3. signsurveysnorth
TOYOTA - LEEDS SS2274
1995mm
5250mm
89.7-89.9
89.3-89.6
17785mm
PROPOSED DEMISE LINE
START OF BLANK PANELS
TOYOTA
TOYOTA
HYUNDAI
180mm
NOTE - ALL DIMENSONS ARE FACE SIZES OF EXISTING CLADDING
REQUIRES BESPOKE 650mm HIGH BLANK GREEN PANELS TO MATCH
PROPOSED HYUNDAI SIGN HEIGHT
*PM TO CONFIRM WITH HYUNDAI THAT THEY WILL BE
ALIGNING THE BOTTOM OF THE PANELS TO THE SAME POINT
89.5-89.6
89.5
134.1-134.6
10110mm
133.6-133.9
A
B
B
A
m
m6762
m
m5283
m
m5562
8220mm
2965mm
SECTION THROUGH EXISTING FASCIA A-A PROPOSED FASCIA A-A PROPOSED FASCIA B-B
2000mm
SECTION THROUGH EXISTING FASCIA B-B
B
B
B
B
605mm
650mm
new blank panels
629mm
27mm
CANOPY
OBSTRUCTS
BELOW
NOTE - PANEL WITH DOWNSTAND ONLY REQUIRED TO
SECTION WITH CANOPY BELOW OVERALL LENGTH3825mm
downstand required
to install new panels
top of panels to align through
with rest of fascia - panel height to
be reduced to fit area above canopy
& also take into account downstand
20mm
50mm
4. signsurveysnorth
CITROEN - PRESTON SS1129
252mm
EXISTING TOTEM BASE DETAIL
EXISTING COMMERCIAL SIGN BASE DETAIL
NOTE - THE BASE AND STUDWORK HAS BEEN INSTALLED FOR THE COMMERCIAL VEHICLES
SIGN HOWEVER ONE OF THE STUDS APPEARS TO BE DAMAGED AND SET AT AN ANGLE
792mm 252mm
200mm
mm691
mm037
mm791
mm791
mm091
202mm 2689mm 190mm
200mm
600mm600mm 2300mm
STUD DAMAGED
SET AT ANGLE
15mm dia
2687mm
22mm dia 22mm dia
252mm 792mm
1800mm
252mm
mm052
mm052
mm052
mm009
5. signsurveysnorth
TESCO - LIVERPOOL SS1575
SECTION THROUGH PROFILE A - A
*existing sign face dimensions
*canopy drops down in front of the
sign obscuring some of the top section
*canopy drops down in front of the
sign obscuring some of the top section
SECTION THROUGH PROFILE B - B
Note - fit new sign panels
over existing backtray
roller shutter
*sign fitted at top by
hooking over rails
*sign fitted at top by
hooking over rails
1210mm
1070mm
1070mm
80mm 22mm
30mm
975mm
156mm
220mm
80mm
60mm
22mm
30mm
A
A
B
B
2980mm 3597mm
*11mm short
2605mm 3588mm 2980mm 3875mm
12mm
short
12mm
short
975mm 570mm
200mm
840mm
145mm
cladding panels
1160
360
1130
715
800mm x 400mm standard internally
illuminated projecting sign currently
reads ‘24 hr cash’ (in fair condition)
3020mm
existing 320mm externally applied vinyls existing 320mm external vinyls
2960mm 2960mm
1175
*face fixed camera
524mm
790mm
524mm
mm0002
6. signsurveysnorth
BARBURRITO - LEEDS SS1198
Folded tray panels with
pushed though acrylic lettering
Branded seating areaMenu display unit
Externally applied
contravision graphic
Double sided projecting sign
