1 – Definition of Cables & Conductors
‫والموصالت‬‫الكابالت‬‫يف‬‫ر‬‫تع‬
:
‫أحادى‬ ‫موصل‬ ‫على‬ ‫الكابل‬ ‫يحتوى‬
(
single conductor
)
‫أكثر‬ ‫أو‬
‫التوصيل‬ ‫أحادية‬ ‫األسالك‬ ‫من‬ ‫مجموعة‬ ‫هو‬ ‫والموصل‬
2 – Cable Classifications
‫ـالت‬‫ـ‬‫ـ‬‫ـ‬‫ب‬‫الكا‬‫ـواع‬‫ـ‬‫ـ‬‫ـ‬‫ن‬‫ا‬
:
2. 1 Low Voltage Cables (0.6/1-1.2)k.v
‫المنخفض‬ ‫الجهد‬‫كابالت‬
:
(
‫المحلى‬ ‫لالنتاج‬ ‫طبقا‬
)
*
‫الـ‬ ‫بمادة‬ ‫معزولة‬ ‫كابالت‬
(
PVC
: )
-
Single core cables with solid or stranded
capper conductors and PVC insulated
1
-
‫موصالت‬ ‫ذات‬ ‫القطب‬ ‫أحادية‬ ‫نحاس‬ ‫كابالت‬
‫بمادة‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫أو‬ ‫مصمتة‬
‫الـ‬
PVC
‫رقم‬ ‫شكل‬
(
1
)
Single core cables with flexible copper
conductors and PVC insulated
2
-
‫مرنة‬ ‫نحاس‬ ‫موصالت‬ ‫ذو‬ ‫القطب‬ ‫أحادى‬ ‫كابل‬
(
‫شعر‬
)
‫الـ‬ ‫بمادة‬ ‫ومعزولة‬
PVC
‫رقم‬ ‫شكل‬
(
2
)
Multi core cable with flexible copper
conductors PVC insulated and PVC
sheathed
3
-
‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫كابالت‬
‫مرنة‬
(
‫شعر‬
)
‫الـ‬ ‫بمادة‬ ‫ومعزولة‬
PVC
‫ومغلفة‬
‫الـ‬ ‫بمادة‬
PVC
‫رقم‬ ‫شكل‬
(
3
)
Single core cable ,with stranded circular
copper conductors, PVC insulated and
PVC sheathed
4
-
‫من‬ ‫مكونة‬ ‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫أحادية‬ ‫كابالت‬
‫الـ‬ ‫بمادة‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬
PVC
‫ومغلفة‬
‫الـ‬ ‫بمادة‬
PVC
‫رقم‬ ‫شكل‬
(
4
)
Multi core cables with stranded copper
conductors PVC insulated and PVC
sheathed
5
-
‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫نحاس‬ ‫كابالت‬
‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫من‬ ‫مكونة‬ ‫نحاس‬
‫بالـ‬
PVC
‫الـ‬ ‫بمادة‬ ‫ومغلفة‬
PVC
‫رقم‬ ‫شكل‬
(
5
)
Multi core cables with stranded
Aluminum conductors , PVC insulated
and PVC sheathed .
6
-
‫ألومنيوم‬ ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫كابالت‬
‫بمادة‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫من‬ ‫مكونة‬
‫الـ‬
PVC
‫بال‬ ‫ومغلفة‬
PVC
‫رقم‬ ‫شكل‬
(
6
)
Multi core cables with stranded copper
conductors ,PVC insulated , steel tape
armoured and PVC sheathed
7
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
PVC
‫ومسلحة‬
‫بشريط‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
7
)
Multi core cables with stranded
Aluminum conductors , PVC insulated ,
steel tape armoured and PVC sheathed
8
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫ألومونيو‬
‫م‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
PVC
‫ومسلحة‬
‫بشريط‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
8
)
Multi core cables with stranded copper
conductors , PVC insulated , steel wires
armoured and PVC sheathed
9
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
PVC
‫ومسلحة‬
‫بأسالك‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
9
)
Multi core cables with stranded
Aluminum conductors , PVC insulated ,
steel wires armoured and PVC sheathed
10
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫ألومونيو‬
‫م‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
PVC
‫ومسلحة‬
‫بأسالك‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
10
)
‫كابالت‬
‫معزولة‬
‫بمادة‬
‫الـ‬
(
XLPE
)
-:
Single core cables with stranded circular
copper conductors, XLPE insulated ,
and PVC sheathed
11
-
‫كابالت‬
‫نحاس‬
‫أحادية‬
‫القطب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫دائرية‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
,
XLPE
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
11
)
Multi core cables with stranded circular
Copper conductors, XLPE insulated ,
and PVC sheathed
12
-
‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫كابالت‬
‫بما‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫من‬ ‫مكونة‬ ‫دائرية‬
‫دة‬
‫الـ‬
XLPE
‫الـ‬ ‫بمادة‬ ‫ومغلفة‬
PVC
‫رقم‬ ‫شكل‬
(
12
)
Multi core cables with stranded circular
Aluminum conductors , XLPE insulated
, and PVC sheathed .
13
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫ألومونيوم‬
‫دائرية‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
13
)
Multi core cables with stranded circular
copper conductors , XLPE insulated,
steel tape armoured , and PVC sheathed
.
14
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫دائرية‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫معزولة‬
‫بما‬
‫دة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بشريط‬
‫صلب‬
‫ومغلفة‬
‫بم‬
‫ادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
14
)
Multi core cables with stranded circular
Aluminum conductors ,XLPE insulated
steel tape armoured and PVC sheathed
15
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫ألومونيوم‬
‫دائرية‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بشريط‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
15
)
Multi core cables , with stranded copper
conductors , XLPE insulated steel tape
armoured and PVC sheathed
16
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫مكونة‬
‫من‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بأسالك‬
‫صلب‬
‫المغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
16
)
Multi core cables , with stranded
Aluminum conductors , XLPE insulated
steel tape armored and PVC sheathed
17
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫ألومونيوم‬
‫عبارة‬
‫عن‬
‫شعيرات‬
‫صلبة‬
‫ومعزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بأسالك‬
‫صلب‬
‫ومغلف‬
‫ة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
17
)
‫رقم‬‫شكل‬
(
1
)
‫رقم‬‫شكل‬
(
2
)
‫رقم‬‫شكل‬
(
3
)
‫رقم‬‫شكل‬
(
4
)
‫رقم‬‫شكل‬
(
5
)
‫رقم‬‫شكل‬
(
6
)
‫رقم‬‫شكل‬
(
7
)
‫رقم‬‫شكل‬
(
8
)
‫رقم‬‫شكل‬
(
9
)
‫رقم‬‫شكل‬
(
10
)
‫رقم‬‫شكل‬
(
11
)
‫رقم‬‫شكل‬
(
12
)
‫رقم‬‫شكل‬
(
13
)
‫رقم‬‫شكل‬
(
14
)
‫رقم‬‫شكل‬
(
15
)
‫رقم‬‫شكل‬
(
16
)
‫رقم‬‫شكل‬
(
17
)
2.2Medium voltage cables ‫المتوسط‬‫الجهد‬‫كابالت‬
:
From ( 6 --- 36) K.V
*
‫التشغيل‬‫لجهد‬ ً‫طبقا‬‫الكابالت‬‫نواع‬‫ا‬
:
-
(6 / 10 – 12 ) K.V
(8.7 / 15- 17.5) K.V
(12 / 20 – 24 ) K.V
( 18 / 30 – 36 ) K.V
‫والتسليح‬ ‫العزل‬‫لنوع‬‫طبقا‬‫الكابالت‬‫نواع‬‫ا‬‫يلى‬‫وفيما‬
:
-
‫المحلى‬‫لالنتاج‬‫وطبقا‬
Single & multi core copper conductor XLPE
insulated and PVC sheathed
16
-
‫كابالت‬
‫أحادية‬
‫القطب‬
‫ومتعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫ألمونيوم‬
‫معزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
18
)
Single & multi core Aluminum conductor
XLPE insulated and PVC sheathed
17
-
‫كابالت‬
‫أحادية‬
‫القطب‬
‫ومتعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫معزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
19
)
Multi core copper & Aluminum conductor
XLPE insulated , steel tape armoured and
PVC sheathed
18
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫أوألومنيوم‬
‫معزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بشريط‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
20
)
Multi core copper & Aluminum conductor
XLPE insulated , steel wire armoured and
PVC sheathed.
19
-
‫كابالت‬
‫متعددة‬
‫األقطاب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫أوألومنيوم‬
‫معزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بأسالك‬
‫صلب‬
‫ومغلفة‬
‫بمادة‬
‫الـ‬
PVC
‫شكل‬
‫رقم‬
(
21
)
‫رقم‬‫شكل‬
(
18
)
‫رقم‬‫شكل‬
(
19
)
‫رقم‬‫شكل‬
(
20
)
‫رقم‬‫شكل‬
(
21
)
2
.3
‫العالى‬ ‫الجهد‬ ‫كابالت‬
:
:
38
/
66
-
72.5
) K.V
)
High voltage cables
Single core copper conductors , XLPE
insulated , copper screened and HDPE
sheathed
1
-
‫بمادة‬ ‫معزولة‬ ‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫القطب‬ ‫أحادى‬ ‫كابل‬
‫الـ‬
XLPE
‫ب‬ ‫ومغلفة‬ ‫النحاس‬ ‫من‬ ‫شبك‬ ‫بسلك‬ ‫ومسلحة‬
‫مادة‬
‫ال‬
HDPE
‫رقم‬ ‫شكل‬
(
22
)
Single core copper conductors , XLPE
insulated , Lead screened and HDPE
sheathed
2
-
‫كابل‬
‫أحادى‬
‫القطب‬
‫ذات‬
‫موصالت‬
‫نحاس‬
‫معزولة‬
‫بمادة‬
‫الـ‬
XLPE
‫ومسلحة‬
‫بسلك‬
‫شبك‬
‫من‬
‫الرصاص‬
‫ومغلف‬
‫ة‬
‫بمادة‬
‫ال‬
HDPE
‫شكل‬
‫رقم‬
(
23
)
‫رقم‬‫شكل‬
(
22
)
‫رقم‬‫شكل‬
(
22
)
‫الكهربائى‬ ‫الحمل‬
:
Electrical Load
‫يجب‬
‫اختيار‬
‫مساحة‬
‫مقطع‬
‫الكابل‬
‫بحيث‬
‫ال‬
‫تقل‬
‫سعته‬
‫لحمل‬
‫التيار‬
‫الكهربائى‬
‫عن‬
‫أقصى‬
‫تيار‬
‫تغذية‬
‫وكذا‬
‫يجب‬
‫أال‬
‫تتعدى‬
‫درجة‬
‫حرارة‬
‫الكابل‬
‫المناظرة‬
‫لسعة‬
‫حمل‬
‫الت‬
‫يار‬
‫الكهربائى‬
‫عن‬
‫الدرجة‬
‫المناسبة‬
‫لنوعية‬
‫عزل‬
‫الكابل‬
‫المستخدم‬
.
‫يجب‬
‫أن‬
‫تكون‬
‫الكابالت‬
‫الموصلة‬
‫على‬
‫التوازى‬
‫من‬
‫نفس‬
‫النوع‬
‫ولها‬
‫نف‬
‫س‬
‫مساحة‬
‫المقطع‬
‫والطول‬
‫بحيث‬
‫تحمل‬
‫فعليا‬
‫تيارات‬
‫متساوية‬
.
‫عند‬
‫تحديد‬
‫سعة‬
‫حمل‬
‫التيار‬
‫للكابالت‬
‫غير‬
‫المعزولة‬
‫يجب‬
‫أن‬
‫يؤخذ‬
‫فى‬
‫االعتبار‬
‫الترتيبات‬
‫الالزمة‬
‫لتمددها‬
‫وانكماشها‬
‫والخواص‬
‫الطبيعية‬
‫للمعدن‬
‫المصنوعة‬
‫منه‬
‫ويوصى‬
‫أال‬
‫تتعدى‬
‫أقصى‬
‫درجة‬
‫حرارة‬
‫الستخدام‬
‫الكابالت‬
‫غير‬
‫المعزولة‬
90ْ
‫م‬
.
‫اذا‬
‫كان‬
‫من‬
‫الالزم‬
‫مد‬
‫كابل‬
‫بطول‬
‫محدد‬
‫فى‬
‫وسط‬
‫ينتظر‬
‫أن‬
‫يتم‬
‫عزله‬
‫حرار‬
‫يا‬
‫فيجب‬
‫تثبيت‬
‫الكابل‬
‫بحيث‬
‫ال‬
‫يتم‬
‫تغطيته‬
‫بالعزل‬
‫الحرارى‬
‫كلما‬
‫أمكن‬
‫ذلك‬
‫وفى‬
‫حا‬
‫لة‬
‫تعذر‬
‫ذلك‬
‫يجب‬
‫تخفيض‬
‫سعة‬
‫حمل‬
‫التيار‬
‫للكابل‬
‫بنسبة‬
‫مالئمة‬
.
‫الجهد‬ ‫هبوط‬
:
Voltage Drop
‫يجبْحسابْمساحةْمقطعْكلْكابلْغيرْمعزولْأوْمعزولْبماْالْيسمحْب‬
ْ‫تعدىْهبوطْالجهد‬
‫منْنقطةْالتغذيةْالكهربائيةْحتىْأقصىْنقطةْفىْهذهْالتركيبات‬
ْ‫نسبة‬
2.5
%
ْ‫منْالجهد‬
‫األسمىْوذلكْعندْالحملْالكابلْللموصالتْوذلكْطبقاْللكودْالمصرى‬
.
‫التعادل‬ ‫موصل‬ ‫مقطع‬ ‫مساحة‬
Neutral Cross Section
‫فى‬
‫الدوائر‬
‫متعددة‬
‫األطوار‬
‫التى‬
‫يحتمل‬
‫فيها‬
‫حدوث‬
‫عدم‬
‫توازن‬
‫األحمال‬
‫ف‬
‫ى‬
‫األطوار‬
‫الثالثة‬
‫فى‬
‫حالة‬
‫االستخدام‬
‫العادى‬
‫بسبب‬
‫االختالف‬
‫الكبير‬
‫فى‬
‫تيار‬
‫الحمل‬
‫أو‬
‫مع‬
‫امل‬
‫القدرة‬
‫فى‬
‫األطوار‬
‫المختلفة‬
‫أو‬
‫تواجد‬
‫تيارات‬
‫توافقية‬
( harmonics)
‫محسوسة‬
‫فى‬
‫األطوار‬
‫المختلفة‬
‫فيج‬
‫ب‬
‫اختيار‬
‫موصل‬
‫تعادل‬
‫ذى‬
‫مساحة‬
‫مقطع‬
‫كافية‬
‫مساوية‬
‫لمقطع‬
‫الوجة‬
‫لل‬
‫كابل‬
‫لحمل‬
‫أقصى‬
‫تيار‬
‫يحتمل‬
‫أن‬
‫يمر‬
‫فيه‬
.
‫فى‬
‫الدوائر‬
‫متعددة‬
‫األطوار‬
(
3
-phase)
‫التى‬
‫ال‬
‫يحتمل‬
‫حدوث‬
‫عدم‬
‫اتزان‬
‫ملحوظ‬
‫بها‬
‫أث‬
‫ناء‬
‫االستخدام‬
‫العادى‬
(
‫باستثناء‬
‫دوائر‬
‫االضاءة‬
‫بالتفريغ‬
)
‫فإنه‬
‫يمكن‬
‫ا‬
‫ستخدام‬
‫الكابالت‬
‫متعددة‬
‫األقطاب‬
‫التى‬
‫لها‬
‫موصل‬
‫تعادل‬
‫ذو‬
‫مساحة‬
‫مقطع‬
‫أصغر‬
‫من‬
‫المطلوب‬
‫فى‬
‫ح‬
‫الة‬
(
‫أ‬
)
‫بعاليه‬
.
‫المغذيات‬
:
Feeders
‫يجبْأنْتكونْقطاعاتهاْمناسبةْلنقلْاألحمالْالفعليةْالمطلو‬
ْ‫بة‬
+
25
%
ْ‫احتياطى‬
‫االسمى‬ ‫التيار‬
:
Nominal current
‫يرجعْالىْجداولْتحميلْاالسالكْوالكابالتْطبقاْللتصنيعْم‬
ْ‫عْمراعاةْتعديلْأحمال‬
‫الكابالتْطبقاْلدرجةْحرارةْالجوْوعددْالكابالتْفىْالمسارْالواح‬
ْ‫د‬
.
‫الجهد‬ ‫هبوط‬
:
Voltage Drop
‫يتم‬
‫تصميم‬
‫المغذيات‬
‫الرئيسية‬
‫والثانوية‬
‫والفرعية‬
‫بحي‬
‫ث‬
‫ال‬
‫تتجاوز‬
‫الهبوط‬
‫الكلى‬
‫فى‬
‫الجهد‬
‫بين‬
‫نقطة‬
‫التغذية‬
‫الرئيسية‬
‫للجهد‬
‫المنخفض‬
‫بالمب‬
‫نى‬
‫وأى‬
‫نقطة‬
‫تغذية‬
‫فى‬
‫التركيبات‬
‫عن‬
2.5
%
‫من‬
‫الجهد‬
‫األسمى‬
‫للتغذية‬
‫وذلك‬
‫عند‬
‫مرور‬
‫أقصى‬
‫قيمة‬
‫منتظرة‬
‫لتيار‬
‫التشغيل‬
‫الفعلى‬
‫فى‬
‫هذه‬
‫الموصالت‬
.
‫ويستثنى‬
‫من‬
‫ذلك‬
‫المغذيات‬
‫الخاصة‬
‫بتشغيل‬
‫المحركات‬
‫حيث‬
‫يسمح‬
‫بهبوط‬
‫فى‬
‫الجهد‬
‫حتى‬
5
%
‫من‬
‫الجهد‬
‫األسمى‬
‫للتغذية‬
‫عند‬
‫الحمل‬
‫الكامل‬
.
Neutral conductor cross section in 3 phase-systems
‫األط‬ ‫ثالثية‬ ‫المغذيات‬ ‫فى‬ ‫التعادل‬ ‫موصل‬ ‫مقطع‬
‫وار‬
.
‫يرتبطْمقطعْالموصلْالمتعادلْبمقطعْموصلْالطورْفىْالم‬
ْ‫غذياتْثالثية‬
‫األطوارْعلىْالوجةْالتالى‬
:
-
ْ‫اذاْكانْمقطعْموصلْالطورْفىْحدود‬
16
‫مم‬
2
ْ‫نختارْموصلْالتعادلْبنفس‬
ْ‫مقطعْموصلْْالطور‬
(phase)
ْ‫اذاْتراوحْمقطعْموصلْالطورْبين‬
(
35
‫مم‬
2
ْ،
25
‫مم‬
2
)
ْ‫يحتارْموصلْالتعادل‬
‫بمقطعْالْيقلْعنْالمقطعْالتالىْفىْالصغرْلمقطعْموصل‬
ْ‫الطور‬
.
ْ‫اذاْكانْموصلْالطورْالْيقلْعن‬
50
‫مم‬
2
‫نختارْموصلْالتعادلْبمقطعْالْي‬
ْ‫قل‬
ْ‫عنْنصفْمقطعْموصلْالطور‬
‫مثال‬
( :
3
×
50
+
25
‫مم‬
2
)
ْ،
(
3
×
70
+
35
‫مم‬
2
)
4.5 Cross section of conductors in branch lighting circuits
‫النهائية‬ ‫الفرعية‬ ‫الدوائر‬ ‫موصالت‬ ‫مقطع‬
(
‫االضاءه‬ ‫دوائر‬ ‫فى‬
)
‫عند‬
‫تصميم‬
‫مقطع‬
‫موصالت‬
‫الدوائر‬
‫الفرعية‬
‫النهائية‬
‫التى‬
‫تغذى‬
‫عددا‬
‫م‬
‫ن‬
‫مخارج‬
‫االضاءه‬
‫أو‬
‫المآخذ‬
‫الكهربائية‬
‫المخصصة‬
‫لألجهزة‬
‫الكهربائية‬
‫االضاءه‬
‫يراعى‬
‫اآلتى‬
:
‫يحسب‬
‫الحمل‬
‫الفعلى‬
‫لكل‬
‫مخرج‬
‫اضاءه‬
‫أو‬
‫مأخذ‬
(
‫بريزه‬
)
‫على‬
‫أساس‬
100
‫وات‬
‫لكل‬
‫مخرج‬
‫على‬
‫األقل‬
‫مهما‬
‫كان‬
‫الحمل‬
‫الفعلى‬
‫أقل‬
‫من‬
‫ذلك‬
‫أما‬
‫اذا‬
‫زاد‬
‫الحمل‬
‫الفعلى‬
‫عن‬
‫ذلك‬
‫فيحسب‬
‫على‬
‫أساس‬
‫الحمل‬
‫الفعلى‬
.
‫فى‬
‫حالة‬
‫األحمال‬
‫الحثية‬
(
‫ذات‬
‫الملفات‬
)
‫أو‬
‫المصابيح‬
‫التى‬
‫تعمل‬
‫بالتف‬
‫ريغ‬
‫الكهربائى‬
‫وتدخل‬
‫فى‬
‫دائرتها‬
‫ملفات‬
‫حثيه‬
‫يحسب‬
‫التيار‬
‫على‬
‫أساس‬
125
%
‫من‬
‫التيار‬
‫الفعلى‬
‫المار‬
‫بالدائرة‬
.
ْ
‫ا‬‫ال‬‫فمث‬
‫فى‬
‫حالى‬
‫مصباح‬
‫فللورى‬
‫قدره‬
40
‫وات‬
(
‫يدخل‬
‫فى‬
‫دائرتة‬
‫ملف‬
‫حثى‬
)
‫لتشغيله‬
‫م‬
‫ن‬
‫مصدر‬
‫التيار‬
‫المتردد‬
‫جهده‬
(
220
‫فولت‬
)
‫يمر‬
‫فى‬
‫دائرتة‬
‫تيار‬
‫شدته‬
0.42
‫أمبير‬
(
‫باعتبار‬
‫معامل‬
‫القدرة‬
0.43
)
‫يحسب‬
‫مقطع‬
‫موصل‬
‫الدائرة‬
‫على‬
‫أساس‬
‫تيار‬
‫شدته‬
0.52
‫أمبير‬
‫أى‬
1.25
‫التيار‬
‫الفعلى‬
‫وذلك‬
‫اذا‬
‫لم‬
‫يزود‬
‫المصباح‬
‫بمكثف‬
‫تحسين‬
‫القدرة‬
.
‫أما‬
‫اذا‬
‫زود‬
‫بمكثف‬
‫تحسين‬
‫معامل‬
‫القدرة‬
‫يمر‬
‫فى‬
‫دائرة‬
‫المصباح‬
‫تيار‬
‫فى‬
‫حدود‬
0.23
‫أمبير‬
(
‫باعتبار‬
‫معامل‬
‫القدرة‬
0.8
)
‫ويحسب‬
‫مقطع‬
‫موصل‬
‫الدائرة‬
‫على‬
‫أساس‬
‫تيار‬
‫شدته‬
0.29
‫أمبير‬
‫أى‬
1.25
‫من‬
‫التيار‬
‫الفعلى‬
.
‫ال‬
‫يقل‬
‫مقطع‬
‫موصالت‬
‫الدوائر‬
‫الفرعية‬
‫النهائية‬
‫والمخارج‬
‫لالنارة‬
‫عن‬
2
‫مم‬
2
‫والبرايز‬
‫عن‬
3
‫مم‬
2
‫مهما‬
‫كان‬
‫حملها‬
‫الفعلى‬
ْ
‫ا‬‫ا‬‫صغير‬
.
‫تكون‬
‫موصالت‬
‫كل‬
‫دائرة‬
‫فرعية‬
‫نهائية‬
‫منفصله‬
ْ
‫ا‬‫ا‬‫تمام‬
‫عن‬
‫موصالت‬
‫أيه‬
‫د‬
‫ائرة‬
‫أخرى‬
‫وال‬
‫تشترك‬
‫معها‬
‫فى‬
‫أى‬
‫جزء‬
‫منها‬
‫حتى‬
‫فى‬
‫الموصالت‬
‫المتصلة‬
‫بقطب‬
‫التعادل‬
.

‫يجوزْاشتراكْموصالتْدائرتينْفرعيتينْنهائيتينْفىْماسورة‬
ْ‫واحدةْبشرطْأنْتكونْكل‬
ْ‫منهاْمغذاهْمنْنفسْالطورْمنْمصدرْالتغذية‬
.
4.6 Branch circuits for( sockets & lighting outlets)
‫والمآخذ‬ ‫االضاءه‬ ‫وحدات‬ ‫لمخارج‬ ‫النهائية‬ ‫الفرعية‬ ‫الدوائر‬
:

‫يراعى‬
‫تحميل‬
‫مخارج‬
‫المآخذ‬
‫الكهربائية‬
‫على‬
‫دوائر‬
‫فرعية‬
‫نهائية‬
‫م‬
‫ستقلة‬
‫عن‬
‫الدوائر‬
‫الفرعية‬
‫النهائية‬
‫الخاصة‬
‫بمخارج‬
‫االناره‬
.

‫يراعى‬
‫أال‬
‫يزيد‬
‫عدد‬
‫مخارج‬
‫االنارة‬
‫أو‬
‫المأخذ‬
‫الكهربائية‬
‫التى‬
‫تستعم‬
‫ل‬
‫ألجهزة‬
‫االنارة‬
‫والتى‬
‫تحمل‬
‫على‬
‫دائرة‬
‫فرعية‬
‫نهائية‬
‫واحدة‬
‫عن‬
‫عشرة‬
‫مخارج‬
.

