1. Sincerely Prepared by: Engr. Roland J. Macana
Xavier University –Agricultural Engineering Department
AGRICULTURAL ENGINEERING
BOARD EXAM 2014 REVIEW
2. Sincerely Prepared by: Engr. Roland J. Macana
Xavier University –Agricultural Engineering Department
SUBJECTTHREE (3)
15. Burning Efficiency of Rice Hull Furnace is
between 90-100 %
Thermal Efficiency of Rice Hull Furnace is
between 40 – 70 %
Thermal Efficiency of Open Fire Stove is
between 3-11%
Rice hull Gassifier Efficiency is 50-70%
BurningTemperature of Most AgriculturalWaste
is 300-400°C
Thermal Efficiency of Internal Combustion
Engine is 20-30 %
16. Electric Motor 50-90%
Gasoline Engine 25-30%
Diesel Engine 30-36%
The power output of diesel engine when
powered by gas producer at an arbitrary
speed will reduced by 10-20%
The percentage amount of diesel fuel can be
replaced by gas producer is 50-70%
17. Sincerely Prepared by: Engr. Roland J. Macana
Xavier University –Agricultural Engineering Department
SUBJECTTWO (2)
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49. Sincerely Prepared by: Engr. Roland J. Macana
Xavier University –Agricultural Engineering Department
SUBJECT ONE (1)
50. Breeding, Gestation, Farrowing 150 lux
Nurseries 100 lux
Growing and Finishing 50 lux
InspectionAreas 200 lux
Holding Area/Wash Area 100 lux
General Lighting 200 lux
Milking Operation’s Area 500 lux
Stunning Area 220 lux
Dressing Area 540 lux
51. Gut Room/Tripery 220 lux
Cutting and Boning Area 540 lux
Storage 110 lux
Personnel Area 110 lux
WorkingTable 500 lux
Outside the Laboratory 100 lux
Growth Room 100-1000lux
Green House Artificial lighting 200 lux
Refrigerated Storage Room 50 lux
Bench 500 lux
Machine Shed 50 lux
52. Banana 10-13 °C
Beans 0-10 °C
Cabbage 0 °C
Carrot 0 °C
Chinese Brocoli 0 °C
Coconut 0-1.5 °C
Corn Sweet 0 °C
Lettuce 0 °C
Mango 13 °C
Mushroom 0 °C
Onion 0-1.1 °C
Pechay 0 °C
Pineapple 7-13 °C
Squash 5-10 °C
53. Any wall space greater than 0.6 m shall have an
outlet
Provide one 20 Ampere for 46 square meter floor
area.
Provide one 15 Ampere for 35 square meter floor
area.
For 15 Ampere, 8-10 outlets
For 20 Ampere, 10-12 outlets
32 watts per square meter
Electric Current fatal to human body
0.05-0.20 amp
54. Common Sizes of Service Entrance
60,100,150,200 Ampere
AWG #
1. AWG # 14 2 square mm
2. AWG # 12 3.5 square mm
3. AWG # 10 5.5 square mm
4. AWG # 8 8.8 square mm
Human Resistance
1. Dry 500, 000 Ohms
2. Wet 300 Ohms
58. PERT-CPM = Project Evaluation Review
Technique – Critical Path Method
CPES = Contractors Performance Evaluation
System
A system of grading the performance of a
contractor in a specific kind of project using a
set of criteria
RA9184 =The Government Procurement
Reform Act
59. HACCP= Hazard Analysis Critical Control Point
a systematic preventive approach to food
safety and pharmaceutical safety that addresses
physical, chemical and biological hazards as a
means of prevention rather than finished product
inspection.
GMP= Good Manufacturing Practice
regime a quality approach to manufacturing
SSOP = Sanitation Standard Operating
Procedures
60. Buck
Sow
Time of concentration
Freeboard = 0.5 m (NIA)
Loading limit (definition)
Effluent Quota
Pollutant Quota
Sand size ( 0.02-2 mm)
Others : please refer to UPLB Reviewer
61. Iskumbro = Earth fill
Hardinera = Open Stringer
Moisture meter
Volumetric Efficiency (LOKS) 80%
Vertical Bin
Primary Method in Moisture Content
Goat House lux Requirement ( 200 lux)