The document is a 2009 catalogue for Normist pumps that includes:
1) Descriptions of 27 different pump models ranging from 1 to 170 LPM and powered by direct drive or various belt drive types.
2) Specifications for each pump including flow rate, pressure, motor power, dimensions, and weight.
3) A table showing the number of nozzles each pump can drive at 70 bar pressure for different nozzle sizes.
4) A brief mention of control boxes available for the misting pumps.
Maintenance instructions for power transformersLucian Lazar
This document provides maintenance instructions and schedules for power transformers. It lists items to inspect on hourly, daily, quarterly, half-yearly, yearly, and 5-10 yearly schedules. These include ambient temperature, winding temperature, oil temperature, load, voltage, oil levels, bushings, breather, cooler fan operation, gasket joints, relays, painting, and earth resistance. It describes what to check for each item and the required actions if inspections show unsatisfactory conditions, such as low oil levels, cracks, rust, or abnormal operation. The goal is to ensure temperatures, oil quality, components, and performance remain within specified limits through regular inspections and maintenance.
1. The document describes a Continues Catalytic Reformer (CCR) unit that has two sections: Naphtha Hydro Treating (NHT) and Platforming.
2. The NHT section produces light and heavy naphtha, while the Platforming section produces hydrogen, high octane reformate, and low octane reformate.
3. The document provides details on the equipment in the CCR unit like heaters, reactors, strippers, splitters, and treaters along with operating parameters such as temperatures, pressures, flow rates.
Working parameters
Specifications
Operation Parameters
Alarms and actions
Oil pumps and lines
Regulators and Valves
Ejectors
Air compressors
Pump house
Steam header
Feed water System
Operating Parameters
Fuel Gas path
Ash content vs fuel efficiency
Operating alarms
operating instruments on panel
This document provides specifications for an oil tanker. It describes the tanker as a Suezmax oil tanker with a capacity of 166,300 deadweight tons. Key details include that it was built in 2003-2004 by Shipyard Brodosplit and has a single screw diesel engine, longitudinal bulkhead, bulbous bow, and transom stern. It can handle three grades of cargo simultaneously and has cargo and slop tanks, as well as double bottom/side tanks and peak tanks for segregated ballast.
The document summarizes the fuel oil and drainage systems at APML. It describes the two types of fuel oil used - light diesel oil (LDO) and heavy fuel oil (HFO) - and provides details on their properties, storage, transfer, and boiler systems. It also outlines the drainage system for collecting and separating oil and water from the fuel systems.
The document discusses transformer oil analysis. It describes the key components of a transformer's insulating system as the oil and paper. Transformer oil classifications include naphthenic oil, paraffinic oil, and silicon oil. The document outlines specifications for new and in-service transformer oils according to various standards. It explains the importance of various oil properties like appearance, acidity, dielectric strength, and oxidation stability and how they impact transformer performance and life.
Industrial and professional cleaning equipmentsAdelina Cirstea
The document is a catalog listing specifications for various high-pressure cleaner models from Lavor PRO. It provides details like operating pressure, delivery rate, absorbed power, RPM, voltage, weight and packaging for each model. The models are organized by series and include options like horizontal and vertical construction as well as axial and crankshaft pump designs.
Maintenance instructions for power transformersLucian Lazar
This document provides maintenance instructions and schedules for power transformers. It lists items to inspect on hourly, daily, quarterly, half-yearly, yearly, and 5-10 yearly schedules. These include ambient temperature, winding temperature, oil temperature, load, voltage, oil levels, bushings, breather, cooler fan operation, gasket joints, relays, painting, and earth resistance. It describes what to check for each item and the required actions if inspections show unsatisfactory conditions, such as low oil levels, cracks, rust, or abnormal operation. The goal is to ensure temperatures, oil quality, components, and performance remain within specified limits through regular inspections and maintenance.
