2. Technical Overview
Optional standards –
translated into practical
examples
Things to look out for – how to
avoid clashes with building
control
Implications for developers
3. Methodology:
Planning Department gets approval from planning inspectorate to
include optional requirements in the local plan;
Planning make Building Regulations optional requirements part of
their conditions for permission;
The duty is for the developer to inform their Building Control body
that optional requirements apply to the submission;
Building Control check and inspect the dwelling in accordance with
the optional requirements;
Any enforcement of the requirements falls to Building Control and
not with planning.
The Optional Requirements
5. Nationally Described Space Standards
Sets out requirements for the Gross Internal (floor) Area of new dwellings at a
defined occupancy as well as floor areas and dimensions for key parts of the
home, notably bedrooms, storage and floor to ceiling height (2.3m for 75% of
the dwelling)
6. Single bed 7.5m2
& 2.15m w
One double bed min
11.5m2
& width 2.75m
others 2.55m
min floor to ceiling height main living
space is 2.3m for at least 75% of the
Gross Internal Area
Gross floor area for
1b = 39m2
6b=138m2
Space Standards – what does this all mean?
8. Regulation 36 amended to introduce a new
optional requirement
•Estimated water use to be no more than 110
litres per person per day (instead of the
normal125 litres per person per day) where a
planning authority makes it a condition of
planning approval (in line with a policy in the
Local Plan) - A policy could apply across a
local authority area or just in part
•Only applies where required by a planning
permission and it then becomes a building
regulation matter
•It is the responsibility of the person carrying
out the work to inform the BCB if the optional
requirement applies
Part G – Water Efficiency -1st
October 2015
9.
10. Part G – Water Efficiency
Regulation G2 has been amended to allow for the
requirements to be met using a “fittings-based
approach”
•This allows compliance to be demonstrated without
completing the Water Calculator
•Compliance demonstrated if all fittings at least as
efficient as specified in new Tables 2.1 and 2.2
•Where fittings approach used the notice to the BCB
should state so
•Consequential changes to the Water Calculator
have been made -this is now in a new Appendix A
rather than a stand alone document
11. The choice is yours: fittings approach or water
calculator
OR
12. Part M - now 2 volumes – 1st
October 2015
Removed reference M4
(dwellings) in Volume 2
13. Part M Volume 1 - Dwellings
•New Regulation M4 applies to dwellings only – and is in three parts;
M4(1) – Category 1 Visitable Dwellings (as existing)
M4(2) – Category 2, Accessible and adaptable dwellings
M4(3) – Category 3, Wheelchair user dwellings
Now applies to new dwellings and material alterations but not an extension
to a dwelling. Does not apply to Change of Use (Regulation 5).
Part M – Access to and use of buildings
14. Applies to all new build dwellings…
Now applies to new dwellings and material alterations but not an
extension to a dwelling. Does not apply to Change of Use (Regulation
5).
15. Part M Volume 1 – Dwellings
M4(1) - Category 1 Visitable dwellings
Key points
•Provision for people to approach dwelling, including wheelchair users, step free where
possible.
•Able to access dwelling from most likely point of alighting from a car
•Able to enter the dwelling
•Able to access habitable rooms at entrance storey (or principal storey if entrance storey
contains no habitable rooms)
•Able to access a WC at entrance storey (or principal storey if entrance storey contains
no habitable rooms)
•A disabled person who can walk can access any dwelling in a building containing
dwellings
17. Part M Volume 1 – Dwellings
M4(2) – Category 2 Accessible & Adaptable Dwellings
Key points
•Step free access to dwelling, car park space and any communal areas (e.g.
waste storage).
•Step free access to WC and any other accommodation within entrance storey
•Step free access to private outdoor space connected directly to entrance storey
•A wider range of people including the elderly, disabled people and some
wheelchair users can use the accommodation and its facilities
•Able to be adapted in the future
18. M4(2) – Accessible and Adaptable Dwellings - Approach
to the dwelling
Access routes must be step free, regardless of storey dwelling is on or
gradient of site.
Where a communal ramp is used that is more than 300mm high there must
also be a stepped approach.
Max gradient 1:12, min width 900mm (private), 1200mm (communal).
