SlideShare a Scribd company logo
1 of 18
Download to read offline
INDEX
Membranes............................................................................................................................................................. 3
Membranes
Code: 090001
Filmtec membrane TFC TW30 1812 - 50, 75, 100 GPD (25)
Variants
Code Description
090001-01 Filmtec membrane TFC TW30 1812 - 50 GPD (25)
090001-02 Filmtec membrane TFC TW30 1812 - 75 GPD (25)
090001-03 Filmtec membrane TFC TW30 1812 - 100 GPD (25)
Code: 090005
Greenfilter membrane TFC 1812/2012/3012/3013 - 50, 75, 100,
150, 180, 300, 400 GPD
Variants
Code Description
090005-50 Greenfilter membrane TFC 1812 - 50 GPD (25)
090005-75 Greenfilter membrane TFC 1812 - 75 GPD (25)
090005-100 Greenfilter membrane TFC 1812 - 100 GPD (25)
090005-150 Greenfilter membrane TFC 1812 - 150 GPD (25)
090005-180 Greenfilter membrane TFC 2012 - 180 GPD (25)
090005-300 Greenfilter membrane TFC 3012 - 300 GPD (1)
090005-400 Greenfilter membrane TFC 3013 - 400 GPD (1)
Definition
Reverse osmosis process is based on nature and has been used for more than 30 years. These semi-
permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the
process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.3 µm.
2. Polysulfone 45 µm .
3. Non woven fabric polyester 100 µm.
13 October 2017 3/18
Spacer: EPDM
SPECIFICATIONS OF PRODUCT
Membrane 50 GPD Cod. 090005-50
Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 75 GPD Cod. 090005-75
Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 100 GPD Cod. 090005-100
Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 150 GPD Cod. 090005-150
Active surface: x,xxm²(xft²) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts
rejection(N2) 97,5% * Recovery del 15%
Membrane 180 GPD Cod. 090005-180
Active surface: x,xxm²(xft²) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts
rejection(N2) 93% * Recovery del 15%
Membrane 300 GPD Cod. 090005-300
Active surface: x,xxm²(xft²) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts
rejection(N2) 95% * Recovery del 15%
Membrane 400 GPD Cod. 090005-400
Active surface: x,xxm²(xft²) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts
rejection(N2) 95% * Recovery del 15%
(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF),
15% recovery
and specified applied pressure. Permeated flows for individual elements may vary +/- 15%.
(N2) Minimum SALT rejection is 95%
OPERATING LIMITS OF 50, 75, 100 GPD
* Max. temperature 45ºC (113ºF)
* Max. pressure 21 bar (300 psi)
* Max. P for element 1 bar (15 psi)
* Max feed flow rate 7,6 lpm (2.0 gpm)
* pH range, continuous operation 3 - 10
* pH range, short-term cleaning (30 min) 2 - 11
* Max. Feed SDI 5
* Free Chlorine tolerance¹ <0,1 ppm
OPERATING LIMITS OF 150, 180, 300,400 GPD
* Max. temperature 45ºC (113ºF)
* Max. pressure 8,6 bar (125 psi)
* Max feed flow rate 7,6 lpm (2.0 gpm)
* pH range, continuous operation 3 - 10
* Free Chlorine tolerance¹ <0,1 ppm
¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature
membrane failure.
We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We
recommend replacing it every 24 months max.
GENERAL INFORMATION
13 October 2017 4/18
• All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite
and propylene glycol to prevent biological growth in short-term storage and transport.
• It is suggested that firs hour of pure water to be rejected.
• Keep elements moist after initial wetting.
• To prevent biological growth during prolonged system shutdown, it is recommended that membrane
elements be immersed in a preservative solution.
• The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous
exposure, however, may damage the membrane and should be avoided.
• The customer is fully responsible for effects of incompatible chemicals and lubricants on elements.
• Use just glycerine as a lubricant if is needed.
• The use of this product in and of itself does not necessarily guarantee the removal of cysts and
pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design
and on the operation and maintenance of the system.
Code: 090018
Greenfilter encapsulated membranes TFC 50, 75, 100 GPD
Variants
Code Description
090018-01 Greenfilter encapsulated membrane TFC 50 GPD
090018-02 Greenfilter encapsulated membrane TFC 75 GPD
090018-03 Greenfilter encapsulated membrane TFC 75 GPD Filmtec
090018-04 Greenfilter encapsulated membrane TFC 100 GPD
High efficiency, disposable encapsulate membranes.
Change complete of vessel + membrane for maximum hygiene!
These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive
salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.3 µm.
2. Polysulfone 45 µm .
3. Non woven fabric polyester 100 µm.
Spacer: EPDM
SPECIFICATIONS OF PRODUCT
Membrane 50 GPD Cod. 090018-01
Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 75 GPD Cod. 090018-02
Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 75 GPD Cod. 090018-03 Filmtec®
13 October 2017 5/18
Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts
rejection(N2) 97% * Recovery 15%
Membrane 100 GPD Cod. 090018-04
Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts
rejection(N2) 97% * Recovery 15%
(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF),
15% recovery
and specified applied pressure. Permeated flows for individual elements may vary +/- 15%.
(N2) Minimum SALT rejection is 95%
Connections:
* Inlet water: O.D. stem Ø 3/8"
* Outlet permeate: O.D. stem Ø 1/4"
* Drain: O.D. stem Ø 1/4"
OPERATING LIMITS OF 50, 75, 100 GPD
* Max. temperature 45ºC (113ºF)
* Max. pressure 21 bar (300 psi)
* Max. P for element 1 bar (15 psi)
* Max feed flow rate 7,6 lpm (2.0 gpm)
* pH range, continuous operation 3 - 10
* pH range, short-term cleaning (30 min) 2 - 11
* Max. Feed SDI 5
* Free Chlorine tolerance¹ <0,1 ppm
¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature
membrane failure.
We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We
recommend replacing it every 24 months max.
GENERAL INFORMATION
• It is suggested that firs hour of pure water to be rejected.
• Keep elements moist after initial wetting.
• The membrane has a certain short-term resistance against chlorine (hypochlorite). Continuous exposure,
however, may damage the membrane and should be avoided.
• The customer is fully responsible for effects of incompatible chemicals and lubricants on elements.
• Use just glycerine as a lubricant if is needed.
• The use of this product in and of itself does not necessarily guarantee the removal of cysts and
pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design
and on the operation and maintenance of the system.
Note: The polluting agents removed or reduced by this system are not necessarily in your water.
Code: 090017
Ionicore USmotic membrane TFC 2012 - 50, 75, 100, 150, 180
GPD (25)
Features
13 October 2017 6/18
Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day)
Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day)
Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day)
Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day)
Permeate flow rate (+/-20%) 180: 180 Gpd (681 lt./day)
Minimum salt rejection: 96%
Stabilized salt rejection: 98%
Operating pressure test: 65 PSI
TDS feed test: Tap Water (from 450 to 700 ppm)
Water temperature test: 77°F. (25°C.)
Recovery test: 15%
Max. operating pressure: 125 PSIG / 0.86 MPa (8,6 Bar)
