Atlas cable cleats are designed to provide mechanical support and withstand short circuits for trefoil and single cable applications. They have a patented design that offers one bolt, two bolt, or framing channel fixing options. The cleats are manufactured from galvanized or stainless steel and include integral pads to protect cables during short circuits. They have passed various testing requirements for properties like axial movement, flame resistance, lateral load, and impact resistance according to the European standard for cable cleats.
The Rubber Chevron Springs product catalogue from GMT Rubber-Metal Technology. This product brochure features technical specifications and diagrams of a wide range of Rubber Chevron Springs available within the GMT range
Atlas cable cleats suit trefoil and single way cable applications where high levels of short circuit withstand are required.
As well as providing the cables with significant mechanical support, the unique patented Atlas cable cleat design provides a choice of one bolt, two bolt or framing channel fixing options.
Manufactured in stainless and galvanised steel all range taking Atlas cable cleats are supplied with a stainless steel top bolt to eliminate eddy currents.
To protect and cushion the cables during short circuit conditions the Atlas cable cleat comes with integral LSF Zero Halogen Polymeric pads.
Ellis Patents Atlas range taking cable cleats have been tested in accordance with the European Standard of "Cable Cleats for Electrical Installations" BS EN 50368 : 2003 - Ellis Patents are the global leader in the manufacture of quality and trusted single way, trefoil, quadrafoil and range taking cable cleats.
The Rubber Chevron Springs product catalogue from GMT Rubber-Metal Technology. This product brochure features technical specifications and diagrams of a wide range of Rubber Chevron Springs available within the GMT range
Atlas cable cleats suit trefoil and single way cable applications where high levels of short circuit withstand are required.
As well as providing the cables with significant mechanical support, the unique patented Atlas cable cleat design provides a choice of one bolt, two bolt or framing channel fixing options.
Manufactured in stainless and galvanised steel all range taking Atlas cable cleats are supplied with a stainless steel top bolt to eliminate eddy currents.
To protect and cushion the cables during short circuit conditions the Atlas cable cleat comes with integral LSF Zero Halogen Polymeric pads.
Ellis Patents Atlas range taking cable cleats have been tested in accordance with the European Standard of "Cable Cleats for Electrical Installations" BS EN 50368 : 2003 - Ellis Patents are the global leader in the manufacture of quality and trusted single way, trefoil, quadrafoil and range taking cable cleats.
Cembre C Tap crimps are suitable for establishing earthing systems and tapping off from low voltage overhead lines - C tap crimps accomodate copper cable conductors including run and tap offs, 2.5sqmm to 240sqmm. Tin plated and bright surface finish C Tap connectors are available.
Typical "C" Tap copper connectors applications - copper tap connections, joint connections and jointing two parallel running conductors.
Cembre copper "C" Tap connectors are manufactured from high purity copper profiles and are suitable for a variety of uses. Each copper connectors is marked as follows :
Cembre trade mark
Cembre reference number
Conductor size-run
Conductor size-tap
Number of crimps
Cembre die reference
Catalog huyndai mv lv-huyndai_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Abb Combiflex Lugs 1.5, Abb Combiflex Lugs 2.5 | AKBAR TRADING EST. JUBAILAKBAR TRADING
Contact sockets, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-A
1MRK 002 136-D
50 g
90 g
Contact pins, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-G
1MRK 002 136-H
60 g
120 g
Cembre C Tap crimps are suitable for establishing earthing systems and tapping off from low voltage overhead lines - C tap crimps accomodate copper cable conductors including run and tap offs, 2.5sqmm to 240sqmm. Tin plated and bright surface finish C Tap connectors are available.
Typical "C" Tap copper connectors applications - copper tap connections, joint connections and jointing two parallel running conductors.
Cembre copper "C" Tap connectors are manufactured from high purity copper profiles and are suitable for a variety of uses. Each copper connectors is marked as follows :
Cembre trade mark
Cembre reference number
Conductor size-run
Conductor size-tap
Number of crimps
Cembre die reference
Catalog huyndai mv lv-huyndai_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Abb Combiflex Lugs 1.5, Abb Combiflex Lugs 2.5 | AKBAR TRADING EST. JUBAILAKBAR TRADING
Contact sockets, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-A
1MRK 002 136-D
50 g
90 g
Contact pins, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-G
1MRK 002 136-H
60 g
120 g
Catalog thiết bị đóng cắt Fuji Electric - Air Circuit Breakers BT3 Series
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
Similar to Ellis Patents AR2-A31 Atlas Trefoil Cable Cleat - 24-26mm - Spec Sheet (20)
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
JMeter webinar - integration with InfluxDB and GrafanaRTTS
Watch this recorded webinar about real-time monitoring of application performance. See how to integrate Apache JMeter, the open-source leader in performance testing, with InfluxDB, the open-source time-series database, and Grafana, the open-source analytics and visualization application.
In this webinar, we will review the benefits of leveraging InfluxDB and Grafana when executing load tests and demonstrate how these tools are used to visualize performance metrics.
