Fluke Norma Portable, Precision Power Analyzer
Norma 6004+
Norma 6003
Norma 6000 models
Introduction to Norma 6000
3
• What is Norma 6000?
• Norma 6000 is a range of Portable Wideband Precision Power Analyzer, special accessories tosupport the analyzer are
alsoavailable. The Norma 6000 isnotapowerqualityanalyzer it is apower analyzerfor accurate measurements at
frequencies fromDCto500kHz.
• What does Norma 6000 measure?
• It measures AC and DCvoltage, current andpower andallof the associated values with a higher level ofaccuracy than a
power quality meter does
• Why ACandDC?
• For measurements on power conversion systems such as inverters, output ofphotovoltaic array,DCturbines (wind),
transportation systems
• What accuracy?
• Voltage - 0.1%, current - 0.1%
• How is this different from the Norma analyzers in the Fluke range?
• The 6000 model is designed tobe used in the field, its rugged, battery operated, lightweight andsuited touse outside ofa
laboratoryenvironment
• How is this different from other PQ analyzers?
• The analyzer can measure variable frequency systems andoperates over a wide rangeof frequencies, its measurements are
not based on requirements offixed power systems but particularly useful on power conversion systems like variable
frequency drives orUPS systems.
Where does Norma 6000 fit in ourrange?
4
• PQ Analyzersare used for measurements primarilyon the ACpower network.
• Norma 6000can beused on clean power side of generation as this is mostly DC
Clean, Renewable Gen. (Wind, Solar,Battery Storage)
AC
DC
DC
DC
- +
DC
AC
Traditional generation, transmission and distribution
PQAnalyzers:
PQAnalyzerthatcan captureeventsandcheck
conformancetoindustrystandards.Usedby Utility
Eng.totestinfluenceonPowerQualityat couplingto
grid(utility)
UsuallyPre-andPostinstalltests
Norma6000:
Widebandwidth,accuratepoweranalyzer,Used
byOEM’s &OperatorOwnerstotestefficiency
and conversionperformanceoftheasset
Here’s thegeneration side, there
is moreon the load side required
too
Norma 6000is not a
power quality analyzer
Key Attributes
5
• Large, bright display
• Compact, Lightweight (6lbs), easy to carry,optimum carryingcase design
• Battery powered (BP291)
• Simplified userinterface (keypad and context based functionkeys)
• Direct and probe/clamp inputs
• Optimized application based accessories
• 200kHzsampling, 500kHzbandwidth
• Voltage, currentand power harmonicsup to the 100th
• FFT function for graphical spectrum up to 100kHz
• Useradjustable measurement ratefrom 100msto 1s with continuouslogging via 32GB of onboard storage.
• Double instrumentsynchronization to extend measurements to 8 channels
• CAT IV600V,CAT III1,000Vsafety rating
• PC Application software for download of measured data and screens and instrumentsetup
Internal use only
Key Attributes
6
• Doesn’t rely on afixed frequency (50/60Hz) formeasurement
• Suitable for variablefrequency devices like inverters (variable frequency drives, UPSsystems, power converted (AC-DC,
AC-AC,DC-ACandDC-DC)
• High frequency measurements >>1kHz
• Large display for METER,SCOPE,TREND, PHASOR andHARMONICS
Internal use only
Models
Norma6000Models
• Norma6003(+) threevoltageandthree
currentchannels
• Norma6004(+)fourvoltageandfour
currentchannels
• Switching direct currentinput (range:10A)to
external BNCinput via slider
• + models include:
– Mechanical input interface
– 1 speed interface
– 1torque interface
+ model optional inputs
7
Key Attributes
8
• In-built shunt forAC/DC current up to10A
• Voltage input forcurrent probes, current transformers etc. –POKAYOKE toprevent hazardous connections
Internal use only
• New Accessories:
• 2,000A AC/DCcurrent clamp
• 1,500V DCmodule
Renewable Energy Electric Vehicles R&D, Education and
3rd party Labs
Manufacturing
Application Maintenance of frequency
generators/transducers in
wind power farms/solar
power farms
Electric vehicles charging
stations, batteries, inverters,
motor efficiency testing and
performance evaluation
test.