Max. feed SDI: 5 (15 min)
Max. feed flow rate: 2 gal./min. (7,57 lt./min.)
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 2-11
Max. feed water turbidity: 1 NTU
Membrane style: Dry
Variants
Code Description
090017-050 Ionicore USmotic membrane TFC 2012 - 50 GPD (25)
090017-075 Ionicore USmotic membrane TFC 2012 - 75GPD (25)
090017-100 Ionicore USmotic membrane TFC 2012 - 100GPD (25)
090017-150 Ionicore USmotic membrane TFC 2012 - 150GPD (25)
090017-180 Ionicore USmotic membrane TFC 2012 - 180GPD (25)
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents
the better water filtration technique, because is not a simply unwanted substances reduction but is able to
remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally
made of polyamide (PA).
These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons
per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the
reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M.
174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS),
delivering healthier and safer drinking water.
Features:
* High Rejection & Flow Rate
* Made in the USA
* ISO 9001:2008 Certified
* Standard dimensions: can be fitted in any RO systems
* Max. inlet Hardness: 25°F. (250ppm)
* Max. Free Chlorine: 0.1 ppm
Type of membrane: Spiral wound
Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.2 µm.
2. Polysulfone 40 µm.
3. Non woven fabric polyester 120 µm.
Spacer: EPDM
Active surface:
50 GPD 0.35 m2 (3.8 sq. ft)
75 GPD 0.35 m2 (3.8 sq. ft)
100 GPD 0.52 m2 (5.6 sq. ft)
150 GPD 0.58 m2 (6.2 sq. ft)
13 October 2017 7/18
180 GPD 0.64 m2 (6.9 sq. ft)
TFC Nominal Rejection Characteristics:
Calcium: 93-98%
Sodium: 92-98%
Magnesium: 93-98%
Potassium: 92-96%
Manganese: 96-98%
Iron: 96-98%
Aluminum: 96-98%
Copper: 96-98%
Nickel: 96-98%
Cadmium: 93-97%
Silver: 93-96%
Zinc: 96-98%
Mercury: 94-97%
Hardness Ca & Mg: 93-97%
Radioactivity: 93-97%
Chloride: 92-95%
Ammonium: 80-90%
Bromide: 90-95%
Phosphate: 95-98%
Chromate: 85-95%
Cyanide: 85-95%
Sulfate: 96-98%
Thiosulfate: 96-98%
Silicate: 92-95%
Silica: 80-90%
Nitrate: 90-95%
Boron: 50-70%
Borate: 30-50%
Fluoride: 92-95%
Polyphosphate: 96-98%
Orthophosphate: 96-98%
Chromate: 85-95%
Virus and Bacteria: 99% +
Lead: 95-98%
The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the
feed water.
WARNING
The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water)
and it works only if it's installed on water complies with the law, municipal potable water or well water if
previously made drinkable with adequate and effective systems, preventively studied and personalized for
that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown
quality without adequate disinfection before and after the system. All systems must be preserved according
to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in
your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.
13 October 2017 8/18
Code: 090019
Pentair GRO encapsulated membranes TLC 36, 50, 75 GPD (16)
Variants
Code Description
090019-01 Pentair GRO-36EN GPD encapsulated membranes
090019-02 Pentair GRO-50EN GPD encapsulated membranes
090019-03 Pentair GRO-75EN GPD encapsulated membranes
GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high
quality reverse osmosis water while wasting 3 times less water to the drain.
Features
* TLC Thin Layer Composite membrane
* 100% dry membrane maximizing shelf life
* Double the recovery over standard RO elements
* High rejection stability at high input TDS
* Maximal Pressure: 6.90 bar
* Maximal Temperature: 49°C
* pH: 4-11
* Free Chlorine: 0.1 ppm
Connections:
* Inlet water: 1/4" Quick Fit
* Outlet permeate: 1/4" Quick Fit
* Drain: 1/4" Quick Fit
Benefits
* 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO )
* High performances even under extreme conditions
* Membrane can be stored for a longer period of time
Nominal performance GRO-36EN
* Flow* Gpd (Lpd): 36 (136.3)
* Rejection: 96%
* Drain flow control (ml./min.): 100
Nominal performance GRO-50EN
* Flow* Gpd (Lpd): 50 (189.3)
* Rejection: 96%
* Drain flow control (ml./min.): 150
Nominal performance GRO-75EN
* Flow* Gpd (Lpd): 75 (283.9)
* Rejection:96%
* Drain flow control (ml./min.): 200
13 October 2017 9/18
Note: The data above is based on internal laboratory testing.
* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 50% recovery after
24 hours. Individual element flux may vary ± 15%.
The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against
NSF/ANSI Standard 58 for materials and structural integrity requirements.
Here is the expected amount of water saved each year, for a family of 4 people:
Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt.
Standard RO membrane: 17’520 lt. of rejected water
GRO membrane: 4’380 lt. of rejected water
The use of GRO membranes allows a saving of about 13’000 lt. of water per year.
Code: 090012
Pentair membrane TLC 50, 75, 100 GPD (25)
Variants
Code Description
090012-050 Pentair membrane TLC - 50GPD (25)
090012-075 Pentair membrane TLC - 75GPD (25)
090012-100 Pentair membrane TLC - 100GPD (25)
TLC™ RESIDENTIAL RO MEMBRANES
The best way to assess the overall filtration quality of a RO system is made by measuring the rejection,
which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the
rejection, the better the membrane performs. The recovery of a RO system represents the quantity of
permeate produced compared with the quantity of concentrate rejected to the drain. The higher the
recovery, the lower the rejection is.
RO MEMBRANE’S CONSTRUCTION
The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around
a perforated central tube. Purified water passes through the membrane and is collected in the permeate
collection material while rejected impurities stay in the feed channel spacer.
TLC™ RANGE
TLC™ (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any
types of needs from the customer. Dimensions of these membranes are standard; they will fit into any
reverse osmosis systems from the market.
FEATURES
• TLC Thin Layer Composite membrane
• 100% dry membrane maximizing shelf life
• High rejection stability at high input TDS
• Standard dimensions: can be fitted in any RO systems
• Maximal Pressure: 6.90 bar
• Maximal Temperature: 49°C
• pH: 4-11
• Hardness: 17°F
• Free Chlorine: 0.1 ppm
13 October 2017 10/18
• Rejection*: 98%
NOMINAL PERFORMANCE TLC-50
• Flow* Gpd (Lpd): 50 (189.3)
NOMINAL PERFORMANCE TLC-75
• Flow* Gpd (Lpd): 75 (283.9)
NOMINAL PERFORMANCE TLC-100
• Flow* Gpd (Lpd): 100 (378.5)
* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 15% recovery after
24 hours. Individual element flux may vary ± 15%.
BENEFITS OF TLC™ MEMBRANES
100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag.
We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can
happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost
endless!
HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS
Whatever the amount of total dissolved solids from the inlet water, TLC™ membranes will always give
optimal performances. When compared with a membrane from competition, we can clearly see that
Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at
1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**.
**Results obtained from internal testing (more testing results are available upon request)
NSF CERTIFIED
Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will
