free Chlorine toleranceÂč <0,1 ppm
ÂčUnder certain conditions, the presence of free chlorine and other oxidizing agents will cause premature
membrane failure.
We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We
recommend replacing it every 24 months max.
GENERAL INFORMATION
‱ It is suggested that firs hour of pure water to be rejected.
‱ Keep elements moist after initial wetting.
‱ The membrane has a certain short-term resistance against chlorine (hypochlorite). Continuous exposure,
however, may damage the membrane and should be avoided.
‱ The customer is fully responsible for effects of incompatible chemicals and lubricants on elements.
‱ Use just glycerine as a lubricant if is needed.
‱ The use of this product in and of itself does not necessarily guarantee the removal of cysts and
pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design
and on the operation and maintenance of the system.
Note: The polluting agents removed or reduced by this system are not necessarily in your water.
Code: 090017
Ionicore USmotic RO membranes TFC 2012 - 50, 75, 100, 150,
180 GPD (25)
Features
Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day)
Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day)
Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day)
16 September 2022 6/23
Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day)
Permeate flow rate (+/-20%) 180: 180 Gpd (681 lt./day)
Minimum salt rejection: 96%
Stabilized salt rejection: 98%
Operating pressure test: 65 PSI
TDS feed test: Tap Water (from 450 to 700 ppm)
Water temperature test: 77°F. (25°C.)
Recovery test: 15%
Max. operating pressure: 125 - 300 PSIG
Max. feed SDI: 5 (15 min)
Max. feed flow rate: 2 gal./min. (7,57 lt./min.)
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 2-11
Max. feed water turbidity: 1 NTU
Membrane style: Dry
Variants
Code Description
090017-050 Ionicore USmotic RO membrane TFC 2012 - 50GPD (25)
090017-075 Ionicore USmotic RO membrane TFC 2012 - 75GPD (25)
090017-100 Ionicore USmotic RO membrane TFC 2012 - 100GPD (25)
090017-150 Ionicore USmotic RO membrane TFC 2012 - 150GPD (25)
090017-180 Ionicore RO USmotic membrane TFC 2012 - 180GPD (25)
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents
the better water filtration technique, because is not a simply unwanted substances reduction but is able to
remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally
made of polyamide (PA).
These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons
per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the
reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M.
174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS),
delivering healthier and safer drinking water.
Features:
* High Rejection & Flow Rate
* Made in the USA
* ISO 9001:2008 Certified
* Standard dimensions: can be fitted in any RO systems
* Max. inlet Hardness: 25°F. (250ppm)
* Max. Free Chlorine: 0.1 ppm
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.2 ”m.
2. Polysulfone 40 ”m.
3. Non woven fabric polyester 120 ”m.
Spacer: EPDM
Active surface:
50 GPD 0.35 m2 (3.8 sq. ft)
75 GPD 0.35 m2 (3.8 sq. ft)
100 GPD 0.52 m2 (5.6 sq. ft)
150 GPD 0.58 m2 (6.2 sq. ft)
180 GPD 0.64 m2 (6.9 sq. ft)
TFC Nominal Rejection Characteristics:
16 September 2022 7/23
Calcium: 93-98%
Sodium: 92-98%
Magnesium: 93-98%
Potassium: 92-96%
Manganese: 96-98%
Iron: 96-98%
Aluminum: 96-98%
Copper: 96-98%
Nickel: 96-98%
Cadmium: 93-97%
Silver: 93-96%
Zinc: 96-98%
Mercury: 94-97%
Hardness Ca & Mg: 93-97%
Radioactivity: 93-97%
Chloride: 92-95%
Ammonium: 80-90%
Bromide: 90-95%
Phosphate: 95-98%
Chromate: 85-95%
Cyanide: 85-95%
Sulfate: 96-98%
Thiosulfate: 96-98%
Silicate: 92-95%
Silica: 80-90%
Nitrate: 90-95%
Boron: 50-70%
Borate: 30-50%
Fluoride: 92-95%
Polyphosphate: 96-98%
Orthophosphate: 96-98%
Chromate: 85-95%
Virus and Bacteria: 99% +
Lead: 95-98%
The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the
feed water.
WARNING
The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water)
and it works only if it's installed on water complies with the law, municipal potable water or well water if
previously made drinkable with adequate and effective systems, preventively studied and personalized for
that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown
quality without adequate disinfection before and after the system. All systems must be preserved according
to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in
your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.
16 September 2022 8/23
Code: 090026
Ionicore Keypra RO membranes TFC 1812/2012 - 50, 75, 100,
150, 200 GPD (25)
Features
Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day)
Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day)
Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day)
Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day)
Permeate flow rate (+/-20%) 200: 200 Gpd (757 lt./day)
Minimum salt rejection: 97%
Stabilized salt rejection: 98%
Operating pressure test: 60 PSI
TDS feed test: Tap Water (from 250 to 700 ppm)
Water temperature test: 77°F. (25°C.)
Recovery test: 15%
Max. operating pressure: 125 PSIG / 0.86 MPa (8,6 Bar)
Max. feed SDI: 5 (15 min)
Max. feed flow rate: 2 gal./min. (7,57 lt./min.)
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 2-11
Max. feed water turbidity: 1 NTU
Membrane style: Dry
Variants
Code Description
090026-050 Ionicore Keypra RO membrane TFC 1812 - 50GPD (25)
090026-075 Ionicore Keypra RO membrane TFC 1812 - 75GPD (25)
090026-100 Ionicore Keypra RO membrane TFC 2012 - 100GPD (25)
090026-150 Ionicore Keypra RO membrane TFC 2012 - 150GPD (25)
090026-200 Ionicore Keypra RO membrane TFC 2012 - 200GPD (25)
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents
the better water filtration technique, because is not a simply unwanted substances reduction but is able to
remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally
made of polyamide (PA).
These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 200 Gallons
per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the
reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M.
174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS),
delivering healthier and safer drinking water.
Features:
* High Rejection & Flow Rate
* Standard dimensions: can be fitted in any RO systems
* Max. inlet Hardness: 25°F. (250ppm)
* Max. Free Chlorine: 0.1 ppm
16 September 2022 9/23
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.2 ”m.
2. Polysulfone 40 ”m.
3. Non woven fabric polyester 120 ”m.
Spacer: EPDM
Active surface:
50 GPD 0.37 m2 (3.9 sq. ft)
75 GPD 0.40 m2 (4.3 sq. ft)
100 GPD 0.40 m2 (4.3 sq. ft)
150 GPD 0.58 m2 (6.2 sq. ft)
200 GPD 0.77 m2 (8.2 sq. ft)
TFC Nominal Rejection Characteristics:
Calcium: 93-98%
Sodium: 92-98%
Magnesium: 93-98%
Potassium: 92-96%
Manganese: 96-98%
Iron: 96-98%
Aluminum: 96-98%
Copper: 96-98%
Nickel: 96-98%
Cadmium: 93-97%
Silver: 93-96%
Zinc: 96-98%
Mercury: 94-97%
Hardness Ca & Mg: 93-97%
Radioactivity: 93-97%
Chloride: 92-95%
Ammonium: 80-90%
Bromide: 90-95%
Phosphate: 95-98%
Chromate: 85-95%
Cyanide: 85-95%
Sulfate: 96-98%
Thiosulfate: 96-98%
Silicate: 92-95%
Silica: 80-90%
Nitrate: 90-95%
Boron: 50-70%
Borate: 30-50%
Fluoride: 92-95%
Polyphosphate: 96-98%
Orthophosphate: 96-98%
Chromate: 85-95%
Virus and Bacteria: 99% +
Lead: 95-98%
The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the
feed water.
WARNING
The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water)
and it works only if it's installed on water complies with the law, municipal potable water or well water if
previously made drinkable with adequate and effective systems, preventively studied and personalized for
16 September 2022 10/23
that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown
quality without adequate disinfection before and after the system. All systems must be preserved according
to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in
your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.
Code: 090025
Ionicore Keypra RO membranes TFC 3012/3013 - 300, 400 GPD
(9)
Features
Permeate flow rate (+/-20%) 300: 300 Gpd (1.135 lt./day)
Permeate flow rate (+/-20%) 400: 400 Gpd (1.514 lt./day)
Minimum salt rejection: 97%
Stabilized salt rejection: 97%
Operating pressure test: 100 PSI
TDS feed test: 250 ppm
Water temperature test: 77°F. (25°C.)
Recovery test: 15%
Max. operating pressure: 300 PSIG / 2.06 MPa (20,6 Bar)
Max. feed SDI: 5 (15 min)
