SlideShare a Scribd company logo
1 of 6
Download to read offline
Cyclone Xi™              ®

                                                        ®
                         Commercial Gas Water Heaters




224400 AOSCG0100 Web 1                                      4/27/10 11:48:56 AM
Think Tank
            For years, A. O. Smith has set the industry      Now with a broader line to choose from, high
            standard for performance and quality in          thermal efficiency, superior tank protection
            heavy-duty commercial applications. The latest   and the new intelligent control system, the
            enhancement to the groundbreaking Cyclone        Cyclone Xi is not only the benchmark in the
            family, Cyclone® Xi™ has taken water heater      high efficiency commercial water heating
            functionality, performance and                                category—it’s simply the smartest
            design to a whole new level.                                  water heater ever made.




224400 AOSCG0100 Web 2                                                                                   4/27/10 11:49:18 AM
AT A GLANCE
                                         ■ Intelligent Control System with LCD display

                                                 iCOMM™ compatible and can be monitored from

                                                 remote locations. Call 1.888.WATER02 for more

                                                 information. iCOMM system available for BTX-100

                                                 and BTH-120-BTH-500 models

                                         ■ Models ranging from 50-gallon / 76,000 BTU to
                                            130-gallon / 500,000 BTU with up to 96% thermal efficiency

                                         ■ Venting flexibility for versatility and easy serviceability

                                         ■ Industry-first powered anodes for superior tank protection

                                         ■ Exclusive PermaGlas® Ultra Coat ™ glass lining

                                   TC

                                        Total Control               TC

                                        Cyclone Xi® LCD
                                        The intelligent control system, with
                                        easy to navigate menu, provides
                                        precise temperature control and
                         PA   PA        unit operating information.

                                         ■ Detailed heater status                    ■ Maintains constant log of the
                                            information: blower, igniter,              number of cycles and burner
                                            igniter current, gas valve, flame          operating time
                                            detection, air inlet restrictions,
                                            exhaust vent restrictions,               ■ Communicates fault details and
                                            acceptable gas supply pressure             gives diagnostic information

                                         ■ Precise temperature setting               ■ Maintains a log of any fault
                                            with actual tank temperature               occurrence and the time a
                                            at upper and lower probes                  fault occurred

                                         ■ Alerts the user to any potential
                                            corrosion-related leak




                                                                                     ■ Provides superior tank protection
                                        Powered Anodes*                         PA
                                                                                       to traditional aluminum or
                                                                                       magnesium anodes
                                        The A. O. Smith powered
                                        anode system provides the                    ■ Power level adjusts to changes

                                        most modern and innovative                     in water conditions for
                                                                                       optimum protection
                                        technology available to provide
                                        long-lasting tank protection.                ■ Offers superior protection in
                                                                                       various water conditions
                                        *Not on 76,000 and 100,000 BTU models
                                                                                       — Better protection in water
                                          ■ Non-sacrificial anode does                    with low conductivity
                                            not require maintenance                    — Eliminates the occurence of
                                            or inspection                                hydrogen sulfide gas production
                                                                                         (rotten egg odor)




224400 AOSCG0100 Web 3                                                                                                     4/27/10 11:49:32 AM
COMMERCIAL WATER HEATERS

                         The Breadth Of Innovation

                             UNRIVALED VENTING VERSATILITY

                             The Cyclone ® Xi™ features power-vent and power direct-vent design, allowing clean
                             uncontaminated air to be drawn directly into the unit with the flue gas products vented
                             conventionally through the ceiling or directly through the wall to the outside.

                             Sealed Direct Vent Vertical             Sealed Direct Vent Sidewall            Indoor Conventional Vertical         Indoor Conventional Sidewall




                                           4˝ Vent                                                                            4˝ Vent
                                                                                     4˝ Vent                                                                            4˝ Vent
                                           120´ Intake                                                                        120´ Exhaust
                                                                                     120´ Intake                                                                        120´ Exhaust
                                           120´ Exhaust                              120´ Exhaust

                                 3´ Vent                                   3˝ Vent                                  3˝ Vent                            3˝ Vent
                                 50´ Intake                                50´ Intake                               50´ Exhaust                        50´ Exhaust
                                 50´ Exhaust                               50´ Exhaust

                                       Chart applies to BTH -120 through BTH-250 models only • 4˝ PVC required on BTH 300-500 for up to 70 equivalent feet of venting




                         EASIER TO INSTALL
                         Because installation space today is almost always at a premium, we’ve designed the Cyclone to install in
                         an absolute minimum of space. The exhaust outlet and fresh air intakes are positioned so the water
                         heater can be placed either in a corner or against a wall.



