This document provides information on various cleanroom products offered by LMAIRTECH, including:
1) The MDR Series modular hardwall cleanrooms that provide ISO 5 clean environments using HEPA filtration and come in various sizes.
2) The FDE Series softwall cleanrooms that use fan filter units to generate downward laminar airflow behind a vinyl curtain to achieve ISO 8 to ISO 4 cleanliness.
3) The PDE Series portable softwall cleanrooms that also use fan filter units for downward airflow behind a vinyl curtain but are mobile via lockable casters.
Vibration test assembly with Environmental Test Chamber is designed and manufactured as per specific requirement of the customers meeting various international standards.
DESIGN CONSIDERATIONS
EQUIPMENT ROOM FOR CENTRAL AIR CONDITIONING PLANT
EQUIPMENT ROOM FOR AHU AND PACKAGED UNIT
PIPE SHAFTS AND AIR DUCTS
COOLING TOWER
INDOOR DESIGN CONDITIONS AND INSTALLATION OF AHU
Vibration test assembly with Environmental Test Chamber is designed and manufactured as per specific requirement of the customers meeting various international standards.
DESIGN CONSIDERATIONS
EQUIPMENT ROOM FOR CENTRAL AIR CONDITIONING PLANT
EQUIPMENT ROOM FOR AHU AND PACKAGED UNIT
PIPE SHAFTS AND AIR DUCTS
COOLING TOWER
INDOOR DESIGN CONDITIONS AND INSTALLATION OF AHU
Esco Airstream Horizontal Laminar Flow Clean Bench blends in latest laminar flow technology and innovation to provide proven protection for your samples and processes
Full range catalogue of Airtecnics air curtains 2015.
New models: Maxwell air curtain, Recessed Dam air curtain, Recessed Compact air curtain and some heat pump air curtains.
Alfa provide wide range of Clean Room compatible Doors . These are basically meant for air ingression in the room. The door has mechanically interlocked vertical edges that add strength and rigidity, which makes them appropriate for light and heavy use.
Comprehensive BATOR Four-Fold Door System presentation. All details, drive and control system, safety features, add-ons, integration and various design options are explained with various reference pictures.
Cataloge ge 4.industrial enclosures_dienhathe.com-2_modula_plusDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
We are authorized sole Promotional, distribution & Service partners in India for M/s. E.M.B. Products AG (RODA), who are specialized In Natural/ Smoke/ Fire Ventilation Systems, Smoke Curtains used in the event of fire in any Industrial/ Commercial buildings.
We attach great importance to the high quality of all our products. All our smoke and heat extraction systems can also be used for everyday ventilation.
Esco Airstream Horizontal Laminar Flow Clean Bench blends in latest laminar flow technology and innovation to provide proven protection for your samples and processes
Full range catalogue of Airtecnics air curtains 2015.
New models: Maxwell air curtain, Recessed Dam air curtain, Recessed Compact air curtain and some heat pump air curtains.
Alfa provide wide range of Clean Room compatible Doors . These are basically meant for air ingression in the room. The door has mechanically interlocked vertical edges that add strength and rigidity, which makes them appropriate for light and heavy use.
Comprehensive BATOR Four-Fold Door System presentation. All details, drive and control system, safety features, add-ons, integration and various design options are explained with various reference pictures.
Cataloge ge 4.industrial enclosures_dienhathe.com-2_modula_plusDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
We are authorized sole Promotional, distribution & Service partners in India for M/s. E.M.B. Products AG (RODA), who are specialized In Natural/ Smoke/ Fire Ventilation Systems, Smoke Curtains used in the event of fire in any Industrial/ Commercial buildings.
We attach great importance to the high quality of all our products. All our smoke and heat extraction systems can also be used for everyday ventilation.
Diversitech’s FRED T Series Ambient Air Cleaners are designed to collect, dust smoke and other airborne particulates with a high efficiency filtration system.
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Group
Esco Enterprise Laminar Flow Straddle Units are designed for larger-scale process protection in industrial applications typically requiring multiple units connected in an assembly line configuration. They may be placed within an ISO Class 8 cleanroom to provide an ultra-clean environment directly at the process level, without the initial and operating costs associated with a full-sized ISO Class 3 or 4 cleanroom.
