SlideShare a Scribd company logo
1 of 8
Download to read offline
ArchitecturaLight
The modular luminaire system Lunis_R:
Flexible solutions with high functionality
in a pleasing style.

office

industry

traffic

shopping

Lunis_R
Centre Module Options
Technical Information

The synthesis of
performance
and aesthetics

public

sports
office

industry

traffic

shopping

public

sports

Centre Module Air Handling Device

General
The recessed platform of Lunis_R is capable of integrating air handling devices for air conditioning systems.
There are different versions avialable for both: air supply
and air return systems.
The luminaires come complete with all material preassembled to interface with a standard 100mm air hose.
Additionally there is a version available for air return via
a negative plenum ceiling system.
When no special valve is applied the centre is covered
with a perforated metal disk painted either in white or
metallic grey. In the case of a diffuser grill respectively a
control valve a metal ring is used in order to align the
diameter of the valve to the centre ring of the luminaire.
Options available as a standard:
1.
2.
3.

Air return via negative plenum ceiling system
Air return interfacing 100mm air hose
Air return interfacing 100mm air hose
via control valve
4. Air supply interfacing 100mm air hose
via control valve
5. Air supply interfacing 100mm air hose
via diffuser grill

Please find special information on the different versions
as a design aid for your projects on the following pages.
Product sketches, dimensions as well as air flow versus
noise and pressure diagrams are figured. The diagrams
have been taken either from the documentation of the
valve OEMs or have been measured in Sitecos´s own air
conditioning laboratory.

Product enquiries
In order to respond correctly to your enquiry we ask you to specify the complete order code of the luminaire. For that please
use the code of the luminaire´s platform and add the extension
for the desired centre module. Note also, that the light control
insert (C-Louvre, Collector lens, Glass diffuser) is handled as a
separate accessory, referring to our product brochure “Siteco
Lunis_R”.
Example:

For further information please contact your local Siteco
sales office.

Lunis_R Recessed Platform, 1x55W HFG Dimming
with air handling device for air return
interfacing 100mm air hose via control valve , white
5LR610 6-1TA1-6DE

Overview

Page 2

Siteco Lunis_R
Centre Module Options
Air handling devices
Release Juli 2001
office

industry

traffic

shopping

public

sports

Centre Module Air Handling Device
Air return via negative plenum ceiling system

RD = 70

Sketch

DA = Ø380
Ø398

Diagram: Returning Air Flow - Static Pressure -Noise Level
30

20

Order information

3,0

2,0

with perforated metal cover Extension
white RAL9010

- 6AE

metallic grey RAL9006

- 6AF

10

1,0
25

Pstat
[Pa]

Special Mounting instructions
This version differs only by the design and
the material from a standard version. The
standard mounting procedure applies.

LWA in dB(A)
Noise level
Pstat
[mm WS]

5

0,5

4

0,4

3

0,3

2

0,2

0,1

1
20

30

40

8 9 10

50
15

200

100
20

25 30

40

300

50 60 70 80

400
100

500
150

Air flow VAB

Air return via low
pressure ceiling
system
Page 3

Siteco Lunis_R
Centre Module Options
Air Handling Devices
Release Juli 2001

700 [m3/h]
·10 -3 [m3/h]
office

industry

traffic

shopping

public

sports

Centre Module Air Handling Device
Air return interfacing with 100mm air hose
100
RD = 70

Sketch

DA = Ø380
Ø398

Order information
Air hose flange 100mm with
perforated metal cover

9

Controlling the air flow
In order to control the air flow an aperture resistance pipe can be used (e.g. Siteco order
code 5LP900 7-6 (2)). Please find the curves
according to the possible predifined diameters
in the diagram.
Extension

white RAL9010

- 6BE

metallic grey RAL9006

- 6BF

7

8

5

6

3

4

1

2

0

Diagram: Returning Air Flow - Static Pressure -Noise Level
9

200
180
160

8

7

6

5

4

3 2 1 0 ohne Düse

20

140
120

Special Mounting instructions
After the ceiling cut out has been prepared
the gear box has to be connected to the
mains. The air hose should be positioned in
the centre area of the ceiling cut out while
its end protrudes approx.. 10cm beneath the
ceiling. Then the cable link is plugged onto
the luminaire´s chassis which then will be
mechanically fixed to the ceiling by operating the fast - locks. The air hose now is
attached to the 100mm flange in the centre
assembly and clamped e.g. by using a hose
clamp. After that the centre assembly has
to be fed back into the platform and be
fixed throught three screws/keyholes. Now
the circular T5 lamp has to be installed.
With Collector Lens or Glass Diffuser
The lens is kept in position directly underneath the reflector while it is locked to the
luminaire by twisting the centre module.

