SlideShare a Scribd company logo
1 of 354
Download to read offline
Delixi Electric: Who are we
A global company at your service
A reliable company serving you with reliable product
Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM€,employing more than 15000 people.
Delixi created an international Joint Venture in November 2007,named Delixi Electric Ltd., in order to serve you
worldwide,with core LV products having the right quality at the right price.
Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric
employs 5200 people world wide.
Dedicated R&D center
International quality control of suppliers
International quality control of plants
Fully automatized distribution center
Network of recognized 600 distributors
world wide
Reliable Quality
For more details, please contact your local Delixi Electric Company.
I
046-050
051-055
056-057
058-062
002-029
030-045
Contents
Final Distribution
Miniature Circuit Breaker & Switch Disconnectors
Residual Current Devices
Accessories for MCB&RCBO
Control Devices
Surge Protective Device
Distribution Box
CDB6 18mm Miniature Circuit Breaker 002
CDB6s 18mm Miniature Circuit Breaker 007
CDB9 18mm Miniature Circuit Breaker 011
CDB2 27mm Miniature Circuit Breaker 016
CDB6p Phase-neutral Circuit Breaker 019
CDB3 Phase-neutral Circuit Breaker 021
CDB6IS Switch Disconnector 023
CDB5 Switch Disconnector 025
CDG9 Switch Disconnector 027
CDB6LE Residual Current Operated Circuit Breaker 030
CDB6v Residual Current Protection Module 033
CDB2LE Residual Current Operated Circuit Breaker 036
CDB6pLE Residual Current Operated Circuit Breaker 039
CDB3LE Residual Current Operated Circuit Breaker 041
CDL6SP Residual Current Operated Circuit Breaker 043
CDB6VR Electromagnetic Type Residual Current Switch 044
SD,OF,MX+OF 046
Busbar 050
CDCH8P Modular Contactor 051
CDRT8 Time Relay 054
CDPZ50 Series Consumer Box 058
JXF Metal Enclosure 060
CDY1 Surge Protective Device 056
II
120-193
063-119
194-245
246-247
248-257
Low-voltage Distribution
Motor Control & Protection
Molded Case Circuit Breaker
Air Circuit Breaker
Contactor&Thermal Overload Relay
Definite Purpose Contactor
Relay
CDM6s Molded Case Circuit Breaker 063
CDM6L Earth-Leakage Circuit Breaker 086
CDM1 Molded Case Circuit Breaker 103
CDM1LE Earth-Leakage Circuit Breaker 112
CDC6 AC Contactor 194
CDR6 Thermal Overload Relay 210
CDC17-K Mini AC Contactor 220
CDR17-18 Thermal Overload Relay 223
CJX2 AC AC Contactor 227
JRS1D Thermal Overload Relay 233
JRS2 Thermal Overload Relay 238
CDZ6 Contactor Relay 248
CDZ8P Miniature Relay 251
JSZ3 Electronic Time Relay 253
XJ9 Phase Failure and Sequence Protection Relay 256
CDTL17 Impluse Relay 257
CDC9 Capacitor Switching Contactor 246
CDW9 Air Circuit Breaker 120
CDW6 Air Circuit Breaker 169
III
265-266
267-270
271-283
284-287
288-294
Power Energy Management
Motor Protector
Magnetic Starter
Current Transformer
Meter
Digital Time Switch
Voltage Stabilizer
258-264
CDP6 Motor Protector 258
CDS2 Magnetic Starter 265
LMK Series Current Transformer 267
DDS607 Single-phase Electronic Watt-hour Meter 271
DTS607 Three-phase Four-Wire Electronic Watt-hour Meter 273
DSS607 Three-phase Three-Wire Electronic Watt-hour Meter 276
72 Series Panel Meter 279
96 Series Panel Meter 281
KG316T Digital Time Switch 284
KG316TD Digital Time Switch 285
KG816 Digital Time Switch 286
TND Single-phase Full Automatic AC Voltage Stabilizer 288
SJW Three-phase Full Automatic AC Voltage Stabilizer 290
SBW Three-phase Compensation AC Voltage Stabilizer 292
IV
321-327
328-333
334-339
Industrial Control Components
Control Signal
Fuse
Industrial Plug&Socket
Accessories
295-320
LD11 Indicator Light 295
LAY5 Pushbutton Switches 299
LAY7 Pushbutton Switches 309
LAY8 Pushbutton Switches 315
CDPM Moving Industrial Plugs 328
CDP Fixed Industrial Plugs 329
CDSM Moving Industrial Sockets 330
CDSF Fixed Industrial Sockets 331
CDPS Multi-function Plugs and Sockets 332
CCF Cable Connector 334
TB Copper Terminal Blocks 335
DIN Din-rail 339
RT16 Fuse 321
RT18 Fuse 324
001
Final
Distribution
046
S
002 007 011 016
027
025
023
021
019
*
17
Miniature Circuit Breaker & Switch Disconnectors
Product Overview
18mm MCB
18mm 1P+N MCB
Accessories
Switch Disconnectors
27mm MCB
CDB6
CDB6p CDB6IS
CDB3 CDB5 CDG9
CDB6s
In: 1-63A
Breaking Capacity: 3/4.5/6kA
In: 6-32A
Breaking Capacity: 4.5kA
In: 20-125A
In: 6-32A
Breaking Capacity: 3kA
MX+OF SD OF
In: 20-100A In: 32-125A
In: 1-63A
Breaking Capacity: 4.5/6kA
CDB2
In: 63-125A
Breaking Capacity: 10kA
CDB9
In: 1-63A
Breaking Capacity: 6/10kA
002
Final
Distribution
Function
1
3
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
2
2
1
3
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
4
4
CDB6a1D1
CDB6a1D3
CDB6a1D6
CDB6a1D10
CDB6a1D16
CDB6a1D20
CDB6a1D25
CDB6a1D32
CDB6a1D40
CDB6a1D50
CDB6a1D63
CDB6a2D1
CDB6a2D3
CDB6a2D6
CDB6a2D10
CDB6a2D16
CDB6a2D20
CDB6a2D25
CDB6a2D32
CDB6a2D40
CDB6a2D50
CDB6a2D63
CDB6a1B1
CDB6a1B3
CDB6a1B6
CDB6a1B10
CDB6a1B16
CDB6a1B20
CDB6a1B25
CDB6a1B32
CDB6a1B40
CDB6a1B50
CDB6a1B63
CDB6a2B1
CDB6a2B3
CDB6a2B6
CDB6a2B10
CDB6a2B16
CDB6a2B20
CDB6a2B25
CDB6a2B32
CDB6a2B40
CDB6a2B50
CDB6a2B63
CDB6a1C1
CDB6a1C3
CDB6a1C6
CDB6a1C10
CDB6a1C16
CDB6a1C20
CDB6a1C25
CDB6a1C32
CDB6a1C40
CDB6a1C50
CDB6a1C63
CDB6a2C1
CDB6a2C3
CDB6a2C6
CDB6a2C10
CDB6a2C16
CDB6a2C20
CDB6a2C25
CDB6a2C32
CDB6a2C40
CDB6a2C50
CDB6a2C63
3
CDB6 a: 3kA
L: 4.5kA
N: 6kA
1: 1P
2: 2P
3: 3P
4: 4P
B: B Curve
C: C Curve
D: D Curve
1: 1A
3: 3A
…
63: 63A
1
3
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
2
2
CDB6N1B1
CDB6N1B3
CDB6N1B6
CDB6N1B10
CDB6N1B16
CDB6N1B20
CDB6N1B25
CDB6N1B32
CDB6N1B40
-
-
CDB6N1C1
CDB6N1C3
CDB6N1C6
CDB6N1C10
CDB6N1C16
CDB6N1C20
CDB6N1C25
CDB6N1C32
CDB6N1C40
-
-
-
-
-
-
-
-
-
-
-
-
-
CDB6L1D1
CDB6L1D3
CDB6L1D6
CDB6L1D10
CDB6L1D16
CDB6L1D20
CDB6L1D25
CDB6L1D32
CDB6L1D40
CDB6L1D50
CDB6L1D63
CDB6L1C1
CDB6L1C3
CDB6L1C6
CDB6L1C10
CDB6L1C16
CDB6L1C20
CDB6L1C25
CDB6L1C32
CDB6L1C40
CDB6L1C50
CDB6L1C63
CDB6L1B1
CDB6L1B3
CDB6L1B6
CDB6L1B10
CDB6L1B16
CDB6L1B20
CDB6L1B25
CDB6L1B32
CDB6L1B40
CDB6L1B50
CDB6L1B63
1
3
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
2
2
4.5
6
2P 3
Type
Name Breaking Capacity
Rating
(A)
Width
D curve
Reference
Pole Type Rated current
C curve
B curve
Breaking
Capacity
(kA)
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A
Order Information
Note: Width refers to multiple of 9 mm.
CDB6 miniature circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
1P
003
Final
Distribution
Order Information
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A
CDB6L2D1
CDB6L2D3
CDB6L2D6
CDB6L2D10
CDB6L2D16
CDB6L2D20
CDB6L2D25
CDB6L2D32
CDB6L2D40
CDB6L2D50
CDB6L2D63
CDB6L2C1
CDB6L2C3
CDB6L2C6
CDB6L2C10
CDB6L2C16
CDB6L2C20
CDB6L2C25
CDB6L2C32
CDB6L2C40
CDB6L2C50
CDB6L2C63
CDB6L2B1
CDB6L2B3
CDB6L2B6
CDB6L2B10
CDB6L2B16
CDB6L2B20
CDB6L2B25
CDB6L2B32
CDB6L2B40
CDB6L2B50
CDB6L2B63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
4
4
CDB6N2B1
CDB6N2B3
CDB6N2B6
CDB6N2B10
CDB6N2B16
CDB6N2B20
CDB6N2B25
CDB6N2B32
CDB6N2B40
-
-
CDB6N2C1
CDB6N2C3
CDB6N2C6
CDB6N2C10
CDB6N2C16
CDB6N2C20
CDB6N2C25
CDB6N2C32
CDB6N2C40
-
-
-
-
-
-
-
-
-
-
-
-
-
4
4
4
4
4
4
4
4
4
4
4
4.5
6
1
3
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
CDB6a3D1
CDB6a3D3
CDB6a3D6
CDB6a3D10
CDB6a3D16
CDB6a3D20
CDB6a3D25
CDB6a3D32
CDB6a3D40
CDB6a3D50
CDB6a3D63
CDB6a3B1
CDB6a3B3
CDB6a3B6
CDB6a3B10
CDB6a3B16
CDB6a3B20
CDB6a3B25
CDB6a3B32
CDB6a3B40
CDB6a3B50
CDB6a3B63
CDB6a3C1
CDB6a3C3
CDB6a3C6
CDB6a3C10
CDB6a3C16
CDB6a3C20
CDB6a3C25
CDB6a3C32
CDB6a3C40
CDB6a3C50
CDB6a3C63
3
CDB6L3D1
CDB6L3D3
CDB6L3D6
CDB6L3D10
CDB6L3D16
CDB6L3D20
CDB6L3D25
CDB6L3D32
CDB6L3D40
CDB6L3D50
CDB6L3D63
CDB6L3C1
CDB6L3C3
CDB6L3C6
CDB6L3C10
CDB6L3C16
CDB6L3C20
CDB6L3C25
CDB6L3C32
CDB6L3C40
CDB6L3C50
CDB6L3C63
CDB6L3B1
CDB6L3B3
CDB6L3B6
CDB6L3B10
CDB6L3B16
CDB6L3B20
CDB6L3B25
CDB6L3B32
CDB6L3B40
CDB6L3B50
CDB6L3B63
1
3
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
4.5
Type
Rating
(A)
Width
D curve
Reference
C curve
Breaking
Capacity
(kA) B curve
3P
Note: Width refers to multiple of 9 mm.
004
Final
Distribution
Order Information
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A
Note: Width refers to multiple of 9 mm.
CDB6a4D1
CDB6a4D3
CDB6a4D6
CDB6a4D10
CDB6a4D16
CDB6a4D20
CDB6a4D25
CDB6a4D32
CDB6a4D40
CDB6a4D50
CDB6a4D63
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CDB6a4B1
CDB6a4B3
CDB6a4B6
CDB6a4B10
CDB6a4B16
CDB6a4B20
CDB6a4B25
CDB6a4B32
CDB6a4B40
CDB6a4B50
CDB6a4B63
CDB6N3B1
CDB6N3B3
CDB6N3B6
CDB6N3B10
CDB6N3B16
CDB6N3B20
CDB6N3B25
CDB6N3B32
CDB6N3B40
-
-
CDB6a4C1
CDB6a4C3
CDB6a4C6
CDB6a4C10
CDB6a4C16
CDB6a4C20
CDB6a4C25
CDB6a4C32
CDB6a4C40
CDB6a4C50
CDB6a4C63
CDB6N3C1
CDB6N3C3
CDB6N3C6
CDB6N3C10
CDB6N3C16
CDB6N3C20
CDB6N3C25
CDB6N3C32
CDB6N3C40
-
-
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
8
8
8
8
8
8
8
8
8
8
8
6
6
6
6
6
6
6
6
6
6
6
3
6
Type
Rating
(A)
Width
D curve
Reference
C curve
Breaking
Capacity
(kA) B curve
4P
CDB6L4D1
CDB6L4D3
CDB6L4D6
CDB6L4D10
CDB6L4D16
CDB6L4D20
CDB6L4D25
CDB6L4D32
CDB6L4D40
CDB6L4D50
CDB6L4D63
CDB6L4C1
CDB6L4C3
CDB6L4C6
CDB6L4C10
CDB6L4C16
CDB6L4C20
CDB6L4C25
CDB6L4C32
CDB6L4C40
CDB6L4C50
CDB6L4C63
CDB6N4C1
CDB6N4C3
CDB6N4C6
CDB6N4C10
CDB6N4C16
CDB6N4C20
CDB6N4C25
CDB6N4C32
CDB6N4C40
-
-
CDB6L4B1
CDB6L4B3
CDB6L4B6
CDB6L4B10
CDB6L4B16
CDB6L4B20
CDB6L4B25
CDB6L4B32
CDB6L4B40
CDB6L4B50
CDB6L4B63
CDB6N4B1
CDB6N4B3
CDB6N4B6
CDB6N4B10
CDB6N4B16
CDB6N4B20
CDB6N4B25
CDB6N4B32
CDB6N4B40
-
-
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
4.5
6
005
Final
Distribution
Technical Data
IEC60898-1
CB, CE, RoHS
1-4P
1,3,6,10,16,20,25,32,40,50,63 A
230/400V AC
500V
3
4.5
6
4.5
B,C,D
B,C,D
B,C
B,C
230/400
400
230/400
400
230/400
400
230/400
400
1-63
1-63
1-40
50,63
Accessories
Contact Accessory
Fault-indicating Accessories
Shunt -trip release
OF
SD
MX+OF
35mm Din-rail
Rate
Current(A)
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
B Curve:the magnetic release operates between 3 and 5 In
C Curve:the magnetic release operates between 5 and 10 In
D Curve:the magnetic release operates between 10 and 14 In
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
4000 times
10000 times
2
treatment 2
-5°C ~ +40°C
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
1-63 M5
Up to 25mm2
cables
2.5 4.5
Mounting
Installation
Connection
Mechanical
Features
Electrical
Features
MCB CDB6 18mm Circuit Breaker
Breaking Capacity Icn
Tripping Curve(see following tripping curve pictures)
Rate
current(A)
Breaking
capacity lcn(kA)
Type
1P
2P, 3P, 4P
1P
2P, 3P, 4P
1P
2P, 3P, 4P
1P
2P, 3P, 4P
Poles Voltage
(V)
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A
006
Final
Distribution
SD OF CDB6 MX+OF
Tripping Curve
Overall Dimensions
Accessories
CDB6 Miniature Circuit Breaker
The Sketch Map of Installation with Breakers
CDB6 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A
007
Final
Distribution
Function
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A
CDB6s miniature circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
2P 4.5/6 CDB6sN2B1
CDB6sN2B2
CDB6sN2B3
CDB6sN2B4
CDB6sN2B5
CDB6sN2B6
CDB6sN2B8
CDB6sN2B10
CDB6sN2B13
CDB6sN2B16
CDB6sN2B20
CDB6sN2B25
CDB6sN2B32
CDB6sN2B40
CDB6sL2B50
CDB6sL2B63
CDB6sN2C1
CDB6sN2C2
CDB6sN2C3
CDB6sN2C4
CDB6sN2C5
CDB6sN2C6
CDB6sN2C8
CDB6sN2C10
CDB6sN2C13
CDB6sN2C16
CDB6sN2C20
CDB6sN2C25
CDB6sN2C32
CDB6sN2C40
CDB6sL2C50
CDB6sL2C63
CDB6sL2D1
CDB6sL2D2
CDB6sL2D3
CDB6sL2D4
CDB6sL2D5
CDB6sL2D6
CDB6sL2D8
CDB6sL2D10
CDB6sL2D13
CDB6sL2D16
CDB6sL2D20
CDB6sL2D25
CDB6sL2D32
CDB6sL2D40
CDB6sL2D50
CDB6sL2D63
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1P
Note: Width refers to multiple of 9 mm.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4.5/6 CDB6sN1B1
CDB6sN1B2
CDB6sN1B3
CDB6sN1B4
CDB6sN1B5
CDB6sN1B6
CDB6sN1B8
CDB6sN1B10
CDB6sN1B13
CDB6sN1B16
CDB6sN1B20
CDB6sN1B25
CDB6sN1B32
CDB6sN1B40
CDB6sL1B50
CDB6sL1B63
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
CDB6sN1C1
CDB6sN1C2
CDB6sN1C3
CDB6sN1C4
CDB6sN1C5
CDB6sN1C6
CDB6sN1C8
CDB6sN1C10
CDB6sN1C13
CDB6sN1C16
CDB6sN1C20
CDB6sN1C25
CDB6sN1C32
CDB6sN1C40
CDB6sL1C50
CDB6sL1C63
CDB6sL1D1
CDB6sL1D2
CDB6sL1D3
CDB6sL1D4
CDB6sL1D5
CDB6sL1D6
CDB6sL1D8
CDB6sL1D10
CDB6sL1D13
CDB6sL1D16
CDB6sL1D20
CDB6sL1D25
CDB6sL1D32
CDB6sL1D40
CDB6sL1D50
CDB6sL1D63
Type
Breaking
Capacity (kA)
Rating
(A)
Width
D curve
C curve
Reference
B curve
Order Information
CDB6s L: 4.5kA
N: 6kA
1: 1P
2: 2P
3: 3P
4: 4P
B: B Curve
C: C Curve
D: D Curve
1: 1A
2: 2A
…
63: 63A
Name Breaking Capacity Pole Type Rated current
008
Final
Distribution
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A
Order Information
4.5/6
Type
Breaking
Capacity (kA)
Rating
(A)
Width
D curve
C curve
Reference
B curve
CDB6sN3B1
CDB6sN3B2
CDB6sN3B3
CDB6sN3B4
CDB6sN3B5
CDB6sN3B6
CDB6sN3B8
CDB6sN3B10
CDB6sN3B13
CDB6sN3B16
CDB6sN3B20
CDB6sN3B25
CDB6sN3B32
CDB6sN3B40
CDB6sL3B50
CDB6sL3B63
CDB6sN3C1
CDB6sN3C2
CDB6sN3C3
CDB6sN3C4
CDB6sN3C5
CDB6sN3C6
CDB6sN3C8
CDB6sN3C10
CDB6sN3C13
CDB6sN3C16
CDB6sN3C20
CDB6sN3C25
CDB6sN3C32
CDB6sN3C40
CDB6sL3C50
CDB6sL3C63
CDB6sL3D1
CDB6sL3D2
CDB6sL3D3
CDB6sL3D4
CDB6sL3D5
CDB6sL3D6
CDB6sL3D8
CDB6sL3D10
CDB6sL3D13
CDB6sL3D16
CDB6sL3D20
CDB6sL3D25
CDB6sL3D32
CDB6sL3D40
CDB6sL3D50
CDB6sL3D63
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
3P
4P 4.5/6
CDB6sN4B1
CDB6sN4B2
CDB6sN4B3
CDB6sN4B4
CDB6sN4B5
CDB6sN4B6
CDB6sN4B8
CDB6sN4B10
CDB6sN4B13
CDB6sN4B16
CDB6sN4B20
CDB6sN4B25
CDB6sN4B32
CDB6sN4B40
CDB6sL4B50
CDB6sL4B63
CDB6sN4C1
CDB6sN4C2
CDB6sN4C3
CDB6sN4C4
CDB6sN4C5
CDB6sN4C6
CDB6sN4C8
CDB6sN4C10
CDB6sN4C13
CDB6sN4C16
CDB6sN4C20
CDB6sN4C25
CDB6sN4C32
CDB6sN4C40
CDB6sL4C50
CDB6sL4C63
CDB6sL4D1
CDB6sL4D2
CDB6sL4D3
CDB6sL4D4
CDB6sL4D5
CDB6sL4D6
CDB6sL4D8
CDB6sL4D10
CDB6sL4D13
CDB6sL4D16
CDB6sL4D20
CDB6sL4D25
CDB6sL4D32
CDB6sL4D40
CDB6sL4D50
CDB6sL4D63
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Note: Width refers to multiple of 9 mm.
009
Final
Distribution
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A
Technical Data
1P 230/400
2P, 3P, 4P 400
6 B,C
1-40
4.5 B,C
50,63 1P 230/400
2P, 3P, 4P 400
4.5 D
1-63 1P 230/400
2P, 3P, 4P 400
Breaking
capacity lcn(kA)
Accessories
Contact Accessory
Fault-indicating Accessory
Shunt-trip Release
OF
SD
MX+OF
35mm Din-rail
Rate
Current(A)
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperture
B curve;the magnetic release operates between 3 and 5 In
C curve;the magnetic release operates between 5 and 10 In
D curve;the magnetic release operates between 10 and 14 In
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
IEC 60898-1
KEMA CB CE
1-4P
1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A
230/400V AC
500V
4000 times
10000 times
2
treatment 2
-5°C ~ +40°C
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
1-63 M5
Up to 25mm2
cables
2.5 4.5
Mounting
Installation
Connection
Mechanical
Features
Electrical
Features
MCB CDB6s 18mm Circuit Breaker
Breaking Capacity Icn
Tripping Curve ( see following tripping curve pictures)
Rate
current(A)
Type Poles Voltage
(V)
010
Final
Distribution
CDB6s 18mm Miniature Circuit Breaker
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A
Tripping Curves
Overall Dimensions
Accessories
SD OF MX+OF
CDB6s
:67.21–0.43
88
max
4P
3P
2P
1P
Unit: mm
011
Final
Distribution
Function CDB9 miniature circuit breakers combine the following functions:
● Protection of circuits against overload currents
● Protection of circuits against short-circuit currents
● Control
● Isolation
Type
Breaking
Capacity(kA)
Rating(A) Width
Reference
B Curve C Curve D Curve
1P 6 1 2 CDB9N631B1 CDB9N631C1 CDB9N631D1
2 2 CDB9N631B2 CDB9N631C2 CDB9N631D2
4 2 CDB9N631B4 CDB9N631C4 CDB9N631D4
6 2 CDB9N631B6 CDB9N631C6 CDB9N631D6
10 2 CDB9N631B10 CDB9N631C10 CDB9N631D10
16 2 CDB9N631B16 CDB9N631C16 CDB9N631D16
20 2 CDB9N631B20 CDB9N631C20 CDB9N631D20
25 2 CDB9N631B25 CDB9N631C25 CDB9N631D25
32 2 CDB9N631B32 CDB9N631C32 CDB9N631D32
40 2 CDB9N631B40 CDB9N631C40 CDB9N631D40
50 2 CDB9N631B50 CDB9N631C50 CDB9N631D50
63 2 CDB9N631B63 CDB9N631C63 CDB9N631D63
10 1 2 CDB9H631B1 CDB9H631C1 CDB9H631D1
2 2 CDB9H631B2 CDB9H631C2 CDB9H631D2
4 2 CDB9H631B4 CDB9H631C4 CDB9H631D4
6 2 CDB9H631B6 CDB9H631C6 CDB9H631D6
10 2 CDB9H631B10 CDB9H631C10 CDB9H631D10
16 2 CDB9H631B16 CDB9H631C16 CDB9H631D16
20 2 CDB9H631B20 CDB9H631C20 CDB9H631D20
25 2 CDB9H631B25 CDB9H631C25 CDB9H631D25
32 2 CDB9H631B32 CDB9H631C32 CDB9H631D32
40 2 CDB9H631B40 CDB9H631C40 CDB9H631D40
50 2 CDB9H631B50 CDB9H631C50 CDB9H631D50
63 2 CDB9H631B63 CDB9H631C63 CDB9H631D63
Note:Width refers to multiple of 9 mm.
B curve products need to customize
Name
Breaking
Capacity(kA)
Frame Size Pole Type Rated current
CDB9 N: 6kA 63:63AF 1:1P B:B Curve 1:1A
H: 10kA 2:2P C:C Curve 2:2A
3:3P D:D Curve ···
4:4P 63:63A
Order Information
CDB9 18mm Miniature Circuit Breaker
Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A
012
Final
Distribution
Note:Width refers to multiple of 9 mm.
B curve products need to customize
Type
Breaking
Capacity(kA)
Rating(A) Width
Reference
B Curve C Curve D Curve
2P 6 1 4 CDB9N632B1 CDB9N632C1 CDB9N632D1
2 4 CDB9N632B2 CDB9N632C2 CDB9N632D2
4 4 CDB9N632B4 CDB9N632C4 CDB9N632D4
6 4 CDB9N632B6 CDB9N632C6 CDB9N632D6
10 4 CDB9N632B10 CDB9N632C10 CDB9N632D10
16 4 CDB9N632B16 CDB9N632C16 CDB9N632D16
20 4 CDB9N632B20 CDB9N632C20 CDB9N632D20
25 4 CDB9N632B25 CDB9N632C25 CDB9N632D25
32 4 CDB9N632B32 CDB9N632C32 CDB9N632D32
40 4 CDB9N632B40 CDB9N632C40 CDB9N632D40
50 4 CDB9N632B50 CDB9N632C50 CDB9N632D50
63 4 CDB9N632B63 CDB9N632C63 CDB9N632D63
10 1 4 CDB9H632B1 CDB9H632C1 CDB9H632D1
2 4 CDB9H632B2 CDB9H632C2 CDB9H632D2
4 4 CDB9H632B4 CDB9H632C4 CDB9H632D4
6 4 CDB9H632B6 CDB9H632C6 CDB9H632D6
10 4 CDB9H632B10 CDB9H632C10 CDB9H632D10
16 4 CDB9H632B16 CDB9H632C16 CDB9H632D16
20 4 CDB9H632B20 CDB9H632C20 CDB9H632D20
25 4 CDB9H632B25 CDB9H632C25 CDB9H632D25
32 4 CDB9H632B32 CDB9H632C32 CDB9H632D32
40 4 CDB9H632B40 CDB9H632C40 CDB9H632D40
50 4 CDB9H632B50 CDB9H632C50 CDB9H632D50
63 4 CDB9H632B63 CDB9H632C63 CDB9H632D63
6 1 6 CDB9N633B1 CDB9N633C1 CDB9N633D1
2 6 CDB9N633B2 CDB9N633C2 CDB9N633D2
4 6 CDB9N633B4 CDB9N633C4 CDB9N633D4
6 6 CDB9N633B6 CDB9N633C6 CDB9N633D6
10 6 CDB9N633B10 CDB9N633C10 CDB9N633D10
16 6 CDB9N633B16 CDB9N633C16 CDB9N633D16
20 6 CDB9N633B20 CDB9N633C20 CDB9N633D20
25 6 CDB9N633B25 CDB9N633C25 CDB9N633D25
32 6 CDB9N633B32 CDB9N633C32 CDB9N633D32
40 6 CDB9N633B40 CDB9N633C40 CDB9N633D40
50 6 CDB9N633B50 CDB9N633C50 CDB9N633D50
63 6 CDB9N633B63 CDB9N633C63 CDB9N633D63
3P
Order Information
CDB9 18mm Miniature Circuit Breaker
Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A
013
Final
Distribution
Note:Width refers to multiple of 9 mm.
B curve products need to customize
Type
Breaking
Capacity(kA)
Rating(A) Width
Reference
B Curve C Curve D Curve
10 1 6 CDB9H633B1 CDB9H633C1 CDB9H633D1
2 6 CDB9H633B2 CDB9H633C2 CDB9H633D2
4 6 CDB9H633B4 CDB9H633C4 CDB9H633D4
6 6 CDB9H633B6 CDB9H633C6 CDB9H633D6
10 6 CDB9H633B10 CDB9H633C10 CDB9H633D10
16 6 CDB9H633B16 CDB9H633C16 CDB9H633D16
20 6 CDB9H633B20 CDB9H633C20 CDB9H633D20
25 6 CDB9H633B25 CDB9H633C25 CDB9H633D25
32 6 CDB9H633B32 CDB9H633C32 CDB9H633D32
40 6 CDB9H633B40 CDB9H633C40 CDB9H633D40
50 6 CDB9H633B50 CDB9H633C50 CDB9H633D50
63 6 CDB9H633B63 CDB9H633C63 CDB9H633D63
6 1 8 CDB9N634B1 CDB9N634C1 CDB9N634D1
2 8 CDB9N634B2 CDB9N634C2 CDB9N634D2
4 8 CDB9N634B4 CDB9N634C4 CDB9N634D4
6 8 CDB9N634B6 CDB9N634C6 CDB9N634D6
10 8 CDB9N634B10 CDB9N634C10 CDB9N634D10
16 8 CDB9N634B16 CDB9N634C16 CDB9N634D16
20 8 CDB9N634B20 CDB9N634C20 CDB9N634D20
25 8 CDB9N634B25 CDB9N634C25 CDB9N634D25
32 8 CDB9N634B32 CDB9N634C32 CDB9N634D32
40 8 CDB9N634B40 CDB9N634C40 CDB9N634D40
50 8 CDB9N634B50 CDB9N634C50 CDB9N634D50
63 8 CDB9N634B63 CDB9N634C63 CDB9N634D63
10 1 8 CDB9H634B1 CDB9H634C1 CDB9H634D1
2 8 CDB9H634B2 CDB9H634C2 CDB9H634D2
4 8 CDB9H634B4 CDB9H634C4 CDB9H634D4
6 8 CDB9H634B6 CDB9H634C6 CDB9H634D6
10 8 CDB9H634B10 CDB9H634C10 CDB9H634D10
16 8 CDB9H634B16 CDB9H634C16 CDB9H634D16
20 8 CDB9H634B20 CDB9H634C20 CDB9H634D20
25 8 CDB9H634B25 CDB9H634C25 CDB9H634D25
32 8 CDB9H634B32 CDB9H634C32 CDB9H634D32
40 8 CDB9H634B40 CDB9H634C40 CDB9H634D40
50 8 CDB9H634B50 CDB9H634C50 CDB9H634D50
63 8 CDB9H634B63 CDB9H634C63 CDB9H634D63
4P
Order Information
CDB9 18mm Miniature Circuit Breaker
Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A
014
Final
Distribution
Technical Date
MCB CDB9 18mm Circuit Breaker
Electrical
Features
Standard IEC 60898-1
Certification KEMA CB CE
Poles l-4P
Rated Current In
l,2,4,6,10,16,20,25,32,40,50,63A
Rated Voltage Ue 230/400V AC
Insulation Voltage Ui 500V
Breaking Capacity Icn
Rate
Current(A)
Breaking
Capacity Icn(kA)
Type Poles
Voltage
(V)
1-63 6 B,C,D 1P 230/400
2P,3P,4P 400
1-63 10 B,C,D 1P 230/400
2P,3P,4P 400
Tripping Curve(see following tripping curve pictures)
B curve; the magnetic release operates between 3 and 5 In
C curve; the magnetic release operates between 5 and 10 In
D curve; the magnetic release operates between 10 and 14 In
Mechanical
Features
Electrical Durability 10000 times
Mechanical Durability 20000 times
Protection Degree 2
Ambient Temperture -30 °C~+70°C
Connection 1-32A Up to 25mm² cables 40-63 Up to 35mm² cables
lnstallation
Rate
Current(A)
Screw Rated Torque(Nm) Limiting Torque(Nm)
1-32 M5 2.0 2.5
40-63 M6.5 3.5 2.5
Mounting 35mm Din-rail
Accessories
Contact Accessory OF
Fault-Indicating Accessory SD
Shunt-Trip Release MX+OF
CDB9 18mm Miniature Circuit Breaker
Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A
015
Final
Distribution
Tripping Curve
Overall Dimensions
Accessories
CDB9 18mm Miniature Circuit Breaker
Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A
016
Final
Distribution
Function
63
80
100
125
6
6
6
6
2P CDB2H2D63
CDB2H2D80
CDB2H2D100
CDB2H2D125
CDB2H2C63
CDB2H2C80
CDB2H2C100
CDB2H2C125
63
80
100
125
9
9
9
9
3P CDB2H3D63
CDB2H3D80
CDB2H3D100
CDB2H3D125
CDB2H3C63
CDB2H3C80
CDB2H3C100
CDB2H3C125
63
80
100
125
12
12
12
12
4P CDB2H4C63
CDB2H4C80
CDB2H4C100
CDB2H4C125
CDB2H4D63
CDB2H4D80
CDB2H4D100
CDB2H4D125
Type Rating
(A)
Width
(in mod.of 9mm)
Reference
C curve D curve
63
80
100
125
3
3
3
3
CDB2H1D63
CDB2H1D80
CDB2H1D100
CDB2H1D125
1P CDB2H1C63
CDB2H1C80
CDB2H1C100
CDB2H1C125
Order Information
CDB2 miniature circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
CDB2 27mm Miniature Circuit Breaker
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
017
Final
Distribution
Technical Data
CDB2 27mm Miniature Circuit Breaker
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
1-4P
63,80,100,125A
230/400V AC
500V
IEC60947-2
CB, SEMKO, CE, RoHS
Accessories
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Mounting
Installation
Connection
Mechanical
Features
Electrical
Features
Rating
(A)
Rate
current(A)
Contact Accessory:
Shunt-trip Release:
OF
MX+OF
63-125 M7 4 5.5
63~125 1P
2P,3P,4P
230
400
10
10
Poles
Screw
Voltage
(V)
Rated Torque
(Nm)
Breaking capacity
(kA)
Limiting Torque
(Nm)
MCB CDB2 27mm Circuit Breaker
Breaking Capacity Icn
Up to 50mm2
cables
35mm Din-rail
Tripping Curve (see following tripping curve pictures)
(C curve the magnetic release operates between 5 and 10 In)
(D curve the magnetic release operates between 10 and 14 In)
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
2
treatment 2
-5°C ~ +40°C
018
Final
Distribution
CDB2 27mm Miniature Circuit Breaker
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
MX+OF OF CDB2
Tripping Curves
Overall Dimensions
Accessories
019
Final
Distribution
Function
CDB6p Phase-neutral Circuit Breaker
Standard: IEC 60898-1
Trip Curve: C curve
Breaking Capacity: 4500A
Order Information
CDB6p phase-neutral circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
6
10
16
20
25
32
2
2
2
2
2
2
CDB6pC6
CDB6pC10
CDB6pC16
CDB6pC20
CDB6pC25
CDB6pC32
1P+N
Technical Data
IEC60898-1
CB
1P+N
6,10,16,20,25,32A
230V AC
500V
4.5KA
Breaking Capacity Icn
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10In
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Rate
current(A)
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
6-32 M4 2 3
Electrical
Features
2
treatment 2
-5℃~+40℃
Protection Degree
Ambient Temperature
Tropicalization
4000 times
16000 times
Electrical Durability
Mechanical Durability
Up to 10mm cables
2
35mm Din-rail
Mechanical
Features
MCB
Connection
Installation
Mounting
CDB6p Phase-neutral Circuit Breaker
Function
020
Final
Distribution
45
18
78
88max
35
5.5
70max
CDB6p Phase-neutral Circuit Breaker
Tripping Curve
CDB6p Phase-neutral Circuit Breaker
Standard: IEC 60898-1
Trip Curve: C curve
Breaking Capacity: 4500A
Overall Dimensions
021
Final
Distribution
Function
Electrical
Features
Order Information
Technical Data
Mechanical
Features
MCB
Connection
Installation
Mounting
CDB3 Phase-neutral Circuit Breaker
Tripping Curve (see following tripping curve pictures)
Up to 10mm2 cables
35mm Din-rail
C curve:the magnetic release operates between 5 and 10In
CDB3 Phase-neutral Circuit Breaker
Standard: IEC 60898-1
Trip Curve: C curves
Breaking Capacity: 3000A
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity Icn
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
4000 times
16000 times
2
treatment 2
-5°C ~ +40°C
Rate
current(A)
6-32 M4 2 3
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
IEC60898-1
CE
1P+N
6,10,16,20,25,32A
230V AC
500V
3kA
CDB3 phase-neutral circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
6
10
16
20
25
32
2
2
2
2
2
2
CDB3a5C6
CDB3a5C10
CDB3a5C16
CDB3a5C20
CDB3a5C25
CDB3a5C32
1P+N
022
Final
Distribution
CDB3 Phase-neutral Circuit Breaker
Standard: IEC 60898-1
Trip Curve: C curves
Breaking Capacity: 3000A
Overall Dimensions
Tripping Curves
10000
5000
2000
1h
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.005
0.02
0.002
0.01
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200
023
Final
Distribution
Type
1P
3P
4P
2P
Width
(in mod.of 9mm)
2
2
2
2
6
6
6
6
8
8
8
8
4
4
4
4
Reference
CDB6IS120
CDB6IS132
CDB6IS163
CDB6IS1100
CDB6IS320
CDB6IS332
CDB6IS363
CDB6IS3100
CDB6IS420
CDB6IS432
CDB6IS463
CDB6IS4100
CDB6IS220
CDB6IS232
CDB6IS263
CDB6IS2100
Rating
(A)
20
32
63
100
20
32
63
100
20
32
63
100
20
32
63
100
Order Information
Standard: IEC 60947-3
CDB6IS Switch Disconnector
Making and breaking normal load circuits
Isolation
CDB6IS switch disconnectors combine the following functions:
Function
2 CDB6IS1125
125
4 CDB6IS2125
125
6 CDB6IS3125
125
8 CDB6IS4125
125
024
Final
Distribution
Standard: IEC 60947-3
CDB6IS Switch Disconnector
Technical Data
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Rate
current(A)
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
20-125 M7 4 5.5
l
CDB6IS Switch Disconnector
r
Standard
Capacity for 1s
Protection Degree
Ambient Temperature