In-field power & efficiency
evaluation of inverters,
variable voltage, variable
frequency equipment.
Power, harmonics and
transformer load loss test in
the lab and field.
Used in production
environment, for product
inspection of industrial
electrical appliances and
equipment, mechanic
products and frequency
conversion devices.
End User • 3rd party maintenance
contractors
• Wind/solar power farm
• Frequency converter
suppliers
• Frequency converter
suppliers
• Transducer suppliers
• Test technicians and
engineers
• Quality assurance
technicians
• R&D engineer
• Product evaluation
engineer
• Testing engineer
• QA Test Engineer and
technicians
• Maintenance engineer
Personas The technicians don’t always have rich technical knowledge in power analysis, but just follow standard
routines and work instructions, they may use a variety of tools to detect if there is any out. They work
in field not lab and they need easy-to-use tools. For component supplier and third party service
provider, they have a wide range of clients and they work in customer facility.
Where willit be used and by who?
9
Pain
Points
Fluke
Value
Carry Poweranalyzer to
thefield
Set up wire
connection
Pluginpower Operate testing Read and record
data
Heavy tools &
accessories to carry to
difficult to access
locations
Complicated wiring
connection and setup
No ACpower
source in field
Oversized
Narrowworking space
Read from
complicated UI,difficult
to use
Light tool
Suitable for:outdoor,
climbing and long
walking distances
1.Illustrated connection
guide.
2.Poka-yoke connection
slide.
3.Doesn’t needadditional
adapters for motor testing.
Small size
Suitable forsmall
working space
User-friendly UI:
intuitive menu
structure and hot keys
forhigh frequentused
function
Workflow
Embedded
Battery
Usable in locations
without regular
poweroutlets.
Portable EasyofUse EasyUsePortable
Customer Workflow / Pain Points – In-Field
connect accessory to
PA
No large clamp-on current
sensorswith high accuracy
available
LargeAC/DC clamp-on
sensorfrom Fluke(50mm,
0.3%;80mm,0.5%)
LargeAC sensorwith
1,000Arangeand 0.1%
accuracy.
4
Who can use Norma 6000 and where?
Application/ Measuretarget Inverters Powergenerator
Frequencyconvertors/
motors
EV – Vehicle&electronic
control/motor
EVSE(vehiclecharging
system)
Others
Location Field Lab Field Lab Field Lab Field Lab Field Lab Field Lab
Users
R&D Yes Yes Yes Yes Yes Yes
Service Yes Yes Yes
Operation Yes Yes Yes
3rdpartylabs Yes Yes Yes Yes Yes Yes Yes Yes
Power Analyzer Users byApplication/Usage
Useone solutiontomeetbothFieldand Labneeds
• Therearefieldandlabuses ineachapplicationsegment
• End usershavedifferentrequirementinfieldandlab,mainlyfocusedoneaseofportabilityand batterypower
• Normaportableissolutionforin-fieldapplications,whichcan servelow endlab usagetoo
PowerAnalyzer Segmentationby Spec (Channel & Voltage)
NormaPortabletargetslow-mediumend segmentdue toits4channeland1000Vvoltagerangespec
• Amongallspecifications,channel& voltagearetwokeydifferencestodistinguishhighend fromlow end
• Ineachofthose6applications,therearewiderangeofuserneedsfromhigh-endtolow-end
The Norma 6000 analyzer isan idealportabletool for making accurate power measurements on DC to 10’s of kHz AC.
Features and specifications
Feature N6003 N6003+ N6004 N6004+
Channels for voltage and current 3+3 3+3 4+4 4+4
Motor Speed/Torque measurement - • - •
Basic voltage accuracy
Bandwidth
Sampling rate
Channel-channel isolation
Numeric display ( V / I / P /η etc.)
