SlideShare a Scribd company logo
1 of 4
Download to read offline
180555.K Mar 2022
Conductivity Sensors
Cooling Tower Contacting Conductivity Sensors
These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies
with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene sensors are
available with graphite or stainless steel electrodes, and may be installed inline or submersion. High pressure
(up to 300 PSI, 20 bar) inline sensors are constructed from stainless steel and PEEK.
WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to
a voltage that these controllers can read. W400 series controllers use passive sensors that have cables dressed
specifically for them. W100, W900, W600 and Intuition series controller’s passive sensors are dressed differently.
Performance specifications vary with the type of controller, refer to the controller brochure. Typical cooling tower
temperatures are 0 to 70°C, 32 to 158°F.
Boiler Contacting Conductivity Sensors
These cell constant 1.0 sensors are designed for boilers with water up to 30,000 μS/
cm (range varies with solution temperature, see next page) and pressures up to 250 PSI,
16.7 bar). These inline sensors are constructed from stainless steel and PEEK.
For the W100, W400, W900, W600 and Intuition series controllers, a cell constant
10.0 sensor is available designed for boilers with water up to 300,000 μS/cm (range
varies with solution temperature, see below).
WebMaster controllers require active sensors. These sensors contain electronics to
convert the sensor signal to a voltage that these controllers can read. W400, W600, W900 and W100 series
controllers use passive sensors.
Performance specifications vary with the type of controller, refer to the controller brochure. Typical boiler
temperatures are 0 to 205°C, 32 to 401°F.
HP pH/ORP/Steel
0
50
100
150
200
250
300
350
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
°F
Pressure (PSI) vs. Temperature (F)
PSI
-1.1
4.4
10.0
15.5
21.1
26.6
32.2
37.7
43.3
48.8
54.4
60.0
65.5
71.1
76.6
82.2
°C
Bar
24.1
20.7
17.2
13.8
10.3
6.9
3.4
This chart applies to those parts in the charts on pages 2 & 3 that have ‘‘ in
the Temp Range and Pressure Rating columns.
Conductivity Sensors
Contacting
Conductivity Sensors
Contacting conductivity sensors measure conductivity of a solution via electrodes. A variety of cell constants
are available to handle a range of conductivities. They are available in several different configurations:
Contacting conductivity sensors are
ideal for use in cooling towers and
boilers, reverse osmosis equipment,
and other non-oily applications.
Walchem, Iwaki America Inc.
Five Boynton Road Hopping Brook Park | Holliston, MA 01746 USA | Phone 508-429-1110 | walchem.com
About Us
Walchem integrates its advanced sensing, instrumentation,
fluid pumping and communications technologies to deliver
reliable and innovative solutions to the global water
treatment market. Our in-house engineering is driven by
quality, technology and innovation. For more information
on the entire Walchem product line, visit: www.walchem.com
Scan QR code with your
smartphone camera
for more details!
W100/W600/W900
W100/W600/W900/Intuition Contacting Conductivity
General Purpose Contacting Conductivity Sensors (for W100, W900
W600 and Intuition Series Controllers ONLY)
These passive sensors are available in a variety of cell constants for use in conductivities up to
300,000 μS/cm (range varies with solution temperature, see below). Typical applications include
RO systems and boiler condensate monitoring. They may be mounted inline or submersion, using
either polypropylene (0-100 °C, 100 PSI/6.9 bar) or stainless steel (0-120 °C, 200 PSI/13.8 bar)
½” NPT mounting fittings. These inline sensors are constructed from stainless steel and PTFE
with EPR o-rings.
0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9
Temperature °C
Range Multiplier %
Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart.
P/N Description
Cond
Range1
Temp
Range
Pressure
Rating
Materials
Process
Connections
Cable
Length
(Max 250 ft)
Cell
Constant
Temp.
Element
191646-03
Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite
1” NPTM submersion,
3/4” NPTF inline
3 ft
1.0 Thermistor, 10K
191646-20 20 ft
191693-10 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 10 ft 1.0 Thermistor, 10K
191647-03
Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS
1” NPTM submersion,
3/4” NPTF inline
3 ft
1.0 Thermistor, 10K
191647-20 20 ft
190986-05
Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
190986 20 ft
191097-05
Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
191097 20 ft
103061 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 6 ft 1.0 Thermistor, 10K
190984-05
Sensor, Contacting Conductivity, Tower, Graphite, Active 0-30 mS 32-140°F 0-150 PSI PP, Graphite
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
190984 20 ft
191091
Sensor, Contacting Conductivity, Tower, High Pressure,
Active, w/J-Box
0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 Thermistor, 10K
191096-05 Sensor, Contacting Conductivity, Tower, 316SS Electrode,
Active
0-30 mS 32-140°F 0-150 PSI PP, 316SS
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
191096 20 ft
191087
Sensor, Contacting Conductivity, Boiler, ATC, Active,
w/J-Box
0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000
190768 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000
190762 Sensor, Contacting Conductivity, Boiler, ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000
190762-NT Sensor, Contacting Conductivity, Boiler, No ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 N/A
103262 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A
191694 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000
191695 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A
191696 Sensor, Contacting Conductivity, Boiler, ATC 0-300 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 10 RTD, PT1000
103904-10 Sensor, Contacting Conductivity
PP Fitting
0-3 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 0.1 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
103903-10 Sensor, Contacting Conductivity
PP Fitting
0-0.3 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 0.01 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
103905-10 Sensor, Contacting Conductivity
PP Fitting
0-30 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 1.0 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
103906-10 Sensor, Contacting Conductivity
PP Fitting
0-300 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 10.0 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
WCTW1
and
WCT6
COMPATIBLE
CONTROLLERS
WCT4/WDT4
WCNW1
WBLW1
WEBMASTER
WBL4
WCNW1/
WBLW1
Cooling Tower Boiler Condensate / General General
Applications:
* Also compatible with WebMaster w/Preamp Note 1: 1 mS = 1000µS  See graph on page 4