Max. feed flow rate: 2 gal./min. (7,57 lt./min.)
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 3-10
Max. feed water turbidity: 1 NTU
Membrane style: Dry
Variants
Code Description
090025-300 Ionicore Keypra RO membrane TFC 3012 - 300GPD (9)
090025-400 Ionicore Keypra RO membrane TFC 3013 - 400GPD (9)
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents
the better water filtration technique, because is not a simply unwanted substances reduction but is able to
remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally
made of polyamide (PA).
These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 400 Gallons
per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the
reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M.
174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS),
delivering healthier and safer drinking water.
Features:
* High Rejection & Flow Rate
* ISO 9001:2008 Certified
* Standard dimensions: can be fitted in any RO systems
* Max. inlet Hardness: 25°F. (250ppm)
* Max. Free Chlorine: 0.1 ppm
16 September 2022 11/23
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.2 ”m.
2. Polysulfone 40 ”m.
3. Non woven fabric polyester 120 ”m.
Spacer: EPDM
Active surface:
300 GPD 1.14 m2 (12.3 sq. ft)
400 GPD 1.42 m2 (15.3 sq. ft)
TFC Nominal Rejection Characteristics:
Calcium: 93-98%
Sodium: 92-98%
Magnesium: 93-98%
Potassium: 92-96%
Manganese: 96-98%
Iron: 96-98%
Aluminum: 96-98%
Copper: 96-98%
Nickel: 96-98%
Cadmium: 93-97%
Silver: 93-96%
Zinc: 96-98%
Mercury: 94-97%
Hardness Ca & Mg: 93-97%
Radioactivity: 93-97%
Chloride: 92-95%
Ammonium: 80-90%
Bromide: 90-95%
Phosphate: 95-98%
Chromate: 85-95%
Cyanide: 85-95%
Sulfate: 96-98%
Thiosulfate: 96-98%
Silicate: 92-95%
Silica: 80-90%
Nitrate: 90-95%
Boron: 50-70%
Borate: 30-50%
Fluoride: 92-95%
Polyphosphate: 96-98%
Orthophosphate: 96-98%
Chromate: 85-95%
Virus and Bacteria: 99% +
Lead: 95-98%
The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the
feed water.
WARNING
The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water)
and it works only if it's installed on water complies with the law, municipal potable water or well water if
previously made drinkable with adequate and effective systems, preventively studied and personalized for
that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown
quality without adequate disinfection before and after the system. All systems must be preserved according
to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in
16 September 2022 12/23
your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.
Code: 090019
Pentair RO encapsulated membranes TLC GRO 36, 50, 75 GPD
(16)
Variants
Code Description
090019-01 Pentair RO encapsulated membrane TLC GRO-36EN GPD (16)
090019-02 Pentair RO encapsulated membrane TLC GRO-50EN GPD (16)
090019-03 Pentair RO encapsulated membrane TLC GRO-75EN GPD (16)
GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high
quality reverse osmosis water while wasting 3 times less water to the drain.
Features
* TLC Thin Layer Composite membrane.
* 100% dry membrane maximizing shelf life.
* Double the recovery over standard RO elements.
* High rejection stability at high input TDS.
* Maximal Pressure: 6.90 bar.
* Maximal Temperature: 49°C.
* pH: 4-11.
* Free Chlorine: 0.1 ppm.
Connections:
* Inlet water: 1/4" Quick Fit..
* Outlet permeate: 1/4" Quick Fit.
* Drain: 1/4" Quick Fit.
Benefits
* 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO)
* High performances even under extreme conditions.
* Membrane can be stored for a longer period of time.
Nominal performance GRO-36EN
* Flow* Gpd (Lpd): 36 (136.3);
* Rejection: 96%;
* Drain flow control (ml./min.): 100.
Nominal performance GRO-50EN
* Flow* Gpd (Lpd): 50 (189.3);
* Rejection: 96%;
* Drain flow control (ml./min.): 150.
Nominal performance GRO-75EN
* Flow* Gpd (Lpd): 75 (283.9);
* Rejection:96%;
* Drain flow control (ml./min.): 200.
16 September 2022 13/23
Nota bene: The data above is based on internal laboratory testing.
* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ÂșC, 50% recovery after
24 hours. Individual element flux may vary ± 15%.
The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against
NSF/ANSI Standard 58 for materials and structural integrity requirements.
Here is the expected amount of water saved each year, for a family of 4 people:
Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt.
Standard RO membrane: 17’520 lt. of rejected water.
GRO membrane: 4’380 lt. of rejected water.
The use of GRO membranes allows a saving of about 13’000 lt. of water per year.
Code: 090012
Pentair RO membranes TLC 50, 75, 100 GPD (25)
Variants
Code Description
090012-050 Pentair RO membrane TLC - 50GPD (25)
090012-075 Pentair RO membrane TLC - 75GPD (25)
090012-100 Pentair RO membrane TLC - 100GPD (25)
TLCℱ RESIDENTIAL RO MEMBRANES
The best way to assess the overall filtration quality of a RO system is made by measuring the rejection,
which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the
rejection, the better the membrane performs. The recovery of a RO system represents the quantity of
permeate produced compared with the quantity of concentrate rejected to the drain. The higher the
recovery, the lower the rejection is.
RO MEMBRANE’S CONSTRUCTION
The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around
a perforated central tube. Purified water passes through the membrane and is collected in the permeate
collection material while rejected impurities stay in the feed channel spacer.
TLCℱ RANGE
TLCℱ (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any
types of needs from the customer. Dimensions of these membranes are standard; they will fit into any
reverse osmosis systems from the market.
FEATURES
‱ TLC Thin Layer Composite membrane
‱ 100% dry membrane maximizing shelf life
‱ High rejection stability at high input TDS
‱ Standard dimensions: can be fitted in any RO systems
‱ Maximal Pressure: 6.90 bar
‱ Maximal Temperature: 49°C
‱ pH: 4-11
‱ Hardness: 17°F
‱ Free Chlorine: 0.1 ppm
16 September 2022 14/23
‱ Rejection*: 98%
NOMINAL PERFORMANCE TLC-50
‱ Flow* Gpd (Lpd): 50 (189.3)
NOMINAL PERFORMANCE TLC-75
‱ Flow* Gpd (Lpd): 75 (283.9)
NOMINAL PERFORMANCE TLC-100
‱ Flow* Gpd (Lpd): 100 (378.5)
* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ÂșC, 15% recovery after
24 hours. Individual element flux may vary ± 15%.
BENEFITS OF TLCℱ MEMBRANES
100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag.
We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can
happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost
endless!
HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS
Whatever the amount of total dissolved solids from the inlet water, TLCℱ membranes will always give
optimal performances. When compared with a membrane from competition, we can clearly see that
Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at
1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**.
**Results obtained from internal testing (more testing results are available upon request)
NSF CERTIFIED
Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will
save time and money during the NSF certification process of the complete RO system by the OEM.
NSF COMPONENT
The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material
requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to
standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS
IMPORTANT INFORMATION
Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC
Membranes are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane
element performance can be affected by fluctuations in water quality.
Code: 090007
AMI RO membranes TFC 1812/3012 100, 150, 300 GPD (25)
16 September 2022 15/23
Variants
Code Description
090007-100 AMI RO membrane TFC 1812 - 100GPD (25)
090007-150 AMI RO membrane TFC 1812 - 150GPD (25)
090007-300 AMI RO membrane TFC 3012 - 300GPD (25)
AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of
thousands of membranes in operation world-wide, we offer these in a large range of both residential and
commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the
past 30 years AMI Membrane elements have earned the reputation of consistent quality.
Recommended Operating Conditions (50, 75, 100, 150gpd)
* Maximum operating pressure: 125 psi (8,61bar)
* Maximum feed flow rate: 2 gpm (7,57lt./min.)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 5
* Chlorine tolerance: <0.1 ppm