Nutraceutical market, scope and growth: Herbal drug technologyLokesh Patil
As consumer awareness of health and wellness rises, the nutraceutical market—which includes goods like functional meals, drinks, and dietary supplements that provide health advantages beyond basic nutrition—is growing significantly. As healthcare expenses rise, the population ages, and people want natural and preventative health solutions more and more, this industry is increasing quickly. Further driving market expansion are product formulation innovations and the use of cutting-edge technology for customized nutrition. With its worldwide reach, the nutraceutical industry is expected to keep growing and provide significant chances for research and investment in a number of categories, including vitamins, minerals, probiotics, and herbal supplements.
The increased availability of biomedical data, particularly in the public domain, offers the opportunity to better understand human health and to develop effective therapeutics for a wide range of unmet medical needs. However, data scientists remain stymied by the fact that data remain hard to find and to productively reuse because data and their metadata i) are wholly inaccessible, ii) are in non-standard or incompatible representations, iii) do not conform to community standards, and iv) have unclear or highly restricted terms and conditions that preclude legitimate reuse. These limitations require a rethink on data can be made machine and AI-ready - the key motivation behind the FAIR Guiding Principles. Concurrently, while recent efforts have explored the use of deep learning to fuse disparate data into predictive models for a wide range of biomedical applications, these models often fail even when the correct answer is already known, and fail to explain individual predictions in terms that data scientists can appreciate. These limitations suggest that new methods to produce practical artificial intelligence are still needed.
In this talk, I will discuss our work in (1) building an integrative knowledge infrastructure to prepare FAIR and "AI-ready" data and services along with (2) neurosymbolic AI methods to improve the quality of predictions and to generate plausible explanations. Attention is given to standards, platforms, and methods to wrangle knowledge into simple, but effective semantic and latent representations, and to make these available into standards-compliant and discoverable interfaces that can be used in model building, validation, and explanation. Our work, and those of others in the field, creates a baseline for building trustworthy and easy to deploy AI models in biomedicine.
Bio
Dr. Michel Dumontier is the Distinguished Professor of Data Science at Maastricht University, founder and executive director of the Institute of Data Science, and co-founder of the FAIR (Findable, Accessible, Interoperable and Reusable) data principles. His research explores socio-technological approaches for responsible discovery science, which includes collaborative multi-modal knowledge graphs, privacy-preserving distributed data mining, and AI methods for drug discovery and personalized medicine. His work is supported through the Dutch National Research Agenda, the Netherlands Organisation for Scientific Research, Horizon Europe, the European Open Science Cloud, the US National Institutes of Health, and a Marie-Curie Innovative Training Network. He is the editor-in-chief for the journal Data Science and is internationally recognized for his contributions in bioinformatics, biomedical informatics, and semantic technologies including ontologies and linked data.
Slide 1: Title Slide
Extrachromosomal Inheritance
Slide 2: Introduction to Extrachromosomal Inheritance
Definition: Extrachromosomal inheritance refers to the transmission of genetic material that is not found within the nucleus.
Key Components: Involves genes located in mitochondria, chloroplasts, and plasmids.
Slide 3: Mitochondrial Inheritance
Mitochondria: Organelles responsible for energy production.
Mitochondrial DNA (mtDNA): Circular DNA molecule found in mitochondria.
Inheritance Pattern: Maternally inherited, meaning it is passed from mothers to all their offspring.
Diseases: Examples include Leber’s hereditary optic neuropathy (LHON) and mitochondrial myopathy.
Slide 4: Chloroplast Inheritance
Chloroplasts: Organelles responsible for photosynthesis in plants.
Chloroplast DNA (cpDNA): Circular DNA molecule found in chloroplasts.
Inheritance Pattern: Often maternally inherited in most plants, but can vary in some species.
Examples: Variegation in plants, where leaf color patterns are determined by chloroplast DNA.
Slide 5: Plasmid Inheritance
Plasmids: Small, circular DNA molecules found in bacteria and some eukaryotes.