Tropicalization
Up to 50mm cables
2
35mm Din-rai
Overall Dimensions
Electrical Durability
Mechanical Durability
2
- 5
。
C ~ +40
。
C
treatment 2
1500 times
8500 times
Switch Disconnector
Electrical
Features
20,
32,
63,
100,125A
500V
IEC60947-3
12le
1-4P
230/400V AC
Short-time Withstand
Connection
Installation
Mounting
Mechanical
Features
Certification CB,CE,SEMKO
025
Final
Distribution
Type Voltage
(V)
1P 230/400
3P 400
4P 400
2P
Width
(in mod.of 9mm)
2
2
2
2
6
6
6
6
8
8
8
8
4
4
4
4
400
Reference
CDB5120
CDB5132
CDB5163
CDB51100
CDB5320
CDB5332
CDB5363
CDB53100
CDB5420
CDB5432
CDB5463
CDB54100
CDB5220
CDB5232
CDB5263
CDB52100
Rating
(A)
20
32
63
100
20
32
63
100
20
32
63
100
20
32
63
100
Order Information
Standard: IEC 60947-3
CDB5 Switch Disconnector
CDB5 switch disconnectors combine the following functions:
Making and breaking normal load circuits
Isolation
Function
026
Final
Distribution
Standard: IEC 60947-3
CDB5 Switch Disconnector
Overall Dimensions
Technical Data
1500 times
8500 times
2
-5°C ~ +40°C
treatment 2
-25°C ~+55°C
Standard
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Rated Short-circuit
Making Capacity
Short-time Withstand
Capacity for 1s
Electrical Durability
Mechanical Durability
Protection Degree
Ambient Temperature
Tropicalization
Storage Temperature
IEC60947-3
1-4P
20, 32, 63, 100A
230/400V AC
500V
1066A(Ie:20~63A)
1692A(Ie:100A), Peak current
756A(Ie:20~63A)
1200A(Ie:100A)
Connection
Installation
Mounting
Mechanical
Features
Electrical
Features
Switch Disconnector CDB5 Switch Disconnector
Up to 50mm2 cables
Rate
current(A)
20-100 M7 4
35mm Din-rail
5.5
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
027
Final
Distribution
CDG9 Switch Disconnector
Standard:IEC 60947-3
Function CDG9 switch disconnectors combine the folIowing functions:
● Making and breaking normal load circuits
● Isolation
Type Rating(A)
Width
(in mod.of 9mm)
Reference
1P
32 2 CDG9125132
63 2 CDG9125163
100 2 CDG91251100
125 2 CDG91251125
2P
32 4 CDG9125232
63 4 CDG9125263
100 4 CDG91252100
125 4 CDG91252125
3P
32 6 CDG9125332
63 6 CDG9125363
100 6 CDG91253100
125 6 CDG91253125
4P
32 8 CDG9125432
63 8 CDG9125463
100 8 CDG91254100
125 8 CDG91254125
Order Information
028
Final
Distribution
CDG9 Switch Disconnector
Standard:IEC 60947-3
Overall Dimensions
Switch
Disconnector
CDG9 Switch Disconnector
Electrical
Features
Standard IEC 60947-3
Certification CB,CE,TUV
Poles 1-4P
Rated Current In 32,63,100,125A
Rated Voltage Ue 230/400VAC
Insulation Voltage Ui 500V
Short-time Withstand
Current for 1s 12le
Mechanical
Features
Electrical Durability 10000 times
Mechanical Durability 20000 times
Protection Degree 2
Ambient Temperture -30 °C~+70°C
Tropicalization treatment 2
Connection Up to 50mm² cables
lnstallation
Rate
current(A)
Screw Rated Torque(Nm) Limiting Torque(Nm)
32-125 M6.5 3.5 3.5
Mounting 35mm Din-rail
Technical Date
029
Final
Distribution
030
036
043 044
039 041
033
Residual Current Devices Overview
Sensitivity: 30,50,100,200,300mA
In: 6-60A
Breaking Capacity: 3kA
Poles: 1P+N, 2P, 3P, 3P+N, 4P
Sensitivity: 30,100,300mA
In: V32A, V63A
Poles: 1P+N, 2P, 3P, 3P+N, 4P
Sensitivity: 30,100,300mA
In: 63-100A
Breaking Capacity: 10kA
Poles: 1P+N, 2P, 3P, 3P+N, 4P
Sensitivity:30mA
Breaking Capacity:6000A
Poles: 1P+N
Sensitivity:30,100,300mA
In: 10-100A
Poles: 2P,4P
Sensitivity: 30mA
In: 6-40A
Breaking Capacity: 4.5kA
Poles: 1P+N
Sensitivity: 30mA
In: 6-40A
Breaking Capacity: 4.5kA
Poles: 1P+N
18mm RCBO
27mm RCBO
Add-on RCD
Phase-neutral RCBO
CDB6LE
CDB2LE
CDL6SP CDB6VR
CDB6pLE CDB3LE
CDB6v
RCCB
030
Final
Distribution
Function
CDB6LE Residual Current Operated Circuit Breaker
CDB6LE electronic type residual current operated circuit breakers combine the following functions:
Overload protection
Protection against short-circuit currents
Protection for users against indirect currents
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation
400
400
230
230
3P+N
3P
2P
1P+N
30
30
30
30
11
11
11
11
11
11
14
14
14
10
10
10
10
10
10
12
12
12
7
7
7
7
7
7
8
8
8
5
5
5
5
5
5
6
6
6
6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60
6
10
16
20
25
32
40
50
60
CDB6LEa3C6S
CDB6LEa3C10S
CDB6LEa3C16S
CDB6LEa3C20S
CDB6LEa3C25S
CDB6LEa3C32S
CDB6LEa3C40S
CDB6LEa3C50S
CDB6LEa3C60S
CDB6LEa2C6S
CDB6LEa2C10S
CDB6LEa2C16S
CDB6LEa2C20S
CDB6LEa2C25S
CDB6LEa2C32S
CDB6LEa2C40S
CDB6LEa2C50S
CDB6LEa2C60S
CDB6LEa1C6S
CDB6LEa1C10S
CDB6LEa1C16S
CDB6LEa1C20S
CDB6LEa1C25S
CDB6LEa1C32S
CDB6LEa1C40S
CDB6LEa1C50S
CDB6LEa1C60S
CDB6LEa6C6S
CDB6LEa6C10S
CDB6LEa6C16S
CDB6LEa6C20S
CDB6LEa6C25S
CDB6LEa6C32S
CDB6LEa6C40S
CDB6LEa6C50S
CDB6LEa6C60S
CDB6LEa3D6S
CDB6LEa3D10S
CDB6LEa3D16S
CDB6LEa3D20S
CDB6LEa3D25S
CDB6LEa3D32S
CDB6LEa3D40S
CDB6LEa3D50S
CDB6LEa3D60S
CDB6LEa1D6S
CDB6LEa1D10S
CDB6LEa1D16S
CDB6LEa1D20S
CDB6LEa1D25S
CDB6LEa1D32S
CDB6LEa1D40S
CDB6LEa1D50S
CDB6LEa1D60S
CDB6LEa6D6S
CDB6LEa6D10S
CDB6LEa6D16S
CDB6LEa6D20S
CDB6LEa6D25S
CDB6LEa6D32S
CDB6LEa6D40S
CDB6LEa6D50S
CDB6LEa6D60S
CDB6LEa2D6S
CDB6LEa2D10S
CDB6LEa2D16S
CDB6LEa2D20S
CDB6LEa2D25S
CDB6LEa2D32S
CDB6LEa2D40S
CDB6LEa2D50S
CDB6LEa2D60S
Type Width
Reference
C curve D curve
Voltage
(V)
Sensitivity
(mA)
Rating
(A)
Order Information
Note: 1. Width refers to multiple of 9 mm.
2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with
"W";100mA is marked with "Y";200mA is marked with "R";300mA is marked with "T".
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA
031
Final
Distribution
Type Width Reference
C curve D curve
Voltage
(V)
Sensitivity
(mA)
Rating
(A)
Order Information
400
4P 30 CDB6LEa4C6S
CDB6LEa4C10S
CDB6LEa4C16S
CDB6LEa4C20S
CDB6LEa4C25S
CDB6LEa4C32S
CDB6LEa4C40S
CDB6LEa4C50S
CDB6LEa4C60S
CDB6LEa4D6S
CDB6LEa4D10S
CDB6LEa4D16S
CDB6LEa4D20S
CDB6LEa4D25S
CDB6LEa4D32S
CDB6LEa4D40S
CDB6LEa4D50S
CDB6LEa4D60S
6
10
16
20
25
32
40
50
60
13
13
13
13
13
13
16
16
16
CDB6LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA
Note: 1. Width sensitivity refers to multiple of 9 mm.
2. If the sensitivity is 30mA,it's marked with "S" in the reference number.Also, 50mA is marked with
"W";100mA is marked with "Y";200mA is marked with "R";300mA is marked with "T".
Technical Data
Installation
Mounting
Accessories
Connection
Mechanical
Features
Electrical
Features
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
RCBO CDB6LE Residual Current Operated Circuit Breaker
Tripping Curve(see following tripping curve pictures)
6-32A,Up to 16mm2
cables, 40-60A,Up to 25mm2
cables
35mm Din-rail
Contact Accessory:
Fault-indicating Accessory:
OF
SD
C curve:the magnetic release operates between 5 and 10
D curve:the magnetic release operates between 10 and 14
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
2000 times
2000 times
2
treatment 2
-5°C ~ +40°C
IEC 61009-1
AC
1P+N,2P,3P,3P+N,4P
6,10,16,20,25,32,40,50,60A
230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P
500V
3KA
30,50,100,200,300mA
Rate
current(A)
6-32
40-60
M4
M5
2.0
2.5
3.0
4.5
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
032
Final
Distribution
CDB6LE-60
CDB6LE-32
CDB6LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA
Tripping Curves
Accessories
CDB6LE
OF
SD
Overall Dimensions
033
Final
Distribution
Order Information
Function CDB6v can be assembled with CDB6s to be residual current breaker overcurrent
Protection of persons against indirect contacting
Supplementary protection of persons against direct contacting
Prevention of electric-caused fire
Overvoltage protection by products marked "G"
Note: Width refers to mutultiple of 9mm.
CDB6v Residual Current Protection Module
Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA
Frame Type
Voltage
(V)
Sensitivity
(mA)
Width Reference
V32 1P+N 230 30 5 CDB6v321N
100 5 CDB6v321NR100
300 5 CDB6v321NR300
2P 230 30 7 CDB6v322P
100 7 CDB6v322PR100
300 7 CDB6v322PR300
3P 400 30 10 CDB6v323P
100 10 CDB6v323PR100
300 10 CDB6v323PR300
3P+N 30 11 CDB6v323N
100 11 CDB6v323NR100
300 11 CDB6v323NR300
4P 30 13 CDB6v324P
100 13 CDB6v324PR100
300 13 CDB6v324PR300
V63 1P+N 230 30 6 CDB6v631N
100 6 CDB6v631NR100
300 6 CDB6v631NR300
2P 230 30 8 CDB6v632P
100 8 CDB6v632PR100
300 8 CDB6v632PR300
3P 400 30 12 CDB6v633P
100 12 CDB6v633PR100
300 12 CDB6v633PR300
3P+N 30 14 CDB6v633N
100 14 CDB6v633NR100
300 14 CDB6v633NR300
4P 30 16 CDB6v634P
100 16 CDB6v634PR100
300 16 CDB6v634PR300
034
Final
Distribution
Technical Data
CDB6v Residual Current Protection Module
Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA
Mechanical
Features
Connection
Installation
Electrical
Features
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Rated Insulation Voltage
Breaking Capacity
Sensitivity
Tripping Indication
Manual Control
IEC61009-1
AC
1P+N, 2P, 3P, 3P+N, 4P
V32 In≤32A V63 In≤63A
230/400V AC
500V
after CDB6s assembled with
reference to CDB6s parameters
30,100,300mA
On CDB6v is a residual opening
current indication, which distinguish
residual current from other faults
Manual control:allows for two kinds of reset
CDB6v resets at the same time with breaker
CDB6v resets before breaker
“G” products offer
overvoltage protection
Electrical Durability
Mechanical Durability
Protection Degree
Tropicaliation
Ambient Temperature
2000 times(In≤25A) 1000times(In>25A)
2000 times
IP20
treatrment 2
-5°C ~ +40°C
Rate
current(A)
V32
V63
M4
M5
2.2
2.5
3.0
4.5
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
-Up to 16mm2
cables(V32)
-Up to 25mm2
cables(V63)
280V±5% AC,applicable to
products with 1P+N and 2P
RCBO CDB6v Residual Current Protection Module
035
Final
Distribution
CDB6v can be assembled with CDB6s to be residual current breaker overcurrent
Protection of persons against indirect contacts
Supplementary protection of persons against direct contacting
Prevention of electric-caused fire
Overvoltage protection by products marked“G”
CDB6v Residual Current Protection Module
Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA
Overall Dimensions
Assembly
+
V32
Pole V63
1P+N
2P
3P
3P+N
4P
45±0.32
63±0.37
90±0.5
99±0.5
117±0.57
54±0.37
72±0.43
108±0.57
126±0.64
144±0.72
036
Final
Distribution
3P 63
80
100
63
80
100
63
80
100
30
30
30
100
100
100
300
300
300
12 CDB2LEH3D63S
CDB2LEH3D80S
CDB2LEH3D100S
CDB2LEH3D63Y
CDB2LEH3D80Y
CDB2LEH3D100Y
CDB2LEH3D63T
CDB2LEH3D80T
CDB2LEH3D100T
CDB2LEH3C63S
CDB2LEH3C80S
CDB2LEH3C100S
CDB2LEH3C63Y
CDB2LEH3C80Y
CDB2LEH3C100Y
CDB2LEH3C63T
CDB2LEH3C80T
CDB2LEH3C100T
63
80
100
63
80
100
63
80
100
30
30
30
100
100
100
300
300
300
6 CDB2LEH1D63S
CDB2LEH1D80S
CDB2LEH1D100S
CDB2LEH1D63Y
CDB2LEH1D80Y
CDB2LEH1D100Y
CDB2LEH1D63T
CDB2LEH1D80T
CDB2LEH1D100T
CDB2LEH1C63S
CDB2LEH1C80S
CDB2LEH1C100S
CDB2LEH1C63Y
CDB2LEH1C80Y
CDB2LEH1C100Y
CDB2LEH1C63T
CDB2LEH1C80T
CDB2LEH1C100T
1P+N
63
80
100
63
80
100
63
80
100
30
30
30
100
100
100
300
300
300
9 CDB2LEH2D63S
CDB2LEH2D80S
CDB2LEH2D100S
CDB2LEH2D63Y
CDB2LEH2D80Y
CDB2LEH2D100Y
CDB2LEH2D63T
CDB2LEH2D80T
CDB2LEH2D100T
CDB2LEH2C63S
CDB2LEH2C80S
CDB2LEH2C100S
CDB2LEH2C63Y
CDB2LEH2C80Y
CDB2LEH2C100Y
CDB2LEH2C63T
CDB2LEH2C80T
CDB2LEH2C100T
2P
3P+N 63
80
100
63
80
100
63
80
100
30
30
30
100
100
100
300
300
300
12 CDB2LEH6D63S
CDB2LEH6D80S
CDB2LEH6D100S
CDB2LEH6D63Y
CDB2LEH6D80Y
CDB2LEH6D100Y
CDB2LEH6D63T
CDB2LEH6D80T
CDB2LEH6D100T
CDB2LEH6C63S
CDB2LEH6C80S
CDB2LEH6C100S
CDB2LEH6C63Y
CDB2LEH6C80Y
CDB2LEH6C100Y
CDB2LEH6C63T
CDB2LEH6C80T
CDB2LEH6C100T
Type Width
Reference
C curve
Rating
(A)
Sensitivity
(mA) D curve
Order Information
Function CDB2LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
CDB2LE Residual Current Operated Circuit Breaker
Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA
Note: Width refers to multiple of 9mm .
037
Final
Distribution
CDB2LE Residual Current Operated Circuit Breaker
4P 63
80
100
63
80
100
63
80
100
30
30
30
100
100
100
300
300
300
15 CDB2LEH4D63S
CDB2LEH4D80S
CDB2LEH4D100S
CDB2LEH4D63Y
CDB2LEH4D80Y
CDB2LEH4D100Y
CDB2LEH4D63T
CDB2LEH4D80T
CDB2LEH4D100T
CDB2LEH4C63S
CDB2LEH4C80S
CDB2LEH4C100S
CDB2LEH4C63Y
CDB2LEH4C80Y
CDB2LEH4C100Y
CDB2LEH4C63T
CDB2LEH4C80T
CDB2LEH4C100T
Note: Width refers to multiple of 9mm .
Technical Data
Type Width
Reference
C curve
Rating
(A)
Sensitivity
(mA) D curve
Order Information
Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA
Electrical
Features
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage
Breaking Capacity Ui
Sensitivity
IEC60947-2
AC
1P+N,2P,3P,3P+N,4P
63,80,100A
230V for 1P+N; 400V for 2P/3P/3P+N/4P
500V
10KA
30,100,300mA
RCBO CDB2LE Residual Current Operated Circuit Breaker
Tripping Curve ( see following tripping curve pictures)
C curve:the magnetic release operated between 5 and 10 In
D curve:the magnetic release operated between 10 and 14 In
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
Contact Accessory:
Shunt -trip Release:
OF
MX+OF
Rate
current(A)
63-100 M7 4 5.5
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
Up to 50mm2
cables
1500 times
8500 times
2
treatment 2
-5°C ~ +40°C
Mechanical
Features
Connection
Installation
Accessories
038
Final
Distribution
CDB2LE Residual Current Operated Circuit Breaker
Overall Dimensions
Accessories
Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA
Tripping Curve
MX+OF OF CDB2LE
039
Final
Distribution
CDB6pLEResidualCurrentOperatedCircuitBreaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA
RCBO CDB6pLE Residual Current Operated Circuit Breaker
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10 In
Connection
Installation
Mounting 35mm Din-rail
Rate
current(A)
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
6-40 M5 2.5 4.5
IEC61009-1
AC
1P+N
6,10,16,20,25,32,40A
230V AC
500V
4.5KA
30mA
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
Protection Degree
Tropicalization
Ambient Temperature
2000 times
4000 times
2
treatment 2
-5℃~+40℃
2
Up to 25mm cables
Function CDB6pLE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contacts
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
Type
1P+N
Width
(mm)
36
Rating(A)
6
10
16
20
25
32
40
CDB6pLEC6
CDB6pLEC10
CDB6pLEC16
CDB6pLEC20
CDB6pLEC25
CDB6pLEC32
CDB6pLEC40
Reference
C curve
Order Information
Technical Data
Mechanical
Features
Electrical
Features
Electrical Durability
Mechanical Durability
CB
Certification
040
Final
Distribution
Overall Dimensions
Tripping Curve
CDB6pLE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA
CDB6pLE Residual Current Operated Circuit Breaker
041
Final
Distribution
Function
CDB3LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA
CDB3LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
Type
1P+N
Width
(mm)
36
Rating(A)
6
10
16
20
25
32
40
CDB3LEL5C6S
CDB3LEL5C10S
CDB3LEL5C16S
CDB3LEL5C20S
CDB3LEL5C25S
CDB3LEL5C32S
CDB3LEL5C40S
Reference
C curve
Order Information
Technical Data
Mechanical
Features
Rate
current(A)
6-40 M5 2.5 4.5
Screw Rated Torque
(Nm)
Limiting Torque
(Nm)
Connection
Installation
Mounting
Electrical
Features
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature
2000 times
2000 times
2
treatment 2
-5°C ~ +40°C
IEC61009-1
AC
1P+N
6,10,16,20,25,32,40A
230V AC
500V
4.5KA
30mA
CDB3LE Residual Current Operated Circuit Breaker
Tripping Curve (see following tripping curve pictures)
Up to 16mm2
cables
35mm Din-rail
C curve:the magnetic release operates between 5 and 10 In
RCBO
042
Final
Distribution
Overall Dimensions
Tripping Curve
CDB3LE Residual Current Operated Circuit Breaker
Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA
043
Final
Distribution
Standard:IEC61009-1
Breaking Capacity:6000A
Sensitivity:30mA
CDL6SPResidual Current Operated Circuit Breaker
Order Information
Technical information
Poles Rating (A) Sensitivity
Reference
B Curve C Curve
1P+N 6 30mA CDL6SPN5B6S CDL6SPN5C6S
10 30mA CDL6SPN5B10S CDL6SPN5C10S
16 30mA CDL6SPN5B16S CDL6SPN5C16S
20 30mA CDL6SPN5B20S CDL6SPN5C20S
25 30mA CDL6SPN5B25S CDL6SPN5C25S
32 30mA CDL6SPN5B32S CDL6SPN5C32S
40 30mA CDL6SPN5B40S CDL6SPN5C40S
Function CDL6SP Single phase residual current operated circuit breaker can offer earth leakage
protection. Usually it can be used with CDB6S.
Standard IEC61009
Breaking Capacity 6KA
Poles 1P+N
Rated Current 6,10,16,20,25,32,40A
Rated Voltage 230VAC
Rated Tripping Current 10mA
Residual Current off time ≤0.1s
Characteristic B.C
Electrical endurance 10000
Mechanical endurance 20000
Protection degree ﹣25℃~40℃
Connection terminal
Flexible conductor 16mm
2
Rigid conductor 25mm
2
Type of terminal Lug type and Pin type
Overall Dimensions
044
Final
Distribution
CDB6VR
Residual Current Operated Circuit Breaker
Standard:IEC 61008-1
RCCB Type: A
,
C
A
Sensitivity: 30, 100, 300mA
Final
Distribution
Final
Distribution
CDB6VR Residual current operated circuit breakers combine the fo
llowing functions:
Protection for users against indirect contacts
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Function
Order Information
4
2P 10
63AF 30
100
300
16
DB6VR210SC
DB6VR210YC
DB6VR210TC
C
C
C
4P
30
100
300
25
C
C
C
DB6VR216SC
DB6VR216YC
DB6VR216TC
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
8
40
63
80
100
10
100AF
63AF
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
DB6VR225SC
DB6VR225YC
DB6VR225TC
DB6VR240SC
DB6VR240YC
DB6VR240TC
DB6VR263SC
DB6VR263YC
DB6VR263TC
DB6VR280SC
DB6VR280YC
DB6VR280TC
DB6VR2100SC
DB6VR2100YC
DB6VR2100TC
30
100
300
16
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
DB6VR410SC
DB6VR410YC
DB6VR410TC
30
100
300
25
C
C
C
DB6VR416SC
DB6VR416YC
DB6VR416TC
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
40
63
80
100
100AF
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
DB6VR425SC
DB6VR425YC
DB6VR425TC
DB6VR440SC
DB6VR440YC
DB6VR440TC
DB6VR463SC
DB6VR463YC
DB6VR463TC
DB6VR480SC
DB6VR480YC
DB6VR480TC
DB6VR4100SC
DB6VR4100YC
DB6VR4100TC
DB6VR210SA
DB6VR210YA
DB6VR210TA
DB6VR216SA
DB6VR216YA
DB6VR216TA
DB6VR225SA
DB6VR225YA
DB6VR225TA
DB6VR240SA
DB6VR240YA
DB6VR240TA
DB6VR263SA
DB6VR263YA
DB6VR263TA
DB6VR280SA
DB6VR280YA
DB6VR280TA
DB6VR2100SA
DB6VR2100YA
DB6VR2100TA
DB6VR410SA
DB6VR410YA
DB6VR410TA
DB6VR416SA
DB6VR416YA
DB6VR416TA
DB6VR425SA
DB6VR425YA
DB6VR425TA
DB6VR440SA
DB6VR440YA
DB6VR440TA
DB6VR463SA
DB6VR463YA
DB6VR463TA
DB6VR480SA
DB6VR480YA
DB6VR480TA
DB6VR4100SA
DB6VR4100YA
DB6VR4100TA
045
Final
Distribution
Standard: IEC 61008-1
RCCB Type: AC,A
Sensitivity: 30, 100, 300mA
CDB6VR
Residual Current Operated Circuit Breaker
Overall Dimensions
RCCB
Connection
Installation
Mounting 35mm Din-rail
Standard
Certification
Type
IEC 61008-1
TUV,CE,CB
AC,A
2P、4P
230/400V AC
500V
30,100,300mA
no
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Sensitivity
1000 times
2000 times
Tripping Indication
Fault Curren Indicator Mechanical indication in the front
Protection Degree 2
Tropicalization
Up to 25mm
2
cables(In>63A)
Up to 35mm
2
Treatment 2
Ambient Temperature -25 ~+40
Screw
Rate
current(A)
Rated Torque
(Nm)
Limiting Torque
(Nm)
25-100 M5 2.0 4.5
No need
Overload or Short
Circuit Protection
Instantaneous, rated residual
operated current, unadjustable
10,16,25,32,40,63,80,
Mechanical
Features
Electrical
Features
Power source
Auxilary
A
y
Mechanical Durability
Electrical Durabilit
,
100
CDB6VR-63 CDB6VR-100
CDB6VR Residual Current Operated Circuit Breaker
4P
2P
36
61.7
72
70±0.6
43.5±0.6
5.5
35.4
45
78.5
046
Final
Distribution
The sketch map of installation with breaker
SD OF Breaker MX+OF
SD OF MX+OF
Accessories
CDB6,CDB6LE
Order Information
type Width(mm) Voltage(V) Reference
OF 9 CDB6OF
SD 9 CDB6SD
MX+OF 18
18
18
18
18
18
18
CDB6MX110
CDB6MX130
CDB6MX230
CDB6MX400
CDB6MX12
CDB6MX24
CDB6MX48
AC 110V
AC 130V
AC 230V
AC 400V
AC/DC 12V
AC/DC 24V
AC/DC 48V
Connection: 1-4mm2
cables
Remote Control Auxiliaries
OF contact auxiliary
Indicate ON or OFF state of the breaker
Basic type of auxiliary contact:1NO+1NC
Connection: 1-4mm2
cables
SD fault-indicating switch
Indicator on the front to show fault trip
Basic type of auxiliary contact:1NO+1NC
Connection: 1-4mm2
cables
MX+OF shunt trip release
Indicate ON or OFF state of the breaker
Make the assembled breaker trip once got signal
Basic type of auxiliary contact:1NO+1NC
Tripping Device
OF, SD must be assembled on the left ,one auxiliary only
Each time only one auxiliary accepted in the left of MCB
MX+OF must be assembled on the right, one MX+OF only
CDB6LE can't assemble MX+OF
Introductions
Sent out fault signal on the front when breaking down
MX+OF must be assembled on the right, one MX+OF only
047
Final
Distribution
CDB9,CDB9LE
Accessoriess
The sketch map of installation with breakers
Remote Control Auxiliaries
Tripping Device Introductions
■ OF contact auxiliary
● Indicate ON or OFF state of the breaker
● Basic type of auxiliary contact: 1NO+INC
■ SD fault-indicating switch
● Sent out fault signal on the font when breaking down
● Indicator on the front to show fault trip
● Basic type of auxiliary contact: 1NO+1NC
■ MX+OF shunt trip release
● Indicate ON or OFF state of the breaker
● Without tools ,directly installed on the left of MCB
■ Without tools ,direct installed on the left of MCB
■ Each MCB maximum assembles 3 control auxiliaries(OF or SD)
Type Width(mm) Voltage(V) Reference
9 CDB963OF
9 CDB963SD
18 AC/DC 12/24V CDB963MX24
18 AC/DC 48V CDB963MX48
18
AC 100-415V
DC 110-130V
CDB963MX415
Order Information
Accessories
048
Final
Distribution
Accessories
CDB6s
type Width(mm) Voltage(V) Reference
OF 9 CDB6sOF
SD 9 CDB6sSD
The sketch map of installation with breakers
SD fault-indicating switch
Sent out fault signal when breaking down
Indicator on the front to show fault trip
Basic type of auxiliary contact:1NO+1NC
Connection:1-4mm2
cables
OF,SD must be assembled on the left ,one auxiliary only
Each time only one auxiliary accepted in the left of MCB
MX+OF must be assembled on the right, one MX+OF only
CDB6s can't assemble MX+OF while assembled with CDB6v
SD OF MX+OF
CDB6s
Order Information
Introductions
OF contact auxiliary
Indicate ON or OFF state of the breaker
Basic type of auxiliary contact:1NO+1NC
Connection:1-4mm2
cables
MX+OF shunt trip release
Indicate ON or OFF state of the breaker
Make the assembled breaker trip while given signal
Basic type of auxiliary contact:1NO+1NC
Connection:1-4mm2
cables
Tripping Device
Remote Control Auxiliaries
MX+OF 1 CDB6sMX24
CDB6sMX48
CDB6sMX110
CDB6sMX230
18
18
18
18 AC230-400V
AC/DC12-24V
AC/DC24-48V
AC110-127V
MX+OF must be assembled on the right, one MX+OF only
049
Final
Distribution
CDB2,CDB2LE
The sketch map of installation with breakers
MX+OF OF Breaker
OF contact auxiliary
Indicate ON or OFF state of the breaker
Basic type of auxiliary contact:2NO+2NC
Connection: 1-4mm2
cables
MX+OF shunt trip release
Indicate ON or OFF state of the breaker
Make the assembled breaker trip once got signal
Basic type of auxiliary contact:1NO+1NC
Connection: 1-4mm2
cables
Tripping Device
Remote Control Auxiliaries
MX+OF, OF must be assembled on the left
Each time only one auxiliary accepted in the left of MCB
Introductions
Type Width(mm) Description Reference
OF 18 1NO 1NC CDB2OF11
18 2NO 2NC CDB2OF22
MX+OF 18 CDB2MX24
18 AC48V~130V DC48V CDB2MX48
18 AC230V-400V DC110V-130V CDB2MX230
Order Information
AC/DC24V
Accessories
OF must be assembled on the left
050
Final
Distribution
Technical Data
Busbar
A
A
A
A
A
A
A
A
Order Information
PIN-TYPE
U-TYPE
Terminal Adaptor CBBA805
1
2
3
4
1
2
3
4
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
10
16
10
16
10
16
10
16
10
16
10
16
10
16
10
16
63
80
63
80
63
80
63
80
63
80
63
80
63
80
63
80
Type
Type Reference Dimension(mm)
Pole
Thickness
of pin
(mm)
Section
cross
(mm2
)
Max.
current(A)
End feed-in
A Reference
Length Dimension(mm)
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
1m
CBB16315P
CBB18015P
CBB26315P
CBB28015P
CBB36315P
CBB38015P
CBB46315P
CBB48015P
CBB16315F
CBB18015F
CBB26315F
CBB28015F
CBB36315F
CBB38015F
CBB46315F
CBB48015F
Standard
Material of busbar
Material of insulation
Short-circuit strength
Nominal voltage
Operating voltage
Surge voltage
Clima stability
IEC 60664
E-CU-F25
PVC
50kA
415V
Max 500V
4kV
IEC 60068-2
7
11
7
11
7
11
7
11
7
11
7
11
7
11
7
11
.
.
.
Accessories
051
Final
Distribution
CDCH8P Modular Contactor
Standard: IEC 61095
Function
Order Information
CDCH8P Modular Contactor provide:
Automatic control on equipment in buildings
Switch on or Switch off lighting or other equipments
Pole Reference
Current (A) Contacts
2P 16 2NO CDCH8P16220
1NO 1NC CDCH8P16211
20 2NO CDCH8P20220
1NO 1NC CDCH8P20211
25 2NO CDCH8P25220
1NO 1NC CDCH8P25211
32 2NO CDCH8P32220
2NC CDCH8P32202
1NO 1NC CDCH8P32211
40 2NO CDCH8P40220
2NC CDCH8P40202
1NO 1NC CDCH8P40211
63 2NO CDCH8P63220
2NC CDCH8P63202
1NO 1NC CDCH8P63211
4P 16 4NO CDCH8P16440
4NC CDCH8P16404
2NO 2NC CDCH8P16422
3NO 1NC CDCH8P16431
20 4NO CDCH8P20440
4NC CDCH8P20404
2NO 2NC CDCH8P20422
3NO 1NC CDCH8P20431
25 4NO CDCH8P25440
4NC CDCH8P25404
2NO 2NC CDCH8P25422
3NO 1NC CDCH8P25431
32 4NO CDCH8P32440
4NC CDCH8P32404
2NO 2NC CDCH8P32422
3NO 1NC CDCH8P32431
40 4NO CDCH8P40440
4NC CDCH8P40404
2NO 2NC CDCH8P40422
3NO 1NC CDCH8P40431
63 4NO CDCH8P63440
4NC CDCH8P63404
2NO 2NC CDCH8P63422
3NO 1NC CDCH8P63431
052
Final
Distribution
Technical information
Standard IEC 61095
Ambient Temperature ﹣5℃~40℃
Rated Voltage Ue 230V AC
Rated Insulation Voltage Ui 500V AC
Operation Time ≥30000 times
Coil Voltage (Us) 220/230V AC
Type AC-7a AC-7b
Rated Current (Ie) 20A/25A/32A/40A/63A 7A/8.5A/12A/15A/25A
Rated Power
4kW/5.4kW/6.5kW/
8.4kW/13kW
1.2kW/1.5kW/1.9kW/
2.4kW/3.8kW
Operation Frequency 1200times/h 30time/h
Marking & Breaking
Capacity
1.5Ie 8Ie
CDCH8P Modular Contactor
Standard: IEC 61095
053
Final
Distribution
17.5
35
35
Overall Dimensions
CDCH8P-2P, 16-25A
CDCH8P-2P, 32-63A
CDCH8P-4P, 16-25A
CDCH8P-4P, 32-63A
CDCH8P Modular Contactor
Standard: IEC 61095
054
Final
Distribution
CDRT8 Time Relay
Standard:IEC 60947.5
Order Information
Technical Data
CDRT8 Time Relay provide:
Disconnect Delay
Connect Delay
Limit delay time Delay type Reference
CDRT810B
CDRT8120B
CDRT8480A
power delay
power delay
off delay
10
120
480
480
power delay CDRT8480B
Standard
Rated Voltage Ue
Rated Current(le)
Delay Type
Timing Range
Contact Type
Contact Number
Rated Control Supply Voltage(Us)
Operating Voltage Range
Rated Wattage
Insulation Resistance
Insulation Strength
Connection
Limit Delay Time
Conventional Thermal Current(l )
CDRT8 Time Relay
Building Control Command Devices
up to 1mm cables
2
To each:AC 1760V 5s
Disconnect between the
contact position:AC 1000V 1min
<1W
>
85%-110%Us
230V AC
1
Normally open contact
8A
10s 120s 480s
Off dalay
Power delay
5A
230V AC
th
Electrical Durability 30000 times
IEC 60947.5
Function
055
Final
Distribution
CDRT8 Time Relay
Standard:IEC 60947.5
Wiring Diagram
Overall Dimensions
19max
056
Final
Distribution
Function
CDY1 Surge Protective Devices
	