                         ADVANCED GLASS LINING TECHNOLOGY
                         Exclusive PermaGlas® Ultra Coat™ glass lining protects all Cyclone
                         water heaters. PermaGlas Ultra Coat provides superior protection for
                         all inner tank surfaces, as well as for the inside of the heat exchanger,
                         which would otherwise be vulnerable to corrosion from flue gas
                         condensate. The innovative helical coil minimizes weld points to
                         extend tank life.




                                                                                  STRENGTH IN NUMBERS
                                                                                  Cyclone Xi water heaters can be installed in manifolded
                                                                                  multiples to serve the highest demand applications in place of
                                                                                  boiler systems. For example, four BTH-500s can be manifolded
                                                                                  to provide total storage of 520 gallons with an input of
                                                                                  2,000,000 BTU.




224400 AOSCG0100 Web 4                                                                                                                                                                 4/27/10 11:49:34 AM
The Innovation
            That Started It All
            REVOLUTIONARY HEAT EXCHANGER
            AND BURNER SYSTEMS
            The helical internal heat exchanger in all Cyclone
            models swirls the hot gases, like a cyclone, against the
            heat exchanger walls. This cyclonic action produces an
            extra-high rate of heat transfer, resulting in extra-
            high thermal efficiency. All Cyclone Xi models employ
            an ingenious top-mounted down-fire pre-mix burner,
            resulting in even higher efficiencies.

            This exclusive design delivers 95% thermal efficiency on
            the BTH-120 through BTH - 250 and with the BTH - 500.
            The BTX-100, BTH - 300 and BTH- 400 boost efficiency
            to up to 96%.




            CYCLONE® Xi™ MODELS USE THE LATEST IN BURNER TECHNOLOGY
            A. The pre-mixed burner design delivers                    C. The resulting hot flue gases are then
               maximum efficiency.                                        forced at high velocity through a helical
                                                                          heat exchanger coil.
            B. When the mixture is ignited by the hot
               surface igniter, a swirling flame shoots                D. The spiral shape of the coil keeps the hot
               downward into the submerged central                        gases swirling against the heat exchanger
               combustion chamber.                                        walls, resulting in extra-high thermal efficiency.




            Cyclone® HE
            The light-commercial Cyclone HE is designed to
            produce more hot water than any comparable
            commercial gas water heater available today. The
            power-vent Cyclone HE combines the power of
            76,000 BTU input with 90% thermal efficiency. The
            Cyclone HE is perfect for drive-through or fast food
            restaurants, offices and other light-duty applications.
            It provides the technology and performance that
            lives up to the A. O. Smith standard.




224400 AOSCG0100 Web 5                                                                                                         4/27/10 11:49:43 AM
Model              Gallon                 BTU/                            First Hour                  Recovery In GPH                    Height     Diameter
                                       Capacity              Hr. Input                          Delivery                     @ 100˚ Rise                     (Inches)    (Inches)
                                                       Natural         LP                  Natural          LP              Natural     LP

                    BTX-80*                50          76,000          NA                    118           NA                   83          NA                  70 5/8     22

                    BTX-100                50          100,000     100,000                   164           164                 116          116                 68 1/2     22

                    BTH-120                60          120,000     120,000                   180           180                 138          138                 55 1/2    27 3/4

                    BTH-150               100          150,000     150,000                   243           243                 173          173                 75 1/2    27 3/4

                    BTH-199               100          199,000     199,000                   300           300                 230          230                 75 1/2    27 3/4

                    BTH-250               100          250,000     250,000                   358           358                 288          288                 75 1/2    27 3/4

                    BTH-300               130          300,000     300,000                   440           440                 349          349                 75 1/2    33 1/8

                    BTH-400               130          399,900     399,900                   557           557                 466          466                 75 1/2    33 1/8

                    BTH-500               130          499,900     499,900                   667           667                 576          576                 75 1/2    33 1/8

                                                                                                    * Power-vent only—see spec sheet for details.