Looks to be clear acrylic face panels with vinyl
backed up with white opal & black outer edges
Folded tray panels with
pushed though acrylic lettering
(recessed over doorway)
Full backtray to rear
Deep acrylic box with bespoke
lighting and poster frame
7. signsurveysnorth
SHELL PFS - BLACKPOOL SS1284
PUMP 9/10
DIESEL ONLY
1
2
3
4
5
6
7
8 8
9
10
COLLINGWOODAVENUE
CAUNCE STREET
ACCESS ISSUE
CANOPY CLOSE
TO SITE BOUNDARY
ACCESS ISSUE
CANOPY PROJECTS
ABOVE SHOP ROOF
CAR WASH
JET WASH
CANOPY
SHOP
11
8. signsurveysnorth
KFC - GLASGOW SS1686
FLEXFACE BOX
15740mm x 785mm
ALL BOXES HAVE BLACK CLIP FIXINGS
FLEXFACEBOX
8460mmx785mm
FLEXFACEBOX
5914mmx785mm
FLEXFACE BOX
6770mm x 785mm
NOTE - ACCESS ISSUE TO THIS ELEVATION DUE TO HEAVY SLOPING GROUND & SHRUBBERY
SMALL CHERRY PICKER REQUIRED TO WORK FROM PAVEMENT TO ACCESS REAR OF POST
SIGN & ALSO ELEVATION ‘B’
FLEXFACEBOX
6295mmx785mm
FLEXFACEBOX
2505mmx1755mm
FLEXFACE BOX
2505mm x 1755mm
FLEXFACE BOX
5737mm x 780mm
NOTE - SEPARATE BOXES WITH MITRED JOINT
& VELCRO FIXED CORNER TRIMS (MOSTLY MISSING)
SEE CLOSE UP PHOTOS
NOTE - ELEVATION G & D END OF
BOX SITS ON TOP OF CAPPING
UNCLEAR HOW FLAPS WILL OPEN?
A
B
C
D
E
F
G
H
A B C DE FG H
3400mm 3660mm
2600mm
1100mm
*HEAVY SLOPE & SHRUBBERY
SEE SITE PHOTOS
9. signsurveysnorth
TESCO - MANCHESTER SS1542
DENOTES TRAFFIC DIRECTION
DENOTES PHOTO DIRECTION
POST MOUNTED
DIRECTIONAL SIGN
2950mm x 990mm
PHOTOS 11-18
D/S POST MOUNTED
DIRECTIONAL SIGN
1250mm x 1250mm - 60 Rad
PHOTOS 34-39
Photos 81-86 (exit route)
D/S POST MOUNTED
DIRECTIONAL SIGN
1250mm x 1250mm - 60 Rad
PHOTOS 21-31
D/S POST MOUNTED
DIRECTIONAL SIGN
1250mm x 1250mm - 60 Rad
(REPLICATES 66/67)
D/S POST MOUNTED
DIRECTIONAL SIGN
1250mm x 1250mm - 60 Rad
PHOTOS 66-67
D/S POST MOUNTED
DIRECTIONAL SIGN
1250mm x 1250mm - 60 Rad
PHOTOS 70-76
OPTION TO ADD C&C FOR EXIT ROUTE? OPTION TO ADD C&C FOR EXIT ROUTE?
GANTRY 1
GANTRY 1
POSITION
315mm
1855mm
1800mm
1390mm
15
20
24
33 38 51
53
57
59
55
62
64
66
7174
79
84
86
NOTE SIGN OBSCURRED BY TREELINE
SUGGEST NEW POSITION ON LEFT OF ROAD
D/S POST MOUNTED
DIRECTIONAL SIGN
1250mm x 1250mm - 60 Rad
PHOTOS 40-49
10. signsurveysnorth
MAZDA - LEICESTER SS1559
SECTION THROUGH FASCIA
1905mm
50mm
195mm
2585mm
3272mm 3273mm 2388mm 1800mm 2390mm 3315mm
1675mm
NOTE - ANGLE CAN BE WORKED OUT FROM WIDTHS & HEIGHTS OF GLAZING PROVIDED
FRONT ELEVATION NOTE - THERE IS NO SECONDARY SUPPORT STEELWORK INSIDE THE FACE CAPPING
THE EXISTING STRUCTURE WILL NOT SUPPORT A SUSPENDED SIGN SO THIS MAY REQUIRE ADDITIONAL WORKS
BY OTHERS - PM TO CONFIRM OPTIONS
1440mm 1270mm
1142mm 970mm
