SlideShare a Scribd company logo
1 of 4
Download to read offline
ANC-100e
Ethernet to DH+ Adapter
RSLinx Classic Configuration
This document provides information to configure RSLinx Classic to communicate with a
DH+ network from a computer using an ANC-100e Ethernet to Data Highway Plus
adapter.
Note: Before proceeding, make sure
 Network adapter is correctly configured to access ANC-100e
 ANC-100e is connected to the computer or Ethernet network and DH+ network
(Refer to appendix for Connections instructions and more information)
1. Open “RSLinx Classic”
2. Click on “Communications” menu
3. Click on “Configure Drivers”
2
ANC-100e
Ethernet to DH+ Adapter
4. Select “Remote Devices via Linx Gateway” from the Drop down list
5. Click on “Add New” Button
6. Enter the name for the driver or use the default name
7. Click “OK”
8. Enter the IP address of ANC-100e in the “Server’s IP Address or hostname:”
field
(Default is 192.168.137.2)
9. Click “OK”
3
ANC-100e
Ethernet to DH+ Adapter
10.Verify that the Driver is “Running”
11.Click on “Close” button
12.Open “RSWho” window
13.Click the checkbox to activate “Autobrowse” option
14.Double click on the driver element (In our example is TCP-1) to start browsing
the ANC-100e. During browsing, you will notice that more elements appear in a
branch fashion
15.Keep browsing until you reach “CH A, Data Highway plus”
All the devices connected to the same DH+ network as the ANC-100e will
appear here
4
ANC-100e
Ethernet to DH+ Adapter
Appendix
ANC-100e DH+ connection
There are 2 ways to connect to the DH+ network.
- Connect to Processor’s 3-pin connector: Daisy chain a cable from the last DH+
node to the connector of ANC-100e. Polarity of blue and clear cables is
irrelevant, as it is auto-detected by ANC-100e
- Connect to DH+ Programming Terminal on processor by using the ANC-100e
Mini-Din Programming Cable
Connect the DH+ cable to ANC-100e and then connect to your Ethernet network or a
free Ethernet port on your computer.
When the unit turns on, the Ethernet LED blinks several times.
Note: if AUTO Baud rate and AUTO DH+ Node options are active in ANC-100e,
the device will automatically configure the correct DH+ network speed and find a
free DH+ node number to use as its own address. So you don’t need any
configuration to start programming DH+ processor.
The ANC-100e DH+ LED blinks every 3 seconds if it is associated with the DH+
network and nothing is being transmitted on the DH+ link. When DH+ data exchange
takes place, the LED will indicate this by blinking rapidly upon transmitting/receiving a
valid DH+ packet. DH+ LED will remain off if the DH+ network is not connected or
there are no devices on the connected network.
About RSWho window and AutoBrowse option
RSLinx “Autobrowse” option is good to initially discover all active nodes on a particular
DH+ network quickly and easily, however, because of the extra traffic this feature
generates, it is recommended to have the “Autobrowse” checkbox unchecked in the
production environment.
For more information about settings and other options, please refer to ANC-100e User
Manual.

More Related Content

Similar to ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1)

Esp8266 wi fi_module_quick_start_guide_v_1.0.4
Esp8266 wi fi_module_quick_start_guide_v_1.0.4Esp8266 wi fi_module_quick_start_guide_v_1.0.4
Esp8266 wi fi_module_quick_start_guide_v_1.0.4Melvin Gutiérrez Rivero
 
Siemens PXC Controller Series Part-2
Siemens PXC Controller Series Part-2Siemens PXC Controller Series Part-2
Siemens PXC Controller Series Part-2CONTROLS & SYSTEMS
 
NMS TX4000
NMS TX4000NMS TX4000
NMS TX4000savomir
 
C4 L6000 Eth Operation Manual
C4 L6000 Eth Operation ManualC4 L6000 Eth Operation Manual
C4 L6000 Eth Operation Manualguest9fe343e
 
Supportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docx
Supportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docxSupportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docx
Supportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docxpicklesvalery
 
C4 L5200 Eth Operation Manual
C4 L5200 Eth Operation ManualC4 L5200 Eth Operation Manual
C4 L5200 Eth Operation Manualguest9fe343e
 
Ifma av toolevent 12-06-14_creston
Ifma av toolevent 12-06-14_crestonIfma av toolevent 12-06-14_creston
Ifma av toolevent 12-06-14_crestonMuriel Walter
 
Quick Installation Guide EnGenius EAP900H
Quick Installation Guide EnGenius EAP900H Quick Installation Guide EnGenius EAP900H
Quick Installation Guide EnGenius EAP900H EnGenius Europe
 
Adtran 1200167L1
Adtran 1200167L1Adtran 1200167L1
Adtran 1200167L1savomir
 
IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...
IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...
IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...Dweapons Art
 
Webinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLE
Webinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLEWebinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLE
Webinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLENetgear Italia
 
Videoconferencing Technology
Videoconferencing TechnologyVideoconferencing Technology
Videoconferencing TechnologyVideoguy
 

Similar to ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1) (20)

Voice controlled home appliances
Voice controlled home appliancesVoice controlled home appliances
Voice controlled home appliances
 
Esp8266 wi fi_module_quick_start_guide_v_1.0.4
Esp8266 wi fi_module_quick_start_guide_v_1.0.4Esp8266 wi fi_module_quick_start_guide_v_1.0.4
Esp8266 wi fi_module_quick_start_guide_v_1.0.4
 