19. M4(2) Accessible and Adaptable Dwellings - Car parking
Where parking is provided…
Private in curtilage :
1 standard space (2.4 x 4.8m) that can be widened to 3.3m (not a garage or car port)
Communal to blocks of flats:
1 standard space close to communal
entrance
900mm access zone to side, and
Dropped kerbs min 1m wide, max 1:12
Parking drop off, where provided
Close to communal entrance
Level or gently undulating
Suitable firm ground surface
21. M4(2) Accessible and Adaptable Dwellings - Communal
entrances
• 1500 x 1500mm level
landing.
• Landing is covered to
1200 x 900mm.
• Accessible threshold
(flood risk?)
22. M4(2) Accessible and Adaptable Dwellings - Communal
entrances
If M4(2) 0r M4(3) dwellings are
above ground floor then a
passenger lift must be provided
23. M4(2) Accessible and Adaptable Dwellings – Principal
Private Entrances (or Alternative Private Entrances)
1200 x 1200mm external landing.
Landing covered min 900 x 600mm.
Accessible threshold.
Porch or lobby minimum 1500m
between doors and door swings.
All external private spaces to be served
by a door meeting provisions for width,
threshold, reveal and leading edges.
24. M4(2) Accessible and Adaptable Dwellings – Internal
circulation and layout
Corridors and doors to be wider, leading edge requirements to doors
apply.
Access to all rooms within the entrance storey is step-free.
Entrance storey must contain a living area (living / dining room) with a
window max 850mm above floor level
25. M4(2) Accessible and Adaptable
Dwellings – Bedrooms
Applies to all bedrooms – different access routes depending on bedroom
type
Designer must demonstrate compliance through furniture layout
26. M4(2) Accessible and Adaptable Dwellings – Entrance
Level Sanitary Facilities
Every dwelling: Entrance storey W.C. and basin.
Dwelling of 2-3 storeys, 1-2 bedrooms, W.C. complies with M4(1)
Dwelling of 2-3 storeys, 3 or more beds, the W.C. also requires a level
access shower or ‘potential level access shower’ unless there is an
accessible bathroom on the same storey.
27. M4(2) Accessible and Adaptable Dwellings - Bathroom
provision
An accessible bathroom must be provided on the same storey as the
principal bedroom.
Choose either a standard design or use the design guide to create
bespoke layout.
28. Part M Volume 1 – Dwellings
M4(3) – Category 3 Wheelchair user Dwellings
Key points:
Within curtilage of dwelling (or building containing the dwelling) a step free approach to:
•The dwelling
•Every private entrance door, any private outdoor space, car parking space, and any
communal facility for occupants use
•Internal WC at entrance storey
•Other accom. at entrance storey
•The dwelling is to be adaptable for future wheelchair access
•Services are accessible by people with reduced reach
29. Two types of wheelchair user dwelling;
•Wheelchair Adaptable Regulations 4(3)a - applies as default unless local authority has
policy requiring dwellings to be;
•Wheelchair Accessible ( Regulation 4(3)b).
•Wheelchair adaptable properties have much greater flexibility in their internal layout (e.g
access zones) – they are only intended to be capable of becoming wheelchair accessible
after completion.
•Wheelchair accessible requirement likely to meet most common wheelchair user needs.
•Certain provisions require that ability to be accessible is demonstrated
It is the legal duty of the person undertaking building work to inform Building Control
which requirements applies.
Key Points
M4(3) Category 3 - Wheelchair user dwellings
31. Same principals/requirements as M4(2) with the following extra
provisions:
Route 1200mm min width
More restrictions on position and length of localised restrictions
Level spaces 1500 x 1500mm at maximum 10m intervals and at both
ends
Maximum gradient 1:15
Where complimentary steps provided, single steps to be avoided
Car parking (where provided) min 2.4 x 4.8m an access zone 1200mm
to one side and rear – INCLUDES garages and car ports
M4(3) – Wheelchair Adaptable Dwellings - Approach to the
dwelling
32. M4(3) Wheelchair Adaptable Dwellings - Car parking
Where parking provided:
Private in curtilage - Where it
has a space an access zone
1200mm to one side and rear
Includes garages and car
ports
Communal - a space with
1200mm clear zone both
sides
The side access zones can
be shared between spaces
Clear headroom of 2.2m
33. M4(3) Wheelchair Adaptable Dwellings – Entrances and
external doors
Communal entrances
similar to private.
