1 Abstract
Wind load governs the design of the mounting structures of solar panels which constitute
approximately 10 to 15 percent of the total project cost. Wind load design of the ground-mounted
photovoltaic (PV) power plants requires interpretation of the design code considering the
particularities of these structures. Structural failures of utility scale PV plants are rare events, but
some failures have still been observed in code-compliant structures.
Wind loads are calculated using the static pressure coefficients provided in national as well as
international design standards. In the Indian Solar industry, the wind loads are applied uniformly
over the entire panel, acting as monoslope canopy, based on older version of IS875: Part 3. This
paper demonstrates that this is not a precise method of wind load application and; provides a
detailed description of eccentrically distributed wind load application based on IS 875: Part 3
(2015) and various other international design codes.
2 Introduction
Over last decade, solar PV industry has endured remarkable advancement in terms of both
efficiency and cost reduction. PV module is the key component of a solar PV plant, however it
should be noted that the module mounting structure plays an equally critical role in reliability and
durability of solar PV plants that have designed life of more than 25 years.
The falling tariff trend has posed pressure on balance of system (BoS) cost and module mounting
structure is most sought after plant equipment which are being compromised in order to cut down
the cost of the project. This is usually done by reducing the section sizes of the supporting module
mounting structure.
The prospect of reducing the overall project cost is good, however as per SgurrEnergy’s experience
the focus has been on reducing the weight of the structure while the strength of the structure to
sustain the gust of wind are being compromised. Focusing on the evidences from India, there have
been numerous incidences of MMS failures at lower wind speed.
Structural failures have been observed in code-compliant ground-mounted systems during wind
events at wind speeds significantly less than design wind speed. The current industrial research has
been focused on determining the cause of failure in otherwise code-compliant structures and
improving correct method of application of wind loads.
Figure 2-1: Failure of the complete Module Mounting table under wind loading
Source: www.rmi.org
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 2 of 11
Figure 2-2: Failure of the part of Module Mounting Structure under wind loading
Source: pv-magazine-usa.com
Application of wind load governs the design of the module mounting structure. Due to lack of solar
specific design code, most designers typically follow the design procedures recommended by
building codes meant for large sloped roofs. This may lead to inappropriate and inaccurate results
leading to unsafe designs. Though, the current wind design standards have a very wide scale of
applications, they do not cover solar specific wind design guidelines.
Through this paper SgurrEnergy intends to presents the precise and specific method of application
of wind loading on the mounting structure with reference to explicit notes provided in the Indian
design standards and international standards.
3 Eccentric Wind Loading – A Technical Investigation
Several designs elements are required to be considered during MMS design. Application of wind
load is one such important element which is generally compromised. The current industry trend of
MMS design is to assume wind pressure acting uniformly over the entire solar panel, such that the
force acts at the centre of the distributed area as shown in the figure below.
Figure 3-1: Uniform Wind load distribution
Here, w= Length of entire assembly/ canopy.
SgurrEnergy would like to call/draw attention to the note provided below the Table 8 of IS 875
(Part 3): 2015 states that the wind load shall be applied in such a way that the centre of pressure
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 3 of 11
shall act at 0.3w from windward edge and not at the centre of entire assembly (0.5w). Furthermore,
Table 8 of IS 875 (Part 3): 2015 provides the pressure coefficients for mono-slope free roofs. As
illustrated in figure below, code also provides the method of application of load.
The note number 1 implies that the load application on mono-pitch canopies shall not be uniformly
distributed load. The pressure/load shall act eccentrically on surface. Figure below illustrates the
load application in accordance with the code requirements.
Figure 3-2: Eccentric Wind load distribution
4 Methodology and Sample Study
In this part of the paper, SgurrEnergy intends to explicate the procedure to calculate forces on
purlins of the module mounting structures for uniform and eccentric wind loading through a case
study.
Case Study: The description of the MMS under consideration is as follows,
The Table configuration is 2Px30 and the fixed tilt is 20°. The Module size 2108mm x 1048mm x
40mm having weight 24.9kg separated by distance of 20mm. The structure lies in the region of
basic wind speed 47m/s.
As per IS 875 (3): 2015,
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 4 of 11
Design wind speed Vz = K1 K2 K3 K4 Vb
Basic wind speed Vb = 47m/s
Risk coefficient K1 = 0.9
Terrain, height and structure size factor K2 = 1.0
