2. CONSTRUCTION SYSTEMS INDIA
Reo502™
Specification Chemical Anchoring
2
Company Profile
ITW Construction Systems is a Fortune 150 diversified manufacturing company
that was founded on innovation and expanded on the strength of its customer
commitment. For over 100 years, ITW employees have kept an entrepreneurial
spirit alive that is firmly focused on its customers. ITW Construction Systems,
India has its Head Office in Hyderabad with sales offices in Delhi and Vadodra and
warehouse facilities in Chennai and Hyderabad. Our team of professionals is well
supported by ITW technical experts worldwide.
Masters of concrete technology
ITW expertise in concrete technology includes systems for chemical and
mechanical anchoring, drilling, diamond coring, construction chemicals, as
well as direct fixing into concrete and steel. Our areas of speciality include:
Cracked and non-cracked concrete anchoring systems tested to and compliant
with International standards, front to back of project enginnering design and
specification services.
Designed and engineered to work
ITW minimise design risk and maximize project performance by developing and
manufacturing a significant portion of its anchoring systems. Our dedicated
approach to product development and manufacturing has resulted in production
efficiencies, greater flexibility, the ability to quickly adapt products to project
needs and to deliver to the customer in full on time
Anchoring design services
ITW provides assistance for qualified design professionals to choose a suitable
anchoring solution which meets a project specific set of design inputs such as:
Design tools for anchor layouts and calculating performance in grouped
anchor configurations, tailored outcomes to suit project specific anchoring and
perfomance criteria. ITW is a quality endorsed company.
Quality construction brands
Self drilling screws and fasteners
Performance Engineered anchoring, drilling
and fixing systems
International approved anchoring, drilling
and fixing systems
Lifting, reinforcing, fastening and propping solutions
for precast concrete and on site tilt up construction.
Industrial concrete flooring and pavement construction
systems specialist
Expansion joint solutions for civil and architectural
construction projects
4. CONSTRUCTION SYSTEMS INDIA4
Reo502™
Specification Chemical Anchoring
Features & Benefits
• Extended working time for hot climates and deep embedments.
• Sag resistant formula for horizontal and over head holes
• Bonds to carbide and diamond core drilled holes
• For Grade 500 reinforcing bar
• Excellent electrical insulation properties
• Dry, wet, flooded** and underwater** holes
• Green building and VOC compliant
• Same day loading of anchors
• Low odour
Description
Extra heavy duty anchoring of reinforcing bar and threaded studs into solid
concrete and stone.Two-component, high strength non shrink bond epoxy
adhesive specially designed for structural connections, such as reinforcing
bar. Suitable for dry, damp, wet and flooded holes. Extended working time for
hot climates. Engineered for structural reinforcing bar connections in slabs,
columns, beams and walls, structural steel columns, raker angles, seating.
Trades & Applications
Concreter Building
Contractor
Civil
Contractor
Steel
Fabricator
Balustrade
Contractor
Formworker Bricklayer Fitter
Post-installing reinforcing bar 4 4 4 4
Starter bars 4 4 4 4 4
Threaded studs 4 4 4 4 4
Related Products
DynaDrill™
Carbide Drill Bits
Diamond Motor
Diamond Core Drill Bits
VOC
Compliant
Dispensing Tool
Wet/Dry Vacuum
Hole Cleaning Brushes
Hole Cleaning Pump
Robust, puncture
proof packaging
Translucent cartridge to
see remaining contents
Typical Properties
Properties Typical Value
Appearance Part A: White Part B: Black
Mixed: Light Grey
Density 1.28 kg /litre @ 20°C
Heat Distortion Temperature Approx 80°C
Hardness > Shore D 80
Compressive Strength (ASTM D695) 105 MPa
Compressive E Modules (ASTM D695) 5 GN/m2
Tensile Strength (ASTM D638) 23.5 N/m2
Tensile Elongation at break (ASTM D638) 5.9%
Tensile Modulus (ASTM D638) 5.5 GN/m2
Flexural Strength (ASTM D790) 45 N/m2
Service Temperature Limits -40°C to 80°C
Chemical Resistance See Technical Data Sheet
Substrates Solid Concrete
Dielectric constant 3.95
Conductivity 8 x 10-11
ohmS/m
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Cracked
Concrete
Fire
Resistant
Seismic Hot dipped
Galvanised
Stainless
Steel
ETA Option 1 (pending)
Cracked Concrete
Fire tested TR020
ETA
European Technical Approval
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Zinc Plated
5. CONSTRUCTION SYSTEMS INDIA5
Reo502™
Specification Chemical Anchoring
Installation in Solid Concrete
1. Drill hole to specified diameter and depth
2. Remove dust and debris by brushing and blowing 3 times each (If hole is wet
or flooded, brush only remove water and slurry with wet/dry vacuum)
3. Screw mixing nozzle onto cartridge and dispense 2-3 trigger pulls of adhesive
to waste until colour is light grey with no streaks
4. Insert tip of nozzle to bottom of hole and dispense adhesive
5. Fill hole to about 2/3 full
6. Insert threaded stud or reinforcing bar with rotating motion to release trapped air
7. Wait until adhesive has fully cured before loading (see Time chart below)
8. Clean up with acetone
Reo 502™
- Indicative Working Loads in 32 MPa Concrete with ChemSet™
Anchor Studs
Thread
Size
Drilled Hole
Ø (mm)
Min Hole
Depth (mm)
Tightening
Torque (Nm)
Min Edge
Distance (mm)
Min Anchor
Spacing (mm)
Max Tensile
Load, Na (kN)
Max Shear
Load, Vas (kN)*
M8 10 80 10 35 50 6.3 4.4
M10 12 90 20 40 60 10.3 7.1
M12 14 110 40 50 75 15.3 10.5
M16 18 125 95 65 100 29.4 19.9
M20 24 150 180 80 120 37.9 29.9
M20 24 170 180 80 120 43.0 29.9
M24 26 160 315 100 145 40.9 43.3
M24 26 210 315 100 145 53.6 43.3
M30 32 270 600 120 180 72.4 90.4+
M36 38 330 1050 145 220 101.5 131.7+
Bold working load values in tension are limited by steel. All other values limited by concrete and adhesive bond
* For shear acting towards a concrete edge please contact a Ramset Engineer for further design assistance
+ M30 and M36 steel shear values are for Grade 8.8 carbon steel. All other values are for Grade 5.8 carbon steel.
**For water saturated or under water holes, reduced tensile load capacity applies.
For load capacity data according to ETA standards consult ETA reports
Reo 502™
- Indicative Working Loads in 32 MPa Concrete with Post installed Reinforcing Bar
Thread
Size
Drilled size
(mm)
Min Hole
Depth (mm)
Min Edge Distance
(mm)
Min Anchor Spacing
(mm)
Max Tensile
Load, Na (kN)
Max Shear Load,
Vas (kN)* Grade 500
N10 14 90 40 60 10.4 9.7
N12 16 110 50 70 15.2 14.0
N16 20 125 65 100 23.1 24.9
N20 25 150 80 120 34.7 38.9
N24 30 160 100 145 44.4 56
N24 30 210 100 145 58.2 56
N32 40 255 130 195 94.3 99.7
N32 40 300 130 195 110.9 99.7
Working load capacity was derived from characteristic
ultimate load capacity by applying the following factors:
Tension: Concrete = 3, Steel = 2.2
Shear: Steel = 2.5
Hole Condition
Hole Condition Suitable
Dry Yes
Damp Yes
Wet Yes
Flooded Yes
Drill Bit Type
Carbide Yes
Diamond Core Yes
Hole Orientation
Vertical Down Yes
Horizontal Yes
Vertical Up (Overhead) Yes
Reo 502™
Anchoring Adhesive
Description Part No Box Quantity
Reo 502™ (600 ml) + 1 Nozzle REO502M600 12
Reo 502™ (400 ml) + 1 Nozzle REO502M400 12
Dispensing Tool (600ml 1:1 ) CD60011 1
Dispensing Tool (400ml 1:1 ) CD40011 1
For installation accessories see page 12-13
Working and Loading Time
Substrate Temperature
(°C)
Gel Time
(min)
Cure Time
(hours)
10 - 15 20 12
15 - 20 15 8
20 - 25 11 7
25 - 30 8 6
30 - 35 6 5
35 - 40 4 4
40 - 45 3 3
Recommended Installation Temperatures
Minimum Maximum
Substrate 10°C 45°C
Adhesive 20°C 45°C
Application test on-site before use is recomended. Consult technical data reports before commencing use.
Refer to Technical Data Sheet and MSDS.
For precautions and further detailed installation instructions
6. CONSTRUCTION SYSTEMS INDIA6
Sructaset 402™
Structural Chemical Anchoring
Features & Benefits
• Extended working time for hot climates
• Sag resistant formula for horizontal and over head holes
• For Grade 500 reinforcing bar
• Rated for sustained loading
• Green building and VOC compliant
• Same day loading of anchors
• Low odour
Description
Structaset 402 is a Vinyl Ester adhesive for heavy duty anchoring
of reinforcing bar and threaded studs into solid concrete. Designed for
structural steel connections, road stitching, seating and hand rails, starter
bars and barriers. Extended working time for hot climates. Suitable for dry,
damp, wet and flooded holes. Vertical, overhead and horizontal anchoring
applications.
Trades & Applications
Concreter Building
Contractor
Civil
Contractor
Steel
Fabricator
Balustrade
Contractor
Formworker Bricklayer Fitter
Post-installing reinforcing bar 4 4 4 4
Starter bars 4 4 4 4 4
Threaded studs 4 4 4 4 4
Related Products
DynaDrill™
Carbide Drill Bits
Impact Driver
Wet/Dry Vacuum
VOC
Compliant
Hole Cleaning Brushes
Hole Cleaning Pump
Dispensing Tool
Robust, puncture
proof packaging
Translucent cartridge to
see remaining contents
Typical Properties
Properties Typical Value
Appearance Part A: White Part B: Black
Mixed: Light Grey
Density 1.67 kg /litre @ 20°C
Heat Distortion Temperature Approx 80°C
Hardness > Shore D 80
Compressive Strength (ASTM D695) 77.8 MPa
Compressive E Modules (ASTM D695) 5 GN/m2
Tensile Strength (ASTM D638) 15.2 MPa
Tensile Elongation at break (ASTM D638) 5.9%
Tensile Modulus (ASTM D638) 5.5 GN/m2
Flexural Strength (ASTM D790) 29 MPa
Service Temperature Limits -40°C to 80°C
Chemical Resistance See Technical Data Sheet
Substrates Solid Concrete
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Cracked
Concrete
Fire
Resistant
Seismic Hot dipped
Galvanised
Stainless
Steel
ETA Option 7
TR029
ETA Option 1 (pending)
Cracked Concrete
Fire tested TR020
ETA
European Technical Approval
ETA
European Technical Approval
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Zinc Plated
7. CONSTRUCTION SYSTEMS INDIA7
Structaset 402™
Structural Chemical Anchoring
Installation in Solid Concrete
1. Drill hole to specified diameter and depth
2. Remove dust and debris by brushing and blowing 3 times each (If hole is wet
or flooded, brush only remove water and slurry with wet/dry vacuum)
3. Screw mixing nozzle onto cartridge and dispense 2-3 trigger pulls of adhesive
to waste until colour is light grey with no streaks
4. Insert tip of nozzle to bottom of hole and dispense adhesive
5. Fill hole to about 2/3 full
6. Insert threaded stud or reinforcing bar with rotating motion to release trapped air
7. Wait until adhesive has fully cured before loading (see Time chart below)
8. Clean up with acetone
Structaset 402™
- Indicative Working Loads in 32 MPa Concrete with ChemSet™
Anchor Studs
Thread
Size
Drilled Hole
Ø (mm)
Min Hole
Depth (mm)
Max Fixture
thickness (mm)
Tightening
Torque (Nm)
Min Edge
Distance (mm)
Min Anchor
Spacing (mm)
Max Tensile
Load, Na (kN)
Max Shear
Load, Vas (kN)*
M8 10 80 15 10 35 50 6.5 4.4
M10 12 90 25 20 40 60 9.0 7.1
M12 14 110 30 40 50 70 13.1 10.5
M16 18 125 40 95 65 100 18.8 19.9
M20 24 150 75 180 80 120 26.7 30
M20 24 170 75 180 80 120 30.3 30
M24 26 160 105 315 100 145 32.2 43.4
M24 26 210 105 315 100 145 42.2 43.4
Bold working load values in tension are limited by steel. All other values limited by concrete and adhesive bond
* For shear acting towards a concrete edge please contact a Ramset Engineer for further design assistance
All values are for Grade 5.8 carbon steel.