Harmonics
Oscilloscope waveform display
Trend Recorder mode
Frequency domain display and measurement
Vector display
Category rating
Over-range protection
IP rating
Color Screen (TFT)
Li-ion Battery
Power adapter
PC Application software
Communications
Instrument to Instrument synchronization
Auto power off
Battery type
Low battery indicator
CAT III 1000V, CAT IV 600V
0.10%
500kHz (For high voltage/current range )
200kHz
• (CMMR DC >110dB and AC>120dB)
•
•
100 (FFT and DFT)
• (Master/Slave mode)
BP291
• (10% input OL protection, OL Indication)
• (downloading, analysis and reporting)
USB (Device) – Mini B, RS485 (instrument sync and download)
• (selectable)
IEC 60529: IP 50 (Terminals Mated)
5.7” backlight,4:3 (640 x 480 pixels)
>54Wh, typically 10 hours use
Charger / Power Supply
•
•
•
•
12
Why is the Norma 6000 anattractive product?
13
Features Benefits
Batterypoweredforportability Usablein inaccessiblelocationswherepower outletsareunavailable
Easyto carry case,small andlightweight, shoulderstrap Suitableforthoseenvironment:outdoor,smallspace, claiming,longwalking distance
UserfriendlyUI (clearmenustructure andconnectionguide) Easyoperationto improve productivity
GuidedconnectionandPoka-yokeconnectionslide Easy, correct connectionwith enhancedsafety
Accessories -Large AC/DCsensorfrom Fluke(50mm,0.3%; 80mm, 0.5%) and
precise0.1% 1,000A clamp
Measurementsonlargeconductors
CAT IV 600Vrating foranalyzer,CATIII600V forsensors Ensureusersafety
Multipleinstrumentsynchronization,andsimplified connectionfor torqueand
rotationspeed(motor)
Provideflexibilityto usersto extendnumber of channelsfor extendedapplications
Bandwidthfrom DC to 500kHz.Voltage, currentand powerharmonicsupto
the 100th;measurementof active power, reactivepower,power factor;
supportingDigital Oscilloscope(DSO)mode.
Meetcustomerbasicmeasurementrequirement,covering target applicationof
inverter,variable-voltage& variable-frequency(VVVF) devices etc.
Fortestengineersandservicetechnicianswhoworkonrenewableenergy,electricvehicle, manufacturingindustry,R&D,serviceorganizationsandthe
thirdpartylaboratories,theFlukeportablepoweranalyzerprovidestheeasiesttouse toolformeasuringpowerparameterstodetectproblems,thisallows
theuserstoperformthesemeasurementsquicklyandefficientlyinthefield.
Fluke Product Comparison
Feature N6003 N6003+ N6004 N6004+ 438-II 190-504 MDA-550 N4K-3PP42 N4K-3PP42IP N5K-4PP54IP
Channels forvoltage and current 3+3 3+3 4+4 4+4 4+4 4 2 3+3 3+3 4+4
Motor Speed/Torquemeasurement - • - • • - - - • •
Non-sensor torqueand speed - - - - • - - - - -
Guided connection • • • • - - • - - -
Batteryoperated • • • • • • • - - -
Basic voltage and current accuracy 0.1%/0.1% 0.1%/0.5% 1.5%/1.5% 0.1%/0.1% 0.05%/0.05%
Bandwidth 500kHz(Forhigh voltage/current range) >10kHz 500MHz 341kHz
Sampling rate 200kHz 200kHz 5GS/s 3MHz
Channel-channel isolation (CMMR -Common
Mode Rejection Ratio)
DC >110dBand AC>120dB N/A DC >100dBand AC>60dB) 120dBat 100kHz
Numericdisplay ( V/I/ P/η etc.) • • • • • • •
Oscilloscope waveformdisplay • • • • • • •
TrendRecorder mode • • • • • • •
Harmonics 100(FFTand DFT) 50 50(and FFT) 50(FFTand DFT)
Frequencyharmonic domain measurementand
display
• - • • • • •
IEC61000-4-7Harmonics - • - - • • •
Events - • - - - - -
Vectordisplay • • - - • • •
Categoryrating CAT IV600V • • • • - - -
Categoryrating CAT III600V - - - - • • •
Color Screen(TFT)5.7”backlight,4:3 640x 480 320x 240 320x 240 320x 240
PCApplication software-Downloading, analysis,
reporting and instrument control
FlukeNorma PowerAnalyze PowerLog 430 FlukeView NormaView & LabViewdrivers
USB (Device) – Mini B • • • • • • •
RS485 •(Communication speedup to 230,400bps) - - - - • •
InstrumenttoInstrumentsynchronization •(Master/Slavemode) - - - - - -
14
Why users love the Norma 6000
15
• TheNorma brand is widely knownandaccepted as a markof quality and precision in power measurement.
