23. Structure & Function Injector
The injector piston (2) is in its normal or
“rest” position. The discharge chamber (3)
is filled with lubricant from the previous
cycle. Under the pressure of incoming
lubricant(6), the slide valve (5) is about to open
the passage (4) leading to the
measuringchamber (1) above the injector
piston (2).
STAGE 1
24. Structure & Function Injector
When the slide valve (5) uncovers the passage
(4), lubricant (6) is admitted to the
measuring chamber (1) above the injector
piston (2) which forces lubricant from the
discharge chamber (3) through the outlet
port (7) to the bearing.
STAGE 2
25. Structure & Function Injector
As the injector piston (2) completes its
stroke, it pushes the slide valve (5) past the
passage (4), cutting off further admission of
lubricant (6) to the passage (4) and measuring
chamber (1). The injector piston (2)
and slide valve (5) remain in this position
until lubricant pressure in the supply line (6)
is vented (relieved at the pump).
STAGE 3
26. Structure & Function Injector
After venting, the injector spring expands,
causing the slide valve (5) to move, so that
the passage (4) and discharge chamber (3)
are connected by a valve port (8). Further
expansion of the spring causes the piston
to move upward, forcing the lubricant in the
measuring chamber (1) through the passage
(4) and valve port (8) to refill the
discharge chamber (3).
STAGE 4
30. FIRE
- +
Battery Relay
Std
Rotary Lamp
Optional Lamp
Optional Lamp Switch
(LS)
SOL
B C R S
Kabel Std
‘C’
Kabel Std
‘ACC’
Kabel Std
‘B’ Kabel Std
‘Br’
Starting Switch CAT
(SS)
Emergency Stop Inside
(ES 1)
AUTOLUBE
CONTROLLER
IGN
Sol
(+)
(-)
Battery Relay
Relay Engine Shut Down
(R 2)
Relay St Switch
CAT (R1)
Battery
Emergency Stop Outside
(ES 2)
Push Button Grease
(GS)
Converter
24V to 12V
12V
(-)
24V
B
B B
B
B
B
B
BL
BL
R
R
BL
R
R
R
R
R
R
R
R
BL
R
R
R
R
R
R
R
R
R
R
R
TS 1
OP 1
OP 2
OP 3
OP 4
AL
Y
Y Y
Y
R
FE
B
B
B
Y
BL
BL
Y
BL
Y
R
R
R
R R
R
R
R Y
Y
BL
BL
R
BL R
BL
R
W
W
Y
Y
W
W
R
BL
BL
W
W
R
R
Y
BL
BL
W
W W
W
R
R
BL
BL
R
R
W
W
Y
Y
Y
Y
BL
BL R R
R
W
W
R
R
R R
6
5 1 3
2 4
1 2 3 6
5
PT UNITED TRACTORS, Tbk
Sangatta Site
Drawing :
Unit :
Code :
Design :
Optional Electric
PC 750-6
B 602
TC Dept.