Standard: IEC61643
CDY1 surge protective devices provide:
Applicable to household appliances and the like to offer protection
When there is an over-voltage caused by either lightning strike or operation in the circuit
Order Information
Imax
(kA)
Uc
(V)
Up
(kV)
Reference
1P 2P 3P 4P 1P+N 3P+N
20 275 1.3 CDY1201275 CDY1202275 CDY1203275 CDY1204275 CDY1205275 CDY1206275
385 1.5 CDY1201385 CDY1202385 CDY1203385 CDY1204385 CDY1205385 CDY1206385
420 1.8 CDY1201420 CDY1202420 CDY1203420 CDY1204420 CDY1205420 CDY1206420
40 275 1.5 CDY1401275 CDY1402275 CDY1403275 CDY1404275 CDY1405275 CDY1406275
385 1.8 CDY1401385 CDY1402385 CDY1403385 CDY1404385 CDY1405385 CDY1406385
420 2.0 CDY1401420 CDY1402420 CDY1403420 CDY1404420 CDY1405420 CDY1406420
60 275 1.8 CDY1601275 CDY1602275 CDY1603275 CDY1604275 CDY1605275 CDY1606275
385 2.2 CDY1601385 CDY1602385 CDY1603385 CDY1604385 CDY1605385 CDY1606385
420 2.5 CDY1601420 CDY1602420 CDY1603420 CDY1604420 CDY1605420 CDY1606420
80 275 2.0 CDY1801275 CDY1802275 CDY1803275 CDY1804275 CDY1805275 CDY1806275
385 2.2 CDY1801385 CDY1802385 CDY1803385 CDY1804385 CDY1805385 CDY1806385
420 2.5 CDY1801420 CDY1802420 CDY1803420 CDY1804420 CDY1805420 CDY1806420
100 275 2.2 CDY11001275 CDY11002275 CDY11003275 CDY11004275 CDY11005275 CDY11006275
385 2.5 CDY11001385 CDY11002385 CDY11003385 CDY11004385 CDY11005385 CDY11006385
420 2.5 CDY11001420 CDY11002420 CDY11003420 CDY11004420 CDY11005420 CDY11006420
057
Final
Distribution
CDY1 Surge Protective Devices
Standard: IEC61643
Overall Dimensions
Technical Data
CDY1-80 CDY1-100
CDY1-60
CDY1-40
CDY1-20
1P, 1P+N, 2P, 3P, 3P+N, 4P
20
40
30
60
40
80
50
100
Type
Pole	
Nominal discharge
current In(8/20us) kA
Maximum discharge current
Imax(8/20us) kA	
Maximum continuous
operational voltage Uc V	
Protection level Up kV	
Leakage current
(75%Uc 1mA) uA	
Response time ns
≤20
≤25
275
1.3
385
1.5
420
1.8
275
1.5
420
2.0
275
1.8
420
2.5
385
2.2
275
2.0
420
2.5
385
2.2
275
2.2
420
2.5
385
2.5
385
1.8
Standard: IEC 61643
Certification: SEMKO, CB
10
20
058
Final
Distribution
Function
Order Information
CDPZ50 Series Consumer Box
Standard: IEC60439-1 IEC60670
CDPZ50 series Consumer Box provide:
Protection against overload
Protection against over voltage
Protection against leakage
Material Installation No.of loop Reference
Metal box&Plastic Cover Surface installation 6 CDPZ50M6
8 CDPZ50M8
12 CDPZ50M1 2
16 CDPZ50M1 6
20 CDPZ50M20
24 CDPZ50M24
Flush installation 6 CDPZ50R6
8 CDPZ50R8
12 CDPZ50R1 2
16 CDPZ50R1 6
20 CDPZ50R20
24 CDPZ50R24
Material Installation No.of loop Reference
Full Plastic 4 CDPZ50PM41P30F
6 CDPZ50PM61P30F
8 CDPZ50PM8IP30F
12 CDPZ50PM121P30F
15 CDPZ50PM151P30F
18 CDPZ50PM18IP30F
24 CDPZ50PM24IP30F
36 CDPZ50PM36IP30F
4 CDPZ50PR41P30F
6 CDPZ50PR61P30F
8 CDPZ50PR8IP30F
12 CDPZ50PR121P30F
15 CDPZ50PR151P30F
18 CDPZ50PR18IP30F
24 CDPZ50PR24IP30F
36 CDPZ50PR36IP30F
Full Plastic Surface installation
Non
4 CDPZ50PM41P30NF
6 CDPZ50PM61P30NF
8 CDPZ50PM8IP30NF
12 CDPZ50PM121P30NF
15 CDPZ50PM151P30NF
18 CDPZ50PM18IP30NF
24 CDPZ50PM24IP30NF
36 CDPZ50PM36IP30NF
Flush installation
Surface installation
Flush installation
4 CDPZS0PR41P30NF
6 CDPZS0PR61P30NF
8 CDPZ50PR8IP30NF
12 CDPZ50PR121P30NF
15 CDPZ50PR151P30NF
18 CDPZ50PR18IP30NF
24 CDPZ50PR24IP30NF
36 CDPZ50PR36IP30NF
059
Final
Distribution
CDPZ50 Series Consumer Box
Standard: IEC60439-1 IEC60670
Unit:mm
Overall Dimensions
CDPZ50
Surface installation
A
Thickness
C
90
90
90
90
90
90
B
200
200
200
200
200
364
Flush installation
A
163
199
272
343
413
282
B
220
220
220
220
220
383
171
207
279
351
423
303
6
8
12
16
20
24
Metal box&Plastic
Cover
Technical Data
Full Plastic
Optional
Material
Fire-resistancy Fire-resistancy
Protection grade
Rated operation voltage
Rated insulated voltage
Rated operating current
Withstand current
IP30
230/400V
500V
100A
6kA
Box:Metal, Cover:Plastic
CDPZ50 CDPZ50P
Type
Surface installation
Flush installation
CDPZ50P
D
E
F
H
I
A
B
C C1
Flush installation
Surface installation
Full plastic
Loop
number
060
Final
Distribution
Order Information
Function
JXF Metal Enclosure
Standard: EN60529
JXF Metal Enclosure provide:
Control, monitering, measurement and protection for the electric power loops and main power
controlling equipment.
Type
Thickness of
iron charge(mm)
Dimension(mm)
Lock Reference
Overall Installation Mounting
H W D H1 B1 H6 B6 Thick
JXF一2520/14 lP43 Improved 1.0 250 200 140 290 150 170 158 1.0 1 JXF252014B
JXF一3025/14 lP43 Improved 1.0 300 250 140 340 200 220 208 1.0 1 JXF302514B
JXF一3025/18 lP43 Improved 1.0 300 250 180 340 200 220 208 1.0 1 JXF302518B
JXF一3030/14 lP43 Improved 1.0 300 300 140 340 250 220 258 1.0 1 JXF303014B
JXF一3030/18 lP43 Improved 1.0 300 300 200 340 250 220 258 1.0 1 JXF303018B
JXF一4030/14 lP43 Improved 1.0 400 300 140 440 250 320 258 1.0 1 JXF403014B
JXF一4030/20 lP43 Improved 1.0 400 300 200 440 250 320 258 1.0 1 JXF403020B
JXF一5040/14 lP43 Improved 1.0 500 400 250 540 350 420 358 1.0 2 JXF504014B
JXF一5040/20 lP43 Improved 1.0 500 400 140 540 350 420 358 1.0 2 JXF504020B
JXF一5040/25 lP43 Improved 1.0 500 400 200 540 350 420 358 1.0 2 JXF504025B
JXF一6040/14 lP43 Improved 1.2 600 400 250 640 350 520 358 1.2 2 JXF604014B
JXF一6040/20 lP43 Improved 1.2 600 400 140 640 350 520 358 1.2 2 JXF604020B
JXF一6040/25 lP43 Improved 1.2 600 400 200 640 350 520 358 1.2 2 JXF604025B
JXF一6050/14 lP43 Improved 1.2 600 500 250 640 450 520 458 1.2 2 JXF605014B
JXF一6050/20 lP43 Improved 1.2 600 500 140 640 450 520 458 1.2 2 JXF605020B
JXF一6050/25 lP43 Improved 1.2 600 500 160 640 450 520 458 1.2 2 JXF605025B
JXF一7050/16 lP43 Improved 1.2 700 500 200 740 450 620 458 1.2 2 JXF705016B
JXF一7050/20 lP43 Improved 1.2 700 500 250 740 450 620 458 1.2 2 JXF705020B
JXF一7050/25 lP43 Improved 1.2 700 500 200 740 450 620 458 1.2 2 JXF705025B
JXF一8060/20 lP43 Improved 1.5 800 600 250 840 550 720 558 1.5 2 JXF806020B
JXF一8060/25 lP43 Improved 1.5 800 600 250 840 550 720 558 1.5 2 JXF806025B
JXF一10080/20 lP43 Improved 1.5 1000 800 200 1040 750 920 758 1.5 2 JXFl008020B
JXF一10080/25 lP43 Improved 1.5 1000 800 250 1040 750 920 758 1.5 2 JXFl008025B
JXF一10080/30 lP43 Improved 1.5 1000 800 300 1040 750 920 758 1.5 2 JXFl008030B
JXF一2520/14 IP54 1.2 250 200 140 320 150 215 148 2.0 1 JXF252014Q
JXF一3025/14 IP54 1.2 300 250 140 370 200 265 198 2.0 1 JXF302514Q
JXF一3025/18 IP54 1.2 300 250 370 200 265 265 198 2.0 1 JXF302518Q
JXF一3030/14 IP54 1.2 300 300 370 250 265 265 248 2.0 1 JXF303014Q
JXF一3030/1 8 IP54 1.2 300 300 370 250 265 265 248 2.0 1 JXF30301 8Q
JXF一4030/14 IP54 1.2 400 300 470 250 365 365 248 2.0 1 JXF403014Q
JXF一4030/20 IP54 1.2 400 300 470 250 365 365 248 2.0 1 JXF403020Q
JXF一5040/14 IP54 1.2 500 400 570 350 465 465 348 2.0 2 JXF504014Q
JXF一5040/20 IP54 1.2 500 400 570 350 465 465 348 2.0 2 JXF504020Q
JXF一5040/25 IP54 1.2 500 400 570 350 465 465 348 2.0 2 JXF504025Q
JXF一6040/14 IP54 1.5 600 400 670 350 565 565 348 2.0 2 JXF604014Q
JXF一6040/20 IP54 1.5 600 400 670 350 565 565 348 2.0 2 JXF604020Q
JXF一6040/25 IP54 1.5 600 400 670 350 565 565 348 2.0 2 JXF604025Q
JXF一6050/14 IP54 1.5 600 500 670 450 565 565 448 2.0 2 JXF605014Q
JXF一6050/20 IP54 1.5 600 500 670 450 565 565 448 2.0 2 JXF605020Q
JXF一6050/25 IP54 1.5 600 500 670 450 565 565 448 2.0 2 JXF605025Q
JXF一7050/1 6 IP54 1.5 700 500 770 450 665 665 448 2.0 2 JXF705016Q
JXF一7050/20 IP54 1.5 700 500 770 450 665 665 448 2.0 2 JXF705020Q
JXF一7050/25 IP54 1.5 700 500 770 450 665 665 448 2.0 2 JXF705025Q
JXF一8060/20 IP54 1.5 800 600 870 550 765 765 548 2.0 2 JXF806020Q
JXF一8060/25 IP54 1.5 800 600 870 550 765 765 548 2.0 2 JXF806025Q
JXF一10080/20 IP54 1.5 1000 800 1070 750 965 965 748 2.0 2 JXF1008020Q
JXF一10080/25 IP54 1.5 1000 800 1070 750 965 965 748 2.0 2 JXF1008025Q
JXF一10080/30 IP54 1.5 1000 800 1070 750 965 965 748 2.0 2 JXF1008030Q
061
Final
Distribution
Technical Data
Unit: mm
Overall Dimensions
x
handle lock
hinge
door
bo
sealing rubber gasket
sealing rubber gasket
wall fixing bracket
JXF Metal Enclosure
Standard: EN60529
Protection grade
Standard:
Certificate
Rated voltage
Rated insulated voltage
Rated operating current
Withstand current
Sheet thickness
Mounting plate thickness
Hinge
Sealing rubber gasket
Cable gland
Type JXF IP43 Improved
IP43
EN60529
CE
220/400V
660V
400A
15kA
1.0~1.5mm
1.0~1.5mm
Enhanced
Black rubber gasket
bottom only
IP54
IP54
EN60529
CE
220/400V
660V
400A
15kA
1.2-1.5mm
2.0mm
Enhanced
Black rubber gasket
bottom only
062
Low-voltage
Distribution
Molded Case Circuit Breaker & Air Circuit Breaker
Product Overview
063 086
Current: 16-800A
Breaking Capacity: L,S,M,T
CDM6S CDM6L
Current: 40-630A
Breaking Capacity: L,M
103 112
CDM1 CDM1LE
Current: 10-1250A
Breaking Capacity: L,M
Current: 16-400A
Breaking Capacity: L,M
120 169
CDW9 CDW6
Current: 630~6300A
Voltage: 400/415V, 690V
Current: 200~6300A
Voltage: 400V
Molded Case Circuit Breaker
Air Circuit Breaker
063
Low-voltage
Distribution
Type Pole In A
Fixed Thermal Magnetic Thermo-adjustable
L-type S-Type M-type T-Type M-type T-Type
CDM6s-63 3 10
16
20
25
32
40
50
63
4 10
16
20
25
32
40
50
63
CDM6s-100 3 16
20
25
32
40
50
63
80
100
4 16
25
40
63
100
CDM6s-250 3 100
125
160
180
200
225
250
4 125
160
200
250
Order Information
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
CDM6s063L0103XXXF
CDM6s063L0163XXXF
CDM6s063L0203XXXF
CDM6s063L0253XXXF
CDM6s063L0323XXXF
CDM6s063L0403XXXF
CDM6s063L0503XXXF
CDM6s063L0633XXXF
-
-
-
-
-
-
-
-
CDM6s100L0163XXXF
CDM6s100L0203XXXF
CDM6s100L0253XXXF
CDM6s100L0323XXXF
CDM6s100L0403XXXF
CDM6s100L0503XXXF
CDM6s100L0633XXXF
CDM6s100L0803XXXF
CDM6s100L1003XXXF
-
-
-
-
-
CDM6s250L1003XXXF
CDM6s250L1253XXXF
CDM6s250L1603XXXF
CDM6s250L1803XXXF
CDM6s250L2003XXXF
CDM6s250L2253XXXF
CDM6s250L2503XXXF
-
-
-
-
CDM6s063S0103XXXF
CDM6s063S0163XXXF
CDM6s063S0203XXXF
CDM6s063S0253XXXF
CDM6s063S0323XXXF
CDM6s063S0403XXXF
CDM6s063S0503XXXF
CDM6s063S0633XXXF
-
-
-
-
-
-
-
-
CDM6s100S0163XXXF
CDM6s100S0203XXXF
CDM6s100S0253XXXF
CDM6s100S0323XXXF
CDM6s100S0403XXXF
CDM6s100S0503XXXF
CDM6s100S0633XXXF
CDM6s100S0803XXXF
CDM6s100S1003XXXF
-
-
-
-
-
CDM6s250S1003XXXF
CDM6s250S1253XXXF
CDM6s250S1603XXXF
CDM6s250S1803XXXF
CDM6s250S2003XXXF
CDM6s250S2253XXXF
CDM6s250S2503XXXF
-
-
-
-
CDM6s063M0103XXXF
CDM6s063M0163XXXF
CDM6s063M0203XXXF
CDM6s063M0253XXXF
CDM6s063M0323XXXF
CDM6s063M0403XXXF
CDM6s063M0503XXXF
CDM6s063M0633XXXF
CDM6s063M0104XXXF
CDM6s063M0164XXXF
CDM6s063M0204XXXF
CDM6s063M0254XXXF
CDM6s063M0324XXXF
CDM6s063M0404XXXF
CDM6s063M0504XXXF
CDM6s063M0634XXXF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CDM6s063T0103XXXF
CDM6s063T0163XXXF
CDM6s063T0203XXXF
CDM6s063T0253XXXF
CDM6s063T0323XXXF
CDM6s063T0403XXXF
CDM6s063T0503XXXF
CDM6s063T0633XXXF
CDM6s063T0104XXXF
CDM6s063T0164XXXF
CDM6s063T0204XXXF
CDM6s063T0254XXXF
CDM6s063T0324XXXF
CDM6s063T0404XXXF
CDM6s063T0504XXXF
CDM6s063T0634XXXF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CDM6s100M0163XXX3
-
CDM6s100M0253XXX3
-
CDM6s100M0403XXX3
-
CDM6s100M0633XXX3
-
CDM6s100M1003XXX3
CDM6s100M0164XXX3
CDM6s100M0254XXX3
CDM6s100M0404XXX3
CDM6s100M0634XXX3
CDM6s100M1004XXX3
-
CDM6s250M1253XXX3
CDM6s250M1603XXX3
-
CDM6s250M2003XXX3
-
CDM6s250M2503XXX3
CDM6s250M1254XXX3
CDM6s250M1604XXX3
CDM6s250M2004XXX3
CDM6s250M2504XXX3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CDM6s100T0163XXX3
-
CDM6s100T0253XXX3
-
CDM6s100T0403XXX3
-
CDM6s100T0633XXX3
-
CDM6s100T1003XXX3
CDM6s100T0164XXX3
CDM6s100T0254XXX3
CDM6s100T0404XXX3
CDM6s100T0634XXX3
CDM6s100T1004XXX3
-
CDM6s250T1253XXX3
CDM6s250T1603XXX3
-
CDM6s250T2003XXX3
-
CDM6s250T2503XXX3
CDM6s250T1254XXX3
CDM6s250T1604XXX3
CDM6s250T2004XXX3
CDM6s250T2504XXX3
064
Low-voltage
Distribution
Type Pole In A
Fixed Thermal Magnetic Thermo-adjustable
L-type S-Type M-type T-Type M-type T-Type
CDM6s-400 3 200
225
250
315
350
400
4 200
225
250
315
350
400
CDM6s-630 3 400
500
630
4 400
500
630
CDM6s-800 3 400
500
630
700
800
4 400
500
630
700
800
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
CDM6s400L2003XXXF
CDM6s400L2253XXXF
CDM6s400L2503XXXF
CDM6s400L3153XXXF
CDM6s400L3503XXXF
CDM6s400L4003XXXF
CDM6s400L2004XXXF
CDM6s400L2254XXXF
CDM6s400L2504XXXF
CDM6s400L3154XXXF
CDM6s400L3504XXXF
CDM6s400L4004XXXF
CDM6s630L4003XXXF
CDM6s630L5003XXXF
CDM6s630L6303XXXF
CDM6s630L4004XXXF
CDM6s630L5004XXXF
CDM6s630L6304XXXF
CDM6s800L4003XXXF
CDM6s800L5003XXXF
CDM6s800L6303XXXF
CDM6s800L7003XXXF
CDM6s800L8003XXXF
CDM6s800L4004XXXF
CDM6s800L5004XXXF
CDM6s800L6304XXXF
CDM6s800L7004XXXF
CDM6s800L8004XXXF
CDM6s400S2003XXXF
CDM6s400S2253XXXF
CDM6s400S2503XXXF
CDM6s400S3153XXXF
CDM6s400S3503XXXF
CDM6s400S4003XXXF
CDM6s400S2004XXXF
CDM6s400S2254XXXF
CDM6s400S2504XXXF
CDM6s400S3154XXXF
CDM6s400S3504XXXF
CDM6s400S4004XXXF
CDM6s630S4003XXXF
CDM6s630S5003XXXF
CDM6s630S6303XXXF
CDM6s630S4004XXXF
CDM6s630S5004XXXF
CDM6s630S6304XXXF
CDM6s800S4003XXXF
CDM6s800S5003XXXF
CDM6s800S6303XXXF
CDM6s800S7003XXXF
CDM6s800S8003XXXF
CDM6s800S4004XXXF
CDM6s800S5004XXXF
CDM6s800S6304XXXF
CDM6s800S7004XXXF
CDM6s800S8004XXXF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CDM6s800M4003XXXF
CDM6s800M5003XXXF
CDM6s800M6303XXXF
CDM6s800M7003XXXF
CDM6s800M8003XXXF
CDM6s800M4004XXXF
CDM6s800M5004XXXF
CDM6s800M6304XXXF
CDM6s800M7004XXXF
CDM6s800M8004XXXF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CDM6s800T4003XXXF
CDM6s800T5003XXXF
CDM6s800T6303XXXF
CDM6s800T7003XXXF
CDM6s800T8003XXXF
CDM6s800T4004XXXF
CDM6s800T5004XXXF
CDM6s800T6304XXXF
CDM6s800T7004XXXF
CDM6s800T8004XXXF
-
-
CDM6s400M2503XXX3
-
-
CDM6s400M4003XXX3
-
-
CDM6s400M2504XXX3
-
-
CDM6s400M4004XXX3
-
CDM6s630M5003XXX3
CDM6s630M6303XXX3
-
CDM6s630M5004XXX3
CDM6s630M6304XXX3
-
-
-
-
-
-
-
-
-
-
-
-
CDM6s400T2503XXX3
-
-
CDM6s400T4003XXX3
-
-
CDM6s400T2504XXX3
-
-
CDM6s400T4004XXX3
-
CDM6s630T5003XXX3
CDM6s630T6303XXX3
-
CDM6s630T5004XXX3
CDM6s630T6304XXX3
-
-
-
-
-
-
-
-
-
-
Order Information
065
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Technical Data
Frame Size
Number of Poles
Breaking Capacity Level
3P
L S M T L S
25 18 50 30 35
M T
50 30
4P 3P 4P
Rated Ultimate Short-circuit Breaking
Capacity Icu (kA rms)
Rated Service Short-circuit Breaking
Capacity Ics (kA rms)
Mechanical Durabilities
Electrical Durabilities
On-off Cycle
shows it has this option;
means it has no this option.
See Page 74 See Page 75 See Page 76
Basic Information (IEC60947-2)
Tripping Unit
Accessory
OF
SD
Indication Accessories
Control Accessories
Connection
Spreader
Protection
Phase Barrier
Installation Information
Mounting & Connection
Rated Current (A)
MX(AC400, 230V, DC220V)
MN (AC400, 230V)
Extended Rotary Handle (Round and Square)
AC Motor Mechanism (AC400, 230V)
Mechanical Interlock
Fixed, Front Connection
Fixed, Rear Connection
Plug-in, Rear Connection
Plug-in, Front Connection
Drawer-out, Rear Connection
75% 100% 75%
S
26
100%
L
35
75%
S
26
100%
50% 100% 50% 100%
16/20//25/32/40/
50/63/80/100
100/125/160/180/
200/225/250
Fixed Thermal Magnetic
26
3P 4P
L
35
75%
S
26
100%
L
35
75% 100%
066
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Technical Data
Frame Size
Number of Poles
Breaking Capacity Level
Rated Ultimate Short-circuit Breaking
Capacity Icu (kA rms)
Rated Service Short-circuit Breaking
Capacity Ics (kA rms)
On-off Cycle
shows it has this option;
means it has no this option.
Basic Information (IEC60947-2)
Tripping Unit
Accessory
OF
SD
Indication Accessories
Control Accessories
Connection
Spreader
Protection
Phase Barrier
Installation Information
Mounting & Connection
Rated Current (A)
MX(AC400, 230V, DC220V)
MN (AC400, 230V)
Extended Rotary Handle (Round and Square)
AC Motor Mechanism (AC400, 230V)
Mechanical Interlock
Fixed, Front Connection
Fixed, Rear Connection
Plug-in, Rear Connection
Plug-in, Front Connection
Drawer-out, Rear Connection
See Page 77 See Page 78 See Page 79
Mechanical Durabilities
Electrical Durabilities
Fixed Thermal Magnetic
S
L S L
50 30 50 30
3P 4P
50%
200/225/250/315/
350/400
100% 50% 100%
S
L S L
50 30 50 30
3P 4P
50% 100% 50% 100%
T
L S M
50 30 70 40
3P 4P
50% 100% 50% 100%
T
L S M
50 30 70 40
50% 100% 50% 100%
067
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Technical Data
Frame Size
Number of Poles
Breaking Capacity Level
Rated Ultimate Short-circuit Breaking
Capacity Icu (kA rms)
Rated Service Short-circuit Breaking
Capacity Ics (kA rms)
Mechanical Endurance
Electrical Endurance
On-off Cycle
shows it has this option;
means it has no this option.
See Page 75 See Page 77 See Page 78
Basic Information (IEC60947-2)
Tripping Unit
Accessory
OF
SD
Indication Accessories
Control Accessories
Connection
Spreader
Protection
Phase Barrier
Installation Information
Mounting & Connection
Rated Current (A)
Thermo-adjustable Setting (Ir)
MX(AC400, 230V, DC220V)
MN (AC400, 230V)
Extended Rotary Handle (Round and Square)
AC Motor Mechanism (AC400, 230V)
Mechanical Interlock
Fixed, Front Connection
Fixed, Rear Connection
Plug-in, Rear Connection
Plug-in, Front Connection
Drawer-out, Rear Connection
Thermo-adjustable
16/25/40/63/100 125/160/200/250 250/400 500/630
See Page 76
T
M T M
50 30 50 30
3P 4P
50% 100% 50% 100%
T
M T M
50 30 50 30
3P 4P
50% 100% 50% 100%
T
M T M
70 40 70 40
3P 4P
50% 100% 50% 100%
T
M T M
70 40 70 40
3P 4P
50% 100% 50% 100%
068
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Basic Technical Data
Complete Functions and Accessories
Rated Insulation Voltage Ui: AC 800V (Frame 63AF: AC 690V)
Rated Impulse Withstand Voltage Uimp: 8KV (Frame 63AF: 6KV)
Rated Working Voltage Ue: AC 415V (Frame 63AF: AC 400)
Rated Working Frequency: 50Hz/60Hz
Utilization Category: A
Isolation Function: Applicable for all series
Spreader
Phase Barrier
AC Motor Mechanism
Round Extended Rotary Handle
Square Extended Rotary Handle
MX
MN
Plug-in Connecting Terminal
Plug-in Front Connection
Drawer-out Rear Connection
Plug-in Rear Connection
Fixed Rear Connection
Mechanical Interlock
SD
OF
069
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Complete Functions
Optional Tipping Unit Functions
The tripping unit is the intelligent part of the moulded case circuit breaker.
CDM6s Thermal Magnetic Tripping Unit is divided into 2 types, that is, Fixed Rating and Thermal-
adjustable Tripping Unit.
Fixed Thermal Magnetic Tripping Unit
Thermal-adjustable, Fixed-magnetic Tripping Unit
Be used for overload and short-circuit protection.
Be used for overload and short-circuit protection
Adjustable overload current
Change the relation between the overload current and the rated current by adjusting the
grades of the knobs (0.8-0.9-1.0In, three grades are available to be adjusted). Even so the
current of instantaneous protection movement shall still take the rated current as the base
number
E.g.: The customers need 250AF, 200A current MCCB, and considering the product expansion in
the future, it is required to select the circuit breaker with overload adjustable feature. So which kind
of the product should the customers choose, how much is it for overload tripping release current
(Ir1) and instantaneous tripping release current (Ii)?
Answer: CDM6s, 250AF, M-Type Breaking Capacity, Rated Current 250A, and switch the knob in
the grade of 0.8.
So, Ir1=250A * 0.8=200A, Ii=250 * 10=2500A.
CDM6s All Series of Products Featuring Isolation Function
● The circuit breaker with isolation function shall meet the standard of IEC 60947-2.
● The operating handle hasn’t indicated “OFF” position until the contact has been indeed opened.
● The Isolation Function Protection includes:
○ Mechanical reliability of the contact indication system
○ No leakage current
○ Over-voltage Withstand Capacity between outlet and inlet terminals
070
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Accessory
Name
Accessory
Name
Complete Accessories of CDM6 Series
Indicating Accessories
Auxiliary Contact (OF):
be connected in the auxiliary circuit of switch device and used for the accessories to indicate the
position of the circuit breaker contacts
Alarm Switch (SD):
be used for the accessories under the state of on and off or trip of the indication circuit breaker for
the following 5 reasons:
Overload or short-circuit fault
Residual earth-leakage fault
Artificial Testing Release
Shunt Trip Release
Line Fault and Under-voltage Release Tripping
OF
SD
Rated Thermal Current (A)
Utilization Category
Working Current 50Hz/60Hz
Tripping
Switch-on/off
Switch-on/off
Electrical Parameter of OF & SD
Tripping
Control Accessories
Under-voltage Release (MN)
Tripping threshold between 0.35 and 0.7 times the rated voltage; when it is at 85%-110% of rated
working voltage, Under-voltage Release shall ensure the circuit breaker switch-on; when the
rated working voltage is less than 35%, Undervoltage Release shall prevent switch-on of the
circuit breaker.
Applicable Type of
Circuit Breaker
Power Consumption of Under-voltage Coil (W)
Ue
Undervoltage Release Wiring
071
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Complete Accessories of CDM6 Series
072
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Complete Accessories of CDM6 Series
073
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Alarm Switch Auxiliary Contact Shunt Release Under-voltage
Release
Alarm Switch
Shunt Release
Auxiliary Contact
Undervoltage Release
Installation Location of Accessories
Installation Method for Tripping Release and Accessories Code
Lead Direction
Handle
Installation
at Right Side
Installation
at Left Side
Name of Accessory Product Type
Auxiliary Contact
Shunt Release
Shunt Release
Undervoltage Release
Auxiliary Contact
Undervoltage Release
Shunt-trip Release
Alarm Switch
Undervoltage Release
Alarm Switch
Shunt Release
Auxiliary Contact
Alarm Switch
Auxiliary Contact
Undervoltage Release
Alarm Switch
074
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
:
:
M5*14
M5*14
117
25 25
Φ3.5
(3-pole no size)
117
25
3.5
7
25 25 25
25
117
(3-pole no size)
(3-pole no size)
CDM6s63 Installation Dimension
Chart of Fixed Front Connection Installation Hole
Chart of Fixed Rear Connection Installation Hole
Fixed Rear Connection Wiring Chart of Terminal Connection
Installation Hole
Plug-in Rear Connection Wiring
Chart of Plug-in Rear Connection
Installation Hole
Installation Dimension of Fixed Front Connection
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
L=S/M=T
075
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
7.5
M8*16
129
30 30
Φ4.5
(3-pole no size)
129
30
4.5
12
30 30 30
30
132
(3-pole no size)
(3-pole no size)
CDM6s100 Installation Dimension
Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection
Chart of Fixed Rear Connection Installation Hole Fixed Rear Connection Wiring
Plug-in Rear Connection Wiring
Chart of Terminal Connection
Installation Hole
Chart of Plug-in Rear Connection
Installation Hole
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
L=S/M=T
076
Low-voltage
Distribution
Chart of Terminal Connection
Installation Hole
M8*16
Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection
Fixed Rear Connection Wiring
Plug-in Rear Connection Wiring
Chart of Fixed Rear Connection Installation Hole
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
126
35
4.5
14
35 35 35
35
144
(3-pole no size)
(3-pole no size)
126
35 35
Φ4.5
Chart of Plug-in Rear Connection Installation Hole
CDM6s250 Installation Dimension
(3-pole no size)
L=S/M=T
:
:
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
077
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
078
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
M12*40
CDM6s630 Installation Dimension
Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection
Chart of Fixed Rear Connection
Installation Hole
Fixed Rear Connection Wiring
Plug-in Rear Connection Wiring
Chart of Terminal Connection
Installation Hole
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
200
58 58
Φ5.5
200
58
5.5
40
58 58 58
58
234
(3-pole no size)
(3-pole no size)
Chart of Plug-in Rear Connection
Installation Hole
(3-pole no size)
L=S/M=T
079
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
12
16
M12*40
243
70 70
Φ5.5
243
70
5.5
40
70 70 70
70
243
Chart of Plug-in Rear Connection
Installation Hole
CDM6s800 Installation Dimension
Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection
Fixed Rear Connection Wiring
Plug-in Rear Connection Wiring
Chart of Terminal Connection
Installation Hole
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
Remark: X-X, Y-Y is the center of 3-pole
circuit breaker
Chart of Fixed Rear Connection Installation Hole
(3-pole no size)
(3-pole no size)
(3-pole no size)
L=S/M=T
080
Low-voltage
Distribution
Plug-in Front Connection Installation Dimension (CDM6s100 and CDM6s250)
Drawer-out Rear Connection Base (CDM6s400, CDM6s630 and CDM6s800)
Equipped with
Circuit Breaker
Pole
No.
Equipped with
Circuit Breaker
Equipped with
Circuit Breaker
Pole
No.
Pole
No.
Appearance and Installation Dimension (mm)
Appearance and Installation Dimension (mm)
Appearance Dimension (mm)
Installation
Dimension
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Wire connection
behind board
081
Low-voltage
Distribution
CDM6s 63A-800A Fixed and Plug-in Circuit Breaker Connection Hole-opening Dimension
Safety Distance
Length of Exposed
Conductor +B
Pole
No.
Type of Circuit Breaker
Installation Dimension
AC Motor Mechanism
Remark: no matter whether the products have the accessories, the distance between
the products must meet the requirements of C distance.
Type of Circuit
Breaker
Exposure of Front Cover and
Pull-out Handle
Exposure of Pull-out
Handle Only
Type of Circuit Breaker
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Make
Trip
Break
Manual
Motor Auto
Motor Mechanism
082
Low-voltage
Distribution
80
9
4
80
65
65
80
80
Φ65
Φ4.5
Φ42
Φ36
5
3
32
CDM6s63-800 Frame (3P) Mechanical Interlock Dimension
CDM6s63-800 Frame Extension Rotary Handle Base Dimension
Type of Circuit
Breaker
Type of Circuit
Breaker
Breaking
Capacity Level
Remark: the shortest distance of G connecting rod is 50 mm, and ex-factory standard
configuration is 150mm, please contact the factory, if the special customization is required.
CDM6s63-800 Frame Extension Rotary Handle
Round
Square
≥200 compare to hinge
≥200 compare to hinge
CDM6s63, CDM6s100 and CDM6s250 is 65 or 95 for option, the default value is 65.
CDM6s400, CDM6s630 and CDM6s800 is 95 or 125 for option, the default value is 95.
L,S
M,T
L,S
M,T
L,S
M,T
L/S/M/T
L/S/M/T
L/S/M/T
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
G
083
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
40°C
30°C
20°C
When environmental temperature is over 40°C, small changes have taken place on overload
protection properties. In tripping release time /current curve, the Ir setting value of the circuit breaker
must be corrected as per the following factors.
There is no impact on the performance of the circuit breaker when the height is below 2000m. But
when it is over 2000m, the falling factors as air insulation properties and cooling capability shall
be considered; the correction factors given in the table below are applicable for the conditions of
the height for the installation over 2000m, the breaking capacity of the circuit breaker remains
unchanged.
Altitude (m)
Max.Working Voltage (V)
30°C Thermal Rated Value (A)
Average Isolation Voltage (V)
Dielectric Strength (V)
55
50
45
40
0.94
0.95
0.95
0.94
0.93
0.88
1
1
1
1
1
1
CDM6s 63
CDM6s 100
CDM6s 250
CDM6s 400
CDM6s 630
CDM6s 800
0.88
0.89
0.91
0.87
0.88
0.83
0.80
0.84
0.87
0.81
0.83
0.79
0.72
0.76
0.82
0.73
0.76
0.76
60
Type of Circuit
Breaker
Power-up
Current
Front Connection
Wiring (Standard)
Rear Connection
Wiring Plug-in Wiring
Impact of High Temperature on Tipping Release Performance
Impact of Altitude on Tipping Release Performance
3-Pole (W) Total Power Loss
Type of Circuit
Breaker
Ambient Temperature °C
084
Low-voltage
Distribution
CDM6s100 63A-100A, the black line is used for the distribution. CDM6s250 100A-250A, the black line is used for the distribution.
Instantaneous current range:
10In ± 20%
CDM6s63 10A-63A, the black line is used for the distribution. CDM6s100 16A-50A, the black line is used for the distribution.
Instantaneous current range:
10In ± 20%
Instantaneous current range:
10In ± 20%
Instantaneous current range:
10In ± 20%
Tripping Release Curve
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
085
Low-voltage
Distribution
CDM6s Molded Case Circuit Breaker
Standard: IEC 60947-2
Tripping Release Curve
CDM6s800 700A-800A is used for the power distribution.
.5 .7 1 2 3 4 5 7 10 20 30 50 70100 200 300
5 000
2 000
1 000
500
100
200
50
20
10
5
2
1
.5
.2
.1
.05
.02
.01
.005
.002
.001
I/Ir I/Ir
Instantaneous current range:
10In ± 20%
CDM6s400 200A-400A, the black line is used for the power
distribution.
CDM6s630 400A-630A is used for the power distribution.
CDM6s800 400A-630A is used for the power distribution.
Instantaneous current range:
10In ± 20%
Instantaneous current range:
10In ± 20%
.5 .7 1 2 3 4 5 7 10 20 30 50 70100 200 300
5 000
2 000
1 000
500
100
200
50
20
10
5
2
1
.5
.2
.1
.05
.02
.01
.005
.002
.001
Instantaneous current range:
6In ± 20%
086
Low-voltage
Distribution
Type Pole In A L-type M-type
CDM6L-100 3 40 CDM6L100L403XX*F CDM6L100M403XX*F
50 CDM6L100L503XX*F CDM6L100M503XX*F
63 CDM6L100L633XX*F CDM6L100M633XX*F
80 CDM6L100L803XX*F CDM6L100M803XX*F
100 CDM6L100Ll003XX*F CDM6L100M1003XX*F
4 40 CDM6L100L404XX*F CDM6L100M404XX*F
50 CDM6L100L504XX*F CDM6L100M504XX*F
63 CDM6L100L634XX*F CDM6L100M634XX*F
80 CDM6L100L804XX*F CDM6L100M804XX*F
100 CDM6L100Ll004XX*F CDM6L100M1004XX*F
CDM6L-250 3 100 CDM6L250L1003XX*F CDM6L250M1003XX*F
125 CDM6L250L1253XX*F CDM6L250M1253XX*F
160 CDM6L250L1603XX*F CDM6L250M1603XX*F
180 CDM6L250L1803XX*F CDM6L250M1803XX*F
200 CDM6L250L2003XX*F CDM6L250M2003XX*F
225 CDM6L250L2253XX*F CDM6L250M2253XX*F
250 CDM6L250L2503XX*F CDM6L250M2503XX*F
4 100 CDM6L250L1004XX*F CDM6L250M1004XX*F
125 CDM6L250L1254XX*F CDM6L250M1254XX*F
160 CDM6L250L1604XX*F CDM6L250M1604XX*F
180 CDM6L250L1804XX*F CDM6L250M1804XX*F
200 CDM6L250L2004XX*F CDM6L250M2004XX*F
225 CDM6L250L2254XX*F CDM6L250M2254XX*F
250 CDM6L250L2504XX*F CDM6L250M2504XX*F
CDM6L-400 3 200 CDM6L400L2003XX*F CDM6L400M2003XX*F
225 CDM6L400L2253XX*F CDM6L400M2253XX*F
250 CDM6L400L2503XX*F CDM6L400M2503XX*F
315 CDM6L400L3153XX*F CDM6L400M3153XX*F
350 CDM6L400L3503XX*F CDM6L400M3503XX*F
400 CDM6L400L4003XX*F CDM6L400M4003XX*F
4 200 CDM6L400L2004XX*F CDM6L400M2004XX*F
225 CDM6L400L2254XX*F CDM6L400M2254XX*F
250 CDM6L400L2504XX*F CDM6L400M2504XX*F
315 CDM6L400L3154XX*F CDM6L400M3154XX*F
350 CDM6L400L3504XX*F CDM6L400M3504XX*F
400 CDM6L400L4004XX*F CDM6L400M4004XX*F
CDM6L-630 3 400 CDM6L630L4003XX*F CDM6L630M4003XX*F
500 CDM6L630L5003XX*F CDM6L630M5003XX*F
630 CDM6L630L6303XX*F CDM6L630M6303XX*F
4 400 CDM6L630L4004XX*F CDM6L630M4004XX*F
500 CDM6L630L5004XX*F CDM6L630M5004XX*F
360 CDM6L630L6304XX*F CDM6L630M6304XX*F
name Frame size B.C Rate Current Pole Accessory Voltage of Accessory Residual current Installation method
CDM6L 100 L 100 3P M 1 F R
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
100:100AF
L:L
type
40,50,
63,80,100
3:3P X:No Accessory
X:AC400V;NO Accessory voltage;
Leakage module voltage AC400V
Y:30/100/500mA
(100AF, 250AF)
F:fix-type
in front of the board
250:250AF
M:M
type
100.125.
160.180.200.
225.250
A:4P A Type
N phase is not equipped with overcurrent trip component
and N phase is always connected.
The N phase does not open/close with the other 3 poles.
M:MX
N:AC230V;intenal accessory AC230V;
Leakage module AC230V
T:100/300/500mA
(100AF, 250AF,
400AF, 630AF)
R:fix-type
behind the board
400:400AF
200.225.
250.315.
350.400
B: 4P B Type
N phase is not equipped with overcurrent trip
component, and N phase opens/closes with the other
3 poles. (N phase closes first and then opens)
O:OF D:DC24V
F:300/500/1000mA
(400AF, 630AF)
P:insert-type
behind the board
630:630AF 400.500.630
C: 4P C Type
N phase is equipped with overcurrent trip component, and
N phase always opens/closes with the other 3 poles .
(N phase closes first and then opens)
N:MN
1:Internal accessory AC400V;
Leakage module AC230V
D: 4P D Type
N phase is equipped with overcurrent trip component
and N phase is always connected.
The N phase does not open/close with the other 3 poles
F:OF+OF
2: Internal accessory AC230V;Leakage module
AC400V
S:SD 3:Internal accessory DC24V;Leakage module AC400V
D:OF+S 4:Internal accessory DC24V;Leakage module AC230V
U:Leakage alarm without action module
I:Leakage alarm with action module
A:MX+Leakage alarm without action module
1:MX+Leakage alarm with action module
B:OF+Leakage alarm without action module
2:OF+Leakage alarm with action module
C:MN+Leakage alarm without action module
3:MN+Leakage alarm with action module
E:OF+OF+Leakage alarm without action module
4:OF+OF+Leakage alarm with action module
G:SD+Leakage alarm without action module
5:SD+Leakage alarm with action module
H:OF+SD+Leakage alarm without action module
6:OF+SD+Leakage alarm with action module
Note:* express residual current
Coding System
Order Information
CDM6L Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
087
Low-voltage
Distribution
Thermo-adjustable
Basic Information(IEC60947-2)
Rated Ultimate Short—circuit Breaking
Capacity Icu(kA rms)
Rated Service Short-circuit Breaking
Capacity Ics(kA rms)
Mechanical Endurance
ElectricaI Endurance On-0ff Cycle
100 250 400 630
3P 4P 3P 4P 3P 4P 3P 4P
L M L M L M L M L M L M L M L M
35 50 35 50 35 50 35 50 50 70 50 70 50 70 50 70
22 30 22 30 22 30 22 30 30 40 30 40 30 40 30 40
8500 7000 4000 4000
1500 1000 1000 1000
Tripping Unit
Rated Current(A) In 40/50/63/80/100
100/125/160/180/
200/225/250
200/225/250/315/
350/400
400/500/630
Accessory
Indication Accessories
OF ■ ■ ■ ■
SD ■ ■ ■ ■
Control Accessories
MX(AC400,230V,DC220V) ■ ■ ■ ■
MN(AC400,230V) ■ ■ ■ ■
Extended Rotary Handle(Round and Square) ■ ■ ■ ■
AC Motor Mechanism(AC400,230V) ■ ■ ■ ■
Mounting&Connection
Fixed,Rear Connection ■ ■ ■ ■
Plug-in,Rear Connection ■ ■ ■ ■
Connection
Spreader ■ ■ ■ ■
Protection
Phase Barrier ■ ■ ■ ■
Installation Information See Page 94 See Page 95 See Page 96 See Page 97
"■" shows it has this option
Frame Size AF
Number of Poles
Breaking Capacity Level
Technical Date
CDM6L Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
088
Low-voltage
Distribution
CDM6L Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
● Rated Insulation Voltage Ui,AC 800V
● Rated Impulse Withstand Voltage Uimp,8KV
● Rated Working Voltage Ue,AC 400V
● Rated Operational Frequency,50Hz
● Utilization Category,A
Basic Technical Data
1 Spreader 6 MX 11 SD
2 Phase Barrier 7 MN 12 OF
3 AC Motor Mechanism 8
Leakage Module
(Can't order separately)
4 Round Exended Rotary Handle 9 Plug-in Rear Connection
5 Square Exended Rotary Handle 10 Fixed Rear Connection
Complete Functions and Accessories
089
Low-voltage
Distribution
CDM6L Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Trip unit function
Except the basic features of overload and short circuit protection, the CDM6L residual current
protecting circuit breaker can also provide indirect contact protection for people and prevent fire
accident due to damaged insulation and defective grounding current. The circuit breaker can also add
functions if needed,including electricity leakage alarm.
Versatile functions
The circuit breaker conforms to the latest national standards, and uses reliable 3-phase power supply
technology. If one phase is missing, i.e. there is one phase loss, the circuit breaker can still provide
reliable leakage protection.The product has wide range of voltage input. When the voltage drops to
85V due to power supply failure, the circuit breaker can still provide reliable leakage protection. The
time delay function includes non-delay mode and 3-section delay mode, which can be chosen by the
user according to residual current.
Easy operation
The testing button is easy and convenient to use. The micro-switch has sensitive contact and long
service life. The trip coil has excellent material and performance with remarkable trip indicating
button, which provides a safe and reliable operation environment for clients.
Basic parameter information
The 4-pole products with N phase are divided to four types.
A type: N phase is not equipped with overcurrent trip component and N phase is always connected.
The N phase does not open/close with the other 3 poles
B type: N phase is not equipped with overcurrent trip component, and N phase opens/closes with the
other 3 poles (N phase closes first and then opens)
C type: N phase is equipped with overcurrent trip component, and N phase always opens/closes with
the other 3 poles (N phase closes first and then opens)
D type: N phase is equipped with overcurrent trip component and N phase is always connected.
The N phase does not open/close with the other 3 poles.
Electric motor protection
CDM6L residual current protection circuit breaker with plastic case can be used for electricity
distribution protection, frame current under 400 and electric motor protection.
Isolation function
CDM6L series product has isolation protection function.The operation handle can indicate "OFF"
position only when the contact is really opened.
090
Low-voltage
Distribution
CDM6L Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Complete Accessories of CDM6L Series
Indicating Accessories
● Auxiliary Contact(OF):
Be connected in the auxiliary circuit of switch device and used for the accessories to indicate the
position of the circuit breaker contacts
● Alarm Switch(SD):
Be used for the accessories under the state of on and off or trip of the indication circuit breaker for
the following reasons:
○ Overload or short-circuit fault
○ Residual ea rth-leakage fault
○ Artificial Testing Release
○ Shunt Trip Release
○ Line Fault and Under-voltage Release Tripping
Control Accessories
● Under-voltage Release(MN)
Tripping threshold between 0.35 and 0.7 times the rated voltage;when it is at 85%-110%of
rated working voltage,Under-voltage Release shall ensure re the circuit breaker switch-
on;when the rated working voltage is less than 35,Under voltage Release shall prevent
switch-on of the Circuit breaker
Accessory Name Switch-on/off Tripping
OF
Accessory Name Switch-on/off Tripping
SD
Electrical Parameter of OF&SD
Rated Thermal Current(A)
Utilization Category
Working Current 50Hz AC400V
DC220V
3A
AC15 DC13
0.3A -
- 0.15A
Applicable Type of Circuit Breaker Power Consumption of Under—voltage Coil(W)
AC400V AC230V
CDM6L100 3.9 3.2
CDM6L250 4.3 3.3
CDM6L400 3.6 2.5
CDM6L630 2 1.6
091
Low-voltage
Distribution
CDM6L Earth-Leakage Circuit Breaker
Standard: IEC 60947-2
Complete Accessories of CDM6L Series
● Shunt Release(MX)
When the working voltage is between 70%-110%Us ,the shunt release shall reliably trip the
circuit breaker.
When the rated control supply voltage of the shunt release is DC24V the maximum length of the
copper conductor shall satisfy the following requirements:
When the requirements above cannot be satisfied,it is recommended to adopt the following chart to
design control loop of the shunt release.
● Extended Rotary Handle
○ Function:indication of the three positions of switch—on,switch—off and trip
○ The circuit breaker cannot be switch—on when the switch board door is open
○ The door cannot be opened if the circuit breaker is ON
○ An extension shaft that can be adjusted to the distance between the back of circuit breaker and
door the specific distance refers to the dimensions at the rear and the installation part.
○ The OFF—Position of the circuit breaker can han9 1—3 locks with the diameter of 5 mm
Applicable Type of Circuit Breaker
Power Consumption of Under—voltage Coil(W)
AC400V AC230V DC24V
CDM6L100 96.8 73 91.2
CDM6L250 112 68.6 85.3
CDM6L400 67 62.3 100
CDM6L630 163 153 120
1.5mm² 2.5mm²
100%Us
85%Us
150m
100m
250m
160m
Conductor Area Rated
Control Supply
Voltage(DC24V)
Shunt release
AC50Hz 230V, 400V;
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf
delixicat.pdf

