1. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
A1
1 of 30
Not Drawn to Scale
LOCATION PLAN
3
this Site
Not Drawn to Scale
VICINITY MAP
3
this Site
BUILDING OFFICIAL
LAND USE AND ZONING
LINE AND GRADE
ARCHITECTURAL
STRUCTURAL
SANITARY
ELECTRICAL
MECHANICAL
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC
WORKS AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL CITY OF ILIGAN
FIRE SAFETY
A1
1. PERSPECTIVE VIEW
2. VICINITY MAP
3. LOCATION PLAN
A2
1. GROUND FLOOR PLAN
2. SECOND FLOOR PLAN
3. THIRD FLOOR PLAN
4. LEFT ELEVATION
5. RIGHT ELEVATION'
A3
1. ROOFDECK FLOOR PLAN
2. FRONT ELEVATION
3. REAR ELEVATION
4. SECTION THRU - C
5. SECTION THRU - D
6. SECTION THRU - L
A4
1. SECTION THRU - A
2. SECTION THRU - B
3. GRND FLR REFLECTED CEILING PLAN
4. SECTION THRU - E
5. SECTION THRU - F
A5
1. 2ND FLR REFLECTED CEILING PLAN
2. 3RD FLR REFLECTED CEILING PLAN
3. RFDCK REFLECTED CEILING PLAN
4. CEILING FRAME DETAIL
5. DRY WALL FRAME DETAIL
A6
1. GLASS PARTITION DETAIL
2. SCHEDULE OF WINDOWS
A7
1. SCHEDULE OF DOORS
2. POLYCARBONATE ENCLOSURE DETAIL
3. POLYCARBONATE CANOPY DET.
4. POLYCARBONATE CANOPY FRAMING DET.
S1
1. FOUNDATION PLAN
2. SECOND FLOOR FRAMING PLAN
3. THIRD FLOOR FRAMING PLAN
4. COMBINED FOOTING 1 (CF-1) DETAIL
3. COMBINED FOOTING 4 (CF-4) DETAIL
S2
1. ROOFDECK FRAING PLAN
2. ROOF BEAM PLAN
3. ROOF FRAMING PLAN
4. COMBINED FOOTING 2 (CF-2) DETAIL
5. COMBINED FOOTING 3 (CF-3) DETAIL
S3
1. COMBINED FOOTING 5 (CF-5) DETAIL
2. WALL FOOTING DETAIL
3. COLUMN DETAIL
4. TIE BEAM TRANSVERSE STRUCTURE PROFILE
5. TIE BEAM DETAIL
S4
1. SCHEDULE OF BEAMS - 1
S5
1. SCHEDULE OF BEAMS - 2
S6
1. SECOND FLOOR SLAB DETAIL
2. CONCRETE CANOPY DETAIL
3. CONCRETE GUTTER DETAIL
S7
1. MAIN STAIR SECTION
2. MAIN STAIR DETAIL
3. MAIN STAIR PLAN
4. MAIN STAIR PROFILE
5. SIDE STAIR PROFILE
6. SIDE STAIR LANDING SECTION
7. SIDE STAIR LANDING PLAN
8. SIDE STAIR DETAIL
9. TYPICAL STEEL HAN DRAIL DETAIL
S8
1. ELEVATOR SHAFT FOOTING PLAN
2. ELEVATOR SHAFT FOOTING SECTION
3. ELEVATOR SHAFT WALL DETAIL
4. ELEVATOR SHAFT LAYOUT PLAN
5. ELEVATOR SHAFT ROOF DETAIL
6. PLANTED COLUMN DETAIL
7. FOLDED SLAB DETAIL
S9
1. STEEL STAIR DETAIL
2. WATER TANK PLATFORM DETAIL
3. STEEL TRUSS 1 (T-1) DETAIL
4. STEEL TRUSS 2 (T-2) DETAIL
5. STEEL TRUSS 3 (T-3) DETAIL
6. STEEL TRUSS 4 (T-4) DETAIL
P1
1. GRND FLR DRAINAGE SYSTEM LAYOUT PLAN
2. 2ND FLR DRAINAGE SYSTEM LAYOUT PLAN
3. 3RD FLR DRAINAGE SYSTEM LAYOUT PLAN
4. RIGHT WING PIPING ISOMETRIC DIAGRAM
P2
1. ROOFDECK DRAINAGE SYSTEM LAYOUT PLAN
2. GRND FLR WATER SUPPLY LAYOUT PLAN
3. 2ND FLR WATER SUPPLY LAYOUT PLAN
4. LEFT WING PIPING ISOMETRIC DIAGRAM
P3
1. 3RD FLR WATER SUPPLY LAYOUT PLAN
2. ROOFDECK WATER SUPPLY LAYOUT PLAN
3. GRND FLR STORM DRAINAGE LAYOUT PLAN
4. DIRECTOR'S OFFICE PUMBING LAYOUT PLAN
5. FACULTY LOUNGE PLUMBING LAYOUT PLAN
P4
1. BLOWN UP PLUMBING LAYOUT PLAN
P5
1. CISTERN DETAIL
2. SEPTIC VAULT DETAIL
3. LOCATION PLAN
M1
1. GRND FLR FIRE ALARM SYSTEM LAYOUT PLAN
2. 2ND FLR FIRE ALARM SYSTEM LAYOUT PLAN
