AIDITEC SYSTEMS DELTA RP40 - paratrăsnet cu dispozitiv de amorsare PDA,
este principalul element de instalare exterioară si de protecţie împotriva efectelor
trăsnetelor al cărui obiectiv principal constă în a capta descărcarea atmosferică.DELTA
RP40 este instalat pentru clădiri publice, întreprinderi industriale, case particulare şi
zone de recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale
trăsnetului.
1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA
2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de
evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102
FACTOR DE PROTECTIE TRIPLU.
Timp avans amorsare certificat ΔT 37µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax - 100kA
Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un
potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE
TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA -
EXTENSION OF ARCTABLE OF PROTECTION RADIUS
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 16 22 28 32
3 24 33 42 48
4 32 45 57 66
5 39 55 69 80
6 40 55 70 81
8 40 56 71 82
10 41 57 72 83
15 42 58 74 86
20 42 59 76 88
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune
reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SYSTEMS DELTA D 45 - paratrăsnet cu dispozitiv de amorsare PDA, este
principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor
al cărui obiectiv principal constă în a capta descărcarea atmosferică. . DELTA D 45 este
instalat pentru clădiri publice, întreprinderi industriale, case particulare şi zone de
recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale
trăsnetului.
1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA
2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de
evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102
FACTOR DE PROTECTIE TRIPLU.
Timp avans amorsare certificat ΔT 9 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax - 100kA Patru noi tehnologii pentru a mentine tensiunea
corecta dintre electrozi la un potential diferit asigurand o functionare perfecta. • SAT -
STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER •
FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARCTABLE OF
PROTECTION RADIUS.
Inaltime Raza de protectie in metri
H(m) Nivel1-98% Nivel2-95%
Nivel III-
90%
Nivel IV-
80%
2 10 12 15 17
3 15 18 22 26
4 21 26 31 36
5 25 30 36 42
6 25 31 37 43
8 26 32 39 45
10 27 33 41 48
15 29 36 45 52
20 29 36 48 56
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se
impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SYSTEMS DELTA RP 50 - paratrăsnet cu dispozitiv de amorsare PDA, este
principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor
al cărui obiectiv principal constă în a capta descărcarea atmosferică. .
DELTA RP 50 este instalat pentru clădiri publice, întreprinderi industriale, case
particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra
efectelor directe ale trăsnetului.
1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA
2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de
evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102
FACTOR DE PROTECTIE TRIPLU.
Timp avans amorsare certificat ΔT 45 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax - 100kA
Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un
potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE
TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA -
EXTENSION OF ARCTABLE OF PROTECTION RADIUS
Inaltime Raza de protectie in metri
H(m)
Nivel I-
98%
Nivel II-
95%
Nivel III-
90%
Nivel IV-
80%
2 20 26 32 36
3 30 39 49 54
4 40 53 66 73
5 50 65 80 89
6 50 66 81 90
8 51 66 82 91
10 51 67 83 92
15 52 68 85 95
20 52 69 86 97
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului
se impune reducerea razei de protectie cu 40% fata de valorile din acest
tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SYSTEMS DELTA RP60 - paratrăsnet cu dispozitiv de amorsare PDA, este
principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor
al cărui obiectiv principal constă în a capta descărcarea atmosferică. .
DELTA RP60 este instalat pentru clădiri publice, întreprinderi industriale, case
particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra
efectelor directe ale trăsnetului.
1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA
2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de
evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102
FACTOR DE PROTECTIE TRIPLU.
Timp avans amorsare certificat ΔT 54 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax - 100kA
Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un
potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE
TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA -
EXTENSION OF ARCTABLE OF PROTECTION RADIUS
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 24 30 36 40
3 36 45 54 60
4 49 61 73 81
5 60 75 89 100
6 60 75 90 100
8 61 76 91 101
10 61 76 92 102
15 62 78 93 105
20 62 78 95 107
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se
impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SYSTEMS DELTA RP80 - paratrăsnet cu dispozitiv de amorsare PDA, este
principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor
al cărui obiectiv principal constă în a capta descărcarea atmosferică. .
DELTA RP80 este instalat pentru clădiri publice, întreprinderi industriale, case
particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra
efectelor directe ale trăsnetului.
1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA
2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de
evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102
FACTOR DE PROTECTIE TRIPLU.
Timp avans amorsare certificat ΔT 60 µs.Factor de abatere 10 µs. Curent de
descarcare certificat Imax - 100kA
Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un
potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE
TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA -
EXTENSION OF ARCTABLE OF PROTECTION RADIUS
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 32 34 39 44
3 47 52 58 64
4 63 68 78 85
5 79 86 97 107
6 80 87 97 107
8 80 87 98 108
10 80 88 99 109
15 80 89 101 111
20 80 89 101 113
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se
impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SYSTEMS SIGMA S25 P - SIGMA S25 P este un paratrăsnet PDA din otel
inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20.
■ dublu dispozitiv de declanșare:
- Generator de anticipare a liderului ascendent.
- Circuit pentru stocarea sarcini electrice.
■ Funcționarea în orice conditii meteorologice.
■ Izolare garantata între electrozi.
■ Complet autonom și nu necesită întreținere.
Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA.
■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și
60060-1 și IEC-61083-1.
■ Eficiența 100% la descărcare.
FACTOR DE PROTECTIE DUBLU.
Timp avans amorsare certificat ΔT=6 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax=100kA.
Inaltime Raza de protectie in metri
H(m)
Nivel I-
98%
Nivel II-
95%
Nivel III-
90%
Nivel IV-
80%
2 8 10 12 14
3 10 12 14 20
4 12 14 20 25
5 14 19 24 29
6 15 20 25 30
8 16 21 27 33
10 17 23 29 35
15 19 26 33 40
20 20 28 36 44
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra
mediului se impune reducerea razei de protectie cu 40% fata de valorile
din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SIGMA S25 SIGMA S25 este un paratrăsnet PDA din otel inoxidabil AISI 316 și
testat CONFORM UNE 21186, NFC 17102 și I20.
■ dublu dispozitiv de declanșare:
- Generator de anticipare a liderului ascendent.
- Circuit pentru stocarea sarcini electrice.
■ Funcționarea în orice conditii meteorologice.
■ Izolare garantata între electrozi.
■ Complet autonom și nu necesită întreținere.
Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA.
■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și
60060-1 și IEC-61083-1.
■ Eficiența 100% la descărcare.
FACTOR DE PROTECTIE DUBLU.
Timp avans amorsare certificat ΔT=6 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax=100kA.
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 8 10 13 15
3 13 15 19 22
4 17 20 25 29
5 21 25 32 36
6 22 27 33 38
8 23 28 35 41
10 24 30 37 43
15 26 33 41 48
20 26 35 44 52
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune
reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SIGMA R40 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat
CONFORM UNE 21186, NFC 17102 și I20.
■ dublu dispozitiv de declanșare:
- Generator de anticipare a liderului ascendent.
- Circuit pentru stocarea sarcini electrice.
■ Funcționarea în orice conditii meteorologice.
■ Izolare garantata între electrozi.
■ Complet autonom și nu necesită întreținere.
Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA.
■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și
60060-1 și IEC-61083-1.
■ Eficiența 100% la descărcare.
FACTOR DE PROTECTIE DUBLU.
Timp avans amorsare certificat ΔT=33 µs.Factor de abatere 10 µs.Curent de
descarcare certificat Imax=100kA.
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 16 20 26 29
3 24 29 39 44
4 31 39 52 59
5 39 49 64 74
6 40 50 65 75
8 40 51 66 76
10 41 52 67 77
15 42 54 70 80
20 42 55 72 83
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune
reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SIGMA R55 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat
CONFORM UNE 21186, NFC 17102 și I20.
■ dublu dispozitiv de declanșare:
- Generator de anticipare a liderului ascendent.
- Circuit pentru stocarea sarcini electrice.
■ Funcționarea în orice conditii meteorologice.
■ Izolare garantata între electrozi.
■ Complet autonom și nu necesită întreținere.
Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA.
■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și
60060-1 și IEC-61083-1.
■ Eficiența 100% la descărcare.
FACTOR DE PROTECTIE DUBLU.
Timp avans amorsare certificat ΔT=41 µs. Factor de abatere 10 µs.
Curent de descarcare certificat Imax=100kA.
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 22 26 32 36
3 33 39 48 54
4 44 52 64 72
5 55 65 76 86
6 55 65 75 85
8 56 65 76 87
10 56 66 77 88
15 57 67 79 90
20 57 68 81 93
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune
reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SIGMA R65 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat
CONFORM UNE 21186, NFC 17102 și I20.
■ dublu dispozitiv de declanșare:
- Generator de anticipare a liderului ascendent.
- Circuit pentru stocarea sarcini electrice.
■ Funcționarea în orice conditii meteorologice.
■ Izolare garantata între electrozi.
■ Complet autonom și nu necesită întreținere.
Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA.
■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și
60060-1 și IEC-61083-1.
■ Eficiența 100% la descărcare.
FACTOR DE PROTECTIE DUBLU.
Timp avans amorsare certificat ΔT=49 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax=100kA.
Inaltime Raza de protectie in metri
H(m) Nivel1-98% Nivel2-95% Nivel III-90% Nivel IV-80%
2 24 30 34 38
3 36 45 51 56
4 48 60 68 75
5 65 75 85 94
6 65 75 85 95
8 66 76 86 96
10 66 76 87 97
15 66 78 89 99
20 67 78 90 101
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune
reducerea razei de protectie cu 40% fata de valorile din acest tabel.
Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro
CPT PROTECTION SRL
RO 31514524 J22 / 710 / 2013
PL: Str. Luca Arbore Nr.7
Iasi, Romania
AIDITEC SIGMA R75 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat
CONFORM UNE 21186, NFC 17102 și I20.
■ dublu dispozitiv de declanșare:
- Generator de anticipare a liderului ascendent.
- Circuit pentru stocarea sarcini electrice.
■ Funcționarea în orice conditii meteorologice.
■ Izolare garantata între electrozi.
■ Complet autonom și nu necesită întreținere.
Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA.
■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și
60060-1 și IEC-61083-1.
■ Eficiența 100% la descărcare.
FACTOR DE PROTECTIE DUBLU.
Timp avans amorsare certificat ΔT=58 µs. Factor de abatere 10 µs. Curent de
descarcare certificat Imax=100kA.
Inaltime Raza de protectie in metri
H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80%
2 30 34 38 42
3 45 51 57 63
4 60 67 76 84
5 75 84 95 104
6 75 85 95 105
8 75 85 96 106
10 75 86 97 107
15 76 87 99 109
20 76 87 100 111
In acord cu UNE 21186 ,NFC17102 si I7:
Timpul maxim de avans amorsare ΔT=60µs
In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune
reducerea razei de protectie cu 40% fata de valorile din acest tabel.