100
90
80
70

10

30

60
50

5

25

4

40
20
30
Pstat
[Pa]

3

20
18
16
14

2

12
10
9
8
7

1

LWA in dB(A)
Noise level

6
0,5

5
10

20
3

4

5

6

30

40

7 8 9 10

50
15

100
20

25 30 35 40

200

Air return interfacing
with 100mm air hose

Page 4

300

400 [m3/h]

50 60 70 80 90 ·10 -3 [m3/h]

Air flow VAB

With C-Louver
The centre module is bayonet - locked to the
luminaire and then the louver is snap fixed
onto it..

Pstat
[mm W

Siteco Lunis_R
Centre Module Options
Air Handling Devices
Release Juli 2001
office

industry

traffic

shopping

public

sports

Centre Module Air Handling Device
Air return interfacing with 100mm air hose via control valve
100
RD = 70

Sketch

DA = Ø380
Ø398

Controlling the air flow
In order to control the air flow the aperture of
the valve can be opened or closed by twisting
the valve´s wheel disk. The curves in the diagram relate to different vertical positions (in
mm).

Order information
Air hose flange 100mm
with control valve

Extension

white RAL9010

- 6DE

metallic grey RAL9006

Diagram: Returning Air Flow - Pressure gradient -Noise Level

- 6DF

s = -14

200
180
160

-12

-9

-5

0

5

20

140
120

Special Mounting instructions

With Collector Lens or Glass Diffuser
The lens is kept in position directly underneath the reflector while it is locked to the
luminaire by twisting the centre module.

100
90
80
70

35

p in Pa
t

50

5

30

40

4

30

3

20
18
16
14

2

12
10
9
8
7

1

LWA in dB(A)
Noise Level

6
0,5

5
10

20
3

With C-Louver
The centre module is bayonet - locked to the
luminaire and then the louver is snap fixed
onto it..

10

40

60

Total Pressure Gradient

After the ceiling cut out has been prepared
the gear box has to be connected to the
mains. The air hose should be positioned in
the centre area of the ceiling cut out while
its end protrudes approx.. 10cm beneath the
ceiling. Then the cable link is plugged onto
the luminaire´s chassis which then will be
mechanically fixed to the ceiling by operating the fast - locks. The air hose now is
attached to the 100mm flange in the centre
assembly and clamped e.g. by using a hose
clamp. After that the centre assembly has
to be fed back into the platform and be
fixed throught three screws/keyholes. Now
the circular T5 lamp has to be installed.

4

5

6

30

40

7 8 9 10

50

100

15

20

25 30 35 40

200

Page 5

400 [m3/h]

50 60 70 80 90 ·10 -3 [m3/h]

Air Flow VAB

Air return interfacing
with 100mm air hose
and control valve

300

Siteco Lunis_R
Centre Module Options
Air Handling Devices
Release Juli 2001
office

industry

traffic

shopping

public

sports

Centre Module Air Handling Device
Air supply interfacing with 100mm air hose via control valve
100
RD = 70

Sketch

DA = Ø380
Ø398

Controlling the air flow
In order to control the air flow the aperture of
the valve can be opened or closed by twisting
the valve´s wheel disk. The curves in the diagram relate to different vertical positions (in
mm).

Order information
Air hose flange 100mm
with control valve

Extension

white RAL9010

- 6CE

metallic grey RAL9006

Diagram: Supply Air Flow - Pressure gradient -Noise Level

- 6CF

s=2

200
180
160

4

6

9

12

20

140

Special Mounting instructions

120

After the ceiling cut out has been prepared
the gear box has to be connected to the
mains. The air hose should be positioned in
the centre area of the ceiling cut out while
its end protrudes approx.. 10cm beneath the
ceiling. Then the cable link is plugged onto
the luminaire´s chassis which then will be
mechanically fixed to the ceiling by operating the fast - locks. The air hose now is
attached to the 100mm flange in the centre
assembly and clamped e.g. by using a hose
clamp. After that the centre assembly has
to be fed back into the platform and be
fixed throught three screws/keyholes. Now
the circular T5 lamp has to be installed.