Topography factor K3 = 1.0
Importance factor K4 = 1.0
Hence, Vz = 42.30m/s
Basic Wind Pressure Pd = 0.6 Vz2
Pd = 1.074KN/m2
Design Wind pressure Pz = Kd Ka Kc Pd
Wind directionality factor Kd = 0.9
Area averaging factor Ka = 1.0
Combination factor Kc = 1.0
Hence, Pz = 0.966KN/m2
Now, as per Table no.7 IS 875(3): 2015, for tilt angle of 20°,
Downward Wind Coefficient Cpd = 0.80
Upward Wind Coefficient Cpu = -1.30
Figure 4-1: Sectional View of MMS under consideration
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 5 of 11
Old Method: - Uniform Wind Loading Updated Method: - Eccentric Wind Loading
CASE 1: - Downward Wind force
In this case, the pressure is distributed uniformly over
the panels as shown in the figure above. The centre of
pressure lies exactly at the Centre of the two panels as
shown.
Total Force (per unit width),
Ftotal = Cpd x A x Pz
Ftotal = 0.80 x (4.236 x 1) x 0.966
Ftotal = 3.273 KN per unit width
CASE 1: - Downward Wind force
In this case, the pressure is distributed uniformly in two
parts having intensities 1.8Pz and 0.2Pz as shown in the
figure to assure that the Centre of pressure is acting at
0.3W.
C.G Calculation: -
Distance of CP = P1 x X1 + P2 x X2 / (P1 + P2)
= (1.8 Pz x 1059 + 0.2 Pz x 3177) / 2.0Pz
= 1270.8
And, 1270.8/4236 = 0.3
Thus the Centre of Pressure acts at 0.3W
Total Force (per unit width),
Ftotal = F1total + F2total
Ftotal = 0.80 x (2.118 x 1) x 1.8 x 0.966 + 0.80 x (2.118 x
1) x 0.2 x 0.966
Ftotal = 2.946 + 0.327
Ftotal = 3.273 KN per unit width
Thus, the total force coming on the entire assembly shall be same in both the cases; only the distribution of
this force on the purlins will be different, which is presented in the below section.
Load distribution on Purlins: - The total force as
calculated above is equally distributed on all the four
purlins as shown in the figure below
Load distribution on Purlins: - The force distribution
on the purlins is as per the pressure distribution on the
respective panels. The purlins lying in the high pressure
region will have higher forces and vice versa.
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 6 of 11
F = 3.273 / 4
F = 0.818 KN/m
F1 = F1total / 2 = 2.946 / 2
F1 = 1.473 KN/m
F2 = F2total / 2 = 0.327 / 2
F2 = 0.164 KN/m
CASE 2: - Upward Wind force
The upward wind forces will be calculated in similar
fashion by using upward wind pressure coefficients.
Total Force (per unit width),
Ftotal = Cpu x A x Pz
Ftotal = -1.3 x (4.236 x 1) x 0.966
Ftotal = 5.320 KN per unit width
F = 5.320 / 4
F = 1.330 KN/m
CASE 2: - Upward Wind force
The upward wind forces will be calculated in similar
fashion by using upward wind pressure coefficients.
Total Force (per unit width),
Ftotal = F1total + F2total
Ftotal = 1.3 x (2.118 x 1) x 0.2 x 0.966 + 1.3 x (2.118 x 1)
x 1.8 x 0.966
Ftotal = 0.532 + 4.787
Ftotal = 5.320 KN per unit width
F1 = F1total / 2 = 0.532 / 2
F1 = 0.266 KN/m
F2 = F2total / 2 = 4.787 / 2
F2 = 2.393 KN/m
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 7 of 11
ANALYTICAL STUDY
In this study, static analysis of the Module mounting structure is carried out in Staad Pro for uniform as well as
eccentric loading calculated in the above sections. The sectional view of the Staad model is provided below:
Uniform loading applied on purlins:
Wind Upward Case: -
Wind Downward Case: -
Eccentric loading applied on purlins:
Wind Upward Case: -
Wind Downward Case: -
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 8 of 11
Check for Deflection:
Deflections of the structural elements of the MMS based on the worst load combination shall be limited to an
acceptable level. The deflections obtained are provided below:
Member Section size
Span
(mm)
Deflection
Criteria
Allowable
Deflection
(mm)
Uniform
Loading
(mm)
Eccentric
Loading
(mm)
Remarks
Column Post 150CS50x3.15 1242 L/150 8.28 6.71 19.60 Deflection
exceeds the
permissible
limits in
Eccentric
Loading
Rafter
Cantilever
Top
70CS50x1.5x10 1642 L/150 10.94 7.24 27.82
Rafter
Cantilever
Bottom
70CS50x1.5x10 1642 L/150 10.94 8.85 28.79
Central Purlin 90HU40x25x0.8 3150 L/180 17.50 5.53 10.72 Safe
End Purlin 90HU40x25x0.8 3150 L/180 17.50 4.88 10.84 Safe
Purlin
Cantilever
90HU40x25x0.8 1000 L/180 5.55 0.07 4.22 Safe
The deflections for the MMS members are within the permissible limits for uniform loading. However, the
deflections in column post and rafters exceed the permissible limit for eccentric wind loading. The deflections
observed for eccentric loading almost three times of that observed for uniform loading.
Check for Forces:
A major increase is observed in the Bending moment of the columns due to application of eccentric wind loading
which can be verified from the below provided figures:
B.M (Uniform Loading) = 6.578KN.m B.M (Eccentric Loading) = 19.712KN.m
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 9 of 11
In case of eccentric loading, the wind forces act predominantly on the half part of the canopy as seen in the above
load calculations. Hence, a tremendous increase is observed in the moments generated in the columns. The moment
due to lateral wind forces under eccentric loading is around three times of the moment in column under uniform
loading.
Check for Utilisation Ratios:
The utilisation ratios of the members of MMS under uniform and eccentric loading are provided in the table below:
Member Section Size
Utilisation Ratio for
Uniform Loading