More Related Content

Featured

Content Methodology: A Best Practices Report (Webinar)
Content Methodology: A Best Practices Report (Webinar)Content Methodology: A Best Practices Report (Webinar)
Content Methodology: A Best Practices Report (Webinar)contently
 
How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024Albert Qian
 
Social Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie InsightsSocial Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie InsightsKurio // The Social Media Age(ncy)
 
Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024Search Engine Journal
 
5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summary5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summarySpeakerHub
 
ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd Clark Boyd
 
Getting into the tech field. what next
Getting into the tech field. what next Getting into the tech field. what next
Getting into the tech field. what next Tessa Mero
 
Google's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search IntentGoogle's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search IntentLily Ray
 
Time Management & Productivity - Best Practices
Time Management & Productivity -  Best PracticesTime Management & Productivity -  Best Practices
Time Management & Productivity - Best PracticesVit Horky
 
The six step guide to practical project management
The six step guide to practical project managementThe six step guide to practical project management
The six step guide to practical project managementMindGenius
 
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...RachelPearson36
 
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...Applitools
 
12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at Work12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at WorkGetSmarter
 
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...DevGAMM Conference
 
Barbie - Brand Strategy Presentation
Barbie - Brand Strategy PresentationBarbie - Brand Strategy Presentation
Barbie - Brand Strategy PresentationErica Santiago
 
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them wellGood Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them wellSaba Software
 

Featured (20)

