The document provides information about an AHU Communication Kit that allows control of air handling unit functions using LG outdoor units. It includes:
1) Details on return air and discharge air temperature control communication kits, which measure air temperatures and control expansion valves and outdoor units to maintain set temperatures.
2) Specifications and dimensions for the communication kits and their components.
3) Explanations of different control solutions for integrating the kits with LG controllers, third party DDC systems, or a combination using contact signals, Modbus, or central controllers.
4) Diagrams illustrating how the kits can be installed in air handling unit applications to control temperature based on return, discharge or room air levels.
This document discusses free floating logic in KNX home automation systems. Free floating logic allows logic operations to occur between any KNX devices independently, without being tied to a specific device. The document outlines the components of free floating logic, including triggers that initiate the logic, execution conditions that filter the state, logic operations like AND and OR, and result operations that determine what is sent after calculations. An example is provided of using free floating logic for HVAC zone control with 4 zones tied to 4 data entry points, with the final result linking to the main unit or boiler.
The document provides information on the Siemens PXC Controller Series. It discusses the PXC Compact series controllers and their flexibility to customize control programs for applications. It also describes the controllers' direct digital control routines, energy management applications, operator interface, PPCL programming language, and more. Troubleshooting tips are also included.
Marco Fusca, Sales & Marketing Refrigeration Application Specialist at ATMO Virtual Trade Show 2021. CAREL has a complete range of high efficiency solutions for propane retail applications. CAREL is ready for 500 g with an extended range of PED cat 1 BLDC compressors. A special package has been specifically developed for 150 g air-cooled applications. The common technology is Heos: continuous modulation delivered to water-cooled or plug-in air-cooled applications, with the goal to maximise system efficiency and reliability.
Know more: natref.carel.com
The ThermalAir TA-5000 is a temperature testing system that provides precise temperature control from -80°C to +225°C. It uses DC temperature control and a smart energy efficient chiller to adjust temperatures instantly and save energy. The system features include built-in touch screens, quiet operation, and no need for liquid nitrogen or dry ice. It allows remote control via smart phones or tablets and provides versatile testing of electronic components.
This document provides an overview and instructions for using the SNET Pro 2 service software to monitor and program Samsung DVM S HVAC systems. It describes the software's main functions and screens, how to connect the USB-RS485 converter, navigate the user interface, view system and unit data, generate trend graphs, and replay recorded data files. Instructions are included for changing unit names, monitoring operation in real-time, and retrieving backup data after a system error occurs.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://www.instagram.com/controlsandsystems.offical
https://twitter.com/ControlsSystems
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
www.controls.systemsdm@gmail.com
If you enjoyed this article, share it with your friends and colleagues
The document provides information about an AHU Communication Kit that allows control of air handling unit functions using LG outdoor units. It includes:
1) Details on return air and discharge air temperature control communication kits, which measure air temperatures and control expansion valves and outdoor units to maintain set temperatures.
2) Specifications and dimensions for the communication kits and their components.
3) Explanations of different control solutions for integrating the kits with LG controllers, third party DDC systems, or a combination using contact signals, Modbus, or central controllers.
4) Diagrams illustrating how the kits can be installed in air handling unit applications to control temperature based on return, discharge or room air levels.
This document discusses free floating logic in KNX home automation systems. Free floating logic allows logic operations to occur between any KNX devices independently, without being tied to a specific device. The document outlines the components of free floating logic, including triggers that initiate the logic, execution conditions that filter the state, logic operations like AND and OR, and result operations that determine what is sent after calculations. An example is provided of using free floating logic for HVAC zone control with 4 zones tied to 4 data entry points, with the final result linking to the main unit or boiler.
The document provides information on the Siemens PXC Controller Series. It discusses the PXC Compact series controllers and their flexibility to customize control programs for applications. It also describes the controllers' direct digital control routines, energy management applications, operator interface, PPCL programming language, and more. Troubleshooting tips are also included.