Features: Can carry antibiotic resistance genes and can be transferred between cells through processes like conjugation.
Significance: Important in biotechnology for gene cloning and genetic engineering.
Slide 6: Mechanisms of Extrachromosomal Inheritance
Non-Mendelian Patterns: Do not follow Mendel’s laws of inheritance.
Cytoplasmic Segregation: During cell division, organelles like mitochondria and chloroplasts are randomly distributed to daughter cells.
Heteroplasmy: Presence of more than one type of organellar genome within a cell, leading to variation in expression.
Slide 7: Examples of Extrachromosomal Inheritance
Four O’clock Plant (Mirabilis jalapa): Shows variegated leaves due to different cpDNA in leaf cells.
Petite Mutants in Yeast: Result from mutations in mitochondrial DNA affecting respiration.
Slide 8: Importance of Extrachromosomal Inheritance
Evolution: Provides insight into the evolution of eukaryotic cells.
Medicine: Understanding mitochondrial inheritance helps in diagnosing and treating mitochondrial diseases.
Agriculture: Chloroplast inheritance can be used in plant breeding and genetic modification.
Slide 9: Recent Research and Advances
Gene Editing: Techniques like CRISPR-Cas9 are being used to edit mitochondrial and chloroplast DNA.
Therapies: Development of mitochondrial replacement therapy (MRT) for preventing mitochondrial diseases.
Slide 10: Conclusion
Summary: Extrachromosomal inheritance involves the transmission of genetic material outside the nucleus and plays a crucial role in genetics, medicine, and biotechnology.
Future Directions: Continued research and technological advancements hold promise for new treatments and applications.
Slide 11: Questions and Discussion
Invite Audience: Open the floor for any questions or further discussion on the topic.
Professional air quality monitoring systems provide immediate, on-site data for analysis, compliance, and decision-making.
Monitor common gases, weather parameters, particulates.
A brief information about the SCOP protein database used in bioinformatics.
The Structural Classification of Proteins (SCOP) database is a comprehensive and authoritative resource for the structural and evolutionary relationships of proteins. It provides a detailed and curated classification of protein structures, grouping them into families, superfamilies, and folds based on their structural and sequence similarities.
Richard's aventures in two entangled wonderlandsRichard Gill
Since the loophole-free Bell experiments of 2020 and the Nobel prizes in physics of 2022, critics of Bell's work have retreated to the fortress of super-determinism. Now, super-determinism is a derogatory word - it just means "determinism". Palmer, Hance and Hossenfelder argue that quantum mechanics and determinism are not incompatible, using a sophisticated mathematical construction based on a subtle thinning of allowed states and measurements in quantum mechanics, such that what is left appears to make Bell's argument fail, without altering the empirical predictions of quantum mechanics. I think however that it is a smoke screen, and the slogan "lost in math" comes to my mind. I will discuss some other recent disproofs of Bell's theorem using the language of causality based on causal graphs. Causal thinking is also central to law and justice. I will mention surprising connections to my work on serial killer nurse cases, in particular the Dutch case of Lucia de Berk and the current UK case of Lucy Letby.
2. Page1
Hardwall & Softwall Cleanrooms
MDR Series – Modular Hardwall Cleanrooms – Page 2 & 3
FDE Series – Softwall Cleanroom – Fixed – Page 4 & 5
PDE Series – Softwall Cleanroom – Portable – Page 6 & 7
Cleanroom Design Guide / Drawing – Page 8 - 10
Cleanroom Services – Six Step Solution – Page 11
LoPro Series – Motorized HEPA Fan – Page 12
TCS Series – Remote Blower / HEPA Diffuser – Page 13 & 14
MDR Series
Modular Downflow
Cleanroom
FDE Series
Softwall Cleanroom Fixed
Downflow Clean Air Enclosure
PDE Series
Softwall Cleanroom Portable Downflow
Clean Air Enclosure
TCS Series
Separate HEPA Filter & Blower
Laminar Airflow T-Grid HEPA
filtration Ceiling System
Lo-Pro Series
Fan Filter Unit
Motorized HEPA
Filter Module
3. Page2
MDR SERIES - Modular Downflow Cleanroom
Applications:
Microelectronic Fabrication, Medical Device Manufacturing, QC Inspection, Sterile Filling & Packaging,
Pharmaceutical Processing, Semiconductor Manufacturing
DESCRIPTION: MDR Series - Modular Hardwall Cleanrooms -
vertical HEPA filtered airflow cleanroom providing an ISO 5 / Class
100 condition or better; available in various sizes & configurations.