‫ال‬
‫يزيد‬
‫مقطع‬
‫الموصالت‬
‫التى‬
‫تغذى‬
‫مخارج‬
‫االنارة‬
‫والمأخذ‬
‫عن‬
‫مقطع‬
‫الدوائر‬
‫الفرعية‬
‫النهائية‬
‫التى‬
‫تغذيها‬
.
5 . Maximum demand and diversity factor
‫التباين‬ ‫ومعامل‬ ‫المطلوب‬ ‫األقصى‬ ‫الحمل‬
:
‫الك‬ ‫للتركيبات‬ ‫المطلوب‬ ‫األقصى‬ ‫الحمل‬ ‫حساب‬ ‫طريقة‬
‫بتغذية‬ ‫تقوم‬ ‫والتى‬ ‫هربائية‬
‫معامل‬ ‫تطبيق‬ ‫الى‬ ‫باالضافة‬ ‫االستخدام‬ ‫شائعة‬ ‫األجهزة‬
‫المسموح‬ ‫التباين‬
:
-
1
-
‫يحسب‬
‫التيار‬
‫األقصى‬
‫المطلوب‬
‫للدوائر‬
‫النهائية‬
‫الفرعية‬
‫ب‬
‫جميع‬
‫تيارات‬
‫كافة‬
‫نقط‬
‫االستخدام‬
(
‫المآخذ‬
‫والبرايز‬
)
‫واألجهزة‬
‫الثابتة‬
‫على‬
‫الدوائر‬
‫مع‬
‫ت‬
‫طبيق‬
‫معامل‬
‫التباين‬
‫طبقا‬
‫لما‬
‫هو‬
‫موضح‬
‫بالجدول‬
(
1
)
.
2
-
‫يتم‬
‫تحديد‬
‫التيار‬
‫الفعلى‬
‫المطلوب‬
‫لدائرة‬
‫تغذى‬
‫مجموعة‬
‫دوائ‬
‫ر‬
‫عمومية‬
(
‫نهائية‬
)
‫باستعمال‬
‫معامالت‬
‫التباين‬
‫الموضحة‬
‫فى‬
‫الجدول‬
(
2
)
‫التى‬
‫تطبق‬
‫على‬
‫التيارات‬
‫الفعلية‬
‫لجميع‬
‫األجهزة‬
‫المغذاه‬
‫بهذه‬
‫الدائرة‬
‫وليس‬
‫بجمع‬
‫التي‬
‫ار‬
‫الفعلى‬
‫للدوائر‬
‫العمومية‬
‫النهائية‬
‫المغذاه‬
.
3
-
‫بعد‬
‫تحديد‬
‫تيار‬
‫التصميم‬
‫لجميع‬
‫الدوائر‬
‫يتم‬
‫تحديد‬
(
‫اختب‬
‫ار‬
)
‫مقطع‬
‫موصالت‬
‫الدوائر‬
‫ويجب‬
‫مراجعة‬
‫الحد‬
‫المسموح‬
‫به‬
‫فى‬
‫هبوط‬
‫الجهد‬
.
‫جدول‬
(
1
)
‫التيار‬ ‫تقدير‬
‫اإلستخدام‬ ‫لنقط‬ ‫الكهربى‬
‫الكهربائية‬ ‫واألجهزة‬
‫المصــرى‬ ‫للكـود‬ ً‫ا‬‫طبق‬
‫المصرى‬ ‫للكود‬ ً‫طبقا‬ 2
‫جدول‬ ‫تابع‬
(
2
)
‫حاالت‬
‫معامالت‬ ‫بإستخدام‬ ‫السماح‬
‫التباين‬
‫الموصالت‬ ‫مقاطع‬ ‫لحساب‬
‫لألغراض‬ ‫الكهربائية‬
‫المختلفة‬ ‫والمنشآت‬
‫المصرى‬ ‫للكود‬ ‫طبقا‬
6 . Circuit design ‫الدوائر‬ ‫تصميم‬
‫فيماْيلىْكيفيةْتصميمْالدوائرْالمختلفةْوحسابْمقاطعْالموصالتْوالكاب‬
ْ‫التْحتىْيمكنْتحديدْأجهزة‬
(
‫نبائط‬
)
ْ‫الوقايةْضدْزيادةْالحملْوقصرْالدائرة‬
.
*
-
‫التالية‬ ‫األساسية‬ ‫للخطوات‬ ‫طبقا‬ ‫الحسابات‬ ‫تتم‬
:
-
‫األولى‬ ‫الخطوة‬
:
ْ‫تحديدْقيمةْالتيارْالتصميمى‬
(
I
)
(
design current
)
‫الثانية‬ ‫الخطوة‬
:
ْْْْْْْْْْْْْْْْْْْ‫اختيارْتيارْالوقاية‬
(
In
)
( protection current )
‫الثالثة‬ ‫الخطوة‬
:
ْْ‫اختيارْمعامالتْالتصحيحْالمناسبةْلكلْحالة‬
Relevant correction factors
‫الرابعة‬ ‫الخطوة‬
:
ْ‫حسابْمعاملْالتصحيحْالكلى‬
(C.F )
total correction factor
calculation
of
Cable current carrying capacity (IZ ) ‫الخامسة‬ ‫الخطوة‬
:
‫حسابْالسعةْالتياريةْل‬
‫لكابل‬
Iz
‫التالية‬ ‫البنود‬ ‫مراجعة‬ ‫تتم‬
:
.1
ْ‫اختيارْمساحةْمقطعْالكابلْالمناسبْللتيار‬
( Iz )
.2
ْ‫مراجعةْالهبوطْفيْالجهد‬
.3
‫حسابْتياراتْالقصر‬
F
C
In
.

‫االولى‬ ‫الخطوه‬
:
‫التصميمي‬ ‫التيار‬ ‫قيمة‬ ‫تحديد‬
Nominal current
‫التيار‬
(
‫الطور‬ ‫احادي‬
)
I
‫فاءة‬‫الك‬
‫فى‬
‫حالة‬
‫القدرة‬
‫التى‬
‫بها‬
‫اء‬‫ز‬‫ج‬‫ا‬
‫متحركة‬
:

‫قدرة‬
‫الخرج‬
‫بالوات‬
P:
(Output power)
(
220
‫فولت‬
)
‫الجهد‬
‫بالفولت‬
v:
(Nominal voltage)
‫معامل‬
‫القدرة‬
P.F:
(Power factor)




F
P
V
P
.
I
*
‫الثانية‬ ‫الخطوة‬
:
‫الوقاية‬ ‫تيار‬ ‫قيمة‬ ‫تحديد‬
In
protection current
ْ‫بعدْتحديدْنسبةْالتيارْالتصميمى‬
I
ْ‫يلزمْاختيارْقيمةْتيارْالوقاية‬
In
ْ‫بحيثْيكون‬
In>I
ْ‫ويتمْاختيارْالتيار‬
In
‫منْالجداولْالخاصةْبتحميلْالكابالتْالتىْيتمْاعدادهاْبواس‬
ْ‫طةْالشركاتْالمنتجة‬
ْ‫لها‬
6.3 choice of Correction factor
*
‫الثالثة‬ ‫الخطوة‬
:
‫التصحيح‬ ‫معامالت‬ ‫اختيار‬
C.F
‫حالة‬ ‫لكل‬ ‫المناسبة‬
:
-
ْ‫عندماْيمرْتيارْالحملْالكامل‬
(full load)
‫ْوهذ‬‫ا‬‫ا‬‫فىْموصلْمعزولْأوْكابلْفإنهْيصبحْدافئ‬
ْ‫اْالْيسبب‬
‫عادةْأىْمشاكلْاالْفىْحالةْتعرضهْالرتفاعْآخرْفىْدرجةْالحرارةْكنتيجةْلمؤث‬
ْ‫راتْأخرىْمماْيؤدى‬
ْ‫إلىْارتفاعْزائدْفىْدرجةْالحرارةْمماْقدْيؤدىْالىْانهيارْالعزل‬
‫هى‬ ‫األخرى‬ ‫والمؤثرات‬
:

ْ‫ارتفاعْدرجةْحرارةْالوسطْالمحبط‬

‫تجميعْالكابالتْمعاْفىْمكانْمغلق‬

‫التعرضْلتيارْزائدْلمدةْطويله‬

ْ‫المالمسةْمعْمادةْعازلةْللحرارة‬
.
‫ولكل‬
‫من‬
‫هذه‬
‫المؤثرات‬
‫معامل‬
‫تصحيح‬
‫يؤدى‬
‫الى‬
‫خفض‬
‫قيمة‬
‫أقصى‬
‫تيار‬
‫ويتم‬
‫حساب‬
‫هذه‬
‫القيمة‬
‫على‬
‫النحو‬
‫التالى‬
:
-
‫معامل‬
‫تأثير‬
‫درجة‬
‫حرارة‬
‫الوسط‬
‫المحيط‬
(Ca)
‫ويرجع‬
‫فى‬
‫تحديده‬
‫الى‬
‫جدول‬
‫رقم‬
(
3
)
‫معامل‬
‫تجميع‬
‫الكابالت‬
(grouping )
‫فى‬
‫مسار‬
‫واحد‬
“Cg”
‫حيث‬
‫يؤدى‬
‫تجميع‬
‫الكابال‬
‫ت‬
‫معا‬
‫الى‬
‫أن‬
‫تبث‬
‫حرارتها‬
‫وتؤثر‬
‫على‬
‫بعضها‬
‫البعض‬
‫ويرجع‬
‫فى‬
‫تحدي‬
‫د‬
‫هذا‬
‫المعامل‬
‫الى‬
‫جدول‬
‫رقم‬
(
4
)
‫مع‬
‫مالحظة‬
‫األتى‬
:
‫الجدول‬
‫رقم‬
(
4
)
‫محسوب‬
‫لعدد‬
‫من‬
‫الكابالت‬
‫موجوده‬
‫بجوار‬
‫بعضها‬
‫وذات‬
‫مق‬
‫اطع‬
‫متساوية‬
.
‫من‬
‫الحاالت‬
‫المتكررة‬
‫والتى‬
‫تتطلب‬
‫تطبيق‬
‫معامل‬
‫تجميع‬
‫الكابال‬
‫ت‬
‫هى‬
‫التغذية‬
‫الكهربائية‬
‫لدوائر‬
‫إنارة‬
‫المصانع‬
‫الكبيرة‬
‫حيث‬
‫يتم‬
‫تمديد‬
‫الكابالت‬
‫على‬
‫حوام‬
‫ل‬
‫أو‬
‫داخل‬
‫نظام‬
‫للصندوق‬
‫وتكون‬
‫الكابالت‬
‫فى‬
‫هذه‬
‫الحالة‬
‫ذات‬
‫مقاطع‬
‫متساوية‬
‫ويت‬
‫م‬
‫تحميلها‬
‫بالتيار‬
‫الفعلى‬
‫الكلى‬
‫فى‬
‫نفس‬
‫الوقت‬
.
‫اذا‬
‫تمت‬
‫الوقاية‬
‫باستخدام‬
‫مصاهر‬
‫ذات‬
‫خواص‬
‫خاصة‬
‫وبطيئة‬
‫زمنيا‬
‫ط‬
‫بقا‬
‫للمواصفات‬
(IEC-269-3)
‫فيتم‬
‫اختيار‬
‫التيار‬
‫المقنن‬
In
‫بحيث‬
‫يكون‬
‫أقل‬
‫من‬
‫أو‬
‫مساوى‬
‫للقيم‬
‫ة‬
(
0.725
Iz)
‫أى‬
‫كالتالى‬
:
In< 0.725Iz
‫هو‬ ‫المقنن‬ ‫المصهر‬ ‫تيار‬ ‫أن‬ ‫حيث‬
In
‫ويكون‬
‫معامل‬
‫التصحيح‬
Cf
‫الذى‬
‫ينبغى‬
‫تطبيقه‬
‫فى‬
‫هذه‬
‫الحالة‬
‫مساويا‬
‫للقيمة‬
0.725
‫معامل‬
‫المالمسة‬
‫مع‬
‫عزل‬
‫حرارى‬
(
thermal insulation
)
‫مع‬
‫زيادة‬
‫االتجاة‬
‫الى‬
‫ترشيد‬
‫استهالك‬
‫الطاقة‬
‫وذلك‬
‫باستخدام‬
‫مواد‬
‫عازلة‬
‫فى‬
‫البناء‬
‫فإنه‬
‫يجب‬
‫أخذ‬
‫عنصر‬
‫احتجاز‬
‫الح‬
‫رارة‬
‫فى‬
‫االعتبار‬
‫وقيم‬
‫سعة‬
‫حمل‬
‫التيار‬
‫الواردة‬
‫الجداول‬
‫المرفقة‬
‫معطاه‬
‫على‬
‫أساس‬
‫أن‬
‫الكابل‬
‫مالم‬
‫س‬
‫لمادة‬
‫عازلة‬
‫للحرارة‬
‫من‬
‫جهة‬
‫واحدة‬
‫أما‬
‫اذا‬
‫كان‬
‫الكابل‬
‫محاطا‬
‫بهذه‬
‫المادة‬
‫العازلة‬
‫للحرارة‬
‫فإن‬
‫المعامل‬
Ci
‫المستخدم‬
Ci=0.5
‫الكلى‬ ‫التصحيح‬ ‫معامل‬ ‫حساب‬
:
calculation of total correction factors
‫ت‬ ‫معا‬ ‫تتطلب‬ ‫التى‬ ‫الحاالت‬ ‫من‬ ‫أكثر‬ ‫أو‬ ‫لواحد‬ ‫مساره‬ ‫خالل‬ ‫يتعرض‬ ‫قد‬ ‫الكابل‬ ‫أن‬ ‫يالحظ‬
‫طبيق‬
‫اال‬ ‫فى‬ ‫األمر‬ ‫هذا‬ ‫أخذ‬ ‫يجب‬ ‫لذا‬ ‫الوقت‬ ‫نفس‬ ‫فى‬ ‫جميعها‬ ‫أو‬ ‫بعضها‬ ‫سواء‬ ‫التصحيح‬ ‫معامالت‬
‫عتبار‬
‫الكلى‬ ‫التصحيح‬ ‫معامل‬ ‫تحديد‬ ‫عند‬
C.F
‫ما‬ ‫كابل‬ ‫على‬ ‫تطبيقه‬ ‫ينبغى‬ ‫الذى‬
‫رقم‬ ‫جدول‬
(
3
)
‫المصرى‬ ‫للكود‬ ‫طبقا‬
‫رقم‬ ‫جدول‬
(
4
)
‫المصرى‬ ‫للكود‬ ‫طبقا‬
6.5 calculation of current carrying capacity
*
‫الخامسة‬‫الخطوة‬
:
‫للكابل‬‫ية‬‫ر‬‫التيا‬‫السعة‬‫حساب‬
Iz
‫للمواص‬ ‫طبقا‬ ‫مصهر‬
‫فات‬
IEC269-3
‫عالى‬ ‫أداء‬ ‫ذو‬
Ci= 0.5
Cg= 0.7
Ca= 0.97
30 A
‫كهربائى‬ ‫حمل‬
‫مثال‬
(
1
)
‫التالية‬‫المعادلة‬ ‫تطبيق‬‫يتم‬ ‫المبين‬‫الشكل‬‫فى‬‫المبين‬‫للكابل‬‫التيارية‬‫السعة‬‫قيمة‬‫لحساب‬
:
F
C
In
Iz
.

‫للمصهر‬‫التصحيح‬‫معامل‬‫فإن‬‫عالى‬‫داء‬‫ا‬‫ذو‬‫المستخدم‬‫المصهر‬‫ن‬‫ا‬ ‫حيث‬
Cf = 1
‫التصحيح‬‫معامل‬ ‫ويكون‬
Ca"
"
‫يتعرض‬‫الذى‬‫الكابل‬‫من‬‫للجزء‬
‫للتجميع‬‫التصحيح‬‫ومعامل‬‫المحيط‬‫الوسط‬ ‫ارة‬‫ر‬‫ح‬‫لدرجة‬
Cg
‫ن‬‫ا‬‫ى‬‫ا‬‫ضربهما‬‫لحاصل‬ ً‫مساويا‬ ‫خرى‬‫ا‬‫كابالت‬‫مع‬
:
-
Cg x Ca = 0.7 x 0.97
ْ‫ويكونْمعاملْالتصحيح‬
Ci
‫للجزءْمنْالكابلْالمحاطْبعازلْحرارىْكاملْم‬
ْ‫ساويا‬
ْ‫للقيمة‬
0.5
ْ‫ويتضحْمنْهذاْأنْالمعامل‬
Ci
‫هوْأقلْمعاملْبالمقارنةْبالحالةْال‬
ْ‫تىْيتم‬
ْ‫فيهاْتطبيق‬
Cg.Ca
ْ‫لذاْفإنْمعاملْالتصحيحْالكلىْللكابلْهو‬
:
= Cf.Ci = 1 x 0.5 = 0.5
Cf
ْ‫وبذلكْفإنْالسعةْالتيارية‬
Iz
ْ‫هى‬
:
A
Iz 60
5
.
0
30


‫مثال‬
2
)
‫كالحالة‬
‫السابقة‬
‫ولكن‬
‫المصهر‬
‫المستخدم‬
‫ذو‬
‫أداء‬
‫خاص‬
(
‫بطىء‬
)
‫ومن‬
‫طراز‬
‫ينتج‬
‫طبقا‬
‫للمواصفات‬
‫الكهروميكانيكية‬
‫العالمية‬
IEC269-3
‫تتكون‬
‫فيه‬
‫معامل‬
‫التصحيح‬
‫للمصهر‬
Cf
‫هى‬
0.725
‫وتكون‬
‫قيمة‬
‫السعة‬
‫التيارية‬
Iz
‫هى‬
:
A
Ci
C
Iz
f
75
.
82
5
.
0
725
.
0
30
30





Ci= 0.5
Cg= 0.5
Ca= 0.97
30 A ‫كهربائى‬ ‫حمل‬
‫مثال‬
3
)
‫فى‬
‫هذا‬
‫المثال‬
‫فإن‬
‫معامل‬
‫التصحيح‬
‫لكل‬
‫من‬
‫درجة‬
‫ارة‬‫ر‬‫ح‬
‫الوسط‬
‫المحيط‬
Ca
‫وتجميع‬
‫الكابالت‬
Cg
‫ليصبح‬
‫حاصل‬
‫ضربها‬
‫هو‬
0.485
‫وهى‬
‫قل‬‫ا‬
‫من‬
‫قيمة‬
‫معامل‬
‫التصحيح‬
Ci
‫نتيجة‬
‫لمالصقة‬
‫الكابل‬
‫لعازل‬
‫ى‬‫ار‬‫ر‬‫ح‬
‫وقيمته‬
0.5
‫وحيث‬
‫ن‬‫ا‬
‫المصهر‬
‫المستخدم‬
‫ذا‬
‫داء‬‫ا‬
‫خاص‬
‫طبقا‬
‫للمواصفات‬
‫الكهروتقنية‬
IEC269.3
‫فإن‬
‫معامل‬
‫تصحيح‬
‫المصهر‬
Cf
‫يكون‬
‫مساويا‬
‫للقيمة‬
0.725
‫وبذلك‬
‫يصبح‬
‫معامل‬
‫التصحيح‬
‫الكلى‬
Cf
‫للكابل‬
‫مساويا‬
‫تى‬‫ال‬
:
.
x Ca x Cg
Cf =
f
C
‫هى‬‫للكابل‬‫التيارية‬‫السعة‬‫وتكون‬
:
-
A
Iz 3
.
85
485
.
0
725
.
0
30



6 . 6 Revision of some items
‫الخطوة‬
‫السادسة‬
:
‫مراجعة‬
‫بعض‬
‫البنود‬
‫التالية‬
:
1
-
‫يتم‬
‫اختيار‬
‫مساحة‬
‫مقطع‬
‫الكابل‬
‫المناسب‬
‫للسعة‬
‫التيارية‬
‫للكابل‬
‫بع‬
‫د‬
‫تطبيق‬
‫معامالت‬
‫التصحيح‬
‫وطبقا‬
‫لجداول‬
‫التحميل‬
‫المعدة‬
‫بواسطة‬
‫المصنع‬
.
2
-
‫مراجعة‬
‫هبوط‬
‫الجهد‬
:
voltage drop
‫ترتبط‬
‫قيمته‬
‫الهبوط‬
‫فى‬
‫الجهد‬
‫للموصل‬
‫بقيمة‬
‫مقاومته‬
‫والتيار‬
‫المار‬
‫فيه‬
‫ولذل‬
‫ك‬
‫فإن‬
‫جهد‬
‫الدائرة‬
‫عند‬
‫الحمل‬
‫قد‬
‫يقل‬
‫عن‬
‫المسموح‬
‫به‬
‫اذا‬
‫كانت‬
‫الموصالت‬
‫التى‬
‫تغذى‬
‫الحمل‬
‫ذات‬
‫مساحة‬
‫مقطع‬
‫صغيرة‬
.
‫وتتطلب‬
‫هذه‬
‫االشتراطات‬
‫أال‬
‫ينخفض‬
‫الجهد‬
‫عند‬
‫الحمل‬
‫الكامل‬
‫بأكثر‬
‫من‬
2.5
%
‫من‬
‫قيمته‬
‫عند‬
‫نقطة‬
‫التغذية‬
‫الرئيسية‬
‫وعلى‬
‫ذلك‬
:
‫يكون‬
‫أقصى‬
‫هبوط‬
‫فى‬
‫الجهد‬
‫مسموح‬
‫به‬
‫ال‬
‫يتعدى‬
5.5
‫فولت‬
‫فى‬
‫حالة‬
‫التغذية‬
‫بدائرة‬
‫ذات‬
‫طور‬
‫واحد‬
(single
phase)
‫على‬
‫جهد‬
220
‫فولت‬
.
‫وفى‬
‫حالة‬
‫التغذية‬
‫بدائرة‬
‫ذات‬
‫ثالثة‬
‫أطوار‬
‫على‬
‫جهد‬
‫خطى‬
380
‫فولت‬
‫فإن‬
‫أقصى‬
‫هبوط‬
‫مسموح‬
‫به‬
‫فى‬
‫جه‬
‫د‬
‫الخط‬
‫ال‬
‫يتعدى‬
9.5
‫فولت‬
.
‫حساب‬
‫هبوط‬
‫الجهد‬
:
calculation of voltage drop
‫يمكن‬
‫حساب‬
‫قيمة‬
‫هبوط‬
‫الجهد‬
‫من‬
‫العالقة‬
‫التالية‬
:
1000
L
I
mV
Vc B 


‫حيث‬
:
-
‫بالفولت‬‫الجهد‬‫هبوط‬
VC:
‫مبير‬‫بال‬‫للكابل‬‫التصميمى‬‫التيار‬
IB:
‫بالمتر‬‫الموصل‬‫و‬‫ا‬‫الكابل‬‫طول‬
L:
‫فولت‬‫بالمللى‬‫الموصل‬‫و‬‫ا‬‫الكابل‬‫فى‬‫النوعى‬ ‫الجهد‬‫هبوط‬
/
‫مبير‬‫ا‬
/
‫طولى‬‫متر‬
mV:
‫لومونيوم‬‫ال‬‫و‬‫ا‬‫النحاس‬‫من‬ ‫القطاعات‬‫لجميع‬‫بذلك‬‫الخاص‬‫الجدول‬‫ومرفق‬
‫المسموح‬ ‫القيمة‬ ‫فية‬ ‫الجهد‬ ‫هبوط‬ ‫يتعدى‬ ‫ال‬ ‫بحيث‬ ‫الموصل‬ ‫أو‬ ‫للكابل‬ ‫طول‬ ‫أقصى‬ ‫تقدير‬ ‫ويمكن‬
‫من‬ ‫بها‬
‫التاليه‬ ‫المعادلة‬ ‫واقع‬
:
-
‫للكابل‬‫طول‬ ‫قصى‬‫ا‬
=
‫به‬‫مسموح‬‫جهد‬‫هبوط‬‫قصى‬‫ا‬
x
1000
IB X mV
‫به‬‫مسموح‬‫جهد‬‫هبوط‬‫قصى‬‫ا‬‫ستعمال‬‫ا‬‫مع‬
(
5.5
‫فولت‬
)
,
‫و‬‫ا‬
(
9.5
‫فولت‬
)
‫التغذية‬‫دائره‬‫لنوع‬ ‫طبقا‬
.
‫جدولى‬
(
5
،
6
)
Tables of Voltage Drop / Ampere / meter for each cross – section : -
* For Copper Cables: - * For Aluminum
Cross section mV/A/m
4 mm²
6mm²
10mm²
16mm²
25mm²
35mm²
50mm²
70mm²
95mm²
120mm²
150mm²
185mm²
240mm²
300mm²
9.2
6.2
3.7
3.2
1.5
1.1
0.82
0.59
0.45
0.38
0.34
0.3
0.27
0.18
Cross section mV/A/m
16 mm²
25mm²
35mm²
50mm²
70mm²
95mm²
120mm²
150mm²
185mm²
240mm²
300mm²
3.9
2.5
1.8
1.3
0.93
0.69
0.56
0.48
0.4
0.34
0.3
) ‫جدول‬
(
5 ‫جدول‬
(
6
)
3
-
‫القصر‬ ‫تيار‬ ‫حساب‬
:
calculation of short circuit current
‫بغرض‬ ‫وذلك‬ ‫الكهربائية‬ ‫التركيبات‬ ‫فى‬ ‫المختلفة‬ ‫النقاط‬ ‫عند‬ ‫القصر‬ ‫تيارات‬ ‫حساب‬ ‫يجب‬
:

‫القطع‬ ‫سعة‬ ‫اختبار‬
breaking capacity
‫فصل‬ ‫اتمام‬ ‫يمكنها‬ ‫التى‬ ‫الوقاية‬ ‫لمهمات‬
‫الفصل‬ ‫أثناء‬ ‫تتأثر‬ ‫أن‬ ‫بدون‬ ‫التغذية‬
.

‫االنتقائية‬ ‫خاصية‬ ‫لتحقيق‬ ‫الالزمة‬ ‫الوقاية‬ ‫تشغيل‬ ‫تيارات‬ ‫اختبار‬
selectivity
‫لتالفى‬
‫داع‬ ‫بدون‬ ‫األحمال‬ ‫بعض‬ ‫عن‬ ‫التغذية‬ ‫فصل‬
.
‫يلى‬ ‫كما‬ ‫الثالثى‬ ‫القصر‬ ‫تيار‬ ‫حساب‬ ‫يتم‬ ‫القطع‬ ‫سعة‬ ‫اختيار‬ ‫ولغرض‬
:
Zt
U
Zt
U
c
Is n
S 05
.
1
. 