• Theexisting measurementsolutions are not optimized for portability, which makes the emerging need for accurate
power measurementson electronic loads inthe field difficult and timeconsuming, this solution is optimized for field
use with easy to use UI,lightweight, small size and battery power.
• Thenew AC/DCclamp-oncurrentsensors are easy to install infield applications and offer an accuracyon not
offered by the clamp-oncurrentsensors available today.
• Similarly the ACcurrentsensor offers better accuracythan is currentlyavailable.
• Measurement accuracyis important to users as they are performing efficiencymeasurements where accuracyis
critical.
• Theoptional availability of torque and speed measurementinputs give real time mechanical and electrical
information that can show efficiencyin real conditions as loads vary.
• Thetarget users in operational maintenance,service and commissioning are well served by Flukewith adjacent
measurementsolutions includingPQ analyzers, Scopemeters and motor driveanalyzers – this product is usedfor
and an additional measurement and analysis requirementnot served by those other products.
Additional Questions or Comments?
Email Christina Spearman christina.spearman@transcat.com
Transcat: 800-828-1470
www.transcat.com
For related product information, go to:
https://www.transcat.com/brand/fluke-store

Introduction to Portable Precision Power Analyzers Presented by Fluke

  • 1.
    Fluke Norma Portable,Precision Power Analyzer Norma 6004+ Norma 6003 Norma 6000 models
  • 3.
    Introduction to Norma6000 3 • What is Norma 6000? • Norma 6000 is a range of Portable Wideband Precision Power Analyzer, special accessories tosupport the analyzer are alsoavailable. The Norma 6000 isnotapowerqualityanalyzer it is apower analyzerfor accurate measurements at frequencies fromDCto500kHz. • What does Norma 6000 measure? • It measures AC and DCvoltage, current andpower andallof the associated values with a higher level ofaccuracy than a power quality meter does • Why ACandDC? • For measurements on power conversion systems such as inverters, output ofphotovoltaic array,DCturbines (wind), transportation systems • What accuracy? • Voltage - 0.1%, current - 0.1% • How is this different from the Norma analyzers in the Fluke range? • The 6000 model is designed tobe used in the field, its rugged, battery operated, lightweight andsuited touse outside ofa laboratoryenvironment • How is this different from other PQ analyzers? • The analyzer can measure variable frequency systems andoperates over a wide rangeof frequencies, its measurements are not based on requirements offixed power systems but particularly useful on power conversion systems like variable frequency drives orUPS systems.
  • 4.