The complete unit features durable modular Hardwall construction,
using prefabricated walls with wiring posts every 4’ (on center) for
efficient installation. (Other Cleanroom Classes Available.).
Specifications:
Filters - compact self-powered HEPA (High Efficiency Particulate
Air) ceiling modules. 70mm filter pack. Minimum efficiency of 99.99%
at .3 microns; 600 – 750 CFM, 55 dBA’s, (ULPA filters available)
Prefilters - 1" bonded polyfiber minimizes surface-loading. 78 %
arrestance – 56-57 ASHRAE.
Airflow - Average clean air velocity 90 fpm (+/-10 fmp). All
measured values within +/- 20% uniformity.
Construction:
- Modular Walls - available in various thicknesses – Polystyrene core (1 ¾” & 3” walls are most common).
- Wall Covering - various textures include painted Steel or Aluminum, Laminated woodboard & Vinyl covered.
- “U” Track - Base / Top cap with “H” wiring posts & pre-formed outside corners - Painted Steel or Aluminum.
- Cleanroom Doors -1 3/4" Steel or Aluminum, pre-hung with 2’ x 2’ view glass - standard doors = 3’W x 7’H;
(other doors are available including double doors, wider or higher than standard doors & also sliding doors)
- T-Grid Ceiling system - Anodized or Painted Aluminum – gasketed, Heavy duty 1 1/2" x 1 1/2"
- HEPA Fan Filter units, Cleanroom Lights & Cleanroom Ceiling Tile.
- I-beam support is provided, to allow structural & ceiling support (roof deck available)
- Cleanroom windows are available – full view or ½ view – safety glass or Polycarbonate
Electrical & Power Requirements - All electrical components are UL Approved / NEC Electrical
Code. Standard 115V, 15 Amp, 1 pH, 60 Hz. Units supplied with harness wiring or electrical panel
Motor/Blower Assembly - High efficiency Lo-Pro motors to reduce electrical load. Thermally protected &
self-lubricating High capacity metal backward curved impellers within direct drive external rotor motors to
reduce wear. Statically balanced to maintain constant airflow. Units sit within ceiling grid.
Lighting - Recessed fluorescent "cleanroom" type sealed 4 bulb Lighting - 125 ft. candle +/- 20 ft. candles.
Plastic prismatic lens cover maximizes light diffusion – Lights are drop-in style, sit within ceiling grid.
Controls - Solid state, adjustable airflow control, 70-120 fpm, 15A load capacity, switches for motor & lights.
Drawings – a complete set will be provided for all Cleanroom projects – Six Step Solution included – design
assistance, project management, installation (LM Air’s trained staff), maintenance
4. Page3
Options:
Duct collars for Fan Units
Seamless flooring
Double doors
Ionized system
Magnehelic pressure gauge
Electrical duplex receptacle
Flow through cleanroom lights
Cleanroom windows
Roof decking sealed plenum
Control panel
Sprinkler drop
TCS blower/filter system
Replacement pre-filter, 12/case
Roomside replaceable HEPA units
Single Pass or Recirculating Cleanrooms
Standard and Custom sizes / configurations available
Model # / Dimensions:
LM Air Model # W L IH OH LM Air Model # W L IH OH
MDR-88 8' 8' 8' 10' MDR-1216 12' 16' 8' 10'
MDR-812 8' 12' 8' 10' MDR-1220 12' 20' 8' 10'
MDR-816 8' 16' 8' 10' MDR-1224 12' 24' 8' 10'
MDR-820 8' 20' 8' 10' MDR-1616 16' 16' 8' 10'
MDR-824 8' 24' 8' 10' MDR-1620 16' 20' 8' 10'
MDR-1212 12' 12' 8' 10' MDR-1624 16' 24' 8' 10'
Sample Drawing:
5. Page4
FDE SERIES - Softwall Cleanroom Fixed Downflow Clean Air Enclosure
Applications:
Microelectronic Fabrication, Medical Device Manufacturing, QC Inspection, Sterile Filling & Packaging,
Pharmaceutical Processing, Semiconductor Manufacturing
DESCRIPTIONS: The Fan Filter Unit draws ambient air from
above & generates a uni-directional vertical airflow pattern that
exits beneath the vinyl curtain. Depending on the quantity of
modules used and filter efficiency an ISO 8 Class 100,000 to
ISO 4 / Class 10 clean laminar airflow can be established inside
the Softwall environment.