save time and money during the NSF certification process of the complete RO system by the OEM.
NSF COMPONENT
The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material
requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to
standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS
IMPORTANT INFORMATION
Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC
Membranes are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane
element performance can be affected by fluctuations in water quality.
Code: 090007
AMI membrane TFC 1812/3012 100, 150, 300 GPD (25)
13 October 2017 11/18
Variants
Code Description
090007-100 AMI membrane TFC 1812 - 100GPD (25)
090007-150 AMI membrane TFC 1812 - 150GPD (25)
090007-300 AMI membrane TFC 3012 - 300GPD (25)
AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of
thousands of membranes in operation world-wide, we offer these in a large range of both residential and
commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the
past 30 years AMI Membrane elements have earned the reputation of consistent quality.
Recommended Operating Conditions (50, 75, 100, 150gpd)
* Maximum operating pressure: 125 psi (8,61bar)
* Maximum feed flow rate: 2 gpm (7,57lt./min.)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 5
* Chlorine tolerance: <0.1 ppm
* Feed water pH range, Continuous Operation: 2-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Minimum brine flow to permeate flow ratio: 4:1
* Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm)
* Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm)
Note: Salt rejection and performance specifications shown are from internal test data.
Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C)
feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%.
The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits
loosely, you may need to wrap a few layers of tape near one end to make a tight fit.
Recommended Operating Conditions (300gpd)
* Maximum operating pressure: 300 psi (20,68bar)
* Maximum feed flow rate: 6 gpm (22,71lt./min.)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 4
* Chlorine tolerance: <0.1 ppm
* Feed water pH range, Continuous Operation: 2-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Single Element recovery: 15%
* Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm)
Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8
and 10% recovery. Element permeate flow may vary ± 15%.
Code: 090008
AMI nanofiltration membrane NF 1812 - 150, 200 GPD (25)
13 October 2017 12/18
Variants
Code Description
090008-150 AMI nanofiltration membrane NF 1812 - 150GPD (25)
090008-200 AMI nanofiltration membrane NF 1812 - 200GPD (25)
Nanofiltration Membrane Elements: NF5
What is Nanofiltration?
Nanofiltration (NF), in concept and operation, is much the same as reverse osmosis. The key difference is
the degree of removal of monovalent ions such as chlorides. Reverse osmosis removes the monovalent
ions at 98-99% level at 200psi (13,78bar). Nanofiltration membranes’ removal of monovalent ions varies
between 50% to 90% depending on the material and manufacture of the membrane. For this reason, there
is a variety of
Nanofiltration membranes available. Each type is particularly suited to a certain application and may not be
acceptable to a different application.
Nanofiltration membranes (NF membranes) and systems are used for water softening, food and
pharmaceutical applications.
Recommended Operating Conditions
* Maximum operating pressure: 300psi (20,68bar)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 4
* Chlorine tolerance: <1 ppm
* Maximum Pressure Drop: 13psi (0,89bar)
* Feed water pH range, Continuous Operation: 4-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Average Salt Rejection: 50%
* Average Hardness Rejection: +97%
* Dimensions: L-11,75"(29,85cm) I-10,25"(26,03cm) D-3"(7,61cm)
Note: Performance specifications based on 2000 mg/l magnesium sulfate, 70 psi (4.8 bar) applied
pressure, 77ºF (25ºC) feed water temperature and 15% recovery. Element permeate flow may vary
-20%/+30%.
Code: 090006
NF90-2012 nanofiltration membrane - 180 GPD (25)
Variants
Code Description
090006-01 NF90-2012 nanofiltration membrane - 180 GPD (25)
ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide
composite membrane elements display an outsdanding salt rejection of more than 97% , superior product
water flow , high thermal and pressure durability , wide tolerance of chlorine and PH.
SPECIFICATIONS OF PRODUCT
Membrane 180GPD Cod. 090006-01 NF90-2012
NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD
13 October 2017 13/18
Test condition
Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm *
Recovery: 15%
Operating limits
Max. temperature 40ºC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) *
Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm
Caution
Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to
stabilized
Code: 090002
Housings 2,5'' for reverse osmosis membrane 1812, 2012 - 50,
75, 100, 150, 180GPD (25)
Variants
Code Description
090002-02 Housings 2,5'' for reverse osmosis membrane 1812, 2012 low pressure 1/8" (25) - LAST PIECES
090002-05 1812, 2012 Housing Wrench for cod. 090002-02
090002-04 Housings 2,5'' for reverse osmosis membrane 1812, 2012 high pressure doppio o-ring 1/8" (40)
090002-06 Housings 2,5'' for reverse osmosis membrane 1812, 2012 high pressure 1/8" (25)
090002-03 1812, 2012 Housing Wrench for cod. 090002-06
With double o-ring.
Code: 090009
Housings for reverse osmosis membrane 3012 - 300GPD (12)
Connections
* Inlet/Outlet: 1/4"-3/8" * Drain: 1/4 "
13 October 2017 14/18
Code: 090011
Housings for reverse osmosis membrane 3012 - 300GPD
Greenfilter (1)
Connections
* Inlet: 1/8" * Outlet/Drain: 1/8"
Code: 090014
Yarn Home membrane TFC 3013 - 400 GPD (1)
Code: 090015
Vessel for reverse osmosis membrane 3013 - 400GPD quick
fittings connections clips
Connections
* Inlet: 3/8" * Outlet/Drain: 1/4"
13 October 2017 15/18
Code: 090016
Vessel for reverse osmosis membrane 3013 - 400GPD
Connections
* Inlet: 1/4" * Outlet/Drain: 1/8"
Code: 090013
Greenfilter membrane TFC LP2514, LP2521, LP2540, LP4040
Medium pressure
Variants
Code Description
090013-01 Greenfilter membrane TFC LP2521 Medium pressure
090013-02 Greenfilter membrane TFC LP2540 Medium pressure
090013-03 Greenfilter membrane TFC LP4040 Medium pressure
090013-04 Greenfilter membrane TFC LP2514 Medium pressure
Code: 090020
Housings 4" for reverse osmosis membrane 4040x1 - 300psi-
EP Greenfilter
Variants
Code Description
090020-02 Housings 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter
13 October 2017 16/18
Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02
Features:
* Made of fiber reinforced polyester.
* Front connection, permeate the collection at both ends.
* Close by blocking half-length AISI-304 easy membrane replacement.
* EPDM seals. ABS collector plugs.
* Compatible with standard 4 "membranes.
* Support brackets included.
Connections:
* Inlet: 1/2" BSP F.
* Outlet/Drain: 3/4" BSP F
Technical features:
* Pressure: 21 kg/cm2, 21 bar (300 psi)
* Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi)
* Max. temperature: 49°C (120.2°F)
* Min. temperature: -10°C (14°F)
* pH range, continuous operation: 3-11
* pH range, short-term cleaning: 2-12 (max 30 min.)
* Weight: 6 kg
13 October 2017 17/18
Powered by TCPDF (www.tcpdf.org)

