This document provides information on Group II Cable Glands that are certified for flameproof, increased safety, and dust protection applications in hazardous locations. It lists the certifications and standards they comply with for ATEX, IECEx, and cCSAus. It also includes technical data on operating temperature range, ingress protection ratings, deluge protection, and construction materials. Finally, it contains ordering information and a cable gland selection table with entry thread sizes and cable acceptance details.
CMP E1FW Hazardous Area Flameproof ATEX Cable Glands for Armoured Cables (SWA) in Zones 1, 2, 21 and 22
CMP E1FW Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable glands for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with steel wire armoured (SWA) cable.
CMP E1FW cable glands provide a flameproof seal on the cable inner bedding and in addition the gas tight seal has been tested to prove compatibility with Restricted Breathing equipment.
CMP E1FW flameproof cable glands allow mechanical cable retention and earth continuity via the cable armour termination.
CMP E1FW cable glands are suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22.
Dual Wall Flame Retarded Heat Shrink Tubing
Military Grade Heat Shrink : MIL-DTL 23053/4
Underwriters Lab : UL 224
CSA : 600V, 125 Degrees Celsius
Heat Shrink Tubings - Insulate, Protect & Identify
SPDW heat shrink is ideal for sealing connector to cable transitions and similar moisture proofing applications with adhesive lined tubing.
SPDW is approved to MIL-DTL 23053/4 and UL 224.
Shrinktek Dual Wall Flame Retarded Heat Shrink Tubing
Thorne & Derrick are the largest UK distributor of heat shrink tubings and sleevings including 3M, Panduit, Hellermann Tyton, DSG Canusa, Shrinktek and Thomas & Betts.
Stock lines include thin, medium and thick wall adhesive lined heat shrink sleeves and moulded shapes (heat shrink cable caps, cable breakouts and cable boots) - insulate, seal, protect with heat shrinkable tubing.
Hawke Cable Glands - 501/453 Universal A M20, 12.5-20.5mm.
Hawke Cable Gland for Hazardous Area Zones 1, 2, 21, 22
ATEX, Flameproof Hawke Glands for Armoured/Braided Cable
Hawke 501/453 universal flameproof cable glands are suitable forsteel wire armoured, steel wire braided and steel tape armoured cables - Hawke 501/453 cable glands are available in brass, nickel plated brass, 316 stainless steel and aluminium and are suitable for hazardous area Zones 1, 2, 21 and 22 installation.
Hawke 501/453 universal cable glands are ATEX certified for Flameproof and Increased Safety applications.
Hawke cable glands 501/453 incorporate innovative features that along with safety, enable fast installation, facilitate inspectability of the cable gland in operable condition and prevent corrosion of the cable wire armour or braid.
CMP E1FW Hazardous Area Flameproof ATEX Cable Glands for Armoured Cables (SWA) in Zones 1, 2, 21 and 22
CMP E1FW Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable glands for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with steel wire armoured (SWA) cable.
CMP E1FW cable glands provide a flameproof seal on the cable inner bedding and in addition the gas tight seal has been tested to prove compatibility with Restricted Breathing equipment.
CMP E1FW flameproof cable glands allow mechanical cable retention and earth continuity via the cable armour termination.
CMP E1FW cable glands are suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22.
Dual Wall Flame Retarded Heat Shrink Tubing
Military Grade Heat Shrink : MIL-DTL 23053/4
Underwriters Lab : UL 224
CSA : 600V, 125 Degrees Celsius
Heat Shrink Tubings - Insulate, Protect & Identify
SPDW heat shrink is ideal for sealing connector to cable transitions and similar moisture proofing applications with adhesive lined tubing.
SPDW is approved to MIL-DTL 23053/4 and UL 224.
Shrinktek Dual Wall Flame Retarded Heat Shrink Tubing
Thorne & Derrick are the largest UK distributor of heat shrink tubings and sleevings including 3M, Panduit, Hellermann Tyton, DSG Canusa, Shrinktek and Thomas & Betts.
Stock lines include thin, medium and thick wall adhesive lined heat shrink sleeves and moulded shapes (heat shrink cable caps, cable breakouts and cable boots) - insulate, seal, protect with heat shrinkable tubing.
Hawke Cable Glands - 501/453 Universal A M20, 12.5-20.5mm.
Hawke Cable Gland for Hazardous Area Zones 1, 2, 21, 22
ATEX, Flameproof Hawke Glands for Armoured/Braided Cable
Hawke 501/453 universal flameproof cable glands are suitable forsteel wire armoured, steel wire braided and steel tape armoured cables - Hawke 501/453 cable glands are available in brass, nickel plated brass, 316 stainless steel and aluminium and are suitable for hazardous area Zones 1, 2, 21 and 22 installation.