Marco Fusca, Sales & Marketing Refrigeration Application Specialist at ATMO Virtual Trade Show 2021. CAREL has a complete range of high efficiency solutions for propane retail applications. CAREL is ready for 500 g with an extended range of PED cat 1 BLDC compressors. A special package has been specifically developed for 150 g air-cooled applications. The common technology is Heos: continuous modulation delivered to water-cooled or plug-in air-cooled applications, with the goal to maximise system efficiency and reliability.
Know more: natref.carel.com
The ThermalAir TA-5000 is a temperature testing system that provides precise temperature control from -80°C to +225°C. It uses DC temperature control and a smart energy efficient chiller to adjust temperatures instantly and save energy. The system features include built-in touch screens, quiet operation, and no need for liquid nitrogen or dry ice. It allows remote control via smart phones or tablets and provides versatile testing of electronic components.
This document provides an overview and instructions for using the SNET Pro 2 service software to monitor and program Samsung DVM S HVAC systems. It describes the software's main functions and screens, how to connect the USB-RS485 converter, navigate the user interface, view system and unit data, generate trend graphs, and replay recorded data files. Instructions are included for changing unit names, monitoring operation in real-time, and retrieving backup data after a system error occurs.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://www.instagram.com/controlsandsystems.offical
https://twitter.com/ControlsSystems
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
www.controls.systemsdm@gmail.com
If you enjoyed this article, share it with your friends and colleagues
The Sunny Tripower 15000TL three-phase inverter has maximum efficiency of 98.2% and innovative grid management functions like integrated plant control and reactive power available 24/7. It has a flexible design with input voltage up to 1000V and two MPP trackers. Reliability is ensured through triple protection of electronic string fuse, string failure detection, and surge arrester.
HDD Test area aircon system improvement designJedh Quenano
HDD Test Area Air-Conditioning System Improvement (President's Award)
Honor date: December 2005
Honor issuer: Kazuya Takeda, HICAP President
Honor description: President's Award
Attained 24-26 deg C temperature improvement inside Microdrive Test resulting to 93-94% yield result for HICAP operations beside worker's improved working environment condition.
This document provides information on the features, functions, specifications, and operation of an M1M 12 multi-function meter. Some key points include:
1. It has inputs for 3-phase 4-wire or 3-phase 3-wire systems and can measure voltages, currents, power parameters, and energy.
2. Wiring should follow electrical codes and grounding is required. The meter has LED displays, buttons for navigation, and communication via RS485 MODBUS.
3. Technical specifications include measurement categories of CAT III, voltage and current ranges and accuracies of 1%, operating temperature range of -10°C to 60°C, and IP51 protection.
World's ultimate Outdoor LCD Screens designed for adverse weatherKevin Andreassend
ICE AV once more delivers leading edge display technology. The outdoor LCD screens are designed for use in full brilliant killer hot daylight or freezing temperatures. No other product can match the performance to prevent screen burn out, glass shatter and delivers brilliant bright images. Available as a full enclose system in up to 70" dia screen. Whether it is a ski field in Queenstown, raining environment of Cairns, in the outdoor environment of Dubai and as Samsung discovered - it is the preferred outdoor display solution in the Samsung Everland Entertainment Park in Korea. Contact sales at iceav co nz for further details
The FlexStat is a controller and sensor that provides flexible HVAC control solutions. It has temperature sensing as well as optional humidity, motion, and CO2 sensing. It can be configured for applications such as air handling units, fan coil units, heat pumps, and more. It has inputs and outputs that are configurable, as well as on-board programming. Models vary in their number of relays and analog outputs as well as optional integrated sensors. It communicates using BACnet and models are available with Ethernet connectivity. It provides flexible control capabilities in a compact and cost-effective package.