Both require 1500mm
internal turning circle.
Both require 1200 x
1200mm canopy.
34. Key Points
M4(3) Category 3 – Other External Doors
Requirements for private doors giving
access to a private garden, balcony,
terrace, garage, car port,
conservatory or storage area.
Doors must comply with some of the
principal entrance door requirements
- level threshold, minimum width,
access to edges.
Requirements for leading and
following edges, level thresholds and
maximum reveals remain.
35. Key Points
M4(3) Category 3 – Internal circulation and storage
• Corridors 1050mm min, internal doors
min 850mm.
• Restrictions on door positions near
corners, turning circle required if
outward opening door less than
800mm from corner
• 300mm nibs to leading edge and
200mm to following edge
• 1100mm x 1700mm space in entrance
storey for wheelchair storage with
power socket and1200mm accessible
space required to the front.
• Additional requirement for general
storage areas, with minimum 900mm
headroom
36. M4(3) Wheelchair Adaptable Dwellings – Circulation and
living spaces
Staircase as category 2 but requires stair
lift power socket
Additional provision to be made for future
provision of a through floor lift:
i) Liftway provision is 1100mm wide x 1650mm
long and linking all floors
ii) Drawings demonstrate how liftway provided
without structural alteration or affecting
compliance with any other requirement
Minimum size requirements
for entrance storey living areas
Drawings demonstrate how
kitchen can be adapted to
M4(3b) standard
Minimum worktop length
37. M4(3) Wheelchair Adaptable Dwellings - Bedrooms
One bedroom close to an accessible bathroom.
Every bedroom to have clear access routes.
Principal double bedroom:
i) On entrance storey or adjacent storey;
ii) Minimum 3m wide, minimum 13.5m2; and
iii) 1m wide access to each side and foot of bed (clear of furniture) and 1200 x
1200mm manoeuvring space on either side of the bed.
Every other double or twin bedroom minimum 12.5m2 and 3m wide, 1m clear
access to one side of bed
Every single bedroom 8.5m2 and 2.4m wide.
39. M4(3) Wheelchair Adaptable Dwellings - Sanitary provision
W.C. facilities on the entrance storey, either:
i) A wet room with tanking and floor gulley (which may be a bathroom)
containing a W.C., basin and level access shower; or
ii) Where the dwelling has a bathroom and W.C. on the same storey the
W.C. is reduced provision (dia 3.14).
40. M4(3) Wheelchair Adaptable Dwellings - bathroom
provision
Dwellings up to 4 bedspaces:
bathroom on same level as
principal bedroom with W.C.,
basin, and a level access shower
with ability to have bath installed
above it (unless bath installed
elsewhere on same storey).
Dwellings of 5 or more
bedspaces: a bathroom and a
shower room, either of which may
be an en-suite.
Drawings should indicate how the
bathroom can be adapted to
wheelchair accessible.
41. M4(3) Wheelchair Adaptable Dwellings - private outdoor
space
Definition: gardens, balconies, roof
terraces
Paved areas have suitable surfaces
Minimum width of outdoor spaces is
1500mm
1500mm level turning circle free of door
swing and at ends of path
A level or gently sloping path to every
private store, refuse or recycling
42. Wheelchair Accessible Dwellings
M4(3) Category 3(b) Key Differences
The differences apply only to internal features, not access or communal
routes
Wheelchair accessible lift installed with 1500mm turning circle at every
level and power operated door
Many more controls over services, including type of sanitary fittings and
accessibility of additional controls
Key differences to kitchen and bathroom design
43. Wheelchair Accessible Dwellings
M4(3) Category 3(b) Kitchens
A continuous section of worktop
includes sink, drainer and hob
Worktop is either height
adjustable or re-fixable
Water supply flexible, drainage
flexible or adaptable
Clear leg space underneath up
to 700mm above floor level, no
fixed white goods
Space for an installed oven
centred at 800-900mm above
floor level
At least 400mm of worktop to
one side of ovens and fridges
44. Wheelchair Accessible Dwellings
M4(3) Category 3(b) – Sanitary Facilities
Different diagrams are provided illustrating accessible bathroom layouts and
clearances. Rooms take up significantly more space
46. Part Q - Security – 1st
October 2015
Including Change of Use
47. Potential problem?
Change of use: all accessible
windows and doors to be
changed!