* Feed water pH range, Continuous Operation: 2-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Minimum brine flow to permeate flow ratio: 4:1
* Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm)
* Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm)
Note: Salt rejection and performance specifications shown are from internal test data.
Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C)
feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%.
The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits
loosely, you may need to wrap a few layers of tape near one end to make a tight fit.
Recommended Operating Conditions (300gpd)
* Maximum operating pressure: 300 psi (20,68bar)
* Maximum feed flow rate: 6 gpm (22,71lt./min.)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 4
* Chlorine tolerance: <0.1 ppm
* Feed water pH range, Continuous Operation: 2-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Single Element recovery: 15%
* Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm)
Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8
and 10% recovery. Element permeate flow may vary ± 15%.
Code: 090006
NF90-2012 nanofiltration RO membrane - 180GPD (25)
16 September 2022 16/23
Variants
Code Description
090006-01 NF90-2012 nanofiltration RO membrane - 180GPD (25)
ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide
composite membrane elements display an outsdanding salt rejection of more than 97% , superior product
water flow , high thermal and pressure durability , wide tolerance of chlorine and PH.
SPECIFICATIONS OF PRODUCT
Membrane 180GPD Cod. 090006-01 NF90-2012
NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD
Test condition
Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm *
Recovery: 15%
Operating limits
Max. temperature 40ÂșC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) *
Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm
Caution
Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to
stabilized
Code: 090002
Housings 2,5" for reverse osmosis membrane 1812, 2012 - 50,
75, 100, 150, 180 GPD
Variants
Code Description
090002-06 Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure 1/8" (20) (WE DON'T KNOW THE NEXT AVAILABILITY DA
090002-04 Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure double o-ring 1/8" (40)
090002-03 1812, 2012 Housing Wrench for cod. 090002-04
With double o-ring.
Code: 090021
Vessel for reverse osmosis membrane 3012 - 300GPD
16 September 2022 17/23
Connections
* Inlet: 1/4" * Outlet/Drain: 1/8"
Code: 090027
Vessel for reverse osmosis membrane 3012 - 300GPD quick
fittings connections clips
Variants
Code Description
090027-01 Vessel for reverse osmosis membrane 3012 - 300GPD quick fittings connections clips
The vessels are reverse osmosis membranes containers for domestic or industrial use, they can be used
with all the 3012 membranes series regardless model and brand, membranes with 300 gallons per day
(GPD) production performance.
They are usually used inside reverse osmosis systems and water purifiers with direct production or tank.
The vessel is supplied with quick fittings for a simple and quick installation with quick fitting clips.
Technical features:
- Material: polypropylene;
- Color: white;
- Maximum operating temperature: 45 ° C (113 ° F)
- Maximum operating pressure: 12 bar (174 psi)
- Connections: Inlet 3/8 "- Outlet / Drain: 1/4";
- Compatible membranes: 3012.
ATTENTION
Do not exceed indicated pressures in the technical specifications as the thrust pressure on the screwed cap
generates a considerable force.
Code: 090015
Vessel for reverse osmosis membrane 3013 - 400GPD quick
fittings connections clips
Variants
Code Description
090015-01 Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips
090015-02 3013 vessel wrench for cod. 090015-01
16 September 2022 18/23
Connections
* Inlet: 3/8" * Outlet/Drain: 1/4"
Code: 090022
Vessel for reverse osmosis membrane 3013 - 400GPD
Connections
* Inlet: 1/4" * Outlet/Drain: 1/8"
Code: 090023
Ionicore RO membranes TFC LP2521, LP2540, LP4040 Medium
pressure
Features
Permeate flow rate (+/-20%) LP2521: 300 gal./giorno (1.135 lt./giorno)
Permeate flow rate (+/-20%) LP2540: 750 gal./giorno (2.839 lt./giorno)
Permeate flow rate (+/-20%) LP4040: 2.500 gal./giorno (9.463 lt./giorno)
Minimum salt rejection: 98%
Stabilized salt rejection: 99%
Operating pressure test: 150 PSI (10,3 Bar)
TDS feed test: 1500 ppm
Water temperature test: 77°F. (25°C.)
Recovery test: 15%
Ph test: 7,5
Max. operating pressure: 600 PSIG / 4.23 MPa (42,3 Bar)
Max. feed SDI: 5 (15 min)
Max. feed flow rate: 16 gal./min. (60,55 lt./min.)
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 3-10
Variants
Code Description
090023-02 Ionicore RO membrane TFC LP2521 Medium pressure
090023-03 Ionicore RO membrane TFC LP2540 Medium pressure
090023-04 Ionicore RO membrane TFC LP4040 Medium pressure
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents
the better water filtration technique, because is not a simply unwanted substances reduction but is able to
16 September 2022 19/23
remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally
made of polyamide (PA).
These R.O. TFC(thin film composite) membranes are available with different flow rates. All models are
certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium
(Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium
and TDS and are certified D.M. m174/2004 (Italian Ministerial Decree).The membrane remove up to 99% of
total dissolved solids (TDS), delivering healthier and safer drinking water.
Features:
* ISO 9001:2008 Certified
* Max. inlet Hardness: 5°F. (50ppm)
* Max. Free Chlorine: 0.1 ppm
Active surface:
TFC LP2521: 1,3 m2 (14 sq. ft)
TFC LP2540: 2,6 m2 (28 sq. ft)
TFC LP4040: 8,4 m2 (90 sq. ft)
TFC Nominal Rejection Characteristics:
Calcium: 99%
Sodium: 99%
Magnesium: 99%
Potassium: 98%
Manganese: 99%
Iron: 99%
Aluminum: 99%
Copper: 99%
Nickel: 99%
Cadmium: 99%
Silver: 99%
Zinc: 99%
Mercury: 99%
Radioactivity: 98-99,3%
Chloride: 95-97%
Ammonium: 88-97%
Bromide: 94-96%
Phosphate: >99%
Chromate: 90-98%
Cyanide: 90-97%
Sulfate: 85-99%
Thiosulfate: 96-99%
Silicate: 95-97%
Silica: 80-98%
Nitrate: 93-96%
Boron: 80-86%
Borate: 35-70%
Fluoride: 94-96%
Polyphosphate: >99%
Orthophosphate: 98-99%
Chromate: 90-98%
Virus and Bacteria:100%
The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the
feed water.
16 September 2022 20/23
Code: 090013
Greenfilter RO membranes TFC LP2514, LP2521, LP2540,
LP4040 Medium pressure
Variants
Code Description
090013-04 Greenfilter RO membrane TFC LP2514 Medium pressure
090013-01 Greenfilter RO membrane TFC LP2521 Medium pressure
090013-02 Greenfilter RO membrane TFC LP2540 Medium pressure
090013-03 Greenfilter RO membrane TFC LP4040 Medium pressure
Code: 090024
Ionicore housings 2,5" and 4" for reverse osmosis membranes
2514, 2521, 2540, 4040x1 - 300psi SS304, FRP
Variants
Code Description
090024-01 Ionicore housing 2,5" for R.O. membrane 2514x1 - 300psi SS304
090024-02 Ionicore housing 2,5" for R.O. membrane 2521x1 - 300psi SS304
090024-03 Ionicore housing 2,5" for R.O. membrane 2540x1 - 300psi SS304
090024-04 Ionicore housing 4" for R.O. membrane 4040x1 - 300psi SS304
090024-10 Ionicore housing 2,5" for R.O. membrane 2514x1 - 300psi FRP
090024-11 Ionicore housing 2,5" for R.O. membrane 2521x1 - 300psi FRP
090024-12 Ionicore housing 2,5" for R.O. membrane 2540x1 - 300psi FRP
090024-13 Ionicore housing 4" for R.O. membrane 4040x1 - 300psi FRP
16 September 2022 21/23
Code: 090020
Housing 4" for reverse osmosis membrane 4040x1 - 300psi-EP
Greenfilter
Variants
Code Description
090020-02 Housing 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter
Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02
Features:
* Made of fiber reinforced polyester.
* Front connection, permeate the collection at both ends.
* Close by blocking half-length AISI-304 easy membrane replacement.
* EPDM seals. ABS collector plugs.
* Compatible with standard 4 "membranes.
* Support brackets included.
Connections:
* Inlet: 1/2" BSP F.
* Outlet/Drain: 3/4" BSP F
Technical features:
* Pressure: 21 kg/cm2, 21 bar (300 psi)
* Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi)
* Max. temperature: 49°C (120.2°F)
* Min. temperature: -10°C (14°F)
* pH range, continuous operation: 3-11
* pH range, short-term cleaning: 2-12 (max 30 min.)
* Weight: 6 kg
16 September 2022 22/23
Powered by TCPDF (www.tcpdf.org)