100
90
80
70

With Collector Lens or Glass Diffuser
The lens is kept in position directly underneath the reflector while it is locked to the
luminaire by twisting the centre module.

10

Total Pressure Gradient

p in Pa
t

60
50

5
40

40
35

30

3

30
20
18
16
14

2

12
10
9
8
7

1

LWA in dB(A)
Noise level

6
0,5

5
10

20
3

With C-Louver
The centre module is bayonet - locked to the
luminaire and then the louver is snap fixed
onto it..

4

4

5

6

30

40

7 8 9 10

50

100

15

20

25 30 35 40

200

Page 6

400 [m3/h]

50 60 70 80 90 ·10 -3 [m3/h]

Air Flow VAB

Air supply interfacing
with 100mm air hose
and control valve

300

Siteco Lunis_R
Centre Module Options
Air Handling Devices
Release Juli 2001
office

industry

traffic

shopping

public

sports

Centre Module Air Handling Device
Air supply interfacing with 100mm air hose via diffuser grid
100
RD = 70

Sketch

DA = Ø380
Ø398

Diagram: Supply Air Flow - Pressure gradient -Noise Level
20

200
180
160

Order information

120

Extension
- 6EE
- 6EF

Special Mounting instructions
After the ceiling cut out has been prepared
the gear box has to be connected to the
mains. The air hose should be positioned in
the centre area of the ceiling cut out while
its end protrudes approx.. 10cm beneath the
ceiling. Then the cable link is plugged onto
the luminaire´s chassis which then will be
mechanically fixed to the ceiling by operating the fast - locks. The air hose now is
attached to the 100mm flange in the centre
assembly and clamped e.g. by using a hose
clamp. After that the centre assembly has
to be fed back into the platform and be
fixed throught three screws/keyholes. Now
the circular T5 lamp has to be installed.

p in Pa
t

metallic grey RAL9006

10

35

60

Total Pressure Gradient

white RAL9010

40

100
90
80
70

Air hose flange 100mm
with diffuser grid

45

140

30

50

5

40

4

30

3

20
18
16
14

2

12
10
9
8
7

1

LWA in dB(A)
Noise Level

6
0,5

5
10

20
3

4

5

6

30

40

7 8 9 10

50

100

15

20

25 30 35 40

200

Air supply interfacing
with 100mm air hose
and diffuser grid
Page 7

400 [m3/h]

50 60 70 80 90 ·10 -3 [m3/h]

Air Flow VAB

With Collector Lens or Glass Diffuser
The lens is kept in position directly underneath the reflector while it is locked to the
luminaire by twisting the centre module.
With C-Louver
The centre module is bayonet - locked to the
luminaire and then the louver is snap fixed
onto it..

300

Siteco Lunis_R
Centre Module Options
Air Handling Devices
Release Juli 2001
office

industry

traffic

shopping

public

sports

Centre Module Loudspeaker

RD = 70

Sketch

DA = Ø380
Ø398

View into the opened centre module

Order Information
with perforated metal cover
white RAL9010

Extension

8 Ohm, 15 Watt

- 5CE

with transformer 100V, 3 Watt

- 5DE

with perforated metal cover
metallic grey RAL9006

Extension

8 Ohm, 15 Watt

- 5CF

with transformer 100V, 3 Watt

- 5DF

Features
The wide band speaker system integrates
with recessed and even with surface and
pendant mounted platforms. The nominal
power is 15 Watts at 8 Ohms. The frequency
response is between 70 Hz and 18 kHz (8dB). Centre modules with built - in transformer are available for application within
100v PA systems. The transformer can be
tapped at 1,5W, 3W or 6W. The module has
a perforated meatal cover. A layer of felt is
installed between speaker and cover in
order to avoid acoustic resonances as well
as to obscure the system from view.
Siteco recommends to limit the speaker
load to a maximum of 2 Watts in order to
minimise distorsion caused by acoustic
interference. For most applications 2 Watts
of nominal power are enough.

Special Mounting instructions
The module comes with an individual terminal block for the speaker. The
centre assembly with the speaker is fixed by three screws/keyholes within the
platform. As the product comes with the centre preassembled in the platform
it needs to be removed for mounting.