** reduced load factor applies
For load capacity data according to ETA standards consult ETA reports
Structaset 402™
- Indicative Working Loads in 32 MPa Concrete with Reinforcing Bar
Thread
Size
Drilled size
(mm)
Min Hole
Depth (mm)
Min Edge Distance
(mm)
Min Anchor Spacing
(mm)
Max Tensile
Load, Na (kN)
Max Shear Load,
Vas (kN)* Grade 500
N10 14 90 40 60 5.8 9.7
N12 16 110 50 70 8.5 14.0
N16 20 125 65 100 12.3 24.9
N20 25 150 80 120 19.4 38.9
N24 30 160 100 145 24.8 56
N24 30 210 100 145 32.5 56
N32 40 255 130 195 52.7 99.7
N32 40 300 130 195 62 99.7
Working load capacity was derived from characteristic
ultimate load capacity by applying the following factors:
Tension: Concrete = 3, Steel = 2.2
Shear: Steel = 2.5
Hole Condition
Hole Condition Suitable
Dry Yes
Damp Yes
Wet Yes
Flooded** Yes
Drill Bit Type
Carbide Yes
Hole Orientation
Vertical Down Yes
Horizontal Yes
Vertical Up (Overhead) Yes*
Structaset 402™
Anchoring Adhesive
Description Part No Box Quantity
Structaset 402 (350 ml) + 1 Nozzle S402M350 12
Dispensing Tool (350ml 10:1 ) CD350101 1
For installation accessories see page 12-13
Working and Loading Time
Substrate Temperature
(°C)
Gel Time
(min)
Cure Time
(hours)
10 - 15 20 12
15 - 20 15 5
20 - 25 10 145 mins
25 - 30 7.5 85 mins
30 - 35 5 50 mins
35 - 40 3.5 40 mins
40 - 45 2 40 mins
Recommended Installation Temperatures
Minimum Maximum
Substrate 10°C 45°C
Adhesive 20°C 45°C
Refer to Technical Data Sheet and MSDS.
For precautions and further detailed installation instructions
Application test on-site before use is recomended. Consult technical data reports before commencing use.
8. CONSTRUCTION SYSTEMS INDIA8
ChemSet 102™
General Purpose Chemical Anchor
Typical Properties
Properties Typical Value
Appearance Part A: Cream Part B: Black
Mixed: Grey
Density 1.69 kg /litre @ 20°C
Heat Distortion Temperature Approx. 80°C
Hardness > Shore D 80
Compressive Strength
(AS1012.9)
70 MPa
Service Temperature Limits -10°C to 80°C
Substrates Solid Concrete, Solid Stone (Proof loading
recommended), Solid Brick, Hollow
Concrete Block, Hollow Brick
Description
Fast cure, medium duty anchoring of threaded studs and reinforcing bar into
solid concrete, stone, hollow brick and hollow concrete block.
Versatile, multi-purpose two part polyester anchoring system.
Use in standard silicone caulking gun. Suitable for general purpose anchoring
such as Steel fencing, gates, brackets, hinges, guard rails, hand rails
Features & Benefits
• Extended working time in hot weather
• Sag resistant formula for horizontal holes
and overhead applications
• Low odour
• Solid and hollow substrates
• Easy dispensing
• Fits standard silicone caulking gun
• Dry, wet or flooded holes
• Green building and VOC compliant
• Same day loading of anchors
Trades & Applications
Concreter Building
Contractor
Civil
Contractor
Steel
Fabricator
Balustrade
Contractor
Formworker Bricklayer Fitter Seating
Contractor
Threaded Studs 4 4 4 4 4
Rod Bars 4 4 4 4 4
Hollow Masonry
Sleeves
4 4 4 4
Related Products
DynaDrill™
Carbide Drill Bits
Impact Wrench
Wet/Dry Vacuum
Hole Cleaning Brushes
Hole Cleaning Pump
Standard Cartridge Dispensing Tool
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Fire
Resistant
ETA Option 7
TR029
VOC
Compliant
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Styrene
Free
LEED
TESTED
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Loading
Resitant
Pull down
feature
Close to
edge
Cracked
Concrete
ZINC Galvanised Stainless
Steel 316
Hot dipped
Galvanised
Stainless
Steel
Zinc Plated
ETA
European Technical Approval
9. CONSTRUCTION SYSTEMS INDIA9
ChemSet 102™
General Purpose Chemical Anchor
Recommended Installation Temperatures
Minimum Maximum
Substrate 10°C 45°C
Adhesive 10°C 45°C
Working and Loading Time
Substrate Temperature
(°C)
Working Time
(min)
Cure / Loading Time
(min)
45 2.5 12
40-44 3.5 35
35-39 5.0 40
30-34 7.5 50
25-29 10 85
20-24 15 145
Chemset 102™
Anchoring Adhesive
Description Part No Box Quantity
Cartridge (300 ml) + 2 Nozzles C102300 12
Chemset 102™
- Indicative Working Loads in 32 MPa Concrete with ChemSet™
Anchor Studs
Thread
Size
Drilled Hole
Ø (mm)
Min Hole
Depth (mm)
Max Fixture
Thickness (mm)
Tightening
Torque (Nm)
Min Edge
Distance (mm)
Min Anchor
Spacing (mm)
Max Tensile
Load, Na (kN)
Max Shear
Load, Vas (kN)*
M8 10 80 15 10 30 50 4.5 4.4
M10 12 90 25 20 40 60 6.0 7.1
M12 14 110 30 40 50 70 8.6 10.5
M16 18 125 40 95 65 100 13.5 19.9
M20 24 150 75 180 80 120 22.3 30
M20 24 170 75 180 80 120 25.2 30
M24 26 160 105 315 100 145 32.7 43.3
M24 26 210 105 315 100 145 42.9 43.3
Bold working load values in tension are limited by steel. All other values limited by concrete and adhesive bond
* For shear acting towards a concrete edge please contact a Ramset Engineer for further design assistance
Shear values are for Grade 5.8 carbon steel.
For load capacity data according to ETA standards consult ETA reports
Hole Condition
Hole Condition Suitable
Dry Yes
Damp Yes
Wet Yes
Flooded Yes
Drill Bit Type
Carbide Yes
Diamond Core No
Hole Orientation
Vertical Down Yes
Horizontal Yes
Vertical Up (Overhead) Yes
Installation in Solid Concrete
1. Drill hole to specified diameter and depth
2. Remove dust and debris by brushing and blowing 3 times each (If hole is
wet or flooded, remove excess water with wet/dry vacuum)
3. Screw mixing nozzle onto cartridge and dispense 2-3 trigger pulls of
adhesive to waste until colour is grey with no streaks
4. Insert tip of nozzle to bottom of hole and dispense adhesive
5. Fill hole to about 2/3 full
6. Insert threaded stud or reinforcing bar with rotating motion to release
trapped air
7. Wait until adhesive has fully cured before loading
(see Working / Loading Time chart below)
8. Clean up with acetone
Note: For hollow brick and block installations, perforated nylon or
metal mesh sleave accessories must be used in conjunction with
chemical anchor.
Working load capacity was derived from characteristic
ultimate load capacity by applying the following factors:
Tension: Concrete = 3, Steel = 2.2
Shear: Steel = 2.5
For installation accessories see page 12-13
Application test on-site before use is recomended. Consult technical data reports before commencing use.
10. CONSTRUCTION SYSTEMS INDIA10
Maxima™
Chemical Capsule Anchor
Typical Properties
Properties Typical Value
Appearance Part A: Clear Honey
Part B: White Powder
Mixed: Dark Grey
Service Temperature Limits -23°C to 60°C
Substrates Solid Concrete, Solis Stone (Proof
loading recommended), Solid Brick
Features & Benefits
• Non-drip formula for horizontal holes and overhead applications
• Glass becomes part of the aggregate
• No applicator tool required
• Strong bond for extra security
• No mixing, no waste
• One capsule per fixing
• Use underwater
Description
Fast cure, extra heavy duty anchoring of threaded studs into solid concrete
and stone. For small jobs with few fixings. One capsule for one hole - no
mixing, no mess, no waste. Carbide, diamond drilled holes, Dry, wet or
underwater holes. Suitable for installation of Balustrade posts, fencing,
sheds, structural steel columns, hand rails, seating, machinery hold down.
Trades & Applications
Building
Contractor
Civil Contractor Steel Fabricator Balustrade
Contractor
Fitter Seating Contractor
Threaded Studs 4 4 4 4 4 4
Related Products
DynaDrill™
Carbide Drill Bits
Diamond Motor
Diamond Core Drill Bits
Impact Driver
Wet/Dry Vacuum
Hole Cleaning Brushes
Hole Cleaning Pump
VOC
Compliant
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Fire
Resistant
ETA Option 7
Hot dipped
Galvanised
Stainless
Steel
Zinc Plated
ETA
European Technical Approval
11. CONSTRUCTION SYSTEMS INDIA11
Maxima™
Chemical Capsule Anchor
Hole Condition
Hole Condition Suitable
Dry Yes
Damp Yes
Wet Yes
Flooded Yes
Drill Bit Type
Carbide Yes
Diamond Core Yes
Hole Orientation
Vertical Down Yes
Horizontal Yes
Vertical Up (Overhead) Yes
Working and Loading Time
Substrate
Temperature (°C)
Gel Time
(min)
Cure / Loading Time
(min)
Dry Damp or Wet
≥ 20 15 20 40
10 to 20 25 30 60
0 to 10 45 60 120
-5 to 0 60 5 hours 10 hours
Recommended Installation Temperatures
Minimum Maximum
Substrate -5°C 43°C
Adhesive -5°C 43°C
ChemSet™
Maxima™
Anchoring Capsule
Description Part No Box Quantity
ChemSet™
Maxima™
Capsule M8 CHEM08 10
ChemSet™
Maxima™
Capsule M10 CHEM10 10
ChemSet™
Maxima™
Capsule M12 CHEM12 10
ChemSet™
Maxima™
Capsule M16 CHEM16 10
ChemSet™
Maxima™
Capsule M20 CHEM2024 6
ChemSet™
Maxima™
Capsule M24 CHEM2024 6
ChemSet™
Maxima™
- Indicative Working Loads in 32 MPa Concrete with ChemSet™
Anchor Studs
Thread
Size
Drilled Hole
Ø (mm)
Min Hole
Depth (mm)
Tightening
Torque (Nm)
Min Edge
Distance (mm)
Min Anchor
Spacing (mm)
Max Tensile
Load, Na (kN)
Max Shear
Load, Vas (kN)*
M8 10 80 10 35 50 6.5 4.4
M10 12 90 20 40 60 10.3 7.1
M12 14 110 40 50 75 15.3 10.5
M16 18 125 95 65 100 22.3 19.9
M20 24 150 180 80 120 35.7 29.9
M20 24 **170 180 80 120 40.5 29.9
M24 26 160 315 100 145 41.3 43.3
M24 26 **210 315 100 145 54.2 43.3
Bold working load values in tension are limited by steel. All other values limited by concrete and adhesive bond
* For shear acting towards a concrete edge please contact a Ramset Engineer for further design assistance
Shear values are for Grade 5.8 carbon steel.