Specifications and Ordering Information
Electrodeless conductivity sensors measure conductivity of a solution utilizing encapsulated, non-contacting,
toroidal technology.
They may be installed in a variety of very harsh chemical control applications, including oily
cleaner baths, chromates, rinse tanks, fume scrubbers and other concentrated chemicals up to
a conductivity of 1000 mS/cm (range varies with solution temperature, see below). The
non-contacting, toroidal sensor technology is immune to thin coatings and the contamination
and calibration problems that direct contacting sensors are prone to.
• CPVC or PEEK construction
• In-line or submersion
W400 and WebMaster controllers require active sensors. These sensors contain electronics
to convert the sensor signal to a voltage that these controllers can read. Each sensor is specific for the range of
conductivity that it can detect (range varies with solution temperature, see below).
0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9
Temperature °C
Range Multiplier %
Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart.
P/N Description
Cond
Range
Temp
Range
Pressure
Rating
Materials
Process
Connections
Cable
Length
Cell
Constant
Temp.
Element
191638-03
Sensor, Electrodeless Conductivity, CPVC 500 µS-2000 mS 20-180°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
3 ft (Max 120 ft)
6.286 RTD, PT1000
191638-20 20 ft (Max 120 ft)
191639-03
Sensor, Electrodeless Conductivity, PEEK 500 µS-2000 mS 32-190°F 0-140 PSI PEEK
1” NPTM submersion,
2” NPTM inline
3 ft (Max 120 ft)
6.286 RTD, PT1000
191639-20 20 ft (Max 120 ft)
191190 Sensor, Electrodeless Conductivity, CPVC, Active 0.1-1 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
190988 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191108 Sensor, Electrodeless Conductivity, CPVC, Active 10-100 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191113 Sensor, Electrodeless Conductivity, CPVC, Active 100-1000 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191191 Sensor, Electrodeless Conductivity, PEEK, Active 0.1-1 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191192 Sensor, Electrodeless Conductivity, PEEK, Active 1-10 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191193 Sensor, Electrodeless Conductivity, PEEK, Active 10-100 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191194 Sensor, Electrodeless Conductivity, PEEK, Active 100-1000 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191474 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A Thermistor, 10K
102730
Sensor, Electrodeless Conductivity, PEEK, Donut
shape
500 µS-1000 mS 20-250°F -15-250 PSI PEEK
3/4”NPTMsubmersion,
2” NPTM inline
20 ft (Max
120 ft)
N/A
Thermistor,
100K
190954 Sensor, Electrodeless Conductivity, CPVC 500 µS-1000 mS 20-180°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
120 ft)
N/A
Thermistor,
100K
191145 Sensor, Electrodeless Conductivity, PEEK 500 µS-1000 mS 32-190°F 0-140 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
120 ft)
N/A
Thermistor,
100K
WCNW1,WCTW1,
WBLW1W1,
W600,
W900,
INT9
COMPATIBLE
CONTROLLERS
Cooling Tower Cooling Tower / General General
Applications:
* Compatible with WECT/WEDT4  See graph on page 4
WebMaster,
WEC/WDEC4
WEC3
Specifications and Ordering Information
*
*
*
*
W600
W900
INT
W600
W900,
INT
W600,
W900,
INT
W100/W600/W90
Electrodeless Conductivity
W100/W600/W900
W100/W600/W900/Intuition Contacting Conductivity
General Purpose Contacting Conductivity Sensors (for W100, W900
W600 and Intuition Series Controllers ONLY)
These passive sensors are available in a variety of cell constants for use in conductivities up to
300,000 μS/cm (range varies with solution temperature, see below). Typical applications include
RO systems and boiler condensate monitoring. They may be mounted inline or submersion, using
either polypropylene (0-100 °C, 100 PSI/6.9 bar) or stainless steel (0-120 °C, 200 PSI/13.8 bar)
½” NPT mounting fittings. These inline sensors are constructed from stainless steel and PTFE
with EPR o-rings.
0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9
Temperature °C
Range Multiplier %
Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart.
P/N Description
Cond
Range1
Temp
Range
Pressure
Rating
Materials
Process
Connections
Cable
Length
(Max 250 ft)
Cell
Constant
Temp.
Element
191646-03
Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite
1” NPTM submersion,
3/4” NPTF inline
3 ft
1.0 Thermistor, 10K
191646-20 20 ft
191693-10 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 10 ft 1.0 Thermistor, 10K
191647-03
Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS
1” NPTM submersion,
3/4” NPTF inline
3 ft
1.0 Thermistor, 10K
191647-20 20 ft
190986-05
Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
190986 20 ft
191097-05
Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
191097 20 ft
103061 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 6 ft 1.0 Thermistor, 10K
190984-05
Sensor, Contacting Conductivity, Tower, Graphite, Active 0-30 mS 32-140°F 0-150 PSI PP, Graphite
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
190984 20 ft
191091
Sensor, Contacting Conductivity, Tower, High Pressure,
Active, w/J-Box
0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 Thermistor, 10K
191096-05 Sensor, Contacting Conductivity, Tower, 316SS Electrode,
Active
0-30 mS 32-140°F 0-150 PSI PP, 316SS
1” NPTM submersion,
3/4” NPTF inline
5 ft
1.0 Thermistor, 10K
191096 20 ft
191087
Sensor, Contacting Conductivity, Boiler, ATC, Active,
w/J-Box
0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000
190768 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000
190762 Sensor, Contacting Conductivity, Boiler, ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000
190762-NT Sensor, Contacting Conductivity, Boiler, No ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 N/A
103262 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A
191694 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000
191695 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A
191696 Sensor, Contacting Conductivity, Boiler, ATC 0-300 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 10 RTD, PT1000
103904-10 Sensor, Contacting Conductivity
PP Fitting
0-3 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 0.1 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
103903-10 Sensor, Contacting Conductivity
PP Fitting
0-0.3 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 0.01 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
103905-10 Sensor, Contacting Conductivity
PP Fitting
0-30 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 1.0 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
103906-10 Sensor, Contacting Conductivity
PP Fitting
0-300 mS
32-212°F 0-100 PSI
316SS, PTFE
