Look to Maysteel for the finest in medium-voltage, metal-enclosed banks having
capacitive reactive power ratings up to 30 MVAR in a single enclosure. These
robust units are designed to improve power factor in a variety of industrial, com-
mercial and utility applications.

Both fixed designs and automatically switched designs (up to 20 steps) are
available, in system voltages from 2.4 kV through 34.5 kV RMS. Metal-enclosed
versions are designed for substation use; pad-mount versions are for use in
publicly accessible areas. Other major features include:

       •   Free-standing, heavy-gauge, compartmentalized Maysteel enclosures
       •   Both front and rear doors for easy accessibility
       •   Integral control and protection systems
       •   Short circuit ratings to 61 kA RMS symmetrical
       •   Fused main disconnect switch or interlock with grounding switch
       •   Available fully assembled, or shipped in sections for field assembly
       •   All equipment meets or exceeds ANSI, IEEE, NEC and NESC standards




 ISO 9001
 CERTIFIED
                                                              Electric Power Products
Viewing windows
                                        available as option.                                                    Enclosure
Easy access
                                                                                                                Features
control cabinet.
                                                                                  Doors equipped with three-point latching
                                                                                  mechanism, padlockable handles.




                                                                                                                    Mesh-backed
                                                                                                                    ventilation louvers
                                                                                                                    allow filters to be
                                                                                                                    changed without
                                                                                                                    opening enclosure.




                                                                               Key interlock system ensures
                                                                               safety through proper sequence
Robust, formed-channel base simplifies                                         of operation.
installation, allowing single-piece shipments
in lengths up to 50 feet; constructed of
7 gauge hot-rolled steel or 304L stainless
steel (optional).
                                                   • Standard construction: 12 gauge hot rolled steel construction,
                                                      pickled and oiled ASTM A569, Type 1010.

                                                   • Optional constructions:
                                                      11 gauge hot rolled steel       Galvanneal A60 grade
                                                      Aluminum                        304L or 316 stainless steel

                                                   • Polyester powder coat finish. Available colors:
                                                      Gray – ANSI 61, Munsell 8.3BG 6.10/0.54
                                                      Gray – ANSI 70, Munsell 5BG 7.0/0.4
                                                      Green – Munsell 7GY 3.29/1.5

                                                   • Degrees of protection: NEMA 3R standard; NEMA 1, 4X, 12 and 13 optional.
                                                   • Fan system in NEMA 1 and 3R enclosures; air conditioning in
                                                      NEMA 4X, 12 and 13.

                                                   • Stainless steel hinges, hinge pins, fasteners and associated hardware.
                                                   • Doors on front and rear of enclosure for easy access.
Seam cap, drip edge and
pitched roof provide maximum                       • Control compartment equipped with thermostatically controlled heater
rain protection.                                      and GFI duplex outlet.

                                                   • Interior lighting in control compartment, main disconnect compartment
                                                      and all compartments containing medium-voltage power components.
Electrical
Features


       Controllers can switch stages based
       on current, power factor, temperature,        Main fuses provide
       time or voltage.                              over-current protection
                                                     to main bus, back-up
                                                     protection to power
                                                     components.




                                                AUtO / OFF / ON                Arresters protect from transient
                                                switches, and Stage            over-current caused by lightning or
                                                OFF and Stage ON               switching. Heavy-duty distribution
                                                press-to-test pilot lights.    class arresters standard; intermediate
                                                                               station class optional.




                                                  Fused control power
                                                  transformer is located
                                                  ahead of main disconnect,
                                                  allowing control and
                                                  protection circuits to
                                                  be tested before main
                                                  power is applied.




                                                                               Main disconnect switch, located in
                                                                               isolated compartment, allows arresters,
                                                                               main fuses and other components to be
                                                                               serviced without the need to disconnect
                                                                               power to the feed bus.




Metal-Enclosed,
Power Capacitor Banks
Air-insulated, load-break main disconnect switch equipped with mechanically
interlocked ground switch, which grounds the load-side for safety during maintenance.
External operation provides the visible break required by National Electrical Code.




                                                                                        Copper power bus rated at 1,000
                                                                                        amperes RMS per inch2 throughout.