** Note: To acheive these non standard effective depths use an additional CHEM08 Maxima Capsule per hole.
For load capacity data according to ETA standards consult ETA reports
Installation in Solid Concrete
1. Drill hole to specified diameter and depth
2. Remove dust and debris by brushing and blowing 3 times each (If hole is
wet or flooded, brush only)
3. Insert capsule into hole
4. Fit socket into drill and use to rotate and drive a ChemSet™ Anchor
Stud into the hole
5. The stud rotation will mix the capsule contents
6. Wait until adhesive has fully cured before loading (see Loading Time
chart below)
Refer to Technical Data Sheet and MSDS for precautions and further
detailed installation instructions
Description Part No Box Quantity
Hole Cleaning Pump HCP 1
Hole Cleaning Pump High Volume HCPHV 1
Hole Cleaning Brush 13 mm HCBT13 1
Hole Cleaning Brush 20 mm HCBT20 1
Hole Cleaning Brush 26 mm HCBT26 1
Working load capacity was derived from characteristic
ultimate load capacity by applying the following factors:
Tension: Concrete = 3, Steel = 2.2
Shear: Steel = 2.5
Application test on-site before use is recomended. Consult technical data reports before commencing use.
12. CONSTRUCTION SYSTEMS INDIA12
Chemical Anchor Consumables
Description
ChemSet™
Anchoring Studs are made from Grade 5.8 carbon steel to
maximise adhesive tensile capacities and provide higher shear capacities
than regular Grade 4.6 grade studs. Stainless Steel ChemSet™
Anchor Studs
are high corrosion resistant AISI 316 (A4).
Features and Benefits
• High Performance Grade 5.8 Carbon Steel
• Zinc Plated for indoor or dry climates
• Hot dip galvanised to AS1650 and AS1214
• Hot dip galvanised to 42 micron for exterior applications
• High Performance AISI316 Stainless Steel for Coastal Applications
• Pre-cut to standard chemical anchoring lengths
• Supplied with nuts and washers
• Depth set mark to ensure correct embedment
• Reliable external hex drive for installing capsules
• Ramset™
Quality
ChemSet™
Anchor Studs - Typical Properties
See working loads of each anchoring adhesive in previous pages
Thread
Size
Overall
Length, L
(mm)
Drill bit
Diameter
(mm)
Min hole
depth
(mm)
Effective
Length, Le
(mm)
Max Fixture
Thickness, t
(mm)
Yield
Strength, fy
(MPa)
Carbon
Steel UTS, fu
(MPa)
Yield
Strength, fy
(MPa)
Stainless
Steel UTS, fu
(MPa)
Section
Modulus, Z
(mm3)
M8 110 10 80 95 15 430 540 450 650 31.2
M10 130 12 90 115 25 430 540 450 650 62.3
M12 160 14 110 140 30 430 540 450 650 109.2
M12 180 14 110 160 50 430 540 450 650 109.2
M16 190 18 125 165 40 420 520 450 650 277.5
M20 260 24 150 225 80 420 520 450 650 540.9
M24 300 26 160 265 105 420 520 450 650 935.5
Installation
See recommendations for each Chemical anchoring adhesive
on previous pages.
ChemSet™
Anchor Studs
Description Zinc Hot Dip Galvanised Stainless Steel 316 A4 Box Quantity
ChemSet™
Anchor Stud M8 x 110 CS08110 CS08110GH CS08110SS 10
ChemSet™
Anchor Stud M10 x 130 CS10130 CS10130GH CS10130SS 10
ChemSet™
Anchor Stud M12 x 160 CS12160 CS12160GH CS12160SS 10
ChemSet™
Anchor Stud M16 x 190 CS16190 CS16190GH CS16190SS 10
ChemSet™
Anchor Stud M20 x 260 CS20260 CS20260GH CS20260SS 6
ChemSet™
Anchor Stud M24 x 300 CS24300 CS24300GH CS24300SS 6
Specification
Material - Bolt Carbon Steel, Stainless Steel 316 (A4)
Corrosion Protection Zinc Plating, Hot Dipped Galvanising
Stainless Steel 316 (A4)
Head Styles Hex Nut
Fixing Method Through Fixture
Setting Method Chemical
Anchoring Method Chemical
Thread Diameters M8, M10, M12, M16, M20, M24
Anchor/Hole Diameters 10mm, 12mm, 14mm, 18mm, 24mm, 26mm
Anchor Lengths 110mm, 130mm, 160mm, 190mm, 260mm,
300mm
Maximum Fixture Thickness’ 15mm, 25mm, 30mm, 50mm, 40mm,
45mm, 80mm, 90mm, 105mm
Substrates Concrete, Solid Brickwork
Note: Some studs supplied to special order. Lead times apply.
13. CONSTRUCTION SYSTEMS INDIA13
Chemical Anchor Consumables
Installation Accessories
Hole Cleaning Pump Hole Cleaning Brushes
Standard High Volume M12 M20 M26 M36 M40
HCP HCPHV HCBT13 (13x200mm) HCBT20 (20x300mm) HCBT26 (26x310mm) - -
- - - HCBT201000 (20x1000mm) HCBT261000 (26x1000mm) HCBT361000 (36x1000mm) HCBT421000 (42x1000mm)
- - 8 – 12 mm Dia Holes 16 – 20 mm Dia Holes 20 – 24 mm Dia Holes 32 –36 mm Dia Holes 38 – 42 mm Dia Holes
Hole Cleaning Accessories
Cleaning dust and debris from holes is necessary to obtain full adhesion and load capacity from Chemical Anchors.
• A full range of hole cleaning accessories are available for Chemical Anchoring products
• To remove dust and debris after drilling
• Removing dust ensures rated load capacities are achieved
Mixing Nozzles & Dispensers
Always use recommended mixing nozzles for each adhesive. Using the incorrect nozzle may result in improper mixing and poor load performance.
Description Part Number To Suit Length Length with Extension Pack Quantity
Mixing Nozzles (Epoxy) ISNE REO502, Structaset402 255mm 440mm 5
Fast Dispensing Nozzles - Turbo ISNET REO502, Structaset402 440mm - 1
Mixing Nozzles (Polyester) ISNP Chemset102 215mm - 5
Dispensing Tool 600ml (1:1) CD60011 REO502M600 - - 1
Dispensing Tool 400ml (1:1) CD40011 REO502M400 - - 1
Dispensing Tool 350ml (10:1) CD350101 Structaset402 - - 1
Dispensing Tool 600ml (1:1) CRA REO502M600 - - 1
ISNP ISNE ISNET
HCP Dispenser CD60011 Dispenser CD40011 Dispenser CD350101HCPHVHCBT13, HCBT20, HCBT26
14. CONSTRUCTION SYSTEMS INDIA14
Triga Z™
Specification Anchor ( Hi-Tensile )
Specification
Material - Bolt Class 8.8 High Tensile Carbon Steel
( 316 (A4) Stainless Steel to special order )
Corrosion Protection Zinc Plating, Stainless Steel 316 A4
Head Styles Hex or Countersunk
Fixing Method Through Fixture
Setting Method Torque Controlled
Anchoring Method Expansion
Thread Diameters M10, M12, M16, M20
Drilled Hole Diameters 15mm,18mm, 24mm, 28mm
Anchor Lengths 105mm, 120mm, 145mm, 170mm
Maximum Fixture Thickness 10mm, 20mm, 25mm, 27mm, 40mm
Indicative Recommended Max Tensile - refer table
Loads in 20MPa Concrete* Max Shear - refer table
Substrates Concrete
Features & Benefits
• The combination of a high tensile class 8.8 bolt with an extra thick-walled
spacer allows a smaller diameter bolt to be used for easier installation
while still providing both excellent tensile and shear performance.
The spacer also incorporates a visual maximum fixture thickness
indicator for ease of use.
• The patented anti-rotation expansion sleeve is designed with sharp angled
protrusions that grip the sides of the hole, preventing anchor rotation
during installation. As expansion of the sleeve begins, the locking barbs
also grip the sides of the hole, further embedding as expansion
progresses, giving extra holding power. The sleeve pulls down during
tightening ensuring excellent pressure between the fixture and the
concrete.
• The low profile hex or countersunk heads provide a neat finish.
Related Products
DynaDrill™
Carbide Drill Bits
Diamond Motor
High tensile class 8.8 bolt with
extra thick-walled spacer and
maximum fixture thickness indicator
Patented anti-rotation expansion
sleeve with pull-down section
and locking barbs
Low profile hex or
Countersunk head
Description
The Triga Z™
Anchor is a heavy duty, torque controlled expansion anchor, with
an integrated pull-down section, designed for high performance in both static
and dynamic load applications, in both cracked and
non-cracked concrete. The Triga Z™
Anchor is ideally suited for through fixing
into concrete when security and reliability are paramount.
~
Whether a concrete element is classified as cracked or non-cracked is to be determined
by a qualified structural engineer.
Hole Cleaning Brush
Hole Cleaning Pump
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Cracked
Concrete
Fire
Resistant
Seismic Zinc Plated Stainless
Steel
ETA Option 1
Cracked Concrete
Fire tested TR020
ETA
European Technical Approval
15. CONSTRUCTION SYSTEMS INDIA15
Triga Z™
Specification Anchor ( Hi-Tensile )
Trades & Applications
Steel Maintenance Plumbing Electrical Construction Elevator
Fabricator Fitter Contractor Contractor Contractor Installer
Anchoring structural steel columns/beams 4
Anchoring HVAC units 4 4
Machinery hold down 4
Anchoring safety rails and steel plates 4 4 4 4 4 4
Anchoring Elevator Guide Rails 4
Installation
1. Drill a hole to the recommended diameter and depth using the
fixture as a template. Clean the hole thoroughly with a hole cleaning brush.
Remove the debris with a hand pump, compressed air, or vacuum.