1/2” NPTM
Submersion and Inline
10 ft 10.0 RTD, PT1000
SS Fitting 32-248°F 0-200 PSI
WCTW1
and
WCT6
COMPATIBLE
CONTROLLERS
WCT4/WDT4
WCNW1
WBLW1
WEBMASTER
WBL4
WCNW1/
WBLW1
Cooling Tower Boiler Condensate / General General
Applications:
* Also compatible with WebMaster w/Preamp Note 1: 1 mS = 1000µS  See graph on page 4
Specifications and Ordering Information
Electrodeless conductivity sensors measure conductivity of a solution utilizing encapsulated, non-contacting,
toroidal technology.
They may be installed in a variety of very harsh chemical control applications, including oily
cleaner baths, chromates, rinse tanks, fume scrubbers and other concentrated chemicals up to
a conductivity of 1000 mS/cm (range varies with solution temperature, see below). The
non-contacting, toroidal sensor technology is immune to thin coatings and the contamination
and calibration problems that direct contacting sensors are prone to.
• CPVC or PEEK construction
• In-line or submersion
W400 and WebMaster controllers require active sensors. These sensors contain electronics
to convert the sensor signal to a voltage that these controllers can read. Each sensor is specific for the range of
conductivity that it can detect (range varies with solution temperature, see below).
0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9
Temperature °C
Range Multiplier %
Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart.
P/N Description
Cond
Range
Temp
Range
Pressure
Rating
Materials
Process
Connections
Cable
Length
Cell
Constant
Temp.
Element
191638-03
Sensor, Electrodeless Conductivity, CPVC 500 µS-2000 mS 20-180°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
3 ft (Max 120 ft)
6.286 RTD, PT1000
191638-20 20 ft (Max 120 ft)
191639-03
Sensor, Electrodeless Conductivity, PEEK 500 µS-2000 mS 32-190°F 0-140 PSI PEEK
1” NPTM submersion,
2” NPTM inline
3 ft (Max 120 ft)
6.286 RTD, PT1000
191639-20 20 ft (Max 120 ft)
191190 Sensor, Electrodeless Conductivity, CPVC, Active 0.1-1 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
190988 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191108 Sensor, Electrodeless Conductivity, CPVC, Active 10-100 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191113 Sensor, Electrodeless Conductivity, CPVC, Active 100-1000 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191191 Sensor, Electrodeless Conductivity, PEEK, Active 0.1-1 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191192 Sensor, Electrodeless Conductivity, PEEK, Active 1-10 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191193 Sensor, Electrodeless Conductivity, PEEK, Active 10-100 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191194 Sensor, Electrodeless Conductivity, PEEK, Active 100-1000 mS 20-190°F 0-250 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A
Thermistor,
100K
191474 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
250 ft)
N/A Thermistor, 10K
102730
Sensor, Electrodeless Conductivity, PEEK, Donut
shape
500 µS-1000 mS 20-250°F -15-250 PSI PEEK
3/4”NPTMsubmersion,
2” NPTM inline
20 ft (Max
120 ft)
N/A
Thermistor,
100K
190954 Sensor, Electrodeless Conductivity, CPVC 500 µS-1000 mS 20-180°F 0-150 PSI CPVC
1” NPTM submersion,
2” NPTM inline
20 ft (Max
120 ft)
N/A
Thermistor,
100K
191145 Sensor, Electrodeless Conductivity, PEEK 500 µS-1000 mS 32-190°F 0-140 PSI PEEK
1” NPTM submersion,
2” NPTM inline
20 ft (Max
120 ft)
N/A
Thermistor,
100K
WCNW1,WCTW1,
WBLW1W1,
W600,
W900,
INT9
COMPATIBLE
CONTROLLERS
Cooling Tower Cooling Tower / General General
Applications:
* Compatible with WECT/WEDT4  See graph on page 4
WebMaster,
WEC/WDEC4
WEC3
Specifications and Ordering Information
*
*
*
*
W600
W900
INT
W600
W900,
INT
W600,
W900,
INT
W100/W600/W90
Electrodeless Conductivity
180555.K Mar 2022
Conductivity Sensors
Cooling Tower Contacting Conductivity Sensors
These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies
with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene sensors are
available with graphite or stainless steel electrodes, and may be installed inline or submersion. High pressure
(up to 300 PSI, 20 bar) inline sensors are constructed from stainless steel and PEEK.
WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to
a voltage that these controllers can read. W400 series controllers use passive sensors that have cables dressed
specifically for them. W100, W900, W600 and Intuition series controller’s passive sensors are dressed differently.
Performance specifications vary with the type of controller, refer to the controller brochure. Typical cooling tower
temperatures are 0 to 70°C, 32 to 158°F.
Boiler Contacting Conductivity Sensors
These cell constant 1.0 sensors are designed for boilers with water up to 30,000 μS/
cm (range varies with solution temperature, see next page) and pressures up to 250 PSI,
16.7 bar). These inline sensors are constructed from stainless steel and PEEK.
For the W100, W400, W900, W600 and Intuition series controllers, a cell constant
10.0 sensor is available designed for boilers with water up to 300,000 μS/cm (range
varies with solution temperature, see below).
WebMaster controllers require active sensors. These sensors contain electronics to
convert the sensor signal to a voltage that these controllers can read. W400, W600, W900 and W100 series
controllers use passive sensors.
Performance specifications vary with the type of controller, refer to the controller brochure. Typical boiler
temperatures are 0 to 205°C, 32 to 401°F.
HP pH/ORP/Steel
0
50
100
150
200
250
300
350
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
°F
Pressure (PSI) vs. Temperature (F)
PSI
-1.1
4.4
10.0
15.5
21.1
26.6
32.2
37.7
43.3
48.8
54.4
60.0
65.5
71.1
76.6
82.2
°C
Bar
24.1
20.7
17.2
13.8
10.3
6.9
3.4
This chart applies to those parts in the charts on pages 2 & 3 that have ‘‘ in
the Temp Range and Pressure Rating columns.
Conductivity Sensors
Contacting
Conductivity Sensors
Contacting conductivity sensors measure conductivity of a solution via electrodes. A variety of cell constants
are available to handle a range of conductivities. They are available in several different configurations:
Contacting conductivity sensors are
ideal for use in cooling towers and
boilers, reverse osmosis equipment,
and other non-oily applications.
Walchem, Iwaki America Inc.
Five Boynton Road Hopping Brook Park | Holliston, MA 01746 USA | Phone 508-429-1110 | walchem.com
About Us
Walchem integrates its advanced sensing, instrumentation,
fluid pumping and communications technologies to deliver
reliable and innovative solutions to the global water
treatment market. Our in-house engineering is driven by
quality, technology and innovation. For more information
on the entire Walchem product line, visit: www.walchem.com
Scan QR code with your
smartphone camera
for more details!