More Related Content

Similar to Membranes Catalog

Tds barrier 80 - english (uk) - issued.05.10.2011
Tds   barrier 80 - english (uk) - issued.05.10.2011Tds   barrier 80 - english (uk) - issued.05.10.2011
Tds barrier 80 - english (uk) - issued.05.10.2011Dhananjay Tekawade
 
Elastaseal data sheet
Elastaseal data sheetElastaseal data sheet
Elastaseal data sheetDale Stauffer
 
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENTCERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENTiQHub
 
Flexeon mktf 115-res_ro_pb_hr_locked
Flexeon mktf 115-res_ro_pb_hr_lockedFlexeon mktf 115-res_ro_pb_hr_locked
Flexeon mktf 115-res_ro_pb_hr_lockedAXEON Water Technologies
 

Similar to Membranes Catalog (20)

Filtri in linea catalogo
Filtri in linea catalogoFiltri in linea catalogo
Filtri in linea catalogo
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
In line filters catalogue
In line filters catalogueIn line filters catalogue
In line filters catalogue
 
In line filters catalog
In line filters catalogIn line filters catalog
In line filters catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
EQUIPMENT
EQUIPMENTEQUIPMENT
EQUIPMENT
 
Tds barrier 80 - english (uk) - issued.05.10.2011
Tds   barrier 80 - english (uk) - issued.05.10.2011Tds   barrier 80 - english (uk) - issued.05.10.2011
Tds barrier 80 - english (uk) - issued.05.10.2011
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Elastaseal data sheet
Elastaseal data sheetElastaseal data sheet
Elastaseal data sheet
 
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENTCERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
 
Residential microfiltration catalogue
Residential microfiltration catalogueResidential microfiltration catalogue
Residential microfiltration catalogue
 
Flexeon mktf 115-res_ro_pb_hr_locked
Flexeon mktf 115-res_ro_pb_hr_lockedFlexeon mktf 115-res_ro_pb_hr_locked
Flexeon mktf 115-res_ro_pb_hr_locked
 
Residential microfiltration catalogue
Residential microfiltration catalogueResidential microfiltration catalogue
Residential microfiltration catalogue
 

More from Depuratori Acqua Osmosi Inversa Addolcitori Sinergroup

More from Depuratori Acqua Osmosi Inversa Addolcitori Sinergroup (20)

Ultrafiltration catalog
Ultrafiltration catalogUltrafiltration catalog
Ultrafiltration catalog
 
Ultrafiltrazione catalogo
Ultrafiltrazione catalogoUltrafiltrazione catalogo
Ultrafiltrazione catalogo
 
Tester and rapid kit for analysis catalog
Tester and rapid kit for analysis catalogTester and rapid kit for analysis catalog
Tester and rapid kit for analysis catalog
 
Tester e Kit rapidi per analisi catalogo
Tester e Kit rapidi per analisi catalogoTester e Kit rapidi per analisi catalogo
Tester e Kit rapidi per analisi catalogo
 
Control and dosing instruments catalog
Control and dosing instruments catalogControl and dosing instruments catalog
Control and dosing instruments catalog
 