CentreModuleLoudspeaker
8 Ohm resp. with
transformer for 100V
systems
Page 8

Siteco Lunis_R
Centre Module Options
Loudspeaker
Release Juli 2001

More Related Content

Similar to Technical Information Lunis R

F1014R 30L-50L jacketed systems
F1014R 30L-50L jacketed systemsF1014R 30L-50L jacketed systems
F1014R 30L-50L jacketed systems
Stephen Martinelli
 
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Thorne & Derrick UK
 

Similar to Technical Information Lunis R (20)

Catalogue n° HD-E-00
Catalogue n° HD-E-00Catalogue n° HD-E-00
Catalogue n° HD-E-00
 
Innovations 2015
Innovations 2015Innovations 2015
Innovations 2015
 
Innovations 2015
Innovations  2015Innovations  2015
Innovations 2015
 
Blow-Tech Engineers, Mumbai, Direct Drive Blowers
Blow-Tech Engineers, Mumbai, Direct Drive BlowersBlow-Tech Engineers, Mumbai, Direct Drive Blowers
Blow-Tech Engineers, Mumbai, Direct Drive Blowers
 
Blow Tech Engineers, Mumbai, Ventilation Systems
Blow Tech Engineers, Mumbai, Ventilation SystemsBlow Tech Engineers, Mumbai, Ventilation Systems
Blow Tech Engineers, Mumbai, Ventilation Systems
 
Turbimax cus31 endress+hauser datasheet-turbidity sensor
Turbimax cus31 endress+hauser datasheet-turbidity sensorTurbimax cus31 endress+hauser datasheet-turbidity sensor
Turbimax cus31 endress+hauser datasheet-turbidity sensor
 
P1 d v_built
P1 d v_builtP1 d v_built
P1 d v_built
 
Technical data sheet heat exchanger BOUL
Technical data sheet heat exchanger BOULTechnical data sheet heat exchanger BOUL
Technical data sheet heat exchanger BOUL
 
Turbidity sensor-Turbimax CUS31
Turbidity sensor-Turbimax CUS31Turbidity sensor-Turbimax CUS31
Turbidity sensor-Turbimax CUS31
 
Blauboxeen
BlauboxeenBlauboxeen
Blauboxeen
 
Nidec asi silcovert h series
Nidec asi silcovert h seriesNidec asi silcovert h series
Nidec asi silcovert h series
 
Dekon Rooftop units t3 conditions
Dekon Rooftop units t3 conditions Dekon Rooftop units t3 conditions
Dekon Rooftop units t3 conditions
 
Sb ls scroll-uc_ver.3.0_en
Sb ls scroll-uc_ver.3.0_enSb ls scroll-uc_ver.3.0_en
Sb ls scroll-uc_ver.3.0_en
 
Specialising in Pneumatic Mining and Plant Equipment
Specialising in Pneumatic Mining and Plant EquipmentSpecialising in Pneumatic Mining and Plant Equipment
Specialising in Pneumatic Mining and Plant Equipment
 
Unico Small Duct Air Handler Replacement Guide Carried by Unique Indoor Comfo...
Unico Small Duct Air Handler Replacement Guide Carried by Unique Indoor Comfo...Unico Small Duct Air Handler Replacement Guide Carried by Unique Indoor Comfo...
Unico Small Duct Air Handler Replacement Guide Carried by Unique Indoor Comfo...
 
F1014R 30L-50L jacketed systems
F1014R 30L-50L jacketed systemsF1014R 30L-50L jacketed systems
F1014R 30L-50L jacketed systems
 
FanCoil-VRF-Midea-PD-CP-Technical Specifications.pdf
FanCoil-VRF-Midea-PD-CP-Technical Specifications.pdfFanCoil-VRF-Midea-PD-CP-Technical Specifications.pdf
FanCoil-VRF-Midea-PD-CP-Technical Specifications.pdf
 
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
Kamstrup ultraflow 54 ultrasonic flow meter, multical heat meter, thermal hea...
 