More Related Content

What's hot

Cartridge filter catalog - Jon from Snowate
Cartridge filter catalog - Jon from SnowateCartridge filter catalog - Jon from Snowate
Cartridge filter catalog - Jon from Snowatejon sun
 
Dosing pump catalog
Dosing pump catalogDosing pump catalog
Dosing pump catalogjon sun
 
Molecular sieve introduction-Xiangrun
Molecular sieve introduction-XiangrunMolecular sieve introduction-Xiangrun
Molecular sieve introduction-XiangrunJason Zhang
 
Depth Filter flyer - final
Depth Filter flyer - finalDepth Filter flyer - final
Depth Filter flyer - finalDiwaker Lal
 
Oil Technics Ltd: AFFF-LF Fire Fighting Foam
Oil Technics Ltd: AFFF-LF Fire Fighting FoamOil Technics Ltd: AFFF-LF Fire Fighting Foam
Oil Technics Ltd: AFFF-LF Fire Fighting FoamDavid Holmes
 
2014 CIP Summit - Lonza - Buffer Rings
2014 CIP Summit - Lonza - Buffer Rings2014 CIP Summit - Lonza - Buffer Rings
2014 CIP Summit - Lonza - Buffer RingsAndrew Harris
 
Abdos Cataloge International
Abdos Cataloge InternationalAbdos Cataloge International
Abdos Cataloge InternationalShailendra Yadav
 
Article Contamination Of Insufflators August 2009
Article   Contamination Of Insufflators August 2009Article   Contamination Of Insufflators August 2009
Article Contamination Of Insufflators August 2009cem50
 
Genie supreme 120 membrane seperator datasheet
Genie supreme 120 membrane seperator datasheetGenie supreme 120 membrane seperator datasheet
Genie supreme 120 membrane seperator datasheeta1-cbiss
 

What's hot (20)

13/10/2017 Sinergroup - In line filters
13/10/2017 Sinergroup - In line filters13/10/2017 Sinergroup - In line filters
13/10/2017 Sinergroup - In line filters
 
Cartridge filter catalog - Jon from Snowate
Cartridge filter catalog - Jon from SnowateCartridge filter catalog - Jon from Snowate
Cartridge filter catalog - Jon from Snowate
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Dosing pump catalog
Dosing pump catalogDosing pump catalog
Dosing pump catalog
 
Molecular sieve introduction-Xiangrun
Molecular sieve introduction-XiangrunMolecular sieve introduction-Xiangrun
Molecular sieve introduction-Xiangrun
 
Depth Filter flyer - final
Depth Filter flyer - finalDepth Filter flyer - final
Depth Filter flyer - final
 
Oil Technics Ltd: AFFF-LF Fire Fighting Foam
Oil Technics Ltd: AFFF-LF Fire Fighting FoamOil Technics Ltd: AFFF-LF Fire Fighting Foam
Oil Technics Ltd: AFFF-LF Fire Fighting Foam
 
Texaco Rando HD ISO 32, 48, 68 - Olio idraulico Fornid
Texaco Rando HD ISO 32, 48, 68 - Olio idraulico FornidTexaco Rando HD ISO 32, 48, 68 - Olio idraulico Fornid
Texaco Rando HD ISO 32, 48, 68 - Olio idraulico Fornid
 
Epa 7.1
Epa 7.1Epa 7.1
Epa 7.1
 
2014 CIP Summit - Lonza - Buffer Rings
2014 CIP Summit - Lonza - Buffer Rings2014 CIP Summit - Lonza - Buffer Rings
2014 CIP Summit - Lonza - Buffer Rings
 