Strumenti di controllo e dosaggio catalogo
Strumenti di controllo e dosaggio catalogoStrumenti di controllo e dosaggio catalogo
Strumenti di controllo e dosaggio catalogo
 
UV System For Air catalog
UV System For Air catalogUV System For Air catalog
UV System For Air catalog
 
Sistemi UV per aria catalogo
Sistemi UV per aria catalogoSistemi UV per aria catalogo
Sistemi UV per aria catalogo
 
UV Systems For Everpure Cartridges catalog
UV Systems For Everpure Cartridges catalogUV Systems For Everpure Cartridges catalog
UV Systems For Everpure Cartridges catalog
 
Sistemi UV per cartucce Everpure catalogo
Sistemi UV per cartucce Everpure catalogoSistemi UV per cartucce Everpure catalogo
Sistemi UV per cartucce Everpure catalogo
 
UV Systems catalog
UV Systems catalogUV Systems catalog
UV Systems catalog
 
Sistemi UV catalogo
Sistemi UV catalogoSistemi UV catalogo
Sistemi UV catalogo
 
Faucets columns fonts catalog
Faucets columns fonts catalogFaucets columns fonts catalog
Faucets columns fonts catalog
 
Rubinetteria e colonnine catalogo
Rubinetteria e colonnine catalogoRubinetteria e colonnine catalogo
Rubinetteria e colonnine catalogo
 
Water Coolers catalog
Water Coolers catalogWater Coolers catalog
Water Coolers catalog
 
Refrigeratori acqua catalogo
Refrigeratori acqua catalogoRefrigeratori acqua catalogo
Refrigeratori acqua catalogo
 
Resins and filtering medias catalog
Resins and filtering medias catalogResins and filtering medias catalog
Resins and filtering medias catalog
 
Resine e masse filtranti catalogo
Resine e masse filtranti catalogoResine e masse filtranti catalogo
Resine e masse filtranti catalogo
 
Fittings - Brass fit tubing and valves catalog
Fittings - Brass fit tubing and valves catalogFittings - Brass fit tubing and valves catalog
Fittings - Brass fit tubing and valves catalog
 
Raccordi, tubi e valvole in ottone catalogo
Raccordi, tubi e valvole in ottone catalogoRaccordi, tubi e valvole in ottone catalogo
Raccordi, tubi e valvole in ottone catalogo
 

Recently uploaded

Tech Startup Growth Hacking 101 - Basics on Growth Marketing
Tech Startup Growth Hacking 101  - Basics on Growth MarketingTech Startup Growth Hacking 101  - Basics on Growth Marketing
Tech Startup Growth Hacking 101 - Basics on Growth MarketingShawn Pang
 
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCRsoniya singh
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessAggregage
 
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | DelhiFULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | DelhiMalviyaNagarCallGirl
 
Marketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet CreationsMarketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet Creationsnakalysalcedo61
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewasmakika9823
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Timedelhimodelshub1
 
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCRsoniya singh
 
M.C Lodges -- Guest House in Jhang.
M.C Lodges --  Guest House in Jhang.M.C Lodges --  Guest House in Jhang.
M.C Lodges -- Guest House in Jhang.Aaiza Hassan
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfmuskan1121w
 
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurVIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurSuhani Kapoor
 
NewBase 22 April 2024 Energy News issue - 1718 by Khaled Al Awadi (AutoRe...
NewBase  22 April  2024  Energy News issue - 1718 by Khaled Al Awadi  (AutoRe...NewBase  22 April  2024  Energy News issue - 1718 by Khaled Al Awadi  (AutoRe...
NewBase 22 April 2024 Energy News issue - 1718 by Khaled Al Awadi (AutoRe...Khaled Al Awadi
 
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story
 Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story
 AbridgedLean: From Theory to Practice — One City’s (and Library’s) Lean Story
 Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story
 AbridgedKaiNexus
 
Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...lizamodels9
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCRsoniya singh
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst SummitHolger Mueller
 

Recently uploaded (20)

Tech Startup Growth Hacking 101 - Basics on Growth Marketing
Tech Startup Growth Hacking 101  - Basics on Growth MarketingTech Startup Growth Hacking 101  - Basics on Growth Marketing
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
 
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for Success
 
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | DelhiFULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
 
Marketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet CreationsMarketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet Creations
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Time
 
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
 
M.C Lodges -- Guest House in Jhang.
M.C Lodges --  Guest House in Jhang.M.C Lodges --  Guest House in Jhang.
M.C Lodges -- Guest House in Jhang.
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdf
 
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurVIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
 
NewBase 22 April 2024 Energy News issue - 1718 by Khaled Al Awadi (AutoRe...
NewBase  22 April  2024  Energy News issue - 1718 by Khaled Al Awadi  (AutoRe...NewBase  22 April  2024  Energy News issue - 1718 by Khaled Al Awadi  (AutoRe...
NewBase 22 April 2024 Energy News issue - 1718 by Khaled Al Awadi (AutoRe...
 
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story
 Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story
 AbridgedLean: From Theory to Practice — One City’s (and Library’s) Lean Story
 Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story
 Abridged
 
KestrelPro Flyer Japan IT Week 2024 (English)
KestrelPro Flyer Japan IT Week 2024 (English)KestrelPro Flyer Japan IT Week 2024 (English)
KestrelPro Flyer Japan IT Week 2024 (English)
 
Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❀8860477959 Escorts 100% Genuine Servi...
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
Best Practices for Implementing an External Recruiting Partnership
Best Practices for Implementing an External Recruiting PartnershipBest Practices for Implementing an External Recruiting Partnership
Best Practices for Implementing an External Recruiting Partnership
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst Summit
 

