For control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where mechanical damage may occur. The 90°C cable is used where improved aging properties to those of 75°C PVC insulated cable are required because of higher ambient temperatures.
Datasheet Fluke 115. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
Datasheet Fluke Multimeter. Datasheet Fluke 115. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
For control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where mechanical damage may occur. The 90°C cable is used where improved aging properties to those of 75°C PVC insulated cable are required because of higher ambient temperatures.
Datasheet Fluke 115. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
Datasheet Fluke Multimeter. Datasheet Fluke 115. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
- Insulation Resistance up to 1TΩ
- Short-Circuit Current up to 1.5mA
- Wide Test Voltage from 250V to 5000V
- Diagnosis Function of PI and DAR
- Newly-designed alligator clip
- It comes with a tough hard case
- Filter function reduces noise interference for obtaining stable measurement
- Large display with Bar Graph indication and backlight
Live voltage warning
- Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
Our residential energy storge solution covers single phase 3kW, 5kW and three phase 10kW, this range is predominantly designed for PV self-consumption, back-up power, load shifting and off-grid solutions for household applications.
The Client (Mr.Nizam Hashwani) procured services of Zorays SMC Pvt Limted to get the preinstalled 42.2kW solar power system tied with the K-Electric grid. This pre-installed system required retrofit to meet compliance with AEDB & K-Electric net-metering regulations.
- Insulation Resistance up to 1TΩ
- Short-Circuit Current up to 1.5mA
- Wide Test Voltage from 250V to 5000V
- Diagnosis Function of PI and DAR
- Newly-designed alligator clip
- It comes with a tough hard case
- Filter function reduces noise interference for obtaining stable measurement
- Large display with Bar Graph indication and backlight
Live voltage warning
- Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
Our residential energy storge solution covers single phase 3kW, 5kW and three phase 10kW, this range is predominantly designed for PV self-consumption, back-up power, load shifting and off-grid solutions for household applications.
The Client (Mr.Nizam Hashwani) procured services of Zorays SMC Pvt Limted to get the preinstalled 42.2kW solar power system tied with the K-Electric grid. This pre-installed system required retrofit to meet compliance with AEDB & K-Electric net-metering regulations.
60W 24V Waterproof LED Power supplies for outdoor lighting fixtures, led strips, LED Floodlights, LED Projectors.
IP67 Waterproof level, full sealed with silicon gel. used for wet and damp conditions.
1. D ata s h e e t
SMILE5-INV
Hybrid Inverter
SMILE5-INV
610 x 236 x 615 mm
58 kg
CAN/USB
15% ~ 85% (No Condensing)
-20°C ~ 60 °C
IP65
VDE-AR-N 4105, VDE 0126-1-1, AS 4777.2, CEI 0-21, G59/3
IEC 62109-1&-2, IEC 62477-1 , IEC 62040.1.1, IEC 62116
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
Model
Dimensions (W x D x H)
Net Weight
Interace
Communication Port
Ambient Conditions
Humidity
Operating Temperature
IP Protection Class
Grid Regulation
Safety
EMC
General
Standards & Guidelines
2. Alpha ESS Co., Ltd.
D ata s h e e t
Official Website WeChat
PV Input (DC)
Max. Input PV Power
Maximum DC Voltage
Nominal DC Voltage
Start-up DC Voltage
MPP Voltage Range
MPPT Number
Maximum Input Current
Max. Short-circuit Current
Grid Output (AC)
Rated Power
Backup Output Power(Resistive load)
UPS(Resistive load)
Nominal Output Voltage
Output Voltage Range
Max. Output Current
Output Power Factor
Grid Connection
Battery Input (DC)
Nominal DC Voltage
Maximum Charging Current
Maximum Discharging Power
Efficiency
Maximum Efficiency
EURO Efficiency
Hybrid operation
6600 W
580 V
360 V
125 V
125 ~ 550 V
2
2 x 12 A
2 x 15 A
4600 W
4000W (150%Pn,10S)
Yes
230 V
180 ~ 270 V
22 A
0.8 leading to 0.8 lagging
Single-phase
48 V
100 A
5000 W
97.6%
97.0%
Headquarter:
+86 (0)513 806 068 91
info@alpha-ess.com
www.alpha-ess.com
JiuHua Road 888, Nantong High-Tech
Industrial Development Zone,
Nantong City, 226300
Germany:
+49 (0)6103 / 459 160-1
europe@alpha-ess.de
www.alpha-ess.de
Paul-Ehrlich-Straße 1a,
63225 Langen, Hessen
Australia:
+61 1300 968 933
australia@alpha-ess.com
www.alpha-ess.com.au
Suite 2, Level 1, 530 Botany Road,
Alexandria, NSW, 2015
Italy:
+39 335 5627462
info@alpha-ess.it
www.alpha-ess.it
Via Loda,17-41013 Castelfranco