Change of use, conservation
area, requires timber windows,
possibly even single glazed?
AD Q does not contain guidance
for relaxation in conservation
areas, listed and historical
buildings.
Unlike Appendix B for doors, no
alternative compliance methods
for windows…
So if they aren’t tested to specific
standards, how do they comply?
50. The Performance Gap -what is it?
the difference between the
intended energy performance
predicted by the designer, and the
actual energy performance when
the building is handed over and in
use.
How it’s built and occupied falls
short of expectations, and does not
meet the designed energy
standards (Part L).
Does it do what it
says on the tin?
51. The challenge…
“we require immediate pan-industry
activity to trigger a cultural shift so
that as-built performance becomes a
core element of delivering high
quality new housing”
ZERO CARBON HUB 2014
By forcing the planners to include in the local plan it allows the planning inspectorate to assess whether there is justification based on local need
Once the optional requirements are triggered it is enforceable by Building Control – not planning
The developer must inform the BC provider that optional requirements apply (creates level playing field with AI’s no need for BC to liaise with planning)
Expecting national guidelines on space provisions that can be referred to by planning authorities when issuing planning consents.
No detail on how this might work in practice.
Not going to be a B Reg requirement so we do not know if and how this will be enforced on site!
Straightforward guidance, minimum floor areas for dwellings, for individual rooms (see next slide), minimum ceiling height, minimum requirement for storage space.
Minimum bedrooms sizes are prescribed in the standard
Note only applied where there is a policy within a local plan!
Note only applied where there is a policy within a local plan! Regulations amended to include optional requirement mechanism. Where triggered, check to the higher standard of 110 l/p/p/d
This diagram suggests that the higher optional levels in Part G would be agreed by the planning inspectorate in the South East
Now can use tables in the App Doc to determine water usage rather than having to use the water calculator The choice is down to applicant. This means the water calculator does not have to be used.
This shows the options in the new App Doc – specify the standard fittings which will comply or use the calculator. There is 2 sets of standard fittings tables, one for 125 l/p/p/p/d one for 110
ADM is now split into 2 parts, dwellings and other. No change to ‘other’.
Mention new AD is in single column format to ease reading and improve clarity. New and improved diagrams for unchanged clauses in M4(1).
Slide describes how the 2 Part M’s are now split
Discuss here the 3 categories of dwelling
Category 1 – should be same as old Part M – there are a few subtle changes such as the ones underlined
Detail follows on next slides
In essence not intended to be any changes from old Part M for dwellings, but check out the underlined bits, particularly the issue regarding consumer units.
Remind this is primarily for people who can walk and so part k ‘general access stair’ needed to gain access to upper floors in a block of flats. Also that Cat 1 is intended to address people who visit rather than live in the dwelling
Moving on to the new categories Category 2 This is for accessible and adaptable dwellings
This section is clear there has to be step free access whereas M4(1) says step free where possible.
Also dwelling has to be capable of being adapted to increase accessibility and functionality of the dwelling in the future if needed by the occupant
This brings in blocks of flats and covers internal access that can be extended to access to any level in a multi storey building.
Note the point about access from a car, it can be outside the plot boundary but not outside the site development area.
It recognises that gates paths etc. may be involved, all of which have to be accessible
Where step free is not possible to main entrance there has to be an alternative entrance that is step free
Remind delegates to look at the small print to see if it is relevant to private only or communal situations
Car parking is now controlled (where provided) for individual dwellings or for blocks of flats
Requirements for communal entrances – highlight new requirements such as lighting and canopies, also leading edges retained for fixed distance into the corridor
Also required to have covered entrance and minimum lobby sizes – porch pictured would not comply on depth
If a compliant porch is provided no canopy is required – provided the door between porch and house is secure
If an exempt porch is provided over an M4(2) accessible door it is still exempt but is a material alteration to the dwelling and an alternative compliant entrance or a part m compliant porch solution is required because of the material alteration (regular question).