Membranes Catalog

  • 3. Membranes Code: 090001 Filmtec RO membranes TFC TW30 1812 - 50, 75, 100 GPD (25) Variants Code Description 090001-01 Filmtec RO membrane TFC TW30 1812 - 50 GPD (25) 090001-02 Filmtec RO membrane TFC TW30 1812 - 75 GPD (25) 090001-03 Filmtec RO membrane TFC TW30 1812 - 100 GPD (25) Code: 090005 Greenfilter RO membranes TFC 1812/2012/3012/3013 - 50, 75, 100, 150, 180, 300, 400 GPD Variants Code Description 090005-50 Greenfilter RO membrane TFC 1812 - 50 GPD (25) 090005-75 Greenfilter RO membrane TFC 1812 - 75 GPD (25) 090005-100 Greenfilter RO membrane TFC 1812 - 100 GPD (25) 090005-180 Greenfilter RO membrane TFC 2012 - 180 GPD (25) 090005-300 Greenfilter RO membrane TFC 3012 - 300 GPD (1) 090005-400 Greenfilter RO membrane TFC 3013 - 400 GPD (1) Definition Reverse osmosis process is based on nature and has been used for more than 30 years. These semi- permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 ”m. 2. Polysulfone 45 ”m . 3. Non woven fabric polyester 100 ”m. Spacer: EPDM 16 September 2022 3/23
  • 4. SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090005-50 Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090005-75 Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 100 GPD Cod. 090005-100 Active surface: 0,46mÂČ(5ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 150 GPD Cod. 090005-150 Active surface: x,xxmÂČ(xftÂČ) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts rejection(N2) 97,5% * Recovery del 15% Membrane 180 GPD Cod. 090005-180 Active surface: x,xxmÂČ(xftÂČ) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts rejection(N2) 93% * Recovery del 15% Membrane 300 GPD Cod. 090005-300 Active surface: x,xxmÂČ(xftÂČ) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts rejection(N2) 95% * Recovery del 15% Membrane 400 GPD Cod. 090005-400 Active surface: x,xxmÂČ(xftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts rejection(N2) 95% * Recovery del 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ÂșC (77ÂșF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ÂșC (113ÂșF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine toleranceÂč <0,1 ppm OPERATING LIMITS OF 150, 180, 300,400 GPD * Max. temperature 45ÂșC (113ÂșF) * Max. pressure 8,6 bar (125 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * Free Chlorine toleranceÂč <0,1 ppm ÂčUnder certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION ‱ All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite and propylene glycol to prevent biological growth in short-term storage and transport. 16 September 2022 4/23
  • 5. ‱ It is suggested that firs hour of pure water to be rejected. ‱ Keep elements moist after initial wetting. ‱ To prevent biological growth during prolonged system shutdown, it is recommended that membrane elements be immersed in a preservative solution. ‱ The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. ‱ The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. ‱ Use just glycerine as a lubricant if is needed. ‱ The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Code: 090018 Greenfilter RO encapsulated membranes TFC 50, 75, 100 GPD Variants Code Description 090018-01 Greenfilter RO encapsulated membrane TFC 50 GPD 090018-02 Greenfilter RO encapsulated membrane TFC 75 GPD 090018-03 Greenfilter RO encapsulated membrane TFC 75 GPD Filmtec 090018-04 Greenfilter RO encapsulated membrane TFC 100 GPD High efficiency, disposable encapsulate membranes. Change complete of vessel + membrane for maximum hygiene! These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 ”m. 2. Polysulfone 45 ”m . 3. Non woven fabric polyester 100 ”m. Spacer: EPDM SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090018-01 Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090018-02 Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090018-03 FilmtecÂź Active surface: 0,37mÂČ(4ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% 16 September 2022 5/23
  • 6. Membrane 100 GPD Cod. 090018-04 Active surface: 0,46mÂČ(5ftÂČ) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ÂșC (77ÂșF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% Connections: * Inlet water: O.D. stem Ø 3/8" * Outlet permeate: O.D. stem Ø 1/4" * Drain: O.D. stem Ø 1/4" OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ÂșC (113ÂșF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine toleranceÂč <0,1 ppm ÂčUnder certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION ‱ It is suggested that firs hour of pure water to be rejected. ‱ Keep elements moist after initial wetting. ‱ The membrane has a certain short-term resistance against chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. ‱ The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. ‱ Use just glycerine as a lubricant if is needed. ‱ The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Note: The polluting agents removed or reduced by this system are not necessarily in your water. Code: 090017 Ionicore USmotic RO membranes TFC 2012 - 50, 75, 100, 150, 180 GPD (25) Features Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day) Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day) Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day) 16 September 2022 6/23
  • 7. Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day) Permeate flow rate (+/-20%) 180: 180 Gpd (681 lt./day) Minimum salt rejection: 96% Stabilized salt rejection: 98% Operating pressure test: 65 PSI TDS feed test: Tap Water (from 450 to 700 ppm) Water temperature test: 77°F. (25°C.) Recovery test: 15% Max. operating pressure: 125 - 300 PSIG Max. feed SDI: 5 (15 min) Max. feed flow rate: 2 gal./min. (7,57 lt./min.) Chlorine tolerance: <0.1 ppm Max. operating temperature: 113°F. (45°C.) Ph range: 2-11 Max. feed water turbidity: 1 NTU Membrane style: Dry Variants Code Description 090017-050 Ionicore USmotic RO membrane TFC 2012 - 50GPD (25) 090017-075 Ionicore USmotic RO membrane TFC 2012 - 75GPD (25) 090017-100 Ionicore USmotic RO membrane TFC 2012 - 100GPD (25) 090017-150 Ionicore USmotic RO membrane TFC 2012 - 150GPD (25) 090017-180 Ionicore RO USmotic membrane TFC 2012 - 180GPD (25) The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * High Rejection & Flow Rate * Made in the USA * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 ”m. 2. Polysulfone 40 ”m. 3. Non woven fabric polyester 120 ”m. Spacer: EPDM Active surface: 50 GPD 0.35 m2 (3.8 sq. ft) 75 GPD 0.35 m2 (3.8 sq. ft) 100 GPD 0.52 m2 (5.6 sq. ft) 150 GPD 0.58 m2 (6.2 sq. ft) 180 GPD 0.64 m2 (6.9 sq. ft) TFC Nominal Rejection Characteristics: 16 September 2022 7/23
  • 8. Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months. 16 September 2022 8/23
  • 9. Code: 090026 Ionicore Keypra RO membranes TFC 1812/2012 - 50, 75, 100, 150, 200 GPD (25) Features Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day) Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day) Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day) Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day) Permeate flow rate (+/-20%) 200: 200 Gpd (757 lt./day) Minimum salt rejection: 97% Stabilized salt rejection: 98% Operating pressure test: 60 PSI TDS feed test: Tap Water (from 250 to 700 ppm) Water temperature test: 77°F. (25°C.) Recovery test: 15% Max. operating pressure: 125 PSIG / 0.86 MPa (8,6 Bar) Max. feed SDI: 5 (15 min) Max. feed flow rate: 2 gal./min. (7,57 lt./min.) Chlorine tolerance: <0.1 ppm Max. operating temperature: 113°F. (45°C.) Ph range: 2-11 Max. feed water turbidity: 1 NTU Membrane style: Dry Variants Code Description 090026-050 Ionicore Keypra RO membrane TFC 1812 - 50GPD (25) 090026-075 Ionicore Keypra RO membrane TFC 1812 - 75GPD (25) 090026-100 Ionicore Keypra RO membrane TFC 2012 - 100GPD (25) 090026-150 Ionicore Keypra RO membrane TFC 2012 - 150GPD (25) 090026-200 Ionicore Keypra RO membrane TFC 2012 - 200GPD (25) The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 200 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * High Rejection & Flow Rate * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm 16 September 2022 9/23