2. After ensuring that the anchor is assembled correctly, insert the anchor
through the fixture and drive with a hammer until the washer contacts
the fixture.
3. Tighten the bolt with a torque wrench to the specified assembly torque.
Triga Z™
Specification Anchor - Hex Bolt - Zinc Plated
Part No Thread Max Fixture Overall Anchor Drilled Hole Fixture Hole Min Hole Order
Size Thickness (mm) Length (mm) Ø (mm) Ø (mm) Depth (mm) Qty
050689 M10 20 105 15 17 105 25
050696 M12 10 105 18 20 110 25
050697 M12 25 120 18 20 120 25
050705 M16 25 145 24 26 146 10
050711 M20 25 170 28 31 167 5
Triga Z™
Specification Anchor - Countersunk Head - Zinc Plated
Part No Thread Max Fixture Overall Anchor Drilled Hole Fixture Hole Min Hole Order
Size Thickness (mm) Length (mm) Ø (mm) Ø (mm) Depth (mm) Qty
050695 M10 27 105 15 17 90 25
050715 M12 40 130 18 20 105 10
Triga Z™
Specification Anchor - Indicative Recommended Loads in 20MPa Concrete
Thread Embedment Tightening Min Edge Min Anchor Max Tensile Max Shear
Size Depth (mm) Torque (Nm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
M10 70 50 105 210 17.1 20.8
M12 80 80 120 240 16.3 29.7
M16 100 120 150 300 29.5 62.9
M20 125 200 190 375 40.9 71.4
Triga Z™
Specification Anchor - Hex Bolt - Stainless Steel Grade AISI 316 (A4)
Part No Thread Max Fixture Overall Anchor Drilled Hole Fixture Hole Min Hole Order
Size Thickness (mm) Length (mm) Ø (mm) Ø (mm) Depth (mm) Qty
050601 M10 25 115 15 17 90 25
050605 M12 25 120 18 20 105 25
052940* M16 25 157 24 26 130 10
Available to special order. Lead times apply.
Stainless Steel version without ETA approvals.
*Hex nut assembly
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
For load capacity data according to ETA standards consult ETA reports
16. CONSTRUCTION SYSTEMS INDIA16
Fix Z™
Specification Stud Anchor
Features & Benefits
• The Fix Z™
Stud Anchor diameter equals the required hole diameter
providing maximum shear capacity for hole size and making drill bit
selection simple. Its cold forged construction ensures superior strength
and reliability.
• The anchor design ensures maximum expansion of the sleeve and
pull-down on the fixture. These actions are both further assisted by the
application of load.
• The anti-rotation expansion sleeve is designed to grip the sides of the hole,
preventing anchor rotation during installation.
Anchor diameter
equals Hole diameter
Anti-rotation expansion sleeve
Description
The Fix Z™
Stud Anchor is a true-to-size, heavy duty, torque controlled
expansion anchor, for permanent anchoring into standard and hard concrete.
Designed for heavy duty anchoring in cracked and non cracked concrete.
Suitable for seismic and fire environments.
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Pump
Hole Cleaning Brush
Specification
Material - Bolt Carbon Steel, Stainless Steel 316 A4
Corrosion Protection Zinc, Stainless Steel 316 A4
Head Styles Hex Nut
Fixing Method Through Fixture
Setting Method Torque Controlled
Anchoring Method Expansion
Thread Diameters M10, M12, M16
Drilled Hole Diameters 10mm, 12mm, 16mm
Anchor Lengths Refer table
Maximum Fixture Thickness Refer table
Indicative Recommended Loads Refer table
in 20MPa Concrete
Substrates Concrete
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Cracked
Concrete
Fire
Resistant
Seismic Stainless
Steel
ETA Option 1
Cracked Concrete
Fire tested TR020
Zinc Plated
ETA
European Technical Approval
17. CONSTRUCTION SYSTEMS INDIA17
Fix Z™
Specification Stud Anchor
Installation
1. Drill a hole to the recommended diameter and depth using the fixture as a
template. Clean the hole thoroughly with a hole cleaning brush. Remove the
debris with a hand pump, compressed air, or vacuum.
2. Insert the anchor through the fixture and drive with a hammer until the
washer contacts the fixture.
3. Tighten the nut with a torque wrench to the specified assembly torque.
Fix Z™ Stud Anchor - Hex Nut
Part No Part No Thread Max Fixture Overall Anchor Drilled Hole Fixture Hole Min Hole Order
Zinc Stainless Steel Size Thickness (mm) Length (mm) Ø (mm) Ø (mm) Depth (mm) Qty
056370 - M10 25 85 10 12 93 50
- 054630 M10 15 75 10 12 82 50
056380 054640 M10 36 95 10 12 93 50
- 050442 M10 60 120 10 12 96 25
056390 - M10 64 140 10 12 112 25
055337 055345 M12 25 100 12 14 113 25
055393 055394 M12 40 115 12 14 108 25
056620 054680 M12 65 140 12 14 118 25
056630 - M12 105 180 12 14 133 25
- 050443 M16 30 125 16 18 137 20
056670 - M16 30 135 16 18 147 20
- 054700 M16 55 150 16 18 142 10
056680 050444- M16 55 170 16 18 162 10
Trades & Applications
Steel Elevator Construction Seating Racking
Fabricator Installer Contractor Contractor Installer
Installing curtain walls, balustrades & barriers 4 4
Anchoring elevator guide rails 4 4
Anchoring structural steel columns/beams 4 4 4 4
Staduim seating & Pallet racking 4 4
Overhead suspensions and anchoring 4 4
Fix Z™ Stud Anchor - Indicative Recommended Loads in 20MPa Concrete - Zinc Plated
Thread Embedment Tightening Min Edge Min Anchor Max Tensile Max Shear
Size Depth (mm) Torque (Nm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
M10 46 30 65 130 3.3 13.3
M12 58 50 70 150 3.9 17.9
M16 68 100 100 195 5.7 28.6
Fix Z™ Stud Anchor - Indicative Recommended Loads in 20MPa Concrete - Stainless Steel 316 A4
Thread Embedment Tightening Min Edge Min Anchor Max Tensile Max Shear
Size Depth (mm) Torque (Nm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
M10 42 30 65 130 4.7 11.9
M12 50 50 70 150 6.5 17.2
M16 64 100 100 195 11.5 20.4
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
18. CONSTRUCTION SYSTEMS INDIA18
Fix 3™
Multi Purpose Heavy Duty Stud Anchor
Features & Benefits
• The Fix 3™
Stud Anchor diameter equals the required hole diameter
providing maximum shear capacity for hole size and making drill bit
selection simple. Anchor dxesign provides superior strength
and reliability.
• The anchor design ensures maximum expansion of the sleeve and
pull-down on the fixture. These actions are both further assisted by the
application of load.
• The anti-rotation expansion sleeve is designed to grip the sides of the hole,
preventing anchor rotation during installation.
• Use threaded couplers where rod suspension applications are required.
• Suitable for installation in concrete from 80mm thick such as
pre-fabricated concrete panels.
Suitable for concrete
thickness from 80mm
Reduced anchor edge distance and spacing.
More solutions for your applications.
No slot on the sleeve.
Better hole grip
Product ID: S FIX3 M10/36-26 (example)
M10 = Thread size metric.
36-26mm = Fixture thickness range
Conical sleeve assembly for
fast torque setting.
Fix 3 with hex coupler
for rod suspension
Undercut Shoulder on the
sleeve improves holding power
and load performance.
Description
The Fix 3™
Stud Anchor is a true-to-size, heavy duty, multi purpose
expansion anchor, for permanent anchoring into concrete. Designed for heavy
duty anchoring in non cracked concrete where reduced edge distance and
anchor spacing is required. Undercut shoulder on the sleeve improves hole
grip and increases load performance.
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Brush
Hole Cleaning Pump
Specification
Material - Bolt Carbon Steel
Corrosion Protection Zinc Plating
Head Styles Hex Nut
Fixing Method Through Fixture
Setting Method Torque Controlled
Anchoring Method Expansion
Thread Diameters M8, M10, M12, M16, M20
Drilled Hole Diameters 8mm, 10mm, 12mm, 16mm, 20mm
Anchor Lengths Refer table
Maximum Fixture Thickness Refer table
Indicative Recommended Refer table
Loads in 20MPa Concrete*
Substrates Concrete
* Refer to load table
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Fire
Resistant
ETA Option 7
M10 Anchors
Zinc Plated
ETA
European Technical Approval
19. CONSTRUCTION SYSTEMS INDIA19
Fix 3™
Multi Purpose Heavy Duty Stud Anchor
Fix 3™ Stud Anchor - Hex Nut - Zinc Plated
Part No Thread Max Fixture Overall Anchor Drilled Hole Fixture Hole Min Hole Order
Size Thickness (mm) Length (mm) Ø (mm) Ø (mm) Depth (mm) Qty
057450 M8 5 55 8 9 50 100
057451 M8 20 70 8 9 75 100
057453 M8 50 100 8 9 90 50
057455 M8 80 130 8 9 90 50
057461 M10 15 75 10 12 80 50
057463 M10 36 95 10 12 90 50
057465 M10 65 125 10 12 100 25
057467 M10 100 160 10 12 62 25
057470 M12 5 80 12 14 90 25
057471 M12 25 100 12 14 110 25
057472 M12 40 115 12 14 105 25
057474 M12 65 140 12 14 115 25
057476 M12 105 180 12 14 130 25
057480 M16 5 100 16 18 110 20
057481 M16 30 125 16 18 135 20
057482 M16 55 150 16 18 135 10
057490 M20 10 125 20 22 140 10
057491 M20 50 165 20 22 175 10
057492 M20 105 220 20 22 190 10
Trades & Applications
Steel Elevator Construction Seating Racking
Fabricator Installer Contractor Contractor Installer
Installing Curtain Walls, balustrades & barriers 4 4
Anchoring elevator guide rails 4 4
Anchoring structural steel columns/beams 4 4 4
Staduim seating & Pallet racking 4
Overhead suspension & Anchoring 4 4 4
Fix 3™ Stud Anchor - Indicative Recommended Loads in 20MPa Concrete - Zinc Plated
Thread Embedment Tightening Min Edge Min Anchor Max Tensile Max Shear
Size Depth (mm) Torque (Nm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
M8 30 15 45 90 3.5 5.7
M10 40 30 60 120 6.1 7.8
M12 50 50 75 150 8.5 15.7
M16 65 100 100 200 12.6 20.9
M20 75 160 115 225 15.6 33.9
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
Installation
1. Drill a hole to the recommended diameter and depth using the fixture as a
template. Clean the hole thoroughly with a hole cleaning brush. Remove the
debris with a hand pump, compressed air, or vacuum.
2. Insert the anchor through the fixture and drive with a hammer until the
washer contacts the fixture.
3. Tighten the nut with a torque wrench to the specified assembly torque.
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
20. CONSTRUCTION SYSTEMS INDIA20
Fix II™
Structural Stud Anchor (Galvanised)
Features & Benefits
• The Fix II™
Stud Anchor diameter equals the required hole diameter
providing maximum shear capacity for hole size and making drill bit
selection simple. Its cold forged construction ensures superior strength
and reliability.