Hawke 501/453 universal cable glands are ATEX certified for Flameproof and Increased Safety applications.
Hawke cable glands 501/453 incorporate innovative features that along with safety, enable fast installation, facilitate inspectability of the cable gland in operable condition and prevent corrosion of the cable wire armour or braid.
CMP E1FW-50
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-50 Cable Glands - Flameproof ATEX Cable Gland - 40.4-53.1mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
CMP E1FW-40
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-40 Cable Glands - Flameproof ATEX Cable Gland - 27.9-40.4mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X -
CMP E1FW-25
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-25S Cable Glands - Flameproof ATEX Cable Gland - 18.2-26.2mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66 IECEx: IECEx SIR 06.0043X
CMP E1FW-63
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-63 Cable Glands - Flameproof ATEX Cable Gland - 54.6-65mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
CMP E1FW-50S
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-50S Cable Glands - Flameproof ATEX Cable Gland - 35.2-46.7mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
CMP E1FW-63S
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-63S Cable Glands - Flameproof ATEX Cable Gland - 45.6-59.4mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21
IP66 IECEx: IECEx SIR 06.0043X
CMP E1FW-20S
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-20S Cable Glands - Flameproof ATEX Cable Gland - 9.5-15.9mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
CMP E1FW-20S/16
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-20S/16 Cable Glands - Flameproof ATEX Cable Gland - 6.1-11.5mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
CMP E1FW-90
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-90 Cable Glands - Flameproof ATEX Cable Gland - 76.2-90.4mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
CMP E1FW-32
CMP Cable Glands For Hazardous Areas
Zone 1, Zone 2, Zone 21 & Zone 22 - ATEX & IECEx
CMP E1FW-32 Cable Glands - Flameproof ATEX Cable Gland - 23.7-33.9mm
CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable.
CMP E1FW Technical Data
Temperature Rating : -60°C to +130°C
Cable Type : Single Wire Armour (SWA) & Aluminium Wire Armour (AWA)
Cable Sealing Area : Cable Inner Bedding & Outer Cable Sheath
CMP E1FW Hazardous Area Approvals
ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Ex II 2/3 GD, Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66
IECEx: IECEx SIR 06.0043X
Similar to Hawke 501/414 Hazardous Area Cable Glands (20)
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
PHP Frameworks: I want to break free (IPC Berlin 2024)Ralf Eggert
In this presentation, we examine the challenges and limitations of relying too heavily on PHP frameworks in web development. We discuss the history of PHP and its frameworks to understand how this dependence has evolved. The focus will be on providing concrete tips and strategies to reduce reliance on these frameworks, based on real-world examples and practical considerations. The goal is to equip developers with the skills and knowledge to create more flexible and future-proof web applications. We'll explore the importance of maintaining autonomy in a rapidly changing tech landscape and how to make informed decisions in PHP development.
This talk is aimed at encouraging a more independent approach to using PHP frameworks, moving towards a more flexible and future-proof approach to PHP development.
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...DanBrown980551
Do you want to learn how to model and simulate an electrical network from scratch in under an hour?
Then welcome to this PowSyBl workshop, hosted by Rte, the French Transmission System Operator (TSO)!
During the webinar, you will discover the PowSyBl ecosystem as well as handle and study an electrical network through an interactive Python notebook.
PowSyBl is an open source project hosted by LF Energy, which offers a comprehensive set of features for electrical grid modelling and simulation. Among other advanced features, PowSyBl provides:
- A fully editable and extendable library for grid component modelling;
- Visualization tools to display your network;
- Grid simulation tools, such as power flows, security analyses (with or without remedial actions) and sensitivity analyses;
The framework is mostly written in Java, with a Python binding so that Python developers can access PowSyBl functionalities as well.
What you will learn during the webinar:
- For beginners: discover PowSyBl's functionalities through a quick general presentation and the notebook, without needing any expert coding skills;
- For advanced developers: master the skills to efficiently apply PowSyBl functionalities to your real-world scenarios.
"Impact of front-end architecture on development cost", Viktor TurskyiFwdays
I have heard many times that architecture is not important for the front-end. Also, many times I have seen how developers implement features on the front-end just following the standard rules for a framework and think that this is enough to successfully launch the project, and then the project fails. How to prevent this and what approach to choose? I have launched dozens of complex projects and during the talk we will analyze which approaches have worked for me and which have not.
State of ICS and IoT Cyber Threat Landscape Report 2024 previewPrayukth K V
The IoT and OT threat landscape report has been prepared by the Threat Research Team at Sectrio using data from Sectrio, cyber threat intelligence farming facilities spread across over 85 cities around the world. In addition, Sectrio also runs AI-based advanced threat and payload engagement facilities that serve as sinks to attract and engage sophisticated threat actors, and newer malware including new variants and latent threats that are at an earlier stage of development.