1. The document describes a Continues Catalytic Reformer (CCR) unit that has two sections: Naphtha Hydro Treating (NHT) and Platforming.
2. The NHT section produces light and heavy naphtha, while the Platforming section produces hydrogen, high octane reformate, and low octane reformate.
3. The document provides details on the equipment in the CCR unit like heaters, reactors, strippers, splitters, and treaters along with operating parameters such as temperatures, pressures, flow rates.
Working parameters
Specifications
Operation Parameters
Alarms and actions
Oil pumps and lines
Regulators and Valves
Ejectors
Air compressors
Pump house
Steam header
Feed water System
Operating Parameters
Fuel Gas path
Ash content vs fuel efficiency
Operating alarms
operating instruments on panel
This document provides specifications for an oil tanker. It describes the tanker as a Suezmax oil tanker with a capacity of 166,300 deadweight tons. Key details include that it was built in 2003-2004 by Shipyard Brodosplit and has a single screw diesel engine, longitudinal bulkhead, bulbous bow, and transom stern. It can handle three grades of cargo simultaneously and has cargo and slop tanks, as well as double bottom/side tanks and peak tanks for segregated ballast.
The document summarizes the fuel oil and drainage systems at APML. It describes the two types of fuel oil used - light diesel oil (LDO) and heavy fuel oil (HFO) - and provides details on their properties, storage, transfer, and boiler systems. It also outlines the drainage system for collecting and separating oil and water from the fuel systems.
The document discusses transformer oil analysis. It describes the key components of a transformer's insulating system as the oil and paper. Transformer oil classifications include naphthenic oil, paraffinic oil, and silicon oil. The document outlines specifications for new and in-service transformer oils according to various standards. It explains the importance of various oil properties like appearance, acidity, dielectric strength, and oxidation stability and how they impact transformer performance and life.
Industrial and professional cleaning equipmentsAdelina Cirstea
The document is a catalog listing specifications for various high-pressure cleaner models from Lavor PRO. It provides details like operating pressure, delivery rate, absorbed power, RPM, voltage, weight and packaging for each model. The models are organized by series and include options like horizontal and vertical construction as well as axial and crankshaft pump designs.
The TLC is a temperature limit controller that connects to air conditioning systems to limit cooling and heating temperatures, saving energy. It has adjustable temperature limits for cooling and heating that can turn the compressor on and off. It is compact, easy to install, and allows significant energy savings without impacting user convenience or requiring modifications to existing HVAC systems.
M6000 t1-t2-an-air-conditione-controllererdinc klima
The M6000-T1-T2-AN is a multi-stage display controller with 6 individually programmable outputs and inputs for 2 temperature sensors. It allows users to customize their HVAC control system by setting parameters for each output like temperature set points, differentials, logic, and delays. The controller can be used for applications with multiple cooling and heating stages controlled by temperature or analog sensors. It provides an easy to program solution for complex HVAC control needs.
The Meitav-tec FCC_01 Free Cooling Controller is a wall mount thermostat that saves energy by taking advantage of cooler outdoor air temperatures. It has an open/auto/close switch to control a damper, fan, or window. Sensors monitor indoor and outdoor temperatures, and it will open the damper or window when outside air is cooler than inside by the default 1°C difference. Accessories include indoor and outdoor temperature sensors and a decorative back plate.
The EC-300 is an energy controller that turns off HVAC and lighting systems when rooms are unoccupied to save energy in hotels or offices. It detects presence using an infrared occupancy sensor and optional contact inputs. It can be configured for either hotel or office use and has options for compressor delay, temperature limits, and window switch settings. It provides easy installation and energy savings without reducing user convenience.
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalarerdinc klima
This document provides information on 2-way and 3-way zone valves from the V2BM and V3BM series. It summarizes the main features, descriptions, uses, functions, hydraulics, technical characteristics, design features, flow rate/pressure drop chart, and overall dimensions of the valves. The valves are available in sizes from 1/2" to 2" and are made of bronze with a globe plug. They are suitable to be used with M400 or M800 series actuators on heating and cooling systems.