The Meitav-tec FCC_01 Free Cooling Controller is a wall mount thermostat that saves energy by taking advantage of cooler outdoor air temperatures. It has an open/auto/close switch to control a damper, fan, or window. Sensors monitor indoor and outdoor temperatures, and it will open the damper or window when outside air is cooler than inside by the default 1°C difference. Accessories include indoor and outdoor temperature sensors and a decorative back plate.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
If you enjoyed this article, share it with your friends and colleagues
The document provides information on Eaton's H-Max drive update and Intellipass solution. Some key highlights include:
- The H-Max drive offers sizes from 1-250HP and improvements over previous models like active energy control, a real-time clock, enhanced communications options, and EN 61800-3 C2 EMI/RFI filtering.
- The Intellipass solution combines the H-Max drive with additional components like contactors and a power supply in a NEMA 1 enclosure for simplified installation and energy savings.
- Transition plans and competitive advantages over other manufacturers' solutions are discussed.
The document describes a hands-on lab using a PowerFlex drive to control fan speed using a PI regulator to maintain constant air pressure. The drive is configured to use a constant setpoint as the reference and an analog input for feedback from a pressure transducer. Digital and analog I/O are configured and the PI regulator is tuned by adjusting proportional gain and integral time parameters to control fan speed in response to a simulated pressure demand change using a damper.
The document describes the Carrier Aspire range of inverter hi-wall air conditioners. It provides specifications for 6 indoor unit models and their corresponding outdoor units, including cooling and heating capacities, power consumption, dimensions, noise levels, and other technical details. It highlights that the units use DC inverter technology for better comfort and power saving, and touts features like automatic error diagnosis, louver position memory, silent mode, and a 5-year warranty.
This document provides product documentation for the Liebert HPS high performance split air conditioner. The Liebert HPS family includes ceiling mounted and wall mounted indoor units that can be coupled with outdoor units. It offers benefits such as optimal air distribution in the cooled space, high cooling efficiency, energy savings through free cooling options, reliability, flexibility in configurations, and respect for the environment through use of green refrigerants and a high efficiency refrigeration cycle. The document describes the product features, model selection details, mechanical specifications, control options, and other technical information.
This document provides an overview of building energy simulation using EnergyPlus. It defines simulation, discusses the goals and importance of building thermal simulation, and reviews key concepts in EnergyPlus. EnergyPlus is an integrated building energy simulation program that can model time-dependent heat transfer, HVAC systems, and plant systems. The document outlines EnergyPlus' input/output file structure and integrated simulation manager. It also addresses common questions about running simulations and validating results.
The document provides specifications for a 42.1-inch LED-backlit LCD display. It includes:
1) Descriptions of the display's features such as its size, resolution, brightness, and inputs/outputs.
2) Electrical, timing, power, and mechanical specifications for the LCD panel and driving board.
3) Optical specifications covering the display's color performance, viewing angles, and brightness.
4) Details on the LED driving board including its electrical characteristics, connectors, and dimensions.
5) Information on the AD control board and its video input/output capabilities and control functions.
This document provides information on LG's commercial air conditioner solutions, focusing on their smart inverter single central air conditioning (CAC) units. It highlights key benefits including energy savings of up to 22% compared to constant speed models, intelligent features like human detection and wireless control via LG ThinQ, and reliability elements such as corrosion resistance. A variety of indoor unit types are also presented, including 1 way and 4 way ceiling cassette units, ceiling concealed duct units, and floor standing units. Product lineups by capacity are shown, ranging from 9,000 to 60,000 BTU for single phase units and 30,000 to 100,000 BTU for 3 phase units.
PID is short for "proportional plus integral and derivative", three algorithm components used by this type of controller in managing a control loop. Process loop controllers use one, two or all three of these to optimally control the process system. PID control is used in a wide variety of applications in industrial control and process system management.