The latest edition of the OT/ICS and IoT security Threat Landscape Report 2024 also covers:
State of global ICS asset and network exposure
Sectoral targets and attacks as well as the cost of ransom
Global APT activity, AI usage, actor and tactic profiles, and implications
Rise in volumes of AI-powered cyberattacks
Major cyber events in 2024
Malware and malicious payload trends
Cyberattack types and targets
Vulnerability exploit attempts on CVEs
Attacks on counties – USA
Expansion of bot farms – how, where, and why
In-depth analysis of the cyber threat landscape across North America, South America, Europe, APAC, and the Middle East
Why are attacks on smart factories rising?
Cyber risk predictions
Axis of attacks – Europe
Systemic attacks in the Middle East
Download the full report from here:
https://sectrio.com/resources/ot-threat-landscape-reports/sectrio-releases-ot-ics-and-iot-security-threat-landscape-report-2024/
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Tobias Schneck
As AI technology is pushing into IT I was wondering myself, as an “infrastructure container kubernetes guy”, how get this fancy AI technology get managed from an infrastructure operational view? Is it possible to apply our lovely cloud native principals as well? What benefit’s both technologies could bring to each other?
Let me take this questions and provide you a short journey through existing deployment models and use cases for AI software. On practical examples, we discuss what cloud/on-premise strategy we may need for applying it to our own infrastructure to get it to work from an enterprise perspective. I want to give an overview about infrastructure requirements and technologies, what could be beneficial or limiting your AI use cases in an enterprise environment. An interactive Demo will give you some insides, what approaches I got already working for real.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...James Anderson
Effective Application Security in Software Delivery lifecycle using Deployment Firewall and DBOM
The modern software delivery process (or the CI/CD process) includes many tools, distributed teams, open-source code, and cloud platforms. Constant focus on speed to release software to market, along with the traditional slow and manual security checks has caused gaps in continuous security as an important piece in the software supply chain. Today organizations feel more susceptible to external and internal cyber threats due to the vast attack surface in their applications supply chain and the lack of end-to-end governance and risk management.
The software team must secure its software delivery process to avoid vulnerability and security breaches. This needs to be achieved with existing tool chains and without extensive rework of the delivery processes. This talk will present strategies and techniques for providing visibility into the true risk of the existing vulnerabilities, preventing the introduction of security issues in the software, resolving vulnerabilities in production environments quickly, and capturing the deployment bill of materials (DBOM).
Speakers:
Bob Boule
Robert Boule is a technology enthusiast with PASSION for technology and making things work along with a knack for helping others understand how things work. He comes with around 20 years of solution engineering experience in application security, software continuous delivery, and SaaS platforms. He is known for his dynamic presentations in CI/CD and application security integrated in software delivery lifecycle.
Gopinath Rebala
Gopinath Rebala is the CTO of OpsMx, where he has overall responsibility for the machine learning and data processing architectures for Secure Software Delivery. Gopi also has a strong connection with our customers, leading design and architecture for strategic implementations. Gopi is a frequent speaker and well-known leader in continuous delivery and integrating security into software delivery.
Neuro-symbolic is not enough, we need neuro-*semantic*Frank van Harmelen
Neuro-symbolic (NeSy) AI is on the rise. However, simply machine learning on just any symbolic structure is not sufficient to really harvest the gains of NeSy. These will only be gained when the symbolic structures have an actual semantics. I give an operational definition of semantics as “predictable inference”.
All of this illustrated with link prediction over knowledge graphs, but the argument is general.
Key Trends Shaping the Future of Infrastructure.pdfCheryl Hung
Keynote at DIGIT West Expo, Glasgow on 29 May 2024.
Cheryl Hung, ochery.com
Sr Director, Infrastructure Ecosystem, Arm.
The key trends across hardware, cloud and open-source; exploring how these areas are likely to mature and develop over the short and long-term, and then considering how organisations can position themselves to adapt and thrive.
Essentials of Automations: Optimizing FME Workflows with ParametersSafe Software
Are you looking to streamline your workflows and boost your projects’ efficiency? Do you find yourself searching for ways to add flexibility and control over your FME workflows? If so, you’re in the right place.
Join us for an insightful dive into the world of FME parameters, a critical element in optimizing workflow efficiency. This webinar marks the beginning of our three-part “Essentials of Automation” series. This first webinar is designed to equip you with the knowledge and skills to utilize parameters effectively: enhancing the flexibility, maintainability, and user control of your FME projects.