                                          Ground switch




                                                       transient Inrush Reactors
                                                       Multi-stage power capacitor banks are equipped with air-core, dry-type, single-
                                                       phase transient inrush reactors that reduce the frequency and magnitude of the
                                                       inrush current that result from back-to-back switching of stages.
Capacitor banks are configured ungrounded
wye standard, delta or grounded wye optional.
Externally fused units are standard, internally
fused available upon request.

All capacitors use environmentally friendly,
biodegradable dielectric fluid with no
PCB content.

Internal discharge resistors reduce residual
voltage to less than 50 volts within five minutes
of de-energizing.

low-loss, double-bushing capacitor units
meet or exceed IEC 871 and IEEE Standard 18.

Rear-entry doors provide easy access to
capacitor units; simple capacitor mounting
system facilitates removal and change-out.




                                                    Each capacitor unit is protected against case rupture
                                                    by a current-limited fuse with a 63kA RMS symmetrical
                                                    interrupting capacity.




Stages are controlled by single-phase vacuum
switches (pictured), single-phase oil switches,
three-phase vacuum interrupters or three-phase
vacuum contactors.




                                                                 Automatic detection system provides both local and
                                                                 remote indication that one or more capacitor unit fuses
                                                                 in a stage has operated.




                                                                                             Electric Power Products
Typical Capacitor Bank Schematic
                                                                                                                 Power Capacitor Bank
                                                                             Power Capacitor                        Ground Switch
                                                                               Unit Fuses    Power Capacitor
                                                                                                 Units
                                                             Transient Inrush                                                  S2
                               Main Disconnect              Reactors, Optional
                                   Switch
                                                                                                          C1
                                                                                           F1
                                                 S1
                                                                L1
                           A                                                                              C2
                                                                                           F2
                                                              MOV1



                                                                                                          C3
                                                                                           F3
             Power Input




                                                                L2
                           B                                                                              C4
                                                                                           F4
                                                              MOV2



                                                                                                          C5
                                                                                           F5

                                                                L3
                           C                                                                              C6
                                                                                           F6
                                                              MOV3



                                                         Arresters
                                                                                                                  CT1
                                           CPT1


                               Control Power                                                          Neutral Current Transformer,
                                Transformer                                                           to Neutral Unbalance Relay



Representative Applications
                                                                                  • Wind farms
                                                                                  • Oil refineries
                                                                                  • Utility substations




                                                                www.maysteel.com
                                      MAyStEEl Electric Power Products W142 N9041 Fountain Blvd. , Menomonee Falls, WI 53051
                                      PO Box 1240, Menomonee Falls, WI 53052-1240 • Phone 877/219-9728 • Fax 262/251-0069
© 2007 Maysteel, LLC                                                                                                                    SS125 - 2/07

More Related Content

What's hot

Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...
Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...
Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...Alarm Grid
 
Powerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control SystemsPowerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control Systemsalexandriaweber
 
Zone Control Basics
Zone Control BasicsZone Control Basics
Zone Control BasicsAshley
 
radiant heater datasheets
radiant heater datasheetsradiant heater datasheets
radiant heater datasheetsdanc6ct7be
 
Honeywell 5883h-install-guide
Honeywell 5883h-install-guideHoneywell 5883h-install-guide
Honeywell 5883h-install-guideAlarm Grid
 
Natgraph Air Force Dryers & Options
Natgraph Air Force Dryers & OptionsNatgraph Air Force Dryers & Options
Natgraph Air Force Dryers & OptionsNatgraph
 
Pulsar iii se-suction_blast_cabinet
Pulsar iii se-suction_blast_cabinetPulsar iii se-suction_blast_cabinet
Pulsar iii se-suction_blast_cabinetJane Smith
 
Catalog busbar ls 05. busduct catalogue e series ver 6.5
Catalog busbar ls 05. busduct catalogue e series ver 6.5Catalog busbar ls 05. busduct catalogue e series ver 6.5
Catalog busbar ls 05. busduct catalogue e series ver 6.5Dien Ha The
 
Ao cyclone xi brochor
Ao cyclone xi brochorAo cyclone xi brochor
Ao cyclone xi brochorsonny264
 

What's hot (16)

Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...
Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...
Honeywell 5881enl-honeywell-5881enm-honeywell-5881enh-honeywell-5881enhc-inst...
 
Powerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control SystemsPowerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control Systems
 
Sr
SrSr
Sr
 
Zone Control Basics
Zone Control BasicsZone Control Basics
Zone Control Basics
 
9941201a
9941201a9941201a
9941201a
 
radiant heater datasheets
radiant heater datasheetsradiant heater datasheets
radiant heater datasheets
 
Honeywell 5883h-install-guide
Honeywell 5883h-install-guideHoneywell 5883h-install-guide
Honeywell 5883h-install-guide
 
Audible visible notification
Audible visible notificationAudible visible notification
Audible visible notification
 
Natgraph Air Force Dryers & Options
Natgraph Air Force Dryers & OptionsNatgraph Air Force Dryers & Options
Natgraph Air Force Dryers & Options
 
Pulsar iii se-suction_blast_cabinet
Pulsar iii se-suction_blast_cabinetPulsar iii se-suction_blast_cabinet
Pulsar iii se-suction_blast_cabinet
 
Catalog busbar ls 05. busduct catalogue e series ver 6.5
Catalog busbar ls 05. busduct catalogue e series ver 6.5Catalog busbar ls 05. busduct catalogue e series ver 6.5
Catalog busbar ls 05. busduct catalogue e series ver 6.5
 
Neutrik
Neutrik Neutrik
Neutrik
 
Fracaro ponuda
Fracaro ponudaFracaro ponuda
Fracaro ponuda
 
Ao cyclone xi brochor
Ao cyclone xi brochorAo cyclone xi brochor
Ao cyclone xi brochor
 
308741
308741308741
308741
 
Instructions iq2020-with-new-relay-board
Instructions iq2020-with-new-relay-boardInstructions iq2020-with-new-relay-board
Instructions iq2020-with-new-relay-board
 

Similar to Smartbank Powercap Mv Me Ss125

01. sentron 3 wl brochure
01. sentron 3 wl brochure01. sentron 3 wl brochure
01. sentron 3 wl brochureangelochintu
 
Low voltage switchgear ansi (distib. prim. bt)
Low voltage switchgear ansi (distib. prim. bt)Low voltage switchgear ansi (distib. prim. bt)
Low voltage switchgear ansi (distib. prim. bt)Moi Reyes
 
Siemens Sivacon S8 Info
Siemens Sivacon S8 InfoSiemens Sivacon S8 Info
Siemens Sivacon S8 Infonor52097
 
01. hrc din fuses 3 na
01. hrc din fuses  3 na01. hrc din fuses  3 na
01. hrc din fuses 3 naangelochintu
 
01. hrc din fuses 3 na
01. hrc din fuses  3 na01. hrc din fuses  3 na
01. hrc din fuses 3 naangeloneha
 
A Comparison of Contemporary Electrical Distribution Equipment Standards
A Comparison of Contemporary Electrical Distribution Equipment StandardsA Comparison of Contemporary Electrical Distribution Equipment Standards
A Comparison of Contemporary Electrical Distribution Equipment Standardsmichaeljmack
 
Switchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptxSwitchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptxLoitaFredy
 
02. sentron 3 wt brochure
02. sentron 3 wt brochure02. sentron 3 wt brochure
02. sentron 3 wt brochureangeloneha
 
Switchgears and protection devices
Switchgears and protection devicesSwitchgears and protection devices
Switchgears and protection devicesManojkarader
 
Natgraph Self Contained Exposure Units
Natgraph Self Contained Exposure UnitsNatgraph Self Contained Exposure Units
Natgraph Self Contained Exposure UnitsNatgraph
 
5 Reasons You Need the Latest Generation of iPDU
5 Reasons You Need the Latest Generation of iPDU5 Reasons You Need the Latest Generation of iPDU
5 Reasons You Need the Latest Generation of iPDURaritan
 
1.9 protection of power system
1.9 protection of power system1.9 protection of power system
1.9 protection of power systemW3Edify
 
Distribution boards and Protection devices ppt
Distribution boards and Protection devices  pptDistribution boards and Protection devices  ppt
Distribution boards and Protection devices pptZuhairQadri
 
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdfEEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdfAnbarasuL1
 