Key point here is that future provision for stairlift dictates minimum stair width of 850mm and also entrance storey living area with compliant window
Minimum requirements for bedroom layouts and sizes which are nothing to do with space standards but to do with accessibility. Appendix d gives furniture sizes to demonstrate compliance.
Describes minimum requirements and diagram gives examples. Dia 1.3 is the category 1 wc
Also covers the point about wall structure which is assumed to mean add some ply as per lifetime homes guide
Examples of compliant bathroom layouts – 1900 x 2150 is not huge. Bathroom can satisfy wc requirement also if on the entrance and principal bedroom storey
Category 3 Much more stringent requirements
Two types here - see next slide for more detail!
Wheelchair adaptable – Can be easily adaptable fro use by a person in a wheelchair
Wheelchair accessible- Built to be used by a person in a wheelchair
Note all areas step free and dwelling has to be adaptable for wheelchair use in the future where not already provided
This is one of the new optional requirements that can be imposed at planning stge. Unless developer tells you otherwise, always check 4(3)’s as an (a) type dwelling unless specifically asked for under planning conditions.
We will look principally at wheelchair adaptable dwellings (default position) and then explain the differences with wheelchair accessible dwellings should planning invoke that requirement
Extra provisions for the approach to the dwelling.
Note there are subtle changes here with Cat 2 – main change it includes garages and car ports in parking requirements
Includes parking – picture indicates non-compliance
Wider zones at side of space
Space must be level Cat 2 can be gently sloping
The 1200mm zone can be shared between adjacent spaces
Max gradient 1:15 Cat 2 is 1:12
Communal and private presented together – differences identified in slide text, otherwise the same
Key items are internal turning circle, provision for powered doors,
Key items – all external doors to be accessible, pictures indicate non-compliance
Note greater width to internal corridors 900 - 1050
Greater width to internal doors 750-850
Room for turning circles at main entrance door
Also more stringent requirements about where doors are located near corners
Key new requirement – provision for future installation of a through-floor lift (not stairlift, but that required too!), so consider trimming and wall positions, should be shown on plan.
Key new requirements – strengthened ceilings, minimum requirements on sizes of all bedrooms in the house as well as more manouevering space
This starts to get complicated – different requirements based on storeys and bed spaces, and also what you have got where – no explanation given as to houses of 4 or more storeys! The key point here is to always refer back to this table – you’ll not get it right if you try to remember it
Unless there is a bathroom on the entrance storey, w.c. must be a wet room
Bathroom sizes have increased somewhat from cat 2, now at 2.2 x 2.6. bath can be positioned over level access shower as can be removed at adaptation stage if required.
Outdoor spaces and key features must be accessible for independent living and quality of life. We now need to ensure access around the external part of the dwelling and to all external facilities
These are the key changes when we look at a 3b Wheelchair Accessible dwelling, mainly lift installed, radiator controls. Key differences to kitchen and bathroom design coming next. No changes to bedrooms
Quite specific requirements introduced for kitchen design.
Alternative diagrams are provided for wheelchair accessible bathrooms and positioning of sanitary facilities. No point going into detail – they won’t remember it
This introduces the new part q, with the requirement and a definition of ‘easily accessible’ to explain which windows and doors are controlled.
There is some comedy in there if you are so inclined regarding ‘casual or opportunist burglar’
Massive issue with change of use – applies to all accessible windows and doors, they’ll all need replacing. Massive cost, and issues with conservation. Doc Q contains no ‘get out’ for conservation but we will have to be practical and find a way to relax it anyway.
So now we know that Part L 2016 Zero Carbon, and the CfSH are both scrapped, what is next for energy efficiency?
LABC agree with Government and the ZC HUB that the unplanned hiatus in new legislation affords us the opportunity to focus on improving compliance with part L 2013
Emphasise the point ‘Does it do what it says on the tin?’ – it might apply to the paint, but is much less likely to apply to the house as a whole. Evidence suggests that we are falling way short of the energy use predicted. The actual energy use is usually around 66% more than the design predictions.
Introduce the ZCH Builders Book. It’s marvellous and should be promoted, although it only covers masonry (75% of new builds). The whole industry from designer to B Control, builder, manufacturer, service engineer and end user have to change to improve performance. The respite from 2016 Part L gives us the opportunity as an industry to get our house in order.