More Related Content

Similar to Contacting Conductivity Sensors Brochure.pdf

Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-seriesENVIMART
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalogKevin Yang
 
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - BrochureSontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - BrochureThorne & Derrick UK
 
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensorsCondumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensorsENVIMART
 
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...ENVIMART
 
Temperature Sensors used in Pharmaceutical Industry and its application
Temperature Sensors used in Pharmaceutical Industry and its applicationTemperature Sensors used in Pharmaceutical Industry and its application
Temperature Sensors used in Pharmaceutical Industry and its applicationIRJET Journal
 
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensorIndumax cls50 d endress+hauser datasheet-inductive conductivity sensor
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensorENVIMART
 
Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-seriesENVIMART
 
Intuition-9™ Series Water Treatment Controllers Brochure
Intuition-9™ Series Water Treatment Controllers BrochureIntuition-9™ Series Water Treatment Controllers Brochure
Intuition-9™ Series Water Treatment Controllers BrochureWalchem, Iwaki America Inc.
 
Temperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesTemperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesMiller Energy, Inc.
 
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesOrbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesENVIMART
 

Similar to Contacting Conductivity Sensors Brochure.pdf (20)

Thermtest THW-L1
Thermtest THW-L1Thermtest THW-L1
Thermtest THW-L1
 
Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m3000 datasheet badger meter electromagnetic flow meter_m-series
 
Conductivity Sensor for High-Temperature Applications W CLS 13
Conductivity Sensor for High-Temperature Applications W CLS 13Conductivity Sensor for High-Temperature Applications W CLS 13
Conductivity Sensor for High-Temperature Applications W CLS 13
 
Brooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored FlowmeterBrooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored Flowmeter
 
Humidity and temperature sensor module htg3535 ch
Humidity and temperature sensor module   htg3535 chHumidity and temperature sensor module   htg3535 ch
Humidity and temperature sensor module htg3535 ch
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalog
 
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - BrochureSontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
 
Vortex flow meter manual
Vortex flow meter manualVortex flow meter manual
Vortex flow meter manual
 
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensorsCondumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensors
 
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
Omnigrad m tr44 45 endress+hauser datasheet-hygienic, modular rtd assembly-te...
 
Temperature Sensors used in Pharmaceutical Industry and its application
Temperature Sensors used in Pharmaceutical Industry and its applicationTemperature Sensors used in Pharmaceutical Industry and its application
Temperature Sensors used in Pharmaceutical Industry and its application
 
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensorIndumax cls50 d endress+hauser datasheet-inductive conductivity sensor
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor
 
Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
 
Submersible Hydrostatic Level Indicators
Submersible Hydrostatic Level IndicatorsSubmersible Hydrostatic Level Indicators
Submersible Hydrostatic Level Indicators
 
Intuition-9™ Series Water Treatment Controllers Brochure
Intuition-9™ Series Water Treatment Controllers BrochureIntuition-9™ Series Water Treatment Controllers Brochure
Intuition-9™ Series Water Treatment Controllers Brochure
 
Temperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesTemperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential Switches
 
Siemens Duct sensor
Siemens Duct sensorSiemens Duct sensor
Siemens Duct sensor
 
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesOrbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
 
Conductivity sensor High-Temperature Applications CLS50
Conductivity sensor High-Temperature Applications CLS50Conductivity sensor High-Temperature Applications CLS50
Conductivity sensor High-Temperature Applications CLS50
 
PMP131
PMP131PMP131
PMP131
 

More from Walchem, Iwaki America Inc.

Understanding Chemical Dosing Pumps Applications, Types, and Considerations.pdf
Understanding Chemical Dosing Pumps Applications, Types, and Considerations.pdfUnderstanding Chemical Dosing Pumps Applications, Types, and Considerations.pdf
Understanding Chemical Dosing Pumps Applications, Types, and Considerations.pdfWalchem, Iwaki America Inc.
 
WECT400 Series Cooling Tower Conductivity Controller.pdf
WECT400 Series Cooling Tower Conductivity Controller.pdfWECT400 Series Cooling Tower Conductivity Controller.pdf
WECT400 Series Cooling Tower Conductivity Controller.pdfWalchem, Iwaki America Inc.
 
W100 CT-BL Series Cooling Tower and Boiler Controller Manual
W100 CT-BL Series Cooling Tower and Boiler Controller ManualW100 CT-BL Series Cooling Tower and Boiler Controller Manual
W100 CT-BL Series Cooling Tower and Boiler Controller ManualWalchem, Iwaki America Inc.
 