Heatmiser heating controls catalogue 2016. All you need for controlling your boiler system. Full range at Plumb4Less http://plumb4less.co.uk/index.php?cPath=27_27&osCsid=ojo58a02a022ji274t3n0pu462
The PLIO03 is a compact, programmable I/O module designed as an optional plug-in for eTOP Series 500 HMI products. It offers 20 digital inputs, 12 digital outputs, 4 analog inputs, and 4 analog outputs. The module has been designed for flexibility with configurable channels and easy wiring.
Smart din rail module product sheet 1.3 websitefifthplay
The smart DIN rail module provides a way to remotely measure and control the energy consumption of individual circuits. It can measure electricity usage in 15-minute intervals and power usage in real-time, and circuits can be controlled on or off remotely via the internet. The module installs easily on a DIN rail and communicates wirelessly via RF to a gateway. It has features like power and usage measurements, remote on/off control, local on/off button, and LED indicators.
Learn the basics of DALI network (Digital Addressable Lighting Interface).
The session will cover:
-Topology: Rules for wiring and power supply
-Network design
-Commissioning
-Integration with other systems
-DALI device types
-The DALI standard
Everything you need to know to get started working on DALI.
More Related Content
Similar to Ivory Egg Zennio Training KLIC HVAC Webinar
The Sunny Tripower 15000TL three-phase inverter has maximum efficiency of 98.2% and innovative grid management functions like integrated plant control and reactive power available 24/7. It has a flexible design with input voltage up to 1000V and two MPP trackers. Reliability is ensured through triple protection of electronic string fuse, string failure detection, and surge arrester.
HDD Test area aircon system improvement designJedh Quenano
HDD Test Area Air-Conditioning System Improvement (President's Award)
Honor date: December 2005
Honor issuer: Kazuya Takeda, HICAP President
Honor description: President's Award
Attained 24-26 deg C temperature improvement inside Microdrive Test resulting to 93-94% yield result for HICAP operations beside worker's improved working environment condition.
This document provides information on the features, functions, specifications, and operation of an M1M 12 multi-function meter. Some key points include:
1. It has inputs for 3-phase 4-wire or 3-phase 3-wire systems and can measure voltages, currents, power parameters, and energy.
2. Wiring should follow electrical codes and grounding is required. The meter has LED displays, buttons for navigation, and communication via RS485 MODBUS.
3. Technical specifications include measurement categories of CAT III, voltage and current ranges and accuracies of 1%, operating temperature range of -10°C to 60°C, and IP51 protection.
World's ultimate Outdoor LCD Screens designed for adverse weatherKevin Andreassend
ICE AV once more delivers leading edge display technology. The outdoor LCD screens are designed for use in full brilliant killer hot daylight or freezing temperatures. No other product can match the performance to prevent screen burn out, glass shatter and delivers brilliant bright images. Available as a full enclose system in up to 70" dia screen. Whether it is a ski field in Queenstown, raining environment of Cairns, in the outdoor environment of Dubai and as Samsung discovered - it is the preferred outdoor display solution in the Samsung Everland Entertainment Park in Korea. Contact sales at iceav co nz for further details
The FlexStat is a controller and sensor that provides flexible HVAC control solutions. It has temperature sensing as well as optional humidity, motion, and CO2 sensing. It can be configured for applications such as air handling units, fan coil units, heat pumps, and more. It has inputs and outputs that are configurable, as well as on-board programming. Models vary in their number of relays and analog outputs as well as optional integrated sensors. It communicates using BACnet and models are available with Ethernet connectivity. It provides flexible control capabilities in a compact and cost-effective package.
The Meitav-tec FCC_01 Free Cooling Controller is a wall mount thermostat that saves energy by taking advantage of cooler outdoor air temperatures. It has an open/auto/close switch to control a damper, fan, or window. Sensors monitor indoor and outdoor temperatures, and it will open the damper or window when outside air is cooler than inside by the default 1°C difference. Accessories include indoor and outdoor temperature sensors and a decorative back plate.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
If you enjoyed this article, share it with your friends and colleagues
The document provides information on Eaton's H-Max drive update and Intellipass solution. Some key highlights include:
- The H-Max drive offers sizes from 1-250HP and improvements over previous models like active energy control, a real-time clock, enhanced communications options, and EN 61800-3 C2 EMI/RFI filtering.