Abdos Cataloge International
Abdos Cataloge InternationalAbdos Cataloge International
Abdos Cataloge International
 
Article Contamination Of Insufflators August 2009
Article   Contamination Of Insufflators August 2009Article   Contamination Of Insufflators August 2009
Article Contamination Of Insufflators August 2009
 
Rubber rotary drilling hose
Rubber rotary drilling hoseRubber rotary drilling hose
Rubber rotary drilling hose
 
Genie supreme 120 membrane seperator datasheet
Genie supreme 120 membrane seperator datasheetGenie supreme 120 membrane seperator datasheet
Genie supreme 120 membrane seperator datasheet
 
Greyhound Chromatography HPLC Pumps
Greyhound Chromatography HPLC Pumps Greyhound Chromatography HPLC Pumps
Greyhound Chromatography HPLC Pumps
 

Similar to 13/10/2017 Sinergroup - Membranes

Ultrafiltration membranes
Ultrafiltration membranesUltrafiltration membranes
Ultrafiltration membranesArash Abed
 
Tds barrier 80 - english (uk) - issued.05.10.2011
Tds   barrier 80 - english (uk) - issued.05.10.2011Tds   barrier 80 - english (uk) - issued.05.10.2011
Tds barrier 80 - english (uk) - issued.05.10.2011Dhananjay Tekawade
 
Elastaseal data sheet
Elastaseal data sheetElastaseal data sheet
Elastaseal data sheetDale Stauffer
 
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENTCERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENTiQHub
 
Operation Experience ARWADEX 2009
Operation Experience ARWADEX 2009Operation Experience ARWADEX 2009
Operation Experience ARWADEX 2009Sami Ahmed Syed
 

Similar to 13/10/2017 Sinergroup - Membranes (20)

Membranes Catalog
Membranes CatalogMembranes Catalog
Membranes Catalog
 
In line filters catalog
In line filters catalogIn line filters catalog
In line filters catalog
 
Ultrafiltration membranes
Ultrafiltration membranesUltrafiltration membranes
Ultrafiltration membranes
 
In line filters catalogue
In line filters catalogueIn line filters catalogue
In line filters catalogue
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
In line filters catalogue
In line filters catalogueIn line filters catalogue
In line filters catalogue
 
EQUIPMENT
EQUIPMENTEQUIPMENT
EQUIPMENT
 
Residential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalogResidential Microfiltration Ultrafiltration Water catalog
Residential Microfiltration Ultrafiltration Water catalog
 
Tds barrier 80 - english (uk) - issued.05.10.2011
Tds   barrier 80 - english (uk) - issued.05.10.2011Tds   barrier 80 - english (uk) - issued.05.10.2011
Tds barrier 80 - english (uk) - issued.05.10.2011
 
Filtri in linea catalogo
Filtri in linea catalogoFiltri in linea catalogo
Filtri in linea catalogo
 
In line filters catalog
In line filters catalogIn line filters catalog
In line filters catalog
 
Residential microfiltration catalogue
Residential microfiltration catalogueResidential microfiltration catalogue
Residential microfiltration catalogue
 
Elastaseal data sheet
Elastaseal data sheetElastaseal data sheet
Elastaseal data sheet
 
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENTCERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
CERAMIC MEMBRANE TECHNOLOGY FOR PRODUCED WATER TREATMENT
 
Residential microfiltration catalogue
Residential microfiltration catalogueResidential microfiltration catalogue
Residential microfiltration catalogue
 
Flexeon mktf 115-res_ro_pb_hr_locked
Flexeon mktf 115-res_ro_pb_hr_lockedFlexeon mktf 115-res_ro_pb_hr_locked
Flexeon mktf 115-res_ro_pb_hr_locked
 
BenchMark Special Stains Product Guide
BenchMark Special Stains Product GuideBenchMark Special Stains Product Guide
BenchMark Special Stains Product Guide
 
Diffuser1
Diffuser1Diffuser1
Diffuser1
 
Operation Experience ARWADEX 2009
Operation Experience ARWADEX 2009Operation Experience ARWADEX 2009
Operation Experience ARWADEX 2009
 

More from Depuratori Acqua Osmosi Inversa Addolcitori Sinergroup

More from Depuratori Acqua Osmosi Inversa Addolcitori Sinergroup (20)

Ultrafiltration catalog
Ultrafiltration catalogUltrafiltration catalog
Ultrafiltration catalog
 
Ultrafiltrazione catalogo
Ultrafiltrazione catalogoUltrafiltrazione catalogo
Ultrafiltrazione catalogo
 
Tester and rapid kit for analysis catalog
Tester and rapid kit for analysis catalogTester and rapid kit for analysis catalog
Tester and rapid kit for analysis catalog
 
Tester e Kit rapidi per analisi catalogo
Tester e Kit rapidi per analisi catalogoTester e Kit rapidi per analisi catalogo
Tester e Kit rapidi per analisi catalogo
 
Control and dosing instruments catalog
Control and dosing instruments catalogControl and dosing instruments catalog
Control and dosing instruments catalog
 
Strumenti di controllo e dosaggio catalogo
Strumenti di controllo e dosaggio catalogoStrumenti di controllo e dosaggio catalogo
Strumenti di controllo e dosaggio catalogo
 
UV System For Air catalog
UV System For Air catalogUV System For Air catalog
UV System For Air catalog
 
Sistemi UV per aria catalogo
Sistemi UV per aria catalogoSistemi UV per aria catalogo
Sistemi UV per aria catalogo
 
UV Systems For Everpure Cartridges catalog
UV Systems For Everpure Cartridges catalogUV Systems For Everpure Cartridges catalog
UV Systems For Everpure Cartridges catalog
 
Sistemi UV per cartucce Everpure catalogo
Sistemi UV per cartucce Everpure catalogoSistemi UV per cartucce Everpure catalogo
Sistemi UV per cartucce Everpure catalogo
 
UV Systems catalog
UV Systems catalogUV Systems catalog
UV Systems catalog
 
Sistemi UV catalogo
Sistemi UV catalogoSistemi UV catalogo
Sistemi UV catalogo
 
Faucets columns fonts catalog
Faucets columns fonts catalogFaucets columns fonts catalog
Faucets columns fonts catalog
 