More from Walchem, Iwaki America Inc. (15)

Understanding Chemical Dosing Pumps Applications, Types, and Considerations.pdf
Understanding Chemical Dosing Pumps Applications, Types, and Considerations.pdfUnderstanding Chemical Dosing Pumps Applications, Types, and Considerations.pdf
Understanding Chemical Dosing Pumps Applications, Types, and Considerations.pdf
 
ORP Sensor Troubleshooting Guide
ORP Sensor Troubleshooting GuideORP Sensor Troubleshooting Guide
ORP Sensor Troubleshooting Guide
 
Web Master® WIND Modbus Instruction Manual
Web Master® WIND Modbus Instruction ManualWeb Master® WIND Modbus Instruction Manual
Web Master® WIND Modbus Instruction Manual
 
EWN-R Electromagnetic Metering Pump
EWN-R Electromagnetic Metering PumpEWN-R Electromagnetic Metering Pump
EWN-R Electromagnetic Metering Pump
 
Intuition 6 Instruction Manual
Intuition 6 Instruction ManualIntuition 6 Instruction Manual
Intuition 6 Instruction Manual
 
EZ Series Electronic Metering Pump
EZ Series Electronic Metering PumpEZ Series Electronic Metering Pump
EZ Series Electronic Metering Pump
 
Intuition 6 Water Treatment Controller Manual
Intuition 6 Water Treatment Controller ManualIntuition 6 Water Treatment Controller Manual
Intuition 6 Water Treatment Controller Manual
 
WECT400 Series Cooling Tower Conductivity Controller.pdf
WECT400 Series Cooling Tower Conductivity Controller.pdfWECT400 Series Cooling Tower Conductivity Controller.pdf
WECT400 Series Cooling Tower Conductivity Controller.pdf
 
EHE Series Electronic Metering Pump
EHE Series Electronic Metering PumpEHE Series Electronic Metering Pump
EHE Series Electronic Metering Pump
 
WebMaster ONE Water Treatment Controller Manual
WebMaster ONE Water Treatment Controller ManualWebMaster ONE Water Treatment Controller Manual
WebMaster ONE Water Treatment Controller Manual
 
W100 CT-BL Series Cooling Tower and Boiler Controller Manual
W100 CT-BL Series Cooling Tower and Boiler Controller ManualW100 CT-BL Series Cooling Tower and Boiler Controller Manual
W100 CT-BL Series Cooling Tower and Boiler Controller Manual
 
Intuition 6 Water Treatment Controllers
Intuition 6 Water Treatment ControllersIntuition 6 Water Treatment Controllers
Intuition 6 Water Treatment Controllers
 
EWN-Y Series Metering Pump
EWN-Y Series Metering PumpEWN-Y Series Metering Pump
EWN-Y Series Metering Pump
 
W100W Series Controller Manual.pdf
W100W Series Controller Manual.pdfW100W Series Controller Manual.pdf
W100W Series Controller Manual.pdf
 
W600 Series Controller Manual
W600 Series Controller ManualW600 Series Controller Manual
W600 Series Controller Manual
 

Recently uploaded

Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779Delhi Call girls
 
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...Any kyc Account
 
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒anilsa9823
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear RegressionRavindra Nath Shukla
 
Grateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfGrateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfPaul Menig
 
Understanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key InsightsUnderstanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key Insightsseri bangash
 
Call Girls in Gomti Nagar - 7388211116 - With room Service
Call Girls in Gomti Nagar - 7388211116  - With room ServiceCall Girls in Gomti Nagar - 7388211116  - With room Service
Call Girls in Gomti Nagar - 7388211116 - With room Servicediscovermytutordmt
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Roomdivyansh0kumar0
 
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurVIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurSuhani Kapoor
 
HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsMichael W. Hawkins
 
Monthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxMonthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxAndy Lambert
 
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999Tina Ji
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communicationskarancommunications
 
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLSeo
 
Event mailer assignment progress report .pdf
Event mailer assignment progress report .pdfEvent mailer assignment progress report .pdf
Event mailer assignment progress report .pdftbatkhuu1
 
Unlocking the Secrets of Affiliate Marketing.pdf
Unlocking the Secrets of Affiliate Marketing.pdfUnlocking the Secrets of Affiliate Marketing.pdf
Unlocking the Secrets of Affiliate Marketing.pdfOnline Income Engine
 
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Dave Litwiller
 
Boost the utilization of your HCL environment by reevaluating use cases and f...
Boost the utilization of your HCL environment by reevaluating use cases and f...Boost the utilization of your HCL environment by reevaluating use cases and f...
Boost the utilization of your HCL environment by reevaluating use cases and f...Roland Driesen
 

Recently uploaded (20)

Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
 
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
 
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear Regression
 
Grateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfGrateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdf
 
Understanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key InsightsUnderstanding the Pakistan Budgeting Process: Basics and Key Insights
Understanding the Pakistan Budgeting Process: Basics and Key Insights
 
Call Girls in Gomti Nagar - 7388211116 - With room Service
Call Girls in Gomti Nagar - 7388211116  - With room ServiceCall Girls in Gomti Nagar - 7388211116  - With room Service
Call Girls in Gomti Nagar - 7388211116 - With room Service
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
 
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurVIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
 
HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael Hawkins
 
Monthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxMonthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptx
 
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communications
 
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
 
Forklift Operations: Safety through Cartoons
Forklift Operations: Safety through CartoonsForklift Operations: Safety through Cartoons
Forklift Operations: Safety through Cartoons
 
Event mailer assignment progress report .pdf
Event mailer assignment progress report .pdfEvent mailer assignment progress report .pdf
Event mailer assignment progress report .pdf
 
Unlocking the Secrets of Affiliate Marketing.pdf
Unlocking the Secrets of Affiliate Marketing.pdfUnlocking the Secrets of Affiliate Marketing.pdf
Unlocking the Secrets of Affiliate Marketing.pdf
 
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
 
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
 
Boost the utilization of your HCL environment by reevaluating use cases and f...
Boost the utilization of your HCL environment by reevaluating use cases and f...Boost the utilization of your HCL environment by reevaluating use cases and f...
Boost the utilization of your HCL environment by reevaluating use cases and f...
 