• The anchor design ensures maximum expansion of the sleeve and
pull-down on the fixture. These actions are both further assisted by the
application of load.
• The anti-rotation expansion sleeve is designed to grip the sides of the hole,
preventing anchor rotation during installation.
Anchor diameter
equals Hole diameter
Anti-rotation expansion sleeve
Description
The Fix II™
Stud Anchor is a true-to-size, heavy duty, torque controlled
expansion anchor, for permanent anchoring into concrete. Designed for heavy
duty anchoring in standard and hard concrete structural applications.
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Pump
Hole Cleaning Brush
Specification
Material - Bolt Carbon Steel,
Corrosion Protection Hot Dipped Galvanising (45 micron)
Head Styles Hex Nut
Fixing Method Through Fixture
Setting Method Torque Controlled
Anchoring Method Expansion
Thread Diameters M10, M12, M16
Drilled Hole Diameters 10mm, 12mm, 16mm
Anchor Lengths Refer table
Maximum Fixture Thickness Refer table
Indicative Recommended Loads Refer table
in 20MPa Concrete
Substrates Concrete
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Fire
Resistant
Hot dipped
Galvanised
ETA Option 7
M10 x 40
M12 x 50
ETA
European Technical Approval
21. CONSTRUCTION SYSTEMS INDIA21
Fix II™
Structural Stud Anchor (Galvanised)
Installation
1. Drill a hole to the recommended diameter and depth using the fixture as a
template. Clean the hole thoroughly with a hole cleaning brush. Remove the
debris with a hand pump, compressed air, or vacuum.
2. Insert the anchor through the fixture and drive with a hammer until the
washer contacts the fixture.
3. Tighten the nut with a torque wrench to the specified assembly torque.
Fix II™ Stud Anchor - Hex Nut - Hot Dipped Galvanised
Part No Thread Max Fixture Overall Anchor Drilled Hole Fixture Hole Min Hole Order
Size Thickness (mm) Length (mm) Ø (mm) Ø (mm) Depth (mm) Qty
050350 M10 15 75 10 12 82 50
050360 M10 36 95 10 12 93 50
050340 M10 60 120 10 12 96 25
050341 M10 100 160 10 12 112 25
055352 M12 25 100 12 14 113 25
055395 M12 40 115 12 14 108 25
050400 M12 65 140 12 14 118 25
050410 M12 105 180 12 14 133 25
050440 M16 30 125 16 18 137 20
050354 M16 55 150 16 18 142 10
Trades & Applications
Steel Elevator Construction Seating Racking
Fabricator Installer Contractor Contractor Installer
Installing curtain walls, balustrades & barriers 4 4
Anchoring elevator guide rails 4 4
Anchoring structural steel columns/beams 4 4 4 4
Staduim seating & Pallet racking 4 4
Overhead suspensions and anchoring 4 4
Fix II™ Stud Anchor - Indicative Recommended Loads in 20MPa Concrete - Hot Dipped Galvanised
Thread Embedment Tightening Min Edge Min Anchor Max Tensile Max Shear
Size Depth (mm) Torque (Nm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
M10 42 30 65 130 3.9 8.9
M12 50 50 75 150 6.3 14.6
M16 64 100 100 195 9.0 17.4
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
22. CONSTRUCTION SYSTEMS INDIA22
Internal Threaded Drop in Anchors
Shallow embedment reduces risk of
striking rebar during hole drilling
Displacement setting allows the
anchor to remain in place without
insertion of machine bolt or
threaded rod
Dynaset Flanged
Without ETA or FM
approvals
Retaining Lip installs
anchor flush with
surface of substrate
Grip L Flanged
Specification
Material Carbon Steel, ( Stainless Steel 316 A4 to
special order)
Corrosion Protection Stainless Steel 316 A4, Zinc Plating
Head Style -
Fixing Method Fixture Aligned
Setting Method Displacement
Anchoring Method Expansion
Thread Sizes M10, M12, M16
Drilled Hole Diameters Refer table
Anchor Lengths Refer table
Maximum Fixture Thickness’ -
Indicative Working Refer table
Loads in 32MPa Concrete*
Substrates Concrete
Description
Internal threaded hammer set Drop-In Anchors are all steel, medium to
heavy duty, displacement setting, expansion anchors designed to provide a
permanent anchorage point in concrete. The internal thread allows it to be
used with both machine bolts and threaded rod, placing no restrictions on
fixture thickness. These anchors require the use of the correct setting tool
to ensure full expansion of the anchor body for maximum load performance.
The setting tool also acts as visual check for correct setting of the anchor.
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Brush
Hole Cleaning Pump
Setting Tool
Features & Benefits
• Drop in anchors fit flush with, or just below, the surface of the
substrate, leaving no protrusions when not in use and allowing for
easy patch work.
• The anchor’s internal thread facilitates the use of machine bolts and
threaded studs of any length, removing restrictions on fixture thickness.
• Requires shallow embedment, which reduces the risk of drilling into rebar.
• The setting tool provides a visual expansion check for correct setting of the
anchor.
• The flanged version (zinc plated only) has a retaining lip to keep the
anchor flush with the surface of the substrate. This also allows for
consistent threaded rod drop lengths.
Internally threaded
anchor places
no restrictions on
fixture thickness
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Fire
Resistant
Stainless
Steel
ETA Option 7
M10 x 40
M12 x 50
ETA
European Technical Approval
ETA
European Technical Approval
Zinc Plated
23. CONSTRUCTION SYSTEMS INDIA23
Internal Threaded Drop in Anchors
Installation
1. Drill a hole to the recommended diameter and depth. Clean the
hole thoroughly with a hole cleaning brush. Remove the debris with a hand
pump, compressed air, or vacuum.
2. Insert the anchor into the hole. Using a hammer and the appropriate
setting tool, drive the expansion plug into the anchor until the shoulder of
the tool rests against the surface of the anchor.
3. Position the fixture, insert the bolt or threaded rod and tighten with a
spanner.
Grip L Drop-in Anchors - Zinc Plated - Flanged
Part No Thread Thread Overall Anchor Drilled Hole Min Hole Setting Order
Size Length (mm) Length (mm) Ø (mm) Depth (mm) Tool Qty
050799 M10 11 30 12 33 051015 100
050792 M12 21 50 15 54 050925 50
050793 M16 28 65 20 70 050926 20
* For detailed technical data refer to ETA report * Available to special order, lead time apply * 316 A4 stainless steel available to special order
DynaSet™
Drop-in Anchors - Zinc Plated - Flanged
Part No Thread Thread Overall Anchor Drilled Hole Min Hole Setting Order
Size Length (mm) Length (mm) Ø (mm) Depth (mm) Tool Qty
DSF10BZ M10 14 30 12 33 SETDF3 50
DSF12BZ M12 21 50 16 53 SETDS4 50
DSF16BZ M16 28 65 20 68 SETDS5 25
Trades & Applications
Electrical & Plumbing Contractor Mechanical Services Contractor Ceiling & Partitioning Contractor
Electrical & Pipe Service Suspension 4
Mechanical Service Suspension 4
Ceiling Suspension 4
DynaSet™
Drop-in Anchors - Stainless Steel AISI 316(A4) - Straight
Part No Thread Thread Overall Anchor Drilled Hole Min Hole Setting Order
Size Length (mm) Length (mm) Ø (mm) Depth (mm) Tool Qty
DSM10SS M10 16 40 12 43 SETDS3 50
DSM12SS M12 21 50 15 53 SETDS4 50
DSM16SS M16 28 60 20 68 SETDS5 25
* Available to special order, lead time apply
DynaSet™
Drop-in Anchors - Indicative Working Loads in 32MPa Concrete
Thread Embedment Tightening Min Edge Min Anchor Max Tensile Max Shear
Size Depth (mm) Torque (Nm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
M10 Flanged 28 12 100 70 3.4 2.9
M12 48 40 170 120 7.7 6.6
M16 63 95 220 160 11.5 10.4
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
ETA
European Technical Approval
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
24. CONSTRUCTION SYSTEMS INDIA24
UDZ 6™
Hammer - in Wedge Anchor
Description
The UDZ 6™ hammer-in Wedge Anchor combines the principle of a stud
anchor with a simple hammer-in installation method and no tightening torque
required.
It expands automatically under the load of the application pulling the cone
into the expansion sleeve. UDZ 6™ is approved for non structural applica-
tions in cracked and non cracked concrete, hollow block and brick.
Features & Benefits
• Hammer-in method makes installation quick and easy.
• Full expansion of the anchor is evident when the head of the anchor sits
flush with the fitting or substrate.
• Once fully set, the UDZ 6™ becomes tamper resistant.
• The anchor’s large flat head prevents fixture pullover.
• Shallow embedment minimises inteference with steel reinforcing
• Uses include steel track and channel fixing, perforated strap installation,
metal fixtures and brackets
Specification
Material Carbon Steel
Corrosion Protection Zinc Plating
Head Style - Anchor Large Flat (12mm)
Fixing Method Hammer - in
Setting Method Impact
Anchoring Method Expansion
Drilled Hole Diameters 6mm
Anchor Lengths 35mm
Maximum Fixture Thickness 5mm
Substrates Concrete, Stone, Solid Brick, Solid Block,
Grout Filled Block, Hollow Brick, Hollow Block,
Hollow Slab
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Pump
Large flush head
Diameter 12mm
Suits fixture hole
7-8mm
Tamper proof once
installed
The barb grips the hole to prevent
the anchor from pulling out
The UDZ expands
automatically, pulls the
cone into the expansion
sleeve and expands
against the hole wall
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Cracked
Concrete
Fire
Resistant
Seismic Zinc Plated
ETA Option 1
Cracked Concrete
Fire tested TR020
ETA
European Technical Approval
25. CONSTRUCTION SYSTEMS INDIA25
UDZ 6™
Hammer - in Wedge Anchor
Installation
1. Drill a hole to the recommended diameter and depth using the fixture
as a template. Remove the debris with a hand pump, compressed air,
or vacuum.
2. Insert the anchor through the fixture until the flange of the anchor
contacts the fixture.
3. Hammer home the expansion anchor until the head is flush
with the fixture.
UDZ 6™
Hammer - in Anchor
Part No Anchor Max Fixture Overall Anchor Head Drilled Fixture Hole Min Hole Order
Size Thickness Length Ø Hole Ø Ø Depth Qty
(mm) (mm) (mm) (mm) (mm) (mm) (mm)
057228 6 5 35 12 6 7 40 200
Trades & Applications
Electrical Contractor General Builder Plumbing Contractor Mechanical Services
Metal profiles and fixtures 4 4 4 4
Sign Installation 4 4 4
Pipe/Conduit Saddle Installation 4 4 4
Steel Channel 4 4 4 4
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
UDZ 6™
Hammer - in Anchor - Indicative Working loads in 25mpa Concrete
Anchor Size/ Drilling Anchor Fixture Hole Maximum Recommended Safe Tensile
Hole Ø (mm) Depth (mm) Depth (mm) (mm) Fixture Thickness (mm) Load (25MPa)
6 50 30 7-8 5 70kg
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
26. CONSTRUCTION SYSTEMS INDIA26
PROLONG™
Universal Frame Anchor
3 anti-rotation zones for improved
hole grip anchoring
4 expansion legs hold the anchor
behind the second surface
Specification
Material - Sleeve Nylon
Material - Screw Carbon Steel, Stainless Steel 316 A4
Corrosion Protection - Screw Zinc Plating, Stainless Steel 316 A4
Head Style Hex Head with washer, countersunk flat
Fixing Method Through Fixture
Setting Method Rotation
Anchoring Method Interference Fit
Drilled Hole Diameters 10mm
Anchor Lengths 80mm, 100mm, 145mm
Maximum Fixture Thickness 10mm, 30mm, 75mm
Substrates Concrete, Stone, Solid Brick, Hollow Brick,
Solid Block, Hollow Block, Hollow Slab,
Lightweight Concrete (AAC) Block
Description
The Prolong™ Universal Frame Anchor with screw bolt is suitable for
multiple uses in concrete and masonry in non structural applications.