‫حيث‬
:
-
‫الثالثى‬ ‫القصر‬‫لتيار‬‫العددية‬ ‫القيمة‬
:
Is.c
‫ر‬‫للطو‬ ‫الكلية‬‫للمعاونة‬ ‫العددية‬ ‫القيمة‬
‫القصر‬‫موقع‬‫حتى‬‫التغذية‬‫مصدر‬‫من‬
:
Zt
‫حمل‬‫وجود‬‫عدم‬‫عند‬ ‫بالفولت‬ ‫المصدر‬‫اف‬‫ر‬‫ط‬‫ا‬‫عند‬‫ر‬‫الطو‬‫جهد‬
:
Us
‫حمل‬‫وجود‬ ‫حالة‬‫فى‬ ‫المصدر‬‫اف‬‫ر‬‫ط‬‫ا‬ ‫عند‬‫ر‬‫الطو‬‫جهد‬
:
Un
‫القصر‬ ‫حالة‬ ‫فى‬ ‫الكلية‬ ‫المعادلة‬ ‫حساب‬ ‫يجب‬ ‫فإنه‬ ‫بعاليه‬ ‫للمعادلة‬ ‫القصر‬ ‫تيار‬ ‫ولحساب‬
Zt
‫يلى‬ ‫كما‬
:
-
‫الكلية‬ ‫المعادلة‬ ‫تشمل‬
Zt
‫التوزي‬ ‫قضبان‬ ‫أو‬ ‫التغذية‬ ‫وكابالت‬ ‫بالمصدر‬ ‫الخاصة‬ ‫المعاوقات‬ ‫مجموع‬
‫ع‬
‫ا‬ ‫دائرة‬ ‫مكونات‬ ‫من‬ ‫لكل‬ ‫والممانعات‬ ‫المقاومات‬ ‫حسابات‬ ‫يلى‬ ‫وفيما‬ ‫والتوصيل‬ ‫القطع‬ ‫ووحدات‬
، ‫لقصر‬
‫المنخفض‬ ‫الجهد‬ ‫دائرة‬ ‫جهة‬ ‫فى‬ ‫الخطأ‬ ‫يكون‬ ‫عندما‬ ‫وذلك‬
.
‫أ‬
)
‫المتوسط‬ ‫الجهد‬ ‫ذو‬ ‫التغذية‬ ‫مصدر‬
:
‫مقاومة‬ ‫تهمل‬
Rs.c
‫التغذ‬ ‫محول‬ ‫قبل‬ ‫للمصدر‬ ‫الكائن‬ ‫المكافئة‬ ‫الممانعة‬ ‫حساب‬ ‫ويمكن‬ ‫للمصدر‬
‫ية‬
‫التالية‬ ‫المعادلة‬ ‫من‬ ‫القصر‬ ‫نقطة‬ ‫عند‬ ‫الجهد‬ ‫الى‬ ‫منسوب‬
XS.C(M.OHM)
RS.C (M.OHM)
US ( UOLTS)
S.C(K.VA)
0.633
0.095
231
250.000
0.316
0.047
231
500.000
‫ب‬
)
‫المنخفض‬ ‫الجهد‬ ‫تغذية‬ ‫محول‬
:
Transformer
‫التالية‬ ‫الصيغة‬ ‫باستعمال‬ ‫المحول‬ ‫لمعاوقة‬ ‫العددية‬ ‫القيمة‬ ‫حساب‬ ‫يمكن‬
:
c
Us
A
V
K
Us
c
Zs .
.
.
3
.
2

‫حيث‬
:
‫بالمللى‬‫المحول‬‫لمقاومة‬‫العددية‬‫القيمة‬
.
‫القصر‬‫نقطة‬‫عند‬‫الجهد‬‫الى‬‫منسوبة‬‫وم‬‫ا‬
:
Zs.c
‫القصر‬‫نقطة‬‫عند‬‫حمل‬‫وجود‬ ‫عدم‬‫حالة‬‫فى‬‫التعادل‬‫وموصل‬‫ر‬‫الطو‬‫بين‬‫الجهد‬‫فرق‬
:
Us
‫عنها‬‫ويعوض‬‫الخطا‬‫ناحية‬‫المقنن‬ ‫الجهد‬‫الى‬‫الكامل‬‫الحمل‬‫عند‬‫المحول‬‫فى‬‫الجهد‬‫هبوط‬‫نسبة‬
(
0.04
،
0.05
،
0.06
:)
-
:
Us.c
‫مبير‬‫ا‬‫فولت‬‫بالكيلو‬‫طوار‬‫ال‬‫ثالثى‬‫المحول‬‫قدرة‬
:
-
K.V.A:
‫والجدول‬
‫التالى‬
‫استرشادى‬
‫يعطى‬
‫قيما‬
‫نة‬‫ر‬‫للمقا‬
‫والممانعة‬
‫للمحولت‬
‫المختلفة‬
‫القدرة‬
‫منسوبة‬
‫لجهة‬
‫الجهد‬
‫المنخفض‬
380/220
‫فولت‬
‫وذلك‬
‫فى‬
‫حالة‬
‫عدم‬
‫ود‬‫ر‬‫و‬
‫بيانات‬
‫من‬
‫الصانع‬
(
‫جدول‬
7
)
‫يوضح‬
‫قيم‬
‫الممانعة‬
‫والمقاومة‬
‫للمحولت‬
‫ويجب‬
‫مالحظة‬
‫نه‬‫ا‬
‫فى‬
‫حالة‬
‫استخدام‬
‫عدد‬
‫من‬
‫المحولت‬
‫على‬
‫ى‬‫التواز‬
‫فيجب‬
‫ن‬‫ا‬
‫نقسم‬
‫قيمة‬
‫الممانعة‬
‫للمحول‬
‫الواحد‬
‫على‬
‫عدد‬
‫المحولت‬
‫للحصول‬
‫على‬
Xs.c
‫لمجموعة‬
‫المحولت‬
.
‫يمكن‬
‫حساب‬
Rsc
‫من‬
‫المعادلة‬
n
I
c
Rs
PCu 2
.
3

‫حيث‬
Pcu
:
‫بالوات‬‫النحاس‬‫فى‬‫الفقد‬
.
‫فإن‬‫السعة‬‫الكبيرة‬‫للمحولت‬‫وبالنسبة‬
Rs.c
‫إهمالها‬‫ويمكن‬ ‫صغيرة‬‫قيمة‬‫ذات‬‫تكون‬
.
‫رقم‬ ‫جدول‬
(
7
)
‫قيم‬
‫والممانعة‬‫المقاومة‬
‫للمحوالت‬‫والمعاوقة‬
‫جـ‬
)
‫الدوائر‬ ‫قواطع‬
Breakers
circuit
ْ‫يرجعْالىْكتالوجاتْالمنتجْويمكنْإهمال‬
Xs.c
ْ،
Rs.c
ْ‫فىْحالةْعدمْوجودْتفصيالت‬
.
‫اْفىْحالةْقواطعْالجهدْالمنخفضْاذاْلمْتكنْهناكْمعلوماتْمنْالم‬ْ‫وعموما‬
ْ‫نتجْيمكنْاعتبار‬
Rs.c
ْ،ْ‫مهملة‬
Xs.c
ْ‫فىْحدود‬
0.15
ْ‫مللىْأرم‬
.
‫د‬
)
‫والكابالت‬ ‫الموصالت‬
cables & conductors
ْ‫يمكنْحسابْالمقاومة‬
Rs.c
ْ‫بالمللىْأومْمنْالعالقةْالتالية‬
:
Rsc
A
L


‫حيث‬
L
،‫بالمتر‬
A
‫عند‬‫لومونيوم‬‫وال‬‫للنحاس‬‫النوعية‬‫المقاومة‬‫قيمة‬‫وتبلغ‬‫المربع‬‫بالملليمتر‬
70ْ
‫كالتالى‬‫م‬
:
= 21mm.ohm.mm2/m
cu

= 33mm.ohm.m²
AL

‫الممانعة‬
Xs.c
‫الواحد‬‫ر‬‫للطو‬‫وم‬‫ا‬‫بالمللى‬
:
-
Xs.c = 0.07x L
Xs.c = 0.15 x L
ً‫معا‬‫للموصلين‬ ‫قطاب‬‫ال‬‫حادى‬‫ا‬‫للكابل‬
.
‫من‬‫قل‬‫ال‬‫للكابالت‬‫وبالنسبة‬
25
‫مم‬
2
‫المقاومة‬‫بقيم‬‫نة‬‫ر‬‫مقا‬‫الممانعة‬‫إهمال‬‫يمكن‬
.
‫هـ‬
)
‫القضبان‬
:
Bus bars
‫المقاومة‬
Rb
‫وتكون‬
L
‫و‬ ‫بالمتر‬
A
‫المربع‬ ‫بالملليمتر‬
‫للنحاس‬ ‫النوعية‬ ‫المقاومة‬ ‫قيمة‬ ‫وتبلغ‬
21
‫مللى‬
.
‫أوم‬
.
‫مم‬
2
/
‫م‬
‫ولأللومونيوم‬
33
‫مللى‬
.
‫أوم‬
.
‫مم‬
2
/
‫م‬
‫الممانعة‬
Xb
(
‫بالمللى‬
.
‫أوم‬
= )
Xb = 0.15 x L
‫الصغير‬ ‫المقطع‬ ‫ذات‬ ‫عدا‬ ‫القضبان‬ ‫مقاومة‬ ‫إهمال‬ ً‫ا‬‫عموم‬ ‫ويمكن‬
.
6.7 Example For Calculation of Short Circuit Currents :-
‫القصر‬ ‫تيارات‬ ‫لحساب‬ ‫مثال‬ ‫يلى‬ ‫وفيما‬
[
‫رقم‬ ‫تخطيطى‬ ‫رسم‬
(
1
] )
‫أ‬
)
‫المتوسط‬ ‫الجهد‬
:
medium voltage
‫قيمة‬ ‫اهمال‬ ‫يمكن‬
R1
‫لـ‬ ‫بالنسبة‬
X1
‫قيمة‬ ‫حساب‬ ‫أردنا‬ ‫واذا‬
X1
‫المنخفض‬ ‫الجهد‬ ‫الى‬ ‫منسوبة‬
Un =
380v
‫القطر‬ ‫دائرة‬ ‫قدرة‬ ‫وباعتبار‬
500
‫م‬
.
‫ف‬
.
‫قيمة‬ ‫تكون‬ ‫أ‬
X1
‫التالى‬ ‫النحو‬ ‫على‬
:
( Us = 1.05Un )
‫ب‬
)
‫المحول‬
:
Transformer
‫اهمال‬ ‫ويمكن‬
R2
‫لقيمة‬ ‫بالنسبة‬
X2
‫القصر‬ ‫دائرة‬ ‫لجهد‬ ‫المئوية‬ ‫النسبة‬ ‫قيمة‬ ‫تكون‬
Us.c
‫هى‬
0.05
‫جدول‬ ‫من‬ ‫وذلك‬
(
7
)
‫قيمة‬ ‫تصبح‬ ‫وعندئذ‬
X2
‫يلى‬ ‫كما‬
:
X1 +X2 = 0.32 + 7.96 = 8.28m.ohm
A
L


Ohm
m
X .
96
.
7
1000
05
.
0
)
05
.
1
380
(
2
2




‫جـ‬
)
‫الرئيسية‬ ‫التوزيع‬ ‫ولوحة‬ ‫المحول‬ ‫بين‬ ‫التوصيل‬ ‫قضبان‬
:
Bus duct
‫حساب‬ ‫يمكن‬
R3
X3
‫التالى‬ ‫النحو‬ ‫على‬
:
X3 = 0.15 x 5 = 0.75 m.ohm
‫د‬
)
‫الرئيسى‬ ‫القاطع‬
:
Main circuit breaker
‫اهمال‬ ‫يمكن‬
ra
‫لـ‬ ‫بالنسبة‬
Xa
‫وتكون‬
:
Xa = 0.15m. ohm
‫هـ‬
)
‫التوزيع‬ ‫قضبان‬
:
Bus bars
Xb = 0.15 x 2 = 0.3m.ohm
‫و‬
)
‫فرعى‬ ‫قاطع‬
:
Branch circuit breaker
‫اهمال‬ ‫يمكن‬
Rs.c
‫لـ‬ ‫بالنسبة‬
Xs.c
‫وتكون‬
Xs.c = 0.15m.ohm
‫فرعي‬ ‫قواطع‬ ‫وثالث‬ ‫الرئيسى‬ ‫القاطع‬ ‫شاملة‬ ‫بأكملها‬ ‫التوزيع‬ ‫لوحة‬ ‫وممانعة‬ ‫مقاومة‬ ‫تكون‬ ‫وبذلك‬
‫ة‬
‫كما‬
‫يلى‬
:
‫مهملة‬ ‫كمية‬
=
R4
X4 = 0.6m.ohm
‫ز‬
)
‫األلومونيوم‬ ‫التغذية‬ ‫كابل‬
Aluminum cable
R5
X5 = 0.07 x 50 = 3.5m.ohm
A
L
R


ohm
m
X
R .
088
.
0
1200
5
21
3 

A
L

 ohm
m.
11
150
50
33



‫ويكون‬‫الرسم‬‫فى‬‫اليها‬‫المشار‬‫المختلفة‬‫النقاط‬‫عند‬‫القصر‬ ‫ات‬‫ر‬‫تيا‬‫حساب‬‫ويمكن‬
‫ا‬
)
‫النقطة‬‫عند‬ ‫القصر‬‫تيار‬
(a)
R1 + R2 = negligibly small
X1 + X2 = 8.28m.ohm
kA
a
c
Is 28
82
.
27
28
.
8
05
.
1
220
)
(
. 



‫ب‬
)
‫النقطة‬‫عند‬‫القصر‬‫تيار‬
(b)
R1 + R2 + R3 = negligibly small
X1 + X2 + X3 = 0.32 + 7.96 + 0.75 = 9.03m.ohm
kA
26
51
.
25
03
.
9
05
.
1
220




‫ج‬
)
‫النقطة‬‫عند‬‫القصر‬ ‫تيار‬
(c)
R1 + R2 + R3 + R4 = negligibly small
X1 + X2 + X3 + X4 = 9.03 + 0.6 = 9.63m.ohm
A
k
C
c
Is .
24
921
.
23
63
.
9
05
.
1
220
)
(
. 



Isc(b)
‫د‬
)
‫النقطة‬‫عند‬ ‫القصر‬‫تيار‬
(d)
R1 + R2 + R3 + R4+ R5 = 0 + 0 + 0.088 + 0 + 11 = 11.088
X1 + X2 + X3 + X4 + X5 = 9.63 + 3.5 = 13.13 m.ohm




 2
2
X
R
Zt


 2
2
)
13
.
13
(
)
088
.
11
(
ohm
m.
19
.
17
34
.
295
4
.
172
94
.
122 


kA
17
44
.
13
19
.
17
05
.
1
220




Isc(d)
6.8 Example For Choice A Suitable Cable Cross Section Area For Load
‫مثال‬
:
‫على‬
‫اختيار‬
‫مقطع‬
‫الكابل‬
‫المناسب‬
‫ألحد‬
‫األحمال‬
‫حسب‬
‫الرسم‬
‫التخطيطى‬
‫رقم‬
(
2
)
‫محول‬
‫قدرة‬
500
k
.V.A
‫جهد‬
10500/380
volt
‫يغذى‬
‫منشأ‬
‫يبعد‬
‫عنه‬
‫بمسافة‬
250
‫متر‬
‫مطلوب‬
‫تصميم‬
‫قطاع‬
‫الكابل‬
‫المناسب‬
‫للحمل‬
‫الكهربائى‬
‫المغذى‬
‫للمنشأ‬
.
‫التالية‬ ‫لألسسس‬ ‫طبقا‬ ‫التصميم‬ ‫يتم‬
:
-
‫للكابل‬‫التيارية‬‫السعة‬
Current carrying capacity
‫الجهد‬‫هبوط‬‫قيمة‬
Voltage drop
‫المناسبة‬‫التصحيح‬‫معامالت‬
Correction factors
‫القصر‬‫ات‬‫ر‬‫تيا‬‫حسابات‬
Short circuit current
‫العوامل‬ ‫هذه‬ ‫لكل‬ ‫المناسب‬ ‫الكابل‬ ‫مقطع‬ ‫اختيار‬ ‫يتم‬ ‫ذلك‬ ‫وبعد‬
‫للكابل‬ ‫التيارية‬ ‫السعة‬
1 current carrying capacity :
760
380
3
10
500
3
3






U
power
In Ampere
‫يتم‬
‫اختبار‬
‫قطاع‬
‫الكابل‬
‫المناسب‬
‫لهذا‬
‫التيار‬
‫من‬
‫الجداول‬
‫الخاصة‬
‫بتحميل‬
‫الكابال‬
‫ت‬
‫التى‬
‫يتم‬
‫اعدادها‬
‫بواسطة‬
‫الشركات‬
‫المنتجة‬
‫ونفرض‬
‫قطاع‬
‫مناسب‬
‫وهو‬
240
mm²
‫نجد‬
‫أن‬
‫التيار‬
‫المناسب‬
‫لهذا‬
‫القطاع‬
‫فى‬
‫الجداول‬
‫هو‬
345
Ampere
‫على‬
‫أساس‬
‫أن‬
‫الكابالت‬
‫مدفونة‬
‫باألرض‬
‫ومسلحة‬
.
Cable
=
‫الحمل‬
‫الكلى‬
/
‫الحمل‬
‫الكهربائى‬
‫للكابل‬
No of cables =
*
ً‫ا‬‫مبدئي‬
‫نفترض‬
‫عدد‬
3
‫كابل‬
‫قطاع‬
(
3
x240+120 mm²)
3
2
.
2
345
760


Amper
cable
I 254
3
.
253
3
/
760
/ 


‫الجهد‬ ‫هبوط‬ ‫قيمة‬ ‫حساب‬
2.Calculation of voltage drop:
‫التالية‬ ‫بالمعادلة‬ ‫الجهد‬ ‫هبوط‬ ‫قيمة‬ ‫حساب‬ ‫يمكن‬
L
I
mV
V n
c 


‫هبوط‬
‫الجهد‬
‫النوعى‬
‫فى‬
‫الكابل‬
‫و‬‫ا‬
‫الموصل‬
‫بالمملى‬
‫فولت‬
/
‫مبير‬‫ا‬
/
‫متر‬
(
‫ج‬‫ر‬‫مد‬
‫فى‬
‫الجداول‬
‫هبوط‬
‫ال‬
‫فولت‬
)
mV :
‫التيار‬
‫التصميمى‬
‫للكابل‬
‫مبير‬‫باال‬
:
In
‫طول‬
‫الكابل‬
‫بالمتر‬
:
L
3
10
0.27x
(=
‫قطاع‬‫الكابل‬
240
‫مم‬
2
)
mV
Vc = 0.27 254
10 3

  ampere x 250 (meter)
2
.
17
 volt
380
2
.
17
=
‫الجهد‬‫هبوط‬‫قيمة‬
/
‫المستخدم‬‫الكلى‬‫الجهد‬
=
percentage of voltage drop
*
‫وهذه‬
‫النسبة‬
‫لهبوط‬
‫الجهد‬
‫تعتبر‬
‫عاليه‬
‫نسبيا‬
‫حيث‬
‫ن‬‫ا‬
‫النسبة‬
‫المسموح‬
‫بها‬
‫هى‬
:
=
2.5
%
‫قيمة‬‫ى‬‫ا‬
=
9.5
volt
*
‫وباعادة‬
‫التعويض‬
‫فى‬
‫معادلة‬
‫هبوط‬
‫الجهد‬
‫بفرض‬
‫ن‬‫ا‬
‫قصى‬‫ا‬
‫قيمة‬
‫مسموح‬
‫بها‬
‫فى‬
‫الهبوط‬
‫هى‬
9.5
‫فولت‬
‫فإننا‬
‫نحصل‬
‫من‬
‫هذه‬
‫المعادلة‬
‫على‬
‫قصى‬‫ا‬
‫تيار‬
‫تصميمى‬
‫يؤدى‬
‫الى‬
‫هبوط‬
‫جهد‬
‫مناسب‬
‫ل‬
‫يتعدى‬
‫ال‬
2.5
%
= 17.14
4.5%
=
L
mV
V
I C
n



3
10
140
250
27
.
0
10
5
.
9 3




n
I Ampere
*
‫قطاع‬ ‫الكابالت‬ ‫عدد‬ ‫حساب‬ ‫يمكن‬
240
mm²
‫جهد‬ ‫هبوط‬ ‫تعطى‬ ‫والتى‬ ‫للتيار‬ ‫الجديدة‬ ‫للقيم‬ ‫طبقا‬
‫مناسب‬
Cables
No of cables =
*
‫كابل‬ ‫لكل‬ ‫المقنن‬ ‫التيار‬
(In)
‫بعاليه‬ ‫الكابالت‬ ‫لعدد‬ ‫طبقا‬
(
6
‫كابالت‬
)
In = ***
3 – Application of correction factors :- ( ‫للكابالت‬ ‫التصحيح‬ ‫معامالت‬ ‫)تطبيق‬
a ) “ Ca “ ‫األرض‬ ‫سطح‬ ‫تحت‬ ‫مدفونة‬ ‫الكابالت‬ ‫أن‬ ‫حيث‬ ‫المحيط‬ ‫الوسط‬ ‫حرارة‬ ‫تأثير‬ ‫معامل‬
Ca = 1 (
‫المرفقة‬ ‫الجداول‬ ‫من‬
)
b ) “ Cg” grouping factor ‫الكابالت‬ ‫تجميع‬ ‫معامل‬
‫عدد‬ ‫كل‬ ‫فى‬ ‫طبقتين‬ ‫على‬ ‫الكابالت‬ ‫يتركب‬
3
‫الـ‬ ‫جداول‬ ‫فى‬ ‫وبالبحث‬ ‫كابالت‬
Cg
‫أن‬ ‫نجد‬
Cg = 0.7
*
‫للكابالت‬ ‫الكلى‬ ‫التصحيح‬ ‫معامل‬
“ Cf “
“Cf “ = Ca x Cg = 1 x0.7 = 0.7
‫يلى‬ ‫كما‬ ‫للكابل‬ ‫التيارية‬ ‫السعة‬ ‫حساب‬ ‫يمكن‬
:
ampere ***
6
4
.
5
140
760


Amp
126
6
760

In =
180
7
.
0
126



F
B
C
I
Iz
‫هى‬ ‫للكابل‬ ‫تيارية‬ ‫سعة‬ ‫أقصى‬
180
A
‫قيمته‬ ‫تيار‬ ‫تصميم‬ ‫تم‬ ‫أنه‬ ‫وبما‬
126
A
‫الواحد‬ ‫للكابل‬
‫وهما‬ ‫الشرطين‬ ‫وتحقق‬ ‫مناسبة‬ ‫القيمة‬ ‫هذه‬ ‫اذن‬
:
1 – voltage drop
2 – (Iz) (
‫للكابل‬ ‫التيارية‬ ‫السعة‬
) ‫الكابل‬ ‫فى‬ ‫بمروره‬ ‫مسموح‬ ‫تيار‬ ‫أقصى‬ ‫قيمة‬ ‫وهى‬
.
4 – Calculation of short circuit currents: - :) ‫القصر‬ ‫تيارات‬ ‫)حساب‬
‫لتيار‬ ‫المالئمة‬ ‫الكابل‬ ‫مقطع‬ ‫مساحة‬ ‫حساب‬ ‫يمكن‬ ‫ذلك‬ ‫بعد‬ ‫ثم‬ ، ‫القصر‬ ‫تيار‬ ‫حساب‬ ‫طريقة‬ ‫يلى‬ ‫وفيما‬
‫القصر‬
‫اآلتى‬ ‫نجد‬ ‫السابق‬ ‫التوضيحى‬ ‫الرسم‬ ‫الى‬ ‫وبالرجوع‬
:
-
‫المتوسط‬ ‫الجهد‬
:
-
medium voltage
a)
‫قيمة‬ ‫اهمال‬ ‫يمكن‬
R1
‫لـ‬ ‫بالنسبة‬
X1
‫المنخفض‬ ‫الجهد‬ ‫الى‬ ‫منسوبة‬ ‫قيمة‬ ‫حساب‬ ‫وعند‬
Un = 380
‫قدرة‬ ‫وباعتبار‬
‫القصر‬ ‫دائرة‬
500
‫م‬
.
‫ف‬
.
‫قيمة‬ ‫تكون‬ ‫أ‬
X1
‫يلى‬ ‫كما‬
=0.32 m.ohm
X1 =
‫المحول‬
:
-
b ) Transformer
‫اهمال‬ ‫يمكن‬
R2
‫لقيمة‬ ‫بالنسبة‬
X2
‫القصر‬ ‫دائرة‬ ‫لجهد‬ ‫المئوية‬ ‫النسبة‬ ‫قيمة‬ ‫وتكون‬
U.S.C
‫هى‬
5
%
m.ohm
X2 =
X1 + X2 = 15.92 + 0.32 = 16.24 m.ohm
  92
.
15
500
05
.
0
05
.
1
380
2



3
2
10
500
.
)
05
.
1
380
(


vA
k
C ) Low voltage cable : ‫للمنشا‬‫يع‬‫ز‬‫التو‬ ‫ولوحة‬‫المحول‬‫بين‬‫الواصلة‬‫المنخفض‬‫الجهد‬‫كابالت‬
  ohm
m
mm
m
A
L
.
22
87
.
21
340
250
21
2





‫المصرى‬‫للكود‬ ‫طبقا‬‫ى‬‫التواز‬‫على‬‫الموصلة‬‫الكابالت‬‫عدد‬‫على‬‫الناتجة‬‫المقاومة‬‫قسمة‬‫يتم‬ ‫حيث‬
66
.
3
6
22

Xs.c = 0.07 x 250 (m) = 17.5 m.ohm
D ) Main circuit breaker ‫المنخفض‬‫للجهد‬‫التوزيع‬‫للوحة‬‫ئيسى‬‫ر‬‫ال‬ ‫القاطع‬
‫اهمال‬‫يمكن‬
Ra
‫ل‬‫بالنسبة‬
Xa
Xa = 0.15m.oh
E) Bus bars: ‫يع‬‫ز‬‫التو‬‫قضبان‬
‫اهمال‬‫يمكن‬
Rb
‫ل‬‫بالنسبة‬
Xb
‫ات‬‫ر‬‫البا‬‫طول‬‫بفرض‬
3
m
Xb = 0.15 x 3 = 0.45 m.ohm
* Short circuit impendence:-
Zt =    
  





2
3
2
1
2
2
1 ...
... R
R
R
X
X
=
   2
2
45
.
0
15
.
0
5
.
17
24
.
16
66
.
3 



5
.
34
1192
1179
39
.
13 


KA
Zt
7
5
.
34
231
05
.
1
220



Is.c = 7K.A ‫عند‬
‫لوحة‬
‫التوزيع‬
‫ئيسية‬‫ر‬‫ال‬
‫للمبنى‬
R/6cable = m.ohm
=
m.ohm
‫قيمة‬ ‫وبتطبيق‬
current
S.c
‫التالية‬ ‫المعادلة‬ ‫فى‬
90º
‫عند‬
q = 8.6 x Is.c
Where
q = cross section area in mm²
t = time in sec .
1 sec ‫بـ‬ ‫الزمن‬ ‫عن‬ ‫وبالتعويض‬
Q = 8.6x 7 = 60.2 ~ 61 mm²
‫هو‬ ‫القصر‬ ‫لتيار‬ ‫المناسب‬ ‫الكابل‬ ‫قطاع‬ ‫يكون‬ ‫وبذلك‬
70
mm²
‫النتيجة‬ ‫لهذه‬ ‫قياسى‬ ‫مقطع‬ ‫أقرب‬ ‫وهو‬
(
‫بين‬ ‫للعالقة‬ ‫بيانى‬ ‫رسم‬ ‫مرفق‬
t,q,Is.c
)
‫وال‬ ‫التيارية‬ ‫السعة‬ ‫يالئم‬ ‫اختياره‬ ‫تم‬ ‫الذى‬ ‫الكابل‬ ‫قطاع‬ ‫أن‬ ‫يتضح‬ ‫سبق‬ ‫ما‬ ‫كل‬ ‫على‬ ‫وبناءا‬
‫الجهد‬ ‫هبوط‬
‫وهو‬
240
mm²
‫القصر‬ ‫تيارات‬ ‫لتحمل‬ ‫أيضا‬ ‫مناسب‬
‫عدد‬ ‫اختيار‬ ‫يتم‬
6
‫قطاع‬ ‫كابالت‬
120mm²
+
240
×
3
‫بعاليه‬ ‫المنشأ‬ ‫لتغذية‬ ‫منخفض‬ ‫جهد‬
‫رقم‬ ‫شكل‬
(
8
)
Cross
section area
q
7.1 general precautions for cable installations
1
-
‫الكابالت‬‫تركيب‬‫فى‬‫عامة‬‫احتياطات‬

‫يجب‬
‫اعاة‬‫ر‬‫م‬
‫تى‬
‫آ‬
‫ال‬
‫فى‬
‫تركيب‬
‫الكابالت‬
‫بصفة‬
‫عامة‬
:
-

‫يجب‬
‫ن‬‫ا‬
‫اعى‬‫ر‬‫ي‬
‫ن‬‫ا‬
‫تكون‬
‫لوان‬‫ا‬
‫كل‬
‫الكابالت‬
‫موحدة‬
‫لكل‬
‫طور‬
“phase”
‫ولخط‬
‫التعادل‬
Neutral
‫ولخط‬
‫رضى‬‫ال‬
Earth
.