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
 
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous AreaStahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
Stahl C-LUX 6100 Compact Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area
 

Recently uploaded

Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...
Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...
Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...
Spesialis Kandungan Resmi BPOM
 
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Magetan
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di MagetanWA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Magetan
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Magetan
infoobataborsi24
 
Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...
Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...
Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...
ahmedjiabur940
 
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Sampang
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di SampangWA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Sampang
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Sampang
infoobataborsi24
 
How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀
How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀
How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀
Victoria Olsina
 

Recently uploaded (20)

Killer Packaging | PrintAction
Killer Packaging | PrintActionKiller Packaging | PrintAction
Killer Packaging | PrintAction
 
Best Digital Expert Corporation of India
Best Digital Expert Corporation of IndiaBest Digital Expert Corporation of India
Best Digital Expert Corporation of India
 
Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...
Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...
Klinik Jual Obat Aborsi Di Bandung wa 0851/7541/5434 Misoprostol 200mcg Pfize...
 
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Magetan
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di MagetanWA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Magetan
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Magetan
 
Digital PR & Content Marketing Lecture for Advanced Digital & Social Media St...
Digital PR & Content Marketing Lecture for Advanced Digital & Social Media St...Digital PR & Content Marketing Lecture for Advanced Digital & Social Media St...
Digital PR & Content Marketing Lecture for Advanced Digital & Social Media St...
 
Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...
Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...
Top Abortion Clinic in Muscat +918761049707!!!!!!!!!!! Get Cytotec kit availa...
 
Impacts Of Smart Watch & Wearable Technology On Daily Life
Impacts Of Smart Watch & Wearable Technology On Daily LifeImpacts Of Smart Watch & Wearable Technology On Daily Life
Impacts Of Smart Watch & Wearable Technology On Daily Life
 
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Sampang
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di SampangWA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Sampang
WA | 0821-8888-6412 | Apotik Jual Obat Aborsi Cytotec Asli Di Sampang
 
Generating Leads with Analyst Content Webinar Slides_SJN Final.pdf
Generating Leads with Analyst Content Webinar Slides_SJN Final.pdfGenerating Leads with Analyst Content Webinar Slides_SJN Final.pdf
Generating Leads with Analyst Content Webinar Slides_SJN Final.pdf
 
Valor Review – AI Transforms Any ClickBank Account Into a Money-Making Machin...
Valor Review – AI Transforms Any ClickBank Account Into a Money-Making Machin...Valor Review – AI Transforms Any ClickBank Account Into a Money-Making Machin...
Valor Review – AI Transforms Any ClickBank Account Into a Money-Making Machin...
 
Intelligent Cryptocurrency VIP Digital - Membership Area
Intelligent Cryptocurrency VIP Digital - Membership AreaIntelligent Cryptocurrency VIP Digital - Membership Area
Intelligent Cryptocurrency VIP Digital - Membership Area
 
How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀
How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀
How To Structure Your Web3 Website For Max Visibility In The Bull Market🚀
 
Fantasy Cricket Apps: A New Viewpoint for Online Cricket Betting Apps
Fantasy Cricket Apps: A New Viewpoint for Online Cricket Betting AppsFantasy Cricket Apps: A New Viewpoint for Online Cricket Betting Apps
Fantasy Cricket Apps: A New Viewpoint for Online Cricket Betting Apps
 
5 Benefits Of Using Digital Marketing.pptx
5 Benefits Of Using Digital Marketing.pptx5 Benefits Of Using Digital Marketing.pptx
5 Benefits Of Using Digital Marketing.pptx
 
The BoF Brand Magic Index Volume Two — Preview.pdf
The BoF Brand Magic Index Volume Two — Preview.pdfThe BoF Brand Magic Index Volume Two — Preview.pdf
The BoF Brand Magic Index Volume Two — Preview.pdf
 
Passive Income System 2.0 Digital: Effortless Earnings
Passive Income System 2.0 Digital: Effortless EarningsPassive Income System 2.0 Digital: Effortless Earnings
Passive Income System 2.0 Digital: Effortless Earnings
 
Taprank - Boost your Google reviews with personalized NFC cards
Taprank - Boost your Google reviews with personalized NFC cardsTaprank - Boost your Google reviews with personalized NFC cards
Taprank - Boost your Google reviews with personalized NFC cards
 
Global Trends in Market Reserch & Insights - Ray Poynter - May 2023.pdf
Global Trends in Market Reserch & Insights - Ray Poynter - May 2023.pdfGlobal Trends in Market Reserch & Insights - Ray Poynter - May 2023.pdf
Global Trends in Market Reserch & Insights - Ray Poynter - May 2023.pdf
 
The seven principles of persuasion by Dr. Robert Cialdini
The seven principles of persuasion by Dr. Robert CialdiniThe seven principles of persuasion by Dr. Robert Cialdini
The seven principles of persuasion by Dr. Robert Cialdini
 
Klaus Schweighofer, Zakaj je digitalizacija odlična priložnost za medije, Sty...
Klaus Schweighofer, Zakaj je digitalizacija odlična priložnost za medije, Sty...Klaus Schweighofer, Zakaj je digitalizacija odlična priložnost za medije, Sty...
Klaus Schweighofer, Zakaj je digitalizacija odlična priložnost za medije, Sty...
 