More Related Content

Similar to delixicat.pdf

Similar to delixicat.pdf (20)

HV Elbows, Nexans Euromold Connectors HV - 158LR Connectors, 12kV 250Amp - 70...
HV Elbows, Nexans Euromold Connectors HV - 158LR Connectors, 12kV 250Amp - 70...HV Elbows, Nexans Euromold Connectors HV - 158LR Connectors, 12kV 250Amp - 70...
HV Elbows, Nexans Euromold Connectors HV - 158LR Connectors, 12kV 250Amp - 70...
 
Iskra Low Voltage Switchgear
Iskra Low Voltage SwitchgearIskra Low Voltage Switchgear
Iskra Low Voltage Switchgear
 
Catalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnCatalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vn
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnCatalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vn
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Nexans Euromold 158LR Screened Separable Connectors 200 Series up to 250A 24k...
Nexans Euromold 158LR Screened Separable Connectors 200 Series up to 250A 24k...Nexans Euromold 158LR Screened Separable Connectors 200 Series up to 250A 24k...
Nexans Euromold 158LR Screened Separable Connectors 200 Series up to 250A 24k...
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fuji
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Catalog mcb fuji electric
Catalog mcb fuji electricCatalog mcb fuji electric
Catalog mcb fuji electric
 
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area LightingFloodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting
 
06 - MCCB & ACB - Fuji Electric
06 - MCCB & ACB - Fuji Electric06 - MCCB & ACB - Fuji Electric
06 - MCCB & ACB - Fuji Electric
 
Contactor lc1d schneider
Contactor lc1d schneiderContactor lc1d schneider
Contactor lc1d schneider
 
Contactor LC1D schneider
Contactor LC1D schneiderContactor LC1D schneider
Contactor LC1D schneider
 
Contactor lc1 d schneider
Contactor lc1 d schneiderContactor lc1 d schneider
Contactor lc1 d schneider
 

Recently uploaded

Seizure stage detection of epileptic seizure using convolutional neural networks
Seizure stage detection of epileptic seizure using convolutional neural networksSeizure stage detection of epileptic seizure using convolutional neural networks
Seizure stage detection of epileptic seizure using convolutional neural networks
IJECEIAES
 
electrical installation and maintenance.
electrical installation and maintenance.electrical installation and maintenance.
electrical installation and maintenance.
benjamincojr
 
21P35A0312 Internship eccccccReport.docx
21P35A0312 Internship eccccccReport.docx21P35A0312 Internship eccccccReport.docx
21P35A0312 Internship eccccccReport.docx
rahulmanepalli02
 
Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...
Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...
Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...
drjose256
 

Recently uploaded (20)

What is Coordinate Measuring Machine? CMM Types, Features, Functions
What is Coordinate Measuring Machine? CMM Types, Features, FunctionsWhat is Coordinate Measuring Machine? CMM Types, Features, Functions
What is Coordinate Measuring Machine? CMM Types, Features, Functions
 
Lab Manual Arduino UNO Microcontrollar.docx
Lab Manual Arduino UNO Microcontrollar.docxLab Manual Arduino UNO Microcontrollar.docx
Lab Manual Arduino UNO Microcontrollar.docx
 
Low Altitude Air Defense (LAAD) Gunner’s Handbook
Low Altitude Air Defense (LAAD) Gunner’s HandbookLow Altitude Air Defense (LAAD) Gunner’s Handbook
Low Altitude Air Defense (LAAD) Gunner’s Handbook
 
21scheme vtu syllabus of visveraya technological university
21scheme vtu syllabus of visveraya technological university21scheme vtu syllabus of visveraya technological university
21scheme vtu syllabus of visveraya technological university
 
The Entity-Relationship Model(ER Diagram).pptx
The Entity-Relationship Model(ER Diagram).pptxThe Entity-Relationship Model(ER Diagram).pptx
The Entity-Relationship Model(ER Diagram).pptx
 
"United Nations Park" Site Visit Report.
"United Nations Park" Site  Visit Report."United Nations Park" Site  Visit Report.
"United Nations Park" Site Visit Report.
 
handbook on reinforce concrete and detailing
handbook on reinforce concrete and detailinghandbook on reinforce concrete and detailing
handbook on reinforce concrete and detailing
 
Autodesk Construction Cloud (Autodesk Build).pptx
Autodesk Construction Cloud (Autodesk Build).pptxAutodesk Construction Cloud (Autodesk Build).pptx
Autodesk Construction Cloud (Autodesk Build).pptx
 
Raashid final report on Embedded Systems
Raashid final report on Embedded SystemsRaashid final report on Embedded Systems
Raashid final report on Embedded Systems
 
Geometric constructions Engineering Drawing.pdf
Geometric constructions Engineering Drawing.pdfGeometric constructions Engineering Drawing.pdf
Geometric constructions Engineering Drawing.pdf
 
Seizure stage detection of epileptic seizure using convolutional neural networks
Seizure stage detection of epileptic seizure using convolutional neural networksSeizure stage detection of epileptic seizure using convolutional neural networks
Seizure stage detection of epileptic seizure using convolutional neural networks
 
electrical installation and maintenance.
electrical installation and maintenance.electrical installation and maintenance.
electrical installation and maintenance.
 
21P35A0312 Internship eccccccReport.docx
21P35A0312 Internship eccccccReport.docx21P35A0312 Internship eccccccReport.docx
21P35A0312 Internship eccccccReport.docx
 
Involute of a circle,Square, pentagon,HexagonInvolute_Engineering Drawing.pdf
Involute of a circle,Square, pentagon,HexagonInvolute_Engineering Drawing.pdfInvolute of a circle,Square, pentagon,HexagonInvolute_Engineering Drawing.pdf
Involute of a circle,Square, pentagon,HexagonInvolute_Engineering Drawing.pdf
 
Piping and instrumentation diagram p.pdf
Piping and instrumentation diagram p.pdfPiping and instrumentation diagram p.pdf
Piping and instrumentation diagram p.pdf
 
Augmented Reality (AR) with Augin Software.pptx
Augmented Reality (AR) with Augin Software.pptxAugmented Reality (AR) with Augin Software.pptx
Augmented Reality (AR) with Augin Software.pptx
 
Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...
Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...
Tembisa Central Terminating Pills +27838792658 PHOMOLONG Top Abortion Pills F...
 
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
 
Artificial Intelligence in due diligence
Artificial Intelligence in due diligenceArtificial Intelligence in due diligence
Artificial Intelligence in due diligence
 
NO1 Best Powerful Vashikaran Specialist Baba Vashikaran Specialist For Love V...
NO1 Best Powerful Vashikaran Specialist Baba Vashikaran Specialist For Love V...NO1 Best Powerful Vashikaran Specialist Baba Vashikaran Specialist For Love V...
NO1 Best Powerful Vashikaran Specialist Baba Vashikaran Specialist For Love V...
 