‫يجب‬
‫فحص‬
‫جميع‬
‫الكابالت‬
‫من‬
‫حيث‬
‫النوع‬
‫والجودة‬
‫والمقطع‬
‫واختبار‬
‫درجة‬
‫العزل‬
‫فى‬
‫الموقع‬
‫قبل‬
‫التركيب‬
،
‫ويمكن‬
‫ال‬
‫تفاء‬‫ك‬
‫بشهادات‬
‫اختبار‬
‫العزل‬
‫فى‬
‫المصنع‬
‫مع‬
‫اعاة‬‫ر‬‫م‬
‫كد‬‫التا‬
‫من‬
‫عدم‬
‫تلفها‬
‫ثناء‬‫ا‬
‫النقل‬
‫و‬‫ا‬
‫التخزين‬
.

‫اعى‬‫ر‬‫ي‬
‫عدم‬
‫تركيب‬
‫الكابالت‬
‫الخاصة‬
‫بتركيبات‬
‫باإلنارة‬
‫و‬‫ا‬
‫القوى‬
‫التى‬
‫تغذى‬
‫من‬
‫جهود‬
‫مختلفة‬
(
‫خفيف‬
–
‫منخف‬
‫ض‬
–
‫متوسط‬
)
‫فى‬
‫نفس‬
‫المواسير‬
‫و‬‫ا‬
‫ى‬‫المجار‬
‫ويجب‬
‫ن‬‫ا‬
‫تكون‬
‫توصيالت‬
‫كل‬
‫جهد‬
‫مستقلة‬
‫بمواسيرها‬
‫وعلب‬
‫إتصالها‬
.

‫اعى‬‫ر‬‫ي‬
‫عند‬
‫استخدام‬
‫المواسير‬
‫الصلب‬
‫وفى‬
‫حالة‬
‫التيار‬
‫المتردد‬
‫تركيب‬
‫موصل‬
‫الطور‬
‫وموصل‬
‫التعادل‬
‫فى‬
‫حالة‬
‫ال‬
single phase
‫وموصالت‬
‫طوار‬‫ال‬
‫وموصل‬
‫التعادل‬
‫فى‬
‫حالة‬
‫ال‬
(
3
-phase)
‫داخل‬
‫ماسورة‬
‫واحدة‬
‫ول‬
‫ينطبق‬
‫هذا‬
‫فى‬
‫حالت‬
‫المواسير‬
‫البالستيك‬
.

‫اعى‬‫ر‬‫ي‬
‫فى‬
‫توصيل‬
‫مخارج‬
‫وحدات‬
‫اإلضاءة‬
‫وما‬
‫يماثلها‬
‫والتى‬
‫تغذى‬
‫من‬
‫حد‬‫ا‬
‫طوار‬‫ا‬
‫التيار‬
‫وخط‬
‫التعادل‬
‫ن‬‫ا‬
‫يتصل‬
‫خط‬
‫التعادل‬
‫مباشرة‬
‫بوحدة‬
‫اإلضاءة‬
‫ويتصل‬
‫سلك‬
‫الطور‬
‫بها‬
‫عن‬
‫طريق‬
‫المفتاح‬
.

‫يجب‬
‫ن‬‫ا‬
‫تنتهى‬
‫جميع‬
‫اف‬‫ر‬‫ط‬‫ا‬
‫الكابالت‬
‫التى‬
‫يزيد‬
‫مقطعها‬
‫عن‬
3
‫مم‬
2
(
‫بالكوس‬
)
‫الخاص‬
‫بتوصيلها‬
(
‫مان‬‫لال‬
)
‫جهزة‬‫بال‬
.

‫يجب‬
‫ن‬‫ا‬
‫تركب‬
‫دوائر‬
‫إنارة‬
‫ء‬‫ى‬‫الطوار‬
‫فى‬
‫ات‬‫ر‬‫مسا‬
‫مستقلة‬
‫عن‬
‫ات‬‫ر‬‫مسا‬
‫دوائر‬
‫اإلنارة‬
‫العادية‬
.

‫يجب‬
‫ل‬‫ا‬
‫يقل‬
‫قطاع‬
‫موصالت‬
‫خطوط‬
‫القوى‬
‫عن‬
3
‫مم‬
2
.

‫يجب‬
‫ن‬‫ا‬
‫تكون‬
‫سالك‬‫ال‬
‫و‬‫ا‬
‫الكابالت‬
‫المستعملة‬
‫بدون‬
‫وصالت‬
‫بين‬
‫ى‬‫ا‬
‫مخرجين‬
‫و‬‫ا‬
‫فيما‬
‫بين‬
‫المخرج‬
‫وصندوق‬
‫اإلتصال‬
‫وي‬
‫حظر‬
‫عمل‬
‫وصالت‬
‫للكابالت‬
‫سالك‬‫وال‬
‫ال‬
‫فى‬
‫صناديق‬
‫اإلتصال‬
.
2
-
‫األرضية‬ ‫الكابالت‬ ‫تركيب‬ ‫إحتياطات‬

‫يفضل‬
‫تركيب‬
‫الكابالت‬
‫رضية‬‫ال‬
‫بطريقة‬
‫الدفن‬
‫المباشر‬
‫فى‬
‫رض‬‫ال‬
‫اعى‬‫ر‬‫وت‬
‫القواعد‬
‫الت‬
‫الية‬
‫عند‬
‫التركيب‬
:

‫تمديد‬
‫الكابالت‬
‫رضية‬‫ال‬
‫فى‬
‫اتها‬‫ر‬‫مسا‬
‫تحت‬
‫الساحات‬
‫المرصوفة‬
‫و‬‫ا‬
‫تقاطع‬
‫الطرق‬
‫داخل‬
‫مواس‬
‫ير‬
‫بالستيك‬
‫من‬
‫النوع‬
‫الثقيل‬
‫و‬‫ا‬
‫مواسير‬
‫صلب‬
‫يتم‬
‫حمايتها‬
‫جيدا‬
‫ضد‬
‫الصدا‬
.

‫تركيب‬
‫كابالت‬
‫الجهد‬
‫المنخفض‬
‫داخل‬
(
‫نشات‬‫ر‬‫ت‬
)
‫بعمق‬
‫ل‬
‫يقل‬
‫عن‬
80
‫سم‬
‫ما‬‫ا‬
‫كابالت‬
‫الجهد‬
‫المتوسط‬
‫فتركب‬
‫على‬
‫عمق‬
‫ل‬
‫يقل‬
‫عن‬
1
‫متر‬
‫من‬
‫منسوب‬
‫سطح‬
‫رض‬‫ال‬
.

‫إذا‬
‫إقتضت‬
‫رة‬‫و‬‫الضر‬
‫تركيب‬
‫الكابالت‬
‫فى‬
‫طبقات‬
‫ثر‬‫ك‬‫ا‬
‫من‬
‫طبقة‬
‫واحدة‬
‫فى‬
‫ات‬‫ر‬‫مسا‬
‫متقاطع‬
‫ة‬
‫يتم‬
‫الفصل‬
‫بين‬
‫الطبقات‬
‫المختلفة‬
‫و‬‫ا‬
‫الكابالت‬
‫المتقاطعة‬
‫بطبقة‬
‫رملية‬
‫بسمك‬
‫ل‬
‫يقل‬
‫عن‬
10
‫سم‬
‫وفى‬
‫هذه‬
‫الحالة‬
‫يتم‬
‫تركيب‬
‫كابالت‬
‫الجهد‬
‫المتوسط‬
‫فى‬
‫الطبقات‬
‫السفلية‬
‫على‬
‫ل‬‫ا‬
‫يقل‬
‫منسوب‬
‫على‬‫ا‬
‫طبق‬
‫ة‬
‫عن‬
60
‫سم‬
‫تحت‬
‫منسوب‬
‫رض‬‫ال‬
‫الطبيعية‬
.

‫يجهز‬
‫قاع‬
‫الخندق‬
‫قبل‬
‫رمى‬
‫الكابالت‬
‫بطبقة‬
‫من‬
‫الرمل‬
‫الناعم‬
‫بسمك‬
10
‫سم‬
‫ثم‬
‫تمدد‬
‫الكابالت‬
‫وتغطى‬
‫بطبقة‬
‫خرى‬‫ا‬
‫من‬
‫الرمل‬
‫الناعم‬
‫بسمك‬
10
‫سم‬
‫وتوضع‬
‫بعد‬
‫ذلك‬
‫بالطات‬
‫خرسانية‬
‫سمك‬
5
‫سم‬
‫فوق‬
‫هذه‬
‫الطبقة‬
‫الرملية‬
‫وبطول‬
‫مسار‬
‫الكابل‬
‫ثم‬
‫يردم‬
‫الخندق‬
‫ويدك‬
‫بعد‬
‫وضع‬
‫شريط‬
‫تحذير‬
‫صفر‬‫ا‬
‫توب‬‫مك‬
‫عليه‬
‫نوع‬
‫الكابل‬
‫بطول‬
‫المسار‬
‫على‬
‫عمق‬
30
‫سم‬
‫من‬
‫منسوب‬
‫رض‬‫ال‬
‫الطبيعية‬
‫كالشكل‬
‫رقم‬
(
24
)
.
‫ال‬ ‫بين‬ ‫الفاصلة‬ ‫المسافات‬ ‫على‬ ‫المحافظة‬ ‫واحد‬ ‫مسار‬ ‫فى‬ ‫كابل‬ ‫من‬ ‫أكثر‬ ‫تمديد‬ ‫عند‬ ‫يراعى‬
‫على‬ ‫كابالت‬
‫المصرى‬ ‫للكود‬ ‫طبقا‬ ‫التالى‬ ‫النحو‬
:
-
‫م‬
‫الكابالت‬‫نوع‬
‫الفاصلة‬‫المسافة‬‫مقدار‬
1
‫كابل‬
‫جهد‬
‫منخفض‬
‫بجانب‬
‫كابل‬
‫تليفونات‬
30
‫سم‬
‫على‬
‫قل‬‫ال‬
2
‫كابل‬
‫منخفض‬
‫بجانب‬
‫كابل‬
‫تحكم‬
(
‫كنترول‬
)
‫بدون‬
‫مسافة‬
‫فاصلة‬
3
‫كابل‬
‫تحكم‬
‫بجانب‬
‫كابل‬
‫تحكم‬
‫بدون‬
‫مسافة‬
‫فاصلة‬
4
‫كابل‬
‫جهد‬
‫منخفض‬
‫بجانب‬
‫كابل‬
‫جهد‬
‫منخفض‬
‫قطر‬
‫الكابل‬
‫وبحد‬
‫دنى‬‫ا‬
1
‫سم‬
‫ونستعمل‬
‫فواصل‬
‫بين‬
‫الكابالت‬
‫كل‬
1
-
1.5
‫متر‬
5
‫كابل‬
‫جهد‬
‫منخفض‬
‫بجانب‬
‫كابل‬
‫جهد‬
‫متوسط‬
15
‫سم‬
‫ويفصل‬
‫بينهما‬
‫بقوالب‬
‫توضع‬
ً‫سيا‬‫ا‬‫ر‬
‫على‬
‫جانبها‬
6
‫كابل‬
‫جهد‬
‫متوسط‬
‫بجانب‬
‫كابل‬
‫جهد‬
‫متوسط‬
‫اآلتى‬ ‫يراعى‬ ‫األرضية‬ ‫الكابالت‬ ‫لمرور‬ ‫المواسير‬ ‫استخدام‬ ‫عند‬
:
‫أ‬
-
‫سمك‬ ‫فرشة‬ ‫من‬ ‫مكونة‬ ‫رملية‬ ‫طبقة‬ ‫فى‬ ‫المواسير‬ ‫تدفن‬
10
‫السمك‬ ‫بنفس‬ ‫وغطاء‬ ‫سم‬
‫ب‬
-
‫وعم‬ ‫المواسير‬ ‫اتجاه‬ ‫تغيير‬ ‫عند‬ ‫تفتيش‬ ‫بغرف‬ ‫المسار‬ ‫ويزود‬ ‫فقط‬ ‫مستقيمة‬ ‫مسارات‬ ‫فى‬ ‫المواسير‬ ‫تركب‬
ً‫ا‬‫وم‬
‫كل‬ ‫التفتيش‬ ‫غرف‬ ‫تكون‬
30
‫األقل‬ ‫على‬ ‫متر‬
.
‫جـ‬
-
‫قطر‬ ‫مجلفن‬ ‫شد‬ ‫بسلك‬ ‫المواسير‬ ‫تزود‬
3
‫الى‬ ‫الماسورة‬ ‫طرفى‬ ‫خارج‬ ‫يمتد‬ ‫مم‬
50
‫األقل‬ ‫على‬ ‫سم‬
:
‫د‬
-
‫كابالت‬ ‫أى‬ ‫سحب‬ ‫قبل‬ ‫الداخل‬ ‫من‬ ‫بعناية‬ ‫المواسير‬ ‫تنظيف‬
.
*
‫تركيب‬
‫الكابالت‬
‫األرضية‬
‫المسلحة‬
‫فى‬
‫األرض‬
‫بدون‬
‫مواسير‬
:
‫أ‬
-
‫يراعى‬
‫عند‬
‫تركيب‬
‫الكابالت‬
‫فى‬
‫األرض‬
‫التحقق‬
‫من‬
‫أن‬
‫التربة‬
‫ال‬
‫تحتوى‬
‫على‬
‫أمالح‬
‫أو‬
‫مواد‬
‫كيماوية‬
‫تسبب‬
‫تآكل‬
‫الطبقات‬
‫الخارجية‬
‫للكابل‬
.
‫ب‬
-
‫واذا‬
‫كانت‬
‫التربة‬
‫تحتوى‬
‫على‬
‫أمالح‬
‫أو‬
‫مواد‬
‫كيماوية‬
‫يراعى‬
‫استعمال‬
‫كابالت‬
‫مغ‬
‫لفة‬
‫بالبالستيك‬
‫المقاوم‬
‫لعوامل‬
‫التآكل‬
.
*
‫تركيب‬
‫الكابالت‬
‫األرضية‬
‫المسلحة‬
‫داخل‬
‫مواسير‬
‫حديد‬
‫أو‬
‫فخار‬
‫أو‬
‫أسمنت‬
‫تحت‬
‫األر‬
‫ض‬
:
‫أ‬
-
‫ال‬
‫يركب‬
‫أكثر‬
‫من‬
‫كابل‬
‫واحد‬
‫داخل‬
‫ماسورة‬
‫واحدة‬
.
‫ب‬
-
‫يكون‬
‫القطر‬
‫الداخلى‬
‫للماسورة‬
‫أكبر‬
‫من‬
‫القطر‬
‫الخارجى‬
‫للكابل‬
‫بما‬
‫ال‬
‫يقل‬
‫عن‬
4
‫سم‬
.
‫جـ‬
-
‫بعد‬
‫االنتهاء‬
‫من‬
‫تركيب‬
‫المواسير‬
‫والردم‬
‫عليها‬
‫تسحب‬
‫الكابالت‬
‫داخل‬
‫المواسير‬
‫بواسطة‬
‫شدادات‬
‫من‬
‫الصلب‬
‫مع‬
‫العناية‬
‫التامة‬
‫بعدم‬
‫تعريض‬
‫الكابل‬
‫إلجهادات‬
‫ناتجة‬
‫من‬
‫قو‬
‫ة‬
‫شد‬
‫أو‬
‫ثنى‬
‫زائدة‬
‫قد‬
‫تؤثر‬
‫على‬
‫العزل‬
‫أو‬
‫على‬
‫الطبقات‬
‫الواقية‬
‫ويحسن‬
‫تغطية‬
‫السطح‬
‫الخارجى‬
‫للكابل‬
‫بمسحوق‬
‫بودرة‬
‫التلك‬
‫ليسهل‬
‫سحبه‬
‫داخل‬
‫المواسير‬
.
7-3 colour code ‫ن‬
‫ظام‬
‫لوان‬‫اال‬
‫لتمييز‬
‫قطاب‬‫اال‬
:
‫يجب‬
‫تمييز‬
‫الكابالت‬
‫نة‬‫ر‬‫الم‬
‫ذات‬
‫الموصل‬
‫الواحد‬
‫وكذا‬
‫جميع‬
‫موصالت‬
‫الكابالت‬
‫غير‬
‫نة‬‫ر‬‫الم‬
‫سواء‬
‫كانت‬
‫مزدوجة‬
‫و‬‫ا‬
‫متعددة‬
‫الموصالت‬
‫المستخدمة‬
‫فى‬
‫التوصيالت‬
‫الكهربائية‬
‫الثابتة‬
‫وذلك‬
‫على‬
‫امتداد‬
‫طولها‬
‫و‬‫ا‬
‫عند‬
‫نهايتها‬
‫عل‬
‫ى‬
‫قل‬‫ال‬
‫باستعمال‬
‫طريقة‬
‫مناسبة‬
‫كما‬
‫يلى‬
:
1
–
‫استخدام‬
‫لوان‬‫ا‬
‫موصالت‬
‫الكابالت‬
‫لة‬‫و‬‫المعز‬
‫بالكاوتشوك‬
‫لة‬‫و‬‫والمعز‬
‫بالبالستيك‬
‫طبقا‬
‫للجدول‬
‫رقم‬
(
9
)
‫و‬‫ا‬
‫باستخدام‬
‫ائط‬‫ر‬‫ش‬
‫و‬‫ا‬
‫جلب‬
‫و‬‫ا‬
‫اص‬‫ر‬‫ق‬‫ا‬
‫عند‬
‫النهايات‬
‫لوان‬‫بال‬
‫المناسبة‬
‫ة‬‫ر‬‫المذكو‬
‫بالجدول‬
.
2
-
‫ترقيم‬
‫موصالت‬
‫الكابالت‬
‫المسلحة‬
‫لة‬‫و‬‫والمعز‬
‫بالبالستيك‬
(P.V.C)
‫كبديل‬
‫للطريقة‬
‫المبينة‬
‫فى‬
‫الفقرة‬
(
1
)
‫ويشترط‬
‫تخصيص‬
‫رقام‬‫ال‬
(
1
،
2
،
3
)
‫لموصالت‬
‫طوار‬‫ال‬
‫الثالثة‬
‫قم‬‫ر‬‫و‬
‫صفر‬
‫لموصل‬
‫التعادل‬
‫قم‬‫ر‬‫و‬
(
4
)
‫للموصل‬
‫ذو‬
‫الغرض‬
‫الخاص‬
.
‫رقم‬‫جدول‬
(
9
)
‫الكابالت‬‫موصالت‬‫لتمييز‬‫المستخدمة‬ ‫لوان‬‫ال‬‫يوضح‬
‫ا‬
‫الثابتة‬‫الكهربائية‬‫التركيبات‬‫فى‬ ‫لمستخدمة‬

More Related Content

Featured

How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024Albert Qian
 
Social Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie InsightsSocial Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie InsightsKurio // The Social Media Age(ncy)
 
Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024Search Engine Journal
 
5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summary5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summarySpeakerHub
 
ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd Clark Boyd
 
Getting into the tech field. what next
Getting into the tech field. what next Getting into the tech field. what next
Getting into the tech field. what next Tessa Mero
 
Google's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search IntentGoogle's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search IntentLily Ray
 
Time Management & Productivity - Best Practices
Time Management & Productivity -  Best PracticesTime Management & Productivity -  Best Practices
Time Management & Productivity - Best PracticesVit Horky
 
The six step guide to practical project management
The six step guide to practical project managementThe six step guide to practical project management
The six step guide to practical project managementMindGenius
 
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...RachelPearson36
 
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...Applitools
 
12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at Work12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at WorkGetSmarter
 
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...DevGAMM Conference
 
Barbie - Brand Strategy Presentation
Barbie - Brand Strategy PresentationBarbie - Brand Strategy Presentation
Barbie - Brand Strategy PresentationErica Santiago
 
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them wellGood Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them wellSaba Software
 
Introduction to C Programming Language
Introduction to C Programming LanguageIntroduction to C Programming Language
Introduction to C Programming LanguageSimplilearn
 

Featured (20)

How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024How to Prepare For a Successful Job Search for 2024
How to Prepare For a Successful Job Search for 2024
 
Social Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie InsightsSocial Media Marketing Trends 2024 // The Global Indie Insights
Social Media Marketing Trends 2024 // The Global Indie Insights
 
Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024Trends In Paid Search: Navigating The Digital Landscape In 2024
Trends In Paid Search: Navigating The Digital Landscape In 2024
 
5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summary5 Public speaking tips from TED - Visualized summary
5 Public speaking tips from TED - Visualized summary
 
ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd ChatGPT and the Future of Work - Clark Boyd
ChatGPT and the Future of Work - Clark Boyd
 
Getting into the tech field. what next
Getting into the tech field. what next Getting into the tech field. what next
Getting into the tech field. what next
 
Google's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search IntentGoogle's Just Not That Into You: Understanding Core Updates & Search Intent
Google's Just Not That Into You: Understanding Core Updates & Search Intent
 
How to have difficult conversations
How to have difficult conversations How to have difficult conversations
How to have difficult conversations
 
Introduction to Data Science
Introduction to Data ScienceIntroduction to Data Science
Introduction to Data Science
 
Time Management & Productivity - Best Practices
Time Management & Productivity -  Best PracticesTime Management & Productivity -  Best Practices
Time Management & Productivity - Best Practices
 
The six step guide to practical project management
The six step guide to practical project managementThe six step guide to practical project management
The six step guide to practical project management
 
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
 
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
Unlocking the Power of ChatGPT and AI in Testing - A Real-World Look, present...
 
12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at Work12 Ways to Increase Your Influence at Work
12 Ways to Increase Your Influence at Work
 
ChatGPT webinar slides
ChatGPT webinar slidesChatGPT webinar slides
ChatGPT webinar slides
 
More than Just Lines on a Map: Best Practices for U.S Bike Routes
More than Just Lines on a Map: Best Practices for U.S Bike RoutesMore than Just Lines on a Map: Best Practices for U.S Bike Routes
More than Just Lines on a Map: Best Practices for U.S Bike Routes
 
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
Ride the Storm: Navigating Through Unstable Periods / Katerina Rudko (Belka G...
 