- The Intellipass solution combines the H-Max drive with additional components like contactors and a power supply in a NEMA 1 enclosure for simplified installation and energy savings.
- Transition plans and competitive advantages over other manufacturers' solutions are discussed.
The document describes a hands-on lab using a PowerFlex drive to control fan speed using a PI regulator to maintain constant air pressure. The drive is configured to use a constant setpoint as the reference and an analog input for feedback from a pressure transducer. Digital and analog I/O are configured and the PI regulator is tuned by adjusting proportional gain and integral time parameters to control fan speed in response to a simulated pressure demand change using a damper.
The document describes the Carrier Aspire range of inverter hi-wall air conditioners. It provides specifications for 6 indoor unit models and their corresponding outdoor units, including cooling and heating capacities, power consumption, dimensions, noise levels, and other technical details. It highlights that the units use DC inverter technology for better comfort and power saving, and touts features like automatic error diagnosis, louver position memory, silent mode, and a 5-year warranty.
This document provides product documentation for the Liebert HPS high performance split air conditioner. The Liebert HPS family includes ceiling mounted and wall mounted indoor units that can be coupled with outdoor units. It offers benefits such as optimal air distribution in the cooled space, high cooling efficiency, energy savings through free cooling options, reliability, flexibility in configurations, and respect for the environment through use of green refrigerants and a high efficiency refrigeration cycle. The document describes the product features, model selection details, mechanical specifications, control options, and other technical information.
This document provides an overview of building energy simulation using EnergyPlus. It defines simulation, discusses the goals and importance of building thermal simulation, and reviews key concepts in EnergyPlus. EnergyPlus is an integrated building energy simulation program that can model time-dependent heat transfer, HVAC systems, and plant systems. The document outlines EnergyPlus' input/output file structure and integrated simulation manager. It also addresses common questions about running simulations and validating results.
The document provides specifications for a 42.1-inch LED-backlit LCD display. It includes:
1) Descriptions of the display's features such as its size, resolution, brightness, and inputs/outputs.
2) Electrical, timing, power, and mechanical specifications for the LCD panel and driving board.
3) Optical specifications covering the display's color performance, viewing angles, and brightness.
4) Details on the LED driving board including its electrical characteristics, connectors, and dimensions.
5) Information on the AD control board and its video input/output capabilities and control functions.
This document provides information on LG's commercial air conditioner solutions, focusing on their smart inverter single central air conditioning (CAC) units. It highlights key benefits including energy savings of up to 22% compared to constant speed models, intelligent features like human detection and wireless control via LG ThinQ, and reliability elements such as corrosion resistance. A variety of indoor unit types are also presented, including 1 way and 4 way ceiling cassette units, ceiling concealed duct units, and floor standing units. Product lineups by capacity are shown, ranging from 9,000 to 60,000 BTU for single phase units and 30,000 to 100,000 BTU for 3 phase units.
PID is short for "proportional plus integral and derivative", three algorithm components used by this type of controller in managing a control loop. Process loop controllers use one, two or all three of these to optimally control the process system. PID control is used in a wide variety of applications in industrial control and process system management.
Heatmiser heating controls catalogue 2016. All you need for controlling your boiler system. Full range at Plumb4Less http://plumb4less.co.uk/index.php?cPath=27_27&osCsid=ojo58a02a022ji274t3n0pu462
The PLIO03 is a compact, programmable I/O module designed as an optional plug-in for eTOP Series 500 HMI products. It offers 20 digital inputs, 12 digital outputs, 4 analog inputs, and 4 analog outputs. The module has been designed for flexibility with configurable channels and easy wiring.
