SlideShare a Scribd company logo
1 of 9
Download to read offline
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 101
COMPARATIVE STUDY OF RC FRAMED STRUCTURES USING
SPECTRA BASED PUSHOVER ANALYSIS
Pavan Kumar N1
, Avinash Gornale2
, Gargi G S3
, B G Naresh Kumar4
1
PG Student, Dept. of Civil Engineering, BGS Institute of Technology, Mandya District, Karnataka, India
2
Asst. Professor, Dept. of Civil Engineering, Maharaja Institute of Technology, Mysore District, Karnataka, India
3
Asst. Professor, Dept. of Civil Engineering, BGS Institute of Technology, Mandya District, Karnataka, India
4
Prof & Principal, Dept. of Civil Engineering, Maharaja Institute of Technology, Mysore District, Karnataka, India
Abstract
Spectra based multimodal adaptive pushover analysis considers higher modes of vibration and combines them using SRSS rule
and scale factors. Damage index for the structures are calculated to evaluate the degree of damage occurred after a seismic
event. For the present study the Spectra based multimodal adaptive pushover analysis is adopted for G+ 4 storeys Symmetric and
G+ 4 storeys Asymmetric Reinforced concrete framed structures. The Expended Energy based damage index methods are used to
calculate Damage Index for symmetric and asymmetric structures. ETABS 2015 software is utilized for modeling and analysis of
Reinforced concrete framed structures. The comparative studies are carried out between the structure considering only 1st mode
and considering all modes and compared between 3 methods of damage index. It is observed that the capacity obtained by
considering all modes is less than the capacity obtained by considering only 1st mode. The target displacement obtained
considering only 1st mode is less than the target displacement obtained considering all modes. And the damage index obtained by
considering all modes is more than the damage index obtained by considering only 1st mode. Therefore it is necessary to consider
all modes to get accurate results. In asymmetric building the ductility is less, the capacity is less, demand is high, and degree of
damage is more when compared with symmetric building.
Keywords: pushover analysis, damage index, RC frame, multimodal, symmetric and asymmetric
--------------------------------------------------------------------***----------------------------------------------------------------------
1. INTRODUCTION
The Spectra based multimodal adaptive pushover analysis
which is proposed by K. Shakeri, M. Mohebbi Asbmarz and
M.A. Shayanfar 2008[3] is adopted for G+4 storey
Symmetric and G+4 storey Asymmetric building in the
analysis of Reinforced concrete framed structures. The
Expended Energy based damage index methods which is
proposed by Anthugari Vimala, Pradeep Kumar,
Ramancharla (2014) [10] are used to calculate Damage
Index for symmetric and asymmetric structures. ETABS
2015 software is utilized for modelling and analysis of
Reinforced concrete framed structures.
Spectra based multimodal adaptive pushover analysis
considers higher modes of vibration and combines them
using SRSS rule and scale factors. All these factors are very
essential to increase the accuracy of the results. Damage
index for the structures are calculated to evaluate the degree
of damage occurred after a seismic event. The Expended
energy based damage index is represented as ratio of
inelastic energy dissipated at any displacement to the total
inelastic energy capacity of the structure. The energy
method is used to calculate Global damage index of the
structure.
This project work focuses on Evaluation and Comparative
study of damage index of symmetric and asymmetric RC
framed structures using Spectra based multimodal adaptive
pushover analysis.
In our present study we have adopted two example
reinforced concrete framed structures (i) 5 storey symmetric
structure and (ii) 5 storey asymmetric structure. Spectra
based multimodal adaptive pushover analysis used as RC
framed analysis. ETABS 2015 is utilized for modelling and
analysis. Damage indices are calculated and compared with
symmetrical and asymmetrical structures.
2. MODELS CONSIDERED FOR STUDY
2.1 Symmetric Model
A G+4 storey, 7-bay by 2-bay symmetrical reinforced
concrete framed residential building is considered.
Dimension of
Column
0.23 X 0.4 m
Dimension of Beam 0.23 X 0.35 m
Thickness of slab 0.125 m
Thickness of wall 0.23 m
Soil type II
Live load 2 KN/m
Location of building Mysore, Karnataka, India.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 102
Fig 1 Plan of Symmetric Building
Fig 2 3D View of Symmetric Building
2.2 Asymmetric Model
An Asymmetrical residential building is as shown in figure
below.
Dimension of column 0.23 X 0.4 m,
Beam 0.23 X 0.35m
Thickness of slab 0.125 m
Thickness of wall 0.23 m
Soil type II
Live load 2 KN/m
Location of Building Mysore, Karnataka, India.
Fig 3 Plan of Asymmetric Building
Fig 4 3D View of Asymmetric Building
3. SUMMARY OF ANALLYSIS IN ETABS 2015
1. Create the model with nonlinear properties.
2. Set the maximum number of modes as the number of
stories multiplied by 3 for 3D Analysis.
3. Perform gravity analysis and modal analysis. From
modal analysis result the direction of modes (weather
X-direction or Y-direction) are obtained.
4. In case of asymmetric structures it is needed to
calculate the eccentricity ratio in each storey and apply
it to lateral load pattern.
5. Define the nonlinear load case for each mode
separately in X or Y direction according to the
direction of mode.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 103
6. Perform pushover analysis and note down the
maximum base shear in each mode and combine them
by SRSS rule.
7. Calculate scale factor for each mode and apply them to
nonlinear load cases in each mode.
8. Again perform pushover analysis, resulting base shears
are combined by SRSS rule and scale factors are
calculated.
9. Apply these scale factors to a separate nonlinear load
case which contain all the mode in X and Y direction
with above computed scale factor and perform
pushover analysis.
10. From bilinear pushover curve we can obtain target
displacement. Compare target and monitored
displacement with applied displacement in the
nonlinear load case, if target displacement is more than
applied load case then apply target displacement as
applied load and perform the final pushover analysis.
11. Calculate damage index for the structure from the
pushover curve results using,
𝐷1 =
𝐸 − 𝐸𝑖𝑒
𝐸 𝑇 − 𝐸𝑖𝑒
× 100
𝐷2 =
𝐸 − 𝐸𝑒
𝐸 𝑇 − 𝐸𝑖𝑒
× 100
𝐷3 =
𝐸𝐿 − 𝐸 𝑁𝐿
𝐸𝐿𝑇 − 𝐸 𝑁𝐿𝑇
× 100
Where,
𝐷1 , 𝐷2 𝑎𝑛𝑑𝐷3 Are Damage index for method 1, method 2
and method 3 respectively.
