1. 20137 Milano - Via Ennio, 25
Tel.: +39 02 5410 0818 - Fax +39 02 5410 0764
E-mail: controllogic@controllogic.it - Web: www.controllogic.it CONTROL LOGIC s.r.l.
SYS-A
Small simple system*
It includes:
no. 1 RIV-601P/S
spark detector
no. 1 SAM-870
mounting frame
no. 1 PAN-705
control panel
no. 1 SNA-808L
alarm sounder beacon
no. 1 EVS-811
solenoid valve
no. 1 UGN-820
spray nozzle
SYS-B
Large simple system*
It includes:
no. 2 RV-601P/S
spark detector
no. 2 SAM-870
mounting frame
no. 1 PAN-705
control panel
no. 1 SNA-808L
alarm sounder beacon
no. 1 EVS-811
solenoid valve
no. 2 UGN-820
spray nozzle
SYS-E1
Small complete system*
It includes:
no. 2 RIV-601P/S
spark detector
no. 2 SAM-870
mounting frame
no. 1 PAN-705
control panel
no. 1 SNA-808L
alarm sounder beacon
no. 1 EVS-811
solenoid valve
no. 1 PAC-846
water flow switch
no. 1 UGN-820
spray nozzle
SYS-E
Large complete system*
It includes:
no. 4 RV-601P/S
spark detector
no. 4 SAM-870
mounting frame
no. 1 PAN-705
control panel
no. 1 SNA-808L
alarm sounder beacon
no. 1 EVS-811
solenoid valve
no. 1 PAC-846
water flow switch
no. 2 UGN-820
spray nozzle
* Note:
• “A” and “B” systems are “simple” because they only perform the detection and extinguishing operations, but not the
monitoring functions.
• “E1” and “E” systems are “complete” because they include all functions of detection, extinguishing and monitoring
• “Small” systems are suited for ducts with diameter up to half a meter.
• “Large” systems are suited for ducts with diameter up to one meter.
RIV-601P/S
spark detector
designed for dust collection systems
to protect storage silos from the risk of fire
SPARK DETECTOR SYSTEMS
RIV-601P/S
spark detector
• Sparks fly at high speed.
They travel at hundred kilometers per hour along
the ducts of the dust collection system and reach
the silo in less than three seconds.
• THE CONTROL LOGIC SPARK DETECTOR
is faster than the sparks themselves.
It detects them with its highly sensitive infrared sensor,
intercepts and extinguishes them in a flash.
• THE CONTROL LOGIC SPARK DETECTOR
needs no periodic inspection.
• THE CONTROL LOGIC SYSTEM
is designed for “total supervision”.
It verifies that spark has been extinguished, gives
prompt warning of any malfunction and, if needed,
cuts off the duct and stops the fan.
y ear warranty
2. ModelNo.V6EPB
SerialNo.
ClassI,groupsB,C,D
ClassII,groupsE,F,G
Listedforhazardous
locations986G
FLOTECT
DETECTION
EXTINGUISHING
MONITORING
DUCT VALVE
Model No. V6EPB
Serial No.
Class I, groups B, C, D
Class II, groups E, F, G
Listed for hazardous
locations 986G
FLOTECT
SAM-870
Mounting frame
Cover with anti-vibration
rubber cushions.
For an easy mounting of
spark detector RIV-601P/S
over the air duct.
RIV-601P/S
Spark detector
It detects burning
particles flying inside
dust collection ducts.
SAM-870
Mounting frame
Base with built-in optical
window.
EVS-811
Solenoid valve for water
It opens water flow to the
extinguisher spray nozzle.
PAC-846
Water flow switch
It monitors water flow to the
spray nozzle.
It will signal any water leakage
due to solenoid valve
malfunction.
UGN-820
Extinguishing spray
nozzle
It sprays for 3 seconds at
everyspark detected.
SNA-808L
Alarm suonder bea-
con
It sounds and flashes
when spark detectors
go in alarm and if there
is a water leakage.
PAN-705
Control panel
Used in spark detector
systems with RIV-601P/S
detectors.
It provides visual signals of
detectors alarm state and
controls the extinguishing
and/or the emergency stop.
Performs the test sequence.