delixicat.pdf

  • 1.
  • 2.
  • 3.
  • 4. Delixi Electric: Who are we A global company at your service A reliable company serving you with reliable product Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM€,employing more than 15000 people. Delixi created an international Joint Venture in November 2007,named Delixi Electric Ltd., in order to serve you worldwide,with core LV products having the right quality at the right price. Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric employs 5200 people world wide. Dedicated R&D center International quality control of suppliers International quality control of plants Fully automatized distribution center Network of recognized 600 distributors world wide
  • 5. Reliable Quality For more details, please contact your local Delixi Electric Company.
  • 6. I 046-050 051-055 056-057 058-062 002-029 030-045 Contents Final Distribution Miniature Circuit Breaker & Switch Disconnectors Residual Current Devices Accessories for MCB&RCBO Control Devices Surge Protective Device Distribution Box CDB6 18mm Miniature Circuit Breaker 002 CDB6s 18mm Miniature Circuit Breaker 007 CDB9 18mm Miniature Circuit Breaker 011 CDB2 27mm Miniature Circuit Breaker 016 CDB6p Phase-neutral Circuit Breaker 019 CDB3 Phase-neutral Circuit Breaker 021 CDB6IS Switch Disconnector 023 CDB5 Switch Disconnector 025 CDG9 Switch Disconnector 027 CDB6LE Residual Current Operated Circuit Breaker 030 CDB6v Residual Current Protection Module 033 CDB2LE Residual Current Operated Circuit Breaker 036 CDB6pLE Residual Current Operated Circuit Breaker 039 CDB3LE Residual Current Operated Circuit Breaker 041 CDL6SP Residual Current Operated Circuit Breaker 043 CDB6VR Electromagnetic Type Residual Current Switch 044 SD,OF,MX+OF 046 Busbar 050 CDCH8P Modular Contactor 051 CDRT8 Time Relay 054 CDPZ50 Series Consumer Box 058 JXF Metal Enclosure 060 CDY1 Surge Protective Device 056
  • 7. II 120-193 063-119 194-245 246-247 248-257 Low-voltage Distribution Motor Control & Protection Molded Case Circuit Breaker Air Circuit Breaker Contactor&Thermal Overload Relay Definite Purpose Contactor Relay CDM6s Molded Case Circuit Breaker 063 CDM6L Earth-Leakage Circuit Breaker 086 CDM1 Molded Case Circuit Breaker 103 CDM1LE Earth-Leakage Circuit Breaker 112 CDC6 AC Contactor 194 CDR6 Thermal Overload Relay 210 CDC17-K Mini AC Contactor 220 CDR17-18 Thermal Overload Relay 223 CJX2 AC AC Contactor 227 JRS1D Thermal Overload Relay 233 JRS2 Thermal Overload Relay 238 CDZ6 Contactor Relay 248 CDZ8P Miniature Relay 251 JSZ3 Electronic Time Relay 253 XJ9 Phase Failure and Sequence Protection Relay 256 CDTL17 Impluse Relay 257 CDC9 Capacitor Switching Contactor 246 CDW9 Air Circuit Breaker 120 CDW6 Air Circuit Breaker 169
  • 8. III 265-266 267-270 271-283 284-287 288-294 Power Energy Management Motor Protector Magnetic Starter Current Transformer Meter Digital Time Switch Voltage Stabilizer 258-264 CDP6 Motor Protector 258 CDS2 Magnetic Starter 265 LMK Series Current Transformer 267 DDS607 Single-phase Electronic Watt-hour Meter 271 DTS607 Three-phase Four-Wire Electronic Watt-hour Meter 273 DSS607 Three-phase Three-Wire Electronic Watt-hour Meter 276 72 Series Panel Meter 279 96 Series Panel Meter 281 KG316T Digital Time Switch 284 KG316TD Digital Time Switch 285 KG816 Digital Time Switch 286 TND Single-phase Full Automatic AC Voltage Stabilizer 288 SJW Three-phase Full Automatic AC Voltage Stabilizer 290 SBW Three-phase Compensation AC Voltage Stabilizer 292
  • 9. IV 321-327 328-333 334-339 Industrial Control Components Control Signal Fuse Industrial Plug&Socket Accessories 295-320 LD11 Indicator Light 295 LAY5 Pushbutton Switches 299 LAY7 Pushbutton Switches 309 LAY8 Pushbutton Switches 315 CDPM Moving Industrial Plugs 328 CDP Fixed Industrial Plugs 329 CDSM Moving Industrial Sockets 330 CDSF Fixed Industrial Sockets 331 CDPS Multi-function Plugs and Sockets 332 CCF Cable Connector 334 TB Copper Terminal Blocks 335 DIN Din-rail 339 RT16 Fuse 321 RT18 Fuse 324
  • 10. 001 Final Distribution 046 S 002 007 011 016 027 025 023 021 019 * 17 Miniature Circuit Breaker & Switch Disconnectors Product Overview 18mm MCB 18mm 1P+N MCB Accessories Switch Disconnectors 27mm MCB CDB6 CDB6p CDB6IS CDB3 CDB5 CDG9 CDB6s In: 1-63A Breaking Capacity: 3/4.5/6kA In: 6-32A Breaking Capacity: 4.5kA In: 20-125A In: 6-32A Breaking Capacity: 3kA MX+OF SD OF In: 20-100A In: 32-125A In: 1-63A Breaking Capacity: 4.5/6kA CDB2 In: 63-125A Breaking Capacity: 10kA CDB9 In: 1-63A Breaking Capacity: 6/10kA
  • 11. 002 Final Distribution Function 1 3 6 10 16 20 25 32 40 50 63 2 2 2 2 2 2 2 2 2 2 2 1 3 6 10 16 20 25 32 40 50 63 4 4 4 4 4 4 4 4 4 4 4 CDB6a1D1 CDB6a1D3 CDB6a1D6 CDB6a1D10 CDB6a1D16 CDB6a1D20 CDB6a1D25 CDB6a1D32 CDB6a1D40 CDB6a1D50 CDB6a1D63 CDB6a2D1 CDB6a2D3 CDB6a2D6 CDB6a2D10 CDB6a2D16 CDB6a2D20 CDB6a2D25 CDB6a2D32 CDB6a2D40 CDB6a2D50 CDB6a2D63 CDB6a1B1 CDB6a1B3 CDB6a1B6 CDB6a1B10 CDB6a1B16 CDB6a1B20 CDB6a1B25 CDB6a1B32 CDB6a1B40 CDB6a1B50 CDB6a1B63 CDB6a2B1 CDB6a2B3 CDB6a2B6 CDB6a2B10 CDB6a2B16 CDB6a2B20 CDB6a2B25 CDB6a2B32 CDB6a2B40 CDB6a2B50 CDB6a2B63 CDB6a1C1 CDB6a1C3 CDB6a1C6 CDB6a1C10 CDB6a1C16 CDB6a1C20 CDB6a1C25 CDB6a1C32 CDB6a1C40 CDB6a1C50 CDB6a1C63 CDB6a2C1 CDB6a2C3 CDB6a2C6 CDB6a2C10 CDB6a2C16 CDB6a2C20 CDB6a2C25 CDB6a2C32 CDB6a2C40 CDB6a2C50 CDB6a2C63 3 CDB6 a: 3kA L: 4.5kA N: 6kA 1: 1P 2: 2P 3: 3P 4: 4P B: B Curve C: C Curve D: D Curve 1: 1A 3: 3A … 63: 63A 1 3 6 10 16 20 25 32 40 50 63 2 2 2 2 2 2 2 2 2 2 2 CDB6N1B1 CDB6N1B3 CDB6N1B6 CDB6N1B10 CDB6N1B16 CDB6N1B20 CDB6N1B25 CDB6N1B32 CDB6N1B40 - - CDB6N1C1 CDB6N1C3 CDB6N1C6 CDB6N1C10 CDB6N1C16 CDB6N1C20 CDB6N1C25 CDB6N1C32 CDB6N1C40 - - - - - - - - - - - - - CDB6L1D1 CDB6L1D3 CDB6L1D6 CDB6L1D10 CDB6L1D16 CDB6L1D20 CDB6L1D25 CDB6L1D32 CDB6L1D40 CDB6L1D50 CDB6L1D63 CDB6L1C1 CDB6L1C3 CDB6L1C6 CDB6L1C10 CDB6L1C16 CDB6L1C20 CDB6L1C25 CDB6L1C32 CDB6L1C40 CDB6L1C50 CDB6L1C63 CDB6L1B1 CDB6L1B3 CDB6L1B6 CDB6L1B10 CDB6L1B16 CDB6L1B20 CDB6L1B25 CDB6L1B32 CDB6L1B40 CDB6L1B50 CDB6L1B63 1 3 6 10 16 20 25 32 40 50 63 2 2 2 2 2 2 2 2 2 2 2 4.5 6 2P 3 Type Name Breaking Capacity Rating (A) Width D curve Reference Pole Type Rated current C curve B curve Breaking Capacity (kA) CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000/4500/6000A Order Information Note: Width refers to multiple of 9 mm. CDB6 miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation 1P
  • 12. 003 Final Distribution Order Information CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000/4500/6000A CDB6L2D1 CDB6L2D3 CDB6L2D6 CDB6L2D10 CDB6L2D16 CDB6L2D20 CDB6L2D25 CDB6L2D32 CDB6L2D40 CDB6L2D50 CDB6L2D63 CDB6L2C1 CDB6L2C3 CDB6L2C6 CDB6L2C10 CDB6L2C16 CDB6L2C20 CDB6L2C25 CDB6L2C32 CDB6L2C40 CDB6L2C50 CDB6L2C63 CDB6L2B1 CDB6L2B3 CDB6L2B6 CDB6L2B10 CDB6L2B16 CDB6L2B20 CDB6L2B25 CDB6L2B32 CDB6L2B40 CDB6L2B50 CDB6L2B63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 4 4 4 4 4 4 4 4 4 4 4 CDB6N2B1 CDB6N2B3 CDB6N2B6 CDB6N2B10 CDB6N2B16 CDB6N2B20 CDB6N2B25 CDB6N2B32 CDB6N2B40 - - CDB6N2C1 CDB6N2C3 CDB6N2C6 CDB6N2C10 CDB6N2C16 CDB6N2C20 CDB6N2C25 CDB6N2C32 CDB6N2C40 - - - - - - - - - - - - - 4 4 4 4 4 4 4 4 4 4 4 4.5 6 1 3 6 10 16 20 25 32 40 50 63 6 6 6 6 6 6 6 6 6 6 6 CDB6a3D1 CDB6a3D3 CDB6a3D6 CDB6a3D10 CDB6a3D16 CDB6a3D20 CDB6a3D25 CDB6a3D32 CDB6a3D40 CDB6a3D50 CDB6a3D63 CDB6a3B1 CDB6a3B3 CDB6a3B6 CDB6a3B10 CDB6a3B16 CDB6a3B20 CDB6a3B25 CDB6a3B32 CDB6a3B40 CDB6a3B50 CDB6a3B63 CDB6a3C1 CDB6a3C3 CDB6a3C6 CDB6a3C10 CDB6a3C16 CDB6a3C20 CDB6a3C25 CDB6a3C32 CDB6a3C40 CDB6a3C50 CDB6a3C63 3 CDB6L3D1 CDB6L3D3 CDB6L3D6 CDB6L3D10 CDB6L3D16 CDB6L3D20 CDB6L3D25 CDB6L3D32 CDB6L3D40 CDB6L3D50 CDB6L3D63 CDB6L3C1 CDB6L3C3 CDB6L3C6 CDB6L3C10 CDB6L3C16 CDB6L3C20 CDB6L3C25 CDB6L3C32 CDB6L3C40 CDB6L3C50 CDB6L3C63 CDB6L3B1 CDB6L3B3 CDB6L3B6 CDB6L3B10 CDB6L3B16 CDB6L3B20 CDB6L3B25 CDB6L3B32 CDB6L3B40 CDB6L3B50 CDB6L3B63 1 3 6 10 16 20 25 32 40 50 63 6 6 6 6 6 6 6 6 6 6 6 4.5 Type Rating (A) Width D curve Reference C curve Breaking Capacity (kA) B curve 3P Note: Width refers to multiple of 9 mm.
  • 13. 004 Final Distribution Order Information CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000/4500/6000A Note: Width refers to multiple of 9 mm. CDB6a4D1 CDB6a4D3 CDB6a4D6 CDB6a4D10 CDB6a4D16 CDB6a4D20 CDB6a4D25 CDB6a4D32 CDB6a4D40 CDB6a4D50 CDB6a4D63 - - - - - - - - - - - - - - - - - - - - - - CDB6a4B1 CDB6a4B3 CDB6a4B6 CDB6a4B10 CDB6a4B16 CDB6a4B20 CDB6a4B25 CDB6a4B32 CDB6a4B40 CDB6a4B50 CDB6a4B63 CDB6N3B1 CDB6N3B3 CDB6N3B6 CDB6N3B10 CDB6N3B16 CDB6N3B20 CDB6N3B25 CDB6N3B32 CDB6N3B40 - - CDB6a4C1 CDB6a4C3 CDB6a4C6 CDB6a4C10 CDB6a4C16 CDB6a4C20 CDB6a4C25 CDB6a4C32 CDB6a4C40 CDB6a4C50 CDB6a4C63 CDB6N3C1 CDB6N3C3 CDB6N3C6 CDB6N3C10 CDB6N3C16 CDB6N3C20 CDB6N3C25 CDB6N3C32 CDB6N3C40 - - 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 8 8 8 8 8 8 8 8 8 8 8 6 6 6 6 6 6 6 6 6 6 6 3 6 Type Rating (A) Width D curve Reference C curve Breaking Capacity (kA) B curve 4P CDB6L4D1 CDB6L4D3 CDB6L4D6 CDB6L4D10 CDB6L4D16 CDB6L4D20 CDB6L4D25 CDB6L4D32 CDB6L4D40 CDB6L4D50 CDB6L4D63 CDB6L4C1 CDB6L4C3 CDB6L4C6 CDB6L4C10 CDB6L4C16 CDB6L4C20 CDB6L4C25 CDB6L4C32 CDB6L4C40 CDB6L4C50 CDB6L4C63 CDB6N4C1 CDB6N4C3 CDB6N4C6 CDB6N4C10 CDB6N4C16 CDB6N4C20 CDB6N4C25 CDB6N4C32 CDB6N4C40 - - CDB6L4B1 CDB6L4B3 CDB6L4B6 CDB6L4B10 CDB6L4B16 CDB6L4B20 CDB6L4B25 CDB6L4B32 CDB6L4B40 CDB6L4B50 CDB6L4B63 CDB6N4B1 CDB6N4B3 CDB6N4B6 CDB6N4B10 CDB6N4B16 CDB6N4B20 CDB6N4B25 CDB6N4B32 CDB6N4B40 - - 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4.5 6
  • 14. 005 Final Distribution Technical Data IEC60898-1 CB, CE, RoHS 1-4P 1,3,6,10,16,20,25,32,40,50,63 A 230/400V AC 500V 3 4.5 6 4.5 B,C,D B,C,D B,C B,C 230/400 400 230/400 400 230/400 400 230/400 400 1-63 1-63 1-40 50,63 Accessories Contact Accessory Fault-indicating Accessories Shunt -trip release OF SD MX+OF 35mm Din-rail Rate Current(A) Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature B Curve:the magnetic release operates between 3 and 5 In C Curve:the magnetic release operates between 5 and 10 In D Curve:the magnetic release operates between 10 and 14 In Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui 4000 times 10000 times 2 treatment 2 -5°C ~ +40°C Screw Rated Torque (Nm) Limiting Torque (Nm) 1-63 M5 Up to 25mm2 cables 2.5 4.5 Mounting Installation Connection Mechanical Features Electrical Features MCB CDB6 18mm Circuit Breaker Breaking Capacity Icn Tripping Curve(see following tripping curve pictures) Rate current(A) Breaking capacity lcn(kA) Type 1P 2P, 3P, 4P 1P 2P, 3P, 4P 1P 2P, 3P, 4P 1P 2P, 3P, 4P Poles Voltage (V) CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000/4500/6000A
  • 15. 006 Final Distribution SD OF CDB6 MX+OF Tripping Curve Overall Dimensions Accessories CDB6 Miniature Circuit Breaker The Sketch Map of Installation with Breakers CDB6 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 3000/4500/6000A
  • 16. 007 Final Distribution Function CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500/6000A CDB6s miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation 2P 4.5/6 CDB6sN2B1 CDB6sN2B2 CDB6sN2B3 CDB6sN2B4 CDB6sN2B5 CDB6sN2B6 CDB6sN2B8 CDB6sN2B10 CDB6sN2B13 CDB6sN2B16 CDB6sN2B20 CDB6sN2B25 CDB6sN2B32 CDB6sN2B40 CDB6sL2B50 CDB6sL2B63 CDB6sN2C1 CDB6sN2C2 CDB6sN2C3 CDB6sN2C4 CDB6sN2C5 CDB6sN2C6 CDB6sN2C8 CDB6sN2C10 CDB6sN2C13 CDB6sN2C16 CDB6sN2C20 CDB6sN2C25 CDB6sN2C32 CDB6sN2C40 CDB6sL2C50 CDB6sL2C63 CDB6sL2D1 CDB6sL2D2 CDB6sL2D3 CDB6sL2D4 CDB6sL2D5 CDB6sL2D6 CDB6sL2D8 CDB6sL2D10 CDB6sL2D13 CDB6sL2D16 CDB6sL2D20 CDB6sL2D25 CDB6sL2D32 CDB6sL2D40 CDB6sL2D50 CDB6sL2D63 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1P Note: Width refers to multiple of 9 mm. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4.5/6 CDB6sN1B1 CDB6sN1B2 CDB6sN1B3 CDB6sN1B4 CDB6sN1B5 CDB6sN1B6 CDB6sN1B8 CDB6sN1B10 CDB6sN1B13 CDB6sN1B16 CDB6sN1B20 CDB6sN1B25 CDB6sN1B32 CDB6sN1B40 CDB6sL1B50 CDB6sL1B63 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 CDB6sN1C1 CDB6sN1C2 CDB6sN1C3 CDB6sN1C4 CDB6sN1C5 CDB6sN1C6 CDB6sN1C8 CDB6sN1C10 CDB6sN1C13 CDB6sN1C16 CDB6sN1C20 CDB6sN1C25 CDB6sN1C32 CDB6sN1C40 CDB6sL1C50 CDB6sL1C63 CDB6sL1D1 CDB6sL1D2 CDB6sL1D3 CDB6sL1D4 CDB6sL1D5 CDB6sL1D6 CDB6sL1D8 CDB6sL1D10 CDB6sL1D13 CDB6sL1D16 CDB6sL1D20 CDB6sL1D25 CDB6sL1D32 CDB6sL1D40 CDB6sL1D50 CDB6sL1D63 Type Breaking Capacity (kA) Rating (A) Width D curve C curve Reference B curve Order Information CDB6s L: 4.5kA N: 6kA 1: 1P 2: 2P 3: 3P 4: 4P B: B Curve C: C Curve D: D Curve 1: 1A 2: 2A … 63: 63A Name Breaking Capacity Pole Type Rated current
  • 17. 008 Final Distribution CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500/6000A Order Information 4.5/6 Type Breaking Capacity (kA) Rating (A) Width D curve C curve Reference B curve CDB6sN3B1 CDB6sN3B2 CDB6sN3B3 CDB6sN3B4 CDB6sN3B5 CDB6sN3B6 CDB6sN3B8 CDB6sN3B10 CDB6sN3B13 CDB6sN3B16 CDB6sN3B20 CDB6sN3B25 CDB6sN3B32 CDB6sN3B40 CDB6sL3B50 CDB6sL3B63 CDB6sN3C1 CDB6sN3C2 CDB6sN3C3 CDB6sN3C4 CDB6sN3C5 CDB6sN3C6 CDB6sN3C8 CDB6sN3C10 CDB6sN3C13 CDB6sN3C16 CDB6sN3C20 CDB6sN3C25 CDB6sN3C32 CDB6sN3C40 CDB6sL3C50 CDB6sL3C63 CDB6sL3D1 CDB6sL3D2 CDB6sL3D3 CDB6sL3D4 CDB6sL3D5 CDB6sL3D6 CDB6sL3D8 CDB6sL3D10 CDB6sL3D13 CDB6sL3D16 CDB6sL3D20 CDB6sL3D25 CDB6sL3D32 CDB6sL3D40 CDB6sL3D50 CDB6sL3D63 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 3P 4P 4.5/6 CDB6sN4B1 CDB6sN4B2 CDB6sN4B3 CDB6sN4B4 CDB6sN4B5 CDB6sN4B6 CDB6sN4B8 CDB6sN4B10 CDB6sN4B13 CDB6sN4B16 CDB6sN4B20 CDB6sN4B25 CDB6sN4B32 CDB6sN4B40 CDB6sL4B50 CDB6sL4B63 CDB6sN4C1 CDB6sN4C2 CDB6sN4C3 CDB6sN4C4 CDB6sN4C5 CDB6sN4C6 CDB6sN4C8 CDB6sN4C10 CDB6sN4C13 CDB6sN4C16 CDB6sN4C20 CDB6sN4C25 CDB6sN4C32 CDB6sN4C40 CDB6sL4C50 CDB6sL4C63 CDB6sL4D1 CDB6sL4D2 CDB6sL4D3 CDB6sL4D4 CDB6sL4D5 CDB6sL4D6 CDB6sL4D8 CDB6sL4D10 CDB6sL4D13 CDB6sL4D16 CDB6sL4D20 CDB6sL4D25 CDB6sL4D32 CDB6sL4D40 CDB6sL4D50 CDB6sL4D63 1 2 3 4 5 6 8 10 13 16 20 25 32 40 50 63 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Note: Width refers to multiple of 9 mm.
  • 18. 009 Final Distribution CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500/6000A Technical Data 1P 230/400 2P, 3P, 4P 400 6 B,C 1-40 4.5 B,C 50,63 1P 230/400 2P, 3P, 4P 400 4.5 D 1-63 1P 230/400 2P, 3P, 4P 400 Breaking capacity lcn(kA) Accessories Contact Accessory Fault-indicating Accessory Shunt-trip Release OF SD MX+OF 35mm Din-rail Rate Current(A) Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperture B curve;the magnetic release operates between 3 and 5 In C curve;the magnetic release operates between 5 and 10 In D curve;the magnetic release operates between 10 and 14 In Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui IEC 60898-1 KEMA CB CE 1-4P 1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A 230/400V AC 500V 4000 times 10000 times 2 treatment 2 -5°C ~ +40°C Screw Rated Torque (Nm) Limiting Torque (Nm) 1-63 M5 Up to 25mm2 cables 2.5 4.5 Mounting Installation Connection Mechanical Features Electrical Features MCB CDB6s 18mm Circuit Breaker Breaking Capacity Icn Tripping Curve ( see following tripping curve pictures) Rate current(A) Type Poles Voltage (V)
  • 19. 010 Final Distribution CDB6s 18mm Miniature Circuit Breaker Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500/6000A Tripping Curves Overall Dimensions Accessories SD OF MX+OF CDB6s :67.21–0.43 88 max 4P 3P 2P 1P Unit: mm
  • 20. 011 Final Distribution Function CDB9 miniature circuit breakers combine the following functions: ● Protection of circuits against overload currents ● Protection of circuits against short-circuit currents ● Control ● Isolation Type Breaking Capacity(kA) Rating(A) Width Reference B Curve C Curve D Curve 1P 6 1 2 CDB9N631B1 CDB9N631C1 CDB9N631D1 2 2 CDB9N631B2 CDB9N631C2 CDB9N631D2 4 2 CDB9N631B4 CDB9N631C4 CDB9N631D4 6 2 CDB9N631B6 CDB9N631C6 CDB9N631D6 10 2 CDB9N631B10 CDB9N631C10 CDB9N631D10 16 2 CDB9N631B16 CDB9N631C16 CDB9N631D16 20 2 CDB9N631B20 CDB9N631C20 CDB9N631D20 25 2 CDB9N631B25 CDB9N631C25 CDB9N631D25 32 2 CDB9N631B32 CDB9N631C32 CDB9N631D32 40 2 CDB9N631B40 CDB9N631C40 CDB9N631D40 50 2 CDB9N631B50 CDB9N631C50 CDB9N631D50 63 2 CDB9N631B63 CDB9N631C63 CDB9N631D63 10 1 2 CDB9H631B1 CDB9H631C1 CDB9H631D1 2 2 CDB9H631B2 CDB9H631C2 CDB9H631D2 4 2 CDB9H631B4 CDB9H631C4 CDB9H631D4 6 2 CDB9H631B6 CDB9H631C6 CDB9H631D6 10 2 CDB9H631B10 CDB9H631C10 CDB9H631D10 16 2 CDB9H631B16 CDB9H631C16 CDB9H631D16 20 2 CDB9H631B20 CDB9H631C20 CDB9H631D20 25 2 CDB9H631B25 CDB9H631C25 CDB9H631D25 32 2 CDB9H631B32 CDB9H631C32 CDB9H631D32 40 2 CDB9H631B40 CDB9H631C40 CDB9H631D40 50 2 CDB9H631B50 CDB9H631C50 CDB9H631D50 63 2 CDB9H631B63 CDB9H631C63 CDB9H631D63 Note:Width refers to multiple of 9 mm. B curve products need to customize Name Breaking Capacity(kA) Frame Size Pole Type Rated current CDB9 N: 6kA 63:63AF 1:1P B:B Curve 1:1A H: 10kA 2:2P C:C Curve 2:2A 3:3P D:D Curve ··· 4:4P 63:63A Order Information CDB9 18mm Miniature Circuit Breaker Standard:IEC 60898-1 Trip Curve:B,C and D curves Breaking Capacity: 6000/10000A
  • 21. 012 Final Distribution Note:Width refers to multiple of 9 mm. B curve products need to customize Type Breaking Capacity(kA) Rating(A) Width Reference B Curve C Curve D Curve 2P 6 1 4 CDB9N632B1 CDB9N632C1 CDB9N632D1 2 4 CDB9N632B2 CDB9N632C2 CDB9N632D2 4 4 CDB9N632B4 CDB9N632C4 CDB9N632D4 6 4 CDB9N632B6 CDB9N632C6 CDB9N632D6 10 4 CDB9N632B10 CDB9N632C10 CDB9N632D10 16 4 CDB9N632B16 CDB9N632C16 CDB9N632D16 20 4 CDB9N632B20 CDB9N632C20 CDB9N632D20 25 4 CDB9N632B25 CDB9N632C25 CDB9N632D25 32 4 CDB9N632B32 CDB9N632C32 CDB9N632D32 40 4 CDB9N632B40 CDB9N632C40 CDB9N632D40 50 4 CDB9N632B50 CDB9N632C50 CDB9N632D50 63 4 CDB9N632B63 CDB9N632C63 CDB9N632D63 10 1 4 CDB9H632B1 CDB9H632C1 CDB9H632D1 2 4 CDB9H632B2 CDB9H632C2 CDB9H632D2 4 4 CDB9H632B4 CDB9H632C4 CDB9H632D4 6 4 CDB9H632B6 CDB9H632C6 CDB9H632D6 10 4 CDB9H632B10 CDB9H632C10 CDB9H632D10 16 4 CDB9H632B16 CDB9H632C16 CDB9H632D16 20 4 CDB9H632B20 CDB9H632C20 CDB9H632D20 25 4 CDB9H632B25 CDB9H632C25 CDB9H632D25 32 4 CDB9H632B32 CDB9H632C32 CDB9H632D32 40 4 CDB9H632B40 CDB9H632C40 CDB9H632D40 50 4 CDB9H632B50 CDB9H632C50 CDB9H632D50 63 4 CDB9H632B63 CDB9H632C63 CDB9H632D63 6 1 6 CDB9N633B1 CDB9N633C1 CDB9N633D1 2 6 CDB9N633B2 CDB9N633C2 CDB9N633D2 4 6 CDB9N633B4 CDB9N633C4 CDB9N633D4 6 6 CDB9N633B6 CDB9N633C6 CDB9N633D6 10 6 CDB9N633B10 CDB9N633C10 CDB9N633D10 16 6 CDB9N633B16 CDB9N633C16 CDB9N633D16 20 6 CDB9N633B20 CDB9N633C20 CDB9N633D20 25 6 CDB9N633B25 CDB9N633C25 CDB9N633D25 32 6 CDB9N633B32 CDB9N633C32 CDB9N633D32 40 6 CDB9N633B40 CDB9N633C40 CDB9N633D40 50 6 CDB9N633B50 CDB9N633C50 CDB9N633D50 63 6 CDB9N633B63 CDB9N633C63 CDB9N633D63 3P Order Information CDB9 18mm Miniature Circuit Breaker Standard:IEC 60898-1 Trip Curve:B,C and D curves Breaking Capacity: 6000/10000A
  • 22. 013 Final Distribution Note:Width refers to multiple of 9 mm. B curve products need to customize Type Breaking Capacity(kA) Rating(A) Width Reference B Curve C Curve D Curve 10 1 6 CDB9H633B1 CDB9H633C1 CDB9H633D1 2 6 CDB9H633B2 CDB9H633C2 CDB9H633D2 4 6 CDB9H633B4 CDB9H633C4 CDB9H633D4 6 6 CDB9H633B6 CDB9H633C6 CDB9H633D6 10 6 CDB9H633B10 CDB9H633C10 CDB9H633D10 16 6 CDB9H633B16 CDB9H633C16 CDB9H633D16 20 6 CDB9H633B20 CDB9H633C20 CDB9H633D20 25 6 CDB9H633B25 CDB9H633C25 CDB9H633D25 32 6 CDB9H633B32 CDB9H633C32 CDB9H633D32 40 6 CDB9H633B40 CDB9H633C40 CDB9H633D40 50 6 CDB9H633B50 CDB9H633C50 CDB9H633D50 63 6 CDB9H633B63 CDB9H633C63 CDB9H633D63 6 1 8 CDB9N634B1 CDB9N634C1 CDB9N634D1 2 8 CDB9N634B2 CDB9N634C2 CDB9N634D2 4 8 CDB9N634B4 CDB9N634C4 CDB9N634D4 6 8 CDB9N634B6 CDB9N634C6 CDB9N634D6 10 8 CDB9N634B10 CDB9N634C10 CDB9N634D10 16 8 CDB9N634B16 CDB9N634C16 CDB9N634D16 20 8 CDB9N634B20 CDB9N634C20 CDB9N634D20 25 8 CDB9N634B25 CDB9N634C25 CDB9N634D25 32 8 CDB9N634B32 CDB9N634C32 CDB9N634D32 40 8 CDB9N634B40 CDB9N634C40 CDB9N634D40 50 8 CDB9N634B50 CDB9N634C50 CDB9N634D50 63 8 CDB9N634B63 CDB9N634C63 CDB9N634D63 10 1 8 CDB9H634B1 CDB9H634C1 CDB9H634D1 2 8 CDB9H634B2 CDB9H634C2 CDB9H634D2 4 8 CDB9H634B4 CDB9H634C4 CDB9H634D4 6 8 CDB9H634B6 CDB9H634C6 CDB9H634D6 10 8 CDB9H634B10 CDB9H634C10 CDB9H634D10 16 8 CDB9H634B16 CDB9H634C16 CDB9H634D16 20 8 CDB9H634B20 CDB9H634C20 CDB9H634D20 25 8 CDB9H634B25 CDB9H634C25 CDB9H634D25 32 8 CDB9H634B32 CDB9H634C32 CDB9H634D32 40 8 CDB9H634B40 CDB9H634C40 CDB9H634D40 50 8 CDB9H634B50 CDB9H634C50 CDB9H634D50 63 8 CDB9H634B63 CDB9H634C63 CDB9H634D63 4P Order Information CDB9 18mm Miniature Circuit Breaker Standard:IEC 60898-1 Trip Curve:B,C and D curves Breaking Capacity: 6000/10000A
  • 23. 014 Final Distribution Technical Date MCB CDB9 18mm Circuit Breaker Electrical Features Standard IEC 60898-1 Certification KEMA CB CE Poles l-4P Rated Current In l,2,4,6,10,16,20,25,32,40,50,63A Rated Voltage Ue 230/400V AC Insulation Voltage Ui 500V Breaking Capacity Icn Rate Current(A) Breaking Capacity Icn(kA) Type Poles Voltage (V) 1-63 6 B,C,D 1P 230/400 2P,3P,4P 400 1-63 10 B,C,D 1P 230/400 2P,3P,4P 400 Tripping Curve(see following tripping curve pictures) B curve; the magnetic release operates between 3 and 5 In C curve; the magnetic release operates between 5 and 10 In D curve; the magnetic release operates between 10 and 14 In Mechanical Features Electrical Durability 10000 times Mechanical Durability 20000 times Protection Degree 2 Ambient Temperture -30 °C~+70°C Connection 1-32A Up to 25mm² cables 40-63 Up to 35mm² cables lnstallation Rate Current(A) Screw Rated Torque(Nm) Limiting Torque(Nm) 1-32 M5 2.0 2.5 40-63 M6.5 3.5 2.5 Mounting 35mm Din-rail Accessories Contact Accessory OF Fault-Indicating Accessory SD Shunt-Trip Release MX+OF CDB9 18mm Miniature Circuit Breaker Standard:IEC 60898-1 Trip Curve:B,C and D curves Breaking Capacity: 6000/10000A
  • 24. 015 Final Distribution Tripping Curve Overall Dimensions Accessories CDB9 18mm Miniature Circuit Breaker Standard:IEC 60898-1 Trip Curve:B,C and D curves Breaking Capacity: 6000/10000A
  • 25. 016 Final Distribution Function 63 80 100 125 6 6 6 6 2P CDB2H2D63 CDB2H2D80 CDB2H2D100 CDB2H2D125 CDB2H2C63 CDB2H2C80 CDB2H2C100 CDB2H2C125 63 80 100 125 9 9 9 9 3P CDB2H3D63 CDB2H3D80 CDB2H3D100 CDB2H3D125 CDB2H3C63 CDB2H3C80 CDB2H3C100 CDB2H3C125 63 80 100 125 12 12 12 12 4P CDB2H4C63 CDB2H4C80 CDB2H4C100 CDB2H4C125 CDB2H4D63 CDB2H4D80 CDB2H4D100 CDB2H4D125 Type Rating (A) Width (in mod.of 9mm) Reference C curve D curve 63 80 100 125 3 3 3 3 CDB2H1D63 CDB2H1D80 CDB2H1D100 CDB2H1D125 1P CDB2H1C63 CDB2H1C80 CDB2H1C100 CDB2H1C125 Order Information CDB2 miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation CDB2 27mm Miniature Circuit Breaker Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A
  • 26. 017 Final Distribution Technical Data CDB2 27mm Miniature Circuit Breaker Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A 1-4P 63,80,100,125A 230/400V AC 500V IEC60947-2 CB, SEMKO, CE, RoHS Accessories Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Mounting Installation Connection Mechanical Features Electrical Features Rating (A) Rate current(A) Contact Accessory: Shunt-trip Release: OF MX+OF 63-125 M7 4 5.5 63~125 1P 2P,3P,4P 230 400 10 10 Poles Screw Voltage (V) Rated Torque (Nm) Breaking capacity (kA) Limiting Torque (Nm) MCB CDB2 27mm Circuit Breaker Breaking Capacity Icn Up to 50mm2 cables 35mm Din-rail Tripping Curve (see following tripping curve pictures) (C curve the magnetic release operates between 5 and 10 In) (D curve the magnetic release operates between 10 and 14 In) Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature 2 treatment 2 -5°C ~ +40°C