E = Energy dissipated at which damage is being estimated,
𝐸𝑖𝑒 = Initial yield energy of structure;
𝐸 𝑇 = Total energy absorbed by structure;
𝐸𝑒 = Instantaneous elastic energy at which damage is being
estimated
𝐸𝐿= Linear energy at displacement level at which damage is
being estimated;
𝐸 𝑁𝐿 = Nonlinear energy at which damage is being estimated;
𝐸𝐿𝑇= Linear energy at maximum displacement of structure;
𝐸 𝑁𝐿𝑇 = Nonlinear energy at maximum displacement of
structure
4. RESULTS AND DISCUSSIONS
4.1 Pushover Curve Results
The 1st
mode reaches ultimate yielding point at 181.7 mm,
1216.5638 KN whereas final combined load case reach
ultimate yielding point at 105.3 mm, 98.4257 KN. Here it
can be observed that by considering all the modes, the
capacity of the structure is decreased by 43% when
compared with only one mode. Hence adopting spectra
based adaptive multimode analysis is very useful in getting
accuracy of the results which include all the modes.
Ductility of symmetric building is more when compared to
asymmetric structure.
Symmetric structure shows post yielding behavior and also
strength degradation behavior.
Asymmetric structure is showing post yielding behavior but
there is no strength degradation behavior this shows that
asymmetric structure is undergoing brittle failure of
structural members.
Fig 5 Pushover Curve For Symmetrical Structure At Mode-
1 In X-Direction
Fig 6 Pushover Curve For Symmetrical Structure By
Combining All Modes In X-Direction
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 104
Fig 7 Pushover Curve For Asymmetrical Structure At
Mode-1 In Y-Direction
Fig 8 Pushover Curve For Asymmetrical Structure With
Combined Loading In Y-Direction
4.2 𝐒 𝐚 𝐯𝐬 𝐒 𝐝 Curve Results
Fig 9 Sa vs Sd Curve For Symmetric Structure At Mode-1 In
X-Direction
Fig 10 Sa vs Sd Curve For Symmetric Structure For
Combined Load Case In X-Direction
Fig 11 Sa vs Sd Curve For Asymmetric Structre At Mode-1
In Y-Direction
Fig 12 Sa vs Sd Curve For Asymmetric Structure For
Combined Load Case In Y-Direction
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 105
In symmetric structure the performance point is found only
in mode-1. The displacement at performance point in mode-
1 is 340.8 mm. and in all modes the displacement at
performance point 565.9 mm which means participation of
mode-1 in the analysis is more than any other modes. But
other 40% cannot be neglected, thus we need to consider all
the modes for combined effect.
In asymmetric structure the performance point is found only
in mode-4. The maximum displacement occurred in mode-4
is 34.3 mm. In final result also there is no meet of point
observed. Therefore it is very much necessary to adopt
spectra based adaptive multimodal pushover procedure to
know the changes in behavior of structure at different
modes. Hence this method help to choose peak performance
results for the design of structure.
From the above results the capacity of the symmetric
structure is greater when compared with asymmetric
structure.
4.3 Bilinear Curve Results
Target displacements obtained are used in the design of
structure.
In symmetric model first mode represents the target
displacement of 378.3mm whereas all modes combined final
target displacement is 523.4mm. Here it can be observed
that 27% less target displacement is obtained when
considering only 1st
mode. Therefore considering all the
mode is important to get accurate results and good design.
In symmetric model the target displacement is within the
capacity of the structure whereas in asymmetric model the
target displacement is beyond the capacity of the structure.
Fig 13 Bilinear Pushover Curve For Symmetric Structure At
Mode-1 In X-Direction
Fig 14 Bilinear Pushover Curve For Symmetric Structure
For Combined Load Case In X-Direction
Fig 15 Bilinear Pushover Curve For Asymmetric Structure
At Mode-1 In Y-Direction
Fig 16 Bilinear Pushover Curve For Asymmetric Structure
For Combined Load Case In Y-Direction
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 106
4.4 Hinge State Results
Table 1 Performance Level
PERFORMANCE
LEVEL
DESCRIPTION
Operational Level (OL) Building will be under
construction. Minor repairs may
be required.
Immediate occupancy
level (IO)
Building will be available to
accommodate.
Life safety level (LS) Very low chances of collapse of
structural members.
No harm to life occurs.
Collapse prevention
level (CP)
This requires stability under
vertical loads.
Fig 17 Hinge State For Symmetrical Structure At Mode-1 in
X-Direction
Fig 18 Hinge State For Symmetrical Structure For
Combined Load Case In X-Direction
Fig 19 Hinge State For Asymmetrical Structure At Mode-1
In Y-Direction
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 107
Fig 20 Hinge State For Asymmetrical Structure For
Combined Load Case In Y-Direction
In symmetrical structure, the first mode contain total of
1165 hinges of which 1075 hinges are in immediate
occupancy level, 42 hinges are in life safety level, 0 in
collapse prevention level and 48 are beyond collapse
prevention level. When all modes combined case results
contain total of 1165 hinges of which 1081 hinges are in
immediate occupancy level, 36 hinges are in life safety
level, 0 in collapse prevention level and 48 are beyond
collapse prevention level.
Thus in spectra based adaptive multimodal analysis, the
behavior of the structure in every single step of analysis can
be observed.
The failure of hinges occurs first where the columns are
placed closely. Therefore columns should be placed at equal
distances as far as possible.
The failure of hinges starts at bottom storey and gradually
transfers to upper stories with each mode.
4.5 Damage Index Results
Table 2 Ranges Of Damage Index (Dorde Ladinovic,
Aleksandra Radujkovic, Andrija Raseta (2011) [16])
Degree of damage Damage index State of structure
Minor 0.0-0.2 Serviceable
Moderate 0.2-0.5 Repairable
Severe 0.5-1.0 Irreparable
Collapse >1.0 Loss of building
Table 3 Damage Index For Symmetric Structure
DAMAGE INDEX FOR SYMMETRICAL STRUCTURE
Mode no. METHOD
1
METHOD
2
METHOD
3
PX1 0.230776 0.166491 0.023737
PX4 0.162262 0.131261 0.016884
PX7 1 0.004032 1
PX10 0.14566 0.135823 0.013773
PX11 0.947425 0.23723 2.468422
PY2 0.966751 0.732177 1.072819
PY5 1 0.269953 1
PY8 1 0.185354 0.28759
PY13 1 0.819354 1
PY14 0.809682 0.33357 2.834754
OVERALL
DAMAGE
INDEX IN
X-DIRECTION
0.1362 0.09985 0.01345
OVERALL
DAMAGE
INDEX IN
Y-DIRECTION
0.6663 0.1907 0.5262
Table 4 Damage Index For Asymmetric Structure
DAMAGE INDEX FOR ASYMMETRICAL
STRUCTURE
Mode no. METH
OD 1
METHOD
2
METHOD
3
PX3 0.3490
08
0.347986 2.274995
PX6 1 0.680699 1
PX10 1 0.124079 1
PX13 1 0.516721 1
PX15 0.9322
06
0.580708 0.76984