The FDE Series includes HEPA fan modules, cleanroom tiles,
cleanroom light fixtures that provide 125 ft. candle coverage. The
standard unit consists of tubular steel with a painted (or Stainless
steel) finish, on isolation levelers. A solid clear vinyl curtain
spaced above the floor allows a continuous downflow purge of
clean air. Various configurations & Cleanroom Classes are available to meet your specific needs.
SPECIFICATIONS:
Construction: 2” or 3” square (tubular - 11 gauge) welded frame - Painted or Stainless Steel with heavy-duty
isolation levelers; Standard Inside ceiling is 8 ft. (others are available). Aluminum, gasketed, T-Grid ceiling
system with 3/4” angle on perimeter. Pre-assembled at factory for easy installation. Gasketing ensures seal
when installed. Solid, clear 40 mil vinyl curtain perimeter with overlapping entrance (or optional Polycarbonate
walls).
Electrical & Power Requirements: All electrical components are UL Approved / NEC compliant. Standard
115V, 15A 1 Ph, 60 Hz., 15 ft. SJO power cord with 3-prong ground plug. 230V also available.
Motor/Blower Assembly: High efficiency Impellor motors reduce electrical load. Motors are thermally
protected & self-lubricating. High capacity metal backward curved impellers within direct drive external rotor
motors to reduce wear. Statically balanced to maintain constant airflow
Lighting: Recessed 2 pin fluorescent “cleanroom” type sealed 4 bulb lights - 125 ft. candle +/-20 ft. candles.
Plastic prismatic lens cover maximizes light diffusion.
Controls: Solid state airflow control, 70-120 fpm. 15A load capacity. Individual switches for motor & lights.
Drawings – a complete set will be provided for all Cleanroom projects with an easy installation guide
included OR take advantage of LM Air’s – Six Step Cleanroom Solution – design assistance, project
management, installation (LM Air’s trained staff) and maintenance.
Options:
Duct collars for Fan Units
Seamless flooring
Ionized system
Magnehelic pressure gauge
Electrical duplex receptacle
Flow through cleanroom lights
Control panel
Sprinkler drop
TCS blower/filter system
Replacement pre-filter, 12/case
Roomside replaceable HEPA units
7. Page6
PDE SERIES - Softwall Cleanroom Portable Downflow Clean Air Enclosure
Applications:
Microelectronic Fabrication, Medical Device Manufacturing, QC Inspection, Sterile Filling & Packaging,
Pharmaceutical Processing, Semiconductor Manufacturing
DESCRIPTION: The Fan Filter Unit draws ambient air from
above & generates a uni-directional vertical airflow pattern that
exits beneath the vinyl curtain. Depending on the quantity of
modules used and filter efficiency an ISO 8 Class 100,000 to
ISO 5 / Class 100 clean random airflow can be established
inside the Softwall environment.
The PDE Series includes HEPA fan modules, cleanroom tiles,
cleanroom light fixtures that provide 125 ft. candle coverage.
The standard unit consists of tubular steel with a painted (or
Stainless steel) finish, on lockable casters for mobility. A solid
clear vinyl curtain spaced above the floor allows a continuous
downflow purge of clean air. Pre-designed for product isolation
and spot coverage over process equipment. Units can be linked
together to provide multiple configurations.