Approved for use in cracked and non cracked concrete, solid or hollow
masonry. Suitable for external installation where cladding or screen is
mounted in front of the anchor.
The Prolong™ Universal Frame Anchor is suitable for applications in a range
of operating temperatures.
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Brush
Hole Cleaning Pump
Impact Driver
Hex Sockets
Features & Benefits
• Versatile anchor for all materials including hollow blocks, brick and concrete
• Three anti-rotation zones for maximum grip.
• Installed through the fixture.
• High contact surface area in hollow materials.
• High shear load.
Countersunk sleeve
allows flush finish
broad loose washer
6 expansion legs hold
the anchor in front of the
second surface
PERFORMANCE RELATED MATERIAL SPECIFICATION
Cracked
Concrete
Fire
Resistant
Seismic Zinc Plated
ETAG020
10mm Ø
Cracked Concrete
Stainless
Steel
ETA
European Technical Approval
27. CONSTRUCTION SYSTEMS INDIA27
PROLONG™
Universal Frame Anchor
PROLONG™
Frame Anchors - Hex Head - Zinc Plated
Part No Anchor Max Fixture Overall Anchor Drilled Hole Min Hole Hex Socket Order
Size (mm) Thickness (mm) Length (mm) Dia (mm) Depth (mm) (mm) Qty
566668 10 10 80 10 90 13 50
566669 10 30 100 10 110 13 50
566671 10 75 145 10 155 13 50
* Supplied complete with hex screw and washer
PROLONG™
Frame Anchors - Countersunk Head - Zinc Plated
Part No Anchor Max Fixture Overall Anchor Drilled Hole Min Hole Torx Drive no. Order
Size (mm) Thickness (mm) Length (mm) Dia (mm) Depth (mm) Qty
566653 10 10 80 10 90 40 50
566654 10 30 100 10 110 40 50
566656 10 75 145 10 155 40 50
PROLONG™
Frame Anchors - Countersunk Head - Stainless Steel 316 A4
Part No Anchor Max Fixture Overall Anchor Drilled Hole Min Hole Torx Drive no. Order
Size (mm) Thickness (mm) Length (mm) Dia (mm) Depth (mm) Qty
566721 10 30 100 10 110 40 50
566722 10 45 115 10 125 40 50
566723 10 75 145 10 155 40 50
Installation PROLONG™
Frame Anchor
1. Drill a hole to the recommended diameter and depth using the fixture as a template. If the fixture
thickness is less than the maximum, increase the hole depth accordingly. Clean the hole thoroughly
with a hole cleaning brush. Remove the debris with a hand pump, compressed air, or vacuum.
2. Insert the anchor through the fixture and tap with a hammer until the collar of the anchor
contacts the fixture.
3. Tighten screw until the head of the screw is flush with the collar of the anchor.
Trades & Applications
General Builder Building Contractor Wall Cladding Installer Window/Door Installer
Anchoring Wall/Base Plates & Brackets 4 4 4
Fitting Door & Window Frames 4 4 4 4
Wall Joists and Cladding 4 4 4 4
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
PROLONG™
Frame Anchors - Technical Data - Indicative Working loads in 25mpa Concrete
Anchor Size/ Drilled Hole Tighten Recommended Safe Tensile Recommended Shear load
Hole Ø (mm) Dia (mm) Torque (Nm) Load (25MPa) Load (25MPa)
10 10 10 100kg 100kg
For load capacity data according to ETA standards consult ETA reports. These loads above are based on one anchor without edge or spacing influence.
TORX™ Drive
28. CONSTRUCTION SYSTEMS INDIA28
AnkaScrew™
Screw - in Anchor
Specification
Material High Carbon Steel
( Stainless Steel 316 A4 to special order)
Corrosion Protection Zinc Plating, Mechanical Galvanising
( Stainless Steel 316 A4 to special order)
Head Style Flanged Hex
Fixing Method Through Fixture
Setting Method Rotation
Anchoring Method Thread Forming
Drilled Hole Diameters 5mm, 6mm, 8mm, 10mm, 12mm, 16mm
Anchor Lengths Refer table
Maximum Fixture Thickness Refer table
Indicative Working Refer table
Loads in 32MPa Concrete*
Substrates Concrete, Solid Brick, Solid Block,
Hollow Block, Hollow Slab, Hollow Brick
Hardened high carbon
steel construction
Single self-tapping thread provides secure
anchorage over the full embedment of the
anchor without bursting the substrate
Thread helix angle requires less
setting torque
Features & Benefits
• The AnkaScrew™ is both fast and easy to install as it simply screws
into a pre-drilled hole.
• The AnkaScrew™ is even faster and easier to remove. It simply screws
out leaving an empty hole with no protruding metal parts to grind off.
• The AnkaScrew™ is ideal for close-to-edge and close-to-anchor
installation as its self-tapping, rotation setting method of installation is not
subject to any expansion pressure, therefore does not burst the substrate.
Description
The AnkaScrew™ Screw-In Anchor is a totally removable, medium duty,
rotation setting, thread forming anchor, ideal for either temporary or
permanent anchoring into substrates such as concrete, brick, hollow brick or
block. The AnkaScrew™ is particularly well suited to close-to-edge or close-
to-anchor fixing as it does not expand and burst the surrounding substrate.
Related Products
DynaDrill™
Carbide Drill Bits
Hole Cleaning Brush
Hole Cleaning Pump
Impact Wrench
Impact Sockets
Flanged hex head for
improved performance
PERFORMANCE RELATED MATERIAL SPECIFICATION
Dynamic
Load
Pull down Close to
edge
Fire
Resistant
Mechanical
Galvanised
Stainless
Steel
Removable
Temporary
Internal thread for
rod suspensions
AnkaScrew Rod
Suspension Anchor
Hex Head socket for fast installation.
Flanged washer hex head design strengthens and
braces the anchor head against side loading and
perpendicular forces
Hi-Lo thread design for correct
hole alignment and insertion
6mm drilled hole size
for fast installation
MGAL
Zinc Plated
29. CONSTRUCTION SYSTEMS INDIA29
AnkaScrew™
Screw - in Anchor
Trades & Applications
General Builder Construction Contractor Racking Installer Concrete Formworker
Bottom plates & Service Suspension 4 4 4 4
Temporary hand rails/safety barriers 4 4 4
Pallet racking 4
Formwork support 4 4 4
Installation
1. Drill a hole to the recommended diameter and depth using the
fixture as a template. Clean the hole thoroughly with a hole cleaning
brush. Remove the debris with a hand pump, compressed air, or vacuum.
2. Insert the AnkaScrew™ through the fixture and screw it into the hole with
either a socket wrench or an impact driver using slight pressure until the
self-tapping action begins.
3. Tighten the AnkaScrew™ until the fixture is held firm. If resistance is
experienced when tightening, unscrew the anchor one turn and re-tighten.
Ensure that you do not over tighten.
AnkaScrew™
Screw-In Anchors - Mechanically Galvanised - Hex Flanged Head
Part No. Anchor Maximum Overall Drilled Hole Fixture Hole Min Hole Effective Order
Size Fixture Anchor Ø Ø Depth Length Qty
(mm) Thickness (mm) Length (mm) (mm) (mm) (mm) (mm)
AS05030HGAL 5 5 30 5 7 30 28 100
AS06050HGAL 6 20 50 6 8 60 44 100
AS06075HGAL 6 45 75 6 8 65 69 100
AS08060HGAL 8 20 60 8 10 75 54 100
AS08075HGAL 8 35 75 8 10 75 69 100
AS08100HGAL 8 60 100 8 10 80 94 100
AS10060HGAL 10 10 60 10 12 80 54 50
AS10075HGAL 10 25 75 10 12 85 69 50
AS10100HGAL 10 50 100 10 12 95 94 50
AS12075HGAL 12 15 75 12 14 100 69 50
AS12100HGAL 12 40 100 12 14 110 94 50
AS12150HGAL 12 90 150 12 14 110 144 20
AnkaScrew™
Screw-In Anchors - Zinc Plated - Hex Flanged Head
AS16115 16 25 115 16 18 107 94 10
AS16140 16 50 140 16 18 107 144 10
316 A4 stainless steel AnkaScrews available to special order. Lead times apply.
AnkaScrew™
Screw-In Anchors - Indicative Recommended Loads in 32MPa Concrete
Anchor Size/ Embedment Min Edge Min Anchor Max Tensile Max Shear
Hole Ø (mm) Depth (mm) Distance (mm) Spacing (mm) Load, Na (kN)* Load, Va (kN)*
5 25 15 15 1.4 1.5
6 45 60 35 4.1 4.5
8 60 80 45 6.6 8.4
10 75 100 60 9.8 13.8
12 90 120 70 14.4 16.7
16 90 160 100 15.8 18
For indicative loads in 20MPa concrete multiply tensile load by 0.73 and shear load by 0.79
AnkaScrew™
Rod Flanged Head Suspension Anchor - Zinc Plated
Part No Description Internal Anchor Anchor Drilled Hole Min Hole Hex Socket Order
Thread Size Length Ø Depth Size Qty
(mm) (mm) (mm) (mm) (mm) (mm)
AS06035R10HBZ AnkaScrew™ Rod Flanged Head - M10 10 6 35 6 45 13 100
AS06035R12HBZ AnkaScrew™ Rod Flanged Head - M12 12 6 35 6 45 15 50
AnkaScrew™
Rod Flanged Head Suspension Anchor - 32MPa Concrete
Anchor Size/ Embedment Min Edge Min Anchor Safe Tensile
Hole Ø (mm) Depth (mm) Distance (mm) Spacing (mm) Load (32MPa)
6 35 25 50 225kg
*The design engineer should ensure the structural element is capable of supporting these loads.
For more detailed information consult technical data sheets.
30. CONSTRUCTION SYSTEMS INDIA30
TrakFast™
800 Premium Track Fixing Tool
Features & Benefits
• Massive 100J power – Consistent fixings even in extreme applications.
• 50 pin magazine – Reduces downtime in loading the magazine
• Battery Gauge – Avoid running out of battery power.
• Fuel Cell Gauge – Always know when to change fuel cells.
• Lithium Battery – Fast Charge, Long Life
• Tool-less Depth of Drive Adjustment
• Power Saving Technology – isolates battery when tool is not in use
• Optional 20 pin magazine for tight spaces.