  • 27. 018 Final Distribution CDB2 27mm Miniature Circuit Breaker Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A MX+OF OF CDB2 Tripping Curves Overall Dimensions Accessories
  • 28. 019 Final Distribution Function CDB6p Phase-neutral Circuit Breaker Standard: IEC 60898-1 Trip Curve: C curve Breaking Capacity: 4500A Order Information CDB6p phase-neutral circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control 6 10 16 20 25 32 2 2 2 2 2 2 CDB6pC6 CDB6pC10 CDB6pC16 CDB6pC20 CDB6pC25 CDB6pC32 1P+N Technical Data IEC60898-1 CB 1P+N 6,10,16,20,25,32A 230V AC 500V 4.5KA Breaking Capacity Icn Tripping Curve (see following tripping curve pictures) C curve:the magnetic release operates between 5 and 10In Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 6-32 M4 2 3 Electrical Features 2 treatment 2 -5℃~+40℃ Protection Degree Ambient Temperature Tropicalization 4000 times 16000 times Electrical Durability Mechanical Durability Up to 10mm cables 2 35mm Din-rail Mechanical Features MCB Connection Installation Mounting CDB6p Phase-neutral Circuit Breaker Function
  • 29. 020 Final Distribution 45 18 78 88max 35 5.5 70max CDB6p Phase-neutral Circuit Breaker Tripping Curve CDB6p Phase-neutral Circuit Breaker Standard: IEC 60898-1 Trip Curve: C curve Breaking Capacity: 4500A Overall Dimensions
  • 30. 021 Final Distribution Function Electrical Features Order Information Technical Data Mechanical Features MCB Connection Installation Mounting CDB3 Phase-neutral Circuit Breaker Tripping Curve (see following tripping curve pictures) Up to 10mm2 cables 35mm Din-rail C curve:the magnetic release operates between 5 and 10In CDB3 Phase-neutral Circuit Breaker Standard: IEC 60898-1 Trip Curve: C curves Breaking Capacity: 3000A Standard Certification Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Icn Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature 4000 times 16000 times 2 treatment 2 -5°C ~ +40°C Rate current(A) 6-32 M4 2 3 Screw Rated Torque (Nm) Limiting Torque (Nm) IEC60898-1 CE 1P+N 6,10,16,20,25,32A 230V AC 500V 3kA CDB3 phase-neutral circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation 6 10 16 20 25 32 2 2 2 2 2 2 CDB3a5C6 CDB3a5C10 CDB3a5C16 CDB3a5C20 CDB3a5C25 CDB3a5C32 1P+N
  • 31. 022 Final Distribution CDB3 Phase-neutral Circuit Breaker Standard: IEC 60898-1 Trip Curve: C curves Breaking Capacity: 3000A Overall Dimensions Tripping Curves 10000 5000 2000 1h 1000 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.005 0.02 0.002 0.01 0.001 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200
  • 32. 023 Final Distribution Type 1P 3P 4P 2P Width (in mod.of 9mm) 2 2 2 2 6 6 6 6 8 8 8 8 4 4 4 4 Reference CDB6IS120 CDB6IS132 CDB6IS163 CDB6IS1100 CDB6IS320 CDB6IS332 CDB6IS363 CDB6IS3100 CDB6IS420 CDB6IS432 CDB6IS463 CDB6IS4100 CDB6IS220 CDB6IS232 CDB6IS263 CDB6IS2100 Rating (A) 20 32 63 100 20 32 63 100 20 32 63 100 20 32 63 100 Order Information Standard: IEC 60947-3 CDB6IS Switch Disconnector Making and breaking normal load circuits Isolation CDB6IS switch disconnectors combine the following functions: Function 2 CDB6IS1125 125 4 CDB6IS2125 125 6 CDB6IS3125 125 8 CDB6IS4125 125
  • 33. 024 Final Distribution Standard: IEC 60947-3 CDB6IS Switch Disconnector Technical Data Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 20-125 M7 4 5.5 l CDB6IS Switch Disconnector r Standard Capacity for 1s Protection Degree Ambient Temperature Tropicalization Up to 50mm cables 2 35mm Din-rai Overall Dimensions Electrical Durability Mechanical Durability 2 - 5 。 C ~ +40 。 C treatment 2 1500 times 8500 times Switch Disconnector Electrical Features 20, 32, 63, 100,125A 500V IEC60947-3 12le 1-4P 230/400V AC Short-time Withstand Connection Installation Mounting Mechanical Features Certification CB,CE,SEMKO
  • 34. 025 Final Distribution Type Voltage (V) 1P 230/400 3P 400 4P 400 2P Width (in mod.of 9mm) 2 2 2 2 6 6 6 6 8 8 8 8 4 4 4 4 400 Reference CDB5120 CDB5132 CDB5163 CDB51100 CDB5320 CDB5332 CDB5363 CDB53100 CDB5420 CDB5432 CDB5463 CDB54100 CDB5220 CDB5232 CDB5263 CDB52100 Rating (A) 20 32 63 100 20 32 63 100 20 32 63 100 20 32 63 100 Order Information Standard: IEC 60947-3 CDB5 Switch Disconnector CDB5 switch disconnectors combine the following functions: Making and breaking normal load circuits Isolation Function
  • 35. 026 Final Distribution Standard: IEC 60947-3 CDB5 Switch Disconnector Overall Dimensions Technical Data 1500 times 8500 times 2 -5°C ~ +40°C treatment 2 -25°C ~+55°C Standard Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Rated Short-circuit Making Capacity Short-time Withstand Capacity for 1s Electrical Durability Mechanical Durability Protection Degree Ambient Temperature Tropicalization Storage Temperature IEC60947-3 1-4P 20, 32, 63, 100A 230/400V AC 500V 1066A(Ie:20~63A) 1692A(Ie:100A), Peak current 756A(Ie:20~63A) 1200A(Ie:100A) Connection Installation Mounting Mechanical Features Electrical Features Switch Disconnector CDB5 Switch Disconnector Up to 50mm2 cables Rate current(A) 20-100 M7 4 35mm Din-rail 5.5 Screw Rated Torque (Nm) Limiting Torque (Nm)
  • 36. 027 Final Distribution CDG9 Switch Disconnector Standard:IEC 60947-3 Function CDG9 switch disconnectors combine the folIowing functions: ● Making and breaking normal load circuits ● Isolation Type Rating(A) Width (in mod.of 9mm) Reference 1P 32 2 CDG9125132 63 2 CDG9125163 100 2 CDG91251100 125 2 CDG91251125 2P 32 4 CDG9125232 63 4 CDG9125263 100 4 CDG91252100 125 4 CDG91252125 3P 32 6 CDG9125332 63 6 CDG9125363 100 6 CDG91253100 125 6 CDG91253125 4P 32 8 CDG9125432 63 8 CDG9125463 100 8 CDG91254100 125 8 CDG91254125 Order Information
  • 37. 028 Final Distribution CDG9 Switch Disconnector Standard:IEC 60947-3 Overall Dimensions Switch Disconnector CDG9 Switch Disconnector Electrical Features Standard IEC 60947-3 Certification CB,CE,TUV Poles 1-4P Rated Current In 32,63,100,125A Rated Voltage Ue 230/400VAC Insulation Voltage Ui 500V Short-time Withstand Current for 1s 12le Mechanical Features Electrical Durability 10000 times Mechanical Durability 20000 times Protection Degree 2 Ambient Temperture -30 °C~+70°C Tropicalization treatment 2 Connection Up to 50mm² cables lnstallation Rate current(A) Screw Rated Torque(Nm) Limiting Torque(Nm) 32-125 M6.5 3.5 3.5 Mounting 35mm Din-rail Technical Date
  • 38. 029 Final Distribution 030 036 043 044 039 041 033 Residual Current Devices Overview Sensitivity: 30,50,100,200,300mA In: 6-60A Breaking Capacity: 3kA Poles: 1P+N, 2P, 3P, 3P+N, 4P Sensitivity: 30,100,300mA In: V32A, V63A Poles: 1P+N, 2P, 3P, 3P+N, 4P Sensitivity: 30,100,300mA In: 63-100A Breaking Capacity: 10kA Poles: 1P+N, 2P, 3P, 3P+N, 4P Sensitivity:30mA Breaking Capacity:6000A Poles: 1P+N Sensitivity:30,100,300mA In: 10-100A Poles: 2P,4P Sensitivity: 30mA In: 6-40A Breaking Capacity: 4.5kA Poles: 1P+N Sensitivity: 30mA In: 6-40A Breaking Capacity: 4.5kA Poles: 1P+N 18mm RCBO 27mm RCBO Add-on RCD Phase-neutral RCBO CDB6LE CDB2LE CDL6SP CDB6VR CDB6pLE CDB3LE CDB6v RCCB
  • 39. 030 Final Distribution Function CDB6LE Residual Current Operated Circuit Breaker CDB6LE electronic type residual current operated circuit breakers combine the following functions: Overload protection Protection against short-circuit currents Protection for users against indirect currents Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation 400 400 230 230 3P+N 3P 2P 1P+N 30 30 30 30 11 11 11 11 11 11 14 14 14 10 10 10 10 10 10 12 12 12 7 7 7 7 7 7 8 8 8 5 5 5 5 5 5 6 6 6 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 CDB6LEa3C6S CDB6LEa3C10S CDB6LEa3C16S CDB6LEa3C20S CDB6LEa3C25S CDB6LEa3C32S CDB6LEa3C40S CDB6LEa3C50S CDB6LEa3C60S CDB6LEa2C6S CDB6LEa2C10S CDB6LEa2C16S CDB6LEa2C20S CDB6LEa2C25S CDB6LEa2C32S CDB6LEa2C40S CDB6LEa2C50S CDB6LEa2C60S CDB6LEa1C6S CDB6LEa1C10S CDB6LEa1C16S CDB6LEa1C20S CDB6LEa1C25S CDB6LEa1C32S CDB6LEa1C40S CDB6LEa1C50S CDB6LEa1C60S CDB6LEa6C6S CDB6LEa6C10S CDB6LEa6C16S CDB6LEa6C20S CDB6LEa6C25S CDB6LEa6C32S CDB6LEa6C40S CDB6LEa6C50S CDB6LEa6C60S CDB6LEa3D6S CDB6LEa3D10S CDB6LEa3D16S CDB6LEa3D20S CDB6LEa3D25S CDB6LEa3D32S CDB6LEa3D40S CDB6LEa3D50S CDB6LEa3D60S CDB6LEa1D6S CDB6LEa1D10S CDB6LEa1D16S CDB6LEa1D20S CDB6LEa1D25S CDB6LEa1D32S CDB6LEa1D40S CDB6LEa1D50S CDB6LEa1D60S CDB6LEa6D6S CDB6LEa6D10S CDB6LEa6D16S CDB6LEa6D20S CDB6LEa6D25S CDB6LEa6D32S CDB6LEa6D40S CDB6LEa6D50S CDB6LEa6D60S CDB6LEa2D6S CDB6LEa2D10S CDB6LEa2D16S CDB6LEa2D20S CDB6LEa2D25S CDB6LEa2D32S CDB6LEa2D40S CDB6LEa2D50S CDB6LEa2D60S Type Width Reference C curve D curve Voltage (V) Sensitivity (mA) Rating (A) Order Information Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W";100mA is marked with "Y";200mA is marked with "R";300mA is marked with "T". Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA
  • 40. 031 Final Distribution Type Width Reference C curve D curve Voltage (V) Sensitivity (mA) Rating (A) Order Information 400 4P 30 CDB6LEa4C6S CDB6LEa4C10S CDB6LEa4C16S CDB6LEa4C20S CDB6LEa4C25S CDB6LEa4C32S CDB6LEa4C40S CDB6LEa4C50S CDB6LEa4C60S CDB6LEa4D6S CDB6LEa4D10S CDB6LEa4D16S CDB6LEa4D20S CDB6LEa4D25S CDB6LEa4D32S CDB6LEa4D40S CDB6LEa4D50S CDB6LEa4D60S 6 10 16 20 25 32 40 50 60 13 13 13 13 13 13 16 16 16 CDB6LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA Note: 1. Width sensitivity refers to multiple of 9 mm. 2. If the sensitivity is 30mA,it's marked with "S" in the reference number.Also, 50mA is marked with "W";100mA is marked with "Y";200mA is marked with "R";300mA is marked with "T". Technical Data Installation Mounting Accessories Connection Mechanical Features Electrical Features Standard Electronic Type Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Sensitivity RCBO CDB6LE Residual Current Operated Circuit Breaker Tripping Curve(see following tripping curve pictures) 6-32A,Up to 16mm2 cables, 40-60A,Up to 25mm2 cables 35mm Din-rail Contact Accessory: Fault-indicating Accessory: OF SD C curve:the magnetic release operates between 5 and 10 D curve:the magnetic release operates between 10 and 14 Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature 2000 times 2000 times 2 treatment 2 -5°C ~ +40°C IEC 61009-1 AC 1P+N,2P,3P,3P+N,4P 6,10,16,20,25,32,40,50,60A 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P 500V 3KA 30,50,100,200,300mA Rate current(A) 6-32 40-60 M4 M5 2.0 2.5 3.0 4.5 Screw Rated Torque (Nm) Limiting Torque (Nm)
  • 41. 032 Final Distribution CDB6LE-60 CDB6LE-32 CDB6LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 3000A Sensitivity: 30,50,100,200,300mA Tripping Curves Accessories CDB6LE OF SD Overall Dimensions
  • 42. 033 Final Distribution Order Information Function CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked "G" Note: Width refers to mutultiple of 9mm. CDB6v Residual Current Protection Module Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Frame Type Voltage (V) Sensitivity (mA) Width Reference V32 1P+N 230 30 5 CDB6v321N 100 5 CDB6v321NR100 300 5 CDB6v321NR300 2P 230 30 7 CDB6v322P 100 7 CDB6v322PR100 300 7 CDB6v322PR300 3P 400 30 10 CDB6v323P 100 10 CDB6v323PR100 300 10 CDB6v323PR300 3P+N 30 11 CDB6v323N 100 11 CDB6v323NR100 300 11 CDB6v323NR300 4P 30 13 CDB6v324P 100 13 CDB6v324PR100 300 13 CDB6v324PR300 V63 1P+N 230 30 6 CDB6v631N 100 6 CDB6v631NR100 300 6 CDB6v631NR300 2P 230 30 8 CDB6v632P 100 8 CDB6v632PR100 300 8 CDB6v632PR300 3P 400 30 12 CDB6v633P 100 12 CDB6v633PR100 300 12 CDB6v633PR300 3P+N 30 14 CDB6v633N 100 14 CDB6v633NR100 300 14 CDB6v633NR300 4P 30 16 CDB6v634P 100 16 CDB6v634PR100 300 16 CDB6v634PR300
  • 43. 034 Final Distribution Technical Data CDB6v Residual Current Protection Module Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Mechanical Features Connection Installation Electrical Features Standard Electronic Type Poles Rated Current In Rated Voltage Ue Rated Insulation Voltage Breaking Capacity Sensitivity Tripping Indication Manual Control IEC61009-1 AC 1P+N, 2P, 3P, 3P+N, 4P V32 In≤32A V63 In≤63A 230/400V AC 500V after CDB6s assembled with reference to CDB6s parameters 30,100,300mA On CDB6v is a residual opening current indication, which distinguish residual current from other faults Manual control:allows for two kinds of reset CDB6v resets at the same time with breaker CDB6v resets before breaker “G” products offer overvoltage protection Electrical Durability Mechanical Durability Protection Degree Tropicaliation Ambient Temperature 2000 times(In≤25A) 1000times(In>25A) 2000 times IP20 treatrment 2 -5°C ~ +40°C Rate current(A) V32 V63 M4 M5 2.2 2.5 3.0 4.5 Screw Rated Torque (Nm) Limiting Torque (Nm) -Up to 16mm2 cables(V32) -Up to 25mm2 cables(V63) 280V±5% AC,applicable to products with 1P+N and 2P RCBO CDB6v Residual Current Protection Module
  • 44. 035 Final Distribution CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacts Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked“G” CDB6v Residual Current Protection Module Standard: IEC 61009-1 Electronic type: AC Sensitivity: 30,100,300mA Overall Dimensions Assembly + V32 Pole V63 1P+N 2P 3P 3P+N 4P 45±0.32 63±0.37 90±0.5 99±0.5 117±0.57 54±0.37 72±0.43 108±0.57 126±0.64 144±0.72
  • 45. 036 Final Distribution 3P 63 80 100 63 80 100 63 80 100 30 30 30 100 100 100 300 300 300 12 CDB2LEH3D63S CDB2LEH3D80S CDB2LEH3D100S CDB2LEH3D63Y CDB2LEH3D80Y CDB2LEH3D100Y CDB2LEH3D63T CDB2LEH3D80T CDB2LEH3D100T CDB2LEH3C63S CDB2LEH3C80S CDB2LEH3C100S CDB2LEH3C63Y CDB2LEH3C80Y CDB2LEH3C100Y CDB2LEH3C63T CDB2LEH3C80T CDB2LEH3C100T 63 80 100 63 80 100 63 80 100 30 30 30 100 100 100 300 300 300 6 CDB2LEH1D63S CDB2LEH1D80S CDB2LEH1D100S CDB2LEH1D63Y CDB2LEH1D80Y CDB2LEH1D100Y CDB2LEH1D63T CDB2LEH1D80T CDB2LEH1D100T CDB2LEH1C63S CDB2LEH1C80S CDB2LEH1C100S CDB2LEH1C63Y CDB2LEH1C80Y CDB2LEH1C100Y CDB2LEH1C63T CDB2LEH1C80T CDB2LEH1C100T 1P+N 63 80 100 63 80 100 63 80 100 30 30 30 100 100 100 300 300 300 9 CDB2LEH2D63S CDB2LEH2D80S CDB2LEH2D100S CDB2LEH2D63Y CDB2LEH2D80Y CDB2LEH2D100Y CDB2LEH2D63T CDB2LEH2D80T CDB2LEH2D100T CDB2LEH2C63S CDB2LEH2C80S CDB2LEH2C100S CDB2LEH2C63Y CDB2LEH2C80Y CDB2LEH2C100Y CDB2LEH2C63T CDB2LEH2C80T CDB2LEH2C100T 2P 3P+N 63 80 100 63 80 100 63 80 100 30 30 30 100 100 100 300 300 300 12 CDB2LEH6D63S CDB2LEH6D80S CDB2LEH6D100S CDB2LEH6D63Y CDB2LEH6D80Y CDB2LEH6D100Y CDB2LEH6D63T CDB2LEH6D80T CDB2LEH6D100T CDB2LEH6C63S CDB2LEH6C80S CDB2LEH6C100S CDB2LEH6C63Y CDB2LEH6C80Y CDB2LEH6C100Y CDB2LEH6C63T CDB2LEH6C80T CDB2LEH6C100T Type Width Reference C curve Rating (A) Sensitivity (mA) D curve Order Information Function CDB2LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Protection of electrical installations against insulation faults (fire hazard, etc) Isolation CDB2LE Residual Current Operated Circuit Breaker Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Note: Width refers to multiple of 9mm .
  • 46. 037 Final Distribution CDB2LE Residual Current Operated Circuit Breaker 4P 63 80 100 63 80 100 63 80 100 30 30 30 100 100 100 300 300 300 15 CDB2LEH4D63S CDB2LEH4D80S CDB2LEH4D100S CDB2LEH4D63Y CDB2LEH4D80Y CDB2LEH4D100Y CDB2LEH4D63T CDB2LEH4D80T CDB2LEH4D100T CDB2LEH4C63S CDB2LEH4C80S CDB2LEH4C100S CDB2LEH4C63Y CDB2LEH4C80Y CDB2LEH4C100Y CDB2LEH4C63T CDB2LEH4C80T CDB2LEH4C100T Note: Width refers to multiple of 9mm . Technical Data Type Width Reference C curve Rating (A) Sensitivity (mA) D curve Order Information Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Electrical Features Standard Electronic Type Poles Rated Current In Rated Voltage Ue Insulation Voltage Breaking Capacity Ui Sensitivity IEC60947-2 AC 1P+N,2P,3P,3P+N,4P 63,80,100A 230V for 1P+N; 400V for 2P/3P/3P+N/4P 500V 10KA 30,100,300mA RCBO CDB2LE Residual Current Operated Circuit Breaker Tripping Curve ( see following tripping curve pictures) C curve:the magnetic release operated between 5 and 10 In D curve:the magnetic release operated between 10 and 14 In Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature Contact Accessory: Shunt -trip Release: OF MX+OF Rate current(A) 63-100 M7 4 5.5 Screw Rated Torque (Nm) Limiting Torque (Nm) Up to 50mm2 cables 1500 times 8500 times 2 treatment 2 -5°C ~ +40°C Mechanical Features Connection Installation Accessories
  • 47. 038 Final Distribution CDB2LE Residual Current Operated Circuit Breaker Overall Dimensions Accessories Standard: IEC 60947-2 Electronic type: AC Breaking Capacity: 10000A Sensitivity: 30, 100, 300mA Tripping Curve MX+OF OF CDB2LE
  • 48. 039 Final Distribution CDB6pLEResidualCurrentOperatedCircuitBreaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA RCBO CDB6pLE Residual Current Operated Circuit Breaker Tripping Curve (see following tripping curve pictures) C curve:the magnetic release operates between 5 and 10 In Connection Installation Mounting 35mm Din-rail Rate current(A) Screw Rated Torque (Nm) Limiting Torque (Nm) 6-40 M5 2.5 4.5 IEC61009-1 AC 1P+N 6,10,16,20,25,32,40A 230V AC 500V 4.5KA 30mA Standard Electronic Type Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Sensitivity Protection Degree Tropicalization Ambient Temperature 2000 times 4000 times 2 treatment 2 -5℃~+40℃ 2 Up to 25mm cables Function CDB6pLE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contacts Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation Type 1P+N Width (mm) 36 Rating(A) 6 10 16 20 25 32 40 CDB6pLEC6 CDB6pLEC10 CDB6pLEC16 CDB6pLEC20 CDB6pLEC25 CDB6pLEC32 CDB6pLEC40 Reference C curve Order Information Technical Data Mechanical Features Electrical Features Electrical Durability Mechanical Durability CB Certification
  • 49. 040 Final Distribution Overall Dimensions Tripping Curve CDB6pLE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA CDB6pLE Residual Current Operated Circuit Breaker
  • 50. 041 Final Distribution Function CDB3LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA CDB3LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation Type 1P+N Width (mm) 36 Rating(A) 6 10 16 20 25 32 40 CDB3LEL5C6S CDB3LEL5C10S CDB3LEL5C16S CDB3LEL5C20S CDB3LEL5C25S CDB3LEL5C32S CDB3LEL5C40S Reference C curve Order Information Technical Data Mechanical Features Rate current(A) 6-40 M5 2.5 4.5 Screw Rated Torque (Nm) Limiting Torque (Nm) Connection Installation Mounting Electrical Features Standard Electronic Type Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Breaking Capacity Sensitivity Electrical Durability Mechanical Durability Protection Degree Tropicalization Ambient Temperature 2000 times 2000 times 2 treatment 2 -5°C ~ +40°C IEC61009-1 AC 1P+N 6,10,16,20,25,32,40A 230V AC 500V 4.5KA 30mA CDB3LE Residual Current Operated Circuit Breaker Tripping Curve (see following tripping curve pictures) Up to 16mm2 cables 35mm Din-rail C curve:the magnetic release operates between 5 and 10 In RCBO
  • 51. 042 Final Distribution Overall Dimensions Tripping Curve CDB3LE Residual Current Operated Circuit Breaker Standard: IEC 61009-1 Electronic type: AC Breaking Capacity: 4500A Sensitivity: 30mA
  • 52. 043 Final Distribution Standard:IEC61009-1 Breaking Capacity:6000A Sensitivity:30mA CDL6SPResidual Current Operated Circuit Breaker Order Information Technical information Poles Rating (A) Sensitivity Reference B Curve C Curve 1P+N 6 30mA CDL6SPN5B6S CDL6SPN5C6S 10 30mA CDL6SPN5B10S CDL6SPN5C10S 16 30mA CDL6SPN5B16S CDL6SPN5C16S 20 30mA CDL6SPN5B20S CDL6SPN5C20S 25 30mA CDL6SPN5B25S CDL6SPN5C25S 32 30mA CDL6SPN5B32S CDL6SPN5C32S 40 30mA CDL6SPN5B40S CDL6SPN5C40S Function CDL6SP Single phase residual current operated circuit breaker can offer earth leakage protection. Usually it can be used with CDB6S. Standard IEC61009 Breaking Capacity 6KA Poles 1P+N Rated Current 6,10,16,20,25,32,40A Rated Voltage 230VAC Rated Tripping Current 10mA Residual Current off time ≤0.1s Characteristic B.C Electrical endurance 10000 Mechanical endurance 20000 Protection degree ﹣25℃~40℃ Connection terminal Flexible conductor 16mm 2 Rigid conductor 25mm 2 Type of terminal Lug type and Pin type Overall Dimensions
  • 53. 044 Final Distribution CDB6VR Residual Current Operated Circuit Breaker Standard:IEC 61008-1 RCCB Type: A , C A Sensitivity: 30, 100, 300mA Final Distribution Final Distribution CDB6VR Residual current operated circuit breakers combine the fo llowing functions: Protection for users against indirect contacts Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Function Order Information 4 2P 10 63AF 30 100 300 16 DB6VR210SC DB6VR210YC DB6VR210TC C C C 4P 30 100 300 25 C C C DB6VR216SC DB6VR216YC DB6VR216TC 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 8 40 63 80 100 10 100AF 63AF C C C C C C C C C C C C C C C DB6VR225SC DB6VR225YC DB6VR225TC DB6VR240SC DB6VR240YC DB6VR240TC DB6VR263SC DB6VR263YC DB6VR263TC DB6VR280SC DB6VR280YC DB6VR280TC DB6VR2100SC DB6VR2100YC DB6VR2100TC 30 100 300 16 C C C C C C C C C C C C C C C C C C C C C C C C C C C DB6VR410SC DB6VR410YC DB6VR410TC 30 100 300 25 C C C DB6VR416SC DB6VR416YC DB6VR416TC 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 40 63 80 100 100AF C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C DB6VR425SC DB6VR425YC DB6VR425TC DB6VR440SC DB6VR440YC DB6VR440TC DB6VR463SC DB6VR463YC DB6VR463TC DB6VR480SC DB6VR480YC DB6VR480TC DB6VR4100SC DB6VR4100YC DB6VR4100TC DB6VR210SA DB6VR210YA DB6VR210TA DB6VR216SA DB6VR216YA DB6VR216TA DB6VR225SA DB6VR225YA DB6VR225TA DB6VR240SA DB6VR240YA DB6VR240TA DB6VR263SA DB6VR263YA DB6VR263TA DB6VR280SA DB6VR280YA DB6VR280TA DB6VR2100SA DB6VR2100YA DB6VR2100TA DB6VR410SA DB6VR410YA DB6VR410TA DB6VR416SA DB6VR416YA DB6VR416TA DB6VR425SA DB6VR425YA DB6VR425TA DB6VR440SA DB6VR440YA DB6VR440TA DB6VR463SA DB6VR463YA DB6VR463TA DB6VR480SA DB6VR480YA DB6VR480TA DB6VR4100SA DB6VR4100YA DB6VR4100TA
  • 54. 045 Final Distribution Standard: IEC 61008-1 RCCB Type: AC,A Sensitivity: 30, 100, 300mA CDB6VR Residual Current Operated Circuit Breaker Overall Dimensions RCCB Connection Installation Mounting 35mm Din-rail Standard Certification Type IEC 61008-1 TUV,CE,CB AC,A 2P、4P 230/400V AC 500V 30,100,300mA no Poles Rated Current In Rated Voltage Ue Insulation Voltage Ui Sensitivity 1000 times 2000 times Tripping Indication Fault Curren Indicator Mechanical indication in the front Protection Degree 2 Tropicalization Up to 25mm 2 cables(In>63A) Up to 35mm 2 Treatment 2 Ambient Temperature -25 ~+40 Screw Rate current(A) Rated Torque (Nm) Limiting Torque (Nm) 25-100 M5 2.0 4.5 No need Overload or Short Circuit Protection Instantaneous, rated residual operated current, unadjustable 10,16,25,32,40,63,80, Mechanical Features Electrical Features Power source Auxilary A y Mechanical Durability Electrical Durabilit , 100 CDB6VR-63 CDB6VR-100 CDB6VR Residual Current Operated Circuit Breaker 4P 2P 36 61.7 72 70±0.6 43.5±0.6 5.5 35.4 45 78.5
  • 55. 046 Final Distribution The sketch map of installation with breaker SD OF Breaker MX+OF SD OF MX+OF Accessories CDB6,CDB6LE Order Information type Width(mm) Voltage(V) Reference OF 9 CDB6OF SD 9 CDB6SD MX+OF 18 18 18 18 18 18 18 CDB6MX110 CDB6MX130 CDB6MX230 CDB6MX400 CDB6MX12 CDB6MX24 CDB6MX48 AC 110V AC 130V AC 230V AC 400V AC/DC 12V AC/DC 24V AC/DC 48V Connection: 1-4mm2 cables Remote Control Auxiliaries OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables SD fault-indicating switch Indicator on the front to show fault trip Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Tripping Device OF, SD must be assembled on the left ,one auxiliary only Each time only one auxiliary accepted in the left of MCB MX+OF must be assembled on the right, one MX+OF only CDB6LE can't assemble MX+OF Introductions Sent out fault signal on the front when breaking down MX+OF must be assembled on the right, one MX+OF only