Barbie - Brand Strategy Presentation
Barbie - Brand Strategy PresentationBarbie - Brand Strategy Presentation
Barbie - Brand Strategy Presentation
 
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them wellGood Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
 
Introduction to C Programming Language
Introduction to C Programming LanguageIntroduction to C Programming Language
Introduction to C Programming Language
 

CABLES.ppt

  • 1.
  • 2. 1 – Definition of Cables & Conductors ‫والموصالت‬‫الكابالت‬‫يف‬‫ر‬‫تع‬ : ‫أحادى‬ ‫موصل‬ ‫على‬ ‫الكابل‬ ‫يحتوى‬ ( single conductor ) ‫أكثر‬ ‫أو‬ ‫التوصيل‬ ‫أحادية‬ ‫األسالك‬ ‫من‬ ‫مجموعة‬ ‫هو‬ ‫والموصل‬ 2 – Cable Classifications ‫ـالت‬‫ـ‬‫ـ‬‫ـ‬‫ب‬‫الكا‬‫ـواع‬‫ـ‬‫ـ‬‫ـ‬‫ن‬‫ا‬ : 2. 1 Low Voltage Cables (0.6/1-1.2)k.v ‫المنخفض‬ ‫الجهد‬‫كابالت‬ : ( ‫المحلى‬ ‫لالنتاج‬ ‫طبقا‬ )
  • 3. * ‫الـ‬ ‫بمادة‬ ‫معزولة‬ ‫كابالت‬ ( PVC : ) - Single core cables with solid or stranded capper conductors and PVC insulated 1 - ‫موصالت‬ ‫ذات‬ ‫القطب‬ ‫أحادية‬ ‫نحاس‬ ‫كابالت‬ ‫بمادة‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫أو‬ ‫مصمتة‬ ‫الـ‬ PVC ‫رقم‬ ‫شكل‬ ( 1 ) Single core cables with flexible copper conductors and PVC insulated 2 - ‫مرنة‬ ‫نحاس‬ ‫موصالت‬ ‫ذو‬ ‫القطب‬ ‫أحادى‬ ‫كابل‬ ( ‫شعر‬ ) ‫الـ‬ ‫بمادة‬ ‫ومعزولة‬ PVC ‫رقم‬ ‫شكل‬ ( 2 ) Multi core cable with flexible copper conductors PVC insulated and PVC sheathed 3 - ‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫كابالت‬ ‫مرنة‬ ( ‫شعر‬ ) ‫الـ‬ ‫بمادة‬ ‫ومعزولة‬ PVC ‫ومغلفة‬ ‫الـ‬ ‫بمادة‬ PVC ‫رقم‬ ‫شكل‬ ( 3 ) Single core cable ,with stranded circular copper conductors, PVC insulated and PVC sheathed 4 - ‫من‬ ‫مكونة‬ ‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫أحادية‬ ‫كابالت‬ ‫الـ‬ ‫بمادة‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ PVC ‫ومغلفة‬ ‫الـ‬ ‫بمادة‬ PVC ‫رقم‬ ‫شكل‬ ( 4 ) Multi core cables with stranded copper conductors PVC insulated and PVC sheathed 5 - ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫نحاس‬ ‫كابالت‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫من‬ ‫مكونة‬ ‫نحاس‬ ‫بالـ‬ PVC ‫الـ‬ ‫بمادة‬ ‫ومغلفة‬ PVC ‫رقم‬ ‫شكل‬ ( 5 )
  • 4. Multi core cables with stranded Aluminum conductors , PVC insulated and PVC sheathed . 6 - ‫ألومنيوم‬ ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫كابالت‬ ‫بمادة‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫من‬ ‫مكونة‬ ‫الـ‬ PVC ‫بال‬ ‫ومغلفة‬ PVC ‫رقم‬ ‫شكل‬ ( 6 ) Multi core cables with stranded copper conductors ,PVC insulated , steel tape armoured and PVC sheathed 7 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ PVC ‫ومسلحة‬ ‫بشريط‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 7 ) Multi core cables with stranded Aluminum conductors , PVC insulated , steel tape armoured and PVC sheathed 8 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫ألومونيو‬ ‫م‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ PVC ‫ومسلحة‬ ‫بشريط‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 8 ) Multi core cables with stranded copper conductors , PVC insulated , steel wires armoured and PVC sheathed 9 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ PVC ‫ومسلحة‬ ‫بأسالك‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 9 ) Multi core cables with stranded Aluminum conductors , PVC insulated , steel wires armoured and PVC sheathed 10 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫ألومونيو‬ ‫م‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ PVC ‫ومسلحة‬ ‫بأسالك‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 10 )
  • 5. ‫كابالت‬ ‫معزولة‬ ‫بمادة‬ ‫الـ‬ ( XLPE ) -: Single core cables with stranded circular copper conductors, XLPE insulated , and PVC sheathed 11 - ‫كابالت‬ ‫نحاس‬ ‫أحادية‬ ‫القطب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫دائرية‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ , XLPE ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 11 ) Multi core cables with stranded circular Copper conductors, XLPE insulated , and PVC sheathed 12 - ‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫األقطاب‬ ‫متعددة‬ ‫كابالت‬ ‫بما‬ ‫ومعزولة‬ ‫صلبة‬ ‫شعيرات‬ ‫من‬ ‫مكونة‬ ‫دائرية‬ ‫دة‬ ‫الـ‬ XLPE ‫الـ‬ ‫بمادة‬ ‫ومغلفة‬ PVC ‫رقم‬ ‫شكل‬ ( 12 ) Multi core cables with stranded circular Aluminum conductors , XLPE insulated , and PVC sheathed . 13 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫ألومونيوم‬ ‫دائرية‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 13 ) Multi core cables with stranded circular copper conductors , XLPE insulated, steel tape armoured , and PVC sheathed . 14 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫دائرية‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫معزولة‬ ‫بما‬ ‫دة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بشريط‬ ‫صلب‬ ‫ومغلفة‬ ‫بم‬ ‫ادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 14 ) Multi core cables with stranded circular Aluminum conductors ,XLPE insulated steel tape armoured and PVC sheathed 15 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫ألومونيوم‬ ‫دائرية‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بشريط‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 15 )
  • 6. Multi core cables , with stranded copper conductors , XLPE insulated steel tape armoured and PVC sheathed 16 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫مكونة‬ ‫من‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بأسالك‬ ‫صلب‬ ‫المغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 16 ) Multi core cables , with stranded Aluminum conductors , XLPE insulated steel tape armored and PVC sheathed 17 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫ألومونيوم‬ ‫عبارة‬ ‫عن‬ ‫شعيرات‬ ‫صلبة‬ ‫ومعزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بأسالك‬ ‫صلب‬ ‫ومغلف‬ ‫ة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 17 )
  • 24. 2.2Medium voltage cables ‫المتوسط‬‫الجهد‬‫كابالت‬ : From ( 6 --- 36) K.V * ‫التشغيل‬‫لجهد‬ ً‫طبقا‬‫الكابالت‬‫نواع‬‫ا‬ : - (6 / 10 – 12 ) K.V (8.7 / 15- 17.5) K.V (12 / 20 – 24 ) K.V ( 18 / 30 – 36 ) K.V
  • 25. ‫والتسليح‬ ‫العزل‬‫لنوع‬‫طبقا‬‫الكابالت‬‫نواع‬‫ا‬‫يلى‬‫وفيما‬ : - ‫المحلى‬‫لالنتاج‬‫وطبقا‬ Single & multi core copper conductor XLPE insulated and PVC sheathed 16 - ‫كابالت‬ ‫أحادية‬ ‫القطب‬ ‫ومتعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫ألمونيوم‬ ‫معزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 18 ) Single & multi core Aluminum conductor XLPE insulated and PVC sheathed 17 - ‫كابالت‬ ‫أحادية‬ ‫القطب‬ ‫ومتعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫معزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 19 ) Multi core copper & Aluminum conductor XLPE insulated , steel tape armoured and PVC sheathed 18 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫أوألومنيوم‬ ‫معزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بشريط‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 20 ) Multi core copper & Aluminum conductor XLPE insulated , steel wire armoured and PVC sheathed. 19 - ‫كابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫أوألومنيوم‬ ‫معزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بأسالك‬ ‫صلب‬ ‫ومغلفة‬ ‫بمادة‬ ‫الـ‬ PVC ‫شكل‬ ‫رقم‬ ( 21 )
  • 30. 2 .3 ‫العالى‬ ‫الجهد‬ ‫كابالت‬ : : 38 / 66 - 72.5 ) K.V ) High voltage cables Single core copper conductors , XLPE insulated , copper screened and HDPE sheathed 1 - ‫بمادة‬ ‫معزولة‬ ‫نحاس‬ ‫موصالت‬ ‫ذات‬ ‫القطب‬ ‫أحادى‬ ‫كابل‬ ‫الـ‬ XLPE ‫ب‬ ‫ومغلفة‬ ‫النحاس‬ ‫من‬ ‫شبك‬ ‫بسلك‬ ‫ومسلحة‬ ‫مادة‬ ‫ال‬ HDPE ‫رقم‬ ‫شكل‬ ( 22 ) Single core copper conductors , XLPE insulated , Lead screened and HDPE sheathed 2 - ‫كابل‬ ‫أحادى‬ ‫القطب‬ ‫ذات‬ ‫موصالت‬ ‫نحاس‬ ‫معزولة‬ ‫بمادة‬ ‫الـ‬ XLPE ‫ومسلحة‬ ‫بسلك‬ ‫شبك‬ ‫من‬ ‫الرصاص‬ ‫ومغلف‬ ‫ة‬ ‫بمادة‬ ‫ال‬ HDPE ‫شكل‬ ‫رقم‬ ( 23 )
  • 33.
  • 34. ‫الكهربائى‬ ‫الحمل‬ : Electrical Load ‫يجب‬ ‫اختيار‬ ‫مساحة‬ ‫مقطع‬ ‫الكابل‬ ‫بحيث‬ ‫ال‬ ‫تقل‬ ‫سعته‬ ‫لحمل‬ ‫التيار‬ ‫الكهربائى‬ ‫عن‬ ‫أقصى‬ ‫تيار‬ ‫تغذية‬ ‫وكذا‬ ‫يجب‬ ‫أال‬ ‫تتعدى‬ ‫درجة‬ ‫حرارة‬ ‫الكابل‬ ‫المناظرة‬ ‫لسعة‬ ‫حمل‬ ‫الت‬ ‫يار‬ ‫الكهربائى‬ ‫عن‬ ‫الدرجة‬ ‫المناسبة‬ ‫لنوعية‬ ‫عزل‬ ‫الكابل‬ ‫المستخدم‬ . ‫يجب‬ ‫أن‬ ‫تكون‬ ‫الكابالت‬ ‫الموصلة‬ ‫على‬ ‫التوازى‬ ‫من‬ ‫نفس‬ ‫النوع‬ ‫ولها‬ ‫نف‬ ‫س‬ ‫مساحة‬ ‫المقطع‬ ‫والطول‬ ‫بحيث‬ ‫تحمل‬ ‫فعليا‬ ‫تيارات‬ ‫متساوية‬ . ‫عند‬ ‫تحديد‬ ‫سعة‬ ‫حمل‬ ‫التيار‬ ‫للكابالت‬ ‫غير‬ ‫المعزولة‬ ‫يجب‬ ‫أن‬ ‫يؤخذ‬ ‫فى‬ ‫االعتبار‬ ‫الترتيبات‬ ‫الالزمة‬ ‫لتمددها‬ ‫وانكماشها‬ ‫والخواص‬ ‫الطبيعية‬ ‫للمعدن‬ ‫المصنوعة‬ ‫منه‬ ‫ويوصى‬ ‫أال‬ ‫تتعدى‬ ‫أقصى‬ ‫درجة‬ ‫حرارة‬ ‫الستخدام‬ ‫الكابالت‬ ‫غير‬ ‫المعزولة‬ 90ْ ‫م‬ . ‫اذا‬ ‫كان‬ ‫من‬ ‫الالزم‬ ‫مد‬ ‫كابل‬ ‫بطول‬ ‫محدد‬ ‫فى‬ ‫وسط‬ ‫ينتظر‬ ‫أن‬ ‫يتم‬ ‫عزله‬ ‫حرار‬ ‫يا‬ ‫فيجب‬ ‫تثبيت‬ ‫الكابل‬ ‫بحيث‬ ‫ال‬ ‫يتم‬ ‫تغطيته‬ ‫بالعزل‬ ‫الحرارى‬ ‫كلما‬ ‫أمكن‬ ‫ذلك‬ ‫وفى‬ ‫حا‬ ‫لة‬ ‫تعذر‬ ‫ذلك‬ ‫يجب‬ ‫تخفيض‬ ‫سعة‬ ‫حمل‬ ‫التيار‬ ‫للكابل‬ ‫بنسبة‬ ‫مالئمة‬ .
  • 35. ‫الجهد‬ ‫هبوط‬ : Voltage Drop ‫يجبْحسابْمساحةْمقطعْكلْكابلْغيرْمعزولْأوْمعزولْبماْالْيسمحْب‬ ْ‫تعدىْهبوطْالجهد‬ ‫منْنقطةْالتغذيةْالكهربائيةْحتىْأقصىْنقطةْفىْهذهْالتركيبات‬ ْ‫نسبة‬ 2.5 % ْ‫منْالجهد‬ ‫األسمىْوذلكْعندْالحملْالكابلْللموصالتْوذلكْطبقاْللكودْالمصرى‬ . ‫التعادل‬ ‫موصل‬ ‫مقطع‬ ‫مساحة‬ Neutral Cross Section ‫فى‬ ‫الدوائر‬ ‫متعددة‬ ‫األطوار‬ ‫التى‬ ‫يحتمل‬ ‫فيها‬ ‫حدوث‬ ‫عدم‬ ‫توازن‬ ‫األحمال‬ ‫ف‬ ‫ى‬ ‫األطوار‬ ‫الثالثة‬ ‫فى‬ ‫حالة‬ ‫االستخدام‬ ‫العادى‬ ‫بسبب‬ ‫االختالف‬ ‫الكبير‬ ‫فى‬ ‫تيار‬ ‫الحمل‬ ‫أو‬ ‫مع‬ ‫امل‬ ‫القدرة‬ ‫فى‬ ‫األطوار‬ ‫المختلفة‬ ‫أو‬ ‫تواجد‬ ‫تيارات‬ ‫توافقية‬ ( harmonics) ‫محسوسة‬ ‫فى‬ ‫األطوار‬ ‫المختلفة‬ ‫فيج‬ ‫ب‬ ‫اختيار‬ ‫موصل‬ ‫تعادل‬ ‫ذى‬ ‫مساحة‬ ‫مقطع‬ ‫كافية‬ ‫مساوية‬ ‫لمقطع‬ ‫الوجة‬ ‫لل‬ ‫كابل‬ ‫لحمل‬ ‫أقصى‬ ‫تيار‬ ‫يحتمل‬ ‫أن‬ ‫يمر‬ ‫فيه‬ . ‫فى‬ ‫الدوائر‬ ‫متعددة‬ ‫األطوار‬ ( 3 -phase) ‫التى‬ ‫ال‬ ‫يحتمل‬ ‫حدوث‬ ‫عدم‬ ‫اتزان‬ ‫ملحوظ‬ ‫بها‬ ‫أث‬ ‫ناء‬ ‫االستخدام‬ ‫العادى‬ ( ‫باستثناء‬ ‫دوائر‬ ‫االضاءة‬ ‫بالتفريغ‬ ) ‫فإنه‬ ‫يمكن‬ ‫ا‬ ‫ستخدام‬ ‫الكابالت‬ ‫متعددة‬ ‫األقطاب‬ ‫التى‬ ‫لها‬ ‫موصل‬ ‫تعادل‬ ‫ذو‬ ‫مساحة‬ ‫مقطع‬ ‫أصغر‬ ‫من‬ ‫المطلوب‬ ‫فى‬ ‫ح‬ ‫الة‬ ( ‫أ‬ ) ‫بعاليه‬ .
  • 36.
  • 37. ‫المغذيات‬ : Feeders ‫يجبْأنْتكونْقطاعاتهاْمناسبةْلنقلْاألحمالْالفعليةْالمطلو‬ ْ‫بة‬ + 25 % ْ‫احتياطى‬ ‫االسمى‬ ‫التيار‬ : Nominal current ‫يرجعْالىْجداولْتحميلْاالسالكْوالكابالتْطبقاْللتصنيعْم‬ ْ‫عْمراعاةْتعديلْأحمال‬ ‫الكابالتْطبقاْلدرجةْحرارةْالجوْوعددْالكابالتْفىْالمسارْالواح‬ ْ‫د‬ . ‫الجهد‬ ‫هبوط‬ : Voltage Drop ‫يتم‬ ‫تصميم‬ ‫المغذيات‬ ‫الرئيسية‬ ‫والثانوية‬ ‫والفرعية‬ ‫بحي‬ ‫ث‬ ‫ال‬ ‫تتجاوز‬ ‫الهبوط‬ ‫الكلى‬ ‫فى‬ ‫الجهد‬ ‫بين‬ ‫نقطة‬ ‫التغذية‬ ‫الرئيسية‬ ‫للجهد‬ ‫المنخفض‬ ‫بالمب‬ ‫نى‬ ‫وأى‬ ‫نقطة‬ ‫تغذية‬ ‫فى‬ ‫التركيبات‬ ‫عن‬ 2.5 % ‫من‬ ‫الجهد‬ ‫األسمى‬ ‫للتغذية‬ ‫وذلك‬ ‫عند‬ ‫مرور‬ ‫أقصى‬ ‫قيمة‬ ‫منتظرة‬ ‫لتيار‬ ‫التشغيل‬ ‫الفعلى‬ ‫فى‬ ‫هذه‬ ‫الموصالت‬ . ‫ويستثنى‬ ‫من‬ ‫ذلك‬ ‫المغذيات‬ ‫الخاصة‬ ‫بتشغيل‬ ‫المحركات‬ ‫حيث‬ ‫يسمح‬ ‫بهبوط‬ ‫فى‬ ‫الجهد‬ ‫حتى‬ 5 % ‫من‬ ‫الجهد‬ ‫األسمى‬ ‫للتغذية‬ ‫عند‬ ‫الحمل‬ ‫الكامل‬ .