  • 10. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 ”m. 2. Polysulfone 40 ”m. 3. Non woven fabric polyester 120 ”m. Spacer: EPDM Active surface: 50 GPD 0.37 m2 (3.9 sq. ft) 75 GPD 0.40 m2 (4.3 sq. ft) 100 GPD 0.40 m2 (4.3 sq. ft) 150 GPD 0.58 m2 (6.2 sq. ft) 200 GPD 0.77 m2 (8.2 sq. ft) TFC Nominal Rejection Characteristics: Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for 16 September 2022 10/23
  • 11. that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months. Code: 090025 Ionicore Keypra RO membranes TFC 3012/3013 - 300, 400 GPD (9) Features Permeate flow rate (+/-20%) 300: 300 Gpd (1.135 lt./day) Permeate flow rate (+/-20%) 400: 400 Gpd (1.514 lt./day) Minimum salt rejection: 97% Stabilized salt rejection: 97% Operating pressure test: 100 PSI TDS feed test: 250 ppm Water temperature test: 77°F. (25°C.) Recovery test: 15% Max. operating pressure: 300 PSIG / 2.06 MPa (20,6 Bar) Max. feed SDI: 5 (15 min) Max. feed flow rate: 2 gal./min. (7,57 lt./min.) Chlorine tolerance: <0.1 ppm Max. operating temperature: 113°F. (45°C.) Ph range: 3-10 Max. feed water turbidity: 1 NTU Membrane style: Dry Variants Code Description 090025-300 Ionicore Keypra RO membrane TFC 3012 - 300GPD (9) 090025-400 Ionicore Keypra RO membrane TFC 3013 - 400GPD (9) The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 400 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * High Rejection & Flow Rate * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm 16 September 2022 11/23
  • 12. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 ”m. 2. Polysulfone 40 ”m. 3. Non woven fabric polyester 120 ”m. Spacer: EPDM Active surface: 300 GPD 1.14 m2 (12.3 sq. ft) 400 GPD 1.42 m2 (15.3 sq. ft) TFC Nominal Rejection Characteristics: Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in 16 September 2022 12/23
  • 13. your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months. Code: 090019 Pentair RO encapsulated membranes TLC GRO 36, 50, 75 GPD (16) Variants Code Description 090019-01 Pentair RO encapsulated membrane TLC GRO-36EN GPD (16) 090019-02 Pentair RO encapsulated membrane TLC GRO-50EN GPD (16) 090019-03 Pentair RO encapsulated membrane TLC GRO-75EN GPD (16) GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high quality reverse osmosis water while wasting 3 times less water to the drain. Features * TLC Thin Layer Composite membrane. * 100% dry membrane maximizing shelf life. * Double the recovery over standard RO elements. * High rejection stability at high input TDS. * Maximal Pressure: 6.90 bar. * Maximal Temperature: 49°C. * pH: 4-11. * Free Chlorine: 0.1 ppm. Connections: * Inlet water: 1/4" Quick Fit.. * Outlet permeate: 1/4" Quick Fit. * Drain: 1/4" Quick Fit. Benefits * 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO) * High performances even under extreme conditions. * Membrane can be stored for a longer period of time. Nominal performance GRO-36EN * Flow* Gpd (Lpd): 36 (136.3); * Rejection: 96%; * Drain flow control (ml./min.): 100. Nominal performance GRO-50EN * Flow* Gpd (Lpd): 50 (189.3); * Rejection: 96%; * Drain flow control (ml./min.): 150. Nominal performance GRO-75EN * Flow* Gpd (Lpd): 75 (283.9); * Rejection:96%; * Drain flow control (ml./min.): 200. 16 September 2022 13/23
  • 14. Nota bene: The data above is based on internal laboratory testing. * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ÂșC, 50% recovery after 24 hours. Individual element flux may vary ± 15%. The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against NSF/ANSI Standard 58 for materials and structural integrity requirements. Here is the expected amount of water saved each year, for a family of 4 people: Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt. Standard RO membrane: 17’520 lt. of rejected water. GRO membrane: 4’380 lt. of rejected water. The use of GRO membranes allows a saving of about 13’000 lt. of water per year. Code: 090012 Pentair RO membranes TLC 50, 75, 100 GPD (25) Variants Code Description 090012-050 Pentair RO membrane TLC - 50GPD (25) 090012-075 Pentair RO membrane TLC - 75GPD (25) 090012-100 Pentair RO membrane TLC - 100GPD (25) TLCℱ RESIDENTIAL RO MEMBRANES The best way to assess the overall filtration quality of a RO system is made by measuring the rejection, which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the rejection, the better the membrane performs. The recovery of a RO system represents the quantity of permeate produced compared with the quantity of concentrate rejected to the drain. The higher the recovery, the lower the rejection is. RO MEMBRANE’S CONSTRUCTION The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around a perforated central tube. Purified water passes through the membrane and is collected in the permeate collection material while rejected impurities stay in the feed channel spacer. TLCℱ RANGE TLCℱ (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any types of needs from the customer. Dimensions of these membranes are standard; they will fit into any reverse osmosis systems from the market. FEATURES ‱ TLC Thin Layer Composite membrane ‱ 100% dry membrane maximizing shelf life ‱ High rejection stability at high input TDS ‱ Standard dimensions: can be fitted in any RO systems ‱ Maximal Pressure: 6.90 bar ‱ Maximal Temperature: 49°C ‱ pH: 4-11 ‱ Hardness: 17°F ‱ Free Chlorine: 0.1 ppm 16 September 2022 14/23
  • 15. ‱ Rejection*: 98% NOMINAL PERFORMANCE TLC-50 ‱ Flow* Gpd (Lpd): 50 (189.3) NOMINAL PERFORMANCE TLC-75 ‱ Flow* Gpd (Lpd): 75 (283.9) NOMINAL PERFORMANCE TLC-100 ‱ Flow* Gpd (Lpd): 100 (378.5) * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ÂșC, 15% recovery after 24 hours. Individual element flux may vary ± 15%. BENEFITS OF TLCℱ MEMBRANES 100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag. We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost endless! HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS Whatever the amount of total dissolved solids from the inlet water, TLCℱ membranes will always give optimal performances. When compared with a membrane from competition, we can clearly see that Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at 1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**. **Results obtained from internal testing (more testing results are available upon request) NSF CERTIFIED Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will save time and money during the NSF certification process of the complete RO system by the OEM. NSF COMPONENT The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS IMPORTANT INFORMATION Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC Membranes are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane element performance can be affected by fluctuations in water quality. Code: 090007 AMI RO membranes TFC 1812/3012 100, 150, 300 GPD (25) 16 September 2022 15/23