SPECIFICATIONS:
Construction: 2” or 3” square (tubular - 11 gauge) welded frame - Painted or Stainless Steel with heavy-duty
lockable casters; Standard Inside ceiling is 8 ft. (others are available). Aluminum, gasketed, T-Grid ceiling
system with 3/4” angle on perimeter. Pre-assembled at factory for easy installation. Gasketing ensures seal
when installed. Solid, clear vinyl curtain perimeter with overlapping entrance (or optional Polycarbonate walls).
Electrical & Power Requirements: All electrical components are UL Approved / NEC compliant. Standard
115V, 15A 1 Ph, 60 Hz., 15 ft. SJO power cord with 3-prong ground plug. 230V also available.
Motor/Blower Assembly: High efficiency Impellor motors reduce electrical load. Motors are thermally
protected & self-lubricating. High capacity metal backward curved impellers within direct drive external rotor
motors to reduce wear. Statically balanced to maintain constant airflow.
Lighting: Recessed 2 pin fluorescent “cleanroom” type sealed 4 bulb lights - 125 ft. candle +/-20 ft. candles.
Plastic prismatic lens cover maximizes light diffusion.
Controls: Solid state airflow control, 70-120 fpm. 15A load capacity. Individual switches for motor & lights.
Drawings – a complete set will be provided for all Cleanroom projects with an easy installation guide
included OR take advantage of LM Air’s – Six Step Cleanroom Solution – design assistance, project
management, installation (LM Air’s trained staff) and maintenance.
Options:
Seamless flooring
Ionized system
Magnehelic pressure gauge
Electrical duplex receptacle
Flow through cleanroom lights
Control panel
Sprinkler drop
TCS blower/filter system
Replacement pre-filter, 12/case
Roomside replaceable HEPA units
9. Page8
Cleanroom Classifications / Design Guidelines
Description:
Cleanrooms are rated for purity according to guidelines established in Federal Standard 209D and ISO
standard 14644. Air cleanliness is specified in terms of the number of foreign particles per cubic foot (or
cubic liter) of air, relating different combinations of particle size and particle count. Lower
classifications represent cleaner rooms (E.g.: Class 100 / ISO 5 is cleaner than Class 100,000 /
ISO 8). How particles are counted depends on particle size: air with smaller particles can have higher
particle counts and still meet the class designation.
• Class 1 / ISO 3: only one particle per cubic foot – More Clean environment
• Class 10 / ISO 4: 10 particles per cubic foot
• Class 100 / ISO 5: 100 particles per cubic foot
• Class 1,000 / ISO 6: 1,000 particles per cubic foot
• Class 10,000 / ISO 7: 10,000 particles per cubic foot.
• Class 100,000 / ISO 8: 100,000 particles per cubic foot – Less Clean environment
[particles measure 0.5 micron or less in diameter]
There are (2) distinct types of Hardwall Cleanrooms:
- Single Pass Cleanroom – usually a Cleanroom within a larger conditioned room. Air is taken in
from above the Cleanroom ceiling thru HEPA fan units into the cleanroom - creating filtered (clean)
air. Positive pressure forces the air out of the cleanroom into the main room thru exhaust grills,
located just above the finished floor. Existing HVAC may be used for this option.
- Recirculating Cleanroom – usually includes a roof deck with recirculating wall(s). Air is ducted
into the roof deck (2’H plenum), located above the Cleanroom ceiling. Motorized HEPA fan units
move the air thru the HEPA filter & into the cleanroom - creating filtered (clean) air. Positive
pressure forces the air out of the cleanroom into the recirculating walls, via return air grills –
located above the floor. The air is then recirculated back to the plenum (above the Cleanroom
ceiling). Less air volume is required for this type; dedicated HVAC supply & return air is required.
Hardwall Cleanrooms are designed to provide a Clean, Controlled Environment. Cleanroom levels are
available from Class 100,000 to Class 1 (ISO Standards Class 1 thru Class 8),
The standard system consists of Panelized Cleanroom Walls, available in various thickness & textures.