  • 38. Neutral conductor cross section in 3 phase-systems ‫األط‬ ‫ثالثية‬ ‫المغذيات‬ ‫فى‬ ‫التعادل‬ ‫موصل‬ ‫مقطع‬ ‫وار‬ . ‫يرتبطْمقطعْالموصلْالمتعادلْبمقطعْموصلْالطورْفىْالم‬ ْ‫غذياتْثالثية‬ ‫األطوارْعلىْالوجةْالتالى‬ : - ْ‫اذاْكانْمقطعْموصلْالطورْفىْحدود‬ 16 ‫مم‬ 2 ْ‫نختارْموصلْالتعادلْبنفس‬ ْ‫مقطعْموصلْْالطور‬ (phase) ْ‫اذاْتراوحْمقطعْموصلْالطورْبين‬ ( 35 ‫مم‬ 2 ْ، 25 ‫مم‬ 2 ) ْ‫يحتارْموصلْالتعادل‬ ‫بمقطعْالْيقلْعنْالمقطعْالتالىْفىْالصغرْلمقطعْموصل‬ ْ‫الطور‬ . ْ‫اذاْكانْموصلْالطورْالْيقلْعن‬ 50 ‫مم‬ 2 ‫نختارْموصلْالتعادلْبمقطعْالْي‬ ْ‫قل‬ ْ‫عنْنصفْمقطعْموصلْالطور‬ ‫مثال‬ ( : 3 × 50 + 25 ‫مم‬ 2 ) ْ، ( 3 × 70 + 35 ‫مم‬ 2 )
  • 39. 4.5 Cross section of conductors in branch lighting circuits ‫النهائية‬ ‫الفرعية‬ ‫الدوائر‬ ‫موصالت‬ ‫مقطع‬ ( ‫االضاءه‬ ‫دوائر‬ ‫فى‬ ) ‫عند‬ ‫تصميم‬ ‫مقطع‬ ‫موصالت‬ ‫الدوائر‬ ‫الفرعية‬ ‫النهائية‬ ‫التى‬ ‫تغذى‬ ‫عددا‬ ‫م‬ ‫ن‬ ‫مخارج‬ ‫االضاءه‬ ‫أو‬ ‫المآخذ‬ ‫الكهربائية‬ ‫المخصصة‬ ‫لألجهزة‬ ‫الكهربائية‬ ‫االضاءه‬ ‫يراعى‬ ‫اآلتى‬ : ‫يحسب‬ ‫الحمل‬ ‫الفعلى‬ ‫لكل‬ ‫مخرج‬ ‫اضاءه‬ ‫أو‬ ‫مأخذ‬ ( ‫بريزه‬ ) ‫على‬ ‫أساس‬ 100 ‫وات‬ ‫لكل‬ ‫مخرج‬ ‫على‬ ‫األقل‬ ‫مهما‬ ‫كان‬ ‫الحمل‬ ‫الفعلى‬ ‫أقل‬ ‫من‬ ‫ذلك‬ ‫أما‬ ‫اذا‬ ‫زاد‬ ‫الحمل‬ ‫الفعلى‬ ‫عن‬ ‫ذلك‬ ‫فيحسب‬ ‫على‬ ‫أساس‬ ‫الحمل‬ ‫الفعلى‬ . ‫فى‬ ‫حالة‬ ‫األحمال‬ ‫الحثية‬ ( ‫ذات‬ ‫الملفات‬ ) ‫أو‬ ‫المصابيح‬ ‫التى‬ ‫تعمل‬ ‫بالتف‬ ‫ريغ‬ ‫الكهربائى‬ ‫وتدخل‬ ‫فى‬ ‫دائرتها‬ ‫ملفات‬ ‫حثيه‬ ‫يحسب‬ ‫التيار‬ ‫على‬ ‫أساس‬ 125 % ‫من‬ ‫التيار‬ ‫الفعلى‬ ‫المار‬ ‫بالدائرة‬ . ْ ‫ا‬‫ال‬‫فمث‬ ‫فى‬ ‫حالى‬ ‫مصباح‬ ‫فللورى‬ ‫قدره‬ 40 ‫وات‬ ( ‫يدخل‬ ‫فى‬ ‫دائرتة‬ ‫ملف‬ ‫حثى‬ ) ‫لتشغيله‬ ‫م‬ ‫ن‬ ‫مصدر‬ ‫التيار‬ ‫المتردد‬ ‫جهده‬ ( 220 ‫فولت‬ ) ‫يمر‬ ‫فى‬ ‫دائرتة‬ ‫تيار‬ ‫شدته‬ 0.42 ‫أمبير‬ ( ‫باعتبار‬ ‫معامل‬ ‫القدرة‬ 0.43 ) ‫يحسب‬ ‫مقطع‬ ‫موصل‬ ‫الدائرة‬ ‫على‬ ‫أساس‬ ‫تيار‬ ‫شدته‬ 0.52 ‫أمبير‬ ‫أى‬ 1.25 ‫التيار‬ ‫الفعلى‬ ‫وذلك‬ ‫اذا‬ ‫لم‬ ‫يزود‬ ‫المصباح‬ ‫بمكثف‬ ‫تحسين‬ ‫القدرة‬ . ‫أما‬ ‫اذا‬ ‫زود‬ ‫بمكثف‬ ‫تحسين‬ ‫معامل‬ ‫القدرة‬ ‫يمر‬ ‫فى‬ ‫دائرة‬ ‫المصباح‬ ‫تيار‬ ‫فى‬ ‫حدود‬ 0.23 ‫أمبير‬ ( ‫باعتبار‬ ‫معامل‬ ‫القدرة‬ 0.8 ) ‫ويحسب‬ ‫مقطع‬ ‫موصل‬ ‫الدائرة‬ ‫على‬ ‫أساس‬ ‫تيار‬ ‫شدته‬ 0.29 ‫أمبير‬ ‫أى‬ 1.25 ‫من‬ ‫التيار‬ ‫الفعلى‬ . ‫ال‬ ‫يقل‬ ‫مقطع‬ ‫موصالت‬ ‫الدوائر‬ ‫الفرعية‬ ‫النهائية‬ ‫والمخارج‬ ‫لالنارة‬ ‫عن‬ 2 ‫مم‬ 2 ‫والبرايز‬ ‫عن‬ 3 ‫مم‬ 2 ‫مهما‬ ‫كان‬ ‫حملها‬ ‫الفعلى‬ ْ ‫ا‬‫ا‬‫صغير‬ . ‫تكون‬ ‫موصالت‬ ‫كل‬ ‫دائرة‬ ‫فرعية‬ ‫نهائية‬ ‫منفصله‬ ْ ‫ا‬‫ا‬‫تمام‬ ‫عن‬ ‫موصالت‬ ‫أيه‬ ‫د‬ ‫ائرة‬ ‫أخرى‬ ‫وال‬ ‫تشترك‬ ‫معها‬ ‫فى‬ ‫أى‬ ‫جزء‬ ‫منها‬ ‫حتى‬ ‫فى‬ ‫الموصالت‬ ‫المتصلة‬ ‫بقطب‬ ‫التعادل‬ .
  • 40.  ‫يجوزْاشتراكْموصالتْدائرتينْفرعيتينْنهائيتينْفىْماسورة‬ ْ‫واحدةْبشرطْأنْتكونْكل‬ ْ‫منهاْمغذاهْمنْنفسْالطورْمنْمصدرْالتغذية‬ . 4.6 Branch circuits for( sockets & lighting outlets) ‫والمآخذ‬ ‫االضاءه‬ ‫وحدات‬ ‫لمخارج‬ ‫النهائية‬ ‫الفرعية‬ ‫الدوائر‬ :  ‫يراعى‬ ‫تحميل‬ ‫مخارج‬ ‫المآخذ‬ ‫الكهربائية‬ ‫على‬ ‫دوائر‬ ‫فرعية‬ ‫نهائية‬ ‫م‬ ‫ستقلة‬ ‫عن‬ ‫الدوائر‬ ‫الفرعية‬ ‫النهائية‬ ‫الخاصة‬ ‫بمخارج‬ ‫االناره‬ .  ‫يراعى‬ ‫أال‬ ‫يزيد‬ ‫عدد‬ ‫مخارج‬ ‫االنارة‬ ‫أو‬ ‫المأخذ‬ ‫الكهربائية‬ ‫التى‬ ‫تستعم‬ ‫ل‬ ‫ألجهزة‬ ‫االنارة‬ ‫والتى‬ ‫تحمل‬ ‫على‬ ‫دائرة‬ ‫فرعية‬ ‫نهائية‬ ‫واحدة‬ ‫عن‬ ‫عشرة‬ ‫مخارج‬ .  ‫ال‬ ‫يزيد‬ ‫مقطع‬ ‫الموصالت‬ ‫التى‬ ‫تغذى‬ ‫مخارج‬ ‫االنارة‬ ‫والمأخذ‬ ‫عن‬ ‫مقطع‬ ‫الدوائر‬ ‫الفرعية‬ ‫النهائية‬ ‫التى‬ ‫تغذيها‬ .
  • 41.
  • 42. 5 . Maximum demand and diversity factor ‫التباين‬ ‫ومعامل‬ ‫المطلوب‬ ‫األقصى‬ ‫الحمل‬ : ‫الك‬ ‫للتركيبات‬ ‫المطلوب‬ ‫األقصى‬ ‫الحمل‬ ‫حساب‬ ‫طريقة‬ ‫بتغذية‬ ‫تقوم‬ ‫والتى‬ ‫هربائية‬ ‫معامل‬ ‫تطبيق‬ ‫الى‬ ‫باالضافة‬ ‫االستخدام‬ ‫شائعة‬ ‫األجهزة‬ ‫المسموح‬ ‫التباين‬ : - 1 - ‫يحسب‬ ‫التيار‬ ‫األقصى‬ ‫المطلوب‬ ‫للدوائر‬ ‫النهائية‬ ‫الفرعية‬ ‫ب‬ ‫جميع‬ ‫تيارات‬ ‫كافة‬ ‫نقط‬ ‫االستخدام‬ ( ‫المآخذ‬ ‫والبرايز‬ ) ‫واألجهزة‬ ‫الثابتة‬ ‫على‬ ‫الدوائر‬ ‫مع‬ ‫ت‬ ‫طبيق‬ ‫معامل‬ ‫التباين‬ ‫طبقا‬ ‫لما‬ ‫هو‬ ‫موضح‬ ‫بالجدول‬ ( 1 ) . 2 - ‫يتم‬ ‫تحديد‬ ‫التيار‬ ‫الفعلى‬ ‫المطلوب‬ ‫لدائرة‬ ‫تغذى‬ ‫مجموعة‬ ‫دوائ‬ ‫ر‬ ‫عمومية‬ ( ‫نهائية‬ ) ‫باستعمال‬ ‫معامالت‬ ‫التباين‬ ‫الموضحة‬ ‫فى‬ ‫الجدول‬ ( 2 ) ‫التى‬ ‫تطبق‬ ‫على‬ ‫التيارات‬ ‫الفعلية‬ ‫لجميع‬ ‫األجهزة‬ ‫المغذاه‬ ‫بهذه‬ ‫الدائرة‬ ‫وليس‬ ‫بجمع‬ ‫التي‬ ‫ار‬ ‫الفعلى‬ ‫للدوائر‬ ‫العمومية‬ ‫النهائية‬ ‫المغذاه‬ . 3 - ‫بعد‬ ‫تحديد‬ ‫تيار‬ ‫التصميم‬ ‫لجميع‬ ‫الدوائر‬ ‫يتم‬ ‫تحديد‬ ( ‫اختب‬ ‫ار‬ ) ‫مقطع‬ ‫موصالت‬ ‫الدوائر‬ ‫ويجب‬ ‫مراجعة‬ ‫الحد‬ ‫المسموح‬ ‫به‬ ‫فى‬ ‫هبوط‬ ‫الجهد‬ .
  • 43. ‫جدول‬ ( 1 ) ‫التيار‬ ‫تقدير‬ ‫اإلستخدام‬ ‫لنقط‬ ‫الكهربى‬ ‫الكهربائية‬ ‫واألجهزة‬ ‫المصــرى‬ ‫للكـود‬ ً‫ا‬‫طبق‬
  • 45. ‫جدول‬ ‫تابع‬ ( 2 ) ‫حاالت‬ ‫معامالت‬ ‫بإستخدام‬ ‫السماح‬ ‫التباين‬ ‫الموصالت‬ ‫مقاطع‬ ‫لحساب‬ ‫لألغراض‬ ‫الكهربائية‬ ‫المختلفة‬ ‫والمنشآت‬ ‫المصرى‬ ‫للكود‬ ‫طبقا‬
  • 46.
  • 47. 6 . Circuit design ‫الدوائر‬ ‫تصميم‬ ‫فيماْيلىْكيفيةْتصميمْالدوائرْالمختلفةْوحسابْمقاطعْالموصالتْوالكاب‬ ْ‫التْحتىْيمكنْتحديدْأجهزة‬ ( ‫نبائط‬ ) ْ‫الوقايةْضدْزيادةْالحملْوقصرْالدائرة‬ . * - ‫التالية‬ ‫األساسية‬ ‫للخطوات‬ ‫طبقا‬ ‫الحسابات‬ ‫تتم‬ : - ‫األولى‬ ‫الخطوة‬ : ْ‫تحديدْقيمةْالتيارْالتصميمى‬ ( I ) ( design current ) ‫الثانية‬ ‫الخطوة‬ : ْْْْْْْْْْْْْْْْْْْ‫اختيارْتيارْالوقاية‬ ( In ) ( protection current ) ‫الثالثة‬ ‫الخطوة‬ : ْْ‫اختيارْمعامالتْالتصحيحْالمناسبةْلكلْحالة‬ Relevant correction factors ‫الرابعة‬ ‫الخطوة‬ : ْ‫حسابْمعاملْالتصحيحْالكلى‬ (C.F ) total correction factor calculation of Cable current carrying capacity (IZ ) ‫الخامسة‬ ‫الخطوة‬ : ‫حسابْالسعةْالتياريةْل‬ ‫لكابل‬ Iz ‫التالية‬ ‫البنود‬ ‫مراجعة‬ ‫تتم‬ : .1 ْ‫اختيارْمساحةْمقطعْالكابلْالمناسبْللتيار‬ ( Iz ) .2 ْ‫مراجعةْالهبوطْفيْالجهد‬ .3 ‫حسابْتياراتْالقصر‬ F C In . 
  • 48. ‫االولى‬ ‫الخطوه‬ : ‫التصميمي‬ ‫التيار‬ ‫قيمة‬ ‫تحديد‬ Nominal current ‫التيار‬ ( ‫الطور‬ ‫احادي‬ ) I ‫فاءة‬‫الك‬ ‫فى‬ ‫حالة‬ ‫القدرة‬ ‫التى‬ ‫بها‬ ‫اء‬‫ز‬‫ج‬‫ا‬ ‫متحركة‬ :  ‫قدرة‬ ‫الخرج‬ ‫بالوات‬ P: (Output power) ( 220 ‫فولت‬ ) ‫الجهد‬ ‫بالفولت‬ v: (Nominal voltage) ‫معامل‬ ‫القدرة‬ P.F: (Power factor)     F P V P . I
  • 49. * ‫الثانية‬ ‫الخطوة‬ : ‫الوقاية‬ ‫تيار‬ ‫قيمة‬ ‫تحديد‬ In protection current ْ‫بعدْتحديدْنسبةْالتيارْالتصميمى‬ I ْ‫يلزمْاختيارْقيمةْتيارْالوقاية‬ In ْ‫بحيثْيكون‬ In>I ْ‫ويتمْاختيارْالتيار‬ In ‫منْالجداولْالخاصةْبتحميلْالكابالتْالتىْيتمْاعدادهاْبواس‬ ْ‫طةْالشركاتْالمنتجة‬ ْ‫لها‬ 6.3 choice of Correction factor * ‫الثالثة‬ ‫الخطوة‬ : ‫التصحيح‬ ‫معامالت‬ ‫اختيار‬ C.F ‫حالة‬ ‫لكل‬ ‫المناسبة‬ : - ْ‫عندماْيمرْتيارْالحملْالكامل‬ (full load) ‫ْوهذ‬‫ا‬‫ا‬‫فىْموصلْمعزولْأوْكابلْفإنهْيصبحْدافئ‬ ْ‫اْالْيسبب‬ ‫عادةْأىْمشاكلْاالْفىْحالةْتعرضهْالرتفاعْآخرْفىْدرجةْالحرارةْكنتيجةْلمؤث‬ ْ‫راتْأخرىْمماْيؤدى‬ ْ‫إلىْارتفاعْزائدْفىْدرجةْالحرارةْمماْقدْيؤدىْالىْانهيارْالعزل‬ ‫هى‬ ‫األخرى‬ ‫والمؤثرات‬ :  ْ‫ارتفاعْدرجةْحرارةْالوسطْالمحبط‬  ‫تجميعْالكابالتْمعاْفىْمكانْمغلق‬  ‫التعرضْلتيارْزائدْلمدةْطويله‬  ْ‫المالمسةْمعْمادةْعازلةْللحرارة‬ .
  • 50. ‫ولكل‬ ‫من‬ ‫هذه‬ ‫المؤثرات‬ ‫معامل‬ ‫تصحيح‬ ‫يؤدى‬ ‫الى‬ ‫خفض‬ ‫قيمة‬ ‫أقصى‬ ‫تيار‬ ‫ويتم‬ ‫حساب‬ ‫هذه‬ ‫القيمة‬ ‫على‬ ‫النحو‬ ‫التالى‬ : - ‫معامل‬ ‫تأثير‬ ‫درجة‬ ‫حرارة‬ ‫الوسط‬ ‫المحيط‬ (Ca) ‫ويرجع‬ ‫فى‬ ‫تحديده‬ ‫الى‬ ‫جدول‬ ‫رقم‬ ( 3 ) ‫معامل‬ ‫تجميع‬ ‫الكابالت‬ (grouping ) ‫فى‬ ‫مسار‬ ‫واحد‬ “Cg” ‫حيث‬ ‫يؤدى‬ ‫تجميع‬ ‫الكابال‬ ‫ت‬ ‫معا‬ ‫الى‬ ‫أن‬ ‫تبث‬ ‫حرارتها‬ ‫وتؤثر‬ ‫على‬ ‫بعضها‬ ‫البعض‬ ‫ويرجع‬ ‫فى‬ ‫تحدي‬ ‫د‬ ‫هذا‬ ‫المعامل‬ ‫الى‬ ‫جدول‬ ‫رقم‬ ( 4 ) ‫مع‬ ‫مالحظة‬ ‫األتى‬ : ‫الجدول‬ ‫رقم‬ ( 4 ) ‫محسوب‬ ‫لعدد‬ ‫من‬ ‫الكابالت‬ ‫موجوده‬ ‫بجوار‬ ‫بعضها‬ ‫وذات‬ ‫مق‬ ‫اطع‬ ‫متساوية‬ . ‫من‬ ‫الحاالت‬ ‫المتكررة‬ ‫والتى‬ ‫تتطلب‬ ‫تطبيق‬ ‫معامل‬ ‫تجميع‬ ‫الكابال‬ ‫ت‬ ‫هى‬ ‫التغذية‬ ‫الكهربائية‬ ‫لدوائر‬ ‫إنارة‬ ‫المصانع‬ ‫الكبيرة‬ ‫حيث‬ ‫يتم‬ ‫تمديد‬ ‫الكابالت‬ ‫على‬ ‫حوام‬ ‫ل‬ ‫أو‬ ‫داخل‬ ‫نظام‬ ‫للصندوق‬ ‫وتكون‬ ‫الكابالت‬ ‫فى‬ ‫هذه‬ ‫الحالة‬ ‫ذات‬ ‫مقاطع‬ ‫متساوية‬ ‫ويت‬ ‫م‬ ‫تحميلها‬ ‫بالتيار‬ ‫الفعلى‬ ‫الكلى‬ ‫فى‬ ‫نفس‬ ‫الوقت‬ . ‫اذا‬ ‫تمت‬ ‫الوقاية‬ ‫باستخدام‬ ‫مصاهر‬ ‫ذات‬ ‫خواص‬ ‫خاصة‬ ‫وبطيئة‬ ‫زمنيا‬ ‫ط‬ ‫بقا‬ ‫للمواصفات‬ (IEC-269-3) ‫فيتم‬ ‫اختيار‬ ‫التيار‬ ‫المقنن‬ In ‫بحيث‬ ‫يكون‬ ‫أقل‬ ‫من‬ ‫أو‬ ‫مساوى‬ ‫للقيم‬ ‫ة‬ ( 0.725 Iz) ‫أى‬ ‫كالتالى‬ : In< 0.725Iz
  • 51. ‫هو‬ ‫المقنن‬ ‫المصهر‬ ‫تيار‬ ‫أن‬ ‫حيث‬ In ‫ويكون‬ ‫معامل‬ ‫التصحيح‬ Cf ‫الذى‬ ‫ينبغى‬ ‫تطبيقه‬ ‫فى‬ ‫هذه‬ ‫الحالة‬ ‫مساويا‬ ‫للقيمة‬ 0.725 ‫معامل‬ ‫المالمسة‬ ‫مع‬ ‫عزل‬ ‫حرارى‬ ( thermal insulation ) ‫مع‬ ‫زيادة‬ ‫االتجاة‬ ‫الى‬ ‫ترشيد‬ ‫استهالك‬ ‫الطاقة‬ ‫وذلك‬ ‫باستخدام‬ ‫مواد‬ ‫عازلة‬ ‫فى‬ ‫البناء‬ ‫فإنه‬ ‫يجب‬ ‫أخذ‬ ‫عنصر‬ ‫احتجاز‬ ‫الح‬ ‫رارة‬ ‫فى‬ ‫االعتبار‬ ‫وقيم‬ ‫سعة‬ ‫حمل‬ ‫التيار‬ ‫الواردة‬ ‫الجداول‬ ‫المرفقة‬ ‫معطاه‬ ‫على‬ ‫أساس‬ ‫أن‬ ‫الكابل‬ ‫مالم‬ ‫س‬ ‫لمادة‬ ‫عازلة‬ ‫للحرارة‬ ‫من‬ ‫جهة‬ ‫واحدة‬ ‫أما‬ ‫اذا‬ ‫كان‬ ‫الكابل‬ ‫محاطا‬ ‫بهذه‬ ‫المادة‬ ‫العازلة‬ ‫للحرارة‬ ‫فإن‬ ‫المعامل‬ Ci ‫المستخدم‬ Ci=0.5 ‫الكلى‬ ‫التصحيح‬ ‫معامل‬ ‫حساب‬ : calculation of total correction factors ‫ت‬ ‫معا‬ ‫تتطلب‬ ‫التى‬ ‫الحاالت‬ ‫من‬ ‫أكثر‬ ‫أو‬ ‫لواحد‬ ‫مساره‬ ‫خالل‬ ‫يتعرض‬ ‫قد‬ ‫الكابل‬ ‫أن‬ ‫يالحظ‬ ‫طبيق‬ ‫اال‬ ‫فى‬ ‫األمر‬ ‫هذا‬ ‫أخذ‬ ‫يجب‬ ‫لذا‬ ‫الوقت‬ ‫نفس‬ ‫فى‬ ‫جميعها‬ ‫أو‬ ‫بعضها‬ ‫سواء‬ ‫التصحيح‬ ‫معامالت‬ ‫عتبار‬ ‫الكلى‬ ‫التصحيح‬ ‫معامل‬ ‫تحديد‬ ‫عند‬ C.F ‫ما‬ ‫كابل‬ ‫على‬ ‫تطبيقه‬ ‫ينبغى‬ ‫الذى‬
  • 54. 6.5 calculation of current carrying capacity * ‫الخامسة‬‫الخطوة‬ : ‫للكابل‬‫ية‬‫ر‬‫التيا‬‫السعة‬‫حساب‬ Iz ‫للمواص‬ ‫طبقا‬ ‫مصهر‬ ‫فات‬ IEC269-3 ‫عالى‬ ‫أداء‬ ‫ذو‬ Ci= 0.5 Cg= 0.7 Ca= 0.97 30 A ‫كهربائى‬ ‫حمل‬ ‫مثال‬ ( 1 ) ‫التالية‬‫المعادلة‬ ‫تطبيق‬‫يتم‬ ‫المبين‬‫الشكل‬‫فى‬‫المبين‬‫للكابل‬‫التيارية‬‫السعة‬‫قيمة‬‫لحساب‬ : F C In Iz .  ‫للمصهر‬‫التصحيح‬‫معامل‬‫فإن‬‫عالى‬‫داء‬‫ا‬‫ذو‬‫المستخدم‬‫المصهر‬‫ن‬‫ا‬ ‫حيث‬ Cf = 1 ‫التصحيح‬‫معامل‬ ‫ويكون‬ Ca" " ‫يتعرض‬‫الذى‬‫الكابل‬‫من‬‫للجزء‬ ‫للتجميع‬‫التصحيح‬‫ومعامل‬‫المحيط‬‫الوسط‬ ‫ارة‬‫ر‬‫ح‬‫لدرجة‬ Cg ‫ن‬‫ا‬‫ى‬‫ا‬‫ضربهما‬‫لحاصل‬ ً‫مساويا‬ ‫خرى‬‫ا‬‫كابالت‬‫مع‬ : - Cg x Ca = 0.7 x 0.97
  • 55. ْ‫ويكونْمعاملْالتصحيح‬ Ci ‫للجزءْمنْالكابلْالمحاطْبعازلْحرارىْكاملْم‬ ْ‫ساويا‬ ْ‫للقيمة‬ 0.5 ْ‫ويتضحْمنْهذاْأنْالمعامل‬ Ci ‫هوْأقلْمعاملْبالمقارنةْبالحالةْال‬ ْ‫تىْيتم‬ ْ‫فيهاْتطبيق‬ Cg.Ca ْ‫لذاْفإنْمعاملْالتصحيحْالكلىْللكابلْهو‬ : = Cf.Ci = 1 x 0.5 = 0.5 Cf ْ‫وبذلكْفإنْالسعةْالتيارية‬ Iz ْ‫هى‬ : A Iz 60 5 . 0 30   ‫مثال‬ 2 ) ‫كالحالة‬ ‫السابقة‬ ‫ولكن‬ ‫المصهر‬ ‫المستخدم‬ ‫ذو‬ ‫أداء‬ ‫خاص‬ ( ‫بطىء‬ ) ‫ومن‬ ‫طراز‬ ‫ينتج‬ ‫طبقا‬ ‫للمواصفات‬ ‫الكهروميكانيكية‬ ‫العالمية‬ IEC269-3 ‫تتكون‬ ‫فيه‬ ‫معامل‬ ‫التصحيح‬ ‫للمصهر‬ Cf ‫هى‬ 0.725 ‫وتكون‬ ‫قيمة‬ ‫السعة‬ ‫التيارية‬ Iz ‫هى‬ : A Ci C Iz f 75 . 82 5 . 0 725 . 0 30 30     
  • 56. Ci= 0.5 Cg= 0.5 Ca= 0.97 30 A ‫كهربائى‬ ‫حمل‬ ‫مثال‬ 3 ) ‫فى‬ ‫هذا‬ ‫المثال‬ ‫فإن‬ ‫معامل‬ ‫التصحيح‬ ‫لكل‬ ‫من‬ ‫درجة‬ ‫ارة‬‫ر‬‫ح‬ ‫الوسط‬ ‫المحيط‬ Ca ‫وتجميع‬ ‫الكابالت‬ Cg ‫ليصبح‬ ‫حاصل‬ ‫ضربها‬ ‫هو‬ 0.485 ‫وهى‬ ‫قل‬‫ا‬ ‫من‬ ‫قيمة‬ ‫معامل‬ ‫التصحيح‬ Ci ‫نتيجة‬ ‫لمالصقة‬ ‫الكابل‬ ‫لعازل‬ ‫ى‬‫ار‬‫ر‬‫ح‬ ‫وقيمته‬ 0.5 ‫وحيث‬ ‫ن‬‫ا‬ ‫المصهر‬ ‫المستخدم‬ ‫ذا‬ ‫داء‬‫ا‬ ‫خاص‬ ‫طبقا‬ ‫للمواصفات‬ ‫الكهروتقنية‬ IEC269.3 ‫فإن‬ ‫معامل‬ ‫تصحيح‬ ‫المصهر‬ Cf ‫يكون‬ ‫مساويا‬ ‫للقيمة‬ 0.725 ‫وبذلك‬ ‫يصبح‬ ‫معامل‬ ‫التصحيح‬ ‫الكلى‬ Cf ‫للكابل‬ ‫مساويا‬ ‫تى‬‫ال‬ : . x Ca x Cg Cf = f C ‫هى‬‫للكابل‬‫التيارية‬‫السعة‬‫وتكون‬ : - A Iz 3 . 85 485 . 0 725 . 0 30   