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisierdinc klima
Rotary drives are suitable for water applications such as industrial water and process media. They include 2-way and 3-way ball valves with female threading in sizes from 1/2" to 2". The ball valves and actuators must be ordered separately. All components meet relevant DIN and CE standards.
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisierdinc klima
This document discusses rotary drives and ball valves for water applications. It provides order codes for actuators and ball valves, including information on configurations, control signals, feedback signals, options, and supply voltages for actuators. It also summarizes ball valve types 224 and 235 and provides details on 2-way ball valves with female and male threads. Actuators and ball valves are used for applications involving drinking water, industrial water, and other process media.
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisierdinc klima
The document describes the ESBE Series ALA200 linear motorized valve actuator. The actuator is suitable for ESBE control valves with a stroke of 10-20mm and provides up to 750N of force. It can be controlled via a 3-point signal of 24V or 230V AC or a proportional 0-10V, 2-10V, 0-20mA or 4-20mA signal with a 24V AC/DC supply. The actuator is simple to install directly on ESBE control valves and operates the valve linearly in response to control signals.
Duyar Elemanlar St fr ex-donma-termostaterdinc klima
The document is a data sheet that describes the ST-FRE range of capillary frost thermostats. The thermostats provide a switch output based on the average temperature detected along a 6 meter capillary sensor to prevent icing in air ducts. Key features include universal mounting, adjustable temperature setpoints, and IP44 or IP65 housing. Specifications include a control range of -30 to +10°C, differential settings of 2-16°C, and switch ratings up to 230Vac.
Duyar Elemanlar Sensi co px300-co-sensorerdinc klima
SensiCO PX 300 is a reliable sensor for measuring carbon monoxide (CO) concentration in locations like parking garages. As CO is odorless and dangerous, the sensor is important for total protection from CO poisoning. When CO levels exceed 50 PPM, the sensor activates ventilation and sends an alarm. The electro-chemical sensor measures CO concentration from 0-300 PPM, has a response time under 60 seconds, and connects via a 4-20 mA signal to control systems.
The document provides information about Gruner AG actuator Type 238 for dampers. The Type 238 is an actuator with spring return and torque of 15 Nm. It is suitable for applications involving room ventilation techniques and VAV valves. The Type 238 has technical characteristics including On/Off and continuous control, power supply of 24 VAC/DC or 230 VAC, and optional auxiliary switches. It provides positioning of dampers or valves in ventilation systems.
The TLC is a temperature limit controller that connects to air conditioning systems to limit cooling and heating temperatures, saving energy. It has adjustable temperature limits for cooling and heating that can turn the compressor on and off. It is compact, easy to install, and allows significant energy savings without impacting user convenience or requiring modifications to existing HVAC systems.
M6000 t1-t2-an-air-conditione-controllererdinc klima
The M6000-T1-T2-AN is a multi-stage display controller with 6 individually programmable outputs and inputs for 2 temperature sensors. It allows users to customize their HVAC control system by setting parameters for each output like temperature set points, differentials, logic, and delays. The controller can be used for applications with multiple cooling and heating stages controlled by temperature or analog sensors. It provides an easy to program solution for complex HVAC control needs.
The Meitav-tec FCC_01 Free Cooling Controller is a wall mount thermostat that saves energy by taking advantage of cooler outdoor air temperatures. It has an open/auto/close switch to control a damper, fan, or window. Sensors monitor indoor and outdoor temperatures, and it will open the damper or window when outside air is cooler than inside by the default 1°C difference. Accessories include indoor and outdoor temperature sensors and a decorative back plate.
The EC-300 is an energy controller that turns off HVAC and lighting systems when rooms are unoccupied to save energy in hotels or offices. It detects presence using an infrared occupancy sensor and optional contact inputs. It can be configured for either hotel or office use and has options for compressor delay, temperature limits, and window switch settings. It provides easy installation and energy savings without reducing user convenience.
