- 3. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Premature bridge failure
Indicator / totalizer / junction box failure
Load cell sensor failure (lightning, moisture, fatigue)
Load cell cable or hydraulic line failure (moisture, cut, worn)
Poor maintenance
Poor site selection
Items Affecting Your Total Cost (TCO)
Primary Failure Causes that Contribute to Total Cost of Ownership
Customer Controlled
Supplier controlled
- 4. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
TRUCK
SCALE
Weighing
Technology
TELEVISION
AUDIO
VIDEO
VCR Tape
8mm film
Blue Ray Disk
Levers & Dial
33 RPM Record MP3
8-Track
Black & White
Load Cells POWERCELL
Color Big Screen HDTV
THE
DIGITAL
DIVIDE
Clear signal
High definition
Virtually no noise
Less Problems
Lower Repair costs
Longer life
Customer-focused
The future
METTLER TOLEDO POWERCELL, the only modern solution
The
Past
The
Future
is
here
Better Technology, Better Performance
- 5. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
POWERCELL PDX
POWERCELL® PDX ®
POWERCELL 760 POWERCELL PDX
The Legacy continues with POWERCELL PDX
POWERCELL MTX
POWERCELL PDX
Highest Accuracy
Unequaled Reliability
- No Junction Boxes
- Environmental Protection & Predictive Diagnostics
Leveraged 20+ years of field experience and an install
base of 1 million load cells
- 6. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Accuracy provides Return on Investment
A truck scale may still be Legal for Trade with an
error of +/- 30kg per truck
Legal weights do not equal Accurate weights
- Example:
Material cost = $0.10 / kg or $100 / t
Site processes 200 trucks per day
+/- 20 kg error per truck = $2 / truck
Annual Material Loss > $100,000
In “Tolerance” is not enough to protect profits
POWERCELL PDX Highest Accuracy
>60 Lb = 30 kg
20-60 Lb = 10 to 30 kg
Actual “as found status”
Accuracy is designed-in and field tested, and provides strong ROI
METTLER TOLEDO’s Truck Scale
Competitor’s Truck Scale
0-20 Lb = 0 to 10 kg
- 7. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Environmental Protection
Cheating
Flood, punctures & abuse
Rust and
corrosion
Lightning
Rodents
High temperature
Radio and
Electromagnetic
Cold, ice
v
Protects against the key causes of inaccuracy, downtime,
and vehicle scale failure
POWERCELL PDX Unequaled Reliability
- 8. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Model 7560 Tulare, CA (near Death
Valley)
Locations Recorded temperature
# 1 Al'Az-is-iyah, Libya 136.4° F (58.0° C)
# 2 Death Valley, USA 134.0° F (56.7° C)
Hottest Places on Earth
Locations Recorded temperature
#1 Vostok, Siberia -67° F (-55.0° C)
#2 McMurdo, Antarctic -59° F (-50.0° C)
Coldest Places on Earth
Operates in Extreme Places
Model 7560 McMurdo Station,
(only scale in Antarctic)
Reliability in Extreme Temperatures
- 9. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Unmatched Lightning Protection
Can withstand multiple lightning
strikes up to 80,000 Amperes
- An average strike is 30,000 Amperes
The only cell with REAL Proof of
System Performance
- In the lab & in the field
METTLER TOLEDO provides total
system protection for Load Cell,
Cables, and Industrial Terminals
Third party certified
POWERCELL PDX Lightning Protection
- 10. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Competitive Systems use Junction Boxes
Hard to seal against moisture
Complicated installation, troubleshooting
Expensive to maintain and failure prone
POWERCELL PDX
Has NO Junction Box
Easy to install and troubleshoot
Fast, reliable, and accurate
operation
Eliminates the #1 source of vehicle system failures -
the Junction Box
Manual wiring of
Junction Box
Removing the Junction Box
Removing the Junction Box
- 11. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Rust & Corrosion = Long Term Health Issues
Cell constructed 17-4ph stainless
Cell can constructed of 304L
Laser welded and vacuum tested
Receivers 17-4ph stainless
Stainless cables and connectors
Corrosion Protection
- 12. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Potential water entry points
Protection from Corrosion & Failure
POWERCELL PDX
Stainless steel components
Passed IP68¹ and IP69K tests
Integrated breach detection
You will always know that a cell has
been broken open - before failure!
Competitive Analog Solutions
Often made of painted/plated carbon steel
Integrated cable connection secure
Weld seams not leak tested
You will never know that a load cell has
failed!
¹ 7 days with cables attached
Protection Against Water
- 13. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
¹Creates a Faraday cage
RFI & EMI: Interference Effects Accuracy
Dual core cable creates a protective shield1
Passed EMC immunity at 10Volts per meter
- stronger than many competitive products
Resistant to telephones, CB’s and portable
radios
Good in areas with overhead power lines
Protection From Interference
- 14. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Are Rodents Eating Away Your Money?
Dual core stainless cable is standard
Not easy to chew
Abrasion resistant
Can be replaced without recalibrating the
scale
Quick release connector
Is 100% waterproof, oil resistant
Protection From Cable Damage
- 15. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Typical cheating circuit
The breach detector, inside
POWERCELL PDX warns you before
cheating occurs
This can happen with any load cell type!
