2. PERFORMING THE ONE-PERSON FOOT-
TILT METHORD
Place one foot on the hose behind the male
coupling.
push down with your foot to tilt the male
coupling upward.
place the other hand behind the female
coupling and grasp the hose.
3.
4. PERFORMING THE TWO-PERSON
METHORD
Pick up the male end of the coupling. Grasp it
directly behind the coupling and hold it tightly
against the body.
The second brigade member hold the female
coupling firmly with both hands.
The second brigade member brings the female
coupling to the male coupling.
. The second brigade member aligns the female
coupling with the male coupling
5.
6. The second brigade member turns the
female coupling counter clockwise until it
clicks.
Turn the female coupling clockwise to
couple the hoses.
7. PERFOMING THE ONE-PERSON KNEE-PRESS
METHORD
Pick up the connection by the female coupling
end.
Turn the connection upright resting the male
coupling on a film surface.
Place a knee on the female coupling and with
body weight press down. Turn the female
swivel counterclockwise and loosen the
coupling.
8. PERFORMING THE TWO-PERSON STIFF-
ARM METHORD
Two brigade member face each other and
firmly grasp their respective coupling.
With elbows locked straight, the brigade
members push toward each other.
While pushing toward each other, the brigade
members turn the coupling counter clockwise,
loosening the coupling.
13. ADAPTORS
Adaptors are used for connecting hose couplings
of the same diameter that have dissimilar threads.
DOUBLE-FEMALE ADAPTOR-To join two
male hose couplings.
DOUBLE-MALE ADAPTOR-To join two
female hose couplings.
17. HOSE ROLLER
A roller is used to protect a hose when it is hoisted
over a sharp edge of a roof or a windowsill.
18. HOSE CLAMP
A hose clamp is used to temporarily interrupt the flow of
water in a hose line.
19. HOSE RAMP
Hose ramp is used for protecting hose from traffic
during fire fighting.
20. VALVES
Valves are used to control the flow of water in a
hose line.
1. BALL VALVES- These valves are used on nozzles,
gated wyes, and engine discharge gate.
2. GATE VALVES- These valves are found on hydrants
and on sprinkler systems.
3. BUTTERFLY VALVES- These valves are often found
on the large pump intake connections where a
hard suction hose or soft suction hose is
connected.