Utilisation Ratio for
Eccentric Loading
Column Post 150CS50x3.15 0.7 to 0.8 2.0 to 2.2
Rafter 70CS50x1.5x10 0.5 to 0.6 1.1 to 1.2
Purlin 90HU40x25x0.8 0.8 to 0.9 0.9 to 1.5
Bracing 60CS50x1.6x10 0.5 to 0.7 0.3 to 0.5
The utilisation ratios of the column posts, rafters and purlins are greater than 1 for eccentric loading, indicating
failure of these members with stresses exceeding the permissible limits. Now, the sections sizes are revised to
maintain the utilisation ratios (stresses) and deflections within the permissible range and similar to that obtained in
uniform loading. The revised section sizes required for eccentric loading are as presented below:
Member
Section sizes for Uniform
Loading
Section sizes for
Eccentric Loading
Remarks
Column Post 150CS50x3.15 250CS50x3.15 Deflections and utilisation
ratios observed for both
the types of loading are in
the same range and limits.
Rafter 70CS50x1.5x10 100CS40x1.6x10
Purlin 90HU40x25x0.8 90HU40x25x1.0
Bracing 60CS50x1.6x10 60CS50x1.6x10
Tonnage per Table 456.02kg 556.96kg
Thus, the tonnage increment of around 22% is required for the MMS to sustain the eccentric wind loading.
*Disclaimer: The above mentioned section sizes are utilised only for the purpose of sample case study. SgurrEnergy does not promote use of same sections and
suggests using design specific member sizes.
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 10 of 11
5 Reference to International Design Standards
A limited research on the International design codes in the direction of application of wind loading
on Monopitch canopies clearly validate the application of eccentric wind loading. The references
are as provided below:
5.1 American Codes (ASCE 7-16)
Figure 5-1: Diagram 27.3-4 of ASCE 7-16 providing pressure coefficients for Monoslope roof
5.2 Euro Code
Figure 5-2: Diagram 7.16 – Location of the centre of force for Monopitch canopies
Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 11 of 11
6 Conclusion: SgurrEnergy Recommended Approach
SgurrEnergy has more than 13 years of experience in the design of Module mounting structures for
large scale solar PV plants. The Structural Engineering department at SgurrEnergy is involved in
continuous research and development for accurate estimation of wind load and studying the
behaviour of the mounting structures under such loads.
The Structural design team endorses application of eccentric distribution of wind load as per IS
875(Part 3) for design of the mounting structures and also acquaint the clients about the possible
consequences of ignoring the Codal provisions in the design of the structures.
Following upon the case study presented in this technical paper on application of wind loading,
SgurrEnergy herein recommends design approach summarised as below:
• The pressure distribution on the modules is not uniform and there is variation in the
pressure applied on the PV modules. This can be attributed to the note no.1 with Table 8
of IS 875 (Part 3):2015 which clearly states that the centre of pressure shall act at 0.3w.
This note is usually ignored by the designers leading to inaccurate design assumptions.
• The variation in pressure distribution on the PV modules validated by the study of the
International design codes indicates that the pressure applied on the entire monopitch
canopy is not same throughout but different based on pressure coefficients.
• The total force coming on the entire assembly / canopy is same in both the cases – uniform
and eccentric loading, only the distribution of force is different on purlins for eccentric
loading. A detailed methodology and sample study to prove the same is provided in the
above chapters.
• Application of eccentric loading on MMS designed for uniform causes the deflections in
column post and rafters to increase by approximately three times as compared to the
deflections obtained for uniform loading. Also, the utilisation ratios (stresses) for the
column posts and rafters get approximately doubled in comparison to the stresses
developed in case of uniform loading.
• The concentration of load on one side of canopy in eccentric wind loading causes increase
in the bending moment of column post by around three times. As a result, the deflections
and stresses obtained are higher as stated in the point above.
• Based on the above sample study, an increase of around 22% in tonnage may be expected
for MMS designed for uniform wind loading to sustain eccentric wind loading.
• The findings and conclusions presented in this article is based on the specific sample input
consideration. SgurrEnergy recommends carrying project specific study based on the above
mentioned approach.
7 References:
1. IS 875 (Part 3): 2015: - Design Loads (other than Earthquake) for Buildings and Structures
– Code of Practise. Part 3 – Wind Loads Third Revision.
2. ASCE 7 -16: - Minimum Design Loads for Buildings and Other Structures.
3. EN.1994.1.4.2005: - Eurocode 1: Actions on structures - Part 1-4: General actions - Wind
actions [Authority: The European Union Per Regulation 305/2011, Directive 98/34/EC,
Directive 2004/18/EC].
4. “Wind Loads on Utility Scale Solar PV Power Plants” by Joseph H. Cain – 2015 SEAOC
Convention Proceedings.
5. “Wind Load Design of PV Power Plants by Comparison of Design codes and Wind Tunnel
Tests.” by O. Bogdan and D. Cretu – Mathematical Modelling in Civil Engineering (Vol.15
– No.3: 13-27-2019).