• Easily removable fastener guide and magazine
• Greater tool clearance – Allows the tool to fit in close to edge applications.
• Greater track clearance – Allows the tool to fit in deep track, up to 57mm.
• Removable Support Leg – Ensures tool is at 90° to work surface
• Electronically controlled fuel injection – Ensures consistent power in a
wide temperature range.
• Low Maintenance. Designed to work in all conditions.
• Patented gas cylinder design
• No drilling required
Description
For fast, high volume, continuous fixing of steel track, channel and mesh in
all operating environments and substrate materials. The TrakFastTM
800 is the
most technologically advanced gas tool on the market with a compact design
that is well balanced for repetitive fixing applications. The new TrakFastTM
800
offers a number of innovative features allowing quicker, safer installation of
partitioning track, pest control mesh and formwork systems. With the 50 pin
magazine and extra power, the speed at which the TrakFastTM
800 is able to
perform installations provides tremendous savings in total installed cost.
Related Products
Drive Pins & Fuel Cells
Specifications
Weight 3.9kg
Height 520mm
Length 396mm
Magazine Capacity
50 (+3) pin magazine
Impact Force 100J
Actuation Pressure 5kg
Overdrive 4mm
Intermittent Operation 2 pins per second
Fuel Cell Life 600 pins (approx)
Battery Charge Capacity 3,000 pins (approx)
Battery Voltage 3.7V Lithium-ion
Battery Charge time 90mins (25mins for 500 fixings)
Power Regulation Automatic
Operating Temperature Range -5°C to 49°C
Substrates
Concrete, Composite Steel Decking, Solid Brick, Precast Concrete, Steel
Pre-stressed concrete, Hollow Block Wall, Reinforced Concrete, Reinforced
Prefabricated Concrete
Electronic
Fuel Injection
Compact &
Lightweight
Design
Removable
50 Pin Magazine
Lithium Battery
Battery & Fuel Gauge
Depth of Drive
adjustment
31. CONSTRUCTION SYSTEMS INDIA31
TrakFast™
800 Premium Track Fixing Tool
Standard Operating Procedure
Always read and understand the instruction manual before
attempting to operate a Gas Technology Tool.
1. First insert the fuel cell and battery into the tool.
2. Insert the collated fasteners into the magazine.
3. If the magnetic washer adaptor is fitted, the washer should be
placed in the adaptor without compressing the front end of the tool.
4. The tool should then be compressed against the work surface.
(Making sure that the tool is perpendicular to the work surface).
5. Once the tool is compressed the trigger can be actuated and the
fastener is driven through the material being fastened and into the
substrate.
TrakFast™
800
Part No Description Order Qty
TRAKFAST800
TrakFast™
800 Pulsa™
Gas Tool + 2 x Lithium-
Ion Batteries plus charger (018361)
1
Kit includes: TrakMaster™
800 Tool, high impact carry case, 2 batteries, battery charger, safety glasses and instruction manual.
Trades & Applications
Ceiling and Partitioning Formwork Pest Control
Contractor Contractor Contractor
Track to concrete 4
Track to steel 4
Plywood to steel 4
Sacrificial steel formwork to steel 4
Pest control mesh to concrete 4
Accessories
Part No Description Order Qty
018543 Pulsa 800 20 Pin Magazine 1
018544 Pulsa 800 50 Pin Magazine 1
018545 Pulsa 800 Lithium-ion Battery 1
018546 Pulsa 800 Lithium-ion Battery Charger 1
014641 Pulsa 800 Magnetic Washer Adaptor 1
018424 TrakFastTM
800 Fastener Guide 1
B20544L Gas Tool Degreaser and Lubricant 1
PA1613 Safety Glasses 1
Application test on-site before use is recomended.
Pulsa 800 Pin
Part No
Description Length Order Qty
P8HC615 Premium HC615 Pin (060524) 15mm 500
P8HC617 Premium HC617 Pin (060525) 17mm 500
P8HC622 Premium HC622 Pin (060526) 22mm 500
10 strip collation + 1 x Fuel Cell
Heavy Duty Pin Range for Steel and Hard Concrete Fixing
The Ramset™ range of Premium Drive Pins has been designed for steel, standard and hard concrete applications.
Specifications
Raw Material Carbon Steel
Corrosion Protection Zinc Mechanically Plated (Min coating 10µm)
Nominal Head Diameter 6.4mm
Nominal Shank Diameter 3.0mm / 2.7mm
Shear Strength 1200N/mm2
Tensile Strength 1950N/mm2
Hardness 53-56HRC
32. CONSTRUCTION SYSTEMS INDIA32
TrakFast™
TF1200Standard Track Fixing Tool
Features & Benefits
• Durable and reliable
• Off position to prevent draining the battery when tool is not in use
• Cordless - self powered, no set up time required
• Sequential actuation - safe operation
• Tool automatically resets piston
• Narrow nose and profile to reach inside deep leg track
• Soft cushioned grip
• Carrying case
• Mechanical fuel injection
Description
TrakFast™ TF1200 is a standard gas technology tool for fixing steel track or
channel to concrete or steel. The mechanical fuel injection system delivers
reliable performance in many operating environments. For fast installation of
partitioning and track, use the TrakFast™TF1200 gas tool to provide medium
to high volume repetitive fixing into a range of building materials.
Related Products
Drive Pins & Fuel Cells
Specifications
Weight 3.8kg
Height 450mm
Length 380mm
Magazine Capacity 40 (+2) pin magazine
Impact Force 77J
Actuation Pressure 5kg
Intermittent Operation 2 pins per second
Fuel Cell Life 1,100 pins (approx)
Battery Charge Capacity 3,000 pins (approx)
Battery Voltage 6V
Battery Charge time 2.5 hours
Power Regulation Automatic
Operating Temperature Range -5°C to 49°C
Substrates
Concrete, Composite Steel Decking, Solid Brick, Precast Concrete, Steel
Pre-stressed Concrete, Hollow Block Wall, Reinforced Concrete, Reinforced
Prefabricated Concrete
Mechanical
Fuel Injection40 Pin Magazine
Battery Off
Position
33. CONSTRUCTION SYSTEMS INDIA33
TrakFast™
TF1200Standard Track Fixing Tool
Accessories
Part No Description Order Qty
PA1613 Safety Glasses 1
B0092 Battery 1
B0020 Battery Charger 1
TFPS AC / DC Adaptor 1
TFGAS Replacement Fuel Cell 6
B20544L Gas Tool Degreaser and Lubricant 1
Standard Operating Procedure
Always read and understand the instruction manual before
attempting to operate a Gas Technology Tool.
1. First insert the fuel cell and battery into the tool.
2. Insert the collated fasteners into the magazine.
3. The tool should then be compressed against the work surface.
(Making sure that the tool is perpendicular to the work surface).
4. Once the tool is compressed the trigger can be actuated and the
fastener is driven through the material being fastened and into the
substrate.
TrakFast™
Part No Description Order Qty
TF1200 TrakFast™
TF1200 Tool + 2 batteries 1
Kit includes: TrakFast™
Tool, high impact carry case, 2 x batteries, battery charger, safety glasses and instruction manual
Trades & Applications
Ceiling & Partitioning
Contractor
Track to concrete 4
Track to steel 4
Application test on-site before use is recomended.
Part No Description Length Order Qty
FPP012S 12mm Heavy Duty Steel/Concrete 12mm 1000
FPP034S 20mm Heavy Duty Steel/Concrete 20mm 1000
10 strip collation + 1 x Fuel Cell. These pins and fuel are not suitable for use in the TrakFast™ 800 tool.
Heavy Duty Pin Range
Drive pin designed for fastening partitioning track to steel.
Specifications
Raw Material Carbon Steel
Corrosion Protection Zinc Electroplated (Minimum coating 5µm)
Nominal Head Diameter 6.4mm
Nominal Shank Diameter 3.0mm/2.7mm (Stepped Shank)
Shear Strength 1120N/mm2
Tensile Strength 1800N/mm2
Hardness 50-56HRC
34. CONSTRUCTION SYSTEMS INDIA34
InsulFast™
GT3 Premium Insulation Fixing Tool
InsulFast™
GT
Part No Description Order Qty
820300 InsulFast™
GT3 Pulsa™
Tool + 2 x Batteries (T3IF) 1
Kit includes: InsulFast™
GT Pulsa™
tool, high impact carry case, 2 x batteries, battery charger, safety
glasses, allen key, dust cover and instruction manual
Features & Benefits
• The fastest insulation fixing system
• Virtually no recoil!
• 3 times less cocking force required than explosive powered tools
• Faster install than explosive powered tools - lower in place cost
• Automatic power adjustment
• Fixes to concrete and steel without the need for adjustment
• Compatible with all major insulation types
• Low insertion force
• Textured face for compatibility with rendering applications
• Sizes to suit soft and rigid insulation from 25mm to 100mm
• Soft insulation with thickness greater than 100mm may be compressed.
Description
The fastest insulation fixing system! This new gas technology system
provides effortless overhead fixing of insulation with virtually no recoil.
The low tool compression force enhances user comfort.
Automatic power adjustment to suit substrate material.
Related Products
Drive Pins & Fuel Cells
Specifications
Weight 3.5kg
Height 363mm
Length 466mm
Impact Force 100J
Actuation Pressure 3.5kg
Intermittent Operation 1 pin per second
Fuel Cell Life 1,000 pins (approx)
Battery Charge Capacity 3,000 pins (approx)
Battery Voltage 6V
Battery Charge time 3 hour
Power Regulation Automatic
Operating Temperature Range -5°C to 49°C
Substrates
Concrete, Composite Steel Decking, Solid Brick, Precast Concrete, Steel
Pre-stressed Concrete, Hollow Block Wall, Reinforced Concrete, Reinforced
Prefabricated Concrete
Electronic
Fuel Injection
Compact &
Lightweight
Design
Low Compression Force
Belt Clip
100mm insulation fixing
Capacity
Virtually No Recoil
35. CONSTRUCTION SYSTEMS INDIA35
InsulFast™
GT3 Premium Insulation Fixing Tool
Insulation Fasteners for Concrete, Masonary and Steel
Part No.
Rigid Insulation Soft Insulation Fastener Order
InsulFastGT3
Thickness Thickness Colour Qty
T3IG625* 25mm 25mm – 30mm Natural (White) 400
T3IG625B* 25mm 25mm – 30mm Black 400
T3IG638* 38mm 38mm – 45mm Natural (White) 350
T3IG650 50mm 50 mm – 55mm Natural (White) 300
T3IG650B* 50mm 50 mm – 55mm Black 300
T3IG663* 60mm 60mm – 65mm Natural (White) 500
T3IG675 75mm 75mm – 85mm Natural (White) 250
T3IG675B* 75mm 75mm – 85mm Black 250
T3IG6100 100mm 100mm – 110mm Natural (White) 200
Fastener Specification
Fastener Body Material High Density Polyethylene (HDPE)
Holding Diameter 60 mm
Lengths Available 25 mm to 100 mm
Drive Pin Material Carbon Steel
Drive Pin Plating Mechanical Zinc Plate
Drive Pin Shear Strength 8.0 kN
The recommended load (kN) are calculated from the mean ultimate load and a factor of safety higher than 4. A minimum of 4 fixings per fastened unit are required.