PY1 1 0.601102 1
PY4 1 0.677741 1
PY7 1 N/A 1
PY9 0.5712
56
0.432167 1.42617
PY11 0.8492
1
0.745895 1.086192
OVERALL
DAMAGE
INDEX IN
X-DIRECTION
1 0.52 1
OVERALL
DAMAGE
INDEX IN
Y-DIRECTION
1 0.628 1
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 108
The higher value of damage index is observed in all modes
combined case when compared with the damage index by
considering only 1st
mode. Therefore to get accurate results,
all the modes need to be considered.
The severe and collapsed state is observed more in
asymmetric model than symmetric model. Therefore as the
asymmetry increases the damage also increase.
Out of three methods, the Method 1 and Method 3 is
indicating little higher degree of damage when compared
with Method 2.
5. CONCLUSION
From the pushover curve results it is observed that the
capacity of the structure obtained by considering all modes
is less than the capacity obtained by considering only 1st
mode. Hence adopting spectra based adaptive multimode
analysis is very useful in getting more accurate results.
By adopting asymmetric structure over symmetric structure
the ductility of structure may be compromised. Hence
suitable precautionary measures should be taken while
adopting asymmetric structures.
In symmetric model the capacity is meeting the demand of
the building where as in asymmetric model the demand is
very high. Thus we can conclude that, as the asymmetry of
structure increases the capacity of the structure decreases.
From bilinear curve results it is observe that target
displacement obtained considering only 1st
mode is less than
the target displacement obtained considering all modes.
Therefore considering all the modes is important to get
accurate results and good design.
More number of hinges reach failure in asymmetric model
when compared with symmetric model. Failure occurs early
where columns are placed closely. Therefore columns
should be placed at equal interval as far as possible.
The higher value of damage index is obtained by
considering all modes when compared with considering only
1st
mode. Therefore to get accurate results we need to
consider all the modes.
The severe and collapsed state of damage is observed more
in asymmetric model than in symmetric model. Therefore as
the asymmetry increases the damage also increase.
Out of three methods of damage index, the Method 1 and
Method 3 is indicating little higher degree of damage when
compared with Method 2.
REFERENCES
[1] IS 1893 (Part 1): 2002, Criteria for earthquake resistant
design of structures. Bureau of Indian Standard, Manak
Bhavan, New Delhi, India.
[2] Rahul Rana, Limin Jin, and Atila Zekioglu (2004).
Pushover analysis of a 19 storey concrete shear wall
building. 13th
world conference on earthquake
engineering, Vancouver B.C Canada.
[3] K. Shakeri, M.A. Shayanfar and M. Mohebbi Asbmarz
(2008). A SPECTRA-BASED MULTI MODAL
ADAPTIVE PUSHOVER PROCEDURE FOR
SEISMIC ASSESSMENT OF BUILDINGS. The 14th
World Conference on Earthquake Engineering October
12-17, 2008, Beijing, China.
[4] Yousuf Dinar, Md. Imam Hossain, Rajib Kumar
Biswas, Md. Masud Rana. Descriptive study of
pushover analysis in RCC structures of rigid joint.
IOSR Journal of Mechanical and Civil Engineering
(IOSR JMCE) ISSN: 2278-1684 Volume 11, Issue 1
(January-February), PP 60-68.
[5] J.R. Qian, W.J. Zhang, and X.D. Ji (2008). Application
of pushover analysis on earthquake response
predication of complex large-span steel structures. The
14th
World Conference on Earthquake Engineering
October 12-17, 2008, Beijing, China.
[6] Philip DE GUZMAN1 and Yuji ISHIYAMA (2004).
Collapse assessment of building structures using
damage index. 13th World Conference on Earthquake
Engineering Vancouver, B.C., Canada August 1-6,
2004 Paper No. 0734.
[7] Tathagata Roy and Dr. Pankaj Agarwal (2014).
Damage Index of Reinforced Concrete Structures in
India. International Journal of Research (IJR) Vol-1,
Issue-5, June 2014.
[8] Saurabh Shiradhonkar and Ravi Sinha (2012). Detailed
evaluation of available seismic damage indices. A
project report, IITR.
[9] Sumit R. Thakur, Sudhir P.Patil, Dr.Keshav K.Sanagle.
Evaluation of damage index of high rise building using
nonlinear static seismic analysis. International Journal
of Emerging Technology and Advanced Engineering
Volume 2, Issue 10, October 2012.
[10] ANTHUGARI VIMALA and PRADEEP KUMAR
RAMANCHARLA (2014). Expended energy based
damage assessment of RC bare frame using nonlinear
pushover analysis. Urban Safety of Mega Cities in
Asia 2014 (USMCA 2014).
[11] Chopra, A.K. and Goel, R.K. (2002). A modal
pushover analysis procedure for estimating seismic
demands for buildings. Earthquake Engineering and
Structural Dynamics, 31, 561-582.
[12] Aydinoglu M.N. (2003). An incremental response
spectrum analysis procedure based on inelastic spectral
displacements for multi-mode seismic performance
evaluation. Bulletin of Earthquake Engineering, 1, 3-
36.
[13] Kalkan, E. and Kunnath S.K. (2006). Adaptive modal
combination procedure for nonlinear static analysis of
building structures. Journal of Structural Engineering,
ASCE, 132:11, 1721-1731.
[14] R. Sinha & S. R. Shiradhonkar. Seismic Damage Index
for Classification of Structural Damage – Closing the
Loop. 15th
World Conference on Earthquake
Engineering, Lisboa 2012.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 109
[15] Young J. Park, Anderi M. Reiniorn, and Shashi K.
Kunnath. Seismic damage analysis of reinforced
concrete buildings. 9th
World Conference on
Earthquake Engineering, August 2-9, 1988, Tokyo-
Kyoto, Japan (Vol. VII).
[16] Dorde Ladinovic, Aleksandra Radujkovic, Andrija
Raseta. Seismic performance assessment based on
damage of structures – part 1: theory. FACTA
UNIVERSITATIS Series: Architecture and Civil
Engineering Vol. 9, No 1, 2011, pp. 77 – 88
BIOGRAPHIES
Mr. Pavan Kumar N, is a Final Year PG
Student, pursuing his Master of
Technology in Structural Engineering
from BGS Institute of Technology,
Mandya District, Karnataka, India.
Mr. Avinash Gornale BE, M.Tech is
working as an Assistant Professor in
department of civil engineering in
Maharaja Institute of Technology,
Mysore, Karnataka. His areas of research
interest include Earthquake engineering
and Performance Evaluation.
Ms. Gargi G S BE, M.Tech is working as
an Assistant Professor in department of
civil engineering in BGS Institute of
Technology, Mandya District, Karnataka,
India. BE and M.Tech in CAD Structures
from PES, Mandya.
Dr. B G Naresh Kumar B.E., M.E., Ph.D.
working as Principal in Maharaja Institute
of Technology, Mysore, Karnataka. ME &
Ph.D. from IIT Kharagpur. In the past he
worked as Legal Advisor for AICTE, New
Delhi.