                                                                                                   Commercial Gas Water Heaters
                                                                                                   INNOVATIVE SOLUTIONS FOR ALL

                                                                                                   The expanded Cyclone® line gives you a high-efficiency
                                                                                                   commercial water heater choice for almost any
                                                                                                   commercial application.


                                                                                                   For complete specifications on Cyclone HE and Cyclone Xi,
                                                                                                   consult Specification Sheets at www.hotwater.com.




                                                                                                                          ®



                                                                        A.O. Smith Water Products Company
                                                                 500 Tennessee Waltz Parkway Ashland City, TN 37015
                                                                                 www.hotwater.com


            AOSCG01000 ©2010 A. O. Smith Corporation             A. O. Smith reserves the right to make product changes or improvements at any time without notice.          Printed in U.S.A
            Revised April 2010




224400 AOSCG0100 Web 6                                                                                                                                                                   4/27/10 11:50:33 AM

More Related Content

What's hot

Honeywell fg1625f-data-sheet
Honeywell fg1625f-data-sheetHoneywell fg1625f-data-sheet
Honeywell fg1625f-data-sheetAlarm Grid
 
Sp30 perkins 30kva Groupe électrogène standby single phase data sheet
Sp30 perkins 30kva Groupe électrogène standby single phase data sheetSp30 perkins 30kva Groupe électrogène standby single phase data sheet
Sp30 perkins 30kva Groupe électrogène standby single phase data sheetSUNSHINE MACHINERY
 
Điều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTUĐiều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTUMyravn1
 
Virtis bench top k series (brochure)
Virtis   bench top k series (brochure)Virtis   bench top k series (brochure)
Virtis bench top k series (brochure)amteclab
 
Máy lạnh Daikin âm trần
Máy lạnh Daikin âm trầnMáy lạnh Daikin âm trần
Máy lạnh Daikin âm trầnMyLnhGiGc
 
Bảng giới thiệu điều hòa Multi Daikin
Bảng giới thiệu điều hòa Multi DaikinBảng giới thiệu điều hòa Multi Daikin
Bảng giới thiệu điều hòa Multi DaikinMyravn1
 
Greenhouse Datasheet4
Greenhouse Datasheet4Greenhouse Datasheet4
Greenhouse Datasheet4julianguo
 
Natgraph Air Force Dryers & Options
Natgraph Air Force Dryers & OptionsNatgraph Air Force Dryers & Options
Natgraph Air Force Dryers & OptionsNatgraph
 
CS Unitec Chain Saws Catalog Pages
CS Unitec Chain Saws Catalog PagesCS Unitec Chain Saws Catalog Pages
CS Unitec Chain Saws Catalog PagesCS Unitec
 
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) LightingAbtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) LightingThorne & Derrick International
 

What's hot (20)

Oxygen Gas Plants India
Oxygen Gas Plants IndiaOxygen Gas Plants India
Oxygen Gas Plants India
 
Oxygen Gas Plants
Oxygen Gas PlantsOxygen Gas Plants
Oxygen Gas Plants
 
Sp33 data sheet
Sp33 data sheetSp33 data sheet
Sp33 data sheet
 
Honeywell fg1625f-data-sheet
Honeywell fg1625f-data-sheetHoneywell fg1625f-data-sheet
Honeywell fg1625f-data-sheet
 
Sl128 lovol data sheet s
Sl128 lovol data sheet sSl128 lovol data sheet s
Sl128 lovol data sheet s
 
Sp30 perkins 30kva Groupe électrogène standby single phase data sheet
Sp30 perkins 30kva Groupe électrogène standby single phase data sheetSp30 perkins 30kva Groupe électrogène standby single phase data sheet
Sp30 perkins 30kva Groupe électrogène standby single phase data sheet
 
Điều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTUĐiều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTU
 
Virtis bench top k series (brochure)
Virtis   bench top k series (brochure)Virtis   bench top k series (brochure)
Virtis bench top k series (brochure)
 
Air techbook en
Air techbook enAir techbook en
Air techbook en
 
Máy lạnh Daikin âm trần
Máy lạnh Daikin âm trầnMáy lạnh Daikin âm trần
Máy lạnh Daikin âm trần
 
