Data center-power point-charisv.1
1. Buildings & General Specification
by Charis Charalambous / Ucy Noc Team
Data Centers
2. Data Center is the facility that was
designed to host equipment that refers
to telecommunication systems,
computational systems and storage
systems. All the active equipment
installed in a data center is usually
equipped with dual power supplies and
Ethernet connections. Also dual
internet service provider connections
and dual power feeds, UPS and
Generators apply to data centers to
ensure redundancy and business
continuity.
Data Center Definition
3. • Data Center Design philosophy
• Rack and Computational equipment loading
• Numerous environmental sensors and monitoring services
• Data Center Design Criteria
• Architectural Design -> (space planning , floor, light,
security etc),Redundant access to ,No exterior windows (
increase heat and security risk),Delivery of Large
equipment,Provide authorized access & monitored
• Structure Wiring-> Fiber / Copper/ twinxial Cables
• Electrical-> UPS /Generator / Dual feeds on the Grid/
• Cooling / Mechanical-> HVAC systems / dual
connections
• DCIM System-> environmental Sensors , smart PDU’s ,
fire suppression
Contents
4. Designing a Data Center
Site Selection
Power
distribution
HVAC and other
environmental
controls
Implementing
a raise floor
Network
Cabling
Infrastructure
5. Data Center Structure
Cabling
FIBER Multimode
and Single mode –
type of fiber
OM3/OM4, OS2
100-ohm twisted
pair cable category
5e ,6, 6a,7 FTP / 10
GbE cat6 ->37 -
55mtr / cat6a and
cat7 ->100 mtrs
SFP+ DAC twinxial
cable can reach
10Gb for max
distance 10 mtr
7. Cooling / Mechanical
Managing the airflow around the
server cabinets is critical to
prevent hardware from
overheating - solutions to
manage this is by using blanking
panels foam tape, sealing
grommets and high-flow air tiles.
Sealing the openings in the
raised floor and the bottom and
top cover of racks with sealing
grommets prevents cool supply
air from escaping where is not
needed.
Determine cooling delivery
methodology
Room , rack , row
Blank panels , sealing
grommets
Cold air containment
Dual
power and
cooling
paths
Avoid blocking
cooling ducts
and return air
paths
Determine the
CFM
requirements
per RLU / Rack
Proper internal
configuration
of racks
(airflow)
Determine
critical heat
load
8. Fire Detection and Suppression
Detection -> both heat
and smoke detection
Airflow patterns
determines location of
detection units
Suppression ->Folllow
NFPA 75 standard
Use of chemical
systems or clean agent
(FM200, inergen etc)
Install springer systems
and connect with
DCIM to interfere with
the crack units in case
of fire.
9. DCIM
• servers• racks
• cooling• power
DCIM
Monitors
and manages
Critical
assets
Multi-site
management