3. 3RD FLR FIRE ALARM SYSTEM LAYOUT PLAN
4. FIRE ALARM SYSTEM RISER DIAGRAM
5. FIRE ALARM SYSTEM ELEMENTARY DIAGRAM
M2
1. RFDCK FIRE ALARM SYSTEM LAYOUT PLAN
2. ELEVATOR HOISTWAY PIT PLAN
3. ELEVATOR HOISTWAY LANDING PLAN
4. ELEVATOR HOISTWAY OVERHEAD PLAN
5. ELEVATOR HOISTWAY SECTION
E1
1. GRND FLR POWER CIRCUIT LAYOUT PLAN
2. 2ND FLR POWER CIRCUIT LAYOUT PLAN
3. 3RD FLR POWER CIRCUIT LAYOUT PLAN
E2
1. RFDCK POWER CIRCUIT LAYOUT PLAN
2. GRND FLR LIGHTING CIRCUIT LAYOUT PLAN
3. 2ND FLR LIGHTING CIRCUIT LAYOUT PLAN
4. SCHEDULE OF POWER & LIGHTING LOADS
E3
1. 3RD FLR LIGHTING CIRCUIT LAYOUT PLAN
2. RFDCK LIGHTING CIRCUIT LAYOUT PLAN
3. GRND FLR INTERCOM LINE LAYOUT PLAN
4. SCHEDULE OF ACU & SUBFEEDER LOADS
E4
1. 2ND FLR INTERCOM LINE LAYOUT PLAN
2. 3RD FLR INTERCOM LINE LAYOUT PLAN
3. RFDCK INTERCOM LINE LAYOUT PLAN
4. GROUNDING PLAN
5. LIGHTNING ARRESTER PLAN
6. ELECTRICAL RISER DIAGRAM
E5
1. GRND FLR ACU OUTLET LAYOUT PLAN
2. 2ND FLR ACU OUTLET LAYOUT PLAN
3. 3RD FLR ACU OUTLET LAYOUT PLAN
4. ELECTRICAL SINGLE LINE DIAGRAM
5. TELEPHONE LINE RISER DIAGRAM
6. INTERCOM LINE RISER DIAGRAM
E6
1. TYPICAL CABLE TRAY LADDER LAYOUT PLAN
2. CABLE TRAY LADDER DETAIL
3. LOCATION PLAN
2. Scale: 1:250 m
GROUND FLOOR PLAN
1
Scale: 1:250 m
SECOND FLOOR PLAN
2
Scale: 1:250 m
THIRD FLOOR PLAN
3
Scale: 1:100 m
LEFT ELEVATION
4
Scale: 1:100 m
RIGHT ELEVATION
5
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
A2
2 of 30
3. Scale: 1:250 m
FRONT ELEVATION
2
Scale: 1:250 m
REAR ELEVATION
3
Scale: 1:100 m
SECTION THRU - L
6
Scale: 1:100 m
SECTION THRU - C
4 Scale: 1:100 m
SECTION THRU - D
5
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:250 m
ROOFDECK FLOOR PLAN
1
A3
3 of 30
4. Scale: 1:250 m
SECTION THRU - A
1
Scale: 1:250 m
SECTION THRU - B
2
Scale: 1:100 m
SECTION THRU - E
4
Scale: 1:100 m
SECTION THRU - F
5
Scale: 1:250 m
GRND FLR REF CEILING PLAN
3
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
A4
4 of 30
5. CEILING FRAME ISOMETRIC VIEW
DRY WALL FRAME ISOMETRIC VIEW
Scale: 1:30 m
CEILING FRAME DETAIL
4
Scale: 1:30 m
DRY WALL FRAME DETAIL
5
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:250 m
2ND FLR. REF. CEILING PLAN
1
Scale: 1:250 m
3RD FLR. REF. CEILING PLAN
2
Scale: 1:250 m
RF.DCK. FLR. REF. CEILING PLAN
3
A5
5 of 30
6. CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:30 m
GLASS PARTITION DETAIL
1
Scale: 1:25 m
SCHEDULE OF WINDOWS
2
A6
6 of 30
7. Scale: 1:50 m
POLYCARBONATE ENCLOSURE DETAIL
2
AT 2ND FLR. SIDE STAIR PLAN AT 3RD FLR. SIDE STAIR PLAN AT RF DECK SIDE STAIR PLAN
LOBBY ENCLOSURE PLAN
FASCIA FRAME
SECTION
CT-2
SECTION
CT-1 SECTION
CT-1
TOP VIEWCT-1 SECTION
Scale: 1:25 m
POLYCARBONATE CANOPY FRAME DET.
3
FASCIA FRAME
DET.
PLYCARBONATE CANOPY FRAMING PLAN
PLYCARBONATE CANOPY FRAMING SECTION
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUG
ARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:25 m
POLYCARBONATE CANOPY FRAMING DET.
4
Scale: 1:25 m
SCHEDULE OF DOORS
1
A7
7 of 30