Bảng giới thiệu điều hòa Multi Daikin
Bảng giới thiệu điều hòa Multi DaikinBảng giới thiệu điều hòa Multi Daikin
Bảng giới thiệu điều hòa Multi Daikin
 
Greenhouse Datasheet4
Greenhouse Datasheet4Greenhouse Datasheet4
Greenhouse Datasheet4
 
Smi1500 60 mitsubishi generator
Smi1500 60 mitsubishi generatorSmi1500 60 mitsubishi generator
Smi1500 60 mitsubishi generator
 
Natgraph Air Force Dryers & Options
Natgraph Air Force Dryers & OptionsNatgraph Air Force Dryers & Options
Natgraph Air Force Dryers & Options
 
Sc1000 cummins
Sc1000 cumminsSc1000 cummins
Sc1000 cummins
 
CS Unitec Chain Saws Catalog Pages
CS Unitec Chain Saws Catalog PagesCS Unitec Chain Saws Catalog Pages
CS Unitec Chain Saws Catalog Pages
 
Sp24 data sheet
Sp24 data sheetSp24 data sheet
Sp24 data sheet
 
Sl150 lovol generator set
Sl150 lovol generator setSl150 lovol generator set
Sl150 lovol generator set
 
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) LightingAbtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
Abtech Lighting - Hazardous Area Zone 1 Zone 2 (ATEX IECEx) Lighting
 
Chronomite Laboratories, Inc.
Chronomite Laboratories, Inc.Chronomite Laboratories, Inc.
Chronomite Laboratories, Inc.
 

Similar to Ao cyclone xi brochor

Kazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hgKazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hgguestb585ef
 
Vacon NXP Liquid Cooled
Vacon NXP Liquid CooledVacon NXP Liquid Cooled
Vacon NXP Liquid CooledVacon Plc
 
Siemens Sivacon S8 Info
Siemens Sivacon S8 InfoSiemens Sivacon S8 Info
Siemens Sivacon S8 Infonor52097
 
Marine incinerator-tb-ab-aqua-datasheet
Marine incinerator-tb-ab-aqua-datasheetMarine incinerator-tb-ab-aqua-datasheet
Marine incinerator-tb-ab-aqua-datasheetaddfield
 
Active Beam Commissioning Overview
Active Beam Commissioning   OverviewActive Beam Commissioning   Overview
Active Beam Commissioning OverviewDarren_Alexander
 
Flexible Cables Solution
Flexible Cables SolutionFlexible Cables Solution
Flexible Cables Solutionprysmianaus
 
datasheets on radiant heaters
datasheets on radiant heatersdatasheets on radiant heaters
datasheets on radiant heaterslahja7ti
 
radiant heater datasheets
radiant heater datasheetsradiant heater datasheets
radiant heater datasheetsdanc6ct7be
 
Help with radiant heating
Help with radiant heatingHelp with radiant heating
Help with radiant heatingjonad9qobe
 

Similar to Ao cyclone xi brochor (20)

Kazakistan references
Kazakistan referencesKazakistan references
Kazakistan references
 
Kazakistan references
Kazakistan references   Kazakistan references
Kazakistan references
 
Gürcistan references
Gürcistan referencesGürcistan references
Gürcistan references
 
Gürcistan references
Gürcistan referencesGürcistan references
Gürcistan references
 
Gürcistan references
Gürcistan referencesGürcistan references
Gürcistan references
 
Labotron X
Labotron XLabotron X
Labotron X
 
Kazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hgKazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hg
 
Rusya references
Rusya referencesRusya references
Rusya references
 
Vacon NXP Liquid Cooled
Vacon NXP Liquid CooledVacon NXP Liquid Cooled
Vacon NXP Liquid Cooled
 
Siemens Sivacon S8 Info
Siemens Sivacon S8 InfoSiemens Sivacon S8 Info
Siemens Sivacon S8 Info
 
Ax100 tf
Ax100 tfAx100 tf
Ax100 tf
 
Ax200 tf
Ax200 tfAx200 tf
Ax200 tf
 
Marine incinerator-tb-ab-aqua-datasheet
Marine incinerator-tb-ab-aqua-datasheetMarine incinerator-tb-ab-aqua-datasheet
Marine incinerator-tb-ab-aqua-datasheet
 