Siemens PXC Controller Series Part-2
Siemens PXC Controller Series Part-2Siemens PXC Controller Series Part-2
Siemens PXC Controller Series Part-2
 
NMS TX4000
NMS TX4000NMS TX4000
NMS TX4000
 
En qig tew-p21_g
En qig tew-p21_gEn qig tew-p21_g
En qig tew-p21_g
 
C4 L6000 Eth Operation Manual
C4 L6000 Eth Operation ManualC4 L6000 Eth Operation Manual
C4 L6000 Eth Operation Manual
 
Supportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docx
Supportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docxSupportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docx
Supportive Security Policies in SOHOTopic SUPPORTIVE SECURI.docx
 
CentralizedSerialWP
CentralizedSerialWPCentralizedSerialWP
CentralizedSerialWP
 
Qig di 604
Qig di 604Qig di 604
Qig di 604
 
C4 L5200 Eth Operation Manual
C4 L5200 Eth Operation ManualC4 L5200 Eth Operation Manual
C4 L5200 Eth Operation Manual
 
Ifma av toolevent 12-06-14_creston
Ifma av toolevent 12-06-14_crestonIfma av toolevent 12-06-14_creston
Ifma av toolevent 12-06-14_creston
 
Quick Installation Guide EnGenius EAP900H
Quick Installation Guide EnGenius EAP900H Quick Installation Guide EnGenius EAP900H
Quick Installation Guide EnGenius EAP900H
 
Adtran 1200167L1
Adtran 1200167L1Adtran 1200167L1
Adtran 1200167L1
 
GREAT MINDS
GREAT MINDSGREAT MINDS
GREAT MINDS
 
IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...
IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...
IEEE Paper Implementation of Local Area Digital Audio Broadcasting System upo...
 
Dvbshop
DvbshopDvbshop
Dvbshop
 
Webinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLE
Webinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLEWebinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLE
Webinar NETGEAR - WiFi 11AC gestito con il controller virtuale ENSEMBLE
 
Lightspeed ii-manual-2012-jan
Lightspeed ii-manual-2012-janLightspeed ii-manual-2012-jan
Lightspeed ii-manual-2012-jan
 
IP VS STL
IP VS STLIP VS STL
IP VS STL
 
Videoconferencing Technology
Videoconferencing TechnologyVideoconferencing Technology
Videoconferencing Technology
 

ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1)

  • 1. ANC-100e Ethernet to DH+ Adapter RSLinx Classic Configuration This document provides information to configure RSLinx Classic to communicate with a DH+ network from a computer using an ANC-100e Ethernet to Data Highway Plus adapter. Note: Before proceeding, make sure  Network adapter is correctly configured to access ANC-100e  ANC-100e is connected to the computer or Ethernet network and DH+ network (Refer to appendix for Connections instructions and more information) 1. Open “RSLinx Classic” 2. Click on “Communications” menu 3. Click on “Configure Drivers”
  • 2. 2 ANC-100e Ethernet to DH+ Adapter 4. Select “Remote Devices via Linx Gateway” from the Drop down list 5. Click on “Add New” Button 6. Enter the name for the driver or use the default name 7. Click “OK” 8. Enter the IP address of ANC-100e in the “Server’s IP Address or hostname:” field (Default is 192.168.137.2) 9. Click “OK”
  • 3. 3 ANC-100e Ethernet to DH+ Adapter 10.Verify that the Driver is “Running” 11.Click on “Close” button 12.Open “RSWho” window 13.Click the checkbox to activate “Autobrowse” option 14.Double click on the driver element (In our example is TCP-1) to start browsing the ANC-100e. During browsing, you will notice that more elements appear in a branch fashion 15.Keep browsing until you reach “CH A, Data Highway plus” All the devices connected to the same DH+ network as the ANC-100e will appear here
  • 4. 4 ANC-100e Ethernet to DH+ Adapter Appendix ANC-100e DH+ connection There are 2 ways to connect to the DH+ network. - Connect to Processor’s 3-pin connector: Daisy chain a cable from the last DH+ node to the connector of ANC-100e. Polarity of blue and clear cables is irrelevant, as it is auto-detected by ANC-100e - Connect to DH+ Programming Terminal on processor by using the ANC-100e Mini-Din Programming Cable Connect the DH+ cable to ANC-100e and then connect to your Ethernet network or a free Ethernet port on your computer. When the unit turns on, the Ethernet LED blinks several times. Note: if AUTO Baud rate and AUTO DH+ Node options are active in ANC-100e, the device will automatically configure the correct DH+ network speed and find a free DH+ node number to use as its own address. So you don’t need any configuration to start programming DH+ processor. The ANC-100e DH+ LED blinks every 3 seconds if it is associated with the DH+ network and nothing is being transmitted on the DH+ link. When DH+ data exchange takes place, the LED will indicate this by blinking rapidly upon transmitting/receiving a valid DH+ packet. DH+ LED will remain off if the DH+ network is not connected or there are no devices on the connected network. About RSWho window and AutoBrowse option RSLinx “Autobrowse” option is good to initially discover all active nodes on a particular DH+ network quickly and easily, however, because of the extra traffic this feature generates, it is recommended to have the “Autobrowse” checkbox unchecked in the production environment. For more information about settings and other options, please refer to ANC-100e User Manual.