More Related Content

What's hot

Design, Analysis and Testing of Wing Spar for Optimum Weight
Design, Analysis and Testing of Wing Spar for Optimum WeightDesign, Analysis and Testing of Wing Spar for Optimum Weight
Design, Analysis and Testing of Wing Spar for Optimum Weight
RSIS International
 
Comparative study of four legged self supported angular telecommunication tow...
Comparative study of four legged self supported angular telecommunication tow...Comparative study of four legged self supported angular telecommunication tow...
Comparative study of four legged self supported angular telecommunication tow...
eSAT Journals
 

What's hot (20)

Unit iv - Rockets and Misiles
Unit iv - Rockets and MisilesUnit iv - Rockets and Misiles
Unit iv - Rockets and Misiles
 
The types of Wing
The types of WingThe types of Wing
The types of Wing
 
Aircraft configuration
Aircraft configurationAircraft configuration
Aircraft configuration
 
CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2
CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2
CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2
 
Design, Analysis and Testing of Wing Spar for Optimum Weight
Design, Analysis and Testing of Wing Spar for Optimum WeightDesign, Analysis and Testing of Wing Spar for Optimum Weight
Design, Analysis and Testing of Wing Spar for Optimum Weight
 
Surface Structures, including SAP2000
Surface Structures, including SAP2000Surface Structures, including SAP2000
Surface Structures, including SAP2000
 
Free standing stair
Free standing stairFree standing stair
Free standing stair
 
Steel Design to AS4100 1998 (+A1,2016) Webinar - ClearCalcs
Steel Design to AS4100 1998 (+A1,2016) Webinar - ClearCalcsSteel Design to AS4100 1998 (+A1,2016) Webinar - ClearCalcs
Steel Design to AS4100 1998 (+A1,2016) Webinar - ClearCalcs
 
Hands on experience with various type of tabs
Hands on experience with various type of tabsHands on experience with various type of tabs
Hands on experience with various type of tabs
 
Design and analysis of wing for Unmanned Aerial Vehicle using CFD
Design and analysis of wing for Unmanned Aerial Vehicle using CFDDesign and analysis of wing for Unmanned Aerial Vehicle using CFD
Design and analysis of wing for Unmanned Aerial Vehicle using CFD
 
Etabs modeling - Design of slab according to EC2
Etabs modeling  - Design of slab according to EC2Etabs modeling  - Design of slab according to EC2
Etabs modeling - Design of slab according to EC2
 
Wind Load of Wind Turbine Tower
Wind Load of Wind Turbine TowerWind Load of Wind Turbine Tower
Wind Load of Wind Turbine Tower
 
WIND LOAD ON BUILDING AND STR.pdf
WIND LOAD ON BUILDING AND STR.pdfWIND LOAD ON BUILDING AND STR.pdf
WIND LOAD ON BUILDING AND STR.pdf
 
Comparative study of four legged self supported angular telecommunication tow...
Comparative study of four legged self supported angular telecommunication tow...Comparative study of four legged self supported angular telecommunication tow...
Comparative study of four legged self supported angular telecommunication tow...
 
Stress and fatigue analysis of landing gear axle of a trainer aircraft
Stress and fatigue analysis of landing gear axle of a trainer aircraftStress and fatigue analysis of landing gear axle of a trainer aircraft
Stress and fatigue analysis of landing gear axle of a trainer aircraft
 
Special shear walls + ordinary shear walls ACI - 318 - جدران القص الخاصة - P...
Special shear walls + ordinary  shear walls ACI - 318 - جدران القص الخاصة - P...Special shear walls + ordinary  shear walls ACI - 318 - جدران القص الخاصة - P...
Special shear walls + ordinary shear walls ACI - 318 - جدران القص الخاصة - P...
 
Aircraft wing
Aircraft wingAircraft wing
Aircraft wing
 
Tutorial #1 - SACS Basic
Tutorial #1 - SACS BasicTutorial #1 - SACS Basic
Tutorial #1 - SACS Basic
 
89505650 concrete-beam-and-slab-design-using-prokon
89505650 concrete-beam-and-slab-design-using-prokon89505650 concrete-beam-and-slab-design-using-prokon
89505650 concrete-beam-and-slab-design-using-prokon
 
Ch4 Bridge Floors (Steel Bridges تصميم الكباري المعدنية & Prof. Dr. Metwally ...
Ch4 Bridge Floors (Steel Bridges تصميم الكباري المعدنية & Prof. Dr. Metwally ...Ch4 Bridge Floors (Steel Bridges تصميم الكباري المعدنية & Prof. Dr. Metwally ...
Ch4 Bridge Floors (Steel Bridges تصميم الكباري المعدنية & Prof. Dr. Metwally ...
 

Similar to Importance of Eccentric Wind Loading on Monopitch Module Mounting Structures

Similar to Importance of Eccentric Wind Loading on Monopitch Module Mounting Structures (20)

IRJET- Effective Control of Response of a Building Under Wind Vibration using...
IRJET- Effective Control of Response of a Building Under Wind Vibration using...IRJET- Effective Control of Response of a Building Under Wind Vibration using...
IRJET- Effective Control of Response of a Building Under Wind Vibration using...
 
COMPARISON BETWEEN VARIOUS STEEL SECTION BY USING IS CODE AND EURO CODE
COMPARISON BETWEEN VARIOUS STEEL SECTION BY USING IS CODE AND EURO CODECOMPARISON BETWEEN VARIOUS STEEL SECTION BY USING IS CODE AND EURO CODE
COMPARISON BETWEEN VARIOUS STEEL SECTION BY USING IS CODE AND EURO CODE
 
Numerical Prediction of the Effect of Cyclonic Wind Pressures on the Solar Pa...
Numerical Prediction of the Effect of Cyclonic Wind Pressures on the Solar Pa...Numerical Prediction of the Effect of Cyclonic Wind Pressures on the Solar Pa...
Numerical Prediction of the Effect of Cyclonic Wind Pressures on the Solar Pa...
 
CFD Analysis for Computing Drag force on Various types of blades for Vertical...
CFD Analysis for Computing Drag force on Various types of blades for Vertical...CFD Analysis for Computing Drag force on Various types of blades for Vertical...
CFD Analysis for Computing Drag force on Various types of blades for Vertical...
 