Length: 30 minutes
Session Overview
-------------------------------------------
During this webinar, we will cover the following topics while demonstrating the integrations of JMeter, InfluxDB and Grafana:
- What out-of-the-box solutions are available for real-time monitoring JMeter tests?
- What are the benefits of integrating InfluxDB and Grafana into the load testing stack?
- Which features are provided by Grafana?
- Demonstration of InfluxDB and Grafana using a practice web application
To view the webinar recording, go to:
https://www.rttsweb.com/jmeter-integration-webinar
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...DanBrown980551
Do you want to learn how to model and simulate an electrical network from scratch in under an hour?
Then welcome to this PowSyBl workshop, hosted by Rte, the French Transmission System Operator (TSO)!
During the webinar, you will discover the PowSyBl ecosystem as well as handle and study an electrical network through an interactive Python notebook.
PowSyBl is an open source project hosted by LF Energy, which offers a comprehensive set of features for electrical grid modelling and simulation. Among other advanced features, PowSyBl provides:
- A fully editable and extendable library for grid component modelling;
- Visualization tools to display your network;
- Grid simulation tools, such as power flows, security analyses (with or without remedial actions) and sensitivity analyses;
The framework is mostly written in Java, with a Python binding so that Python developers can access PowSyBl functionalities as well.
What you will learn during the webinar:
- For beginners: discover PowSyBl's functionalities through a quick general presentation and the notebook, without needing any expert coding skills;
- For advanced developers: master the skills to efficiently apply PowSyBl functionalities to your real-world scenarios.
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Slack (or Teams) Automation for Bonterra Impact Management (fka Social Soluti...Jeffrey Haguewood
Sidekick Solutions uses Bonterra Impact Management (fka Social Solutions Apricot) and automation solutions to integrate data for business workflows.
We believe integration and automation are essential to user experience and the promise of efficient work through technology. Automation is the critical ingredient to realizing that full vision. We develop integration products and services for Bonterra Case Management software to support the deployment of automations for a variety of use cases.
This video focuses on the notifications, alerts, and approval requests using Slack for Bonterra Impact Management. The solutions covered in this webinar can also be deployed for Microsoft Teams.
Interested in deploying notification automations for Bonterra Impact Management? Contact us at sales@sidekicksolutionsllc.com to discuss next steps.
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Tobias Schneck
As AI technology is pushing into IT I was wondering myself, as an “infrastructure container kubernetes guy”, how get this fancy AI technology get managed from an infrastructure operational view? Is it possible to apply our lovely cloud native principals as well? What benefit’s both technologies could bring to each other?
Let me take this questions and provide you a short journey through existing deployment models and use cases for AI software. On practical examples, we discuss what cloud/on-premise strategy we may need for applying it to our own infrastructure to get it to work from an enterprise perspective. I want to give an overview about infrastructure requirements and technologies, what could be beneficial or limiting your AI use cases in an enterprise environment. An interactive Demo will give you some insides, what approaches I got already working for real.
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Albert Hoitingh
In this session I delve into the encryption technology used in Microsoft 365 and Microsoft Purview. Including the concepts of Customer Key and Double Key Encryption.
Neuro-symbolic is not enough, we need neuro-*semantic*Frank van Harmelen
Neuro-symbolic (NeSy) AI is on the rise. However, simply machine learning on just any symbolic structure is not sufficient to really harvest the gains of NeSy. These will only be gained when the symbolic structures have an actual semantics. I give an operational definition of semantics as “predictable inference”.
All of this illustrated with link prediction over knowledge graphs, but the argument is general.
1. Atlas Cleat Data Sheet
Atlas cable cleats are available for Trefoil and Single cable applications where high levels of short circuit
withstand are required. As well as providing cables with significant mechanical support, the unique
patented design provides a choice of one bolt, two bolt or framing channel fixing options. Manufactured
in galvanised steel (this cleat also comes in stainless steel to offer ultimate protection against the
harshest environmental conditions) all cleats are supplied with an M12 nut and locking nut, M12 washer
and an M12 A2 stainless steel top bolt to eliminate eddy currents. The cleat is also supplied with two
M12 nuts, bolts and washers, for adjustment and two Atlas Stabilizers in Low Smoke & Fume Zero
Halogen Nylon (MDS02 Data Sheet)*. Single cable cleats are supplied with a Low Smoke & Fume Zero
Halogen Polymeric washer (MDS01 Data Sheet)*. UK Patent GB 228 4444
To protect and cushion the cables during short circuit conditions, the cleat comes with integral Low
Smoke & Fume Zero Halogen Polymeric pads (MDS01 Data Sheet)*.
For the intermediate strap type AS please contact our Sales office.
* Material Data Sheets MDS01 & MDS02 are available on request.