Contacting Conductivity Sensors Brochure.pdf

  • 1. 180555.K Mar 2022 Conductivity Sensors Cooling Tower Contacting Conductivity Sensors These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene sensors are available with graphite or stainless steel electrodes, and may be installed inline or submersion. High pressure (up to 300 PSI, 20 bar) inline sensors are constructed from stainless steel and PEEK. WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to a voltage that these controllers can read. W400 series controllers use passive sensors that have cables dressed specifically for them. W100, W900, W600 and Intuition series controller’s passive sensors are dressed differently. Performance specifications vary with the type of controller, refer to the controller brochure. Typical cooling tower temperatures are 0 to 70°C, 32 to 158°F. Boiler Contacting Conductivity Sensors These cell constant 1.0 sensors are designed for boilers with water up to 30,000 μS/ cm (range varies with solution temperature, see next page) and pressures up to 250 PSI, 16.7 bar). These inline sensors are constructed from stainless steel and PEEK. For the W100, W400, W900, W600 and Intuition series controllers, a cell constant 10.0 sensor is available designed for boilers with water up to 300,000 μS/cm (range varies with solution temperature, see below). WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to a voltage that these controllers can read. W400, W600, W900 and W100 series controllers use passive sensors. Performance specifications vary with the type of controller, refer to the controller brochure. Typical boiler temperatures are 0 to 205°C, 32 to 401°F. HP pH/ORP/Steel 0 50 100 150 200 250 300 350 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 °F Pressure (PSI) vs. Temperature (F) PSI -1.1 4.4 10.0 15.5 21.1 26.6 32.2 37.7 43.3 48.8 54.4 60.0 65.5 71.1 76.6 82.2 °C Bar 24.1 20.7 17.2 13.8 10.3 6.9 3.4 This chart applies to those parts in the charts on pages 2 & 3 that have ‘‘ in the Temp Range and Pressure Rating columns. Conductivity Sensors Contacting Conductivity Sensors Contacting conductivity sensors measure conductivity of a solution via electrodes. A variety of cell constants are available to handle a range of conductivities. They are available in several different configurations: Contacting conductivity sensors are ideal for use in cooling towers and boilers, reverse osmosis equipment, and other non-oily applications. Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park | Holliston, MA 01746 USA | Phone 508-429-1110 | walchem.com About Us Walchem integrates its advanced sensing, instrumentation, fluid pumping and communications technologies to deliver reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality, technology and innovation. For more information on the entire Walchem product line, visit: www.walchem.com Scan QR code with your smartphone camera for more details!
  • 2. W100/W600/W900 W100/W600/W900/Intuition Contacting Conductivity General Purpose Contacting Conductivity Sensors (for W100, W900 W600 and Intuition Series Controllers ONLY) These passive sensors are available in a variety of cell constants for use in conductivities up to 300,000 μS/cm (range varies with solution temperature, see below). Typical applications include RO systems and boiler condensate monitoring. They may be mounted inline or submersion, using either polypropylene (0-100 °C, 100 PSI/6.9 bar) or stainless steel (0-120 °C, 200 PSI/13.8 bar) ½” NPT mounting fittings. These inline sensors are constructed from stainless steel and PTFE with EPR o-rings. 0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9 Temperature °C Range Multiplier % Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart. P/N Description Cond Range1 Temp Range Pressure Rating Materials Process Connections Cable Length (Max 250 ft) Cell Constant Temp. Element 191646-03 Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite 1” NPTM submersion, 3/4” NPTF inline 3 ft 1.0 Thermistor, 10K 191646-20 20 ft 191693-10 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 10 ft 1.0 Thermistor, 10K 191647-03 Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS 1” NPTM submersion, 3/4” NPTF inline 3 ft 1.0 Thermistor, 10K 191647-20 20 ft 190986-05 Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 190986 20 ft 191097-05 Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 191097 20 ft 103061 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 6 ft 1.0 Thermistor, 10K 190984-05 Sensor, Contacting Conductivity, Tower, Graphite, Active 0-30 mS 32-140°F 0-150 PSI PP, Graphite 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 190984 20 ft 191091 Sensor, Contacting Conductivity, Tower, High Pressure, Active, w/J-Box 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 Thermistor, 10K 191096-05 Sensor, Contacting Conductivity, Tower, 316SS Electrode, Active 0-30 mS 32-140°F 0-150 PSI PP, 316SS 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 191096 20 ft 191087 Sensor, Contacting Conductivity, Boiler, ATC, Active, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000 190768 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000 190762 Sensor, Contacting Conductivity, Boiler, ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000 190762-NT Sensor, Contacting Conductivity, Boiler, No ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 N/A 103262 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A 191694 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000 191695 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A 191696 Sensor, Contacting Conductivity, Boiler, ATC 0-300 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 10 RTD, PT1000 103904-10 Sensor, Contacting Conductivity PP Fitting 0-3 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 0.1 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI 103903-10 Sensor, Contacting Conductivity PP Fitting 0-0.3 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 0.01 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI 103905-10 Sensor, Contacting Conductivity PP Fitting 0-30 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 1.0 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI 103906-10 Sensor, Contacting Conductivity PP Fitting 0-300 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 10.0 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI WCTW1 and WCT6 COMPATIBLE CONTROLLERS WCT4/WDT4 WCNW1 WBLW1 WEBMASTER WBL4 WCNW1/ WBLW1 Cooling Tower Boiler Condensate / General General Applications: * Also compatible with WebMaster w/Preamp Note 1: 1 mS = 1000µS  See graph on page 4 Specifications and Ordering Information Electrodeless conductivity sensors measure conductivity of a solution utilizing encapsulated, non-contacting, toroidal technology. They may be installed in a variety of very harsh chemical control applications, including oily cleaner baths, chromates, rinse tanks, fume scrubbers and other concentrated chemicals up to a conductivity of 1000 mS/cm (range varies with solution temperature, see below). The non-contacting, toroidal sensor technology is immune to thin coatings and the contamination and calibration problems that direct contacting sensors are prone to. • CPVC or PEEK construction • In-line or submersion W400 and WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to a voltage that these controllers can read. Each sensor is specific for the range of conductivity that it can detect (range varies with solution temperature, see below). 