2. Control panels Catalogue
Swimming pool panel 1 Pump 1 Light
Swimming pool panel 1 Pump 2 Light
S i i l l 1 P 3 Li htSwimming pool panel 1 Pump 3 Light
Swimming pool panel 2 Pump 3 Light
Swimming pool panel 1 Pump 4 Light
Swimming pool panel 2 Pump 4 LightSwimming pool panel 2 Pump 4 Light
Swimming pool panel in plastic enclosure
Swimming pool panel - Waterproof
Custom design
Return to main page
3. Features
Number of Pumps 1
Swimming Pool panel 1Pump 1 Light
Number of Pumps 1
Number of Lights 1
Power of pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
In (A) 7,8,10( ) ,8, 0
Imax (A) 10
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 1.4
V~ (V) 230
V Aux (V) 0
IP 53
Dim. ( H x L x P ) 400x300x200 mm
Return Next Page
4. Features
Swimming Pool panel 1Pump 2 Lights
Number of Pumps 1
Number of Lights 2
Power of Pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
( ) 0 3In (A) 10,11,13
Imax (A) 15
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 1 7Power (kW) 1.7
V~ (V) 230
V Aux (V) 0
IP 53
Dim. ( H x L x P ) 500x400x200 mm
Return Next Page Previous page
5. Features
Number of Pumps 1
Swimming pool panel 1 Pump 3 Lights
Number of Pumps 1
Number of Lights 3
Power of Pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
In (A) 12,13,15( ) , 3, 5
Imax (A) 17
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 2
V~ (V)
230 for single phase or 400
for three phase
V Aux (V) 0
IP 53
Dim. ( H x L x P ) 600x400x200 mm
Return Next Page Previous page
6. Features
Swimming pool panel 2 Pump 3 Lights
Number of Pumps 2
Number of Lights 3
Power of pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/lightg p g
In (A) 20,21,23
Imax (A) 25
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 4
V~ (V)
230 for single phase or 400
for three phase
V Aux (V) 0
IP 53
Dim ( H x L x P ) 600x400x200 mmDim. ( H x L x P ) 600x400x200 mm
Return Next Page Previous page
7. Features
Number of Pumps 1
Swimming pool panel 1 Pump 4 Lights
Number of Pumps 1
Number of Lights 4
Power of Pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
In (A) 14,15,17( ) , ,
Imax (A) 25
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 4
V~ (V)
230 for single phase or 400
for three phase
V Aux (V) 0
IP 53
Dim. ( H x L x P ) 600x500x200 mm
Return Next Page Previous page
8. Features
N b f P 2
Swimming pool panel 2 Pump 4 Lights
Number of Pumps 2
Number of Lights 4
Power of Pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
In (A) 14 15 17In (A) 14,15,17
Imax (A) 25
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 4( )
V~ (V)
230 for single phase or 400
for three phase
V Aux (V) 0
IP 53
Dim. ( H x L x P ) 600x500x200 mm
Return Next Page Previous page
9. Features
Number of Pumps 1
Swimming Pool panel in plastic enclosure
Number of Pumps 1
Number of Lights 1
Power of Pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
In (A) 7,8,10( ) , ,
Imax (A) 10
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 1.4
V~ (V) 230
V Aux (V) 0
IP 53
Dim. ( H x L x P ) 400x300x200 mm
Return Next Page
P iPrevious page
10. Features
Swimming Pool panel Waterproof
Number of Pumps 1
Number of Lights 1 or 2
Power of Pump
(HP) 1,5;2;3
Power of Lights up to 400 VA/light
In (A) 7 8 10In (A) 7,8,10
Imax (A) 10
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 1.7Power (kW) 1.7
V~ (V) 230
V Aux (V) 0
IP 53
Dim. ( H x L x P )
400x300x200 mm
500x400x200 mm
Return Next Page
Previous page
11. Features
Upon Request, we can supply any customized solution to meet your individual requirements
Customized Panels