  • 57. 6 . 6 Revision of some items ‫الخطوة‬ ‫السادسة‬ : ‫مراجعة‬ ‫بعض‬ ‫البنود‬ ‫التالية‬ : 1 - ‫يتم‬ ‫اختيار‬ ‫مساحة‬ ‫مقطع‬ ‫الكابل‬ ‫المناسب‬ ‫للسعة‬ ‫التيارية‬ ‫للكابل‬ ‫بع‬ ‫د‬ ‫تطبيق‬ ‫معامالت‬ ‫التصحيح‬ ‫وطبقا‬ ‫لجداول‬ ‫التحميل‬ ‫المعدة‬ ‫بواسطة‬ ‫المصنع‬ . 2 - ‫مراجعة‬ ‫هبوط‬ ‫الجهد‬ : voltage drop ‫ترتبط‬ ‫قيمته‬ ‫الهبوط‬ ‫فى‬ ‫الجهد‬ ‫للموصل‬ ‫بقيمة‬ ‫مقاومته‬ ‫والتيار‬ ‫المار‬ ‫فيه‬ ‫ولذل‬ ‫ك‬ ‫فإن‬ ‫جهد‬ ‫الدائرة‬ ‫عند‬ ‫الحمل‬ ‫قد‬ ‫يقل‬ ‫عن‬ ‫المسموح‬ ‫به‬ ‫اذا‬ ‫كانت‬ ‫الموصالت‬ ‫التى‬ ‫تغذى‬ ‫الحمل‬ ‫ذات‬ ‫مساحة‬ ‫مقطع‬ ‫صغيرة‬ . ‫وتتطلب‬ ‫هذه‬ ‫االشتراطات‬ ‫أال‬ ‫ينخفض‬ ‫الجهد‬ ‫عند‬ ‫الحمل‬ ‫الكامل‬ ‫بأكثر‬ ‫من‬ 2.5 % ‫من‬ ‫قيمته‬ ‫عند‬ ‫نقطة‬ ‫التغذية‬ ‫الرئيسية‬ ‫وعلى‬ ‫ذلك‬ : ‫يكون‬ ‫أقصى‬ ‫هبوط‬ ‫فى‬ ‫الجهد‬ ‫مسموح‬ ‫به‬ ‫ال‬ ‫يتعدى‬ 5.5 ‫فولت‬ ‫فى‬ ‫حالة‬ ‫التغذية‬ ‫بدائرة‬ ‫ذات‬ ‫طور‬ ‫واحد‬ (single phase) ‫على‬ ‫جهد‬ 220 ‫فولت‬ . ‫وفى‬ ‫حالة‬ ‫التغذية‬ ‫بدائرة‬ ‫ذات‬ ‫ثالثة‬ ‫أطوار‬ ‫على‬ ‫جهد‬ ‫خطى‬ 380 ‫فولت‬ ‫فإن‬ ‫أقصى‬ ‫هبوط‬ ‫مسموح‬ ‫به‬ ‫فى‬ ‫جه‬ ‫د‬ ‫الخط‬ ‫ال‬ ‫يتعدى‬ 9.5 ‫فولت‬ . ‫حساب‬ ‫هبوط‬ ‫الجهد‬ : calculation of voltage drop ‫يمكن‬ ‫حساب‬ ‫قيمة‬ ‫هبوط‬ ‫الجهد‬ ‫من‬ ‫العالقة‬ ‫التالية‬ : 1000 L I mV Vc B   
  • 58. ‫حيث‬ : - ‫بالفولت‬‫الجهد‬‫هبوط‬ VC: ‫مبير‬‫بال‬‫للكابل‬‫التصميمى‬‫التيار‬ IB: ‫بالمتر‬‫الموصل‬‫و‬‫ا‬‫الكابل‬‫طول‬ L: ‫فولت‬‫بالمللى‬‫الموصل‬‫و‬‫ا‬‫الكابل‬‫فى‬‫النوعى‬ ‫الجهد‬‫هبوط‬ / ‫مبير‬‫ا‬ / ‫طولى‬‫متر‬ mV: ‫لومونيوم‬‫ال‬‫و‬‫ا‬‫النحاس‬‫من‬ ‫القطاعات‬‫لجميع‬‫بذلك‬‫الخاص‬‫الجدول‬‫ومرفق‬ ‫المسموح‬ ‫القيمة‬ ‫فية‬ ‫الجهد‬ ‫هبوط‬ ‫يتعدى‬ ‫ال‬ ‫بحيث‬ ‫الموصل‬ ‫أو‬ ‫للكابل‬ ‫طول‬ ‫أقصى‬ ‫تقدير‬ ‫ويمكن‬ ‫من‬ ‫بها‬ ‫التاليه‬ ‫المعادلة‬ ‫واقع‬ : - ‫للكابل‬‫طول‬ ‫قصى‬‫ا‬ = ‫به‬‫مسموح‬‫جهد‬‫هبوط‬‫قصى‬‫ا‬ x 1000 IB X mV ‫به‬‫مسموح‬‫جهد‬‫هبوط‬‫قصى‬‫ا‬‫ستعمال‬‫ا‬‫مع‬ ( 5.5 ‫فولت‬ ) , ‫و‬‫ا‬ ( 9.5 ‫فولت‬ ) ‫التغذية‬‫دائره‬‫لنوع‬ ‫طبقا‬ . ‫جدولى‬ ( 5 ، 6 )
  • 59. Tables of Voltage Drop / Ampere / meter for each cross – section : - * For Copper Cables: - * For Aluminum Cross section mV/A/m 4 mm² 6mm² 10mm² 16mm² 25mm² 35mm² 50mm² 70mm² 95mm² 120mm² 150mm² 185mm² 240mm² 300mm² 9.2 6.2 3.7 3.2 1.5 1.1 0.82 0.59 0.45 0.38 0.34 0.3 0.27 0.18 Cross section mV/A/m 16 mm² 25mm² 35mm² 50mm² 70mm² 95mm² 120mm² 150mm² 185mm² 240mm² 300mm² 3.9 2.5 1.8 1.3 0.93 0.69 0.56 0.48 0.4 0.34 0.3 ) ‫جدول‬ ( 5 ‫جدول‬ ( 6 )
  • 60. 3 - ‫القصر‬ ‫تيار‬ ‫حساب‬ : calculation of short circuit current ‫بغرض‬ ‫وذلك‬ ‫الكهربائية‬ ‫التركيبات‬ ‫فى‬ ‫المختلفة‬ ‫النقاط‬ ‫عند‬ ‫القصر‬ ‫تيارات‬ ‫حساب‬ ‫يجب‬ :  ‫القطع‬ ‫سعة‬ ‫اختبار‬ breaking capacity ‫فصل‬ ‫اتمام‬ ‫يمكنها‬ ‫التى‬ ‫الوقاية‬ ‫لمهمات‬ ‫الفصل‬ ‫أثناء‬ ‫تتأثر‬ ‫أن‬ ‫بدون‬ ‫التغذية‬ .  ‫االنتقائية‬ ‫خاصية‬ ‫لتحقيق‬ ‫الالزمة‬ ‫الوقاية‬ ‫تشغيل‬ ‫تيارات‬ ‫اختبار‬ selectivity ‫لتالفى‬ ‫داع‬ ‫بدون‬ ‫األحمال‬ ‫بعض‬ ‫عن‬ ‫التغذية‬ ‫فصل‬ . ‫يلى‬ ‫كما‬ ‫الثالثى‬ ‫القصر‬ ‫تيار‬ ‫حساب‬ ‫يتم‬ ‫القطع‬ ‫سعة‬ ‫اختيار‬ ‫ولغرض‬ : Zt U Zt U c Is n S 05 . 1 .   ‫حيث‬ : - ‫الثالثى‬ ‫القصر‬‫لتيار‬‫العددية‬ ‫القيمة‬ : Is.c ‫ر‬‫للطو‬ ‫الكلية‬‫للمعاونة‬ ‫العددية‬ ‫القيمة‬ ‫القصر‬‫موقع‬‫حتى‬‫التغذية‬‫مصدر‬‫من‬ : Zt ‫حمل‬‫وجود‬‫عدم‬‫عند‬ ‫بالفولت‬ ‫المصدر‬‫اف‬‫ر‬‫ط‬‫ا‬‫عند‬‫ر‬‫الطو‬‫جهد‬ : Us ‫حمل‬‫وجود‬ ‫حالة‬‫فى‬ ‫المصدر‬‫اف‬‫ر‬‫ط‬‫ا‬ ‫عند‬‫ر‬‫الطو‬‫جهد‬ : Un
  • 61. ‫القصر‬ ‫حالة‬ ‫فى‬ ‫الكلية‬ ‫المعادلة‬ ‫حساب‬ ‫يجب‬ ‫فإنه‬ ‫بعاليه‬ ‫للمعادلة‬ ‫القصر‬ ‫تيار‬ ‫ولحساب‬ Zt ‫يلى‬ ‫كما‬ : - ‫الكلية‬ ‫المعادلة‬ ‫تشمل‬ Zt ‫التوزي‬ ‫قضبان‬ ‫أو‬ ‫التغذية‬ ‫وكابالت‬ ‫بالمصدر‬ ‫الخاصة‬ ‫المعاوقات‬ ‫مجموع‬ ‫ع‬ ‫ا‬ ‫دائرة‬ ‫مكونات‬ ‫من‬ ‫لكل‬ ‫والممانعات‬ ‫المقاومات‬ ‫حسابات‬ ‫يلى‬ ‫وفيما‬ ‫والتوصيل‬ ‫القطع‬ ‫ووحدات‬ ، ‫لقصر‬ ‫المنخفض‬ ‫الجهد‬ ‫دائرة‬ ‫جهة‬ ‫فى‬ ‫الخطأ‬ ‫يكون‬ ‫عندما‬ ‫وذلك‬ . ‫أ‬ ) ‫المتوسط‬ ‫الجهد‬ ‫ذو‬ ‫التغذية‬ ‫مصدر‬ : ‫مقاومة‬ ‫تهمل‬ Rs.c ‫التغذ‬ ‫محول‬ ‫قبل‬ ‫للمصدر‬ ‫الكائن‬ ‫المكافئة‬ ‫الممانعة‬ ‫حساب‬ ‫ويمكن‬ ‫للمصدر‬ ‫ية‬ ‫التالية‬ ‫المعادلة‬ ‫من‬ ‫القصر‬ ‫نقطة‬ ‫عند‬ ‫الجهد‬ ‫الى‬ ‫منسوب‬ XS.C(M.OHM) RS.C (M.OHM) US ( UOLTS) S.C(K.VA) 0.633 0.095 231 250.000 0.316 0.047 231 500.000
  • 62. ‫ب‬ ) ‫المنخفض‬ ‫الجهد‬ ‫تغذية‬ ‫محول‬ : Transformer ‫التالية‬ ‫الصيغة‬ ‫باستعمال‬ ‫المحول‬ ‫لمعاوقة‬ ‫العددية‬ ‫القيمة‬ ‫حساب‬ ‫يمكن‬ : c Us A V K Us c Zs . . . 3 . 2  ‫حيث‬ : ‫بالمللى‬‫المحول‬‫لمقاومة‬‫العددية‬‫القيمة‬ . ‫القصر‬‫نقطة‬‫عند‬‫الجهد‬‫الى‬‫منسوبة‬‫وم‬‫ا‬ : Zs.c ‫القصر‬‫نقطة‬‫عند‬‫حمل‬‫وجود‬ ‫عدم‬‫حالة‬‫فى‬‫التعادل‬‫وموصل‬‫ر‬‫الطو‬‫بين‬‫الجهد‬‫فرق‬ : Us ‫عنها‬‫ويعوض‬‫الخطا‬‫ناحية‬‫المقنن‬ ‫الجهد‬‫الى‬‫الكامل‬‫الحمل‬‫عند‬‫المحول‬‫فى‬‫الجهد‬‫هبوط‬‫نسبة‬ ( 0.04 ، 0.05 ، 0.06 :) - : Us.c ‫مبير‬‫ا‬‫فولت‬‫بالكيلو‬‫طوار‬‫ال‬‫ثالثى‬‫المحول‬‫قدرة‬ : - K.V.A: ‫والجدول‬ ‫التالى‬ ‫استرشادى‬ ‫يعطى‬ ‫قيما‬ ‫نة‬‫ر‬‫للمقا‬ ‫والممانعة‬ ‫للمحولت‬ ‫المختلفة‬ ‫القدرة‬ ‫منسوبة‬ ‫لجهة‬ ‫الجهد‬ ‫المنخفض‬ 380/220 ‫فولت‬ ‫وذلك‬ ‫فى‬ ‫حالة‬ ‫عدم‬ ‫ود‬‫ر‬‫و‬ ‫بيانات‬ ‫من‬ ‫الصانع‬ ( ‫جدول‬ 7 ) ‫يوضح‬ ‫قيم‬ ‫الممانعة‬ ‫والمقاومة‬ ‫للمحولت‬ ‫ويجب‬ ‫مالحظة‬ ‫نه‬‫ا‬ ‫فى‬ ‫حالة‬ ‫استخدام‬ ‫عدد‬ ‫من‬ ‫المحولت‬ ‫على‬ ‫ى‬‫التواز‬ ‫فيجب‬ ‫ن‬‫ا‬ ‫نقسم‬ ‫قيمة‬ ‫الممانعة‬ ‫للمحول‬ ‫الواحد‬ ‫على‬ ‫عدد‬ ‫المحولت‬ ‫للحصول‬ ‫على‬ Xs.c ‫لمجموعة‬ ‫المحولت‬ . ‫يمكن‬ ‫حساب‬ Rsc ‫من‬ ‫المعادلة‬ n I c Rs PCu 2 . 3  ‫حيث‬ Pcu : ‫بالوات‬‫النحاس‬‫فى‬‫الفقد‬ . ‫فإن‬‫السعة‬‫الكبيرة‬‫للمحولت‬‫وبالنسبة‬ Rs.c ‫إهمالها‬‫ويمكن‬ ‫صغيرة‬‫قيمة‬‫ذات‬‫تكون‬ .
  • 64. ‫جـ‬ ) ‫الدوائر‬ ‫قواطع‬ Breakers circuit ْ‫يرجعْالىْكتالوجاتْالمنتجْويمكنْإهمال‬ Xs.c ْ، Rs.c ْ‫فىْحالةْعدمْوجودْتفصيالت‬ . ‫اْفىْحالةْقواطعْالجهدْالمنخفضْاذاْلمْتكنْهناكْمعلوماتْمنْالم‬ْ‫وعموما‬ ْ‫نتجْيمكنْاعتبار‬ Rs.c ْ،ْ‫مهملة‬ Xs.c ْ‫فىْحدود‬ 0.15 ْ‫مللىْأرم‬ . ‫د‬ ) ‫والكابالت‬ ‫الموصالت‬ cables & conductors ْ‫يمكنْحسابْالمقاومة‬ Rs.c ْ‫بالمللىْأومْمنْالعالقةْالتالية‬ : Rsc A L   ‫حيث‬ L ،‫بالمتر‬ A ‫عند‬‫لومونيوم‬‫وال‬‫للنحاس‬‫النوعية‬‫المقاومة‬‫قيمة‬‫وتبلغ‬‫المربع‬‫بالملليمتر‬ 70ْ ‫كالتالى‬‫م‬ : = 21mm.ohm.mm2/m cu  = 33mm.ohm.m² AL  ‫الممانعة‬ Xs.c ‫الواحد‬‫ر‬‫للطو‬‫وم‬‫ا‬‫بالمللى‬ : - Xs.c = 0.07x L Xs.c = 0.15 x L ً‫معا‬‫للموصلين‬ ‫قطاب‬‫ال‬‫حادى‬‫ا‬‫للكابل‬ . ‫من‬‫قل‬‫ال‬‫للكابالت‬‫وبالنسبة‬ 25 ‫مم‬ 2 ‫المقاومة‬‫بقيم‬‫نة‬‫ر‬‫مقا‬‫الممانعة‬‫إهمال‬‫يمكن‬ .
  • 65. ‫هـ‬ ) ‫القضبان‬ : Bus bars ‫المقاومة‬ Rb ‫وتكون‬ L ‫و‬ ‫بالمتر‬ A ‫المربع‬ ‫بالملليمتر‬ ‫للنحاس‬ ‫النوعية‬ ‫المقاومة‬ ‫قيمة‬ ‫وتبلغ‬ 21 ‫مللى‬ . ‫أوم‬ . ‫مم‬ 2 / ‫م‬ ‫ولأللومونيوم‬ 33 ‫مللى‬ . ‫أوم‬ . ‫مم‬ 2 / ‫م‬ ‫الممانعة‬ Xb ( ‫بالمللى‬ . ‫أوم‬ = ) Xb = 0.15 x L ‫الصغير‬ ‫المقطع‬ ‫ذات‬ ‫عدا‬ ‫القضبان‬ ‫مقاومة‬ ‫إهمال‬ ً‫ا‬‫عموم‬ ‫ويمكن‬ . 6.7 Example For Calculation of Short Circuit Currents :- ‫القصر‬ ‫تيارات‬ ‫لحساب‬ ‫مثال‬ ‫يلى‬ ‫وفيما‬ [ ‫رقم‬ ‫تخطيطى‬ ‫رسم‬ ( 1 ] ) ‫أ‬ ) ‫المتوسط‬ ‫الجهد‬ : medium voltage ‫قيمة‬ ‫اهمال‬ ‫يمكن‬ R1 ‫لـ‬ ‫بالنسبة‬ X1 ‫قيمة‬ ‫حساب‬ ‫أردنا‬ ‫واذا‬ X1 ‫المنخفض‬ ‫الجهد‬ ‫الى‬ ‫منسوبة‬ Un = 380v ‫القطر‬ ‫دائرة‬ ‫قدرة‬ ‫وباعتبار‬ 500 ‫م‬ . ‫ف‬ . ‫قيمة‬ ‫تكون‬ ‫أ‬ X1 ‫التالى‬ ‫النحو‬ ‫على‬ : ( Us = 1.05Un ) ‫ب‬ ) ‫المحول‬ : Transformer ‫اهمال‬ ‫ويمكن‬ R2 ‫لقيمة‬ ‫بالنسبة‬ X2 ‫القصر‬ ‫دائرة‬ ‫لجهد‬ ‫المئوية‬ ‫النسبة‬ ‫قيمة‬ ‫تكون‬ Us.c ‫هى‬ 0.05 ‫جدول‬ ‫من‬ ‫وذلك‬ ( 7 ) ‫قيمة‬ ‫تصبح‬ ‫وعندئذ‬ X2 ‫يلى‬ ‫كما‬ : X1 +X2 = 0.32 + 7.96 = 8.28m.ohm A L   Ohm m X . 96 . 7 1000 05 . 0 ) 05 . 1 380 ( 2 2    
  • 66. ‫جـ‬ ) ‫الرئيسية‬ ‫التوزيع‬ ‫ولوحة‬ ‫المحول‬ ‫بين‬ ‫التوصيل‬ ‫قضبان‬ : Bus duct ‫حساب‬ ‫يمكن‬ R3 X3 ‫التالى‬ ‫النحو‬ ‫على‬ : X3 = 0.15 x 5 = 0.75 m.ohm ‫د‬ ) ‫الرئيسى‬ ‫القاطع‬ : Main circuit breaker ‫اهمال‬ ‫يمكن‬ ra ‫لـ‬ ‫بالنسبة‬ Xa ‫وتكون‬ : Xa = 0.15m. ohm ‫هـ‬ ) ‫التوزيع‬ ‫قضبان‬ : Bus bars Xb = 0.15 x 2 = 0.3m.ohm ‫و‬ ) ‫فرعى‬ ‫قاطع‬ : Branch circuit breaker ‫اهمال‬ ‫يمكن‬ Rs.c ‫لـ‬ ‫بالنسبة‬ Xs.c ‫وتكون‬ Xs.c = 0.15m.ohm ‫فرعي‬ ‫قواطع‬ ‫وثالث‬ ‫الرئيسى‬ ‫القاطع‬ ‫شاملة‬ ‫بأكملها‬ ‫التوزيع‬ ‫لوحة‬ ‫وممانعة‬ ‫مقاومة‬ ‫تكون‬ ‫وبذلك‬ ‫ة‬ ‫كما‬ ‫يلى‬ : ‫مهملة‬ ‫كمية‬ = R4 X4 = 0.6m.ohm ‫ز‬ ) ‫األلومونيوم‬ ‫التغذية‬ ‫كابل‬ Aluminum cable R5 X5 = 0.07 x 50 = 3.5m.ohm A L R   ohm m X R . 088 . 0 1200 5 21 3   A L   ohm m. 11 150 50 33   
  • 67. ‫ويكون‬‫الرسم‬‫فى‬‫اليها‬‫المشار‬‫المختلفة‬‫النقاط‬‫عند‬‫القصر‬ ‫ات‬‫ر‬‫تيا‬‫حساب‬‫ويمكن‬ ‫ا‬ ) ‫النقطة‬‫عند‬ ‫القصر‬‫تيار‬ (a) R1 + R2 = negligibly small X1 + X2 = 8.28m.ohm kA a c Is 28 82 . 27 28 . 8 05 . 1 220 ) ( .     ‫ب‬ ) ‫النقطة‬‫عند‬‫القصر‬‫تيار‬ (b) R1 + R2 + R3 = negligibly small X1 + X2 + X3 = 0.32 + 7.96 + 0.75 = 9.03m.ohm kA 26 51 . 25 03 . 9 05 . 1 220     ‫ج‬ ) ‫النقطة‬‫عند‬‫القصر‬ ‫تيار‬ (c) R1 + R2 + R3 + R4 = negligibly small X1 + X2 + X3 + X4 = 9.03 + 0.6 = 9.63m.ohm A k C c Is . 24 921 . 23 63 . 9 05 . 1 220 ) ( .     Isc(b)
  • 68. ‫د‬ ) ‫النقطة‬‫عند‬ ‫القصر‬‫تيار‬ (d) R1 + R2 + R3 + R4+ R5 = 0 + 0 + 0.088 + 0 + 11 = 11.088 X1 + X2 + X3 + X4 + X5 = 9.63 + 3.5 = 13.13 m.ohm      2 2 X R Zt    2 2 ) 13 . 13 ( ) 088 . 11 ( ohm m. 19 . 17 34 . 295 4 . 172 94 . 122    kA 17 44 . 13 19 . 17 05 . 1 220     Isc(d)
  • 69. 6.8 Example For Choice A Suitable Cable Cross Section Area For Load ‫مثال‬ : ‫على‬ ‫اختيار‬ ‫مقطع‬ ‫الكابل‬ ‫المناسب‬ ‫ألحد‬ ‫األحمال‬ ‫حسب‬ ‫الرسم‬ ‫التخطيطى‬ ‫رقم‬ ( 2 ) ‫محول‬ ‫قدرة‬ 500 k .V.A ‫جهد‬ 10500/380 volt ‫يغذى‬ ‫منشأ‬ ‫يبعد‬ ‫عنه‬ ‫بمسافة‬ 250 ‫متر‬ ‫مطلوب‬ ‫تصميم‬ ‫قطاع‬ ‫الكابل‬ ‫المناسب‬ ‫للحمل‬ ‫الكهربائى‬ ‫المغذى‬ ‫للمنشأ‬ . ‫التالية‬ ‫لألسسس‬ ‫طبقا‬ ‫التصميم‬ ‫يتم‬ : - ‫للكابل‬‫التيارية‬‫السعة‬ Current carrying capacity ‫الجهد‬‫هبوط‬‫قيمة‬ Voltage drop ‫المناسبة‬‫التصحيح‬‫معامالت‬ Correction factors ‫القصر‬‫ات‬‫ر‬‫تيا‬‫حسابات‬ Short circuit current ‫العوامل‬ ‫هذه‬ ‫لكل‬ ‫المناسب‬ ‫الكابل‬ ‫مقطع‬ ‫اختيار‬ ‫يتم‬ ‫ذلك‬ ‫وبعد‬ ‫للكابل‬ ‫التيارية‬ ‫السعة‬ 1 current carrying capacity : 760 380 3 10 500 3 3       U power In Ampere
  • 70. ‫يتم‬ ‫اختبار‬ ‫قطاع‬ ‫الكابل‬ ‫المناسب‬ ‫لهذا‬ ‫التيار‬ ‫من‬ ‫الجداول‬ ‫الخاصة‬ ‫بتحميل‬ ‫الكابال‬ ‫ت‬ ‫التى‬ ‫يتم‬ ‫اعدادها‬ ‫بواسطة‬ ‫الشركات‬ ‫المنتجة‬ ‫ونفرض‬ ‫قطاع‬ ‫مناسب‬ ‫وهو‬ 240 mm² ‫نجد‬ ‫أن‬ ‫التيار‬ ‫المناسب‬ ‫لهذا‬ ‫القطاع‬ ‫فى‬ ‫الجداول‬ ‫هو‬ 345 Ampere ‫على‬ ‫أساس‬ ‫أن‬ ‫الكابالت‬ ‫مدفونة‬ ‫باألرض‬ ‫ومسلحة‬ . Cable = ‫الحمل‬ ‫الكلى‬ / ‫الحمل‬ ‫الكهربائى‬ ‫للكابل‬ No of cables = * ً‫ا‬‫مبدئي‬ ‫نفترض‬ ‫عدد‬ 3 ‫كابل‬ ‫قطاع‬ ( 3 x240+120 mm²) 3 2 . 2 345 760   Amper cable I 254 3 . 253 3 / 760 /    ‫الجهد‬ ‫هبوط‬ ‫قيمة‬ ‫حساب‬ 2.Calculation of voltage drop: ‫التالية‬ ‫بالمعادلة‬ ‫الجهد‬ ‫هبوط‬ ‫قيمة‬ ‫حساب‬ ‫يمكن‬ L I mV V n c   
  • 71. ‫هبوط‬ ‫الجهد‬ ‫النوعى‬ ‫فى‬ ‫الكابل‬ ‫و‬‫ا‬ ‫الموصل‬ ‫بالمملى‬ ‫فولت‬ / ‫مبير‬‫ا‬ / ‫متر‬ ( ‫ج‬‫ر‬‫مد‬ ‫فى‬ ‫الجداول‬ ‫هبوط‬ ‫ال‬ ‫فولت‬ ) mV : ‫التيار‬ ‫التصميمى‬ ‫للكابل‬ ‫مبير‬‫باال‬ : In ‫طول‬ ‫الكابل‬ ‫بالمتر‬ : L 3 10 0.27x (= ‫قطاع‬‫الكابل‬ 240 ‫مم‬ 2 ) mV Vc = 0.27 254 10 3    ampere x 250 (meter) 2 . 17  volt 380 2 . 17 = ‫الجهد‬‫هبوط‬‫قيمة‬ / ‫المستخدم‬‫الكلى‬‫الجهد‬ = percentage of voltage drop * ‫وهذه‬ ‫النسبة‬ ‫لهبوط‬ ‫الجهد‬ ‫تعتبر‬ ‫عاليه‬ ‫نسبيا‬ ‫حيث‬ ‫ن‬‫ا‬ ‫النسبة‬ ‫المسموح‬ ‫بها‬ ‫هى‬ : = 2.5 % ‫قيمة‬‫ى‬‫ا‬ = 9.5 volt * ‫وباعادة‬ ‫التعويض‬ ‫فى‬ ‫معادلة‬ ‫هبوط‬ ‫الجهد‬ ‫بفرض‬ ‫ن‬‫ا‬ ‫قصى‬‫ا‬ ‫قيمة‬ ‫مسموح‬ ‫بها‬ ‫فى‬ ‫الهبوط‬ ‫هى‬ 9.5 ‫فولت‬ ‫فإننا‬ ‫نحصل‬ ‫من‬ ‫هذه‬ ‫المعادلة‬ ‫على‬ ‫قصى‬‫ا‬ ‫تيار‬ ‫تصميمى‬ ‫يؤدى‬ ‫الى‬ ‫هبوط‬ ‫جهد‬ ‫مناسب‬ ‫ل‬ ‫يتعدى‬ ‫ال‬ 2.5 % = 17.14 4.5% = L mV V I C n    3 10 140 250 27 . 0 10 5 . 9 3     n I Ampere