More Related Content

What's hot

Design evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobileDesign evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobile
eSAT Journals
 
Seismic vulnerability of flat plate column joint with out slab shear reinforc...
Seismic vulnerability of flat plate column joint with out slab shear reinforc...Seismic vulnerability of flat plate column joint with out slab shear reinforc...
Seismic vulnerability of flat plate column joint with out slab shear reinforc...
eSAT Journals
 
Bond graphs and genetic algorithms for design and optimization of active dyna...
Bond graphs and genetic algorithms for design and optimization of active dyna...Bond graphs and genetic algorithms for design and optimization of active dyna...
Bond graphs and genetic algorithms for design and optimization of active dyna...
eSAT Journals
 
Dd3210971099
Dd3210971099Dd3210971099
Dd3210971099
IJMER
 
Dl3211461149
Dl3211461149Dl3211461149
Dl3211461149
IJMER
 
Design and manufacture of an angle adjustable crutch with kennedy key mechanism
Design and manufacture of an angle adjustable crutch with kennedy key mechanismDesign and manufacture of an angle adjustable crutch with kennedy key mechanism
Design and manufacture of an angle adjustable crutch with kennedy key mechanism
eSAT Journals
 

What's hot (18)

Design evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobileDesign evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobile
 
Seismic vulnerability of flat plate column joint with out slab shear reinforc...
Seismic vulnerability of flat plate column joint with out slab shear reinforc...Seismic vulnerability of flat plate column joint with out slab shear reinforc...
Seismic vulnerability of flat plate column joint with out slab shear reinforc...
 
Bond graphs and genetic algorithms for design and
Bond graphs and genetic algorithms for design andBond graphs and genetic algorithms for design and
Bond graphs and genetic algorithms for design and
 
Seismic response of _reinforced_concrete_concentrically_a_braced_frames
Seismic  response  of _reinforced_concrete_concentrically_a_braced_framesSeismic  response  of _reinforced_concrete_concentrically_a_braced_frames
Seismic response of _reinforced_concrete_concentrically_a_braced_frames
 
Bond graphs and genetic algorithms for design and optimization of active dyna...
Bond graphs and genetic algorithms for design and optimization of active dyna...Bond graphs and genetic algorithms for design and optimization of active dyna...
Bond graphs and genetic algorithms for design and optimization of active dyna...
 
Ijmet 10 01_155
Ijmet 10 01_155Ijmet 10 01_155
Ijmet 10 01_155
 
Free vibrational analysis of curved beam with uniform rectangular cross section
Free vibrational analysis of curved beam with uniform rectangular cross sectionFree vibrational analysis of curved beam with uniform rectangular cross section
Free vibrational analysis of curved beam with uniform rectangular cross section
 
IRJET - An Investigation of Stresses Induced in Curved Beams using MATLAB...
IRJET -  	  An Investigation of Stresses Induced in Curved Beams using MATLAB...IRJET -  	  An Investigation of Stresses Induced in Curved Beams using MATLAB...
IRJET - An Investigation of Stresses Induced in Curved Beams using MATLAB...
 
Dd3210971099
Dd3210971099Dd3210971099
Dd3210971099
 
IRJET- Explicit Dynamic Analysis of Gear Tooth of a Synchromesh Manual Transm...
IRJET- Explicit Dynamic Analysis of Gear Tooth of a Synchromesh Manual Transm...IRJET- Explicit Dynamic Analysis of Gear Tooth of a Synchromesh Manual Transm...
IRJET- Explicit Dynamic Analysis of Gear Tooth of a Synchromesh Manual Transm...
 
Design and development of a component by reverse engineering
Design and development of a component by reverse engineeringDesign and development of a component by reverse engineering
Design and development of a component by reverse engineering
 
Effect of Irregular Distribution of Load on RC Frame Structures
Effect of Irregular Distribution of Load  on RC Frame StructuresEffect of Irregular Distribution of Load  on RC Frame Structures
Effect of Irregular Distribution of Load on RC Frame Structures
 
Dl3211461149
Dl3211461149Dl3211461149
Dl3211461149
 
Comparison of bracings and shear walls as seismic strengthening methods to bu...
Comparison of bracings and shear walls as seismic strengthening methods to bu...Comparison of bracings and shear walls as seismic strengthening methods to bu...
Comparison of bracings and shear walls as seismic strengthening methods to bu...
 
Design and manufacture of an angle adjustable crutch with kennedy key mechanism
Design and manufacture of an angle adjustable crutch with kennedy key mechanismDesign and manufacture of an angle adjustable crutch with kennedy key mechanism
Design and manufacture of an angle adjustable crutch with kennedy key mechanism
 
Static Analysis of Go-Kart Chassis by Analytical and Solid Works Simulation
Static Analysis of Go-Kart Chassis by Analytical and Solid Works SimulationStatic Analysis of Go-Kart Chassis by Analytical and Solid Works Simulation
Static Analysis of Go-Kart Chassis by Analytical and Solid Works Simulation
 
Evaluation of performance of intake tower dam for
Evaluation of performance of intake tower dam forEvaluation of performance of intake tower dam for
Evaluation of performance of intake tower dam for
 
Dynamic analysis and condition assessment of rc building by varying material ...
Dynamic analysis and condition assessment of rc building by varying material ...Dynamic analysis and condition assessment of rc building by varying material ...
Dynamic analysis and condition assessment of rc building by varying material ...
 

Similar to Comparative study of rc framed structures using spectra based pushover analysis

Assessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingsAssessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildings
eSAT Publishing House
 
Seismic performance of r c buildings on sloping grounds with different types ...
Seismic performance of r c buildings on sloping grounds with different types ...Seismic performance of r c buildings on sloping grounds with different types ...
Seismic performance of r c buildings on sloping grounds with different types ...
eSAT Journals
 
Comparison of symmetric and asymmetric steel diagrid structures by non linear...
Comparison of symmetric and asymmetric steel diagrid structures by non linear...Comparison of symmetric and asymmetric steel diagrid structures by non linear...
Comparison of symmetric and asymmetric steel diagrid structures by non linear...
eSAT Journals
 
PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...
PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...
PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...
AM Publications
 

Similar to Comparative study of rc framed structures using spectra based pushover analysis (20)

Seismic evelution of rc space frame with rectangular and equivalent square co...
Seismic evelution of rc space frame with rectangular and equivalent square co...Seismic evelution of rc space frame with rectangular and equivalent square co...
Seismic evelution of rc space frame with rectangular and equivalent square co...
 
Assessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingsAssessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildings
 
Performance based seismic analysis of rc building considering the effect of d...
Performance based seismic analysis of rc building considering the effect of d...Performance based seismic analysis of rc building considering the effect of d...
Performance based seismic analysis of rc building considering the effect of d...
 
Performance evaluation of a multi storey car parking structure under strength...
Performance evaluation of a multi storey car parking structure under strength...Performance evaluation of a multi storey car parking structure under strength...
Performance evaluation of a multi storey car parking structure under strength...
 
Non linear static pushover analysis of irregular space frame structure with a...
Non linear static pushover analysis of irregular space frame structure with a...Non linear static pushover analysis of irregular space frame structure with a...
Non linear static pushover analysis of irregular space frame structure with a...
 