0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9 Temperature °C Range Multiplier % Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart. P/N Description Cond Range Temp Range Pressure Rating Materials Process Connections Cable Length Cell Constant Temp. Element 191638-03 Sensor, Electrodeless Conductivity, CPVC 500 µS-2000 mS 20-180°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 3 ft (Max 120 ft) 6.286 RTD, PT1000 191638-20 20 ft (Max 120 ft) 191639-03 Sensor, Electrodeless Conductivity, PEEK 500 µS-2000 mS 32-190°F 0-140 PSI PEEK 1” NPTM submersion, 2” NPTM inline 3 ft (Max 120 ft) 6.286 RTD, PT1000 191639-20 20 ft (Max 120 ft) 191190 Sensor, Electrodeless Conductivity, CPVC, Active 0.1-1 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 190988 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191108 Sensor, Electrodeless Conductivity, CPVC, Active 10-100 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191113 Sensor, Electrodeless Conductivity, CPVC, Active 100-1000 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191191 Sensor, Electrodeless Conductivity, PEEK, Active 0.1-1 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191192 Sensor, Electrodeless Conductivity, PEEK, Active 1-10 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191193 Sensor, Electrodeless Conductivity, PEEK, Active 10-100 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191194 Sensor, Electrodeless Conductivity, PEEK, Active 100-1000 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191474 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 10K 102730 Sensor, Electrodeless Conductivity, PEEK, Donut shape 500 µS-1000 mS 20-250°F -15-250 PSI PEEK 3/4”NPTMsubmersion, 2” NPTM inline 20 ft (Max 120 ft) N/A Thermistor, 100K 190954 Sensor, Electrodeless Conductivity, CPVC 500 µS-1000 mS 20-180°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 120 ft) N/A Thermistor, 100K 191145 Sensor, Electrodeless Conductivity, PEEK 500 µS-1000 mS 32-190°F 0-140 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 120 ft) N/A Thermistor, 100K WCNW1,WCTW1, WBLW1W1, W600, W900, INT9 COMPATIBLE CONTROLLERS Cooling Tower Cooling Tower / General General Applications: * Compatible with WECT/WEDT4  See graph on page 4 WebMaster, WEC/WDEC4 WEC3 Specifications and Ordering Information * * * * W600 W900 INT W600 W900, INT W600, W900, INT W100/W600/W90 Electrodeless Conductivity
  • 3. W100/W600/W900 W100/W600/W900/Intuition Contacting Conductivity General Purpose Contacting Conductivity Sensors (for W100, W900 W600 and Intuition Series Controllers ONLY) These passive sensors are available in a variety of cell constants for use in conductivities up to 300,000 μS/cm (range varies with solution temperature, see below). Typical applications include RO systems and boiler condensate monitoring. They may be mounted inline or submersion, using either polypropylene (0-100 °C, 100 PSI/6.9 bar) or stainless steel (0-120 °C, 200 PSI/13.8 bar) ½” NPT mounting fittings. These inline sensors are constructed from stainless steel and PTFE with EPR o-rings. 0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9 Temperature °C Range Multiplier % Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart. P/N Description Cond Range1 Temp Range Pressure Rating Materials Process Connections Cable Length (Max 250 ft) Cell Constant Temp. Element 191646-03 Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite 1” NPTM submersion, 3/4” NPTF inline 3 ft 1.0 Thermistor, 10K 191646-20 20 ft 191693-10 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 10 ft 1.0 Thermistor, 10K 191647-03 Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS 1” NPTM submersion, 3/4” NPTF inline 3 ft 1.0 Thermistor, 10K 191647-20 20 ft 190986-05 Sensor, Contacting Conductivity, Tower, Graphite 0-30 mS 32-140°F 0-150 PSI PP, Graphite 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 190986 20 ft 191097-05 Sensor, Contacting Conductivity, Tower, 316 SS Electrodes 0-30 mS 32-140°F 0-150 PSI PP, 316SS 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 191097 20 ft 103061 Sensor, Contacting Conductivity, Tower, High Pressure 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM 6 ft 1.0 Thermistor, 10K 190984-05 Sensor, Contacting Conductivity, Tower, Graphite, Active 0-30 mS 32-140°F 0-150 PSI PP, Graphite 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 190984 20 ft 191091 Sensor, Contacting Conductivity, Tower, High Pressure, Active, w/J-Box 0-30 mS 32-140°F 0-300 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 Thermistor, 10K 191096-05 Sensor, Contacting Conductivity, Tower, 316SS Electrode, Active 0-30 mS 32-140°F 0-150 PSI PP, 316SS 1” NPTM submersion, 3/4” NPTF inline 5 ft 1.0 Thermistor, 10K 191096 20 ft 191087 Sensor, Contacting Conductivity, Boiler, ATC, Active, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000 190768 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000 190762 Sensor, Contacting Conductivity, Boiler, ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 RTD, PT1000 190762-NT Sensor, Contacting Conductivity, Boiler, No ATC, w/J-Box 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM N/A 1.0 N/A 103262 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A 191694 Sensor, Contacting Conductivity, Boiler, ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 RTD, PT1000 191695 Sensor, Contacting Conductivity, Boiler, No ATC 0-30 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 1.0 N/A 191696 Sensor, Contacting Conductivity, Boiler, ATC 0-300 mS 32-401°F 0-250 PSI 316SS, PEEK 3/4” NPTM 6 inches 10 RTD, PT1000 103904-10 Sensor, Contacting Conductivity PP Fitting 0-3 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 0.1 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI 103903-10 Sensor, Contacting Conductivity PP Fitting 0-0.3 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 0.01 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI 103905-10 Sensor, Contacting Conductivity PP Fitting 0-30 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 1.0 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI 103906-10 Sensor, Contacting Conductivity PP Fitting 0-300 mS 32-212°F 0-100 PSI 316SS, PTFE 1/2” NPTM Submersion and Inline 10 ft 10.0 RTD, PT1000 