Rubinetteria e colonnine catalogo
Rubinetteria e colonnine catalogoRubinetteria e colonnine catalogo
Rubinetteria e colonnine catalogo
 
Water Coolers catalog
Water Coolers catalogWater Coolers catalog
Water Coolers catalog
 
Refrigeratori acqua catalogo
Refrigeratori acqua catalogoRefrigeratori acqua catalogo
Refrigeratori acqua catalogo
 
Resins and filtering medias catalog
Resins and filtering medias catalogResins and filtering medias catalog
Resins and filtering medias catalog
 
Resine e masse filtranti catalogo
Resine e masse filtranti catalogoResine e masse filtranti catalogo
Resine e masse filtranti catalogo
 
Fittings - Brass fit tubing and valves catalog
Fittings - Brass fit tubing and valves catalogFittings - Brass fit tubing and valves catalog
Fittings - Brass fit tubing and valves catalog
 
Raccordi, tubi e valvole in ottone catalogo
Raccordi, tubi e valvole in ottone catalogoRaccordi, tubi e valvole in ottone catalogo
Raccordi, tubi e valvole in ottone catalogo
 

Recently uploaded

BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessAggregage
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadAyesha Khan
 
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptxBanana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptxgeorgebrinton95
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...lizamodels9
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfmuskan1121w
 
Catalogue ONG NUOC PPR DE NHAT .pdf
Catalogue ONG NUOC PPR DE NHAT      .pdfCatalogue ONG NUOC PPR DE NHAT      .pdf
Catalogue ONG NUOC PPR DE NHAT .pdfOrient Homes
 
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdfCatalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdfOrient Homes
 
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts ServiceVip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Serviceankitnayak356677
 
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncrdollysharma2066
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewasmakika9823
 
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCRsoniya singh
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis UsageNeil Kimberley
 
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...lizamodels9
 
M.C Lodges -- Guest House in Jhang.
M.C Lodges --  Guest House in Jhang.M.C Lodges --  Guest House in Jhang.
M.C Lodges -- Guest House in Jhang.Aaiza Hassan
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckHajeJanKamps
 

Recently uploaded (20)

BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for Success
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
 
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptxBanana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptx
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdf
 
Catalogue ONG NUOC PPR DE NHAT .pdf
Catalogue ONG NUOC PPR DE NHAT      .pdfCatalogue ONG NUOC PPR DE NHAT      .pdf
Catalogue ONG NUOC PPR DE NHAT .pdf
 
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdfCatalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
 
Best Practices for Implementing an External Recruiting Partnership
Best Practices for Implementing an External Recruiting PartnershipBest Practices for Implementing an External Recruiting Partnership
Best Practices for Implementing an External Recruiting Partnership
 
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts ServiceVip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Service
 
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
 
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage
 
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
 
M.C Lodges -- Guest House in Jhang.
M.C Lodges --  Guest House in Jhang.M.C Lodges --  Guest House in Jhang.
M.C Lodges -- Guest House in Jhang.
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
 