Effect of concentric and eccentric type of bracings on performance based seis...
Effect of concentric and eccentric type of bracings on performance based seis...Effect of concentric and eccentric type of bracings on performance based seis...
Effect of concentric and eccentric type of bracings on performance based seis...
 
IRJET- Seismic Time History Performance of Conventional Multi-Outriggers with...
IRJET- Seismic Time History Performance of Conventional Multi-Outriggers with...IRJET- Seismic Time History Performance of Conventional Multi-Outriggers with...
IRJET- Seismic Time History Performance of Conventional Multi-Outriggers with...
 
Seismic performance of r c buildings on sloping grounds with different types ...
Seismic performance of r c buildings on sloping grounds with different types ...Seismic performance of r c buildings on sloping grounds with different types ...
Seismic performance of r c buildings on sloping grounds with different types ...
 
Usage of N2 Method for the Performance Evaluation of Plan Asymmetric Structures
Usage of N2 Method for the Performance Evaluation of Plan Asymmetric StructuresUsage of N2 Method for the Performance Evaluation of Plan Asymmetric Structures
Usage of N2 Method for the Performance Evaluation of Plan Asymmetric Structures
 
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
 
Comparison of symmetric and asymmetric steel diagrid structures by non linear...
Comparison of symmetric and asymmetric steel diagrid structures by non linear...Comparison of symmetric and asymmetric steel diagrid structures by non linear...
Comparison of symmetric and asymmetric steel diagrid structures by non linear...
 
Optimization of a multistorey building by optimum
Optimization of a multistorey building by optimumOptimization of a multistorey building by optimum
Optimization of a multistorey building by optimum
 
Experimental investigation on circular hollow steel columns in filled with li...
Experimental investigation on circular hollow steel columns in filled with li...Experimental investigation on circular hollow steel columns in filled with li...
Experimental investigation on circular hollow steel columns in filled with li...
 
Experimental investigation on circular hollow steel columns in filled with li...
Experimental investigation on circular hollow steel columns in filled with li...Experimental investigation on circular hollow steel columns in filled with li...
Experimental investigation on circular hollow steel columns in filled with li...
 
Experimental investigation on circular hollow steel
Experimental investigation on circular hollow steelExperimental investigation on circular hollow steel
Experimental investigation on circular hollow steel
 
PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...
PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...
PROGRESSIVE COLLAPSE ANALYSIS OF REINFORCED CONCRETE SYMMETRICAL AND UNSYMMET...
 
Analysis of super structure building with plan and elevation irregularities u...
Analysis of super structure building with plan and elevation irregularities u...Analysis of super structure building with plan and elevation irregularities u...
Analysis of super structure building with plan and elevation irregularities u...
 
Analytical assessment on progressive collapse potential of new reinforced con...
Analytical assessment on progressive collapse potential of new reinforced con...Analytical assessment on progressive collapse potential of new reinforced con...
Analytical assessment on progressive collapse potential of new reinforced con...
 
Progressive collapse analysis of an rc structure subjected to seismic loads i...
Progressive collapse analysis of an rc structure subjected to seismic loads i...Progressive collapse analysis of an rc structure subjected to seismic loads i...
Progressive collapse analysis of an rc structure subjected to seismic loads i...
 
Effect of steel bracing on vertically irregular r.c.c building frames under s...
Effect of steel bracing on vertically irregular r.c.c building frames under s...Effect of steel bracing on vertically irregular r.c.c building frames under s...
Effect of steel bracing on vertically irregular r.c.c building frames under s...
 

More from eSAT Journals

Material management in construction – a case study
Material management in construction – a case studyMaterial management in construction – a case study
Material management in construction – a case study
eSAT Journals
 
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materialsLaboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
eSAT Journals
 
Geographical information system (gis) for water resources management
Geographical information system (gis) for water resources managementGeographical information system (gis) for water resources management
Geographical information system (gis) for water resources management
eSAT Journals
 
Estimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn methodEstimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn method
eSAT Journals
 
Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...
eSAT Journals
 

More from eSAT Journals (20)

Mechanical properties of hybrid fiber reinforced concrete for pavements
Mechanical properties of hybrid fiber reinforced concrete for pavementsMechanical properties of hybrid fiber reinforced concrete for pavements
Mechanical properties of hybrid fiber reinforced concrete for pavements
 
Material management in construction – a case study
Material management in construction – a case studyMaterial management in construction – a case study
Material management in construction – a case study
 
Managing drought short term strategies in semi arid regions a case study
Managing drought    short term strategies in semi arid regions  a case studyManaging drought    short term strategies in semi arid regions  a case study
Managing drought short term strategies in semi arid regions a case study
 
Life cycle cost analysis of overlay for an urban road in bangalore
Life cycle cost analysis of overlay for an urban road in bangaloreLife cycle cost analysis of overlay for an urban road in bangalore
Life cycle cost analysis of overlay for an urban road in bangalore
 
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materialsLaboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
 
Laboratory investigation of expansive soil stabilized with natural inorganic ...
Laboratory investigation of expansive soil stabilized with natural inorganic ...Laboratory investigation of expansive soil stabilized with natural inorganic ...
Laboratory investigation of expansive soil stabilized with natural inorganic ...
 
Influence of reinforcement on the behavior of hollow concrete block masonry p...
Influence of reinforcement on the behavior of hollow concrete block masonry p...Influence of reinforcement on the behavior of hollow concrete block masonry p...
Influence of reinforcement on the behavior of hollow concrete block masonry p...
 
Influence of compaction energy on soil stabilized with chemical stabilizer
Influence of compaction energy on soil stabilized with chemical stabilizerInfluence of compaction energy on soil stabilized with chemical stabilizer
Influence of compaction energy on soil stabilized with chemical stabilizer
 
Geographical information system (gis) for water resources management
Geographical information system (gis) for water resources managementGeographical information system (gis) for water resources management
Geographical information system (gis) for water resources management
 
Forest type mapping of bidar forest division, karnataka using geoinformatics ...
Forest type mapping of bidar forest division, karnataka using geoinformatics ...Forest type mapping of bidar forest division, karnataka using geoinformatics ...
Forest type mapping of bidar forest division, karnataka using geoinformatics ...
 
Factors influencing compressive strength of geopolymer concrete
Factors influencing compressive strength of geopolymer concreteFactors influencing compressive strength of geopolymer concrete
Factors influencing compressive strength of geopolymer concrete
 
Experimental behavior of circular hsscfrc filled steel tubular columns under ...
Experimental behavior of circular hsscfrc filled steel tubular columns under ...Experimental behavior of circular hsscfrc filled steel tubular columns under ...
Experimental behavior of circular hsscfrc filled steel tubular columns under ...
 
Evaluation of punching shear in flat slabs
Evaluation of punching shear in flat slabsEvaluation of punching shear in flat slabs
Evaluation of punching shear in flat slabs
 
Evaluation of performance of intake tower dam for recent earthquake in india
Evaluation of performance of intake tower dam for recent earthquake in indiaEvaluation of performance of intake tower dam for recent earthquake in india
Evaluation of performance of intake tower dam for recent earthquake in india
 
Evaluation of operational efficiency of urban road network using travel time ...
Evaluation of operational efficiency of urban road network using travel time ...Evaluation of operational efficiency of urban road network using travel time ...
Evaluation of operational efficiency of urban road network using travel time ...
 
Estimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn methodEstimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn method
 
Estimation of morphometric parameters and runoff using rs & gis techniques
Estimation of morphometric parameters and runoff using rs & gis techniquesEstimation of morphometric parameters and runoff using rs & gis techniques
Estimation of morphometric parameters and runoff using rs & gis techniques
 
Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...
 
Effect of use of recycled materials on indirect tensile strength of asphalt c...
Effect of use of recycled materials on indirect tensile strength of asphalt c...Effect of use of recycled materials on indirect tensile strength of asphalt c...
Effect of use of recycled materials on indirect tensile strength of asphalt c...
 
Effect of skew angle on static behaviour of reinforced concrete slab bridge d...
Effect of skew angle on static behaviour of reinforced concrete slab bridge d...Effect of skew angle on static behaviour of reinforced concrete slab bridge d...
Effect of skew angle on static behaviour of reinforced concrete slab bridge d...
 

Recently uploaded

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
rknatarajan
 

Recently uploaded (20)

The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 

Comparative study of rc framed structures using spectra based pushover analysis

  • 1. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 101 COMPARATIVE STUDY OF RC FRAMED STRUCTURES USING SPECTRA BASED PUSHOVER ANALYSIS Pavan Kumar N1 , Avinash Gornale2 , Gargi G S3 , B G Naresh Kumar4 1 PG Student, Dept. of Civil Engineering, BGS Institute of Technology, Mandya District, Karnataka, India 2 Asst. Professor, Dept. of Civil Engineering, Maharaja Institute of Technology, Mysore District, Karnataka, India 3 Asst. Professor, Dept. of Civil Engineering, BGS Institute of Technology, Mandya District, Karnataka, India 4 Prof & Principal, Dept. of Civil Engineering, Maharaja Institute of Technology, Mysore District, Karnataka, India Abstract Spectra based multimodal adaptive pushover analysis considers higher modes of vibration and combines them using SRSS rule and scale factors. Damage index for the structures are calculated to evaluate the degree of damage occurred after a seismic event. For the present study the Spectra based multimodal adaptive pushover analysis is adopted for G+ 4 storeys Symmetric and G+ 4 storeys Asymmetric Reinforced concrete framed structures. The Expended Energy based damage index methods are used to calculate Damage Index for symmetric and asymmetric structures. ETABS 2015 software is utilized for modeling and analysis of Reinforced concrete framed structures. The comparative studies are carried out between the structure considering only 1st mode and considering all modes and compared between 3 methods of damage index. It is observed that the capacity obtained by considering all modes is less than the capacity obtained by considering only 1st mode. The target displacement obtained considering only 1st mode is less than the target displacement obtained considering all modes. And the damage index obtained by considering all modes is more than the damage index obtained by considering only 1st mode. Therefore it is necessary to consider all modes to get accurate results. In asymmetric building the ductility is less, the capacity is less, demand is high, and degree of damage is more when compared with symmetric building. Keywords: pushover analysis, damage index, RC frame, multimodal, symmetric and asymmetric --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION The Spectra based multimodal adaptive pushover analysis which is proposed by K. Shakeri, M. Mohebbi Asbmarz and M.A. Shayanfar 2008[3] is adopted for G+4 storey Symmetric and G+4 storey Asymmetric building in the analysis of Reinforced concrete framed structures. The Expended Energy based damage index methods which is proposed by Anthugari Vimala, Pradeep Kumar, Ramancharla (2014) [10] are used to calculate Damage Index for symmetric and asymmetric structures. ETABS 2015 software is utilized for modelling and analysis of Reinforced concrete framed structures. Spectra based multimodal adaptive pushover analysis considers higher modes of vibration and combines them using SRSS rule and scale factors. All these factors are very essential to increase the accuracy of the results. Damage index for the structures are calculated to evaluate the degree of damage occurred after a seismic event. The Expended energy based damage index is represented as ratio of inelastic energy dissipated at any displacement to the total inelastic energy capacity of the structure. The energy method is used to calculate Global damage index of the structure. This project work focuses on Evaluation and Comparative study of damage index of symmetric and asymmetric RC framed structures using Spectra based multimodal adaptive pushover analysis. In our present study we have adopted two example reinforced concrete framed structures (i) 5 storey symmetric structure and (ii) 5 storey asymmetric structure. Spectra based multimodal adaptive pushover analysis used as RC framed analysis. ETABS 2015 is utilized for modelling and analysis. Damage indices are calculated and compared with symmetrical and asymmetrical structures. 2. MODELS CONSIDERED FOR STUDY 2.1 Symmetric Model A G+4 storey, 7-bay by 2-bay symmetrical reinforced concrete framed residential building is considered. Dimension of Column 0.23 X 0.4 m Dimension of Beam 0.23 X 0.35 m Thickness of slab 0.125 m Thickness of wall 0.23 m Soil type II Live load 2 KN/m Location of building Mysore, Karnataka, India.
  • 2. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 102 Fig 1 Plan of Symmetric Building Fig 2 3D View of Symmetric Building 2.2 Asymmetric Model An Asymmetrical residential building is as shown in figure below. Dimension of column 0.23 X 0.4 m, Beam 0.23 X 0.35m Thickness of slab 0.125 m Thickness of wall 0.23 m Soil type II Live load 2 KN/m Location of Building Mysore, Karnataka, India. Fig 3 Plan of Asymmetric Building Fig 4 3D View of Asymmetric Building 3. SUMMARY OF ANALLYSIS IN ETABS 2015 1. Create the model with nonlinear properties. 2. Set the maximum number of modes as the number of stories multiplied by 3 for 3D Analysis. 3. Perform gravity analysis and modal analysis. From modal analysis result the direction of modes (weather X-direction or Y-direction) are obtained. 4. In case of asymmetric structures it is needed to calculate the eccentricity ratio in each storey and apply it to lateral load pattern. 5. Define the nonlinear load case for each mode separately in X or Y direction according to the direction of mode.
