In this newsflash find out about our Disease State Plasma range and be one of the first to learn about our exciting new product launch of Clinical Specimen Panels coming soon to the BBI Solutions product portfolio.
Top 20 Famous Indian Female Pornstars Name List 2024
April 2015 - Disease State Plasma Newsflash - BBI Solutions
1. Technical DSP Newsflash
April 2015
Coming in 2015
Clinical Specimen Panels
Disease State Plasma
Synthetic Rubella Serum
Allergy Plasma
Inventory correct at time of publication
InnovationResultsPartnershipQuality
2. Save time and optimise your success
rate by selecting from our highly
characterised disease state plasma units.
Have confidence in supply sustainability
and traceability by choosing a trusted
partner with global collections directly from
hospitals and blood banks. Stored at a
HTA licenced facility.
Wide range – we offer rare and early
stage disease state materials.
Our disease state plasma, samples and
remnant materials are collected with
ethics approval and donor consent
when relevant.
Why choose BBI?
Quick Links
Coming in 2015
Disease State Plasma
Synthetic Rubella IgM Serum
IgE Raised (Allergy) Plasma
Capabilities
How to Order
3. Coming in 2015
Clinical Specimen Panels
Designed to help you:
Evaluate sensitivity and specificity
of new test methods and equipment
Perform Internal QC for proof of
concepts
These panels will include patient
samples containing the following:
Hepatitis virus
HIV
Syphilis
Pregnancy samples or serum
Donor consent
Ethics approval / IRB
Native, undiluted material
Contains no preservatives
Return home >
4. “Our Synthetic Rubella
IgM Serum demonstrates
excellent batch to
batch consistency, not
seen in a native serum”
Synthetic Rubella IgM Serum
What is Synthetic Rubella IgM Serum?
A product formulated with real human Rubella IgM
and designed to mimic native disease state serum.
Why do we need it?
Native disease state plasma is used in the
manufacture of controls and calibrators.
However, since most people are vaccinated for
Rubella at a young age it is very difficult to source
a native plasma.
Our synthetic Rubella IgM serum is a great
alternative to native disease state plasma for the
consistent manufacture of controls and calibrators.
Return home >
5. Our results demonstrate that the 3 Synthetic Rubella IgM Serum batches are
comparable with the native positive control sample; there is also excellent
batch to batch consistency across a dynamic range.
Synthetic Rubella IgM Serum – what we offer
0
4
8
12
16
20
0 5 10
s/coIndexValue
Dilution Factor
Abbott Architect
Batch 1
Batch 2
Batch 3
Positive Control
Negative control
0
4
8
12
16
20
0 5 10
s/coIndexValue
Dilution Factor
Siemens Immulite
Batch 1
Batch 2
Batch 3
Positive Control
Negative control
0
4
8
12
16
20
0 5 10
s/coIndexValue
Dilution Factor
Roche COBAS
Batch 1
Batch 2
Batch 3
Positive Control
Negative control
0
4
8
12
16
20
0 5 10
s/coIndexValue
Dilution Factor
BioMerieux VIDAS
Batch 1
Batch 2
Batch 3
Positive Control
Negative control
Return home >
6. How is IgE raised plasma produced in the body?
IgE antibodies are a distinct class of antibody, specific for particular allergens.
They bind to the surface of mast cells, which become ‘IgE-sensitised’.
In this way, the cells can then identify these particular allergens the next time
they come in contact with the body.
Mast cells are present in tissues that are in contact with the external
environment, including the skin, nose, eyes, mouth, throat, stomach and gut.
The next time that the same allergen is encountered the mast cells identify it as
an intruder and produce histamine and other chemicals.
It is the release of these chemicals from mast cells and
their effects on the body that result in allergic symptoms.
IgE Raised (Allergy) Plasma
Return home >
7. The plasma collected by BBI Solutions is collected mainly
from a single donor with an exceptionally high level of Total
IgE.
Total IgE values for units of this material are typically
>15,000 KU/L with some seasonal variation.
Titre levels for IgE are measured using either the Beckman
Access or Roche E Modular E170 analysers.
Current inventory available is >10 L.*
We are also able to source material for specific IgE, with
donors tested by Phadia ImmunoCap.
IgE Raised (Allergy) Plasma – what we offer
*Inventory correct at time of publication
Return home >
8. Infectious Disease Autoimmune Cardiac
Chlamydia IgG / IgM Anti-GBM Cholesterol
CMV IgG / IgM / Negative - CMV Anti-RNP / Anti-SSA HDL
EBV IgG / IgM ANCA (Anti-MPO / Anti-PR3) Hypertension
H. Pylori Celiac Disease LDL
HAV IgG / IgM Crohn’s Disease Triglyceride
HCV IgG Gliadin Antibodies IgA / IgG
HBsAg HAMA Organ Failure / Impairment
HBc IgM / Total Ab Rheumatoid Factor Renal Failure
HBeAg / HBeAb SLE / dsDNA Ab / Histones Ab - NEW Kidney Transplant
HIV 1 Tissue Transglutaminase Abs Liver Transplant
HIV 2 Anti-CCP Negative
HSV I/II IgG / IgM / Negative - NEW Intrinsic Factor Ab Diabetes
HTLV-1 VGKC Ab Glucose
HTLV-2 HbA1c
HEV Autoimmune Thyroid Disease Diagnosis (Type I / II)
Lyme IgG / IgM Anti-Tg
Malaria Anti-TPO Pregnancy
Parvovirus B19 Graves Disease Amniotic Fluid
Rubella IgG / IgM / Negative - NEW Hashimoto’s Disease Pregnancy Serum
Synthetic Rubella IgM – NEW Chronological Bulk Urine
Syphilis IgG / IgM Inflammation / Allergy
Toxoplasma IgG / IgM / Negative - NEW CRP Other Biomaterials
SAA Cord Serum
Biochemistry Specific IgE (Allergy) Urine
Vitamin D Saliva
Drugs of Abuse CSF
CDT
Our Capabilities
Return home >
9. How to Order
Please get in touch to arrange a quote for
any of our products.
If you can’t find what you are looking for, take
a look at some of our customised services:
Custom collections
Pooling service
Custom testing / screening
Custom specifications for products
requiring regular supply for production
info@bbisolutions.com
USA: 1-800-423-8199
Intl: +44 (0) 2920 747 232
Quote on ordering: NFAPR
BBI Solutions
bbi_solutions
BBI Solutions
Return home >