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdfEEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdfKarthikkumar Shanmugam
 

Similar to Smartbank Powercap Mv Me Ss125 (20)

01. sentron 3 wl brochure
01. sentron 3 wl brochure01. sentron 3 wl brochure
01. sentron 3 wl brochure
 
Acb1
Acb1Acb1
Acb1
 
Low voltage switchgear ansi (distib. prim. bt)
Low voltage switchgear ansi (distib. prim. bt)Low voltage switchgear ansi (distib. prim. bt)
Low voltage switchgear ansi (distib. prim. bt)
 
Siemens Sivacon S8 Info
Siemens Sivacon S8 InfoSiemens Sivacon S8 Info
Siemens Sivacon S8 Info
 
01. hrc din fuses 3 na
01. hrc din fuses  3 na01. hrc din fuses  3 na
01. hrc din fuses 3 na
 
01. hrc din fuses 3 na
01. hrc din fuses  3 na01. hrc din fuses  3 na
01. hrc din fuses 3 na
 
A Comparison of Contemporary Electrical Distribution Equipment Standards
A Comparison of Contemporary Electrical Distribution Equipment StandardsA Comparison of Contemporary Electrical Distribution Equipment Standards
A Comparison of Contemporary Electrical Distribution Equipment Standards
 
Switchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptxSwitchgear and protection engineering Lecture 02.pptx
Switchgear and protection engineering Lecture 02.pptx
 
02. sentron 3 wt brochure
02. sentron 3 wt brochure02. sentron 3 wt brochure
02. sentron 3 wt brochure
 
Acb2
Acb2Acb2
Acb2
 
Switchgears and protection devices
Switchgears and protection devicesSwitchgears and protection devices
Switchgears and protection devices
 
Natgraph Self Contained Exposure Units
Natgraph Self Contained Exposure UnitsNatgraph Self Contained Exposure Units
Natgraph Self Contained Exposure Units
 
5 Reasons You Need the Latest Generation of iPDU
5 Reasons You Need the Latest Generation of iPDU5 Reasons You Need the Latest Generation of iPDU
5 Reasons You Need the Latest Generation of iPDU
 
1.9 protection of power system
1.9 protection of power system1.9 protection of power system
1.9 protection of power system
 
Distribution boards and Protection devices ppt
Distribution boards and Protection devices  pptDistribution boards and Protection devices  ppt
Distribution boards and Protection devices ppt
 
LayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: eRPP Remote Power PanelLayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: eRPP Remote Power Panel
 
Industrial Linear Electric Actuators for Valves
Industrial Linear Electric Actuators for ValvesIndustrial Linear Electric Actuators for Valves
Industrial Linear Electric Actuators for Valves
 
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdfEEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
 
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdfEEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
EEE- BEE601 - TRANSMISSION AND DISTRIBUTION- Dr. V. Jayalakshmi.pdf
 