    Where does Norma6000 fit in ourrange? 4 • PQ Analyzersare used for measurements primarilyon the ACpower network. • Norma 6000can beused on clean power side of generation as this is mostly DC Clean, Renewable Gen. (Wind, Solar,Battery Storage) AC DC DC DC - + DC AC Traditional generation, transmission and distribution PQAnalyzers: PQAnalyzerthatcan captureeventsandcheck conformancetoindustrystandards.Usedby Utility Eng.totestinfluenceonPowerQualityat couplingto grid(utility) UsuallyPre-andPostinstalltests Norma6000: Widebandwidth,accuratepoweranalyzer,Used byOEM’s &OperatorOwnerstotestefficiency and conversionperformanceoftheasset Here’s thegeneration side, there is moreon the load side required too Norma 6000is not a power quality analyzer
  • 5.
    Key Attributes 5 • Large,bright display • Compact, Lightweight (6lbs), easy to carry,optimum carryingcase design • Battery powered (BP291) • Simplified userinterface (keypad and context based functionkeys) • Direct and probe/clamp inputs • Optimized application based accessories • 200kHzsampling, 500kHzbandwidth • Voltage, currentand power harmonicsup to the 100th • FFT function for graphical spectrum up to 100kHz • Useradjustable measurement ratefrom 100msto 1s with continuouslogging via 32GB of onboard storage. • Double instrumentsynchronization to extend measurements to 8 channels • CAT IV600V,CAT III1,000Vsafety rating • PC Application software for download of measured data and screens and instrumentsetup Internal use only
  • 6.
    Key Attributes 6 • Doesn’trely on afixed frequency (50/60Hz) formeasurement • Suitable for variablefrequency devices like inverters (variable frequency drives, UPSsystems, power converted (AC-DC, AC-AC,DC-ACandDC-DC) • High frequency measurements >>1kHz • Large display for METER,SCOPE,TREND, PHASOR andHARMONICS Internal use only
  • 7.
    Models Norma6000Models • Norma6003(+) threevoltageandthree currentchannels •Norma6004(+)fourvoltageandfour currentchannels • Switching direct currentinput (range:10A)to external BNCinput via slider • + models include: – Mechanical input interface – 1 speed interface – 1torque interface + model optional inputs 7
  • 8.
    Key Attributes 8 • In-builtshunt forAC/DC current up to10A • Voltage input forcurrent probes, current transformers etc. –POKAYOKE toprevent hazardous connections Internal use only • New Accessories: • 2,000A AC/DCcurrent clamp • 1,500V DCmodule
  • 9.
    Renewable Energy ElectricVehicles R&D, Education and 3rd party Labs Manufacturing Application Maintenance of frequency generators/transducers in wind power farms/solar power farms Electric vehicles charging stations, batteries, inverters, motor efficiency testing and performance evaluation test. In-field power & efficiency evaluation of inverters, variable voltage, variable frequency equipment. Power, harmonics and transformer load loss test in the lab and field. Used in production environment, for product inspection of industrial electrical appliances and equipment, mechanic products and frequency conversion devices. End User • 3rd party maintenance contractors • Wind/solar power farm • Frequency converter suppliers • Frequency converter suppliers • Transducer suppliers • Test technicians and engineers • Quality assurance technicians • R&D engineer • Product evaluation engineer • Testing engineer • QA Test Engineer and technicians • Maintenance engineer Personas The technicians don’t always have rich technical knowledge in power analysis, but just follow standard routines and work instructions, they may use a variety of tools to detect if there is any out. They work in field not lab and they need easy-to-use tools. For component supplier and third party service provider, they have a wide range of clients and they work in customer facility. Where willit be used and by who? 9
  • 10.
    Pain Points Fluke Value Carry Poweranalyzer to thefield Setup wire connection Pluginpower Operate testing Read and record data Heavy tools & accessories to carry to difficult to access locations Complicated wiring connection and setup No ACpower source in field Oversized Narrowworking space Read from complicated UI,difficult to use Light tool Suitable for:outdoor, climbing and long walking distances 1.Illustrated connection guide. 2.Poka-yoke connection slide. 3.Doesn’t needadditional adapters for motor testing. Small size Suitable forsmall working space User-friendly UI: intuitive menu structure and hot keys forhigh frequentused function Workflow Embedded Battery Usable in locations without regular poweroutlets. Portable EasyofUse EasyUsePortable Customer Workflow / Pain Points – In-Field connect accessory to PA No large clamp-on current sensorswith high accuracy available LargeAC/DC clamp-on sensorfrom Fluke(50mm, 0.3%;80mm,0.5%) LargeAC sensorwith 1,000Arangeand 0.1% accuracy. 4
  • 11.