Chimney design &engg code
Chimney design &engg codeChimney design &engg code
Chimney design &engg code
 
Blast Resistant Buildings
Blast Resistant BuildingsBlast Resistant Buildings
Blast Resistant Buildings
 
FE Analysis of Bolted Connections for Wind Turbine Towers by Yadneshwar S. Joshi
FE Analysis of Bolted Connections for Wind Turbine Towers by Yadneshwar S. JoshiFE Analysis of Bolted Connections for Wind Turbine Towers by Yadneshwar S. Joshi
FE Analysis of Bolted Connections for Wind Turbine Towers by Yadneshwar S. Joshi
 
IRJET- Wind Load Analysis for Different Configuration of Structures
IRJET- Wind Load Analysis for Different Configuration of StructuresIRJET- Wind Load Analysis for Different Configuration of Structures
IRJET- Wind Load Analysis for Different Configuration of Structures
 
Reduction of Vibrations in a Vertical Axis Wind Turbine using Blade Design Mo...
Reduction of Vibrations in a Vertical Axis Wind Turbine using Blade Design Mo...Reduction of Vibrations in a Vertical Axis Wind Turbine using Blade Design Mo...
Reduction of Vibrations in a Vertical Axis Wind Turbine using Blade Design Mo...
 
Design of dual axis tracker wps
Design of dual axis tracker wpsDesign of dual axis tracker wps
Design of dual axis tracker wps
 
Wind farm optimal_design_including_risk
Wind farm optimal_design_including_riskWind farm optimal_design_including_risk
Wind farm optimal_design_including_risk
 
Failure Analysis of Composite Windshield
Failure Analysis of Composite WindshieldFailure Analysis of Composite Windshield
Failure Analysis of Composite Windshield
 
IRJET- Codal Comparison of IS-875 (Part 3) 1987 and IS-875 (Part 3) 2015 for ...
IRJET- Codal Comparison of IS-875 (Part 3) 1987 and IS-875 (Part 3) 2015 for ...IRJET- Codal Comparison of IS-875 (Part 3) 1987 and IS-875 (Part 3) 2015 for ...
IRJET- Codal Comparison of IS-875 (Part 3) 1987 and IS-875 (Part 3) 2015 for ...
 
Parametric Study for Wind Design of Vertical Pressure Vessel as per Indian St...
Parametric Study for Wind Design of Vertical Pressure Vessel as per Indian St...Parametric Study for Wind Design of Vertical Pressure Vessel as per Indian St...
Parametric Study for Wind Design of Vertical Pressure Vessel as per Indian St...
 
Dynamic Wind Analysis of High-Rise Building
Dynamic Wind Analysis of High-Rise BuildingDynamic Wind Analysis of High-Rise Building
Dynamic Wind Analysis of High-Rise Building
 
Study of Viscous Fluid Damper 6 Different Pattern on 12 Story Structure And C...
Study of Viscous Fluid Damper 6 Different Pattern on 12 Story Structure And C...Study of Viscous Fluid Damper 6 Different Pattern on 12 Story Structure And C...
Study of Viscous Fluid Damper 6 Different Pattern on 12 Story Structure And C...
 
IRJET- Design and Finite Element Analysis(FEA) of Formula Student Chassis
IRJET- Design and Finite Element Analysis(FEA) of Formula Student ChassisIRJET- Design and Finite Element Analysis(FEA) of Formula Student Chassis
IRJET- Design and Finite Element Analysis(FEA) of Formula Student Chassis
 
Design of manual solar tracking system wps
Design of manual solar tracking system wpsDesign of manual solar tracking system wps
Design of manual solar tracking system wps
 
Design and Fabrication of Bladeless Wind Power Generation
Design and Fabrication of Bladeless Wind Power GenerationDesign and Fabrication of Bladeless Wind Power Generation
Design and Fabrication of Bladeless Wind Power Generation
 
IRJET- Manufacturing System of Hybrid Vertical Axis Wind Turbine
IRJET- Manufacturing System of Hybrid Vertical Axis Wind TurbineIRJET- Manufacturing System of Hybrid Vertical Axis Wind Turbine
IRJET- Manufacturing System of Hybrid Vertical Axis Wind Turbine
 

More from SgurrEnergy Pvt. Ltd.

More from SgurrEnergy Pvt. Ltd. (6)

Bifacial PV Modules- SgurrEnergy
Bifacial PV Modules- SgurrEnergyBifacial PV Modules- SgurrEnergy
Bifacial PV Modules- SgurrEnergy
 
Solar PV Module in India - SgurrEnergy
Solar PV Module in India - SgurrEnergySolar PV Module in India - SgurrEnergy
Solar PV Module in India - SgurrEnergy
 
Solar Engineering Consultants- SgurrEnergy
Solar Engineering Consultants- SgurrEnergySolar Engineering Consultants- SgurrEnergy
Solar Engineering Consultants- SgurrEnergy
 
Power Plant Controller-Putting the Power back into the hands of the Developer
Power Plant Controller-Putting the Power back into the hands of the DeveloperPower Plant Controller-Putting the Power back into the hands of the Developer
Power Plant Controller-Putting the Power back into the hands of the Developer
 
Flood Risk Assessment - SgurrEnergy
Flood Risk Assessment - SgurrEnergyFlood Risk Assessment - SgurrEnergy
Flood Risk Assessment - SgurrEnergy
 
Battery Energy Storage, Technology and Applications
Battery Energy Storage, Technology and ApplicationsBattery Energy Storage, Technology and Applications
Battery Energy Storage, Technology and Applications
 

