Factory security and safety convex mirrors in Kenya
AlfaSaftyEnclosure_B1r5.1
1. Simultaneous operation of SE built in a row.Flexible construction allows SE to be setup almost anywhere.SE for crane repair
The Safety Enclosure (SE) can be deployed by a 2
man team quickly and efficiently in almost any area;
Scaffolding is used to prepare and define the work
area;
Panels are of standard size 1m x 1m or 2m x 1m;
Panels are constructed out of silicone coated fiber
glass fabric. They are light weight and flame
retardant;
Industrial type fasteners and integrated Velcro seal-
ing strips are attached to each panel;
High powered low noise blowers provide the posi-
tive pressure;
Anti Static spiral hoses are used for routing the air
from blower to SE and for exhaust;
Panel box, Internal lights and external blowers are
rated explosion proof;
Panel Box will auto-shutdown when specific condi-
tions are met;
Audio and Visual alarms will activate during shut-
down;
Fast & Efficient Deployment
IEC 60076.17 compliant
ABS (American Bureau of Shipping) certified
Gas Detection Certification
Gas analyzers are placed before the air intake blowers. This
is to prevent explosive or poisonous gasses from entering
the safe work zone within the Safety Enclosure (SE).
Workers entering the SE should also carry a personal gas
detector. If any gas is detected, the shutdown protocols can
be activated manually by pressing the emergency shutdown
button.
Personal gas detector Emergency STOP
Hot Work is one of the most dangerous
operations where oil and gas general con-
tractors can perform and continues to be a
principal source of fires and explosions
accountable for many of the industry's
most severe losses.
2. For Zones 1 & II Hazardous areas
For more information contact:
Phone : +62 21 6470 0022
Fax : +62 21 6470 0033
E-mail : andreas@alfametalindo.com
SUMMARY OF ADVANTAGES
Eliminates the need for unscheduled shut-downs;
Built for use in Zone I & II Hazardous areas.
Positive pressure acts as barrier to prevent ingress of
Hydrocarbons;
ABS Certified ;
IEC 60079.17 compliant;
Explosion proof rated parts;
Isolates the welding area;
Confines grinding sparks and cut or welding splatter;
Provides a positive pressure barrier between hot works
and hazardous flammable area;
Contains Heat Source;
Protects assets from wear and damage;
Quick and easily deployed by 2 technicians;
Variable configurations available;
Double aluminum door air-lock system for convenient
entry and minimal loss of pressure;
Provides Audio & Visual warning upon danger detection
and auto shutdown;
Durable and heat resistant silicone coated fiber glass based
panels; and
Ropes are Anti Static.
Use in Oil and Gas Refineries or Rigs
PT ALFA METALINDO
INDONESIA
Safety
Enclosure (SE)
for
Hot Works
Komp Rukan Mahkota Ancol Blok C No. 53-55
Jl. R.E. Martadinata, Jakarta 14420 Indonesia
Telp : +62 (21) 6470 0022 (Hunting)
Fax : +62 (21) 6470 0033
HP : +62 812 1959 6076
Email : andreas@alfametalindo.com
Website : WWW.ALFAMETALINDO.COM
PT. ALFA METALINDO INDONESIA
Specialist for your Cutting & Welding needs
Andreas Subagio
Business Development Manager
AUTOMATIC SHUTDOWN WHEN :
AUTO SHUTDOWN SYSTEM UTILIZING THE PLC CON-
TROL FOR OVERALL OPERATION, WITH LCD DISPLAY
IF THE PRESET PARAMETER TRIGGERS
1. 5% LEL OF FLAMMABLE GAS (METHANE) REACHED
OR
2. 10 PPM OF TOXIC (H2S) GAS DETECTED
INTERNAL TEMP REACH 42° CELCIUS OR ABOVE
PRESSURE DROPS BELOW 25 PASCAL
EMERGENCY STOP IS MANUALLY ACTIVATED
Two types of alarms available:
- Audio & Visual
SAVE TIME AND MONEY BY GETTING THE JOB
DONE WITHOUT SHUTTING DOWN
PRODUCTION