1. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. REDEMPTO P. MADRAZO
PROFESSIONAL ELECTRICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale 1:250 m
GRND FLR. POWER LAYOUT PLAN
1
Scale 1:250 m
2ND FLR. POWER LAYOUT PLAN
2
Scale 1:250 m
3RD FLR. POWER LAYOUT PLAN
3
E1
25 of 30
2. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. REDEMPTO P. MADRAZO
PROFESSIONAL ELECTRICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale 1:250 m
ROOFDECK POWER LAYOUT PLAN
1
Scale 1:250 m
GRND FLR. LIGHTING LAYOUT PLAN
2
Scale 1:250 m
2ND FLR. LIGHTING LAYOUT PLAN
3
E2
26 of 30
3. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. REDEMPTO P. MADRAZO
PROFESSIONAL ELECTRICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale 1:250 m
3RD FLR. LIGHTING LAYOUT PLAN
1
Scale 1:250 m
ROOFDECK LIGHTING LAYOUT PLAN
2
Scale 1:250 m
GRND FLR. INTERCOM LAYOUT PLAN
3
E3
27 of 30
4. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. REDEMPTO P. MADRAZO
PROFESSIONAL ELECTRICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Not Drawn To Scale
RISER DIAGRAM
6
Not Drawn To Scale
GROUNDING PLAN
4
Not Drawn To Scale
LIGHTING ARRESTER PLAN
5
Scale 1:250 m
2ND FLR. INTERCOM LAYOUT PLAN
1
Scale 1:250 m
3RD FLR. INTERCOM LAYOUT PLAN
2
Scale 1:250 m
ROOFDECK INTERCOM LAYOUT PLAN
3
E4
28 of 30
5. Not Drawn To Scale
SINGLE LINE DIAGRAM
2
Not Drawn To Scale
TELEPHONE SYS. RISER DIAGRAM
2 Not Drawn To Scale
INTERCOM SYSTEM RISER DIAGRAM
3
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. REDEMPTO P. MADRAZO
PROFESSIONAL ELECTRICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale 1:250 m
GRND FLR. ACU OUTLET LAYOUT PLAN
3
Scale 1:250 m
2ND FLR. ACU OUTLET LAYOUT PLAN
3
Scale 1:250 m
3RD FLR. ACU OUTLET LAYOUT PLAN
3
E5
29 of 30
6. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. REDEMPTO P. MADRAZO
PROFESSIONAL ELECTRICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Not Drawn To Scale
CABLE TRAY LADDER DETAIL
2
Not Drawn to Scale
LOCATION PLAN
3
this Site
Scale 1:250 m
TYPICAL CABLE TRAY LADDER LAYOUT
1
E6
30 of 30