meitav-tec       M6000-T1-T2-AN                           M6000 (12V)       PS104                                         ...
meitav-tec                                                                                                                ...
meitav-tec                                                               M6000-T1-T2-AN            Sample Application     ...
meitav-tec                                                      M6000-T1-T2-AN             Dimensions                     ...
Upcoming SlideShare
Loading in …5
×

M6000 t1-t2-an-air-conditione-controller

472 views

Published on

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
472
On SlideShare
0
From Embeds
0
Number of Embeds
4
Actions
Shares
0
Downloads
3
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

M6000 t1-t2-an-air-conditione-controller

  1. 1. meitav-tec M6000-T1-T2-AN M6000 (12V) PS104 Multi-stage display controller with individually programmable outputs, 2 outputs for Fan, 2 temperature sensors and Fault. General Features The M6000-T1-T2-AN controller is the • Main Supply - 230Vac with power supply. best multi-stage display controller on • Range temperature from 0°C-65°C the market today. As opposed to many • Range set point for each output 0°C-60°C complicated units, the M6000-T1-T2-AN • 6 programmable outputs, each output makes it incredibly easy to pre-set corresponds to a stage- parameters that can be stages and all other parameters. This, set are: plus the 6 individually programmed - Set point outputs, gives users the unique ability - Input to operate by: Analog, T1 or T2 (2 to “custom-build” their entire HVAC different temperature sensors) – inputs may be control system. combined - Differential (∆T between stages) The M6000-T1-T2-AN offers the - Logic for output- COOL or HEAT following: Ex: Humidifier- If HEAT is selected, output will be • 6 outputs- fully programmable activated only if set point is HIGHER than actual • 2 outputs for On Indication (fan) humidity • Input for 2 temperature sensors to be - Compressor delay – Yes or No used separately for each output (Meitav- - All outputs have Random start tec sensors) • Analogue input can be set for different scales •Analog Inputs (0-10Vdc) to be used (0 to 100 as % or 0 to adjustable) separately for each output (humidity, • Fault input – Normally Open (all unit OFF) pressure, water flow, etc) The M6000-T1-T2-AN is suitable for even the largest of applications such as chillers and big air-handling units. File: M6000-T1-T2.PPTPg.1 www.meitavtec.com | Email: info@meitavtec.com | Tel: +972 (3) 962 6462 Rev. 1.1 Date: 16.03.06
  2. 2. meitav-tec M6000-T1-T2-AN Electrical Diagram – Connection to PS-104 On Return Air Sensor Return Air Sensor Indication Stages (Fan) Analog Input T2 (Option) T1 (Option) Main Input Out 1 (2A) Out 2 (2A) Out 3 (2A) Out 4 (2A) Out 6 (2A) Out 5 (2A) Out 7 (2A) Out 8 (2A) (Option) 230Vac 15 14 17 13 12 11 16 17 ~ 0 T1 T1 T2 T2 T3 T3 PS-104 2 3 21 4 5 6 1 22 7 8 9 10 20 13x0.5 12Vdc 10 20 1 2 3 4 5 6 7 8 22 21 9 M6000-T1-T2-AN Electrical Diagram – Connection to PS-104-DRY Temperature Sensor Temperature Sensor Dry Contact Outputs – Max 220Vac,6A Outdoor Coil Unit B Outdoor Coil Unit A Return Air Sensor On/Off Command On/Off Command Temp. Controller T1 (Option) Not Working Not Working Main Input High Temp. Low Temp. A/C Unit A A/C Unit A A/C Unit B A/C Unit B Not in use 230Vac Failure Alarm Alarm ~ 0 T1 T1 T2 T2 T3 T3 A8 B8 A3 B3 A7 B7 A1 B1 A2 B2 A4 B4 ‫ז‬ A5 B5 A6 B6 PS-104-DRY 22 21 1 2 3 4 5 6 7 8 9 10 20 12x0.5 12Vdc 10 20 1 2 3 4 5 6 7 8 22 21 9 M6000-T1-T2-AN File: M6000-T1-T2.PPTPg.2 www.meitavtec.com | Email: info@meitavtec.com | Tel: +972 (3) 962 6462 Rev. 1.1 Date: 16.03.06
  3. 3. meitav-tec M6000-T1-T2-AN Sample Application Air Handler with: • 2 stages of cool (compressors) • Outdoor Temperature Sensor • 2 stages of heat • Dehumidifier with stage cool 1 • Humidifier • Fresh Air damper based on outdoor temp. Configuration for Sample Application Stage/ System Control Logic Setting Remarks Output connection By Tset – 20 First stage of cool and Dehumidifier Cool 1 1 T1+Analog Cool An On – 55 With Time Delay (Td 1) (Compressor) An Off - 70 Differential 2˚C Second stage of cool to start on 25˚C Cool 2 With Time delay (Td 1) 2 T1 Cool Tset - 25 (Compressor) Differential 2˚C An On – 50 Humidifier set point 50% 3 Humidifier Analog - An Off - 40 With a dead band of 10% bellow First stage of Heat and reheat when Dehumidifier On 4 Heat 1 T1 Heat Tset - 25 No time delay (Td 0) Differential 2˚C This is for Freeze protection – based 5 Heat 2 T2 Heat Tset - 3 on outdoor temperature The fresh air damper will open only Fresh Air 6 T2 Heat Tset – 21 when the outdoor temperature will be Damper less than 21˚C This output will switch on the fan when 7 Fan for Cool On - - outputs 1 to 3 are active This output will switch on the fan when 8 Fan for Heat On - - outputs 4 to 6 are active File: M6000-T1-T2.PPTPg.3 www.meitavtec.com | Email: info@meitavtec.com | Tel: +972 (3) 962 6462 Rev. 1.1 Date: 16.03.06
  4. 4. meitav-tec M6000-T1-T2-AN Dimensions 15mm 53mm 15mm 38mm 45mm 43mm 40mm 30mm Specifications – M6000 Dimensions –PS104 Temperature Range 10°C ÷ 30°C Length 147 mm Weight 0.25 Kg Width 87 mm Scale °C Height 40 mm Color White Weight 0.368 Kg Accuracy 1°C Plastic PC/ABS Flammability UL94V-0 Temperature Input 50K@25°C Accessories Part Number Description PS-104 Power Supply PS-104-DRY Power Supply with dry contacts RS01 Temperature Sensor into decorative box TS01 Temperature Sensor - 80 cm Cable RS02 Average Temperature Sensor into decorative box RS03 Room Temperature Sensor ±3°C DT02 Duct Temperature Sensor File: M6000-T1-T2.PPTPg.4 www.meitavtec.com | Email: info@meitavtec.com | Tel: +972 (3) 962 6462 Rev. 1.1 Date: 16.03.06

×