Smart din rail module product sheet 1.3 websitefifthplay
The smart DIN rail module provides a way to remotely measure and control the energy consumption of individual circuits. It can measure electricity usage in 15-minute intervals and power usage in real-time, and circuits can be controlled on or off remotely via the internet. The module installs easily on a DIN rail and communicates wirelessly via RF to a gateway. It has features like power and usage measurements, remote on/off control, local on/off button, and LED indicators.
Similar to Ivory Egg Zennio Training KLIC HVAC Webinar (20)
Learn the basics of DALI network (Digital Addressable Lighting Interface).
The session will cover:
-Topology: Rules for wiring and power supply
-Network design
-Commissioning
-Integration with other systems
-DALI device types
-The DALI standard
Everything you need to know to get started working on DALI.
This document provides tips and tricks for using ETS software. It discusses the importance of ETS and IoT for connecting KNX to non-KNX systems. It also provides instructions on how to securely add devices without passwords, use context help for device parameters, organize workspaces and channels, build functions and link them, copy and paste parameters between devices, import and export to Excel, and find product templates in the ETS App. The presenter provides an overview of these topics and encourages participants to refer to an online training guide for a comprehensive reference.
This document provides an overview and summary of the Thinknx TrendLine webinar that took place on October 26th, 2023. The webinar covered TrendLine product integrations including BACNET protocol integration, ViaVai access control systems, guest room management systems, and intercom systems. It also presented the TrendLine product line including controllers, features of the visualization interface, and examples of usage in KNX systems and with Thinknx servers. Energy management plugins and BACNET integration were also briefly discussed.
This document summarizes a webinar about using KNX for metering and energy functions. It discusses how KNX can be used for energy and current relays, real meters that monitor electricity usage, interfaces for solar panels and batteries, monitoring gas, water and M-bus utilities, load shedding functions, and controlling electric vehicle chargers. Products mentioned include meters and interfaces from Zennio, ABB, Sonnen, and Elausys that can monitor energy production and consumption on the KNX network.
The document discusses the benefits of exercise for mental health. Regular physical activity can help reduce anxiety and depression and improve mood and cognitive function. Exercise causes chemical changes in the brain that may help protect against mental illness and improve symptoms.
The document provides instructions for setting up and using Thinknx automation software and servers. It includes:
1. An overview of Thinknx servers, clients, and products like the Audiofy multiroom audio system.
2. Steps for initial server setup like connecting it to power and network, accessing the web interface, updating firmware, and configuring network settings.
3. Information on creating the first project using the configurator tool, including entering a project name, server details, and optional user and license data.
This document provides an overview of a DALI Basics course. It discusses what DALI is, including that it replaces 1-10V and DSI control technologies. It covers DALI topology rules for wiring and power supplies, how to design DALI networks, and how to commission, test, and troubleshoot DALI systems. It also discusses working with other systems like KNX that integrate with DALI and the various DALI device types defined in the standard. The document concludes with information on the DALI-2 standard and IEC 62386 specification.
The document provides information about the Zennio KES Plus energy monitoring system, including:
1. Details on wiring the current transformers to monitor current and energy usage on each phase.
2. Descriptions of the objects and measurements that can be monitored like voltage, current, power, and energy.
3. Explanations of parameters that can be programmed in the ETS software like alarms and switching functions.
4. A note that the ETS project file can be requested from stuart@zennio.com.au.
The document summarizes a training presentation on the Gira X1 home automation and visualization system. It provides an overview of the Gira X1's applications, features, installation, commissioning process in ETS, and programming using the Gira Project Assistant tool. It also covers creating visualizations and operating devices using the Gira Smart Home app, as well as setting up scenes, timers, logic functions, remote access, integrating IoT services, and potential extensions. Specifications of the Gira X1 are also listed.
The document discusses remote access features of the Gira S1 device, which provides secure remote access and maintenance of KNX IP interfaces, smart home systems, and other devices. Key features highlighted include integration with Gira apps, remote access without router adjustments, support for IPv6, VPN access, and remote maintenance capabilities for ETS and HomeServer systems. It also notes the Gira S1 supports message notifications, independent internet access, and complies with German data protection laws.