  • 16. Variants Code Description 090007-100 AMI RO membrane TFC 1812 - 100GPD (25) 090007-150 AMI RO membrane TFC 1812 - 150GPD (25) 090007-300 AMI RO membrane TFC 3012 - 300GPD (25) AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality. Recommended Operating Conditions (50, 75, 100, 150gpd) * Maximum operating pressure: 125 psi (8,61bar) * Maximum feed flow rate: 2 gpm (7,57lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 5 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Minimum brine flow to permeate flow ratio: 4:1 * Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm) * Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm) Note: Salt rejection and performance specifications shown are from internal test data. Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C) feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%. The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits loosely, you may need to wrap a few layers of tape near one end to make a tight fit. Recommended Operating Conditions (300gpd) * Maximum operating pressure: 300 psi (20,68bar) * Maximum feed flow rate: 6 gpm (22,71lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Single Element recovery: 15% * Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm) Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8 and 10% recovery. Element permeate flow may vary ± 15%. Code: 090006 NF90-2012 nanofiltration RO membrane - 180GPD (25) 16 September 2022 16/23
  • 17. Variants Code Description 090006-01 NF90-2012 nanofiltration RO membrane - 180GPD (25) ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide composite membrane elements display an outsdanding salt rejection of more than 97% , superior product water flow , high thermal and pressure durability , wide tolerance of chlorine and PH. SPECIFICATIONS OF PRODUCT Membrane 180GPD Cod. 090006-01 NF90-2012 NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD Test condition Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm * Recovery: 15% Operating limits Max. temperature 40ÂșC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) * Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm Caution Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to stabilized Code: 090002 Housings 2,5" for reverse osmosis membrane 1812, 2012 - 50, 75, 100, 150, 180 GPD Variants Code Description 090002-06 Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure 1/8" (20) (WE DON'T KNOW THE NEXT AVAILABILITY DA 090002-04 Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure double o-ring 1/8" (40) 090002-03 1812, 2012 Housing Wrench for cod. 090002-04 With double o-ring. Code: 090021 Vessel for reverse osmosis membrane 3012 - 300GPD 16 September 2022 17/23
  • 18. Connections * Inlet: 1/4" * Outlet/Drain: 1/8" Code: 090027 Vessel for reverse osmosis membrane 3012 - 300GPD quick fittings connections clips Variants Code Description 090027-01 Vessel for reverse osmosis membrane 3012 - 300GPD quick fittings connections clips The vessels are reverse osmosis membranes containers for domestic or industrial use, they can be used with all the 3012 membranes series regardless model and brand, membranes with 300 gallons per day (GPD) production performance. They are usually used inside reverse osmosis systems and water purifiers with direct production or tank. The vessel is supplied with quick fittings for a simple and quick installation with quick fitting clips. Technical features: - Material: polypropylene; - Color: white; - Maximum operating temperature: 45 ° C (113 ° F) - Maximum operating pressure: 12 bar (174 psi) - Connections: Inlet 3/8 "- Outlet / Drain: 1/4"; - Compatible membranes: 3012. ATTENTION Do not exceed indicated pressures in the technical specifications as the thrust pressure on the screwed cap generates a considerable force. Code: 090015 Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips Variants Code Description 090015-01 Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips 090015-02 3013 vessel wrench for cod. 090015-01 16 September 2022 18/23
  • 19. Connections * Inlet: 3/8" * Outlet/Drain: 1/4" Code: 090022 Vessel for reverse osmosis membrane 3013 - 400GPD Connections * Inlet: 1/4" * Outlet/Drain: 1/8" Code: 090023 Ionicore RO membranes TFC LP2521, LP2540, LP4040 Medium pressure Features Permeate flow rate (+/-20%) LP2521: 300 gal./giorno (1.135 lt./giorno) Permeate flow rate (+/-20%) LP2540: 750 gal./giorno (2.839 lt./giorno) Permeate flow rate (+/-20%) LP4040: 2.500 gal./giorno (9.463 lt./giorno) Minimum salt rejection: 98% Stabilized salt rejection: 99% Operating pressure test: 150 PSI (10,3 Bar) TDS feed test: 1500 ppm Water temperature test: 77°F. (25°C.) Recovery test: 15% Ph test: 7,5 Max. operating pressure: 600 PSIG / 4.23 MPa (42,3 Bar) Max. feed SDI: 5 (15 min) Max. feed flow rate: 16 gal./min. (60,55 lt./min.) Chlorine tolerance: <0.1 ppm Max. operating temperature: 113°F. (45°C.) Ph range: 3-10 Variants Code Description 090023-02 Ionicore RO membrane TFC LP2521 Medium pressure 090023-03 Ionicore RO membrane TFC LP2540 Medium pressure 090023-04 Ionicore RO membrane TFC LP4040 Medium pressure The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to 16 September 2022 19/23
  • 20. remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available with different flow rates. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. m174/2004 (Italian Ministerial Decree).The membrane remove up to 99% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * ISO 9001:2008 Certified * Max. inlet Hardness: 5°F. (50ppm) * Max. Free Chlorine: 0.1 ppm Active surface: TFC LP2521: 1,3 m2 (14 sq. ft) TFC LP2540: 2,6 m2 (28 sq. ft) TFC LP4040: 8,4 m2 (90 sq. ft) TFC Nominal Rejection Characteristics: Calcium: 99% Sodium: 99% Magnesium: 99% Potassium: 98% Manganese: 99% Iron: 99% Aluminum: 99% Copper: 99% Nickel: 99% Cadmium: 99% Silver: 99% Zinc: 99% Mercury: 99% Radioactivity: 98-99,3% Chloride: 95-97% Ammonium: 88-97% Bromide: 94-96% Phosphate: >99% Chromate: 90-98% Cyanide: 90-97% Sulfate: 85-99% Thiosulfate: 96-99% Silicate: 95-97% Silica: 80-98% Nitrate: 93-96% Boron: 80-86% Borate: 35-70% Fluoride: 94-96% Polyphosphate: >99% Orthophosphate: 98-99% Chromate: 90-98% Virus and Bacteria:100% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. 16 September 2022 20/23
  • 21. Code: 090013 Greenfilter RO membranes TFC LP2514, LP2521, LP2540, LP4040 Medium pressure Variants Code Description 090013-04 Greenfilter RO membrane TFC LP2514 Medium pressure 090013-01 Greenfilter RO membrane TFC LP2521 Medium pressure 090013-02 Greenfilter RO membrane TFC LP2540 Medium pressure 090013-03 Greenfilter RO membrane TFC LP4040 Medium pressure Code: 090024 Ionicore housings 2,5" and 4" for reverse osmosis membranes 2514, 2521, 2540, 4040x1 - 300psi SS304, FRP Variants Code Description 090024-01 Ionicore housing 2,5" for R.O. membrane 2514x1 - 300psi SS304 090024-02 Ionicore housing 2,5" for R.O. membrane 2521x1 - 300psi SS304 090024-03 Ionicore housing 2,5" for R.O. membrane 2540x1 - 300psi SS304 090024-04 Ionicore housing 4" for R.O. membrane 4040x1 - 300psi SS304 090024-10 Ionicore housing 2,5" for R.O. membrane 2514x1 - 300psi FRP 090024-11 Ionicore housing 2,5" for R.O. membrane 2521x1 - 300psi FRP 090024-12 Ionicore housing 2,5" for R.O. membrane 2540x1 - 300psi FRP 090024-13 Ionicore housing 4" for R.O. membrane 4040x1 - 300psi FRP 16 September 2022 21/23
  • 22. Code: 090020 Housing 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter Variants Code Description 090020-02 Housing 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02 Features: * Made of fiber reinforced polyester. * Front connection, permeate the collection at both ends. * Close by blocking half-length AISI-304 easy membrane replacement. * EPDM seals. ABS collector plugs. * Compatible with standard 4 "membranes. * Support brackets included. Connections: * Inlet: 1/2" BSP F. * Outlet/Drain: 3/4" BSP F Technical features: * Pressure: 21 kg/cm2, 21 bar (300 psi) * Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi) * Max. temperature: 49°C (120.2°F) * Min. temperature: -10°C (14°F) * pH range, continuous operation: 3-11 * pH range, short-term cleaning: 2-12 (max 30 min.) * Weight: 6 kg 16 September 2022 22/23
  • 23. Powered by TCPDF (www.tcpdf.org)