Recently uploaded

Insurers' journeys to build a mastery in the IoT usage
Insurers' journeys to build a mastery in the IoT usageInsurers' journeys to build a mastery in the IoT usage
Insurers' journeys to build a mastery in the IoT usage
Matteo Carbone
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
amitlee9823
 
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pillsMifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Abortion pills in Kuwait Cytotec pills in Kuwait
 

Recently uploaded (20)

Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best ServicesMysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
 
Insurers' journeys to build a mastery in the IoT usage
Insurers' journeys to build a mastery in the IoT usageInsurers' journeys to build a mastery in the IoT usage
Insurers' journeys to build a mastery in the IoT usage
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
 
The Coffee Bean & Tea Leaf(CBTL), Business strategy case study
The Coffee Bean & Tea Leaf(CBTL), Business strategy case studyThe Coffee Bean & Tea Leaf(CBTL), Business strategy case study
The Coffee Bean & Tea Leaf(CBTL), Business strategy case study
 
Monte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMMonte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSM
 
John Halpern sued for sexual assault.pdf
John Halpern sued for sexual assault.pdfJohn Halpern sued for sexual assault.pdf
John Halpern sued for sexual assault.pdf
 
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
 
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
 
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
 
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
 
Monthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxMonthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptx
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communications
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
 
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfDr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
 
HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael Hawkins
 
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
 
Famous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st CenturyFamous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st Century
 
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pillsMifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
 