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalarerdinc klima
This document provides information on 2-way and 3-way zone valves from the V2BM and V3BM series. It summarizes the main features, descriptions, uses, functions, hydraulics, technical characteristics, design features, flow rate/pressure drop chart, and overall dimensions of the valves. The valves are available in sizes from 1/2" to 2" and are made of bronze with a globe plug. They are suitable to be used with M400 or M800 series actuators on heating and cooling systems.
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisierdinc klima
Rotary drives are suitable for water applications such as industrial water and process media. They include 2-way and 3-way ball valves with female threading in sizes from 1/2" to 2". The ball valves and actuators must be ordered separately. All components meet relevant DIN and CE standards.
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisierdinc klima
This document discusses rotary drives and ball valves for water applications. It provides order codes for actuators and ball valves, including information on configurations, control signals, feedback signals, options, and supply voltages for actuators. It also summarizes ball valve types 224 and 235 and provides details on 2-way ball valves with female and male threads. Actuators and ball valves are used for applications involving drinking water, industrial water, and other process media.
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisierdinc klima
The document describes the ESBE Series ALA200 linear motorized valve actuator. The actuator is suitable for ESBE control valves with a stroke of 10-20mm and provides up to 750N of force. It can be controlled via a 3-point signal of 24V or 230V AC or a proportional 0-10V, 2-10V, 0-20mA or 4-20mA signal with a 24V AC/DC supply. The actuator is simple to install directly on ESBE control valves and operates the valve linearly in response to control signals.
Duyar Elemanlar St fr ex-donma-termostaterdinc klima
The document is a data sheet that describes the ST-FRE range of capillary frost thermostats. The thermostats provide a switch output based on the average temperature detected along a 6 meter capillary sensor to prevent icing in air ducts. Key features include universal mounting, adjustable temperature setpoints, and IP44 or IP65 housing. Specifications include a control range of -30 to +10°C, differential settings of 2-16°C, and switch ratings up to 230Vac.
Duyar Elemanlar Sensi co px300-co-sensorerdinc klima
SensiCO PX 300 is a reliable sensor for measuring carbon monoxide (CO) concentration in locations like parking garages. As CO is odorless and dangerous, the sensor is important for total protection from CO poisoning. When CO levels exceed 50 PPM, the sensor activates ventilation and sends an alarm. The electro-chemical sensor measures CO concentration from 0-300 PPM, has a response time under 60 seconds, and connects via a 4-20 mA signal to control systems.
The document provides information about Gruner AG actuator Type 238 for dampers. The Type 238 is an actuator with spring return and torque of 15 Nm. It is suitable for applications involving room ventilation techniques and VAV valves. The Type 238 has technical characteristics including On/Off and continuous control, power supply of 24 VAC/DC or 230 VAC, and optional auxiliary switches. It provides positioning of dampers or valves in ventilation systems.