4087 r01
4087 r014087 r01
4087 r01
 

Smartbank Powercap Mv Me Ss125

  • 1. SmartBank Metal-Enclosed ™ Power Capacitor Banks Medium Voltage • Fully Configurable Look to Maysteel for the finest in medium-voltage, metal-enclosed banks having capacitive reactive power ratings up to 30 MVAR in a single enclosure. These robust units are designed to improve power factor in a variety of industrial, com- mercial and utility applications. Both fixed designs and automatically switched designs (up to 20 steps) are available, in system voltages from 2.4 kV through 34.5 kV RMS. Metal-enclosed versions are designed for substation use; pad-mount versions are for use in publicly accessible areas. Other major features include: • Free-standing, heavy-gauge, compartmentalized Maysteel enclosures • Both front and rear doors for easy accessibility • Integral control and protection systems • Short circuit ratings to 61 kA RMS symmetrical • Fused main disconnect switch or interlock with grounding switch • Available fully assembled, or shipped in sections for field assembly • All equipment meets or exceeds ANSI, IEEE, NEC and NESC standards ISO 9001 CERTIFIED Electric Power Products
  • 2. Viewing windows available as option. Enclosure Easy access Features control cabinet. Doors equipped with three-point latching mechanism, padlockable handles. Mesh-backed ventilation louvers allow filters to be changed without opening enclosure. Key interlock system ensures safety through proper sequence Robust, formed-channel base simplifies of operation. installation, allowing single-piece shipments in lengths up to 50 feet; constructed of 7 gauge hot-rolled steel or 304L stainless steel (optional). • Standard construction: 12 gauge hot rolled steel construction, pickled and oiled ASTM A569, Type 1010. • Optional constructions: 11 gauge hot rolled steel Galvanneal A60 grade Aluminum 304L or 316 stainless steel • Polyester powder coat finish. Available colors: Gray – ANSI 61, Munsell 8.3BG 6.10/0.54 Gray – ANSI 70, Munsell 5BG 7.0/0.4 Green – Munsell 7GY 3.29/1.5 • Degrees of protection: NEMA 3R standard; NEMA 1, 4X, 12 and 13 optional. • Fan system in NEMA 1 and 3R enclosures; air conditioning in NEMA 4X, 12 and 13. • Stainless steel hinges, hinge pins, fasteners and associated hardware. • Doors on front and rear of enclosure for easy access. Seam cap, drip edge and pitched roof provide maximum • Control compartment equipped with thermostatically controlled heater rain protection. and GFI duplex outlet. • Interior lighting in control compartment, main disconnect compartment and all compartments containing medium-voltage power components.
  • 3. Electrical Features Controllers can switch stages based on current, power factor, temperature, Main fuses provide time or voltage. over-current protection to main bus, back-up protection to power components. AUtO / OFF / ON Arresters protect from transient switches, and Stage over-current caused by lightning or OFF and Stage ON switching. Heavy-duty distribution press-to-test pilot lights. class arresters standard; intermediate station class optional. Fused control power transformer is located ahead of main disconnect, allowing control and protection circuits to be tested before main power is applied. Main disconnect switch, located in isolated compartment, allows arresters, main fuses and other components to be serviced without the need to disconnect power to the feed bus. Metal-Enclosed, Power Capacitor Banks
  • 4. Air-insulated, load-break main disconnect switch equipped with mechanically interlocked ground switch, which grounds the load-side for safety during maintenance. External operation provides the visible break required by National Electrical Code. Copper power bus rated at 1,000 amperes RMS per inch2 throughout. Ground switch transient Inrush Reactors Multi-stage power capacitor banks are equipped with air-core, dry-type, single- phase transient inrush reactors that reduce the frequency and magnitude of the inrush current that result from back-to-back switching of stages.
  • 5. Capacitor banks are configured ungrounded wye standard, delta or grounded wye optional. Externally fused units are standard, internally fused available upon request. All capacitors use environmentally friendly, biodegradable dielectric fluid with no PCB content. Internal discharge resistors reduce residual voltage to less than 50 volts within five minutes of de-energizing. low-loss, double-bushing capacitor units meet or exceed IEC 871 and IEEE Standard 18. Rear-entry doors provide easy access to capacitor units; simple capacitor mounting system facilitates removal and change-out. Each capacitor unit is protected against case rupture by a current-limited fuse with a 63kA RMS symmetrical interrupting capacity. Stages are controlled by single-phase vacuum switches (pictured), single-phase oil switches, three-phase vacuum interrupters or three-phase vacuum contactors. Automatic detection system provides both local and remote indication that one or more capacitor unit fuses in a stage has operated. Electric Power Products
  • 6. Typical Capacitor Bank Schematic Power Capacitor Bank Power Capacitor Ground Switch Unit Fuses Power Capacitor Units Transient Inrush S2 Main Disconnect Reactors, Optional Switch C1 F1 S1 L1 A C2 F2 MOV1 C3 F3 Power Input L2 B C4 F4 MOV2 C5 F5 L3 C C6 F6 MOV3 Arresters CT1 CPT1 Control Power Neutral Current Transformer, Transformer to Neutral Unbalance Relay Representative Applications • Wind farms • Oil refineries • Utility substations www.maysteel.com MAyStEEl Electric Power Products W142 N9041 Fountain Blvd. , Menomonee Falls, WI 53051 PO Box 1240, Menomonee Falls, WI 53052-1240 • Phone 877/219-9728 • Fax 262/251-0069 © 2007 Maysteel, LLC SS125 - 2/07