The system includes “H” post – wiring posts every 4’; the structural members that support the Roof and
Ceiling system. Filtered air is provided by Self Powered Filter Units (HEPA filtered diffusers) mounted in
Ceiling. These take outside air through Prefilters, delivering filtered air through a HEPA (or ULPA) filter
into Cleanroom. Filtered air is exhausted from Cleanroom thru Exhaust Vents near Floor level. Clean
levels vary depending on quantity and configuration of Filters. All components are prefabricated and
completely Modular in design; modular rooms are considered Equipment, which may be a tax benefit.
Softwall Cleanrooms are designed to provide clean environments from Class 100,000 to Class 10
(ISO Standards Class 3 thru Class 8).
This system consists of a Tubular Steel Frame Structure that supports the Ceiling Grid and Clear Vinyl
Curtain Wall material. Filtered air is provided by Self Powered Filter Units mounted in-Ceiling that draw
outside air thru a Prefilter and deliver filtered air through a HEPA filter into Cleanroom. Filtered air is
exhausted from Cleanroom beneath the Curtain at Floor level. Clean levels will vary depending on
quantity and configuration of Filters.
All components are pre-assembled and completely modular in design. Softwall Cleanrooms can be
installed by End User or by our professional trained installers.
11. Page10
Cleanrooms - Single Pass vs Recirculating
Single Pass Cleanroom – Exhausting –
Air exhausts out into room via exhaust grills
Recirculating Cleanroom – Air is recirculated back to
plenum above ceiling via return air grills & double wall
12. Page11
FULL SERVICE CLEANROOMS - Six Step Solution
LM Air offers a full service approach to the cleanroom selection process. We offer a Six-Step
Solution, allowing customers to feel confident that they will receive their specific requirements,
within the specified time frame, at the quoted cost. Our design & manufacturing capabilities
allow us to offer a complete solution to your cleanroom requirements for new construction or
retro-fits (renovation of existing). LM Air can provide Hardwall & Softwall cleanrooms with
various wall types/textures & dimensions.
1. Initial Consultation – We will provide a comprehensive evaluation of what is needed,
the air quality level required & the system that is best suited for our customers.
2. Engineering & Design – Our highly experienced staff provide the necessary CAD
drawings needed to satisfy our customers’ requirements.
3. Manufacturing – Our manufacturing process and cost controls enable us to be very
efficient. This allows LM Air to minimize the cost to our customers.
4. Project Management & Installation – LM Air will provide project management services
& installation of the entire system. If our customer has the expertise to install the
system, then we will provide them with the guidance needed for successful completion.
5. Certification/Testing – LM Air tests all our products to assure compliance with
established government and industry standards, prior to shipping product. We will also
coordinate on-site testing/certification.
6. Maintenance – LM Air will provide any maintenance that may be required. We will also
offer annual maintenance contracts.
We value every relationship with our customers, vendors and employees and will provide the
highest levels of quality, service and reliability.
13. Page12
LO-PRO SERIES - Fan Filter Unit Motorized HEPA Filter Module
Applications:
Cleanroom Construction, Retrofit Existing Cleanrooms, Creating Clean Zones, Laser Optics,
Semiconductor Tools, Pharmaceutical Manufacturing, Optical pre-filter assembly
DESCRIPTION: All aluminum construction. Two backward curved
impeller motor / blowers for even and constant air distribution to the
filter. The Lo-Pro FDE provides a ISO 5/Class 100 laminar flow air for
new cleanroom construction, retrofitting other clean environments, and
converting non-clean areas into working clean zones. Modules mount
easily into standard T-grid ceilings. The totally self-contained unit is only
9" high; ideal for use in areas with tight ceiling restrictions. No special
wiring is needed for installation.
SPECIFICATIONS:
• Airflow 70 - 120 fpm.
• 115V, 2 Amp, 1 Ph, 60 Hz power requirements on LP-24, 1 Amp on LP-22,
• 230V available. Only 2 Amps maximum load on LP-24; 1 Amp on LP-22
Motor Blower Assembly:
• High efficiency Impellors are thermally protected & self-lubricating.
• High capacity backward curved impellers
• Fans statically balanced to maintain constant airflow.
• Low energy consumption.