2. pumps
AJ series
AJ1 & AJ2 & AJ4 & AJ9
1, 2 , 4 and 9 LPM
70 BAR
Piston pump
Direct Drive
24 / 25 / 27 / 29 Kg
AT series
AT15
15 LPM
70 BAR
Piston pump
Direct Drive
36 & 38 & 40 Kg
N series
AJ2N & AJ4N
2 and 4 LPM 70 BAR
Piston pump
Very low noise
Motor and pump protection circuit
Programmable timer
Drain system
40 And 43 Kg
1
3. pumps
AR series
NEW NEW
AR1 AR1C & AR2C & AR4C
1 LPM 70 BAR 1, 2 ve 4 LPM 70 BAR
Axial pump Axial pump
Direct Drive Direct Drive
13.4 Kg 22.6 Kg
KJ series
KJ4C & KJ8C
4, 8 LPM
70 BAR
KJ4 & KJ8 Piston pump
Very low noise
4 , 8 LPM
Motor and pump protection circuit
70 BAR Programmable timer
Piston pump Drain system
Pulley Drive Radio controlled ON-OFF function
37 and 40 Kg 2.5 m. connection cable with connector on both ends
KM series
NEW
KM12C
12 LPM 70 BAR
Piston pump
Pulley Drive
43 Kg.
2
4. pumps
CAT PUMP series
2SF5 2SF10
5 LPM 70 BAR 10 LPM 70 BAR
Piston pump Piston pump
Direct Drive Direct Drive
39 Kg 41 Kg
NEW
NORMATIC 2SF2-10 3CP16
2-10 LPM 70 BAR 16 LPM 70 BAR
Piston pump Piston pump
Direct Drive Double Belt Drive
52 Kg 58 Kg
5CP23 NORMATIC 5CP 10-25
23 LPM 70 BAR 10-25 LPM 70 BAR
Piston pump Piston pump
Double Belt Drive Direct GB Drive
59 Kg 69 Kg
3
5. pumps
CAT PUMP Series
15CP20-45
20-45 LPM 70 BAR
Piston pump
Triple Belt Drive
120+25 Kg
NEW
15CP45 15CP68
45 LPM 70 BAR 68 LPM 70 BAR
Piston pump Piston pump
Triple Belt Drive Trigger Belt Drive
113 Kg 124 Kg
NEW NEW
35CP87 3545CP170
87 LPM 70 BAR 170 LPM 70 BAR
Piston pump Piston pump
Trigger Belt Drive Trigger Belt Drive
235 Kg 335 Kg
4
6. pumps
professional series
ATM 20 ATT 24
20 LPM 70 BAR 24 LPM 70 BAR
Piston pump Piston pump
Belt Drive Double Belt Drive
60 Kg 95 Kg
KKV36 RBL 50
36 LPM 70 BAR 50 LPM 70 BAR
Piston pump Piston Pump
Double Belt Drive Triple Belt Drive
111 Kg 120 Kg
NEW
CK 95
95 LPM 70 BAR
Piston Pump
Flex Coupling
226 Kg
5
7. NORMIST HIGH PRESSURE PUMP UNITS
Flow Dimension Weight
Pump Flow Motor Volt
Pres. GPM Drive A dB With With
Unit LPM HP Phase
Wooden Box Box
NEW AR1 70 Bar 1 0.25 Direct 1 220-1 5 72 40x40x36 21
NEW AR1C 70 Bar 1 0.25 Direct 1 220-1 5 71 55x46x42 32
NEW AR2C 70 Bar 2 0.5 Direct 1 220-1 5 71 55x46x42 32
NEW AR4C 70 Bar 4 1 Direct 1 220-1 5 72 55x46x42 32
AJI 70 Bar 1 0.25 Direct 1 220-1 5.5 74 55x46x49 32
AJ2 70 Bar 2 0.5 Direct 1 220-1 5.5 76 55x46x49 32
AJ4 70 Bar 4 1 Direct 1½ 220-1 8 76 55x46x49 34
AJ9 70 Bar 9 2.3 Direct 2 220-1 10.5 77 55x46x49 36
AJ2N 70 Bar 2 0.5 Direct 1 220-1 5.5 68 62x48x48 50
AJ4N 70 Bar 4 1 Direct 1½ 220-1 8 69 62x48x48 52
AT15 70 Bar 15 4 Direct 4 380-3 6.5 82 72x46x48 46
KJ4 70 Bar 4 1.3 Pulley 1 220-1 5 78 62x44x45 45
KJ8 70 Bar 8 2.1 Pulley 1½ 220-1 8 80 62x44x45 46
KJ4C 70 Bar 4 1.3 Pulley 1 220-1 5 77 65x65x45 62
KJ8C 70 Bar 8 2.1 Pulley 1½ 220-1 8 77 65x65x45 63
2SF5 70 Bar 5 1.3 Direct 1½ 220-1 6 75 72x46x38 49
2SF10 70 Bar 10 2.6 Direct 3 220-1 10 83 72x46x38 51