13/10/2017 Sinergroup - Membranes

  • 1.
  • 3. Membranes Code: 090001 Filmtec membrane TFC TW30 1812 - 50, 75, 100 GPD (25) Variants Code Description 090001-01 Filmtec membrane TFC TW30 1812 - 50 GPD (25) 090001-02 Filmtec membrane TFC TW30 1812 - 75 GPD (25) 090001-03 Filmtec membrane TFC TW30 1812 - 100 GPD (25) Code: 090005 Greenfilter membrane TFC 1812/2012/3012/3013 - 50, 75, 100, 150, 180, 300, 400 GPD Variants Code Description 090005-50 Greenfilter membrane TFC 1812 - 50 GPD (25) 090005-75 Greenfilter membrane TFC 1812 - 75 GPD (25) 090005-100 Greenfilter membrane TFC 1812 - 100 GPD (25) 090005-150 Greenfilter membrane TFC 1812 - 150 GPD (25) 090005-180 Greenfilter membrane TFC 2012 - 180 GPD (25) 090005-300 Greenfilter membrane TFC 3012 - 300 GPD (1) 090005-400 Greenfilter membrane TFC 3013 - 400 GPD (1) Definition Reverse osmosis process is based on nature and has been used for more than 30 years. These semi- permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. 13 October 2017 3/18
  • 4. Spacer: EPDM SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090005-50 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090005-75 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 100 GPD Cod. 090005-100 Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 150 GPD Cod. 090005-150 Active surface: x,xxm²(xft²) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts rejection(N2) 97,5% * Recovery del 15% Membrane 180 GPD Cod. 090005-180 Active surface: x,xxm²(xft²) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts rejection(N2) 93% * Recovery del 15% Membrane 300 GPD Cod. 090005-300 Active surface: x,xxm²(xft²) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts rejection(N2) 95% * Recovery del 15% Membrane 400 GPD Cod. 090005-400 Active surface: x,xxm²(xft²) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts rejection(N2) 95% * Recovery del 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm OPERATING LIMITS OF 150, 180, 300,400 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 8,6 bar (125 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * Free Chlorine tolerance¹ <0,1 ppm ¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION 13 October 2017 4/18
  • 5. • All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite and propylene glycol to prevent biological growth in short-term storage and transport. • It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • To prevent biological growth during prolonged system shutdown, it is recommended that membrane elements be immersed in a preservative solution. • The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Code: 090018 Greenfilter encapsulated membranes TFC 50, 75, 100 GPD Variants Code Description 090018-01 Greenfilter encapsulated membrane TFC 50 GPD 090018-02 Greenfilter encapsulated membrane TFC 75 GPD 090018-03 Greenfilter encapsulated membrane TFC 75 GPD Filmtec 090018-04 Greenfilter encapsulated membrane TFC 100 GPD High efficiency, disposable encapsulate membranes. Change complete of vessel + membrane for maximum hygiene! These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. Spacer: EPDM SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090018-01 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090018-02 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090018-03 Filmtec® 13 October 2017 5/18
  • 6. Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 100 GPD Cod. 090018-04 Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% Connections: * Inlet water: O.D. stem Ø 3/8" * Outlet permeate: O.D. stem Ø 1/4" * Drain: O.D. stem Ø 1/4" OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm ¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION • It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • The membrane has a certain short-term resistance against chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Note: The polluting agents removed or reduced by this system are not necessarily in your water. Code: 090017 Ionicore USmotic membrane TFC 2012 - 50, 75, 100, 150, 180 GPD (25) Features 13 October 2017 6/18
  • 7. Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day) Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day) Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day) Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day) Permeate flow rate (+/-20%) 180: 180 Gpd (681 lt./day) Minimum salt rejection: 96% Stabilized salt rejection: 98% Operating pressure test: 65 PSI TDS feed test: Tap Water (from 450 to 700 ppm) Water temperature test: 77°F. (25°C.) Recovery test: 15% Max. operating pressure: 125 PSIG / 0.86 MPa (8,6 Bar) Max. feed SDI: 5 (15 min) Max. feed flow rate: 2 gal./min. (7,57 lt./min.) Chlorine tolerance: <0.1 ppm Max. operating temperature: 113°F. (45°C.) Ph range: 2-11 Max. feed water turbidity: 1 NTU Membrane style: Dry Variants Code Description 090017-050 Ionicore USmotic membrane TFC 2012 - 50 GPD (25) 090017-075 Ionicore USmotic membrane TFC 2012 - 75GPD (25) 090017-100 Ionicore USmotic membrane TFC 2012 - 100GPD (25) 090017-150 Ionicore USmotic membrane TFC 2012 - 150GPD (25) 090017-180 Ionicore USmotic membrane TFC 2012 - 180GPD (25) The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * High Rejection & Flow Rate * Made in the USA * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 µm. 2. Polysulfone 40 µm. 3. Non woven fabric polyester 120 µm. Spacer: EPDM Active surface: 50 GPD 0.35 m2 (3.8 sq. ft) 75 GPD 0.35 m2 (3.8 sq. ft) 100 GPD 0.52 m2 (5.6 sq. ft) 150 GPD 0.58 m2 (6.2 sq. ft) 13 October 2017 7/18
  • 8. 180 GPD 0.64 m2 (6.9 sq. ft) TFC Nominal Rejection Characteristics: Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months. 13 October 2017 8/18
  • 9. Code: 090019 Pentair GRO encapsulated membranes TLC 36, 50, 75 GPD (16) Variants Code Description 090019-01 Pentair GRO-36EN GPD encapsulated membranes 090019-02 Pentair GRO-50EN GPD encapsulated membranes 090019-03 Pentair GRO-75EN GPD encapsulated membranes GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high quality reverse osmosis water while wasting 3 times less water to the drain. Features * TLC Thin Layer Composite membrane * 100% dry membrane maximizing shelf life * Double the recovery over standard RO elements * High rejection stability at high input TDS * Maximal Pressure: 6.90 bar * Maximal Temperature: 49°C * pH: 4-11 * Free Chlorine: 0.1 ppm Connections: * Inlet water: 1/4" Quick Fit * Outlet permeate: 1/4" Quick Fit * Drain: 1/4" Quick Fit Benefits * 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO ) * High performances even under extreme conditions * Membrane can be stored for a longer period of time Nominal performance GRO-36EN * Flow* Gpd (Lpd): 36 (136.3) * Rejection: 96% * Drain flow control (ml./min.): 100 Nominal performance GRO-50EN * Flow* Gpd (Lpd): 50 (189.3) * Rejection: 96% * Drain flow control (ml./min.): 150 Nominal performance GRO-75EN * Flow* Gpd (Lpd): 75 (283.9) * Rejection:96% * Drain flow control (ml./min.): 200 13 October 2017 9/18
  • 10. Note: The data above is based on internal laboratory testing. * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 50% recovery after 24 hours. Individual element flux may vary ± 15%. The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against NSF/ANSI Standard 58 for materials and structural integrity requirements. Here is the expected amount of water saved each year, for a family of 4 people: Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt. Standard RO membrane: 17’520 lt. of rejected water GRO membrane: 4’380 lt. of rejected water The use of GRO membranes allows a saving of about 13’000 lt. of water per year. Code: 090012 Pentair membrane TLC 50, 75, 100 GPD (25) Variants Code Description 090012-050 Pentair membrane TLC - 50GPD (25) 090012-075 Pentair membrane TLC - 75GPD (25) 090012-100 Pentair membrane TLC - 100GPD (25) TLC™ RESIDENTIAL RO MEMBRANES The best way to assess the overall filtration quality of a RO system is made by measuring the rejection, which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the rejection, the better the membrane performs. The recovery of a RO system represents the quantity of permeate produced compared with the quantity of concentrate rejected to the drain. The higher the recovery, the lower the rejection is. RO MEMBRANE’S CONSTRUCTION The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around a perforated central tube. Purified water passes through the membrane and is collected in the permeate collection material while rejected impurities stay in the feed channel spacer. TLC™ RANGE TLC™ (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any types of needs from the customer. Dimensions of these membranes are standard; they will fit into any reverse osmosis systems from the market. FEATURES • TLC Thin Layer Composite membrane • 100% dry membrane maximizing shelf life • High rejection stability at high input TDS • Standard dimensions: can be fitted in any RO systems • Maximal Pressure: 6.90 bar • Maximal Temperature: 49°C • pH: 4-11 • Hardness: 17°F • Free Chlorine: 0.1 ppm 13 October 2017 10/18
