3. Optical instruments:
Integrating Sphere – Lumen measurement of
luminaire, Chromaticity, Color Rendering Index,
Dominant Wavelength, FWHM,
Lux meter – Lux value measurement at specific
distance, Ft-Cd measurements.
Luminance Meter –Luminance
measurements at surface (Cd/ m2)
Spectroradiometer – Exact Color and
spectrum (W/ m2 –sr-nm)
Goniophotometer/Goniospectrometer
- Generating IES files for luminaire, polar curves,
4. Thermal Measurements:
Thermocouples, (Contact mode method) –
Temperature profile of LED module and Luminaire with
respect to room temperature, Thermocouple needs to
be <+/-1.1C or +/-0.4% accuracy for Case Temperature
during test
Infra-red pyrometers, (Non-contact mode
method)– Junction temperature measurement, heat
sink temperature.
Digital Temperature Meter - Temperature
profile of LED Luminaire
5. Electrical Measurement
Equipment:
Power Supply analyzer - Electrical
parameters such as Total power, Power Factor, Total
Harmonic Distortion,
AC regulated power supply
DC regulated power supply (Constant
Current)
Megger – insulation testing,
Leakage current meter –
Earth Resistant Test (ECR)-
V,A,W Test Meter -
7. For indoor – min 15’x10’ room with height
of12’ and arrangement for mounting luminaire
horizontally and vertically at various heights,
This room will have all dark walls with reflection
les than 10%.
This placed will be used to check lux values of
luminaire/lamp,
8. ANSI/NEMA Standards to SSL products -
•C78.377-2008 - Specifications for the Chromaticity of Solid State Lighting
Products
•NEMA SSL-1 † Power Supply - Will specify operational characteristics and
electrical safety of SSL power supplies and drivers.
•C82.77-2002 - Harmonic Emission Limits – Related Power Quality
Requirements for Lighting
IESNA Documents –
•TM-16-05 - IESNA Technical Memorandum on Light Emitting Diode (LED)
Sources and Systems.
•RP-16-05 - Addendum a Nomenclature and Definitions for Illuminating
Engineering.
•LM-79-08 - IESNA Approved Method for the Electrical and Photometric
Measurements of Solid-State Lighting Products,
•LM-80-08 - IESNA Approved Method for Measuring Lumen Maintenance of LED
Light Sources.
•TM-21† - Lumen Depreciation Lifetime Estimation Method for LED Light.
•LM-80. LM-XX† Method for the Measurements of High-Power LEDs.