The Synaptix II cabinet is designed to mount hardware solutions from multiple manufacturers and intelligently connect them to power, networks, and management
solutions. These features are integrated into the design assuring “built in” cable management.
How to Troubleshoot Apps for the Modern Connected Worker
Customizable High Density Data Center Enclosures
1. NetIG-SynaptixDS1 4/30/09 3:14 PM Page 1
SYNAPTIX
server & storage enclosures
The Synaptix II cabinet is designed to allows for maximum airflow. Access to the
mount hardware solutions from multiple vertical patch panels, power distribution
manufacturers and intelligently connect units, and computer hardware is unob-
them to power, networks, and manage- structed due to the offset VMA system and
ment solutions. These features are inte- the extra depth of our cabinet.
grated into the design assuring “built in”
cable management. In addition, having 3 extra Rack Mounting
Spaces and two multimedia cable cutouts
Our strong, fully-welded frame and wide in the VMAs turns a 44u cabinet into a 47u
selection of accessories and cooling cabinet without increasing the width or
options makes for the ideal cabinet in any even more importantly, without adding
data center. It is available in different extra cost.
dimensions and can be customized to
meet your exacting requirements. Incorporating other design concepts such
as zero clearance two piece removable
The Synaptix cabinet’s offset Vertical side panels, multiple cable egress points,
Mounting Angle (VMA) system delivers 180 degree door hinges and the ability to Synaptix II offers the perfect balance of form and
function. Utilizing a fully perforated front door with
ease of hardware installation by ensuring control air flow, as well as proactively low profile handle, Synaptix II offers an aesthetically
that power and network cables are extract heat addresses the data center pleasing, functional enclosure while exceeding third
party open air ventilation requirements of equipment
installed with one length on the horizon- manager’s challenges in today’s dynamic manufacturers.
tal plane. Minimizing vertical routing of computing environments.
patch cords reduces cabling clutter
KEY FEATURES:
• Multi-vendor platform supports Dell, HP, IBM, Cisco
and most other equipment manufacturers
• Rugged 2000lbs weight capacity
• UBC Zone 4 Compliant
• 180 degree door hinges
• True 24" wide footprint eliminates floor creep
• Heavy duty 12 guage 0.375 square hole mounting angles
are fully adjustable front to rear
• Zero footprint 2-piece flush side panel construction Split rear doors, utilizing 180 degree hinges, allow
• Optimized for use with all NetIG connectivity products unobstructed access to equipment reducing aisle
blockage without removing the doors.
21249 72nd Avenue South, Kent,WA 98032 t: 425.291.4200 www.net-ig.com
2. NetIG-SynaptixDS1 4/30/09 3:14 PM Page 2
SYNAPTIX
server & storage enclosures
DESIGN FEATURES Specifications/Ordering Information
Frame Assemblies -42U (73.5” Panel Space) - 2Cool Ready
SMART OFFSET MOUNTING ANGLES WITH RACK UNIT IDEN- Maximum Overall Overall Overall Perforated TFT Door
TIFICATION MARKINGS -offset design provides ample space Part Number Rail Spacing Height Width Depth Top Panel Slot
125902-01A 30.32” 80.50” 24.00” 42.00” YES YES
on one side of the rack for power, cabling, vertical patch pan- 125902-02A 30.32” 80.50” 24.00” 42.00” YES NO
els and Centerline. Also, the front angle allows additional 19” 1U 125901-01A 36.32” 80.50” 24.00” 48.00” YES YES
equipment to be mounted vertically. Rack Unit markings include 125901-02A 36.32” 80.50” 24.00” 48.00” YES NO
simplifying alignment during equipment installation and aid in Frame Assemblies -44U (77.0” Panel Space) - 2Cool Ready
Maximum Overall Overall Overall Perforated TFT Door
locating, logging and tracking equipment within an enclosure. Part Number Rail Spacing Height Width Depth Top Panel Slot
125825-01A 36.32” 84.00” 24.00” 48.00” YES YES
VERTICAL PATCH PANEL & INTEGRATED POWER - The rear 125825-02A 36.32” 84.00” 24.00” 48.00” YES NO