Single Bolt Two BoltFraming Channel
Issue 03 23/08/2011 Page 1 of 3
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.cablejoints.co.uk
www.thorneanderrick.co.uk
2. Cable
Dia. Weight
Range W H C P W H C W H C g
mm mm mm mm mm mm mm mm mm mm mm
AR2-A31-* 24-26 170 121 54 150 2xM10 144 130 54 1xM10 144 125 54 1xM10 930
AR2-A32- 26-30 170 122 54 150 2xM10 144 130 54 1xM10 144 125 54 1xM10 930
AR2-A33- 30-35 170 133 54 150 2xM10 157 141 54 1xM10 157 136 54 1xM10 970
AR2-A34- 35-40 170 134 54 150 2xM10 158 142 54 1xM10 158 137 54 1xM10 930
AR3-A35- 40-45 198 158 54 175 2xM10 185 165 54 1xM10 185 160 54 1xM10 1200
AR3-A36- 45-50 198 160 54 175 2xM10 187 167 54 1xM10 187 162 54 1xM10 1200
AR4-A37- 50-55 214 174 54 200 2xM10 204 182 54 1xM12 204 177 54 1xM12 1300
AR4-A38- 55-60 214 179 54 200 2xM10 210 187 54 1xM12 210 182 54 1xM12 1300
AR4-A39- 60-66 214 185 54 200 2xM10 217 193 54 1xM12 217 188 54 1xM12 1300
AR5-A61- 66-71 250 225 54 225 2xM10 254 225 54 1xM12 254 220 54 1xM12 1800
AR5-A62- 71-76 250 226 54 225 2xM10 255 226 54 1xM12 255 221 54 1xM12 1800
AR5-A63 76-82 250 230 54 225 2xM10 260 230 54 1xM12 260 225 54 1xM12 1800
AR8-A64- 82-92 285 250 54 225 2xM10 2100
AR8-A65- 92-102 285 250 54 225 2xM10 1900
Dimension 'C' is the cleat depth - not shown on drawing
Cable
Dia. Weight
Range W H C P W H C W H C g
mm mm mm mm mm mm mm mm mm mm mm
AR2-A11-* 38-41 170 128 54 150 2xM10 144 136 54 1xM10 144 131 54 1xM10 950
AR2-A12- 41-74 170 129 54 150 2xM10 144 136 54 1xM10 144 131 54 1xM10 930
AR2-A13- 47-55 170 140 54 150 2xM10 157 147 54 1xM10 157 142 54 1xM10 940
AR2-A14- 55-63 170 141 54 150 2xM10 158 148 54 1xM10 158 143 54 1xM10 930
AR3-A15- 63-70 198 164 54 175 2xM10 185 172 54 1xM10 185 167 54 1xM10 1200
AR3-A16- 70-79 198 166 54 175 2xM10 187 173 54 1xM10 187 168 54 1xM10 1200
AR4-A17- 79-87 214 180 54 200 2xM10 204 188 54 1xM12 204 183 54 1xM12 1300
AR4-A18- 87-95 214 186 54 200 2xM10 210 193 54 1xM12 210 188 54 1xM12 1300
AR4-A19- 95-104 214 192 54 200 2xM10 217 199 54 1xM12 217 197 54 1xM12 1300
AR5-A51- 104-112 250 231 54 225 2xM10 254 231 54 1xM12 254 226 54 1xM12 1700
AR5-A52- 112-120 250 232 54 225 2xM10 255 232 54 1xM12 255 227 54 1xM12 1700
AR5-A53 120-130 250 237 54 225 2xM10 260 237 54 1xM12 260 232 54 1xM12 1700
Dimension 'C' is the cleat depth - not shown on drawing
Issue 03 23/08/2011 Page 2 of 3
*To order please add fixing suffix: Two Bolt-TB Single Bolt-SB Framing Cleat-FC
*To order please add fixing suffix: Two Bolt-TB Single Bolt-SB Framing Cleat-FC
Fixing
Holes
Fixing
Hole
Part Number
Part Number
Fixing
holes
Fixing
Hole
Fixing
Hole
Two Bolt Single Bolt Framing Channel
Dimensions
Selection Table for Trefoil Cable Applications
N/A N/A
Selection Table for Single Cable Applications
Dimensions
Two Bolt Single Bolt Framing Channel
N/A N/A
Fixing
Hole
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.cablejoints.co.uk
www.thorneanderrick.co.uk
3. Testing Information
Issue 03 23/08/2011 Page 3 of 3
Axial Movement Test 9.5
Needle Flame Test 6.5, 10.0
Resistance to
Electro Mechanical
Force
6.3
Atlas Cleats have been tested in line with the European Standard of 'Cable Cleats for Electrical
Installations' BS EN 50368:2003. Typical results are detailed below:
Properties
BS EN 50368:2003
Classification
Clause
Units /
Classification
Atlas Trefoil Cable
Application
Test Data
Atlas Single Cable
Application
Test Data
2000 1450
Lateral Load Test 9.2 Newtons (N)
Refer to Ellis Patents
for further details.
10670
Application
Time
(seconds)
>120 >120
Temperature for
Permanent Application
6.4 o
C -40 to 60 -40 to 60
Refer to Ellis
Patents for
further
details.
Refer to Ellis Patents
for further details.
Refer to Ellis Patents
for further details.
Impact Resistance 6.2, 6.2.5, 9.3
Very heavy
Classification
(6.7kg @
300mm)
Pass Pass
Cleat Type 6.1, 6.1.3 Composite - -
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.cablejoints.co.uk
www.thorneanderrick.co.uk