  • 3. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 103 6. Perform pushover analysis and note down the maximum base shear in each mode and combine them by SRSS rule. 7. Calculate scale factor for each mode and apply them to nonlinear load cases in each mode. 8. Again perform pushover analysis, resulting base shears are combined by SRSS rule and scale factors are calculated. 9. Apply these scale factors to a separate nonlinear load case which contain all the mode in X and Y direction with above computed scale factor and perform pushover analysis. 10. From bilinear pushover curve we can obtain target displacement. Compare target and monitored displacement with applied displacement in the nonlinear load case, if target displacement is more than applied load case then apply target displacement as applied load and perform the final pushover analysis. 11. Calculate damage index for the structure from the pushover curve results using, 𝐷1 = 𝐸 − 𝐸𝑖𝑒 𝐸 𝑇 − 𝐸𝑖𝑒 × 100 𝐷2 = 𝐸 − 𝐸𝑒 𝐸 𝑇 − 𝐸𝑖𝑒 × 100 𝐷3 = 𝐸𝐿 − 𝐸 𝑁𝐿 𝐸𝐿𝑇 − 𝐸 𝑁𝐿𝑇 × 100 Where, 𝐷1 , 𝐷2 𝑎𝑛𝑑𝐷3 Are Damage index for method 1, method 2 and method 3 respectively. E = Energy dissipated at which damage is being estimated, 𝐸𝑖𝑒 = Initial yield energy of structure; 𝐸 𝑇 = Total energy absorbed by structure; 𝐸𝑒 = Instantaneous elastic energy at which damage is being estimated 𝐸𝐿= Linear energy at displacement level at which damage is being estimated; 𝐸 𝑁𝐿 = Nonlinear energy at which damage is being estimated; 𝐸𝐿𝑇= Linear energy at maximum displacement of structure; 𝐸 𝑁𝐿𝑇 = Nonlinear energy at maximum displacement of structure 4. RESULTS AND DISCUSSIONS 4.1 Pushover Curve Results The 1st mode reaches ultimate yielding point at 181.7 mm, 1216.5638 KN whereas final combined load case reach ultimate yielding point at 105.3 mm, 98.4257 KN. Here it can be observed that by considering all the modes, the capacity of the structure is decreased by 43% when compared with only one mode. Hence adopting spectra based adaptive multimode analysis is very useful in getting accuracy of the results which include all the modes. Ductility of symmetric building is more when compared to asymmetric structure. Symmetric structure shows post yielding behavior and also strength degradation behavior. Asymmetric structure is showing post yielding behavior but there is no strength degradation behavior this shows that asymmetric structure is undergoing brittle failure of structural members. Fig 5 Pushover Curve For Symmetrical Structure At Mode- 1 In X-Direction Fig 6 Pushover Curve For Symmetrical Structure By Combining All Modes In X-Direction
  • 4. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 104 Fig 7 Pushover Curve For Asymmetrical Structure At Mode-1 In Y-Direction Fig 8 Pushover Curve For Asymmetrical Structure With Combined Loading In Y-Direction 4.2 𝐒 𝐚 𝐯𝐬 𝐒 𝐝 Curve Results Fig 9 Sa vs Sd Curve For Symmetric Structure At Mode-1 In X-Direction Fig 10 Sa vs Sd Curve For Symmetric Structure For Combined Load Case In X-Direction Fig 11 Sa vs Sd Curve For Asymmetric Structre At Mode-1 In Y-Direction Fig 12 Sa vs Sd Curve For Asymmetric Structure For Combined Load Case In Y-Direction
  • 5. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 105 In symmetric structure the performance point is found only in mode-1. The displacement at performance point in mode- 1 is 340.8 mm. and in all modes the displacement at performance point 565.9 mm which means participation of mode-1 in the analysis is more than any other modes. But other 40% cannot be neglected, thus we need to consider all the modes for combined effect. In asymmetric structure the performance point is found only in mode-4. The maximum displacement occurred in mode-4 is 34.3 mm. In final result also there is no meet of point observed. Therefore it is very much necessary to adopt spectra based adaptive multimodal pushover procedure to know the changes in behavior of structure at different modes. Hence this method help to choose peak performance results for the design of structure. From the above results the capacity of the symmetric structure is greater when compared with asymmetric structure. 4.3 Bilinear Curve Results Target displacements obtained are used in the design of structure. In symmetric model first mode represents the target displacement of 378.3mm whereas all modes combined final target displacement is 523.4mm. Here it can be observed that 27% less target displacement is obtained when considering only 1st mode. Therefore considering all the mode is important to get accurate results and good design. In symmetric model the target displacement is within the capacity of the structure whereas in asymmetric model the target displacement is beyond the capacity of the structure. Fig 13 Bilinear Pushover Curve For Symmetric Structure At Mode-1 In X-Direction Fig 14 Bilinear Pushover Curve For Symmetric Structure For Combined Load Case In X-Direction Fig 15 Bilinear Pushover Curve For Asymmetric Structure At Mode-1 In Y-Direction Fig 16 Bilinear Pushover Curve For Asymmetric Structure For Combined Load Case In Y-Direction
  • 6. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 106 4.4 Hinge State Results Table 1 Performance Level PERFORMANCE LEVEL DESCRIPTION Operational Level (OL) Building will be under construction. Minor repairs may be required. Immediate occupancy level (IO) Building will be available to accommodate. Life safety level (LS) Very low chances of collapse of structural members. No harm to life occurs. Collapse prevention level (CP) This requires stability under vertical loads. Fig 17 Hinge State For Symmetrical Structure At Mode-1 in X-Direction Fig 18 Hinge State For Symmetrical Structure For Combined Load Case In X-Direction Fig 19 Hinge State For Asymmetrical Structure At Mode-1 In Y-Direction
  • 7. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 107 Fig 20 Hinge State For Asymmetrical Structure For Combined Load Case In Y-Direction In symmetrical structure, the first mode contain total of 1165 hinges of which 1075 hinges are in immediate occupancy level, 42 hinges are in life safety level, 0 in collapse prevention level and 48 are beyond collapse prevention level. When all modes combined case results contain total of 1165 hinges of which 1081 hinges are in immediate occupancy level, 36 hinges are in life safety level, 0 in collapse prevention level and 48 are beyond collapse prevention level. Thus in spectra based adaptive multimodal analysis, the behavior of the structure in every single step of analysis can be observed. The failure of hinges occurs first where the columns are placed closely. Therefore columns should be placed at equal distances as far as possible. The failure of hinges starts at bottom storey and gradually transfers to upper stories with each mode. 4.5 Damage Index Results Table 2 Ranges Of Damage Index (Dorde Ladinovic, Aleksandra Radujkovic, Andrija Raseta (2011) [16]) Degree of damage Damage index State of structure Minor 0.0-0.2 Serviceable Moderate 0.2-0.5 Repairable Severe 0.5-1.0 Irreparable Collapse >1.0 Loss of building Table 3 Damage Index For Symmetric Structure DAMAGE INDEX FOR SYMMETRICAL STRUCTURE Mode no. METHOD 1 METHOD 2 METHOD 3 PX1 0.230776 0.166491 0.023737 PX4 0.162262 0.131261 0.016884 PX7 1 0.004032 1 PX10 0.14566 0.135823 0.013773 PX11 0.947425 0.23723 2.468422 PY2 0.966751 0.732177 1.072819 PY5 1 0.269953 1 PY8 1 0.185354 0.28759 PY13 1 0.819354 1 PY14 0.809682 0.33357 2.834754 OVERALL DAMAGE INDEX IN X-DIRECTION 0.1362 0.09985 0.01345 OVERALL DAMAGE INDEX IN Y-DIRECTION 0.6663 0.1907 0.5262 Table 4 Damage Index For Asymmetric Structure DAMAGE INDEX FOR ASYMMETRICAL STRUCTURE Mode no. METH OD 1 METHOD 2 METHOD 3 PX3 0.3490 08 0.347986 2.274995 PX6 1 0.680699 1 PX10 1 0.124079 1 PX13 1 0.516721 1 PX15 0.9322 06 0.580708 0.76984 PY1 1 0.601102 1 PY4 1 0.677741 1 PY7 1 N/A 1 PY9 0.5712 56 0.432167 1.42617 PY11 0.8492 1 0.745895 1.086192 OVERALL DAMAGE INDEX IN X-DIRECTION 1 0.52 1 OVERALL DAMAGE INDEX IN Y-DIRECTION 1 0.628 1
