ce226hw4
- 1. Conductor and Conduit Schedule
AWG or
CABLE
Conductor Run
#14
Φ1 3 3 3
Φ2 9 3 6 6 6
Φ3 6 3 3 3 3 3 3 3 3
Φ4 6 3 3 3 3
Φ5 3 3 3 3 3
Φ6 9 6 6 3 3 3 3
Φ7 3 3 3
Φ8 3 3 3 3 3 3
Φ2P 4 2 2 2 2
Φ4P 4 2 2 2 2
Φ6P 4 2 2 2 2 2 2
Φ8P 2 2 2 2 2 2
Φ2PPB 1 1 1
Φ4PPB 1 1 1
Φ6PPB 2 1 1 1 1 1 1 1 1
Φ8PPB 1 1 1 1 1
PPB Common 2 1 1 1 1 1 1 1 1
P.E.C. 3
Spares 6 3 3 3 3 3 3 3
Total # 14 69 30 25 13 13 22 30 34 39
# 10
Internally Illuminated
Street Name Sign
2 2 2 2 2 2 2 2
Luminaires 2 2 2 2 2 2 2 2
Signal Common 2 1 1 1 1 1 1 1 1
Total # 10 2 5 5 5 5 5 5 5 5
#6 Signal Service 2
Detector
-Lead-In
Cable
Φ1 Detectors 1 1 1 1 1
Φ2 Detectors 4 4
Φ3 Detectors 1 1 1
Φ4 Detectors 2 1 1 1 1 1 1 1 1
Φ5 Detectors 1 1
Φ6 Detectors 4 4 4 4 4
Φ7 Detectors 1 1 1 1 1
Φ8 Detectors 2 2 2
Total DLC 15 6 1 1 2 7 7 10 10
EV Cable “A” 1 1 1
EV Cable “B” 1 1 1 1 1
EV Cable “C” 1 1 1
EV Cable “D” 1
Video Cable 1 1 1 1 1 1 1 1
Video Power Cable 1 1 1 1 1 1 1 1
Signal Interconnect Cable
(SIC)
1 1 1 1 1 1 1 1
Conduit Size 2-3” 3” 2.5” 2” 2” 3” 3” 3” 3.5”
Percentage Filled 19% 19% 19% 20% 22% 18% 20% 24% 19%
Pole and Equipment Schedule
Standard Vehicle Signal Mast Ped. Signal Mtg. PPB HPS. Lum. Special Requirements
Type Signal Mast Arm Luminaire
Mast Arm
Wind Velocity
mph
Feet Feet Mast Pole Φ Arrow
A 24-3-100 35 12 MAT
MAS
SV-1-T SP-1-T 6 200W Internally Illuminated Street Name Sign "Major Street"
B 1A TV-2-T SP-1-T 8
C 29-5-100 50 15 MAT
MAS
SV-1-T SP-1-T 8 200W Internally Illuminated Street Name Sign "Minor Avenue"
D 1A TV-2-T SP-1-T 2
E 24-3-100 35 12 MAT
MAS
SV-1-T SP-1-T 2 200W Internally Illuminated Street Name Sign "Major Street"
F 1A TV-2-T SP-1-T 4
G 29-5-100 50 15 MAT
MAS
SV-1-T SP-1-T 4 200W Internally Illuminated Street Name Sign "Minor Avenue"
H 1A TV-2-T SP-1-T 6
Conductor and Conduit and Pole and
Equipment Schedule
April 23, 2014