Content Methodology: A Best Practices Report (Webinar)
Content Methodology: A Best Practices Report (Webinar)Content Methodology: A Best Practices Report (Webinar)
Content Methodology: A Best Practices Report (Webinar)
 
How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024
 
Social Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie InsightsSocial Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie Insights
 
Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024
 
5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summary5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summary
 
ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd
 
Getting into the tech field. what next
Getting into the tech field. what next Getting into the tech field. what next
Getting into the tech field. what next
 
Google's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search IntentGoogle's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search Intent
 
How to have difficult conversations
How to have difficult conversations How to have difficult conversations
How to have difficult conversations
 
Introduction to Data Science
Introduction to Data ScienceIntroduction to Data Science
Introduction to Data Science
 
Time Management & Productivity - Best Practices
Time Management & Productivity -  Best PracticesTime Management & Productivity -  Best Practices
Time Management & Productivity - Best Practices
 
The six step guide to practical project management
The six step guide to practical project managementThe six step guide to practical project management
The six step guide to practical project management
 
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
 
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
 
12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at Work12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at Work
 
ChatGPT webinar slides
ChatGPT webinar slidesChatGPT webinar slides
ChatGPT webinar slides
 
More than Just Lines on a Map: Best Practices for U.S Bike Routes
More than Just Lines on a Map: Best Practices for U.S Bike RoutesMore than Just Lines on a Map: Best Practices for U.S Bike Routes
More than Just Lines on a Map: Best Practices for U.S Bike Routes
 
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
 
Barbie - Brand Strategy Presentation
Barbie - Brand Strategy PresentationBarbie - Brand Strategy Presentation
Barbie - Brand Strategy Presentation
 
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them wellGood Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
 