Active Beam Commissioning Overview
Active Beam Commissioning   OverviewActive Beam Commissioning   Overview
Active Beam Commissioning Overview
 
Azerbaycan references
Azerbaycan referencesAzerbaycan references
Azerbaycan references
 
Flexible Cables Solution
Flexible Cables SolutionFlexible Cables Solution
Flexible Cables Solution
 
Full Line Brochure
Full Line BrochureFull Line Brochure
Full Line Brochure
 
datasheets on radiant heaters
datasheets on radiant heatersdatasheets on radiant heaters
datasheets on radiant heaters
 
radiant heater datasheets
radiant heater datasheetsradiant heater datasheets
radiant heater datasheets
 
Help with radiant heating
Help with radiant heatingHelp with radiant heating
Help with radiant heating
 

Ao cyclone xi brochor

  • 1. Cyclone Xi™ ® ® Commercial Gas Water Heaters 224400 AOSCG0100 Web 1 4/27/10 11:48:56 AM
  • 2. Think Tank For years, A. O. Smith has set the industry Now with a broader line to choose from, high standard for performance and quality in thermal efficiency, superior tank protection heavy-duty commercial applications. The latest and the new intelligent control system, the enhancement to the groundbreaking Cyclone Cyclone Xi is not only the benchmark in the family, Cyclone® Xi™ has taken water heater high efficiency commercial water heating functionality, performance and category—it’s simply the smartest design to a whole new level. water heater ever made. 224400 AOSCG0100 Web 2 4/27/10 11:49:18 AM
  • 3. AT A GLANCE ■ Intelligent Control System with LCD display iCOMM™ compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information. iCOMM system available for BTX-100 and BTH-120-BTH-500 models ■ Models ranging from 50-gallon / 76,000 BTU to 130-gallon / 500,000 BTU with up to 96% thermal efficiency ■ Venting flexibility for versatility and easy serviceability ■ Industry-first powered anodes for superior tank protection ■ Exclusive PermaGlas® Ultra Coat ™ glass lining TC Total Control TC Cyclone Xi® LCD The intelligent control system, with easy to navigate menu, provides precise temperature control and PA PA unit operating information. ■ Detailed heater status ■ Maintains constant log of the information: blower, igniter, number of cycles and burner igniter current, gas valve, flame operating time detection, air inlet restrictions, exhaust vent restrictions, ■ Communicates fault details and acceptable gas supply pressure gives diagnostic information ■ Precise temperature setting ■ Maintains a log of any fault with actual tank temperature occurrence and the time a at upper and lower probes fault occurred ■ Alerts the user to any potential corrosion-related leak ■ Provides superior tank protection Powered Anodes* PA to traditional aluminum or magnesium anodes The A. O. Smith powered anode system provides the ■ Power level adjusts to changes most modern and innovative in water conditions for optimum protection technology available to provide long-lasting tank protection. ■ Offers superior protection in various water conditions *Not on 76,000 and 100,000 BTU models — Better protection in water ■ Non-sacrificial anode does with low conductivity not require maintenance — Eliminates the occurence of or inspection hydrogen sulfide gas production (rotten egg odor) 224400 AOSCG0100 Web 3 4/27/10 11:49:32 AM
  • 4. COMMERCIAL WATER HEATERS The Breadth Of Innovation UNRIVALED VENTING VERSATILITY The Cyclone ® Xi™ features power-vent and power direct-vent design, allowing clean uncontaminated air to be drawn directly into the unit with the flue gas products vented conventionally through the ceiling or directly through the wall to the outside. Sealed Direct Vent Vertical Sealed Direct Vent Sidewall Indoor Conventional Vertical Indoor Conventional Sidewall 4˝ Vent 4˝ Vent 4˝ Vent 4˝ Vent 120´ Intake 120´ Exhaust 120´ Intake 120´ Exhaust 120´ Exhaust 120´ Exhaust 3´ Vent 3˝ Vent 3˝ Vent 3˝ Vent 50´ Intake 50´ Intake 50´ Exhaust 50´ Exhaust 50´ Exhaust 50´ Exhaust Chart applies to BTH -120 through