NM 2-10 70 Bar 2 / 10 0.5 to 2.65 Direct 2 380-3 10 67/75 70x70x48 67
NM 10-25 70 Bar 10 / 25 2.6 to 6.6 Direct GB 4 380-3 8 85/89 95x55x75 88
KM12 70 Bar 12 3.1 Pulley 4 380-3 6 82 72x48x48 60
NEW KM12C 70 Bar 12 3 Pulley 4 380-3 6 82 70x70x48 78
NEW 3CP16 70 Bar 16 4 2x Pulley 5.5 380-3 8.8 87 90x52x54 70
ATM20 70 Bar 20 5.3 Pulley 5½ 380-3 7.5 86 90x52x54 75
5CP23 70 Bar 23 6.1 2X Pulley 5½ 380-3 7 88 90x52x54 75
ATT24 70 Bar 24 6.4 2X Pulley 5½ 380-3 7 88 94x64x60 115
KKV36 70 Bar 36 9.5 2X Pulley 10 380-3 12 93 94x64x60 124
15CP45 70 Bar 45 12 3X Pulley 10 380-3 12 96 94x64x60 132
15CP20-45 70 Bar 20/45 5.2 to 12 3X Pulley 10 380-3 12 96 94x64x60 132
RBL50 70 Bar 50 13.2 3X Pulley 15 380-3 14 93 94x64x60 132
NEW 15CP68 70 Bar 68 17.9 Trigger Pulley 15 380-3 21 97 110x75x55 146
NEW 35CP87 70 Bar 87 23 Trigger Pulley 20½ 380-3 29.5 97 150x95x64 255
NEW CK95 70 Bar 95 25 Flex Coupling 30 380-3 45 96 150x95x64 250
pumps
6
NEW 3545CP170 70 Bar 170 45 Trigger Pulley 40 380-3 56 97 150x95x64 270
10. controls
Measuring
• Controls humidity or temperature
humidistat
• Microprocessor controlled.
• EPROM Memory
• External humidity sensor.
• Connection length to sensor box up to 100 meters.
• Monitoring and setting of humidity is 5/95 % RH
• Accuracy of measurement ±3%RH
• 1 ON/OFF output to control a humidifier
Pressure Pressure High pressure Low pressure
switch regulator gauge gauge
(160 bar) (10 bar)
Flexible nozzle extention adaptor
Total lenght
15 cm.
9
11. filters
Filters
10’’ Single filter unit 10’’ Double filter unit
10” housing, 1 filter 2x10” housings, 2 filters
10 micron 25 micron
0305005 Max flow 25 liters per minute Max flow 25 liters per minute
0305006
Max working pressure 6 Bar Max working pressure 6 Bar
Weight 2.2 kg Weight 4.1 kg
10’’ Triple filter group 20’’ Triple filter unit
3x10” housings, 3 filters 3x20” housings, 3 filters
5,10,25 microns 5,10,25 microns
0305001 Max flow 25 liters per minute Max flow 45 liters per minute
Max working pressure 6 Bar Max working pressure 6 Bar
Entry and output size is slip-lok 12 mm 0305002 Entry and output size is 20 mm
Weight 5.7 kg Weight 7.8 kg
20’’ Large double filter unit 20’’ Large double filter unit X2
2x20” large housings, 2 filters 4x20” large housings, 4 filters
5-20, 20 microns 5-20, 20 microns
Max flow 55 liters per minute Max flow 110 liters per minute
Max working pressure 6 Bar Max working pressure 6 Bar
Entry and output size is 24 mm Entry and output size is 40 mm
0305041 0305042
Weight 12 kg Weight 31 kg
10
12. tubing
filters
Filters and filter equipments
High pressure in line filters High pressure in line mini filters
3/8” Slip-lok connection
1/2” Slip-lok connection
3/16” Slip-lok connection
3/8” Slip-lok connection
• A must for all misting installations
• No more plugged nozzles
• Cleanable 100 mesh SS filter element for 15 and 30 LPM
• 15 and 30 LPM filter types.