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
 

Importance of Eccentric Wind Loading on Monopitch Module Mounting Structures

  • 1.
  • 2. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 1 of 11 1 Abstract Wind load governs the design of the mounting structures of solar panels which constitute approximately 10 to 15 percent of the total project cost. Wind load design of the ground-mounted photovoltaic (PV) power plants requires interpretation of the design code considering the particularities of these structures. Structural failures of utility scale PV plants are rare events, but some failures have still been observed in code-compliant structures. Wind loads are calculated using the static pressure coefficients provided in national as well as international design standards. In the Indian Solar industry, the wind loads are applied uniformly over the entire panel, acting as monoslope canopy, based on older version of IS875: Part 3. This paper demonstrates that this is not a precise method of wind load application and; provides a detailed description of eccentrically distributed wind load application based on IS 875: Part 3 (2015) and various other international design codes. 2 Introduction Over last decade, solar PV industry has endured remarkable advancement in terms of both efficiency and cost reduction. PV module is the key component of a solar PV plant, however it should be noted that the module mounting structure plays an equally critical role in reliability and durability of solar PV plants that have designed life of more than 25 years. The falling tariff trend has posed pressure on balance of system (BoS) cost and module mounting structure is most sought after plant equipment which are being compromised in order to cut down the cost of the project. This is usually done by reducing the section sizes of the supporting module mounting structure. The prospect of reducing the overall project cost is good, however as per SgurrEnergy’s experience the focus has been on reducing the weight of the structure while the strength of the structure to sustain the gust of wind are being compromised. Focusing on the evidences from India, there have been numerous incidences of MMS failures at lower wind speed. Structural failures have been observed in code-compliant ground-mounted systems during wind events at wind speeds significantly less than design wind speed. The current industrial research has been focused on determining the cause of failure in otherwise code-compliant structures and improving correct method of application of wind loads. Figure 2-1: Failure of the complete Module Mounting table under wind loading Source: www.rmi.org
  • 3. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 2 of 11 Figure 2-2: Failure of the part of Module Mounting Structure under wind loading Source: pv-magazine-usa.com Application of wind load governs the design of the module mounting structure. Due to lack of solar specific design code, most designers typically follow the design procedures recommended by building codes meant for large sloped roofs. This may lead to inappropriate and inaccurate results leading to unsafe designs. Though, the current wind design standards have a very wide scale of applications, they do not cover solar specific wind design guidelines. Through this paper SgurrEnergy intends to presents the precise and specific method of application of wind loading on the mounting structure with reference to explicit notes provided in the Indian design standards and international standards. 3 Eccentric Wind Loading – A Technical Investigation Several designs elements are required to be considered during MMS design. Application of wind load is one such important element which is generally compromised. The current industry trend of MMS design is to assume wind pressure acting uniformly over the entire solar panel, such that the force acts at the centre of the distributed area as shown in the figure below. Figure 3-1: Uniform Wind load distribution Here, w= Length of entire assembly/ canopy. SgurrEnergy would like to call/draw attention to the note provided below the Table 8 of IS 875 (Part 3): 2015 states that the wind load shall be applied in such a way that the centre of pressure
  • 4. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 3 of 11 shall act at 0.3w from windward edge and not at the centre of entire assembly (0.5w). Furthermore, Table 8 of IS 875 (Part 3): 2015 provides the pressure coefficients for mono-slope free roofs. As illustrated in figure below, code also provides the method of application of load. The note number 1 implies that the load application on mono-pitch canopies shall not be uniformly distributed load. The pressure/load shall act eccentrically on surface. Figure below illustrates the load application in accordance with the code requirements. Figure 3-2: Eccentric Wind load distribution 4 Methodology and Sample Study In this part of the paper, SgurrEnergy intends to explicate the procedure to calculate forces on purlins of the module mounting structures for uniform and eccentric wind loading through a case study. Case Study: The description of the MMS under consideration is as follows, The Table configuration is 2Px30 and the fixed tilt is 20°. The Module size 2108mm x 1048mm x 40mm having weight 24.9kg separated by distance of 20mm. The structure lies in the region of basic wind speed 47m/s. As per IS 875 (3): 2015,
  • 5. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 4 of 11 Design wind speed Vz = K1 K2 K3 K4 Vb Basic wind speed Vb = 47m/s Risk coefficient K1 = 0.9 Terrain, height and structure size factor K2 = 1.0 Topography factor K3 = 1.0 Importance factor K4 = 1.0 Hence, Vz = 42.30m/s Basic Wind Pressure Pd = 0.6 Vz2 Pd = 1.074KN/m2 Design Wind pressure Pz = Kd Ka Kc Pd Wind directionality factor Kd = 0.9 Area averaging factor Ka = 1.0 Combination factor Kc = 1.0 Hence, Pz = 0.966KN/m2 Now, as per Table no.7 IS 875(3): 2015, for tilt angle of 20°, Downward Wind Coefficient Cpd = 0.80 Upward Wind Coefficient Cpu = -1.30 Figure 4-1: Sectional View of MMS under consideration
  • 6. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 5 of 11 Old Method: - Uniform Wind Loading Updated Method: - Eccentric Wind Loading CASE 1: - Downward Wind force In this case, the pressure is distributed uniformly over the panels as shown in the figure above. The centre of pressure lies exactly at the Centre of the two panels as shown. Total Force (per unit width), Ftotal = Cpd x A x Pz Ftotal = 0.80 x (4.236 x 1) x 0.966 Ftotal = 3.273 KN per unit width CASE 1: - Downward Wind force In this case, the pressure is distributed uniformly in two parts having intensities 1.8Pz and 0.2Pz as shown in the figure to assure that the Centre of pressure is acting at 0.3W. C.G Calculation: - Distance of CP = P1 x X1 + P2 x X2 / (P1 + P2) = (1.8 Pz x 1059 + 0.2 Pz x 3177) / 2.0Pz = 1270.8 And, 1270.8/4236 = 0.3 Thus the Centre of Pressure acts at 0.3W Total Force (per unit width), Ftotal = F1total + F2total Ftotal = 0.80 x (2.118 x 1) x 1.8 x 0.966 + 0.80 x (2.118 x 1) x 0.2 x 0.966 Ftotal = 2.946 + 0.327 Ftotal = 3.273 KN per unit width Thus, the total force coming on the entire assembly shall be same in both the cases; only the distribution of this force on the purlins will be different, which is presented in the below section. Load distribution on Purlins: - The total force as calculated above is equally distributed on all the four purlins as shown in the figure below Load distribution on Purlins: - The force distribution on the purlins is as per the pressure distribution on the respective panels. The purlins lying in the high pressure region will have higher forces and vice versa.
  • 7. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 6 of 11 F = 3.273 / 4 F = 0.818 KN/m F1 = F1total / 2 = 2.946 / 2 F1 = 1.473 KN/m F2 = F2total / 2 = 0.327 / 2 F2 = 0.164 KN/m CASE 2: - Upward Wind force The upward wind forces will be calculated in similar fashion by using upward wind pressure coefficients. Total Force (per unit width), Ftotal = Cpu x A x Pz Ftotal = -1.3 x (4.236 x 1) x 0.966 Ftotal = 5.320 KN per unit width F = 5.320 / 4 F = 1.330 KN/m CASE 2: - Upward Wind force The upward wind forces will be calculated in similar fashion by using upward wind pressure coefficients. Total Force (per unit width), Ftotal = F1total + F2total Ftotal = 1.3 x (2.118 x 1) x 0.2 x 0.966 + 1.3 x (2.118 x 1) x 1.8 x 0.966 Ftotal = 0.532 + 4.787 Ftotal = 5.320 KN per unit width F1 = F1total / 2 = 0.532 / 2 F1 = 0.266 KN/m F2 = F2total / 2 = 4.787 / 2 F2 = 2.393 KN/m