  • 11. • Rejection*: 98% NOMINAL PERFORMANCE TLC-50 • Flow* Gpd (Lpd): 50 (189.3) NOMINAL PERFORMANCE TLC-75 • Flow* Gpd (Lpd): 75 (283.9) NOMINAL PERFORMANCE TLC-100 • Flow* Gpd (Lpd): 100 (378.5) * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 15% recovery after 24 hours. Individual element flux may vary ± 15%. BENEFITS OF TLC™ MEMBRANES 100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag. We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost endless! HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS Whatever the amount of total dissolved solids from the inlet water, TLC™ membranes will always give optimal performances. When compared with a membrane from competition, we can clearly see that Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at 1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**. **Results obtained from internal testing (more testing results are available upon request) NSF CERTIFIED Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will save time and money during the NSF certification process of the complete RO system by the OEM. NSF COMPONENT The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS IMPORTANT INFORMATION Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC Membranes are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane element performance can be affected by fluctuations in water quality. Code: 090007 AMI membrane TFC 1812/3012 100, 150, 300 GPD (25) 13 October 2017 11/18
  • 12. Variants Code Description 090007-100 AMI membrane TFC 1812 - 100GPD (25) 090007-150 AMI membrane TFC 1812 - 150GPD (25) 090007-300 AMI membrane TFC 3012 - 300GPD (25) AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality. Recommended Operating Conditions (50, 75, 100, 150gpd) * Maximum operating pressure: 125 psi (8,61bar) * Maximum feed flow rate: 2 gpm (7,57lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 5 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Minimum brine flow to permeate flow ratio: 4:1 * Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm) * Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm) Note: Salt rejection and performance specifications shown are from internal test data. Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C) feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%. The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits loosely, you may need to wrap a few layers of tape near one end to make a tight fit. Recommended Operating Conditions (300gpd) * Maximum operating pressure: 300 psi (20,68bar) * Maximum feed flow rate: 6 gpm (22,71lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Single Element recovery: 15% * Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm) Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8 and 10% recovery. Element permeate flow may vary ± 15%. Code: 090008 AMI nanofiltration membrane NF 1812 - 150, 200 GPD (25) 13 October 2017 12/18
  • 13. Variants Code Description 090008-150 AMI nanofiltration membrane NF 1812 - 150GPD (25) 090008-200 AMI nanofiltration membrane NF 1812 - 200GPD (25) Nanofiltration Membrane Elements: NF5 What is Nanofiltration? Nanofiltration (NF), in concept and operation, is much the same as reverse osmosis. The key difference is the degree of removal of monovalent ions such as chlorides. Reverse osmosis removes the monovalent ions at 98-99% level at 200psi (13,78bar). Nanofiltration membranes’ removal of monovalent ions varies between 50% to 90% depending on the material and manufacture of the membrane. For this reason, there is a variety of Nanofiltration membranes available. Each type is particularly suited to a certain application and may not be acceptable to a different application. Nanofiltration membranes (NF membranes) and systems are used for water softening, food and pharmaceutical applications. Recommended Operating Conditions * Maximum operating pressure: 300psi (20,68bar) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <1 ppm * Maximum Pressure Drop: 13psi (0,89bar) * Feed water pH range, Continuous Operation: 4-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Average Salt Rejection: 50% * Average Hardness Rejection: +97% * Dimensions: L-11,75"(29,85cm) I-10,25"(26,03cm) D-3"(7,61cm) Note: Performance specifications based on 2000 mg/l magnesium sulfate, 70 psi (4.8 bar) applied pressure, 77ºF (25ºC) feed water temperature and 15% recovery. Element permeate flow may vary -20%/+30%. Code: 090006 NF90-2012 nanofiltration membrane - 180 GPD (25) Variants Code Description 090006-01 NF90-2012 nanofiltration membrane - 180 GPD (25) ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide composite membrane elements display an outsdanding salt rejection of more than 97% , superior product water flow , high thermal and pressure durability , wide tolerance of chlorine and PH. SPECIFICATIONS OF PRODUCT Membrane 180GPD Cod. 090006-01 NF90-2012 NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD 13 October 2017 13/18
  • 14. Test condition Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm * Recovery: 15% Operating limits Max. temperature 40ºC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) * Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm Caution Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to stabilized Code: 090002 Housings 2,5'' for reverse osmosis membrane 1812, 2012 - 50, 75, 100, 150, 180GPD (25) Variants Code Description 090002-02 Housings 2,5'' for reverse osmosis membrane 1812, 2012 low pressure 1/8" (25) - LAST PIECES 090002-05 1812, 2012 Housing Wrench for cod. 090002-02 090002-04 Housings 2,5'' for reverse osmosis membrane 1812, 2012 high pressure doppio o-ring 1/8" (40) 090002-06 Housings 2,5'' for reverse osmosis membrane 1812, 2012 high pressure 1/8" (25) 090002-03 1812, 2012 Housing Wrench for cod. 090002-06 With double o-ring. Code: 090009 Housings for reverse osmosis membrane 3012 - 300GPD (12) Connections * Inlet/Outlet: 1/4"-3/8" * Drain: 1/4 " 13 October 2017 14/18
  • 15. Code: 090011 Housings for reverse osmosis membrane 3012 - 300GPD Greenfilter (1) Connections * Inlet: 1/8" * Outlet/Drain: 1/8" Code: 090014 Yarn Home membrane TFC 3013 - 400 GPD (1) Code: 090015 Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips Connections * Inlet: 3/8" * Outlet/Drain: 1/4" 13 October 2017 15/18
  • 16. Code: 090016 Vessel for reverse osmosis membrane 3013 - 400GPD Connections * Inlet: 1/4" * Outlet/Drain: 1/8" Code: 090013 Greenfilter membrane TFC LP2514, LP2521, LP2540, LP4040 Medium pressure Variants Code Description 090013-01 Greenfilter membrane TFC LP2521 Medium pressure 090013-02 Greenfilter membrane TFC LP2540 Medium pressure 090013-03 Greenfilter membrane TFC LP4040 Medium pressure 090013-04 Greenfilter membrane TFC LP2514 Medium pressure Code: 090020 Housings 4" for reverse osmosis membrane 4040x1 - 300psi- EP Greenfilter Variants Code Description 090020-02 Housings 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter 13 October 2017 16/18
  • 17. Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02 Features: * Made of fiber reinforced polyester. * Front connection, permeate the collection at both ends. * Close by blocking half-length AISI-304 easy membrane replacement. * EPDM seals. ABS collector plugs. * Compatible with standard 4 "membranes. * Support brackets included. Connections: * Inlet: 1/2" BSP F. * Outlet/Drain: 3/4" BSP F Technical features: * Pressure: 21 kg/cm2, 21 bar (300 psi) * Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi) * Max. temperature: 49°C (120.2°F) * Min. temperature: -10°C (14°F) * pH range, continuous operation: 3-11 * pH range, short-term cleaning: 2-12 (max 30 min.) * Weight: 6 kg 13 October 2017 17/18