  • 8. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 108 The higher value of damage index is observed in all modes combined case when compared with the damage index by considering only 1st mode. Therefore to get accurate results, all the modes need to be considered. The severe and collapsed state is observed more in asymmetric model than symmetric model. Therefore as the asymmetry increases the damage also increase. Out of three methods, the Method 1 and Method 3 is indicating little higher degree of damage when compared with Method 2. 5. CONCLUSION From the pushover curve results it is observed that the capacity of the structure obtained by considering all modes is less than the capacity obtained by considering only 1st mode. Hence adopting spectra based adaptive multimode analysis is very useful in getting more accurate results. By adopting asymmetric structure over symmetric structure the ductility of structure may be compromised. Hence suitable precautionary measures should be taken while adopting asymmetric structures. In symmetric model the capacity is meeting the demand of the building where as in asymmetric model the demand is very high. Thus we can conclude that, as the asymmetry of structure increases the capacity of the structure decreases. From bilinear curve results it is observe that target displacement obtained considering only 1st mode is less than the target displacement obtained considering all modes. Therefore considering all the modes is important to get accurate results and good design. More number of hinges reach failure in asymmetric model when compared with symmetric model. Failure occurs early where columns are placed closely. Therefore columns should be placed at equal interval as far as possible. The higher value of damage index is obtained by considering all modes when compared with considering only 1st mode. Therefore to get accurate results we need to consider all the modes. The severe and collapsed state of damage is observed more in asymmetric model than in symmetric model. Therefore as the asymmetry increases the damage also increase. Out of three methods of damage index, the Method 1 and Method 3 is indicating little higher degree of damage when compared with Method 2. REFERENCES [1] IS 1893 (Part 1): 2002, Criteria for earthquake resistant design of structures. Bureau of Indian Standard, Manak Bhavan, New Delhi, India. [2] Rahul Rana, Limin Jin, and Atila Zekioglu (2004). Pushover analysis of a 19 storey concrete shear wall building. 13th world conference on earthquake engineering, Vancouver B.C Canada. [3] K. Shakeri, M.A. Shayanfar and M. Mohebbi Asbmarz (2008). A SPECTRA-BASED MULTI MODAL ADAPTIVE PUSHOVER PROCEDURE FOR SEISMIC ASSESSMENT OF BUILDINGS. The 14th World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China. [4] Yousuf Dinar, Md. Imam Hossain, Rajib Kumar Biswas, Md. Masud Rana. Descriptive study of pushover analysis in RCC structures of rigid joint. IOSR Journal of Mechanical and Civil Engineering (IOSR JMCE) ISSN: 2278-1684 Volume 11, Issue 1 (January-February), PP 60-68. [5] J.R. Qian, W.J. Zhang, and X.D. Ji (2008). Application of pushover analysis on earthquake response predication of complex large-span steel structures. The 14th World Conference on Earthquake Engineering October 12-17, 2008, Beijing, China. [6] Philip DE GUZMAN1 and Yuji ISHIYAMA (2004). Collapse assessment of building structures using damage index. 13th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 0734. [7] Tathagata Roy and Dr. Pankaj Agarwal (2014). Damage Index of Reinforced Concrete Structures in India. International Journal of Research (IJR) Vol-1, Issue-5, June 2014. [8] Saurabh Shiradhonkar and Ravi Sinha (2012). Detailed evaluation of available seismic damage indices. A project report, IITR. [9] Sumit R. Thakur, Sudhir P.Patil, Dr.Keshav K.Sanagle. Evaluation of damage index of high rise building using nonlinear static seismic analysis. International Journal of Emerging Technology and Advanced Engineering Volume 2, Issue 10, October 2012. [10] ANTHUGARI VIMALA and PRADEEP KUMAR RAMANCHARLA (2014). Expended energy based damage assessment of RC bare frame using nonlinear pushover analysis. Urban Safety of Mega Cities in Asia 2014 (USMCA 2014). [11] Chopra, A.K. and Goel, R.K. (2002). A modal pushover analysis procedure for estimating seismic demands for buildings. Earthquake Engineering and Structural Dynamics, 31, 561-582. [12] Aydinoglu M.N. (2003). An incremental response spectrum analysis procedure based on inelastic spectral displacements for multi-mode seismic performance evaluation. Bulletin of Earthquake Engineering, 1, 3- 36. [13] Kalkan, E. and Kunnath S.K. (2006). Adaptive modal combination procedure for nonlinear static analysis of building structures. Journal of Structural Engineering, ASCE, 132:11, 1721-1731. [14] R. Sinha & S. R. Shiradhonkar. Seismic Damage Index for Classification of Structural Damage – Closing the Loop. 15th World Conference on Earthquake Engineering, Lisboa 2012.
  • 9. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 07 | July-2015, Available @ http://www.ijret.org 109 [15] Young J. Park, Anderi M. Reiniorn, and Shashi K. Kunnath. Seismic damage analysis of reinforced concrete buildings. 9th World Conference on Earthquake Engineering, August 2-9, 1988, Tokyo- Kyoto, Japan (Vol. VII). [16] Dorde Ladinovic, Aleksandra Radujkovic, Andrija Raseta. Seismic performance assessment based on damage of structures – part 1: theory. FACTA UNIVERSITATIS Series: Architecture and Civil Engineering Vol. 9, No 1, 2011, pp. 77 – 88 BIOGRAPHIES Mr. Pavan Kumar N, is a Final Year PG Student, pursuing his Master of Technology in Structural Engineering from BGS Institute of Technology, Mandya District, Karnataka, India. Mr. Avinash Gornale BE, M.Tech is working as an Assistant Professor in department of civil engineering in Maharaja Institute of Technology, Mysore, Karnataka. His areas of research interest include Earthquake engineering and Performance Evaluation. Ms. Gargi G S BE, M.Tech is working as an Assistant Professor in department of civil engineering in BGS Institute of Technology, Mandya District, Karnataka, India. BE and M.Tech in CAD Structures from PES, Mandya. Dr. B G Naresh Kumar B.E., M.E., Ph.D. working as Principal in Maharaja Institute of Technology, Mysore, Karnataka. ME & Ph.D. from IIT Kharagpur. In the past he worked as Legal Advisor for AICTE, New Delhi.