Technical Information Lunis R

  • 1. ArchitecturaLight The modular luminaire system Lunis_R: Flexible solutions with high functionality in a pleasing style. office industry traffic shopping Lunis_R Centre Module Options Technical Information The synthesis of performance and aesthetics public sports
  • 2. office industry traffic shopping public sports Centre Module Air Handling Device General The recessed platform of Lunis_R is capable of integrating air handling devices for air conditioning systems. There are different versions avialable for both: air supply and air return systems. The luminaires come complete with all material preassembled to interface with a standard 100mm air hose. Additionally there is a version available for air return via a negative plenum ceiling system. When no special valve is applied the centre is covered with a perforated metal disk painted either in white or metallic grey. In the case of a diffuser grill respectively a control valve a metal ring is used in order to align the diameter of the valve to the centre ring of the luminaire. Options available as a standard: 1. 2. 3. Air return via negative plenum ceiling system Air return interfacing 100mm air hose Air return interfacing 100mm air hose via control valve 4. Air supply interfacing 100mm air hose via control valve 5. Air supply interfacing 100mm air hose via diffuser grill Please find special information on the different versions as a design aid for your projects on the following pages. Product sketches, dimensions as well as air flow versus noise and pressure diagrams are figured. The diagrams have been taken either from the documentation of the valve OEMs or have been measured in Sitecos´s own air conditioning laboratory. Product enquiries In order to respond correctly to your enquiry we ask you to specify the complete order code of the luminaire. For that please use the code of the luminaire´s platform and add the extension for the desired centre module. Note also, that the light control insert (C-Louvre, Collector lens, Glass diffuser) is handled as a separate accessory, referring to our product brochure “Siteco Lunis_R”. Example: For further information please contact your local Siteco sales office. Lunis_R Recessed Platform, 1x55W HFG Dimming with air handling device for air return interfacing 100mm air hose via control valve , white 5LR610 6-1TA1-6DE Overview Page 2 Siteco Lunis_R Centre Module Options Air handling devices Release Juli 2001
  • 3. office industry traffic shopping public sports Centre Module Air Handling Device Air return via negative plenum ceiling system RD = 70 Sketch DA = Ø380 Ø398 Diagram: Returning Air Flow - Static Pressure -Noise Level 30 20 Order information 3,0 2,0 with perforated metal cover Extension white RAL9010 - 6AE metallic grey RAL9006 - 6AF 10 1,0 25 Pstat [Pa] Special Mounting instructions This version differs only by the design and the material from a standard version. The standard mounting procedure applies. LWA in dB(A) Noise level Pstat [mm WS] 5 0,5 4 0,4 3 0,3 2 0,2 0,1 1 20 30 40 8 9 10 50 15 200 100 20 25 30 40 300 50 60 70 80 400 100 500 150 Air flow VAB Air return via low pressure ceiling system Page 3 Siteco Lunis_R Centre Module Options Air Handling Devices Release Juli 2001 700 [m3/h] ·10 -3 [m3/h]
  • 4. office industry traffic shopping public sports Centre Module Air Handling Device Air return interfacing with 100mm air hose 100 RD = 70 Sketch DA = Ø380 Ø398 Order information Air hose flange 100mm with perforated metal cover 9 Controlling the air flow In order to control the air flow an aperture resistance pipe can be used (e.g. Siteco order code 5LP900 7-6 (2)). Please find the curves according to the possible predifined diameters in the diagram. Extension white RAL9010 - 6BE metallic grey RAL9006 - 6BF 7 8 5 6 3 4 1 2 0 Diagram: Returning Air Flow - Static Pressure -Noise Level 9 200 180 160 8 7 6 5 4 3 2 1 0 ohne Düse 20 140 120 Special Mounting instructions After the ceiling cut out has been prepared the gear box has to be connected to the mains. The air hose should be positioned in the centre area of the ceiling cut out while its end protrudes approx.. 