Paratrasnet cu amorsare aiditec systems catalog

  • 1. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SYSTEMS DELTA RP40 - paratrăsnet cu dispozitiv de amorsare PDA, este principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor al cărui obiectiv principal constă în a capta descărcarea atmosferică.DELTA RP40 este instalat pentru clădiri publice, întreprinderi industriale, case particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale trăsnetului. 1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA 2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102 FACTOR DE PROTECTIE TRIPLU. Timp avans amorsare certificat ΔT 37µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax - 100kA Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARCTABLE OF PROTECTION RADIUS Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 16 22 28 32 3 24 33 42 48 4 32 45 57 66 5 39 55 69 80 6 40 55 70 81 8 40 56 71 82 10 41 57 72 83 15 42 58 74 86 20 42 59 76 88 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 2. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SYSTEMS DELTA D 45 - paratrăsnet cu dispozitiv de amorsare PDA, este principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor al cărui obiectiv principal constă în a capta descărcarea atmosferică. . DELTA D 45 este instalat pentru clădiri publice, întreprinderi industriale, case particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale trăsnetului. 1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA 2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102 FACTOR DE PROTECTIE TRIPLU. Timp avans amorsare certificat ΔT 9 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax - 100kA Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARCTABLE OF PROTECTION RADIUS. Inaltime Raza de protectie in metri H(m) Nivel1-98% Nivel2-95% Nivel III- 90% Nivel IV- 80% 2 10 12 15 17 3 15 18 22 26 4 21 26 31 36 5 25 30 36 42 6 25 31 37 43 8 26 32 39 45 10 27 33 41 48 15 29 36 45 52 20 29 36 48 56 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 3. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SYSTEMS DELTA RP 50 - paratrăsnet cu dispozitiv de amorsare PDA, este principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor al cărui obiectiv principal constă în a capta descărcarea atmosferică. . DELTA RP 50 este instalat pentru clădiri publice, întreprinderi industriale, case particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale trăsnetului. 1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA 2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102 FACTOR DE PROTECTIE TRIPLU. Timp avans amorsare certificat ΔT 45 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax - 100kA Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARCTABLE OF PROTECTION RADIUS Inaltime Raza de protectie in metri H(m) Nivel I- 98% Nivel II- 95% Nivel III- 90% Nivel IV- 80% 2 20 26 32 36 3 30 39 49 54 4 40 53 66 73 5 50 65 80 89 6 50 66 81 90 8 51 66 82 91 10 51 67 83 92 15 52 68 85 95 20 52 69 86 97 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 4. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SYSTEMS DELTA RP60 - paratrăsnet cu dispozitiv de amorsare PDA, este principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor al cărui obiectiv principal constă în a capta descărcarea atmosferică. . DELTA RP60 este instalat pentru clădiri publice, întreprinderi industriale, case particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale trăsnetului. 1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA 2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102 FACTOR DE PROTECTIE TRIPLU. Timp avans amorsare certificat ΔT 54 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax - 100kA Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARCTABLE OF PROTECTION RADIUS Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 24 30 36 40 3 36 45 54 60 4 49 61 73 81 5 60 75 89 100 6 60 75 90 100 8 61 76 91 101 10 61 76 92 102 15 62 78 93 105 20 62 78 95 107 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 5. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SYSTEMS DELTA RP80 - paratrăsnet cu dispozitiv de amorsare PDA, este principalul element de instalare exterioară si de protecţie împotriva efectelor trăsnetelor al cărui obiectiv principal constă în a capta descărcarea atmosferică. . DELTA RP80 este instalat pentru clădiri publice, întreprinderi industriale, case particulare şi zone de recreere, pentru protecţia persoanelor şi animalelor contra efectelor directe ale trăsnetului. 1º Rezistanta mare la curent*: 10/350μs, amplitudine de100kA 2 Timp de avansº*:Aplicareaa 100 de impulsuri, procedura prevăzută în anexa "test de evaluare a unui paratrasnet ESE", pentru UNE 21186 ,NFC17102 FACTOR DE PROTECTIE TRIPLU. Timp avans amorsare certificat ΔT 60 µs.Factor de abatere 10 µs. Curent de descarcare certificat Imax - 100kA Patru noi tehnologii pentru a mentine tensiunea corecta dintre electrozi la un potential diferit asigurand o functionare perfecta. • SAT - STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER • FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARCTABLE OF PROTECTION RADIUS Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 32 34 39 44 3 47 52 58 64 4 63 68 78 85 5 79 86 97 107 6 80 87 97 107 8 80 87 98 108 10 80 88 99 109 15 80 89 101 111 20 80 89 101 113 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 6. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SYSTEMS SIGMA S25 P - SIGMA S25 P este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20. ■ dublu dispozitiv de declanșare: - Generator de anticipare a liderului ascendent. - Circuit pentru stocarea sarcini electrice. ■ Funcționarea în orice conditii meteorologice. ■ Izolare garantata între electrozi. ■ Complet autonom și nu necesită întreținere. Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA. ■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și 60060-1 și IEC-61083-1. ■ Eficiența 100% la descărcare. FACTOR DE PROTECTIE DUBLU. Timp avans amorsare certificat ΔT=6 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax=100kA. Inaltime Raza de protectie in metri H(m) Nivel I- 98% Nivel II- 95% Nivel III- 90% Nivel IV- 80% 2 8 10 12 14 3 10 12 14 20 4 12 14 20 25 5 14 19 24 29 6 15 20 25 30 8 16 21 27 33 10 17 23 29 35 15 19 26 33 40 20 20 28 36 44 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 7. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SIGMA S25 SIGMA S25 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20. ■ dublu dispozitiv de declanșare: - Generator de anticipare a liderului ascendent. - Circuit pentru stocarea sarcini electrice. ■ Funcționarea în orice conditii meteorologice. ■ Izolare garantata între electrozi. ■ Complet autonom și nu necesită întreținere. Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA. ■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și 60060-1 și IEC-61083-1. ■ Eficiența 100% la descărcare. FACTOR DE PROTECTIE DUBLU. Timp avans amorsare certificat ΔT=6 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax=100kA. Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 8 10 13 15 3 13 15 19 22 4 17 20 25 29 5 21 25 32 36 6 22 27 33 38 8 23 28 35 41 10 24 30 37 43 15 26 33 41 48 20 26 35 44 52 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 8. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SIGMA R40 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20. ■ dublu dispozitiv de declanșare: - Generator de anticipare a liderului ascendent. - Circuit pentru stocarea sarcini electrice. ■ Funcționarea în orice conditii meteorologice. ■ Izolare garantata între electrozi. ■ Complet autonom și nu necesită întreținere. Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA. ■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și 60060-1 și IEC-61083-1. ■ Eficiența 100% la descărcare. FACTOR DE PROTECTIE DUBLU. Timp avans amorsare certificat ΔT=33 µs.Factor de abatere 10 µs.Curent de descarcare certificat Imax=100kA. Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 16 20 26 29 3 24 29 39 44 4 31 39 52 59 5 39 49 64 74 6 40 50 65 75 8 40 51 66 76 10 41 52 67 77 15 42 54 70 80 20 42 55 72 83 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 9. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SIGMA R55 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20. ■ dublu dispozitiv de declanșare: - Generator de anticipare a liderului ascendent. - Circuit pentru stocarea sarcini electrice. ■ Funcționarea în orice conditii meteorologice. ■ Izolare garantata între electrozi. ■ Complet autonom și nu necesită întreținere. Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA. ■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și 60060-1 și IEC-61083-1. ■ Eficiența 100% la descărcare. FACTOR DE PROTECTIE DUBLU. Timp avans amorsare certificat ΔT=41 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax=100kA. Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 22 26 32 36 3 33 39 48 54 4 44 52 64 72 5 55 65 76 86 6 55 65 75 85 8 56 65 76 87 10 56 66 77 88 15 57 67 79 90 20 57 68 81 93 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 10. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SIGMA R65 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20. ■ dublu dispozitiv de declanșare: - Generator de anticipare a liderului ascendent. - Circuit pentru stocarea sarcini electrice. ■ Funcționarea în orice conditii meteorologice. ■ Izolare garantata între electrozi. ■ Complet autonom și nu necesită întreținere. Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA. ■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și 60060-1 și IEC-61083-1. ■ Eficiența 100% la descărcare. FACTOR DE PROTECTIE DUBLU. Timp avans amorsare certificat ΔT=49 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax=100kA. Inaltime Raza de protectie in metri H(m) Nivel1-98% Nivel2-95% Nivel III-90% Nivel IV-80% 2 24 30 34 38 3 36 45 51 56 4 48 60 68 75 5 65 75 85 94 6 65 75 85 95 8 66 76 86 96 10 66 76 87 97 15 66 78 89 99 20 67 78 90 101 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.
  • 11. Tel: 0767 21 61 61 E-mail: office@paratrasnet-cpt.ro Web: www.paratrasnet-cpt.ro CPT PROTECTION SRL RO 31514524 J22 / 710 / 2013 PL: Str. Luca Arbore Nr.7 Iasi, Romania AIDITEC SIGMA R75 este un paratrăsnet PDA din otel inoxidabil AISI 316 și testat CONFORM UNE 21186, NFC 17102 și I20. ■ dublu dispozitiv de declanșare: - Generator de anticipare a liderului ascendent. - Circuit pentru stocarea sarcini electrice. ■ Funcționarea în orice conditii meteorologice. ■ Izolare garantata între electrozi. ■ Complet autonom și nu necesită întreținere. Testele au fost efectuate de către Institutul pentru tehnologiile energetice (ITE) SPANIA. ■ Test de timp in avans. În conformitate cu anexa "C" a UNE 21186, NFC NP 1702 și 60060-1 și IEC-61083-1. ■ Eficiența 100% la descărcare. FACTOR DE PROTECTIE DUBLU. Timp avans amorsare certificat ΔT=58 µs. Factor de abatere 10 µs. Curent de descarcare certificat Imax=100kA. Inaltime Raza de protectie in metri H(m) Nivel I-98% Nivel II-95% Nivel III-90% Nivel IV-80% 2 30 34 38 42 3 45 51 57 63 4 60 67 76 84 5 75 84 95 104 6 75 85 95 105 8 75 85 96 106 10 75 86 97 107 15 76 87 99 109 20 76 87 100 111 In acord cu UNE 21186 ,NFC17102 si I7: Timpul maxim de avans amorsare ΔT=60µs In cadrul instalatiilor care pot prezinta efecte daunatoare asupra mediului se impune reducerea razei de protectie cu 40% fata de valorile din acest tabel.