BTH-250 models only • 4˝ PVC required on BTH 300-500 for up to 70 equivalent feet of venting EASIER TO INSTALL Because installation space today is almost always at a premium, we’ve designed the Cyclone to install in an absolute minimum of space. The exhaust outlet and fresh air intakes are positioned so the water heater can be placed either in a corner or against a wall. ADVANCED GLASS LINING TECHNOLOGY Exclusive PermaGlas® Ultra Coat™ glass lining protects all Cyclone water heaters. PermaGlas Ultra Coat provides superior protection for all inner tank surfaces, as well as for the inside of the heat exchanger, which would otherwise be vulnerable to corrosion from flue gas condensate. The innovative helical coil minimizes weld points to extend tank life. STRENGTH IN NUMBERS Cyclone Xi water heaters can be installed in manifolded multiples to serve the highest demand applications in place of boiler systems. For example, four BTH-500s can be manifolded to provide total storage of 520 gallons with an input of 2,000,000 BTU. 224400 AOSCG0100 Web 4 4/27/10 11:49:34 AM
  • 5. The Innovation That Started It All REVOLUTIONARY HEAT EXCHANGER AND BURNER SYSTEMS The helical internal heat exchanger in all Cyclone models swirls the hot gases, like a cyclone, against the heat exchanger walls. This cyclonic action produces an extra-high rate of heat transfer, resulting in extra- high thermal efficiency. All Cyclone Xi models employ an ingenious top-mounted down-fire pre-mix burner, resulting in even higher efficiencies. This exclusive design delivers 95% thermal efficiency on the BTH-120 through BTH - 250 and with the BTH - 500. The BTX-100, BTH - 300 and BTH- 400 boost efficiency to up to 96%. CYCLONE® Xi™ MODELS USE THE LATEST IN BURNER TECHNOLOGY A. The pre-mixed burner design delivers C. The resulting hot flue gases are then maximum efficiency. forced at high velocity through a helical heat exchanger coil. B. When the mixture is ignited by the hot surface igniter, a swirling flame shoots D. The spiral shape of the coil keeps the hot downward into the submerged central gases swirling against the heat exchanger combustion chamber. walls, resulting in extra-high thermal efficiency. Cyclone® HE The light-commercial Cyclone HE is designed to produce more hot water than any comparable commercial gas water heater available today. The power-vent Cyclone HE combines the power of 76,000 BTU input with 90% thermal efficiency. The Cyclone HE is perfect for drive-through or fast food restaurants, offices and other light-duty applications. It provides the technology and performance that lives up to the A. O. Smith standard. 224400 AOSCG0100 Web 5 4/27/10 11:49:43 AM
  • 6. Model Gallon BTU/ First Hour Recovery In GPH Height Diameter Capacity Hr. Input Delivery @ 100˚ Rise (Inches) (Inches) Natural LP Natural LP Natural LP BTX-80* 50 76,000 NA 118 NA 83 NA 70 5/8 22 BTX-100 50 100,000 100,000 164 164 116 116 68 1/2 22 BTH-120 60 120,000 120,000 180 180 138 138 55 1/2 27 3/4 BTH-150 100 150,000 150,000 243 243 173 173 75 1/2 27 3/4 BTH-199 100 199,000 199,000 300 300 230 230 75 1/2 27 3/4 BTH-250 100 250,000 250,000 358 358 288 288 75 1/2 27 3/4 BTH-300 130 300,000 300,000 440 440 349 349 75 1/2 33 1/8 BTH-400 130 399,900 399,900 557 557 466 466 75 1/2 33 1/8 BTH-500 130 499,900 499,900 667 667 576 576 75 1/2 33 1/8 * Power-vent only—see spec sheet for details. Commercial Gas Water Heaters INNOVATIVE SOLUTIONS FOR ALL The expanded Cyclone® line gives you a high-efficiency commercial water heater choice for almost any commercial application. For complete specifications on Cyclone HE and Cyclone Xi, consult Specification Sheets at www.hotwater.com. ® A.O. Smith Water Products Company 500 Tennessee Waltz Parkway Ashland City, TN 37015 www.hotwater.com AOSCG01000 ©2010 A. O. Smith Corporation A. O. Smith reserves the right to make product changes or improvements at any time without notice. Printed in U.S.A Revised April 2010 224400 AOSCG0100 Web 6 4/27/10 11:50:33 AM