10cm beneath the ceiling. Then the cable link is plugged onto the luminaire´s chassis which then will be mechanically fixed to the ceiling by operating the fast - locks. The air hose now is attached to the 100mm flange in the centre assembly and clamped e.g. by using a hose clamp. After that the centre assembly has to be fed back into the platform and be fixed throught three screws/keyholes. Now the circular T5 lamp has to be installed. With Collector Lens or Glass Diffuser The lens is kept in position directly underneath the reflector while it is locked to the luminaire by twisting the centre module. 100 90 80 70 10 30 60 50 5 25 4 40 20 30 Pstat [Pa] 3 20 18 16 14 2 12 10 9 8 7 1 LWA in dB(A) Noise level 6 0,5 5 10 20 3 4 5 6 30 40 7 8 9 10 50 15 100 20 25 30 35 40 200 Air return interfacing with 100mm air hose Page 4 300 400 [m3/h] 50 60 70 80 90 ·10 -3 [m3/h] Air flow VAB With C-Louver The centre module is bayonet - locked to the luminaire and then the louver is snap fixed onto it.. Pstat [mm W Siteco Lunis_R Centre Module Options Air Handling Devices Release Juli 2001
  • 5. office industry traffic shopping public sports Centre Module Air Handling Device Air return interfacing with 100mm air hose via control valve 100 RD = 70 Sketch DA = Ø380 Ø398 Controlling the air flow In order to control the air flow the aperture of the valve can be opened or closed by twisting the valve´s wheel disk. The curves in the diagram relate to different vertical positions (in mm). Order information Air hose flange 100mm with control valve Extension white RAL9010 - 6DE metallic grey RAL9006 Diagram: Returning Air Flow - Pressure gradient -Noise Level - 6DF s = -14 200 180 160 -12 -9 -5 0 5 20 140 120 Special Mounting instructions With Collector Lens or Glass Diffuser The lens is kept in position directly underneath the reflector while it is locked to the luminaire by twisting the centre module. 100 90 80 70 35 p in Pa t 50 5 30 40 4 30 3 20 18 16 14 2 12 10 9 8 7 1 LWA in dB(A) Noise Level 6 0,5 5 10 20 3 With C-Louver The centre module is bayonet - locked to the luminaire and then the louver is snap fixed onto it.. 10 40 60 Total Pressure Gradient After the ceiling cut out has been prepared the gear box has to be connected to the mains. The air hose should be positioned in the centre area of the ceiling cut out while its end protrudes approx.. 10cm beneath the ceiling. Then the cable link is plugged onto the luminaire´s chassis which then will be mechanically fixed to the ceiling by operating the fast - locks. The air hose now is attached to the 100mm flange in the centre assembly and clamped e.g. by using a hose clamp. After that the centre assembly has to be fed back into the platform and be fixed throught three screws/keyholes. Now the circular T5 lamp has to be installed. 4 5 6 30 40 7 8 9 10 50 100 15 20 25 30 35 40 200 Page 5 400 [m3/h] 50 60 70 80 90 ·10 -3 [m3/h] Air Flow VAB Air return interfacing with 100mm air hose and control valve 300 Siteco Lunis_R Centre Module Options Air Handling Devices Release Juli 2001
  • 6. office industry traffic shopping public sports Centre Module Air Handling Device Air supply interfacing with 100mm air hose via control valve 100 RD = 70 Sketch DA = Ø380 Ø398 Controlling the air flow In order to control the air flow the aperture of the valve can be opened or closed by twisting the valve´s wheel disk. The curves in the diagram relate to different vertical positions (in mm). Order information Air hose flange 100mm with control valve Extension white RAL9010 - 6CE metallic grey RAL9006 Diagram: Supply Air Flow - Pressure gradient -Noise Level - 6CF s=2 200 180 160 4 6 9 12 20 140 Special Mounting instructions 120 After the ceiling cut out has been prepared the gear box has to be connected to the mains. The air hose should be positioned in the centre area of the ceiling cut out while its end protrudes approx.. 10cm beneath the ceiling. Then the cable link is plugged onto the luminaire´s chassis which then will be mechanically fixed to the ceiling by operating the fast - locks. The air hose now is attached to the 100mm flange in the centre assembly and clamped e.g. by using a hose clamp. After that the centre assembly has to be fed back into the platform and be fixed throught three screws/keyholes. Now the circular T5 lamp has to be installed. 