50mm 50mm 50mm 50mm 50mm 50mm 50mm
195mm
175mm
NOTE - STEELWORK PREVENTS ANY CLEAR
ACCESS TO THE REAR OF THE CLADDING
210mm
20mm
50mm
128mm
145mm
220mm 137mm
140mm175mm
170mm
11. signsurveysnorth
FORD CAT SCAN SURVEY - CASTLETON SS1360
NOTE - DOORS OPEN INWARDS & OUTWARDS
HOWEVER THE SLOPING GROUND MEANS THAT
IT WOULD NOT SIT UNDER THE FEATURE CROSSBAR
SUGGEST FOLDED ANGLE ‘STOPPER’ AS ABOVE AT
POLAR FORD STOCKPORT SO THE DOOR WILL ONLY
OPEN INWARDS
*ALSO TEXT TO WINDOW ‘PUSH/PULL’
NOTE - NOTE SUITABLE FOR SIZE 2 UNLESS DOOR ISSUE IS ADDRESSED
PLAN VIEW
*DENOTES LINE, STRENGTH & DEPTH OF CAT SCAN READINGS
WHERE APPLICABLE
001 (READINGS AT 33 KHz
with generator on low setting)
022 150 DEPTH 0.75
*ASG PM TO ANALYSE CAT SCAN READINGS & ASSESS
SUITABILITY FOR PROPOSED GROUNDWORKS
2210mm
35mm 30mm45mm 45mm
475mm
BLOCK
PAVING
TARMAC
1420mm 1420mm
ALIGN
TEXT PANEL LEFT
1830mm
SUGGEST STOPPER SO
DOORS ONLY OPEN INWARDS
SUGGEST STOPPER SO
DOORS ONLY OPEN INWARDS
2150mm
105mm
152mm
1210mm
015 050
033
033
028016
014 016
019
020
DEPTH <.3
DEPTH <.3
12. signsurveysnorth
SAFESTORE AUDIT & MAINTENANCE - PRESTON SS1300
FRONT ELEVATION - DIBOND PANELS x2
- RUSTED FIXINGS
- VANDALISM TO ONE SIDE PAINTED OUT - SEE PHOTOS
- CORROSION TO POSTS - SEE PHOTOS
RECEPTION - BOX SIGN WITH OPAL PANELS/VINYL
- REQUIRES CLEANING
- MAY REQUIRE RE-TUBING
- PAINT BUBBLING TO TRIM EDGES - SEE PHOTOS
FRONT ELEVATION - MAIN SIGNAGE ABOVE OFFICES
- FLEX FACE SKIN IN VERY POOR REPAIR - FADED
- SUGGEST REPLACEMENT SKIN
- MAY REQUIRE RE-TUBING
3375mm TO FLAT ROOF LEVEL
RIGHT RETURN ELEVATION LEFT END - 2470mm TO U/S
- FLEX FACE SKIN IN VERY POOR REPAIR - FADED
- SUGGEST REPLACEMENT SKIN
- MAY REQUIRE RE-TUBING
- PAINT BUBBLING/PEELING TO BOX EDGES - SEE PHOTOS
FRONT ELEVATION STEP RETURN
- FLEX FACE SKIN IN VERY POOR REPAIR - FADED
- SUGGEST REPLACEMENT SKIN
- MAY REQUIRE RE-TUBING
RIGHT RETURN ELEVATION - RIGHT END
- FLEX FACE SKINS (3OFF) IN VERY POOR REPAIR - FADED
- SUGGEST REPLACEMENT SKIN
- MAY REQUIRE RE-TUBING
REAR ELEVATION - LEFT END
- FLEX FACE BOX SIGN
(THIS IS NOT IN AS POOR CONDITION AS THE OTHERS)
- REQUIRES CLEANING
- MAY REQUIRE RE-TUBING
REAR ELEVATION - NON ILLUMIANTED TRAY PANELS
- LOOKS OK MAY REQUIRE MINOR CLEANING
- 5200mm TO UNDERSIDE
A
B
D
E
F
GH
C
A B
C D
E F G H
14. signsurveysnorth
jamie livesey
07403 414 609
jamie@signsurveysnorth.co.uk
www.signsurveysnorth.co.uk
www.thecreativeartcompany.co.uk
sign surveys north
the creative art company studio
fourteen roseberry road
ashton in makerfield
wigan
greater manchester
wn4 9tb