Panel with 8 lights 400VA and 4 pumps for swimming poolPanel with 3 pumps and water heating for swimming pool
Return Previous page
12. C t l l C t lControl panels Catalogue
Direct on line starter panels: Single-Phase / Three-Phase
Direct on line starter panels: Three PhaseDirect on line starter panels: Three-Phase
Star Delta starter panels
Autotransformer starter panels
Soft Starter Panels
Custom Panels
Return
13. Features
Direct on line Single-Phase / Three-Phase starter panel
Number of pumps 1
Power of pump
(HP) 0,75;1;1,5;2
In (A) 2,4;3,3;4,7;6,5
Imax (A) 10
I (kA) 10Icc (kA) 10
Hz 50
Power (kW) 0,55;0,75;1,1;1,5
V~ (V) 400
V Aux (V) 230
IP 53IP 53
Dim.(HxLxP)mm 185x101x142
Return Next Page
14. Features
Number of pumps 1
Direct on line Three-Phase (1 or 2 pumps) starter panel
Power of pump
(HP) 0,75;1;1,5;2;3;4
In (A) 1;2;2,5;2,9;4,3;5,8
Imax (A) 18
Icc (kA) 10
Hz 50Hz 50
Power (kW) 0,55;0,75;1,1;1,5;2,2;3
V~ (V) 400
V Aux (V) 230
IP 53
Dim (HxLxP)mm 500x400x200Dim.(HxLxP)mm 500x400x200
Return Next Page
Previous page
15. Features
Number of pumps 1
Star Delta Starter Panel
Power of pump
(HP) 5,5;7,5;10;15;20;25;30
In (A) 7,2;10;13,5;20;26,9;33,7;40
Imax (A) 17;25;25;32;32;45;50
I (kA) 10Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 4,1;5,5;7,5;11,2;15;18,5;22
V~ (V) 400V (V) 400
V Aux (V) 0
IP 53
Dim.(HxLxP)mm
500x400x200;600x400x 200;
600x500x200
Return Next Page
Previous page
16. Features
Number of pumps 1
Power of pump
Autotransformer Starter Panel
Power of pump
(HP) 5,5;7,5;10;15;20;25;30
In (A) 7,2;10;13,5;20;26,9;33,7;40
Imax (A) 17;25;25;32;32;45;50
Icc (kA) 10Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 4,1;5,5;7,5;11,2;15;18,5;22
V~ (V) 400
V Aux (V) 0
IP 53
Dim.(HxLxP)mm
500x400x200;600x400x
200;600x500x200
Return Next Page
Previous page
17. Features
Number of pumps 1
Soft Starter Panel
Number of pumps 1
Power of pump
(HP) 5,5;7,5;10;15;20;25;30
In (A) 7,2;10;13,5;20;26,9;33,7;40
Imax (A) 17;25;25;32;32;45;50( ) ; ; ; ; ; ;
Icc (kA) 10
Hz 50
Power (kVA) 0
Power (kW) 4,1;5,5;7,5;11,2;15;18,5;22
V~ (V) 400
V Aux (V) 0
IP 53
Dim. ( H x L x P )
500x400x200;600x400x
200;600x500x200
Return Next Page
P iPrevious page
18. Features
Upon Request, we can supply any customized solution to meet your
individual requirements
Starter for Electric Motors
Return Previous page
20. C t l l C t lControl panels Catalogue
Automatic Control Panels
Automatic Mains Failure
Automatic Transfer Switch
Return
21. Automatic Control Panel
ACP panels rely on the electronic boards that control
the generators. The ACP Panel monitors the Mains
and in the event of failure or irregular power supply,
i h i l h d i hgives the signal to start the generator and switch
the changeover to supply from the generator. Once
the Main Power supply is restored, the ACP's
electronic board will switch the changeover to power
supply from the Mains and initiate the generator's
shutdown process
Return
Next page
shutdown process
22. AMF panels rely on electronic boards that control the
generators. The AMF Panel receives a remote signal
from the ATS panel to start the generator and
Return
Next page
initiates the shutdown process once the signal stops.
Automatic Mains Failure
p g
Previous page
23. ATS panels rely on an electronic board that controlATS panels rely on an electronic board that control
the Mains and give a remote signal for the generator
to start. Once the parameters are stabilized, the
ATS panel makes the changeover. Upon recovery of
the Mains, the ATS Panel will changeover to the
Mains for the generator's shutdown procedure.
Automatic Transfer Switch
Return
Previous page