125825-03A 36.32” 84.00” 24.00” 48.00” NO YES
channel accommodates up to four 1.75” wide vertical Power Dis- 125825-04A 36.32” 84.00” 24.00” 48.00” NO NO
tribution Units (PDUs) and a Centerline column. We have brack- Frame Assemblies -47U (82.25” Panel Space) - 2Cool Ready
ets to accommodate most major manufacturer’s PDUs. Cou- Maximum Overall Overall Overall Perforated TFT Door
pled with the “built in” vertical rack mounting spaces we allow Part Number Rail Spacing Height Width Depth Top Panel Slot
125900-01A 36.32” 89.00” 24.00” 48.00” YES YES
for all cables to horizontally connected. 125900-02A 36.32” 89.00” 24.00” 48.00” YES NO
125900-03A 36.32” 89.00” 24.00” 48.00” NO YES
125900-04A 36.32” 89.00” 24.00” 48.00” NO NO
2Cool Air Extraction Unit Kit -mounts directly to the top of the Frame Assemblies include:
-heavy duty, fully welded frame - split rear perf doors with 3 point lock - side panels ordered separately
Synaptix frame and includes variable speed fans. Fan speeds are -2 pair 0.375 square hole mounting angles - perforated top panel option - color is black
-full perf front door with lock (with or without - rack-unit identification labels out TFT slot) - casters and levelers
adjusted based on user defined temperature thresholds to main-
tain temperature within the cabinet. Fans are 10” dia. (-48VDC) Side Panels Hardware
Part Number Frame Size Type Part Number Description
producing 600-800CFM ea. Kit also includes solid top panel. Sol- 125902-430A 42Ux42” 2-Piece Flush S1B-1032-50 [50] #10-32X5/8” Screws
id rear doors and side panels with gasketing required for prop- 125901-430A 42Ux48” 2-Piece Flush CN12-1032-50 [50] #10-32X5/8” Cage Nuts
125825-430A 44Ux48” 2-Piece Flush CN-TOOL Cage Nut Installation Tool
er airflow.
125900-430A 47Ux48” 2-Piece Flush
-each part number covers 1 side of frame
-side panels are locking
FRONT DOOR ADJUSTABLE TFT DRAWER SLOT - Optional -ship installed when ordered with cabinet
adjustable slot in door provides user access to a TFT or LCD 2Cool Air Extraction Unit Kits
Part Number Height Kit includes fan hood assembly, solid top panel & interior baffles. 2Cool Air Extraction Kits
screen display drawer without opening the door. Great for local requireFrame Size 125902-900A gasketed solid split rear door kits to ensure proper 42U x
125902-900A 42Ux42” 42” 125901-900A airflow. Order Part Number 125901-500A (42U), 42U x 48” 125825-
maintenance preventing unauthorized access to hardware which 125901-900A 42Ux48” 900A 125825-500A (44U) or 125900-500A (47U) separately.
can cause accidental service disruption. 125825-900A 44Ux48”
125900-900A 47Ux48”
Tooless Filler Panels
SELF-CONTAINED LIFT-OFF HINGES -eliminate loose pins 125606-25A includes:
Part Number Height (3)- 1U panels
which are often lost and speeds removal and replacement of 125606-1A 1U (1.75”) x 19” (3) - 2U panels
125606-25A 25U Panel Kit x 19” (2) - 4U panels
doors on enclosure. The unique, secure design only allows (1)- 8U panel
Painted Black Finish
removal of the door from the enclosure when the door is open, Shelves - 19” Rack-mount
preventing unwanted access. Mounting Usable Required Mtg
Part Number Style Depth Angle Spacing Load Rating
FS1V-1924-2 19” Fixed 24” 24” to 34” 200 lbs.
SPLIT REAR DOOR W/180 DEGREE SWING - provides full SS2V-1924-2 19” Sliding 24” 24” to 34” 100 lbs.
SS3V-1924-2 19” Sliding 30” 28” to 34” 300 lbs.
access to interior of enclosure without removing the door, sim- All shelves are 4 post mounted and painted black. Sliding shelf shown.
plifying and expediting equipment loading and maintenance Lacing Bars - 3.5”W Uni-Strut Lacing Bars
while reducing aisle blockage. Doors include 3-point latching Part Number Height Part Number Height
125901-91A 42U (73.50”) 125901-425A 42U (73.50”)
with swing handle and mechanical key lock. 125825-91A 44U (77.00”) 125825-425A 44U (77.00”)
125900-91A 47U (82.25”) 125900-425A 47U (82.25”)
Vertical Lacing Bars are black w/slots & holes. Vertical Lacing Bars are black w/slots & holes.
21249 72nd Avenue South, Kent,WA 98032 t: 425.291.4200 www.net-ig.com