This document provides tips and tricks for using ETS software. It discusses how ETS uses KNX IoT to connect KNX to non-KNX systems. It provides instructions on securing devices without passwords, using context help for device parameters, customizing workspaces and channels, building functions and linking, copying and pasting parameters between devices, finding and replacing group addresses, and importing and exporting data to and from Excel. The document aims to help users better utilize features in ETS.
"Financial Odyssey: Navigating Past Performance Through Diverse Analytical Lens"sameer shah
Embark on a captivating financial journey with 'Financial Odyssey,' our hackathon project. Delve deep into the past performance of two companies as we employ an array of financial statement analysis techniques. From ratio analysis to trend analysis, uncover insights crucial for informed decision-making in the dynamic world of finance."
Predictably Improve Your B2B Tech Company's Performance by Leveraging DataKiwi Creative
Harness the power of AI-backed reports, benchmarking and data analysis to predict trends and detect anomalies in your marketing efforts.
Peter Caputa, CEO at Databox, reveals how you can discover the strategies and tools to increase your growth rate (and margins!).
From metrics to track to data habits to pick up, enhance your reporting for powerful insights to improve your B2B tech company's marketing.
- - -
This is the webinar recording from the June 2024 HubSpot User Group (HUG) for B2B Technology USA.
Watch the video recording at https://youtu.be/5vjwGfPN9lw
Sign up for future HUG events at https://events.hubspot.com/b2b-technology-usa/
4th Modern Marketing Reckoner by MMA Global India & Group M: 60+ experts on W...Social Samosa
The Modern Marketing Reckoner (MMR) is a comprehensive resource packed with POVs from 60+ industry leaders on how AI is transforming the 4 key pillars of marketing – product, place, price and promotions.
3. AVAILABLE
Zennio bene
fi
ts:
Bi-directional (All except some IR AC units)
Analogue inputs (temp probe, motion sensor, push button or window contacts)
Free Floating Logic functions included. Zoning and aggregate temperatures
Error handling
Master / Slave option
Simpli
fi
ed mode (heat / cool only)
6. DAIKIN SYSTEMS
Daikin Industrial (VRV & SKY)
VRV, SKY,
Chosen in ETS
application program
KLIC-DI v2 KLIC-DD v3
Daikin Residential (split & concealed)
May need adapter card:
(BRP067A42, OR BRP980B42)
7. DAIKIN FIELD SETTINGS
By others -YouTube video showing:
https://www.youtube.com/watch?v=aIMixgiSjkM
Field Settings
20 2-01 Sense from both wall r/c and return air
20 2-02 Use unit air sensor only/ return air
20 2-03 Sense from wall controller only
Screen share Daikin controller
8. MITSUBISHI SYSTEMS
Option: IT signal adapter available. KLIC-MITT CN100 (9900019)
Fits the Mitsubishi circuit board connector CN100
10. ZONE LOGIC EXAMPLE
HVAC Zone Control
4 Zone. 1 head unit
Trigger : 1 bit data entry 1, 2, 3, 4.
Condition : Nil
Operation 1 : 1 bit data entry 1, or 1 bit data entry 2, = b1
Operation 2 : b1 or 1 bit data entry 3, = b2
Operation 3 : B2 or 1 bit data entry 4, = b3
Result : B3 no restriction, always.
11. ZONE LOGIC PROGRAM
Con
fi
guration : 4 x 1 bit data entries
Linking : 1 bit data entry 1, 2, 3, 4 link to zone on / off
Function result : Link to on / off of main AC unit
Group address links
HVAC Zone Control
4 Zone. 1 head unit
12. DESIGN EXAMPLE
Make open area a
spill zone (always open)
Take aggregate temperature
to send to main unit.
Eg 50/50, guest bed/family