By grouping & suspending Lo-Pro modules, ISO 5 /Class 100 vertical laminar flow environment
can provide spot coverage over process lines.
OPTIONS:
115V, 5 Amp or 15 Amp Air-Flow Control 230V, 5 Amp OR 15 Amp Air-Flow Control
Prefilter assembly, LP-24 10" two Duct collar, LP-24,
Prefilter assembly, LP-22 10" one Duct collar, LP-22
LFM-24 Replacement HEPA Filter for LP-24 Eight foot power cord
LFM-22 Replacement HEPA Filter for LP-22 Eye hooks (set of 4)
LFM-24U Replacement ULPA Filter for LP-24 Test ports in HEPA / ULPA (2), add
LFM-22U Replacement ULPA Filter for LP-22
MODEL LENGTH WIDTH HEIGHT AMPS @ 115V # Impellors SHIPPING WEIGHT
LP-24 24" 48" 9" 2.0 2 55 lbs.
LP-22 24" 24" 9" 1.0 1 30 lbs.
14. Page13
TCS Series - Separate HEPA Filter & Blower Laminar Airflow
T-Grid HEPA filtration Ceiling System
Applications (Ceiling component filtration system for Cleanroom designs of):
Microelectronic Fabrication, Medical Device Manufacturing, QC Inspection, Sterile Filling & Packaging,
Pharmaceutical Processing, Semiconductor Manufacturing, Medical Operating Rooms
Specification (see details)
The system's flexibility provides protection of specific priority
areas when a patterned ceiling coverage is specified. The
system will act as a HEPA filter source for Class 100 vertical
laminar flow air when the building air system is not available.
System components are:
1. TFB: Remote T-Grid blower air handler with flexible duct.
2. TCD: T-Grid HEPA filter ceiling diffuser.
The blower unit can be suspended from the main ceiling or
placed in a remote area. It can draw either ambient air from
above the ceiling, or use inducted air supply. The duct
connection size is10"diameter. Six feet of connection duct is
provided per outlet. Blowers are designed in two versions:
One outlet: drives one HEPA filter at 800 CFM
Two outlets: drives two HEPA filter at 1600 CFM
The filter diffuser mounts onto a standard 2' x 4' suspended T-Grid ceiling, and because of its shallow
length (only 24" is required for filter and duct connection), any low ceiling height can be converted into a
cleanroom. The diffuser's HEPA filter is enclosed in an aluminum housing. Space and weight saving
separators are used to create the Mini-pleat microglass fiber filter media pack that is sealed to the housing
with a urethane bonding agent. The diffuser has two ports for DOP testing and air balancing.
Specifications:
TFB Motor/Blower
TFB-1, one 10" outlet, 3/4 H.P., 800 CFM capacity
TFB-2, two 10" outlet, 3/4" H.P., 1600 CFM capacity
Six feet of connecting flex duct provided for each outlet
Eyebolts for ceiling suspension.
All electrical components are UL approved / NEC code
11 Amps, 1PH.60 Hz junction box on for hard wiring
TCD
Three inch mini-pleat media, aerosol challenged, zero-probed.
Minimum efficiency 99.99% at .3 microns, Aerosol challenger intake port
10" round duct intake port, Internal damper plate.
Prefilter: 1" bonded polyfiber media positioned at intake of motor/blower
Options:
Extra 10" flexduct (up to 25')
Airflow control
ULPA filtration, .12 microns
Replacement prefilters, 12/case
15. Page14
TCS Series - Separate HEPA Filter & Blower Laminar Airflow
T-Grid HEPA filtration Ceiling System
TFB Filter Blower Air Handler
LM Air Dimensions (inches) Motor Ship
Model L W H CFM Qty H/P Amps Lbs.
TFB-1 26 22 20 800 1 3/4 9.1 75
TFB-2 26 22 20 1600 1 3/4 9.1 75
TCD T-Grid HEPA filter Ceiling Diffuser
LM Air Dimensions (inches) Ship
Model L W H Lbs.
TCD-22 23 5/8 23 5/8 6 16
TCD-24 47 5/8 23 5/8 6 28