  • 8. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 7 of 11 ANALYTICAL STUDY In this study, static analysis of the Module mounting structure is carried out in Staad Pro for uniform as well as eccentric loading calculated in the above sections. The sectional view of the Staad model is provided below: Uniform loading applied on purlins: Wind Upward Case: - Wind Downward Case: - Eccentric loading applied on purlins: Wind Upward Case: - Wind Downward Case: -
  • 9. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 8 of 11 Check for Deflection: Deflections of the structural elements of the MMS based on the worst load combination shall be limited to an acceptable level. The deflections obtained are provided below: Member Section size Span (mm) Deflection Criteria Allowable Deflection (mm) Uniform Loading (mm) Eccentric Loading (mm) Remarks Column Post 150CS50x3.15 1242 L/150 8.28 6.71 19.60 Deflection exceeds the permissible limits in Eccentric Loading Rafter Cantilever Top 70CS50x1.5x10 1642 L/150 10.94 7.24 27.82 Rafter Cantilever Bottom 70CS50x1.5x10 1642 L/150 10.94 8.85 28.79 Central Purlin 90HU40x25x0.8 3150 L/180 17.50 5.53 10.72 Safe End Purlin 90HU40x25x0.8 3150 L/180 17.50 4.88 10.84 Safe Purlin Cantilever 90HU40x25x0.8 1000 L/180 5.55 0.07 4.22 Safe The deflections for the MMS members are within the permissible limits for uniform loading. However, the deflections in column post and rafters exceed the permissible limit for eccentric wind loading. The deflections observed for eccentric loading almost three times of that observed for uniform loading. Check for Forces: A major increase is observed in the Bending moment of the columns due to application of eccentric wind loading which can be verified from the below provided figures: B.M (Uniform Loading) = 6.578KN.m B.M (Eccentric Loading) = 19.712KN.m
  • 10. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 9 of 11 In case of eccentric loading, the wind forces act predominantly on the half part of the canopy as seen in the above load calculations. Hence, a tremendous increase is observed in the moments generated in the columns. The moment due to lateral wind forces under eccentric loading is around three times of the moment in column under uniform loading. Check for Utilisation Ratios: The utilisation ratios of the members of MMS under uniform and eccentric loading are provided in the table below: Member Section Size Utilisation Ratio for Uniform Loading Utilisation Ratio for Eccentric Loading Column Post 150CS50x3.15 0.7 to 0.8 2.0 to 2.2 Rafter 70CS50x1.5x10 0.5 to 0.6 1.1 to 1.2 Purlin 90HU40x25x0.8 0.8 to 0.9 0.9 to 1.5 Bracing 60CS50x1.6x10 0.5 to 0.7 0.3 to 0.5 The utilisation ratios of the column posts, rafters and purlins are greater than 1 for eccentric loading, indicating failure of these members with stresses exceeding the permissible limits. Now, the sections sizes are revised to maintain the utilisation ratios (stresses) and deflections within the permissible range and similar to that obtained in uniform loading. The revised section sizes required for eccentric loading are as presented below: Member Section sizes for Uniform Loading Section sizes for Eccentric Loading Remarks Column Post 150CS50x3.15 250CS50x3.15 Deflections and utilisation ratios observed for both the types of loading are in the same range and limits. Rafter 70CS50x1.5x10 100CS40x1.6x10 Purlin 90HU40x25x0.8 90HU40x25x1.0 Bracing 60CS50x1.6x10 60CS50x1.6x10 Tonnage per Table 456.02kg 556.96kg Thus, the tonnage increment of around 22% is required for the MMS to sustain the eccentric wind loading. *Disclaimer: The above mentioned section sizes are utilised only for the purpose of sample case study. SgurrEnergy does not promote use of same sections and suggests using design specific member sizes.
  • 11. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 10 of 11 5 Reference to International Design Standards A limited research on the International design codes in the direction of application of wind loading on Monopitch canopies clearly validate the application of eccentric wind loading. The references are as provided below: 5.1 American Codes (ASCE 7-16) Figure 5-1: Diagram 27.3-4 of ASCE 7-16 providing pressure coefficients for Monoslope roof 5.2 Euro Code Figure 5-2: Diagram 7.16 – Location of the centre of force for Monopitch canopies
  • 12. Certified to ISO 14001:2015, 45001:2018 and 9001:2015 Page 11 of 11 6 Conclusion: SgurrEnergy Recommended Approach SgurrEnergy has more than 13 years of experience in the design of Module mounting structures for large scale solar PV plants. The Structural Engineering department at SgurrEnergy is involved in continuous research and development for accurate estimation of wind load and studying the behaviour of the mounting structures under such loads. The Structural design team endorses application of eccentric distribution of wind load as per IS 875(Part 3) for design of the mounting structures and also acquaint the clients about the possible consequences of ignoring the Codal provisions in the design of the structures. Following upon the case study presented in this technical paper on application of wind loading, SgurrEnergy herein recommends design approach summarised as below: • The pressure distribution on the modules is not uniform and there is variation in the pressure applied on the PV modules. This can be attributed to the note no.1 with Table 8 of IS 875 (Part 3):2015 which clearly states that the centre of pressure shall act at 0.3w. This note is usually ignored by the designers leading to inaccurate design assumptions. • The variation in pressure distribution on the PV modules validated by the study of the International design codes indicates that the pressure applied on the entire monopitch canopy is not same throughout but different based on pressure coefficients. • The total force coming on the entire assembly / canopy is same in both the cases – uniform and eccentric loading, only the distribution of force is different on purlins for eccentric loading. A detailed methodology and sample study to prove the same is provided in the above chapters. • Application of eccentric loading on MMS designed for uniform causes the deflections in column post and rafters to increase by approximately three times as compared to the deflections obtained for uniform loading. Also, the utilisation ratios (stresses) for the column posts and rafters get approximately doubled in comparison to the stresses developed in case of uniform loading. • The concentration of load on one side of canopy in eccentric wind loading causes increase in the bending moment of column post by around three times. As a result, the deflections and stresses obtained are higher as stated in the point above. • Based on the above sample study, an increase of around 22% in tonnage may be expected for MMS designed for uniform wind loading to sustain eccentric wind loading. • The findings and conclusions presented in this article is based on the specific sample input consideration. SgurrEnergy recommends carrying project specific study based on the above mentioned approach. 7 References: 1. IS 875 (Part 3): 2015: - Design Loads (other than Earthquake) for Buildings and Structures – Code of Practise. Part 3 – Wind Loads Third Revision. 2. ASCE 7 -16: - Minimum Design Loads for Buildings and Other Structures. 3. EN.1994.1.4.2005: - Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions [Authority: The European Union Per Regulation 305/2011, Directive 98/34/EC, Directive 2004/18/EC]. 4. “Wind Loads on Utility Scale Solar PV Power Plants” by Joseph H. Cain – 2015 SEAOC Convention Proceedings. 5. “Wind Load Design of PV Power Plants by Comparison of Design codes and Wind Tunnel Tests.” by O. Bogdan and D. Cretu – Mathematical Modelling in Civil Engineering (Vol.15 – No.3: 13-27-2019).