    Who can useNorma 6000 and where? Application/ Measuretarget Inverters Powergenerator Frequencyconvertors/ motors EV – Vehicle&electronic control/motor EVSE(vehiclecharging system) Others Location Field Lab Field Lab Field Lab Field Lab Field Lab Field Lab Users R&D Yes Yes Yes Yes Yes Yes Service Yes Yes Yes Operation Yes Yes Yes 3rdpartylabs Yes Yes Yes Yes Yes Yes Yes Yes Power Analyzer Users byApplication/Usage Useone solutiontomeetbothFieldand Labneeds • Therearefieldandlabuses ineachapplicationsegment • End usershavedifferentrequirementinfieldandlab,mainlyfocusedoneaseofportabilityand batterypower • Normaportableissolutionforin-fieldapplications,whichcan servelow endlab usagetoo PowerAnalyzer Segmentationby Spec (Channel & Voltage) NormaPortabletargetslow-mediumend segmentdue toits4channeland1000Vvoltagerangespec • Amongallspecifications,channel& voltagearetwokeydifferencestodistinguishhighend fromlow end • Ineachofthose6applications,therearewiderangeofuserneedsfromhigh-endtolow-end The Norma 6000 analyzer isan idealportabletool for making accurate power measurements on DC to 10’s of kHz AC.
  • 12.
    Features and specifications FeatureN6003 N6003+ N6004 N6004+ Channels for voltage and current 3+3 3+3 4+4 4+4 Motor Speed/Torque measurement - • - • Basic voltage accuracy Bandwidth Sampling rate Channel-channel isolation Numeric display ( V / I / P /η etc.) Harmonics Oscilloscope waveform display Trend Recorder mode Frequency domain display and measurement Vector display Category rating Over-range protection IP rating Color Screen (TFT) Li-ion Battery Power adapter PC Application software Communications Instrument to Instrument synchronization Auto power off Battery type Low battery indicator CAT III 1000V, CAT IV 600V 0.10% 500kHz (For high voltage/current range ) 200kHz • (CMMR DC >110dB and AC>120dB) • • 100 (FFT and DFT) • (Master/Slave mode) BP291 • (10% input OL protection, OL Indication) • (downloading, analysis and reporting) USB (Device) – Mini B, RS485 (instrument sync and download) • (selectable) IEC 60529: IP 50 (Terminals Mated) 5.7” backlight,4:3 (640 x 480 pixels) >54Wh, typically 10 hours use Charger / Power Supply • • • • 12
  • 13.
    Why is theNorma 6000 anattractive product? 13 Features Benefits Batterypoweredforportability Usablein inaccessiblelocationswherepower outletsareunavailable Easyto carry case,small andlightweight, shoulderstrap Suitableforthoseenvironment:outdoor,smallspace, claiming,longwalking distance UserfriendlyUI (clearmenustructure andconnectionguide) Easyoperationto improve productivity GuidedconnectionandPoka-yokeconnectionslide Easy, correct connectionwith enhancedsafety Accessories -Large AC/DCsensorfrom Fluke(50mm,0.3%; 80mm, 0.5%) and precise0.1% 1,000A clamp Measurementsonlargeconductors CAT IV 600Vrating foranalyzer,CATIII600V forsensors Ensureusersafety Multipleinstrumentsynchronization,andsimplified connectionfor torqueand rotationspeed(motor) Provideflexibilityto usersto extendnumber of channelsfor extendedapplications Bandwidthfrom DC to 500kHz.Voltage, currentand powerharmonicsupto the 100th;measurementof active power, reactivepower,power factor; supportingDigital Oscilloscope(DSO)mode. Meetcustomerbasicmeasurementrequirement,covering target applicationof inverter,variable-voltage& variable-frequency(VVVF) devices etc. Fortestengineersandservicetechnicianswhoworkonrenewableenergy,electricvehicle, manufacturingindustry,R&D,serviceorganizationsandthe thirdpartylaboratories,theFlukeportablepoweranalyzerprovidestheeasiesttouse toolformeasuringpowerparameterstodetectproblems,thisallows theuserstoperformthesemeasurementsquicklyandefficientlyinthefield.