K2
+EXC
-EXC
-SIG +SIG
K1
R2 R1
Thieves Potentially Stealing Your Profit?
Not with POWERCELL PDX
Protection From Tampering
- 16. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Common causes of analog truck scale failures and their costs
% of total
failures
Average
Down Time
per event
Lost
Productivity
$0.1 / kg
200 trucks/day
POWERCELL PDX
Protection
Load Cell Damage
from moisture or
lightning
25% 1-2 days $0.6 - 1.2 M
Lightning protection > 80K a
Hermetically sealed IP68 cell
Built in breach sensor
Terminal,
Summing Box, or
Junction Box
20% 0.5-1 day $0.3 – 0.6 M
No junction box to wire
Easy “click” connectors
Automated cell addressing
Cable &
connection failure 15% 0.5-1 day $0.3 – 0.6 M
Stainless sheathing on cable
Revolutionary connector
CAN Bus architecture
Poor or inadequate
maintenance 25% 2-3 days $1.2 – 1.8 M
Global Service network
Predictive diagnostic tools
Remote monitoring capability
Misapplication and
Other site specific
issues
15% 1 week Up to $3.0 M
Global sales/support network
Earth’s most experienced team
Technology leadership
POWERCELL PDX coupled with proactive service
Eliminates causes of down time and lost productivity
Eliminating Downtime
- 17. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Comprehensive Testing Program
Accuracy under
influence factors
Submersion
1 week
Vibration
and Shock
Stress Full load
@
3.4°x1M Cycles
+20 Field tests
Lightning to 82,500A
Electro
Magnetics
Pressure, Temperature
+salt spray
Proves POWERCELL PDX Performance
- 18. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
All critical errors immediately displayed to your operator
- Overloads, weighing or cell failures
- Water ingress detected by breach detector in the cell
Allows a technician to troubleshoot remotely
Problem causes are accurately pinpointed
Email alerts for fast communication of key conditions
Weighing terminals store historical data for analysis
At cell voltages Network condition
Predictive Diagnostics for Network Health
POWERCELL eliminates analog load cell weaknesses
Diagnosing the Scale Network
- 19. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Click here for a list
of items monitored
with analog load cells
What Can You Monitor With An Analog Cell?
Or Smart junction boxes?
- 20. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Items Monitored With Analog Load Cells
Complete List:
1. Weight
2.
3.
4.
5.
6.
7.
8.
9.
10.
Where’s your value?
?
- 21. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Click here for a list
of items monitored with
POWERCELL PDX
What Can Be Monitored With POWERCELL?
- 22. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Items Monitored With POWERCELL PDX
Accurate Weight
Node Address
Serial Number
Cell Counts
COM Errors
Min Supply Voltage
Supply Voltage
CAN-H Voltage
CAN-L Voltage
Major over-voltage/current
Major under-voltage
Minor over-voltage/current
Minor under-voltage
Total Transactions
Temperature Deviation
Current Temperature
Max Temperature
Min Temperature
Gas Concentration
Displacement deviation
Current Displacement
Energy Deviation
Current Energy
Zero Drift Errors
Zero Drift Value
Cell Overloads
Average Overload Weight
Symmetry Errors
Symmetry Difference
- 23. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
POWERCELL PDX – Retrofits
Upgrade your scale with POWERCELL PDX to add substantial value
POWERCELL PDX cell profile allows for easy retrofit of competitive vehicle load
cells such as: SCB, HBM, Flintec, Precia
Nearly all cell types can be replaced, even if they are not column style cells
An upgrade can be done in as little as 1 day
Upgrades can be 30-60% less expensive than a replacement scale (depending
on foundations and other factors)
You don’t have to replace your scale to gain these benefits
- 24. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
New Scale or Upgrade Existing?
An upgrade may be best if:
Your current scale is in good
mechanical shape
Your scale is less than 10-12 years old
You need to minimize downtime for
installation
A new scale may be best if:
Your current scale has areas of
significant rust or visible wear
Your scale is over 10-12 years old
You can be down for 1-4 weeks,
depending on the scale type and
foundation requirements
In either case,
If uptime is important to your business…
If scale maintenance costs are hurting your profits…
If you cannot afford to give away product for free…
The POWERCELL PDX load cell system will save you money!
- 25. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
POWERCELL PDX
Advanced Diagnostics
Unmatched Reliability
Proven Performance
Lowest Service Costs
Highest Accuracy
The load cell network with a proven return on investment
METTLER TOLEDO’s Truck Scale
- 26. All rights reserved. © 2010, Mettler-Toledo, Inc., Columbus
Feedback and further contact information
We look forward to your participation in one of our future webinars!
• For more information on vehicle weighing techonogy:
www.mt.com/vehicle
• Contact addresses for any further information
www.mt.com/contact
• For existing On Demand Webinars
www.mt.com/ondemand-webinars
• For upcoming Live Webinars
www.mt.com/live-webinars