SS Fitting 32-248°F 0-200 PSI WCTW1 and WCT6 COMPATIBLE CONTROLLERS WCT4/WDT4 WCNW1 WBLW1 WEBMASTER WBL4 WCNW1/ WBLW1 Cooling Tower Boiler Condensate / General General Applications: * Also compatible with WebMaster w/Preamp Note 1: 1 mS = 1000µS  See graph on page 4 Specifications and Ordering Information Electrodeless conductivity sensors measure conductivity of a solution utilizing encapsulated, non-contacting, toroidal technology. They may be installed in a variety of very harsh chemical control applications, including oily cleaner baths, chromates, rinse tanks, fume scrubbers and other concentrated chemicals up to a conductivity of 1000 mS/cm (range varies with solution temperature, see below). The non-contacting, toroidal sensor technology is immune to thin coatings and the contamination and calibration problems that direct contacting sensors are prone to. • CPVC or PEEK construction • In-line or submersion W400 and WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to a voltage that these controllers can read. Each sensor is specific for the range of conductivity that it can detect (range varies with solution temperature, see below). 0 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 181.3 139.9 124.2 111.1 100.0 90.6 82.5 75.5 64.3 55.6 48.9 43.5 39.2 35.7 32.8 30.4 28.5 26.9 25.5 24.4 23.6 22.9 Temperature °C Range Multiplier % Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier chart. P/N Description Cond Range Temp Range Pressure Rating Materials Process Connections Cable Length Cell Constant Temp. Element 191638-03 Sensor, Electrodeless Conductivity, CPVC 500 µS-2000 mS 20-180°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 3 ft (Max 120 ft) 6.286 RTD, PT1000 191638-20 20 ft (Max 120 ft) 191639-03 Sensor, Electrodeless Conductivity, PEEK 500 µS-2000 mS 32-190°F 0-140 PSI PEEK 1” NPTM submersion, 2” NPTM inline 3 ft (Max 120 ft) 6.286 RTD, PT1000 191639-20 20 ft (Max 120 ft) 191190 Sensor, Electrodeless Conductivity, CPVC, Active 0.1-1 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 190988 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191108 Sensor, Electrodeless Conductivity, CPVC, Active 10-100 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191113 Sensor, Electrodeless Conductivity, CPVC, Active 100-1000 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191191 Sensor, Electrodeless Conductivity, PEEK, Active 0.1-1 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191192 Sensor, Electrodeless Conductivity, PEEK, Active 1-10 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191193 Sensor, Electrodeless Conductivity, PEEK, Active 10-100 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191194 Sensor, Electrodeless Conductivity, PEEK, Active 100-1000 mS 20-190°F 0-250 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 100K 191474 Sensor, Electrodeless Conductivity, CPVC, Active 1-10 mS 20-158°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 250 ft) N/A Thermistor, 10K 102730 Sensor, Electrodeless Conductivity, PEEK, Donut shape 500 µS-1000 mS 20-250°F -15-250 PSI PEEK 3/4”NPTMsubmersion, 2” NPTM inline 20 ft (Max 120 ft) N/A Thermistor, 100K 190954 Sensor, Electrodeless Conductivity, CPVC 500 µS-1000 mS 20-180°F 0-150 PSI CPVC 1” NPTM submersion, 2” NPTM inline 20 ft (Max 120 ft) N/A Thermistor, 100K 191145 Sensor, Electrodeless Conductivity, PEEK 500 µS-1000 mS 32-190°F 0-140 PSI PEEK 1” NPTM submersion, 2” NPTM inline 20 ft (Max 120 ft) N/A Thermistor, 100K WCNW1,WCTW1, WBLW1W1, W600, W900, INT9 COMPATIBLE CONTROLLERS Cooling Tower Cooling Tower / General General Applications: * Compatible with WECT/WEDT4  See graph on page 4 WebMaster, WEC/WDEC4 WEC3 Specifications and Ordering Information * * * * W600 W900 INT W600 W900, INT W600, W900, INT W100/W600/W90 Electrodeless Conductivity
  • 4. 180555.K Mar 2022 Conductivity Sensors Cooling Tower Contacting Conductivity Sensors These cell constant 1.0 sensors are designed for cooling towers with water up to 30,000 μS/cm (range varies with solution temperature, see next page). Lower pressure (up to 150 PSI, 10 bar) polypropylene sensors are available with graphite or stainless steel electrodes, and may be installed inline or submersion. High pressure (up to 300 PSI, 20 bar) inline sensors are constructed from stainless steel and PEEK. WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to a voltage that these controllers can read. W400 series controllers use passive sensors that have cables dressed specifically for them. W100, W900, W600 and Intuition series controller’s passive sensors are dressed differently. Performance specifications vary with the type of controller, refer to the controller brochure. Typical cooling tower temperatures are 0 to 70°C, 32 to 158°F. Boiler Contacting Conductivity Sensors These cell constant 1.0 sensors are designed for boilers with water up to 30,000 μS/ cm (range varies with solution temperature, see next page) and pressures up to 250 PSI, 16.7 bar). These inline sensors are constructed from stainless steel and PEEK. For the W100, W400, W900, W600 and Intuition series controllers, a cell constant 10.0 sensor is available designed for boilers with water up to 300,000 μS/cm (range varies with solution temperature, see below). WebMaster controllers require active sensors. These sensors contain electronics to convert the sensor signal to a voltage that these controllers can read. W400, W600, W900 and W100 series controllers use passive sensors. Performance specifications vary with the type of controller, refer to the controller brochure. Typical boiler temperatures are 0 to 205°C, 32 to 401°F. HP pH/ORP/Steel 0 50 100 150 200 250 300 350 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 °F Pressure (PSI) vs. Temperature (F) PSI -1.1 4.4 10.0 15.5 21.1 26.6 32.2 37.7 43.3 48.8 54.4 60.0 65.5 71.1 76.6 82.2 °C Bar 24.1 20.7 17.2 13.8 10.3 6.9 3.4 This chart applies to those parts in the charts on pages 2 & 3 that have ‘‘ in the Temp Range and Pressure Rating columns. Conductivity Sensors Contacting Conductivity Sensors Contacting conductivity sensors measure conductivity of a solution via electrodes. A variety of cell constants are available to handle a range of conductivities. They are available in several different configurations: Contacting conductivity sensors are ideal for use in cooling towers and boilers, reverse osmosis equipment, and other non-oily applications. Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park | Holliston, MA 01746 USA | Phone 508-429-1110 | walchem.com About Us Walchem integrates its advanced sensing, instrumentation, fluid pumping and communications technologies to deliver reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality, technology and innovation. For more information on the entire Walchem product line, visit: www.walchem.com Scan QR code with your smartphone camera for more details!