  • 14.
    Fluke Product Comparison FeatureN6003 N6003+ N6004 N6004+ 438-II 190-504 MDA-550 N4K-3PP42 N4K-3PP42IP N5K-4PP54IP Channels forvoltage and current 3+3 3+3 4+4 4+4 4+4 4 2 3+3 3+3 4+4 Motor Speed/Torquemeasurement - • - • • - - - • • Non-sensor torqueand speed - - - - • - - - - - Guided connection • • • • - - • - - - Batteryoperated • • • • • • • - - - Basic voltage and current accuracy 0.1%/0.1% 0.1%/0.5% 1.5%/1.5% 0.1%/0.1% 0.05%/0.05% Bandwidth 500kHz(Forhigh voltage/current range) >10kHz 500MHz 341kHz Sampling rate 200kHz 200kHz 5GS/s 3MHz Channel-channel isolation (CMMR -Common Mode Rejection Ratio) DC >110dBand AC>120dB N/A DC >100dBand AC>60dB) 120dBat 100kHz Numericdisplay ( V/I/ P/η etc.) • • • • • • • Oscilloscope waveformdisplay • • • • • • • TrendRecorder mode • • • • • • • Harmonics 100(FFTand DFT) 50 50(and FFT) 50(FFTand DFT) Frequencyharmonic domain measurementand display • - • • • • • IEC61000-4-7Harmonics - • - - • • • Events - • - - - - - Vectordisplay • • - - • • • Categoryrating CAT IV600V • • • • - - - Categoryrating CAT III600V - - - - • • • Color Screen(TFT)5.7”backlight,4:3 640x 480 320x 240 320x 240 320x 240 PCApplication software-Downloading, analysis, reporting and instrument control FlukeNorma PowerAnalyze PowerLog 430 FlukeView NormaView & LabViewdrivers USB (Device) – Mini B • • • • • • • RS485 •(Communication speedup to 230,400bps) - - - - • • InstrumenttoInstrumentsynchronization •(Master/Slavemode) - - - - - - 14
  • 15.
    Why users lovethe Norma 6000 15 • TheNorma brand is widely knownandaccepted as a markof quality and precision in power measurement. • Theexisting measurementsolutions are not optimized for portability, which makes the emerging need for accurate power measurementson electronic loads inthe field difficult and timeconsuming, this solution is optimized for field use with easy to use UI,lightweight, small size and battery power. • Thenew AC/DCclamp-oncurrentsensors are easy to install infield applications and offer an accuracyon not offered by the clamp-oncurrentsensors available today. • Similarly the ACcurrentsensor offers better accuracythan is currentlyavailable. • Measurement accuracyis important to users as they are performing efficiencymeasurements where accuracyis critical. • Theoptional availability of torque and speed measurementinputs give real time mechanical and electrical information that can show efficiencyin real conditions as loads vary. • Thetarget users in operational maintenance,service and commissioning are well served by Flukewith adjacent measurementsolutions includingPQ analyzers, Scopemeters and motor driveanalyzers – this product is usedfor and an additional measurement and analysis requirementnot served by those other products.
  • 16.
    Additional Questions orComments? Email Christina Spearman christina.spearman@transcat.com Transcat: 800-828-1470 www.transcat.com For related product information, go to: https://www.transcat.com/brand/fluke-store