  • 56. 047 Final Distribution CDB9,CDB9LE Accessoriess The sketch map of installation with breakers Remote Control Auxiliaries Tripping Device Introductions ■ OF contact auxiliary ● Indicate ON or OFF state of the breaker ● Basic type of auxiliary contact: 1NO+INC ■ SD fault-indicating switch ● Sent out fault signal on the font when breaking down ● Indicator on the front to show fault trip ● Basic type of auxiliary contact: 1NO+1NC ■ MX+OF shunt trip release ● Indicate ON or OFF state of the breaker ● Without tools ,directly installed on the left of MCB ■ Without tools ,direct installed on the left of MCB ■ Each MCB maximum assembles 3 control auxiliaries(OF or SD) Type Width(mm) Voltage(V) Reference 9 CDB963OF 9 CDB963SD 18 AC/DC 12/24V CDB963MX24 18 AC/DC 48V CDB963MX48 18 AC 100-415V DC 110-130V CDB963MX415 Order Information Accessories
  • 57. 048 Final Distribution Accessories CDB6s type Width(mm) Voltage(V) Reference OF 9 CDB6sOF SD 9 CDB6sSD The sketch map of installation with breakers SD fault-indicating switch Sent out fault signal when breaking down Indicator on the front to show fault trip Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables OF,SD must be assembled on the left ,one auxiliary only Each time only one auxiliary accepted in the left of MCB MX+OF must be assembled on the right, one MX+OF only CDB6s can't assemble MX+OF while assembled with CDB6v SD OF MX+OF CDB6s Order Information Introductions OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip while given signal Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables Tripping Device Remote Control Auxiliaries MX+OF 1 CDB6sMX24 CDB6sMX48 CDB6sMX110 CDB6sMX230 18 18 18 18 AC230-400V AC/DC12-24V AC/DC24-48V AC110-127V MX+OF must be assembled on the right, one MX+OF only
  • 58. 049 Final Distribution CDB2,CDB2LE The sketch map of installation with breakers MX+OF OF Breaker OF contact auxiliary Indicate ON or OFF state of the breaker Basic type of auxiliary contact:2NO+2NC Connection: 1-4mm2 cables MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables Tripping Device Remote Control Auxiliaries MX+OF, OF must be assembled on the left Each time only one auxiliary accepted in the left of MCB Introductions Type Width(mm) Description Reference OF 18 1NO 1NC CDB2OF11 18 2NO 2NC CDB2OF22 MX+OF 18 CDB2MX24 18 AC48V~130V DC48V CDB2MX48 18 AC230V-400V DC110V-130V CDB2MX230 Order Information AC/DC24V Accessories OF must be assembled on the left
  • 59. 050 Final Distribution Technical Data Busbar A A A A A A A A Order Information PIN-TYPE U-TYPE Terminal Adaptor CBBA805 1 2 3 4 1 2 3 4 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 10 16 10 16 10 16 10 16 10 16 10 16 10 16 10 16 63 80 63 80 63 80 63 80 63 80 63 80 63 80 63 80 Type Type Reference Dimension(mm) Pole Thickness of pin (mm) Section cross (mm2 ) Max. current(A) End feed-in A Reference Length Dimension(mm) 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m 1m CBB16315P CBB18015P CBB26315P CBB28015P CBB36315P CBB38015P CBB46315P CBB48015P CBB16315F CBB18015F CBB26315F CBB28015F CBB36315F CBB38015F CBB46315F CBB48015F Standard Material of busbar Material of insulation Short-circuit strength Nominal voltage Operating voltage Surge voltage Clima stability IEC 60664 E-CU-F25 PVC 50kA 415V Max 500V 4kV IEC 60068-2 7 11 7 11 7 11 7 11 7 11 7 11 7 11 7 11 . . . Accessories
  • 60. 051 Final Distribution CDCH8P Modular Contactor Standard: IEC 61095 Function Order Information CDCH8P Modular Contactor provide: Automatic control on equipment in buildings Switch on or Switch off lighting or other equipments Pole Reference Current (A) Contacts 2P 16 2NO CDCH8P16220 1NO 1NC CDCH8P16211 20 2NO CDCH8P20220 1NO 1NC CDCH8P20211 25 2NO CDCH8P25220 1NO 1NC CDCH8P25211 32 2NO CDCH8P32220 2NC CDCH8P32202 1NO 1NC CDCH8P32211 40 2NO CDCH8P40220 2NC CDCH8P40202 1NO 1NC CDCH8P40211 63 2NO CDCH8P63220 2NC CDCH8P63202 1NO 1NC CDCH8P63211 4P 16 4NO CDCH8P16440 4NC CDCH8P16404 2NO 2NC CDCH8P16422 3NO 1NC CDCH8P16431 20 4NO CDCH8P20440 4NC CDCH8P20404 2NO 2NC CDCH8P20422 3NO 1NC CDCH8P20431 25 4NO CDCH8P25440 4NC CDCH8P25404 2NO 2NC CDCH8P25422 3NO 1NC CDCH8P25431 32 4NO CDCH8P32440 4NC CDCH8P32404 2NO 2NC CDCH8P32422 3NO 1NC CDCH8P32431 40 4NO CDCH8P40440 4NC CDCH8P40404 2NO 2NC CDCH8P40422 3NO 1NC CDCH8P40431 63 4NO CDCH8P63440 4NC CDCH8P63404 2NO 2NC CDCH8P63422 3NO 1NC CDCH8P63431
  • 61. 052 Final Distribution Technical information Standard IEC 61095 Ambient Temperature ﹣5℃~40℃ Rated Voltage Ue 230V AC Rated Insulation Voltage Ui 500V AC Operation Time ≥30000 times Coil Voltage (Us) 220/230V AC Type AC-7a AC-7b Rated Current (Ie) 20A/25A/32A/40A/63A 7A/8.5A/12A/15A/25A Rated Power 4kW/5.4kW/6.5kW/ 8.4kW/13kW 1.2kW/1.5kW/1.9kW/ 2.4kW/3.8kW Operation Frequency 1200times/h 30time/h Marking & Breaking Capacity 1.5Ie 8Ie CDCH8P Modular Contactor Standard: IEC 61095
  • 62. 053 Final Distribution 17.5 35 35 Overall Dimensions CDCH8P-2P, 16-25A CDCH8P-2P, 32-63A CDCH8P-4P, 16-25A CDCH8P-4P, 32-63A CDCH8P Modular Contactor Standard: IEC 61095
  • 63. 054 Final Distribution CDRT8 Time Relay Standard:IEC 60947.5 Order Information Technical Data CDRT8 Time Relay provide: Disconnect Delay Connect Delay Limit delay time Delay type Reference CDRT810B CDRT8120B CDRT8480A power delay power delay off delay 10 120 480 480 power delay CDRT8480B Standard Rated Voltage Ue Rated Current(le) Delay Type Timing Range Contact Type Contact Number Rated Control Supply Voltage(Us) Operating Voltage Range Rated Wattage Insulation Resistance Insulation Strength Connection Limit Delay Time Conventional Thermal Current(l ) CDRT8 Time Relay Building Control Command Devices up to 1mm cables 2 To each:AC 1760V 5s Disconnect between the contact position:AC 1000V 1min <1W > 85%-110%Us 230V AC 1 Normally open contact 8A 10s 120s 480s Off dalay Power delay 5A 230V AC th Electrical Durability 30000 times IEC 60947.5 Function
  • 64. 055 Final Distribution CDRT8 Time Relay Standard:IEC 60947.5 Wiring Diagram Overall Dimensions 19max
  • 65. 056 Final Distribution Function CDY1 Surge Protective Devices Standard: IEC61643 CDY1 surge protective devices provide: Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the circuit Order Information Imax (kA) Uc (V) Up (kV) Reference 1P 2P 3P 4P 1P+N 3P+N 20 275 1.3 CDY1201275 CDY1202275 CDY1203275 CDY1204275 CDY1205275 CDY1206275 385 1.5 CDY1201385 CDY1202385 CDY1203385 CDY1204385 CDY1205385 CDY1206385 420 1.8 CDY1201420 CDY1202420 CDY1203420 CDY1204420 CDY1205420 CDY1206420 40 275 1.5 CDY1401275 CDY1402275 CDY1403275 CDY1404275 CDY1405275 CDY1406275 385 1.8 CDY1401385 CDY1402385 CDY1403385 CDY1404385 CDY1405385 CDY1406385 420 2.0 CDY1401420 CDY1402420 CDY1403420 CDY1404420 CDY1405420 CDY1406420 60 275 1.8 CDY1601275 CDY1602275 CDY1603275 CDY1604275 CDY1605275 CDY1606275 385 2.2 CDY1601385 CDY1602385 CDY1603385 CDY1604385 CDY1605385 CDY1606385 420 2.5 CDY1601420 CDY1602420 CDY1603420 CDY1604420 CDY1605420 CDY1606420 80 275 2.0 CDY1801275 CDY1802275 CDY1803275 CDY1804275 CDY1805275 CDY1806275 385 2.2 CDY1801385 CDY1802385 CDY1803385 CDY1804385 CDY1805385 CDY1806385 420 2.5 CDY1801420 CDY1802420 CDY1803420 CDY1804420 CDY1805420 CDY1806420 100 275 2.2 CDY11001275 CDY11002275 CDY11003275 CDY11004275 CDY11005275 CDY11006275 385 2.5 CDY11001385 CDY11002385 CDY11003385 CDY11004385 CDY11005385 CDY11006385 420 2.5 CDY11001420 CDY11002420 CDY11003420 CDY11004420 CDY11005420 CDY11006420
  • 66. 057 Final Distribution CDY1 Surge Protective Devices Standard: IEC61643 Overall Dimensions Technical Data CDY1-80 CDY1-100 CDY1-60 CDY1-40 CDY1-20 1P, 1P+N, 2P, 3P, 3P+N, 4P 20 40 30 60 40 80 50 100 Type Pole Nominal discharge current In(8/20us) kA Maximum discharge current Imax(8/20us) kA Maximum continuous operational voltage Uc V Protection level Up kV Leakage current (75%Uc 1mA) uA Response time ns ≤20 ≤25 275 1.3 385 1.5 420 1.8 275 1.5 420 2.0 275 1.8 420 2.5 385 2.2 275 2.0 420 2.5 385 2.2 275 2.2 420 2.5 385 2.5 385 1.8 Standard: IEC 61643 Certification: SEMKO, CB 10 20
  • 67. 058 Final Distribution Function Order Information CDPZ50 Series Consumer Box Standard: IEC60439-1 IEC60670 CDPZ50 series Consumer Box provide: Protection against overload Protection against over voltage Protection against leakage Material Installation No.of loop Reference Metal box&Plastic Cover Surface installation 6 CDPZ50M6 8 CDPZ50M8 12 CDPZ50M1 2 16 CDPZ50M1 6 20 CDPZ50M20 24 CDPZ50M24 Flush installation 6 CDPZ50R6 8 CDPZ50R8 12 CDPZ50R1 2 16 CDPZ50R1 6 20 CDPZ50R20 24 CDPZ50R24 Material Installation No.of loop Reference Full Plastic 4 CDPZ50PM41P30F 6 CDPZ50PM61P30F 8 CDPZ50PM8IP30F 12 CDPZ50PM121P30F 15 CDPZ50PM151P30F 18 CDPZ50PM18IP30F 24 CDPZ50PM24IP30F 36 CDPZ50PM36IP30F 4 CDPZ50PR41P30F 6 CDPZ50PR61P30F 8 CDPZ50PR8IP30F 12 CDPZ50PR121P30F 15 CDPZ50PR151P30F 18 CDPZ50PR18IP30F 24 CDPZ50PR24IP30F 36 CDPZ50PR36IP30F Full Plastic Surface installation Non 4 CDPZ50PM41P30NF 6 CDPZ50PM61P30NF 8 CDPZ50PM8IP30NF 12 CDPZ50PM121P30NF 15 CDPZ50PM151P30NF 18 CDPZ50PM18IP30NF 24 CDPZ50PM24IP30NF 36 CDPZ50PM36IP30NF Flush installation Surface installation Flush installation 4 CDPZS0PR41P30NF 6 CDPZS0PR61P30NF 8 CDPZ50PR8IP30NF 12 CDPZ50PR121P30NF 15 CDPZ50PR151P30NF 18 CDPZ50PR18IP30NF 24 CDPZ50PR24IP30NF 36 CDPZ50PR36IP30NF
  • 68. 059 Final Distribution CDPZ50 Series Consumer Box Standard: IEC60439-1 IEC60670 Unit:mm Overall Dimensions CDPZ50 Surface installation A Thickness C 90 90 90 90 90 90 B 200 200 200 200 200 364 Flush installation A 163 199 272 343 413 282 B 220 220 220 220 220 383 171 207 279 351 423 303 6 8 12 16 20 24 Metal box&Plastic Cover Technical Data Full Plastic Optional Material Fire-resistancy Fire-resistancy Protection grade Rated operation voltage Rated insulated voltage Rated operating current Withstand current IP30 230/400V 500V 100A 6kA Box:Metal, Cover:Plastic CDPZ50 CDPZ50P Type Surface installation Flush installation CDPZ50P D E F H I A B C C1 Flush installation Surface installation Full plastic Loop number
  • 69. 060 Final Distribution Order Information Function JXF Metal Enclosure Standard: EN60529 JXF Metal Enclosure provide: Control, monitering, measurement and protection for the electric power loops and main power controlling equipment. Type Thickness of iron charge(mm) Dimension(mm) Lock Reference Overall Installation Mounting H W D H1 B1 H6 B6 Thick JXF一2520/14 lP43 Improved 1.0 250 200 140 290 150 170 158 1.0 1 JXF252014B JXF一3025/14 lP43 Improved 1.0 300 250 140 340 200 220 208 1.0 1 JXF302514B JXF一3025/18 lP43 Improved 1.0 300 250 180 340 200 220 208 1.0 1 JXF302518B JXF一3030/14 lP43 Improved 1.0 300 300 140 340 250 220 258 1.0 1 JXF303014B JXF一3030/18 lP43 Improved 1.0 300 300 200 340 250 220 258 1.0 1 JXF303018B JXF一4030/14 lP43 Improved 1.0 400 300 140 440 250 320 258 1.0 1 JXF403014B JXF一4030/20 lP43 Improved 1.0 400 300 200 440 250 320 258 1.0 1 JXF403020B JXF一5040/14 lP43 Improved 1.0 500 400 250 540 350 420 358 1.0 2 JXF504014B JXF一5040/20 lP43 Improved 1.0 500 400 140 540 350 420 358 1.0 2 JXF504020B JXF一5040/25 lP43 Improved 1.0 500 400 200 540 350 420 358 1.0 2 JXF504025B JXF一6040/14 lP43 Improved 1.2 600 400 250 640 350 520 358 1.2 2 JXF604014B JXF一6040/20 lP43 Improved 1.2 600 400 140 640 350 520 358 1.2 2 JXF604020B JXF一6040/25 lP43 Improved 1.2 600 400 200 640 350 520 358 1.2 2 JXF604025B JXF一6050/14 lP43 Improved 1.2 600 500 250 640 450 520 458 1.2 2 JXF605014B JXF一6050/20 lP43 Improved 1.2 600 500 140 640 450 520 458 1.2 2 JXF605020B JXF一6050/25 lP43 Improved 1.2 600 500 160 640 450 520 458 1.2 2 JXF605025B JXF一7050/16 lP43 Improved 1.2 700 500 200 740 450 620 458 1.2 2 JXF705016B JXF一7050/20 lP43 Improved 1.2 700 500 250 740 450 620 458 1.2 2 JXF705020B JXF一7050/25 lP43 Improved 1.2 700 500 200 740 450 620 458 1.2 2 JXF705025B JXF一8060/20 lP43 Improved 1.5 800 600 250 840 550 720 558 1.5 2 JXF806020B JXF一8060/25 lP43 Improved 1.5 800 600 250 840 550 720 558 1.5 2 JXF806025B JXF一10080/20 lP43 Improved 1.5 1000 800 200 1040 750 920 758 1.5 2 JXFl008020B JXF一10080/25 lP43 Improved 1.5 1000 800 250 1040 750 920 758 1.5 2 JXFl008025B JXF一10080/30 lP43 Improved 1.5 1000 800 300 1040 750 920 758 1.5 2 JXFl008030B JXF一2520/14 IP54 1.2 250 200 140 320 150 215 148 2.0 1 JXF252014Q JXF一3025/14 IP54 1.2 300 250 140 370 200 265 198 2.0 1 JXF302514Q JXF一3025/18 IP54 1.2 300 250 370 200 265 265 198 2.0 1 JXF302518Q JXF一3030/14 IP54 1.2 300 300 370 250 265 265 248 2.0 1 JXF303014Q JXF一3030/1 8 IP54 1.2 300 300 370 250 265 265 248 2.0 1 JXF30301 8Q JXF一4030/14 IP54 1.2 400 300 470 250 365 365 248 2.0 1 JXF403014Q JXF一4030/20 IP54 1.2 400 300 470 250 365 365 248 2.0 1 JXF403020Q JXF一5040/14 IP54 1.2 500 400 570 350 465 465 348 2.0 2 JXF504014Q JXF一5040/20 IP54 1.2 500 400 570 350 465 465 348 2.0 2 JXF504020Q JXF一5040/25 IP54 1.2 500 400 570 350 465 465 348 2.0 2 JXF504025Q JXF一6040/14 IP54 1.5 600 400 670 350 565 565 348 2.0 2 JXF604014Q JXF一6040/20 IP54 1.5 600 400 670 350 565 565 348 2.0 2 JXF604020Q JXF一6040/25 IP54 1.5 600 400 670 350 565 565 348 2.0 2 JXF604025Q JXF一6050/14 IP54 1.5 600 500 670 450 565 565 448 2.0 2 JXF605014Q JXF一6050/20 IP54 1.5 600 500 670 450 565 565 448 2.0 2 JXF605020Q JXF一6050/25 IP54 1.5 600 500 670 450 565 565 448 2.0 2 JXF605025Q JXF一7050/1 6 IP54 1.5 700 500 770 450 665 665 448 2.0 2 JXF705016Q JXF一7050/20 IP54 1.5 700 500 770 450 665 665 448 2.0 2 JXF705020Q JXF一7050/25 IP54 1.5 700 500 770 450 665 665 448 2.0 2 JXF705025Q JXF一8060/20 IP54 1.5 800 600 870 550 765 765 548 2.0 2 JXF806020Q JXF一8060/25 IP54 1.5 800 600 870 550 765 765 548 2.0 2 JXF806025Q JXF一10080/20 IP54 1.5 1000 800 1070 750 965 965 748 2.0 2 JXF1008020Q JXF一10080/25 IP54 1.5 1000 800 1070 750 965 965 748 2.0 2 JXF1008025Q JXF一10080/30 IP54 1.5 1000 800 1070 750 965 965 748 2.0 2 JXF1008030Q
  • 70. 061 Final Distribution Technical Data Unit: mm Overall Dimensions x handle lock hinge door bo sealing rubber gasket sealing rubber gasket wall fixing bracket JXF Metal Enclosure Standard: EN60529 Protection grade Standard: Certificate Rated voltage Rated insulated voltage Rated operating current Withstand current Sheet thickness Mounting plate thickness Hinge Sealing rubber gasket Cable gland Type JXF IP43 Improved IP43 EN60529 CE 220/400V 660V 400A 15kA 1.0~1.5mm 1.0~1.5mm Enhanced Black rubber gasket bottom only IP54 IP54 EN60529 CE 220/400V 660V 400A 15kA 1.2-1.5mm 2.0mm Enhanced Black rubber gasket bottom only
  • 71. 062 Low-voltage Distribution Molded Case Circuit Breaker & Air Circuit Breaker Product Overview 063 086 Current: 16-800A Breaking Capacity: L,S,M,T CDM6S CDM6L Current: 40-630A Breaking Capacity: L,M 103 112 CDM1 CDM1LE Current: 10-1250A Breaking Capacity: L,M Current: 16-400A Breaking Capacity: L,M 120 169 CDW9 CDW6 Current: 630~6300A Voltage: 400/415V, 690V Current: 200~6300A Voltage: 400V Molded Case Circuit Breaker Air Circuit Breaker
  • 72. 063 Low-voltage Distribution Type Pole In A Fixed Thermal Magnetic Thermo-adjustable L-type S-Type M-type T-Type M-type T-Type CDM6s-63 3 10 16 20 25 32 40 50 63 4 10 16 20 25 32 40 50 63 CDM6s-100 3 16 20 25 32 40 50 63 80 100 4 16 25 40 63 100 CDM6s-250 3 100 125 160 180 200 225 250 4 125 160 200 250 Order Information CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 CDM6s063L0103XXXF CDM6s063L0163XXXF CDM6s063L0203XXXF CDM6s063L0253XXXF CDM6s063L0323XXXF CDM6s063L0403XXXF CDM6s063L0503XXXF CDM6s063L0633XXXF - - - - - - - - CDM6s100L0163XXXF CDM6s100L0203XXXF CDM6s100L0253XXXF CDM6s100L0323XXXF CDM6s100L0403XXXF CDM6s100L0503XXXF CDM6s100L0633XXXF CDM6s100L0803XXXF CDM6s100L1003XXXF - - - - - CDM6s250L1003XXXF CDM6s250L1253XXXF CDM6s250L1603XXXF CDM6s250L1803XXXF CDM6s250L2003XXXF CDM6s250L2253XXXF CDM6s250L2503XXXF - - - - CDM6s063S0103XXXF CDM6s063S0163XXXF CDM6s063S0203XXXF CDM6s063S0253XXXF CDM6s063S0323XXXF CDM6s063S0403XXXF CDM6s063S0503XXXF CDM6s063S0633XXXF - - - - - - - - CDM6s100S0163XXXF CDM6s100S0203XXXF CDM6s100S0253XXXF CDM6s100S0323XXXF CDM6s100S0403XXXF CDM6s100S0503XXXF CDM6s100S0633XXXF CDM6s100S0803XXXF CDM6s100S1003XXXF - - - - - CDM6s250S1003XXXF CDM6s250S1253XXXF CDM6s250S1603XXXF CDM6s250S1803XXXF CDM6s250S2003XXXF CDM6s250S2253XXXF CDM6s250S2503XXXF - - - - CDM6s063M0103XXXF CDM6s063M0163XXXF CDM6s063M0203XXXF CDM6s063M0253XXXF CDM6s063M0323XXXF CDM6s063M0403XXXF CDM6s063M0503XXXF CDM6s063M0633XXXF CDM6s063M0104XXXF CDM6s063M0164XXXF CDM6s063M0204XXXF CDM6s063M0254XXXF CDM6s063M0324XXXF CDM6s063M0404XXXF CDM6s063M0504XXXF CDM6s063M0634XXXF - - - - - - - - - - - - - - - - - - - - - - - - - CDM6s063T0103XXXF CDM6s063T0163XXXF CDM6s063T0203XXXF CDM6s063T0253XXXF CDM6s063T0323XXXF CDM6s063T0403XXXF CDM6s063T0503XXXF CDM6s063T0633XXXF CDM6s063T0104XXXF CDM6s063T0164XXXF CDM6s063T0204XXXF CDM6s063T0254XXXF CDM6s063T0324XXXF CDM6s063T0404XXXF CDM6s063T0504XXXF CDM6s063T0634XXXF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CDM6s100M0163XXX3 - CDM6s100M0253XXX3 - CDM6s100M0403XXX3 - CDM6s100M0633XXX3 - CDM6s100M1003XXX3 CDM6s100M0164XXX3 CDM6s100M0254XXX3 CDM6s100M0404XXX3 CDM6s100M0634XXX3 CDM6s100M1004XXX3 - CDM6s250M1253XXX3 CDM6s250M1603XXX3 - CDM6s250M2003XXX3 - CDM6s250M2503XXX3 CDM6s250M1254XXX3 CDM6s250M1604XXX3 CDM6s250M2004XXX3 CDM6s250M2504XXX3 - - - - - - - - - - - - - - - - CDM6s100T0163XXX3 - CDM6s100T0253XXX3 - CDM6s100T0403XXX3 - CDM6s100T0633XXX3 - CDM6s100T1003XXX3 CDM6s100T0164XXX3 CDM6s100T0254XXX3 CDM6s100T0404XXX3 CDM6s100T0634XXX3 CDM6s100T1004XXX3 - CDM6s250T1253XXX3 CDM6s250T1603XXX3 - CDM6s250T2003XXX3 - CDM6s250T2503XXX3 CDM6s250T1254XXX3 CDM6s250T1604XXX3 CDM6s250T2004XXX3 CDM6s250T2504XXX3
  • 73. 064 Low-voltage Distribution Type Pole In A Fixed Thermal Magnetic Thermo-adjustable L-type S-Type M-type T-Type M-type T-Type CDM6s-400 3 200 225 250 315 350 400 4 200 225 250 315 350 400 CDM6s-630 3 400 500 630 4 400 500 630 CDM6s-800 3 400 500 630 700 800 4 400 500 630 700 800 CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 CDM6s400L2003XXXF CDM6s400L2253XXXF CDM6s400L2503XXXF CDM6s400L3153XXXF CDM6s400L3503XXXF CDM6s400L4003XXXF CDM6s400L2004XXXF CDM6s400L2254XXXF CDM6s400L2504XXXF CDM6s400L3154XXXF CDM6s400L3504XXXF CDM6s400L4004XXXF CDM6s630L4003XXXF CDM6s630L5003XXXF CDM6s630L6303XXXF CDM6s630L4004XXXF CDM6s630L5004XXXF CDM6s630L6304XXXF CDM6s800L4003XXXF CDM6s800L5003XXXF CDM6s800L6303XXXF CDM6s800L7003XXXF CDM6s800L8003XXXF CDM6s800L4004XXXF CDM6s800L5004XXXF CDM6s800L6304XXXF CDM6s800L7004XXXF CDM6s800L8004XXXF CDM6s400S2003XXXF CDM6s400S2253XXXF CDM6s400S2503XXXF CDM6s400S3153XXXF CDM6s400S3503XXXF CDM6s400S4003XXXF CDM6s400S2004XXXF CDM6s400S2254XXXF CDM6s400S2504XXXF CDM6s400S3154XXXF CDM6s400S3504XXXF CDM6s400S4004XXXF CDM6s630S4003XXXF CDM6s630S5003XXXF CDM6s630S6303XXXF CDM6s630S4004XXXF CDM6s630S5004XXXF CDM6s630S6304XXXF CDM6s800S4003XXXF CDM6s800S5003XXXF CDM6s800S6303XXXF CDM6s800S7003XXXF CDM6s800S8003XXXF CDM6s800S4004XXXF CDM6s800S5004XXXF CDM6s800S6304XXXF CDM6s800S7004XXXF CDM6s800S8004XXXF - - - - - - - - - - - - - - - - - - CDM6s800M4003XXXF CDM6s800M5003XXXF CDM6s800M6303XXXF CDM6s800M7003XXXF CDM6s800M8003XXXF CDM6s800M4004XXXF CDM6s800M5004XXXF CDM6s800M6304XXXF CDM6s800M7004XXXF CDM6s800M8004XXXF - - - - - - - - - - - - - - - - - - CDM6s800T4003XXXF CDM6s800T5003XXXF CDM6s800T6303XXXF CDM6s800T7003XXXF CDM6s800T8003XXXF CDM6s800T4004XXXF CDM6s800T5004XXXF CDM6s800T6304XXXF CDM6s800T7004XXXF CDM6s800T8004XXXF - - CDM6s400M2503XXX3 - - CDM6s400M4003XXX3 - - CDM6s400M2504XXX3 - - CDM6s400M4004XXX3 - CDM6s630M5003XXX3 CDM6s630M6303XXX3 - CDM6s630M5004XXX3 CDM6s630M6304XXX3 - - - - - - - - - - - - CDM6s400T2503XXX3 - - CDM6s400T4003XXX3 - - CDM6s400T2504XXX3 - - CDM6s400T4004XXX3 - CDM6s630T5003XXX3 CDM6s630T6303XXX3 - CDM6s630T5004XXX3 CDM6s630T6304XXX3 - - - - - - - - - - Order Information
  • 74. 065 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Technical Data Frame Size Number of Poles Breaking Capacity Level 3P L S M T L S 25 18 50 30 35 M T 50 30 4P 3P 4P Rated Ultimate Short-circuit Breaking Capacity Icu (kA rms) Rated Service Short-circuit Breaking Capacity Ics (kA rms) Mechanical Durabilities Electrical Durabilities On-off Cycle shows it has this option; means it has no this option. See Page 74 See Page 75 See Page 76 Basic Information (IEC60947-2) Tripping Unit Accessory OF SD Indication Accessories Control Accessories Connection Spreader Protection Phase Barrier Installation Information Mounting & Connection Rated Current (A) MX(AC400, 230V, DC220V) MN (AC400, 230V) Extended Rotary Handle (Round and Square) AC Motor Mechanism (AC400, 230V) Mechanical Interlock Fixed, Front Connection Fixed, Rear Connection Plug-in, Rear Connection Plug-in, Front Connection Drawer-out, Rear Connection 75% 100% 75% S 26 100% L 35 75% S 26 100% 50% 100% 50% 100% 16/20//25/32/40/ 50/63/80/100 100/125/160/180/ 200/225/250 Fixed Thermal Magnetic 26 3P 4P L 35 75% S 26 100% L 35 75% 100%
  • 75. 066 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Technical Data Frame Size Number of Poles Breaking Capacity Level Rated Ultimate Short-circuit Breaking Capacity Icu (kA rms) Rated Service Short-circuit Breaking Capacity Ics (kA rms) On-off Cycle shows it has this option; means it has no this option. Basic Information (IEC60947-2) Tripping Unit Accessory OF SD Indication Accessories Control Accessories Connection Spreader Protection Phase Barrier Installation Information Mounting & Connection Rated Current (A) MX(AC400, 230V, DC220V) MN (AC400, 230V) Extended Rotary Handle (Round and Square) AC Motor Mechanism (AC400, 230V) Mechanical Interlock Fixed, Front Connection Fixed, Rear Connection Plug-in, Rear Connection Plug-in, Front Connection Drawer-out, Rear Connection See Page 77 See Page 78 See Page 79 Mechanical Durabilities Electrical Durabilities Fixed Thermal Magnetic S L S L 50 30 50 30 3P 4P 50% 200/225/250/315/ 350/400 100% 50% 100% S L S L 50 30 50 30 3P 4P 50% 100% 50% 100% T L S M 50 30 70 40 3P 4P 50% 100% 50% 100% T L S M 50 30 70 40 50% 100% 50% 100%
  • 76. 067 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Technical Data Frame Size Number of Poles Breaking Capacity Level Rated Ultimate Short-circuit Breaking Capacity Icu (kA rms) Rated Service Short-circuit Breaking Capacity Ics (kA rms) Mechanical Endurance Electrical Endurance On-off Cycle shows it has this option; means it has no this option. See Page 75 See Page 77 See Page 78 Basic Information (IEC60947-2) Tripping Unit Accessory OF SD Indication Accessories Control Accessories Connection Spreader Protection Phase Barrier Installation Information Mounting & Connection Rated Current (A) Thermo-adjustable Setting (Ir) MX(AC400, 230V, DC220V) MN (AC400, 230V) Extended Rotary Handle (Round and Square) AC Motor Mechanism (AC400, 230V) Mechanical Interlock Fixed, Front Connection Fixed, Rear Connection Plug-in, Rear Connection Plug-in, Front Connection Drawer-out, Rear Connection Thermo-adjustable 16/25/40/63/100 125/160/200/250 250/400 500/630 See Page 76 T M T M 50 30 50 30 3P 4P 50% 100% 50% 100% T M T M 50 30 50 30 3P 4P 50% 100% 50% 100% T M T M 70 40 70 40 3P 4P 50% 100% 50% 100% T M T M 70 40 70 40 3P 4P 50% 100% 50% 100%