  • 72. * ‫قطاع‬ ‫الكابالت‬ ‫عدد‬ ‫حساب‬ ‫يمكن‬ 240 mm² ‫جهد‬ ‫هبوط‬ ‫تعطى‬ ‫والتى‬ ‫للتيار‬ ‫الجديدة‬ ‫للقيم‬ ‫طبقا‬ ‫مناسب‬ Cables No of cables = * ‫كابل‬ ‫لكل‬ ‫المقنن‬ ‫التيار‬ (In) ‫بعاليه‬ ‫الكابالت‬ ‫لعدد‬ ‫طبقا‬ ( 6 ‫كابالت‬ ) In = *** 3 – Application of correction factors :- ( ‫للكابالت‬ ‫التصحيح‬ ‫معامالت‬ ‫)تطبيق‬ a ) “ Ca “ ‫األرض‬ ‫سطح‬ ‫تحت‬ ‫مدفونة‬ ‫الكابالت‬ ‫أن‬ ‫حيث‬ ‫المحيط‬ ‫الوسط‬ ‫حرارة‬ ‫تأثير‬ ‫معامل‬ Ca = 1 ( ‫المرفقة‬ ‫الجداول‬ ‫من‬ ) b ) “ Cg” grouping factor ‫الكابالت‬ ‫تجميع‬ ‫معامل‬ ‫عدد‬ ‫كل‬ ‫فى‬ ‫طبقتين‬ ‫على‬ ‫الكابالت‬ ‫يتركب‬ 3 ‫الـ‬ ‫جداول‬ ‫فى‬ ‫وبالبحث‬ ‫كابالت‬ Cg ‫أن‬ ‫نجد‬ Cg = 0.7 * ‫للكابالت‬ ‫الكلى‬ ‫التصحيح‬ ‫معامل‬ “ Cf “ “Cf “ = Ca x Cg = 1 x0.7 = 0.7 ‫يلى‬ ‫كما‬ ‫للكابل‬ ‫التيارية‬ ‫السعة‬ ‫حساب‬ ‫يمكن‬ : ampere *** 6 4 . 5 140 760   Amp 126 6 760  In = 180 7 . 0 126    F B C I Iz
  • 73. ‫هى‬ ‫للكابل‬ ‫تيارية‬ ‫سعة‬ ‫أقصى‬ 180 A ‫قيمته‬ ‫تيار‬ ‫تصميم‬ ‫تم‬ ‫أنه‬ ‫وبما‬ 126 A ‫الواحد‬ ‫للكابل‬ ‫وهما‬ ‫الشرطين‬ ‫وتحقق‬ ‫مناسبة‬ ‫القيمة‬ ‫هذه‬ ‫اذن‬ : 1 – voltage drop 2 – (Iz) ( ‫للكابل‬ ‫التيارية‬ ‫السعة‬ ) ‫الكابل‬ ‫فى‬ ‫بمروره‬ ‫مسموح‬ ‫تيار‬ ‫أقصى‬ ‫قيمة‬ ‫وهى‬ . 4 – Calculation of short circuit currents: - :) ‫القصر‬ ‫تيارات‬ ‫)حساب‬ ‫لتيار‬ ‫المالئمة‬ ‫الكابل‬ ‫مقطع‬ ‫مساحة‬ ‫حساب‬ ‫يمكن‬ ‫ذلك‬ ‫بعد‬ ‫ثم‬ ، ‫القصر‬ ‫تيار‬ ‫حساب‬ ‫طريقة‬ ‫يلى‬ ‫وفيما‬ ‫القصر‬ ‫اآلتى‬ ‫نجد‬ ‫السابق‬ ‫التوضيحى‬ ‫الرسم‬ ‫الى‬ ‫وبالرجوع‬ : - ‫المتوسط‬ ‫الجهد‬ : - medium voltage a) ‫قيمة‬ ‫اهمال‬ ‫يمكن‬ R1 ‫لـ‬ ‫بالنسبة‬ X1 ‫المنخفض‬ ‫الجهد‬ ‫الى‬ ‫منسوبة‬ ‫قيمة‬ ‫حساب‬ ‫وعند‬ Un = 380 ‫قدرة‬ ‫وباعتبار‬ ‫القصر‬ ‫دائرة‬ 500 ‫م‬ . ‫ف‬ . ‫قيمة‬ ‫تكون‬ ‫أ‬ X1 ‫يلى‬ ‫كما‬ =0.32 m.ohm X1 = ‫المحول‬ : - b ) Transformer ‫اهمال‬ ‫يمكن‬ R2 ‫لقيمة‬ ‫بالنسبة‬ X2 ‫القصر‬ ‫دائرة‬ ‫لجهد‬ ‫المئوية‬ ‫النسبة‬ ‫قيمة‬ ‫وتكون‬ U.S.C ‫هى‬ 5 % m.ohm X2 = X1 + X2 = 15.92 + 0.32 = 16.24 m.ohm   92 . 15 500 05 . 0 05 . 1 380 2    3 2 10 500 . ) 05 . 1 380 (   vA k
  • 74. C ) Low voltage cable : ‫للمنشا‬‫يع‬‫ز‬‫التو‬ ‫ولوحة‬‫المحول‬‫بين‬‫الواصلة‬‫المنخفض‬‫الجهد‬‫كابالت‬   ohm m mm m A L . 22 87 . 21 340 250 21 2      ‫المصرى‬‫للكود‬ ‫طبقا‬‫ى‬‫التواز‬‫على‬‫الموصلة‬‫الكابالت‬‫عدد‬‫على‬‫الناتجة‬‫المقاومة‬‫قسمة‬‫يتم‬ ‫حيث‬ 66 . 3 6 22  Xs.c = 0.07 x 250 (m) = 17.5 m.ohm D ) Main circuit breaker ‫المنخفض‬‫للجهد‬‫التوزيع‬‫للوحة‬‫ئيسى‬‫ر‬‫ال‬ ‫القاطع‬ ‫اهمال‬‫يمكن‬ Ra ‫ل‬‫بالنسبة‬ Xa Xa = 0.15m.oh E) Bus bars: ‫يع‬‫ز‬‫التو‬‫قضبان‬ ‫اهمال‬‫يمكن‬ Rb ‫ل‬‫بالنسبة‬ Xb ‫ات‬‫ر‬‫البا‬‫طول‬‫بفرض‬ 3 m Xb = 0.15 x 3 = 0.45 m.ohm * Short circuit impendence:- Zt =             2 3 2 1 2 2 1 ... ... R R R X X =    2 2 45 . 0 15 . 0 5 . 17 24 . 16 66 . 3     5 . 34 1192 1179 39 . 13    KA Zt 7 5 . 34 231 05 . 1 220    Is.c = 7K.A ‫عند‬ ‫لوحة‬ ‫التوزيع‬ ‫ئيسية‬‫ر‬‫ال‬ ‫للمبنى‬ R/6cable = m.ohm = m.ohm
  • 75. ‫قيمة‬ ‫وبتطبيق‬ current S.c ‫التالية‬ ‫المعادلة‬ ‫فى‬ 90º ‫عند‬ q = 8.6 x Is.c Where q = cross section area in mm² t = time in sec . 1 sec ‫بـ‬ ‫الزمن‬ ‫عن‬ ‫وبالتعويض‬ Q = 8.6x 7 = 60.2 ~ 61 mm² ‫هو‬ ‫القصر‬ ‫لتيار‬ ‫المناسب‬ ‫الكابل‬ ‫قطاع‬ ‫يكون‬ ‫وبذلك‬ 70 mm² ‫النتيجة‬ ‫لهذه‬ ‫قياسى‬ ‫مقطع‬ ‫أقرب‬ ‫وهو‬ ( ‫بين‬ ‫للعالقة‬ ‫بيانى‬ ‫رسم‬ ‫مرفق‬ t,q,Is.c ) ‫وال‬ ‫التيارية‬ ‫السعة‬ ‫يالئم‬ ‫اختياره‬ ‫تم‬ ‫الذى‬ ‫الكابل‬ ‫قطاع‬ ‫أن‬ ‫يتضح‬ ‫سبق‬ ‫ما‬ ‫كل‬ ‫على‬ ‫وبناءا‬ ‫الجهد‬ ‫هبوط‬ ‫وهو‬ 240 mm² ‫القصر‬ ‫تيارات‬ ‫لتحمل‬ ‫أيضا‬ ‫مناسب‬ ‫عدد‬ ‫اختيار‬ ‫يتم‬ 6 ‫قطاع‬ ‫كابالت‬ 120mm² + 240 × 3 ‫بعاليه‬ ‫المنشأ‬ ‫لتغذية‬ ‫منخفض‬ ‫جهد‬
  • 77.
  • 78. 7.1 general precautions for cable installations 1 - ‫الكابالت‬‫تركيب‬‫فى‬‫عامة‬‫احتياطات‬  ‫يجب‬ ‫اعاة‬‫ر‬‫م‬ ‫تى‬ ‫آ‬ ‫ال‬ ‫فى‬ ‫تركيب‬ ‫الكابالت‬ ‫بصفة‬ ‫عامة‬ : -  ‫يجب‬ ‫ن‬‫ا‬ ‫اعى‬‫ر‬‫ي‬ ‫ن‬‫ا‬ ‫تكون‬ ‫لوان‬‫ا‬ ‫كل‬ ‫الكابالت‬ ‫موحدة‬ ‫لكل‬ ‫طور‬ “phase” ‫ولخط‬ ‫التعادل‬ Neutral ‫ولخط‬ ‫رضى‬‫ال‬ Earth .  ‫يجب‬ ‫فحص‬ ‫جميع‬ ‫الكابالت‬ ‫من‬ ‫حيث‬ ‫النوع‬ ‫والجودة‬ ‫والمقطع‬ ‫واختبار‬ ‫درجة‬ ‫العزل‬ ‫فى‬ ‫الموقع‬ ‫قبل‬ ‫التركيب‬ ، ‫ويمكن‬ ‫ال‬ ‫تفاء‬‫ك‬ ‫بشهادات‬ ‫اختبار‬ ‫العزل‬ ‫فى‬ ‫المصنع‬ ‫مع‬ ‫اعاة‬‫ر‬‫م‬ ‫كد‬‫التا‬ ‫من‬ ‫عدم‬ ‫تلفها‬ ‫ثناء‬‫ا‬ ‫النقل‬ ‫و‬‫ا‬ ‫التخزين‬ .  ‫اعى‬‫ر‬‫ي‬ ‫عدم‬ ‫تركيب‬ ‫الكابالت‬ ‫الخاصة‬ ‫بتركيبات‬ ‫باإلنارة‬ ‫و‬‫ا‬ ‫القوى‬ ‫التى‬ ‫تغذى‬ ‫من‬ ‫جهود‬ ‫مختلفة‬ ( ‫خفيف‬ – ‫منخف‬ ‫ض‬ – ‫متوسط‬ ) ‫فى‬ ‫نفس‬ ‫المواسير‬ ‫و‬‫ا‬ ‫ى‬‫المجار‬ ‫ويجب‬ ‫ن‬‫ا‬ ‫تكون‬ ‫توصيالت‬ ‫كل‬ ‫جهد‬ ‫مستقلة‬ ‫بمواسيرها‬ ‫وعلب‬ ‫إتصالها‬ .  ‫اعى‬‫ر‬‫ي‬ ‫عند‬ ‫استخدام‬ ‫المواسير‬ ‫الصلب‬ ‫وفى‬ ‫حالة‬ ‫التيار‬ ‫المتردد‬ ‫تركيب‬ ‫موصل‬ ‫الطور‬ ‫وموصل‬ ‫التعادل‬ ‫فى‬ ‫حالة‬ ‫ال‬ single phase ‫وموصالت‬ ‫طوار‬‫ال‬ ‫وموصل‬ ‫التعادل‬ ‫فى‬ ‫حالة‬ ‫ال‬ ( 3 -phase) ‫داخل‬ ‫ماسورة‬ ‫واحدة‬ ‫ول‬ ‫ينطبق‬ ‫هذا‬ ‫فى‬ ‫حالت‬ ‫المواسير‬ ‫البالستيك‬ .  ‫اعى‬‫ر‬‫ي‬ ‫فى‬ ‫توصيل‬ ‫مخارج‬ ‫وحدات‬ ‫اإلضاءة‬ ‫وما‬ ‫يماثلها‬ ‫والتى‬ ‫تغذى‬ ‫من‬ ‫حد‬‫ا‬ ‫طوار‬‫ا‬ ‫التيار‬ ‫وخط‬ ‫التعادل‬ ‫ن‬‫ا‬ ‫يتصل‬ ‫خط‬ ‫التعادل‬ ‫مباشرة‬ ‫بوحدة‬ ‫اإلضاءة‬ ‫ويتصل‬ ‫سلك‬ ‫الطور‬ ‫بها‬ ‫عن‬ ‫طريق‬ ‫المفتاح‬ .  ‫يجب‬ ‫ن‬‫ا‬ ‫تنتهى‬ ‫جميع‬ ‫اف‬‫ر‬‫ط‬‫ا‬ ‫الكابالت‬ ‫التى‬ ‫يزيد‬ ‫مقطعها‬ ‫عن‬ 3 ‫مم‬ 2 ( ‫بالكوس‬ ) ‫الخاص‬ ‫بتوصيلها‬ ( ‫مان‬‫لال‬ ) ‫جهزة‬‫بال‬ .  ‫يجب‬ ‫ن‬‫ا‬ ‫تركب‬ ‫دوائر‬ ‫إنارة‬ ‫ء‬‫ى‬‫الطوار‬ ‫فى‬ ‫ات‬‫ر‬‫مسا‬ ‫مستقلة‬ ‫عن‬ ‫ات‬‫ر‬‫مسا‬ ‫دوائر‬ ‫اإلنارة‬ ‫العادية‬ .  ‫يجب‬ ‫ل‬‫ا‬ ‫يقل‬ ‫قطاع‬ ‫موصالت‬ ‫خطوط‬ ‫القوى‬ ‫عن‬ 3 ‫مم‬ 2 .  ‫يجب‬ ‫ن‬‫ا‬ ‫تكون‬ ‫سالك‬‫ال‬ ‫و‬‫ا‬ ‫الكابالت‬ ‫المستعملة‬ ‫بدون‬ ‫وصالت‬ ‫بين‬ ‫ى‬‫ا‬ ‫مخرجين‬ ‫و‬‫ا‬ ‫فيما‬ ‫بين‬ ‫المخرج‬ ‫وصندوق‬ ‫اإلتصال‬ ‫وي‬ ‫حظر‬ ‫عمل‬ ‫وصالت‬ ‫للكابالت‬ ‫سالك‬‫وال‬ ‫ال‬ ‫فى‬ ‫صناديق‬ ‫اإلتصال‬ .
  • 79. 2 - ‫األرضية‬ ‫الكابالت‬ ‫تركيب‬ ‫إحتياطات‬  ‫يفضل‬ ‫تركيب‬ ‫الكابالت‬ ‫رضية‬‫ال‬ ‫بطريقة‬ ‫الدفن‬ ‫المباشر‬ ‫فى‬ ‫رض‬‫ال‬ ‫اعى‬‫ر‬‫وت‬ ‫القواعد‬ ‫الت‬ ‫الية‬ ‫عند‬ ‫التركيب‬ :  ‫تمديد‬ ‫الكابالت‬ ‫رضية‬‫ال‬ ‫فى‬ ‫اتها‬‫ر‬‫مسا‬ ‫تحت‬ ‫الساحات‬ ‫المرصوفة‬ ‫و‬‫ا‬ ‫تقاطع‬ ‫الطرق‬ ‫داخل‬ ‫مواس‬ ‫ير‬ ‫بالستيك‬ ‫من‬ ‫النوع‬ ‫الثقيل‬ ‫و‬‫ا‬ ‫مواسير‬ ‫صلب‬ ‫يتم‬ ‫حمايتها‬ ‫جيدا‬ ‫ضد‬ ‫الصدا‬ .  ‫تركيب‬ ‫كابالت‬ ‫الجهد‬ ‫المنخفض‬ ‫داخل‬ ( ‫نشات‬‫ر‬‫ت‬ ) ‫بعمق‬ ‫ل‬ ‫يقل‬ ‫عن‬ 80 ‫سم‬ ‫ما‬‫ا‬ ‫كابالت‬ ‫الجهد‬ ‫المتوسط‬ ‫فتركب‬ ‫على‬ ‫عمق‬ ‫ل‬ ‫يقل‬ ‫عن‬ 1 ‫متر‬ ‫من‬ ‫منسوب‬ ‫سطح‬ ‫رض‬‫ال‬ .  ‫إذا‬ ‫إقتضت‬ ‫رة‬‫و‬‫الضر‬ ‫تركيب‬ ‫الكابالت‬ ‫فى‬ ‫طبقات‬ ‫ثر‬‫ك‬‫ا‬ ‫من‬ ‫طبقة‬ ‫واحدة‬ ‫فى‬ ‫ات‬‫ر‬‫مسا‬ ‫متقاطع‬ ‫ة‬ ‫يتم‬ ‫الفصل‬ ‫بين‬ ‫الطبقات‬ ‫المختلفة‬ ‫و‬‫ا‬ ‫الكابالت‬ ‫المتقاطعة‬ ‫بطبقة‬ ‫رملية‬ ‫بسمك‬ ‫ل‬ ‫يقل‬ ‫عن‬ 10 ‫سم‬ ‫وفى‬ ‫هذه‬ ‫الحالة‬ ‫يتم‬ ‫تركيب‬ ‫كابالت‬ ‫الجهد‬ ‫المتوسط‬ ‫فى‬ ‫الطبقات‬ ‫السفلية‬ ‫على‬ ‫ل‬‫ا‬ ‫يقل‬ ‫منسوب‬ ‫على‬‫ا‬ ‫طبق‬ ‫ة‬ ‫عن‬ 60 ‫سم‬ ‫تحت‬ ‫منسوب‬ ‫رض‬‫ال‬ ‫الطبيعية‬ .  ‫يجهز‬ ‫قاع‬ ‫الخندق‬ ‫قبل‬ ‫رمى‬ ‫الكابالت‬ ‫بطبقة‬ ‫من‬ ‫الرمل‬ ‫الناعم‬ ‫بسمك‬ 10 ‫سم‬ ‫ثم‬ ‫تمدد‬ ‫الكابالت‬ ‫وتغطى‬ ‫بطبقة‬ ‫خرى‬‫ا‬ ‫من‬ ‫الرمل‬ ‫الناعم‬ ‫بسمك‬ 10 ‫سم‬ ‫وتوضع‬ ‫بعد‬ ‫ذلك‬ ‫بالطات‬ ‫خرسانية‬ ‫سمك‬ 5 ‫سم‬ ‫فوق‬ ‫هذه‬ ‫الطبقة‬ ‫الرملية‬ ‫وبطول‬ ‫مسار‬ ‫الكابل‬ ‫ثم‬ ‫يردم‬ ‫الخندق‬ ‫ويدك‬ ‫بعد‬ ‫وضع‬ ‫شريط‬ ‫تحذير‬ ‫صفر‬‫ا‬ ‫توب‬‫مك‬ ‫عليه‬ ‫نوع‬ ‫الكابل‬ ‫بطول‬ ‫المسار‬ ‫على‬ ‫عمق‬ 30 ‫سم‬ ‫من‬ ‫منسوب‬ ‫رض‬‫ال‬ ‫الطبيعية‬ ‫كالشكل‬ ‫رقم‬ ( 24 ) .
  • 80. ‫ال‬ ‫بين‬ ‫الفاصلة‬ ‫المسافات‬ ‫على‬ ‫المحافظة‬ ‫واحد‬ ‫مسار‬ ‫فى‬ ‫كابل‬ ‫من‬ ‫أكثر‬ ‫تمديد‬ ‫عند‬ ‫يراعى‬ ‫على‬ ‫كابالت‬ ‫المصرى‬ ‫للكود‬ ‫طبقا‬ ‫التالى‬ ‫النحو‬ : - ‫م‬ ‫الكابالت‬‫نوع‬ ‫الفاصلة‬‫المسافة‬‫مقدار‬ 1 ‫كابل‬ ‫جهد‬ ‫منخفض‬ ‫بجانب‬ ‫كابل‬ ‫تليفونات‬ 30 ‫سم‬ ‫على‬ ‫قل‬‫ال‬ 2 ‫كابل‬ ‫منخفض‬ ‫بجانب‬ ‫كابل‬ ‫تحكم‬ ( ‫كنترول‬ ) ‫بدون‬ ‫مسافة‬ ‫فاصلة‬ 3 ‫كابل‬ ‫تحكم‬ ‫بجانب‬ ‫كابل‬ ‫تحكم‬ ‫بدون‬ ‫مسافة‬ ‫فاصلة‬ 4 ‫كابل‬ ‫جهد‬ ‫منخفض‬ ‫بجانب‬ ‫كابل‬ ‫جهد‬ ‫منخفض‬ ‫قطر‬ ‫الكابل‬ ‫وبحد‬ ‫دنى‬‫ا‬ 1 ‫سم‬ ‫ونستعمل‬ ‫فواصل‬ ‫بين‬ ‫الكابالت‬ ‫كل‬ 1 - 1.5 ‫متر‬ 5 ‫كابل‬ ‫جهد‬ ‫منخفض‬ ‫بجانب‬ ‫كابل‬ ‫جهد‬ ‫متوسط‬ 15 ‫سم‬ ‫ويفصل‬ ‫بينهما‬ ‫بقوالب‬ ‫توضع‬ ً‫سيا‬‫ا‬‫ر‬ ‫على‬ ‫جانبها‬ 6 ‫كابل‬ ‫جهد‬ ‫متوسط‬ ‫بجانب‬ ‫كابل‬ ‫جهد‬ ‫متوسط‬ ‫اآلتى‬ ‫يراعى‬ ‫األرضية‬ ‫الكابالت‬ ‫لمرور‬ ‫المواسير‬ ‫استخدام‬ ‫عند‬ : ‫أ‬ - ‫سمك‬ ‫فرشة‬ ‫من‬ ‫مكونة‬ ‫رملية‬ ‫طبقة‬ ‫فى‬ ‫المواسير‬ ‫تدفن‬ 10 ‫السمك‬ ‫بنفس‬ ‫وغطاء‬ ‫سم‬ ‫ب‬ - ‫وعم‬ ‫المواسير‬ ‫اتجاه‬ ‫تغيير‬ ‫عند‬ ‫تفتيش‬ ‫بغرف‬ ‫المسار‬ ‫ويزود‬ ‫فقط‬ ‫مستقيمة‬ ‫مسارات‬ ‫فى‬ ‫المواسير‬ ‫تركب‬ ً‫ا‬‫وم‬ ‫كل‬ ‫التفتيش‬ ‫غرف‬ ‫تكون‬ 30 ‫األقل‬ ‫على‬ ‫متر‬ . ‫جـ‬ - ‫قطر‬ ‫مجلفن‬ ‫شد‬ ‫بسلك‬ ‫المواسير‬ ‫تزود‬ 3 ‫الى‬ ‫الماسورة‬ ‫طرفى‬ ‫خارج‬ ‫يمتد‬ ‫مم‬ 50 ‫األقل‬ ‫على‬ ‫سم‬ : ‫د‬ - ‫كابالت‬ ‫أى‬ ‫سحب‬ ‫قبل‬ ‫الداخل‬ ‫من‬ ‫بعناية‬ ‫المواسير‬ ‫تنظيف‬ .
  • 81. * ‫تركيب‬ ‫الكابالت‬ ‫األرضية‬ ‫المسلحة‬ ‫فى‬ ‫األرض‬ ‫بدون‬ ‫مواسير‬ : ‫أ‬ - ‫يراعى‬ ‫عند‬ ‫تركيب‬ ‫الكابالت‬ ‫فى‬ ‫األرض‬ ‫التحقق‬ ‫من‬ ‫أن‬ ‫التربة‬ ‫ال‬ ‫تحتوى‬ ‫على‬ ‫أمالح‬ ‫أو‬ ‫مواد‬ ‫كيماوية‬ ‫تسبب‬ ‫تآكل‬ ‫الطبقات‬ ‫الخارجية‬ ‫للكابل‬ . ‫ب‬ - ‫واذا‬ ‫كانت‬ ‫التربة‬ ‫تحتوى‬ ‫على‬ ‫أمالح‬ ‫أو‬ ‫مواد‬ ‫كيماوية‬ ‫يراعى‬ ‫استعمال‬ ‫كابالت‬ ‫مغ‬ ‫لفة‬ ‫بالبالستيك‬ ‫المقاوم‬ ‫لعوامل‬ ‫التآكل‬ . * ‫تركيب‬ ‫الكابالت‬ ‫األرضية‬ ‫المسلحة‬ ‫داخل‬ ‫مواسير‬ ‫حديد‬ ‫أو‬ ‫فخار‬ ‫أو‬ ‫أسمنت‬ ‫تحت‬ ‫األر‬ ‫ض‬ : ‫أ‬ - ‫ال‬ ‫يركب‬ ‫أكثر‬ ‫من‬ ‫كابل‬ ‫واحد‬ ‫داخل‬ ‫ماسورة‬ ‫واحدة‬ . ‫ب‬ - ‫يكون‬ ‫القطر‬ ‫الداخلى‬ ‫للماسورة‬ ‫أكبر‬ ‫من‬ ‫القطر‬ ‫الخارجى‬ ‫للكابل‬ ‫بما‬ ‫ال‬ ‫يقل‬ ‫عن‬ 4 ‫سم‬ . ‫جـ‬ - ‫بعد‬ ‫االنتهاء‬ ‫من‬ ‫تركيب‬ ‫المواسير‬ ‫والردم‬ ‫عليها‬ ‫تسحب‬ ‫الكابالت‬ ‫داخل‬ ‫المواسير‬ ‫بواسطة‬ ‫شدادات‬ ‫من‬ ‫الصلب‬ ‫مع‬ ‫العناية‬ ‫التامة‬ ‫بعدم‬ ‫تعريض‬ ‫الكابل‬ ‫إلجهادات‬ ‫ناتجة‬ ‫من‬ ‫قو‬ ‫ة‬ ‫شد‬ ‫أو‬ ‫ثنى‬ ‫زائدة‬ ‫قد‬ ‫تؤثر‬ ‫على‬ ‫العزل‬ ‫أو‬ ‫على‬ ‫الطبقات‬ ‫الواقية‬ ‫ويحسن‬ ‫تغطية‬ ‫السطح‬ ‫الخارجى‬ ‫للكابل‬ ‫بمسحوق‬ ‫بودرة‬ ‫التلك‬ ‫ليسهل‬ ‫سحبه‬ ‫داخل‬ ‫المواسير‬ .
  • 82. 7-3 colour code ‫ن‬ ‫ظام‬ ‫لوان‬‫اال‬ ‫لتمييز‬ ‫قطاب‬‫اال‬ : ‫يجب‬ ‫تمييز‬ ‫الكابالت‬ ‫نة‬‫ر‬‫الم‬ ‫ذات‬ ‫الموصل‬ ‫الواحد‬ ‫وكذا‬ ‫جميع‬ ‫موصالت‬ ‫الكابالت‬ ‫غير‬ ‫نة‬‫ر‬‫الم‬ ‫سواء‬ ‫كانت‬ ‫مزدوجة‬ ‫و‬‫ا‬ ‫متعددة‬ ‫الموصالت‬ ‫المستخدمة‬ ‫فى‬ ‫التوصيالت‬ ‫الكهربائية‬ ‫الثابتة‬ ‫وذلك‬ ‫على‬ ‫امتداد‬ ‫طولها‬ ‫و‬‫ا‬ ‫عند‬ ‫نهايتها‬ ‫عل‬ ‫ى‬ ‫قل‬‫ال‬ ‫باستعمال‬ ‫طريقة‬ ‫مناسبة‬ ‫كما‬ ‫يلى‬ : 1 – ‫استخدام‬ ‫لوان‬‫ا‬ ‫موصالت‬ ‫الكابالت‬ ‫لة‬‫و‬‫المعز‬ ‫بالكاوتشوك‬ ‫لة‬‫و‬‫والمعز‬ ‫بالبالستيك‬ ‫طبقا‬ ‫للجدول‬ ‫رقم‬ ( 9 ) ‫و‬‫ا‬ ‫باستخدام‬ ‫ائط‬‫ر‬‫ش‬ ‫و‬‫ا‬ ‫جلب‬ ‫و‬‫ا‬ ‫اص‬‫ر‬‫ق‬‫ا‬ ‫عند‬ ‫النهايات‬ ‫لوان‬‫بال‬ ‫المناسبة‬ ‫ة‬‫ر‬‫المذكو‬ ‫بالجدول‬ . 2 - ‫ترقيم‬ ‫موصالت‬ ‫الكابالت‬ ‫المسلحة‬ ‫لة‬‫و‬‫والمعز‬ ‫بالبالستيك‬ (P.V.C) ‫كبديل‬ ‫للطريقة‬ ‫المبينة‬ ‫فى‬ ‫الفقرة‬ ( 1 ) ‫ويشترط‬ ‫تخصيص‬ ‫رقام‬‫ال‬ ( 1 ، 2 ، 3 ) ‫لموصالت‬ ‫طوار‬‫ال‬ ‫الثالثة‬ ‫قم‬‫ر‬‫و‬ ‫صفر‬ ‫لموصل‬ ‫التعادل‬ ‫قم‬‫ر‬‫و‬ ( 4 ) ‫للموصل‬ ‫ذو‬ ‫الغرض‬ ‫الخاص‬ .