100 90 80 70 With Collector Lens or Glass Diffuser The lens is kept in position directly underneath the reflector while it is locked to the luminaire by twisting the centre module. 10 Total Pressure Gradient p in Pa t 60 50 5 40 40 35 30 3 30 20 18 16 14 2 12 10 9 8 7 1 LWA in dB(A) Noise level 6 0,5 5 10 20 3 With C-Louver The centre module is bayonet - locked to the luminaire and then the louver is snap fixed onto it.. 4 4 5 6 30 40 7 8 9 10 50 100 15 20 25 30 35 40 200 Page 6 400 [m3/h] 50 60 70 80 90 ·10 -3 [m3/h] Air Flow VAB Air supply interfacing with 100mm air hose and control valve 300 Siteco Lunis_R Centre Module Options Air Handling Devices Release Juli 2001
  • 7. office industry traffic shopping public sports Centre Module Air Handling Device Air supply interfacing with 100mm air hose via diffuser grid 100 RD = 70 Sketch DA = Ø380 Ø398 Diagram: Supply Air Flow - Pressure gradient -Noise Level 20 200 180 160 Order information 120 Extension - 6EE - 6EF Special Mounting instructions After the ceiling cut out has been prepared the gear box has to be connected to the mains. The air hose should be positioned in the centre area of the ceiling cut out while its end protrudes approx.. 10cm beneath the ceiling. Then the cable link is plugged onto the luminaire´s chassis which then will be mechanically fixed to the ceiling by operating the fast - locks. The air hose now is attached to the 100mm flange in the centre assembly and clamped e.g. by using a hose clamp. After that the centre assembly has to be fed back into the platform and be fixed throught three screws/keyholes. Now the circular T5 lamp has to be installed. p in Pa t metallic grey RAL9006 10 35 60 Total Pressure Gradient white RAL9010 40 100 90 80 70 Air hose flange 100mm with diffuser grid 45 140 30 50 5 40 4 30 3 20 18 16 14 2 12 10 9 8 7 1 LWA in dB(A) Noise Level 6 0,5 5 10 20 3 4 5 6 30 40 7 8 9 10 50 100 15 20 25 30 35 40 200 Air supply interfacing with 100mm air hose and diffuser grid Page 7 400 [m3/h] 50 60 70 80 90 ·10 -3 [m3/h] Air Flow VAB With Collector Lens or Glass Diffuser The lens is kept in position directly underneath the reflector while it is locked to the luminaire by twisting the centre module. With C-Louver The centre module is bayonet - locked to the luminaire and then the louver is snap fixed onto it.. 300 Siteco Lunis_R Centre Module Options Air Handling Devices Release Juli 2001
  • 8. office industry traffic shopping public sports Centre Module Loudspeaker RD = 70 Sketch DA = Ø380 Ø398 View into the opened centre module Order Information with perforated metal cover white RAL9010 Extension 8 Ohm, 15 Watt - 5CE with transformer 100V, 3 Watt - 5DE with perforated metal cover metallic grey RAL9006 Extension 8 Ohm, 15 Watt - 5CF with transformer 100V, 3 Watt - 5DF Features The wide band speaker system integrates with recessed and even with surface and pendant mounted platforms. The nominal power is 15 Watts at 8 Ohms. The frequency response is between 70 Hz and 18 kHz (8dB). Centre modules with built - in transformer are available for application within 100v PA systems. The transformer can be tapped at 1,5W, 3W or 6W. The module has a perforated meatal cover. A layer of felt is installed between speaker and cover in order to avoid acoustic resonances as well as to obscure the system from view. Siteco recommends to limit the speaker load to a maximum of 2 Watts in order to minimise distorsion caused by acoustic interference. For most applications 2 Watts of nominal power are enough. Special Mounting instructions The module comes with an individual terminal block for the speaker. The centre assembly with the speaker is fixed by three screws/keyholes within the platform. As the product comes with the centre preassembled in the platform it needs to be removed for mounting. CentreModuleLoudspeaker 8 Ohm resp. with transformer for 100V systems Page 8 Siteco Lunis_R Centre Module Options Loudspeaker Release Juli 2001