  • 77. 068 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Basic Technical Data Complete Functions and Accessories Rated Insulation Voltage Ui: AC 800V (Frame 63AF: AC 690V) Rated Impulse Withstand Voltage Uimp: 8KV (Frame 63AF: 6KV) Rated Working Voltage Ue: AC 415V (Frame 63AF: AC 400) Rated Working Frequency: 50Hz/60Hz Utilization Category: A Isolation Function: Applicable for all series Spreader Phase Barrier AC Motor Mechanism Round Extended Rotary Handle Square Extended Rotary Handle MX MN Plug-in Connecting Terminal Plug-in Front Connection Drawer-out Rear Connection Plug-in Rear Connection Fixed Rear Connection Mechanical Interlock SD OF
  • 78. 069 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Complete Functions Optional Tipping Unit Functions The tripping unit is the intelligent part of the moulded case circuit breaker. CDM6s Thermal Magnetic Tripping Unit is divided into 2 types, that is, Fixed Rating and Thermal- adjustable Tripping Unit. Fixed Thermal Magnetic Tripping Unit Thermal-adjustable, Fixed-magnetic Tripping Unit Be used for overload and short-circuit protection. Be used for overload and short-circuit protection Adjustable overload current Change the relation between the overload current and the rated current by adjusting the grades of the knobs (0.8-0.9-1.0In, three grades are available to be adjusted). Even so the current of instantaneous protection movement shall still take the rated current as the base number E.g.: The customers need 250AF, 200A current MCCB, and considering the product expansion in the future, it is required to select the circuit breaker with overload adjustable feature. So which kind of the product should the customers choose, how much is it for overload tripping release current (Ir1) and instantaneous tripping release current (Ii)? Answer: CDM6s, 250AF, M-Type Breaking Capacity, Rated Current 250A, and switch the knob in the grade of 0.8. So, Ir1=250A * 0.8=200A, Ii=250 * 10=2500A. CDM6s All Series of Products Featuring Isolation Function ● The circuit breaker with isolation function shall meet the standard of IEC 60947-2. ● The operating handle hasn’t indicated “OFF” position until the contact has been indeed opened. ● The Isolation Function Protection includes: ○ Mechanical reliability of the contact indication system ○ No leakage current ○ Over-voltage Withstand Capacity between outlet and inlet terminals
  • 79. 070 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Accessory Name Accessory Name Complete Accessories of CDM6 Series Indicating Accessories Auxiliary Contact (OF): be connected in the auxiliary circuit of switch device and used for the accessories to indicate the position of the circuit breaker contacts Alarm Switch (SD): be used for the accessories under the state of on and off or trip of the indication circuit breaker for the following 5 reasons: Overload or short-circuit fault Residual earth-leakage fault Artificial Testing Release Shunt Trip Release Line Fault and Under-voltage Release Tripping OF SD Rated Thermal Current (A) Utilization Category Working Current 50Hz/60Hz Tripping Switch-on/off Switch-on/off Electrical Parameter of OF & SD Tripping Control Accessories Under-voltage Release (MN) Tripping threshold between 0.35 and 0.7 times the rated voltage; when it is at 85%-110% of rated working voltage, Under-voltage Release shall ensure the circuit breaker switch-on; when the rated working voltage is less than 35%, Undervoltage Release shall prevent switch-on of the circuit breaker. Applicable Type of Circuit Breaker Power Consumption of Under-voltage Coil (W) Ue Undervoltage Release Wiring
  • 80. 071 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Complete Accessories of CDM6 Series
  • 81. 072 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Complete Accessories of CDM6 Series
  • 82. 073 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Alarm Switch Auxiliary Contact Shunt Release Under-voltage Release Alarm Switch Shunt Release Auxiliary Contact Undervoltage Release Installation Location of Accessories Installation Method for Tripping Release and Accessories Code Lead Direction Handle Installation at Right Side Installation at Left Side Name of Accessory Product Type Auxiliary Contact Shunt Release Shunt Release Undervoltage Release Auxiliary Contact Undervoltage Release Shunt-trip Release Alarm Switch Undervoltage Release Alarm Switch Shunt Release Auxiliary Contact Alarm Switch Auxiliary Contact Undervoltage Release Alarm Switch
  • 83. 074 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 : : M5*14 M5*14 117 25 25 Φ3.5 (3-pole no size) 117 25 3.5 7 25 25 25 25 117 (3-pole no size) (3-pole no size) CDM6s63 Installation Dimension Chart of Fixed Front Connection Installation Hole Chart of Fixed Rear Connection Installation Hole Fixed Rear Connection Wiring Chart of Terminal Connection Installation Hole Plug-in Rear Connection Wiring Chart of Plug-in Rear Connection Installation Hole Installation Dimension of Fixed Front Connection Remark: X-X, Y-Y is the center of 3-pole circuit breaker Remark: X-X, Y-Y is the center of 3-pole circuit breaker L=S/M=T
  • 84. 075 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 7.5 M8*16 129 30 30 Φ4.5 (3-pole no size) 129 30 4.5 12 30 30 30 30 132 (3-pole no size) (3-pole no size) CDM6s100 Installation Dimension Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection Chart of Fixed Rear Connection Installation Hole Fixed Rear Connection Wiring Plug-in Rear Connection Wiring Chart of Terminal Connection Installation Hole Chart of Plug-in Rear Connection Installation Hole Remark: X-X, Y-Y is the center of 3-pole circuit breaker Remark: X-X, Y-Y is the center of 3-pole circuit breaker L=S/M=T
  • 85. 076 Low-voltage Distribution Chart of Terminal Connection Installation Hole M8*16 Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection Fixed Rear Connection Wiring Plug-in Rear Connection Wiring Chart of Fixed Rear Connection Installation Hole Remark: X-X, Y-Y is the center of 3-pole circuit breaker Remark: X-X, Y-Y is the center of 3-pole circuit breaker 126 35 4.5 14 35 35 35 35 144 (3-pole no size) (3-pole no size) 126 35 35 Φ4.5 Chart of Plug-in Rear Connection Installation Hole CDM6s250 Installation Dimension (3-pole no size) L=S/M=T : : CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2
  • 86. 077 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2
  • 87. 078 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 M12*40 CDM6s630 Installation Dimension Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection Chart of Fixed Rear Connection Installation Hole Fixed Rear Connection Wiring Plug-in Rear Connection Wiring Chart of Terminal Connection Installation Hole Remark: X-X, Y-Y is the center of 3-pole circuit breaker Remark: X-X, Y-Y is the center of 3-pole circuit breaker 200 58 58 Φ5.5 200 58 5.5 40 58 58 58 58 234 (3-pole no size) (3-pole no size) Chart of Plug-in Rear Connection Installation Hole (3-pole no size) L=S/M=T
  • 88. 079 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 12 16 M12*40 243 70 70 Φ5.5 243 70 5.5 40 70 70 70 70 243 Chart of Plug-in Rear Connection Installation Hole CDM6s800 Installation Dimension Chart of Fixed Front Connection Installation Hole Installation Dimension of Fixed Front Connection Fixed Rear Connection Wiring Plug-in Rear Connection Wiring Chart of Terminal Connection Installation Hole Remark: X-X, Y-Y is the center of 3-pole circuit breaker Remark: X-X, Y-Y is the center of 3-pole circuit breaker Chart of Fixed Rear Connection Installation Hole (3-pole no size) (3-pole no size) (3-pole no size) L=S/M=T
  • 89. 080 Low-voltage Distribution Plug-in Front Connection Installation Dimension (CDM6s100 and CDM6s250) Drawer-out Rear Connection Base (CDM6s400, CDM6s630 and CDM6s800) Equipped with Circuit Breaker Pole No. Equipped with Circuit Breaker Equipped with Circuit Breaker Pole No. Pole No. Appearance and Installation Dimension (mm) Appearance and Installation Dimension (mm) Appearance Dimension (mm) Installation Dimension CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Wire connection behind board
  • 90. 081 Low-voltage Distribution CDM6s 63A-800A Fixed and Plug-in Circuit Breaker Connection Hole-opening Dimension Safety Distance Length of Exposed Conductor +B Pole No. Type of Circuit Breaker Installation Dimension AC Motor Mechanism Remark: no matter whether the products have the accessories, the distance between the products must meet the requirements of C distance. Type of Circuit Breaker Exposure of Front Cover and Pull-out Handle Exposure of Pull-out Handle Only Type of Circuit Breaker CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Make Trip Break Manual Motor Auto Motor Mechanism
  • 91. 082 Low-voltage Distribution 80 9 4 80 65 65 80 80 Φ65 Φ4.5 Φ42 Φ36 5 3 32 CDM6s63-800 Frame (3P) Mechanical Interlock Dimension CDM6s63-800 Frame Extension Rotary Handle Base Dimension Type of Circuit Breaker Type of Circuit Breaker Breaking Capacity Level Remark: the shortest distance of G connecting rod is 50 mm, and ex-factory standard configuration is 150mm, please contact the factory, if the special customization is required. CDM6s63-800 Frame Extension Rotary Handle Round Square ≥200 compare to hinge ≥200 compare to hinge CDM6s63, CDM6s100 and CDM6s250 is 65 or 95 for option, the default value is 65. CDM6s400, CDM6s630 and CDM6s800 is 95 or 125 for option, the default value is 95. L,S M,T L,S M,T L,S M,T L/S/M/T L/S/M/T L/S/M/T CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 G
  • 92. 083 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 40°C 30°C 20°C When environmental temperature is over 40°C, small changes have taken place on overload protection properties. In tripping release time /current curve, the Ir setting value of the circuit breaker must be corrected as per the following factors. There is no impact on the performance of the circuit breaker when the height is below 2000m. But when it is over 2000m, the falling factors as air insulation properties and cooling capability shall be considered; the correction factors given in the table below are applicable for the conditions of the height for the installation over 2000m, the breaking capacity of the circuit breaker remains unchanged. Altitude (m) Max.Working Voltage (V) 30°C Thermal Rated Value (A) Average Isolation Voltage (V) Dielectric Strength (V) 55 50 45 40 0.94 0.95 0.95 0.94 0.93 0.88 1 1 1 1 1 1 CDM6s 63 CDM6s 100 CDM6s 250 CDM6s 400 CDM6s 630 CDM6s 800 0.88 0.89 0.91 0.87 0.88 0.83 0.80 0.84 0.87 0.81 0.83 0.79 0.72 0.76 0.82 0.73 0.76 0.76 60 Type of Circuit Breaker Power-up Current Front Connection Wiring (Standard) Rear Connection Wiring Plug-in Wiring Impact of High Temperature on Tipping Release Performance Impact of Altitude on Tipping Release Performance 3-Pole (W) Total Power Loss Type of Circuit Breaker Ambient Temperature °C
  • 93. 084 Low-voltage Distribution CDM6s100 63A-100A, the black line is used for the distribution. CDM6s250 100A-250A, the black line is used for the distribution. Instantaneous current range: 10In ± 20% CDM6s63 10A-63A, the black line is used for the distribution. CDM6s100 16A-50A, the black line is used for the distribution. Instantaneous current range: 10In ± 20% Instantaneous current range: 10In ± 20% Instantaneous current range: 10In ± 20% Tripping Release Curve CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2
  • 94. 085 Low-voltage Distribution CDM6s Molded Case Circuit Breaker Standard: IEC 60947-2 Tripping Release Curve CDM6s800 700A-800A is used for the power distribution. .5 .7 1 2 3 4 5 7 10 20 30 50 70100 200 300 5 000 2 000 1 000 500 100 200 50 20 10 5 2 1 .5 .2 .1 .05 .02 .01 .005 .002 .001 I/Ir I/Ir Instantaneous current range: 10In ± 20% CDM6s400 200A-400A, the black line is used for the power distribution. CDM6s630 400A-630A is used for the power distribution. CDM6s800 400A-630A is used for the power distribution. Instantaneous current range: 10In ± 20% Instantaneous current range: 10In ± 20% .5 .7 1 2 3 4 5 7 10 20 30 50 70100 200 300 5 000 2 000 1 000 500 100 200 50 20 10 5 2 1 .5 .2 .1 .05 .02 .01 .005 .002 .001 Instantaneous current range: 6In ± 20%
  • 95. 086 Low-voltage Distribution Type Pole In A L-type M-type CDM6L-100 3 40 CDM6L100L403XX*F CDM6L100M403XX*F 50 CDM6L100L503XX*F CDM6L100M503XX*F 63 CDM6L100L633XX*F CDM6L100M633XX*F 80 CDM6L100L803XX*F CDM6L100M803XX*F 100 CDM6L100Ll003XX*F CDM6L100M1003XX*F 4 40 CDM6L100L404XX*F CDM6L100M404XX*F 50 CDM6L100L504XX*F CDM6L100M504XX*F 63 CDM6L100L634XX*F CDM6L100M634XX*F 80 CDM6L100L804XX*F CDM6L100M804XX*F 100 CDM6L100Ll004XX*F CDM6L100M1004XX*F CDM6L-250 3 100 CDM6L250L1003XX*F CDM6L250M1003XX*F 125 CDM6L250L1253XX*F CDM6L250M1253XX*F 160 CDM6L250L1603XX*F CDM6L250M1603XX*F 180 CDM6L250L1803XX*F CDM6L250M1803XX*F 200 CDM6L250L2003XX*F CDM6L250M2003XX*F 225 CDM6L250L2253XX*F CDM6L250M2253XX*F 250 CDM6L250L2503XX*F CDM6L250M2503XX*F 4 100 CDM6L250L1004XX*F CDM6L250M1004XX*F 125 CDM6L250L1254XX*F CDM6L250M1254XX*F 160 CDM6L250L1604XX*F CDM6L250M1604XX*F 180 CDM6L250L1804XX*F CDM6L250M1804XX*F 200 CDM6L250L2004XX*F CDM6L250M2004XX*F 225 CDM6L250L2254XX*F CDM6L250M2254XX*F 250 CDM6L250L2504XX*F CDM6L250M2504XX*F CDM6L-400 3 200 CDM6L400L2003XX*F CDM6L400M2003XX*F 225 CDM6L400L2253XX*F CDM6L400M2253XX*F 250 CDM6L400L2503XX*F CDM6L400M2503XX*F 315 CDM6L400L3153XX*F CDM6L400M3153XX*F 350 CDM6L400L3503XX*F CDM6L400M3503XX*F 400 CDM6L400L4003XX*F CDM6L400M4003XX*F 4 200 CDM6L400L2004XX*F CDM6L400M2004XX*F 225 CDM6L400L2254XX*F CDM6L400M2254XX*F 250 CDM6L400L2504XX*F CDM6L400M2504XX*F 315 CDM6L400L3154XX*F CDM6L400M3154XX*F 350 CDM6L400L3504XX*F CDM6L400M3504XX*F 400 CDM6L400L4004XX*F CDM6L400M4004XX*F CDM6L-630 3 400 CDM6L630L4003XX*F CDM6L630M4003XX*F 500 CDM6L630L5003XX*F CDM6L630M5003XX*F 630 CDM6L630L6303XX*F CDM6L630M6303XX*F 4 400 CDM6L630L4004XX*F CDM6L630M4004XX*F 500 CDM6L630L5004XX*F CDM6L630M5004XX*F 360 CDM6L630L6304XX*F CDM6L630M6304XX*F name Frame size B.C Rate Current Pole Accessory Voltage of Accessory Residual current Installation method CDM6L 100 L 100 3P M 1 F R ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 100:100AF L:L type 40,50, 63,80,100 3:3P X:No Accessory X:AC400V;NO Accessory voltage; Leakage module voltage AC400V Y:30/100/500mA (100AF, 250AF) F:fix-type in front of the board 250:250AF M:M type 100.125. 160.180.200. 225.250 A:4P A Type N phase is not equipped with overcurrent trip component and N phase is always connected. The N phase does not open/close with the other 3 poles. M:MX N:AC230V;intenal accessory AC230V; Leakage module AC230V T:100/300/500mA (100AF, 250AF, 400AF, 630AF) R:fix-type behind the board 400:400AF 200.225. 250.315. 350.400 B: 4P B Type N phase is not equipped with overcurrent trip component, and N phase opens/closes with the other 3 poles. (N phase closes first and then opens) O:OF D:DC24V F:300/500/1000mA (400AF, 630AF) P:insert-type behind the board 630:630AF 400.500.630 C: 4P C Type N phase is equipped with overcurrent trip component, and N phase always opens/closes with the other 3 poles . (N phase closes first and then opens) N:MN 1:Internal accessory AC400V; Leakage module AC230V D: 4P D Type N phase is equipped with overcurrent trip component and N phase is always connected. The N phase does not open/close with the other 3 poles F:OF+OF 2: Internal accessory AC230V;Leakage module AC400V S:SD 3:Internal accessory DC24V;Leakage module AC400V D:OF+S 4:Internal accessory DC24V;Leakage module AC230V U:Leakage alarm without action module I:Leakage alarm with action module A:MX+Leakage alarm without action module 1:MX+Leakage alarm with action module B:OF+Leakage alarm without action module 2:OF+Leakage alarm with action module C:MN+Leakage alarm without action module 3:MN+Leakage alarm with action module E:OF+OF+Leakage alarm without action module 4:OF+OF+Leakage alarm with action module G:SD+Leakage alarm without action module 5:SD+Leakage alarm with action module H:OF+SD+Leakage alarm without action module 6:OF+SD+Leakage alarm with action module Note:* express residual current Coding System Order Information CDM6L Earth-Leakage Circuit Breaker Standard: IEC 60947-2
  • 96. 087 Low-voltage Distribution Thermo-adjustable Basic Information(IEC60947-2) Rated Ultimate Short—circuit Breaking Capacity Icu(kA rms) Rated Service Short-circuit Breaking Capacity Ics(kA rms) Mechanical Endurance ElectricaI Endurance On-0ff Cycle 100 250 400 630 3P 4P 3P 4P 3P 4P 3P 4P L M L M L M L M L M L M L M L M 35 50 35 50 35 50 35 50 50 70 50 70 50 70 50 70 22 30 22 30 22 30 22 30 30 40 30 40 30 40 30 40 8500 7000 4000 4000 1500 1000 1000 1000 Tripping Unit Rated Current(A) In 40/50/63/80/100 100/125/160/180/ 200/225/250 200/225/250/315/ 350/400 400/500/630 Accessory Indication Accessories OF ■ ■ ■ ■ SD ■ ■ ■ ■ Control Accessories MX(AC400,230V,DC220V) ■ ■ ■ ■ MN(AC400,230V) ■ ■ ■ ■ Extended Rotary Handle(Round and Square) ■ ■ ■ ■ AC Motor Mechanism(AC400,230V) ■ ■ ■ ■ Mounting&Connection Fixed,Rear Connection ■ ■ ■ ■ Plug-in,Rear Connection ■ ■ ■ ■ Connection Spreader ■ ■ ■ ■ Protection Phase Barrier ■ ■ ■ ■ Installation Information See Page 94 See Page 95 See Page 96 See Page 97 "■" shows it has this option Frame Size AF Number of Poles Breaking Capacity Level Technical Date CDM6L Earth-Leakage Circuit Breaker Standard: IEC 60947-2
  • 97. 088 Low-voltage Distribution CDM6L Earth-Leakage Circuit Breaker Standard: IEC 60947-2 ● Rated Insulation Voltage Ui,AC 800V ● Rated Impulse Withstand Voltage Uimp,8KV ● Rated Working Voltage Ue,AC 400V ● Rated Operational Frequency,50Hz ● Utilization Category,A Basic Technical Data 1 Spreader 6 MX 11 SD 2 Phase Barrier 7 MN 12 OF 3 AC Motor Mechanism 8 Leakage Module (Can't order separately) 4 Round Exended Rotary Handle 9 Plug-in Rear Connection 5 Square Exended Rotary Handle 10 Fixed Rear Connection Complete Functions and Accessories
  • 98. 089 Low-voltage Distribution CDM6L Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Trip unit function Except the basic features of overload and short circuit protection, the CDM6L residual current protecting circuit breaker can also provide indirect contact protection for people and prevent fire accident due to damaged insulation and defective grounding current. The circuit breaker can also add functions if needed,including electricity leakage alarm. Versatile functions The circuit breaker conforms to the latest national standards, and uses reliable 3-phase power supply technology. If one phase is missing, i.e. there is one phase loss, the circuit breaker can still provide reliable leakage protection.The product has wide range of voltage input. When the voltage drops to 85V due to power supply failure, the circuit breaker can still provide reliable leakage protection. The time delay function includes non-delay mode and 3-section delay mode, which can be chosen by the user according to residual current. Easy operation The testing button is easy and convenient to use. The micro-switch has sensitive contact and long service life. The trip coil has excellent material and performance with remarkable trip indicating button, which provides a safe and reliable operation environment for clients. Basic parameter information The 4-pole products with N phase are divided to four types. A type: N phase is not equipped with overcurrent trip component and N phase is always connected. The N phase does not open/close with the other 3 poles B type: N phase is not equipped with overcurrent trip component, and N phase opens/closes with the other 3 poles (N phase closes first and then opens) C type: N phase is equipped with overcurrent trip component, and N phase always opens/closes with the other 3 poles (N phase closes first and then opens) D type: N phase is equipped with overcurrent trip component and N phase is always connected. The N phase does not open/close with the other 3 poles. Electric motor protection CDM6L residual current protection circuit breaker with plastic case can be used for electricity distribution protection, frame current under 400 and electric motor protection. Isolation function CDM6L series product has isolation protection function.The operation handle can indicate "OFF" position only when the contact is really opened.
  • 99. 090 Low-voltage Distribution CDM6L Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Complete Accessories of CDM6L Series Indicating Accessories ● Auxiliary Contact(OF): Be connected in the auxiliary circuit of switch device and used for the accessories to indicate the position of the circuit breaker contacts ● Alarm Switch(SD): Be used for the accessories under the state of on and off or trip of the indication circuit breaker for the following reasons: ○ Overload or short-circuit fault ○ Residual ea rth-leakage fault ○ Artificial Testing Release ○ Shunt Trip Release ○ Line Fault and Under-voltage Release Tripping Control Accessories ● Under-voltage Release(MN) Tripping threshold between 0.35 and 0.7 times the rated voltage;when it is at 85%-110%of rated working voltage,Under-voltage Release shall ensure re the circuit breaker switch- on;when the rated working voltage is less than 35,Under voltage Release shall prevent switch-on of the Circuit breaker Accessory Name Switch-on/off Tripping OF Accessory Name Switch-on/off Tripping SD Electrical Parameter of OF&SD Rated Thermal Current(A) Utilization Category Working Current 50Hz AC400V DC220V 3A AC15 DC13 0.3A - - 0.15A Applicable Type of Circuit Breaker Power Consumption of Under—voltage Coil(W) AC400V AC230V CDM6L100 3.9 3.2 CDM6L250 4.3 3.3 CDM6L400 3.6 2.5 CDM6L630 2 1.6
  • 100. 091 Low-voltage Distribution CDM6L Earth-Leakage Circuit Breaker Standard: IEC 60947-2 Complete Accessories of CDM6L Series ● Shunt Release(MX) When the working voltage is between 70%-110%Us ,the shunt release shall reliably trip the circuit breaker. When the rated control supply voltage of the shunt release is DC24V the maximum length of the copper conductor shall satisfy the following requirements: When the requirements above cannot be satisfied,it is recommended to adopt the following chart to design control loop of the shunt release. ● Extended Rotary Handle ○ Function:indication of the three positions of switch—on,switch—off and trip ○ The circuit breaker cannot be switch—on when the switch board door is open ○ The door cannot be opened if the circuit breaker is ON ○ An extension shaft that can be adjusted to the distance between the back of circuit breaker and door the specific distance refers to the dimensions at the rear and the installation part. ○ The OFF—Position of the circuit breaker can han9 1—3 locks with the diameter of 5 mm Applicable Type of Circuit Breaker Power Consumption of Under—voltage Coil(W) AC400V AC230V DC24V CDM6L100 96.8 73 91.2 CDM6L250 112 68.6 85.3 CDM6L400 67 62.3 100 CDM6L630 163 153 120 1.5mm² 2.5mm² 100%Us 85%Us 150m 100m 250m 160m Conductor Area Rated Control Supply Voltage(DC24V) Shunt release AC50Hz 230V, 400V;