• All Stainless Steel
• Tested at 250 Bar.
Dosing pump
Parfuming the air is also possible by addition of our dosing pump kit.
11
13. tubing
304 & 316 quality stainless steel tubing
Working pressure 150 BAR.Prefabricated misting lines.
3000 mm tubing for nozzle spacing 3x1000 mm & 4x750 mm & 6x500 mm
6000 mm tubing for nozzle spacing 6x1000 mm & 8x750 mm & 12x500 mm
M5
10-24 UNC
12-24 UNC Ø 12x1.5 mm
3000 & 6000 mm
nylon tubing
• Polyamide 12
• 3% UV treated
• Working pressure 70 bar
• Burst pressure 140 bar
• Sizes available: black for 5/16” and 1/2”. Black, white and green
for 3/8” and 3/16”(5mm)
• 3/8” tubing available in pre-cut straight 75 cm. and 300 cm. length.
• 1/2” tubing available in pre-cut straight 400 cm. length.
• 5/16” and 3/8” tubing in 100 m. roll.
• 1/2” tubing in 50 m. roll.
• 3/16” (5 mm) tubing in 200 m. roll.
• Stainless steel clamps are available for all sizes. Black and white color.
clamps clips
Stainless steel clamp for Plastic clips for Plastic clips for
3/16”, 5/16”, 3/8” ve 1/2” tubing 3/8” ve 1/2” tubing 3/8” and 1/2” tubing
12
14. tubing
Pressure loss in nylon pipes due to length
PRESSURE LOSS IN 30m 5mm NYLON PIPE / FLOW 1 AND 1.5 LITER PER MINUTE
75
70
65
60
55
50
PRESSURE / BAR
45 1 Liter
40
35
30
25
20
15 1.5 Liter
10
5
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
TUBE LENGTH / METER
PRESSURE LOSS IN 75m 3/8" NYLON PIPE / FLOW 3 AND 5 LITER PER MINUTE
75
70
65
60
55 3 Liter
50
PRESSURE / BAR
45
40
35
30 5 Liter
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
TUBE LENGTH / METER
PRESSURE LOSS IN 75m 1/2" NYLON PIPE / FLOW 10 AND 15 LITER PER MINUTE
75
70
65
60
55
50 10 Liter
PRESSURE / BAR
45
40
35
30 15 Liter
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
TUBE LENGTH / METER
13
15. tubing
Pressure loss in stainless steel pipes due to length
PRESSURE LOSS IN 75m 12mm SS PIPE / FLOW 15 AND 25 LITER PER MINUTE
75
70
65
60
55
50
PRESSURE / BAR
15 Liter
45
40
35
30
25
20
15
10 25 Liter
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
TUBE LENGTH / METER
PRESSURE LOSS IN 75m 16mm SS PIPE / FLOW 25 AND 50 LITER PER MINUTE
90
85
80
75
70 25 Liter
65
60
PRESSURE / BAR
55
50
45 50 Liter
40
35
30
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
TUBE LENGTH / METER
PRESSURE LOSS IN 150m 20mm SS PIPE / FLOW 70 AND 100 LITER PER MINUTE
100
90
80
70
PRESSURE / BAR
60 70 Liter
50
40
30
100 Liter
20
10
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
TUBE LENGTH / METER
14
16. Outdoor Patio
cooling cooling
Dust
Greenhouses
control
Odor Industrial
control humidification
Animal
Attractions
cooling
NOR ELEKTRONIK LTD
E-mail : info@normist-tr.com
Website : www.normist-tr.com