Here’s what you’ll gain:
- Essentials of FME Parameters: Understand the pivotal role of parameters, including Reader/Writer, Transformer, User, and FME Flow categories. Discover how they are the key to unlocking automation and optimization within your workflows.
- Practical Applications in FME Form: Delve into key user parameter types including choice, connections, and file URLs. Allow users to control how a workflow runs, making your workflows more reusable. Learn to import values and deliver the best user experience for your workflows while enhancing accuracy.
- Optimization Strategies in FME Flow: Explore the creation and strategic deployment of parameters in FME Flow, including the use of deployment and geometry parameters, to maximize workflow efficiency.
- Pro Tips for Success: Gain insights on parameterizing connections and leveraging new features like Conditional Visibility for clarity and simplicity.
We’ll wrap up with a glimpse into future webinars, followed by a Q&A session to address your specific questions surrounding this topic.
Don’t miss this opportunity to elevate your FME expertise and drive your projects to new heights of efficiency.
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
1. 85
Connection Solutions
www.ehawke.comUPD 141114
Group II Cable Glands
Flameproof, Increased Safety, Dust Protection
Class - Zones - Divisions
Certified ATEX / IECEx / c CSA us
Technical Data
ATEX/IECEx
Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust
Extb IIIC Db II 2 GD.
Certificate No’s: Baseefa06ATEX0056X and IECEx BAS 06.0013X.
Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas
Groups IIA, IIB and IIC.
Construction and Test Standards: IEC/EN 60079-0, IEC/EN
60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.
Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days)
to IEC/EN 60529 and NEMA 4X.
Deluge Protection to DTS01.
Operating Temperature Range: -60°C to +100°C.
Assembly Instruction Sheet: AI 310.
Features
Provides a cable retention seal onto the cables outer sheath.
When used in Increased Safety applications, this cable gland
may be used with braided cable where the braid and the
cables outer sheath pass into the enclosure. The braid must be
suitably terminated into the enclosure.
Provides female running coupler for cable gland or conduit
entry.
Manufactured in Brass (standard), Nickel Plated Brass, 316
Stainless Steel or Aluminium.
Brass NPT entries are nickel plated as standard.
Application
Outdoor or indoor use.
For use with non-armoured elastomer and plastic
insulated cables installed in conduit.
See technical section for installation rules and regulations.
¹ Smaller value is applicable when selecting reduced NPT male entry option.
² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter.
CABLE GLAND SELECTION TABLE
Size
Ref.
Entry Thread Size 'F'
Cable Acceptance Details
'G'
Hexagon DimensionsMale Female
Metric
NPT *
Standard or
Option
Metric
NPT #
Standard or
Option
Outer Sheath 'B'
Standard Seal Alternative Seal (S) Across
Flats
Across
CornersMin. Max. Min. Max.
Os M20² ½" M20 - 3.2 8.0 - - 54.5 24.0 26.5
O M20² ½" M20 - 6.5 11.9 - - 54.5 24.0 26.5
A M20 ¾" or ½" M20 - 10.0 14.3 9.0 13.4 56.4 30.0 32.5
B M25 1" or ¾" M25 - 13.0 20.2 9.5 15.4 48.2 36.0 39.5
C M32 1¼" or 1" M32 - 19.0 26.5 15.5 21.2 61.6 46.0 50.5
C2 M40 1 ½" or 1¼" M40 - 25.0 32.5 22.0 28.0 64.6 55.0 60.6
D M50 2" or 1 ½ " M50 - 31.5 44.4/42.3¹ 27.5 34.8 83.2 65.0 70.8
E M63 2 ½" or 2" M63 - 42.5 56.3/54.3¹ 39.0 46.5 83.2 80.0 88.0
F M75 3" or 2 ½" M75 - 54.5 68.2/65.3 ¹ 49.5 58.3 86.4 95.0 104.0
'T' — All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard.
Ordering Information
Format for ordering is as follows:
Alternative Seal (S), add suffix S to ordering information.
Cable Gland Type Size Thread Material (Optional)
501/414 C M32 Brass S
501/414 C 1 ¼" NPT Brass S
501/414
'G''T'
'F'
ø'B'
Alternativecertificationoptionsavailable:
c CSA us
Flameproof AExd IIC Gb, Increased Safety AExe IIC Gb and Dust
AExtD Zone 21.
Explosion-proof Class 1 Division 2 Groups ABCD, Class II
Division 2 Groups EFG, Class III.
Certificate No’s: CSA1015065 for Marine Shipboard Cable.
Construction and Test Standards: UL 60079-0, UL 60079-1, UL
60079-7, ISA 60079-31, CSA 22.2 No: 60079-0, CSA 22.2 No:
60079-1, CSA 22.2 No: 60079-7, CSA 22.2 No: 60079-31, UL 2225