As concrete composition varies jobsite testing is recommended.
Technical Load Data
Part No. Concrete Strength Tensile Working Load Limit WLL
T3IG625 to T3IG6100 25 – 45 MPa 0.15 kN
Extruded Polystyrene Polyester Fibreglass / Rockwool Expanded Polystyrene
Compatible Insulation
Polyurethane Foam
& Polyisocyanurate
Standard Operating Procedure
Always read and understand the instruction manual before attempting to
operate a Gas Technology Tool.
1. First insert the fuel cell and battery into the tool.
2. The insulation fastener should then be placed on the end of the
fastener guide without compressing the front end of the tool.
3. The insulation fastener should then be forced through the insulation by
pushing on the tool.
4. The tool should then be compressed against the work surface. (Mak-
ing sure that the tool is perpendicular to the work surface).
5. Once the tool is compressed, and the insulation fastener is in contact
with the work surface, the trigger can be actuated and the faster is
driven into the substrate securing the insulation fastener in place.
Trades & Applications
Insulation Ceiling & Partitioning
Installers Contractor
Insulation to concrete 4 4
Insulation to steel 4 4
Fuel Cells are included with all
fasteners.
*Other sizes and colours up to 100mm
in length are available on request.
Minimum order quantities and lead
times apply.
36. CONSTRUCTION SYSTEMS INDIA36
Cablemaster™
800 Premium Cable and Pipe Fixing Tool
Features & Benefits
• Battery Gauge – Helps avoid running out of battery power.
• Fuel Cell Gauge – Always know when to change fuel cells.
• Lithium Battery – Fast Charge, Long Life
• Tool-less Depth of Drive Adjustment
• Power Saving Technology – isolates battery when tool is not in use
• Compact design with 20 pin magazine – Allows the tool to fit in tight spaces
• Easily removable fastener guide and magazine
• Greater tool clearance – Allows the tool to fit in close to edge applications.
• Removable Support Leg – Ensures tool is at 90° to work surface for
optimum fixings
• Electronically controlled fuel injection – Ensures consistent power in a wide
temperature range.
• Low Maintenance. Designed to work in all conditions.
• Patented gas cylinder design
• No drilling required
Description
The CableMasterTM
800 is the most technologically advanced gas tool on the
market. The new CableMasterTM
800 offers a number of innovative features
allowing quicker, safer installation of a wide variety of clips for plumbing, data
and electrical installations. The speed at which the CableMasterTM
800 is able
to perform installations provides tremendous savings in total installed cost.
Related Products
Drive Pins & Fuel Cells
Contractor Packs
Specifications
Weight 3.8kg
Height 309mm
Length 396mm
Magazine Capacity
20 (+3) pin magazine,
Impact Force 82J
Actuation Pressure 5kg
Overdrive 4mm
Intermittent Operation 2 pins per second
Fuel Cell Life 750 pins (approx)
Battery Charge Capacity 3,000 pins (approx)
Battery Voltage 3.7V Lithium-Ion
Battery Charge time 90mins (25mins for 500 fixings)
Power Regulation Automatic
Operating Temperature Range -5°C to 49°C
Substrates
Concrete, Composite Steel Decking, Solid Brick, Precast Concrete, Steel
Pre-stressed Concrete, Hollow Block Wall, Reinforced Concrete, Reinforced
Prefabricated Concrete
Electronic
Fuel Injection
Lithium Battery
Battery & Fuel Gauge
Removable
20 Pin Magazine
Depth of Drive
adjustment Compact &
Lightweight
Design
37. CONSTRUCTION SYSTEMS INDIA37
Cablemaster™
800 Premium Cable and Pipe Fixing Tool
Accessories
Part No Description Order Qty
018543 Pulsa 800 20 Pin Magazine 1
018545 Pulsa 800 Lithium-ion Battery 1
018546 Pulsa 800 Lithium-ion Battery Charger 1
018423 CableMasterTM
800 Fastener Guide 1
B20544L Gas Tool Degreaser and Lubricant 1
PA1613 Safety Glasses 1
CS42025 Saddle Adaptor 20/25mm 1
Standard Operating Procedure
Always read and understand the instruction manual before attempting
to operate a Gas Technology Tool.
1. First insert the fuel cell and battery into the tool.
2. Insert the collated fasteners into the magazine.
3. The clip should then be placed on the end of the fastener guide
without compressing the front end of the tool.
4. The tool should then be compressed against the work surface.
(Making sure that the tool is perpendicular to the work surface).
5. Once the tool is compressed the trigger can be actuated and the
fastener is driven into the substrate securing the clip in place.
CableMaster™
800
Part No Description Order
Qty
CABLEMASTER800 CableMaster™
800 Pulsa™
Gas Tool + 2 x Lithium-Ion Batteries
(018360)
1
Kit includes: CableMaster™
800™
tool, high impact carry case, 2 x batteries, battery charger, safety glasses and instruction manual
Trades & Applications
Plumbing Electrical Fire &
Contractor Contractor Security
Permanent cable suspension to concrete and steel 4 4
Pipe suspension systems to concrete and steel 4
Fire and security cabling to concrete and steel 4 4
Temporary cable suspension to concrete and steel 4
Application test on-site before use is recomended.
Pulsa 800 Pin
Part No
Description Length Order Qty
P8HC615 Premium HC615 Pin (060524) 15mm 500
P8HC617 Premium HC617 Pin (060525) 17mm 500
P8HC622 Premium HC622 Pin (060526) 22mm 500
10 strip collation + 1 x Fuel Cell
Heavy Duty Pin Range for Steel and Hard Concrete Fixing
The Ramset™ range of Premium Drive Pins has been designed for steel and hard concrete applications.
Specifications
Raw Material Carbon Steel
Corrosion Protection Zinc Mechanically Plated (Min coating 10µm)
Nominal Head Diameter 6.4mm
Nominal Shank Diameter 3.0mm / 2.7mm
Shear Strength 1200N/mm2
Tensile Strength 1950N/mm2
Hardness 53-56HRC
39. CONSTRUCTION SYSTEMS INDIA39
DataLec™
Multi Purpose Data Cable Clip
Application test on-site before use is recomended.
Datalec™
Multi-purpose Data & Cable clips
Pulsa 800
Part No
Description Order
Qty
P8CPGDLHC617
DataLec™ Clip Contractor Pack
(Heavy duty pins 17mm)
(500xclips,HC617pins,cable ties
200mm x 4.8mm Black, Fuel cell)
1
P8CPGDLHC622
DataLec™ Clip Contractor Pack
(Heavy duty pins 22mm)
(500xclips,HC622pins, cable ties
200mm x 4.8mm Black, Fuel cell)
1
VEL1225
Hook and loop strap
12mm x 25metre Roll (optional extra)
1
Features & Benefits
• One clip for data and standard cable installations
• Multiple cable mounting positions
• Wide soft VELCRO®
style strap (12mm) or hard plastic tie compatible
• Parallel or multi-directional cable fixing
• Single and cable bundle installations
• Non abrasive support and protection of services
• Suits cable in conduit and small diameter pipe applications
• Fix to standard and hard concrete, hollow masonry block & steel formwork
Specifications
Raw Material HDPE, High impact ,Halogen free
Slot opening 14mm wide
Clip spacing recommendation from 0.3 to 1mtr (approx.) depending
on application
Dimensions (mm) 33W x33D x 14H
*NOTE: Testing concluded when clip pulled over pin head or strap/tie failed .Job site testing may be required before use to determine actual achievable job
site values. Results have been achieved using a CableMasterTM
tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed
and a new fixing set away from any spalled concrete. Tension load capacities are for static load situations only. Values shown represent a minimum factor of
safety of 3:1 against the ultimate capacity.Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, a minimum
of 3 fixings should be used per fastened unit. 1. Tested with Pricemark Cable Tie, # CT-76380NAT100 2. Tested with VELCRO Brand strap - 12mm VELCRO
@ 60mm overlap with 50mm diam bundle.
Description
DataLec™ Clip is a Multipurpose data and cable clip for the fast installation
of specialised and standard cables. Install Fibre Optic, Broadband, Cat5/6,
Audio visual and other specialised cables using soft VELCRO®
style straps
to correctly support and secure these cables without damage. For standard
electrical and power cabling installations hard plastic cable ties or soft
VELCRO®
style straps can be used to suit installation needs. This versatile
and strong clip design is suitable for the installation of multiple cable
bundles, multi-directional cable runs, small diameter conduits with cables
and plastic/metal pipes.
Pin Selection Guide
Substrate HC617 HC622
Hard Concrete >50MPa 4 4
Concrete <50MPa 4 4
Hollow Concrete Block k 4
Steel 4 4
Steel Decking 4 4
4 Suitable k Possible
Performance Table*
Width
Concrete compressive strength
20MPa 40MPa
Cable Tie (supplied) 4.8mm 5kg 7kg
Cable Tie1
7.6mm 12kg 15kg
VELCRO strap2
12mm 3kg 4kg
Installation Procedure
1. Gently insert clip mounting tip (centre of clip) into CableMaster™
tool nosepiece
2. Press clip against substrate, depress CableMaster™ tool
nosepiece and fix clip
3. Attach cable to DataLec™ clip with appropriate tie or strap for
the application
Optional Item VEL1225
VELCRO® is a registered trademark of Velcro Industries B. V.
Total tensile load capacity per DataLecTM
Clip - HC617 or HC622 Pins
40. CONSTRUCTION SYSTEMS INDIA40
ClipElec™
Cable and Pipe Clip
ClipElec™
All-purpose Cable Tie Clips
Pulsa 800
Part No
Description Order Qty
P8CPGCL
ClipElec™
Contractor Pack
(500 x clips, HC622 Pins, Fuel Cell, Cable Ties 200mm x 4.8mm Black)
1
P8CPGCLHC617
ClipElec™
Hard Concrete Contractor Pack
(500 x clips, HC617 Pins, Fuel Cell, Cable Ties 200mm x 4.8mm Black)
1
Features & Benefits
• ClipElec™ can be used for cable, conduit and tube work.
• Universal design allows cable ties up to 9mm wide.
• Designed with an in-built energy absorber for perfect embedment.
• Clips directly onto the CableMaster™ Pin Guide for one handed operation.
• Hands are a safe distance from the Pin Guide during installation.
• Can be used with the PulsaLift™ Pole to fix from the ground.
• No drilling required.
Specifications
Raw Material
Polypropylene copolymer,
high impact, halogen free.
UV resistant
Capacity Up to 9mm cable tie width.
Spacing Recommendation 0.5 & 1 metre (approx)
Fire Resistance Properties
Incandescent wire test
(regulation NFC 20-455) 750°C
passed - LCIE laboratory test
results N° 438 309
(December 1998)
Low Temperature Test No breakage at 0°C
Dimensions 32 x 37mm
*NOTE: Test concluded when clip pulled over pin head or cable tie failed. Job-site testing may be required to determine actual achievable job-site values.
Results have been achieved with a CableMaster™
tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed and a new
fixing set away from any spalled concrete. Tension loads provided are for static load situations only. Values represent a minimum factor of safety of 3:1 on the
lowest test results achieved. Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, however a minimum of 3
fixings per fastening unit should be used.
Description
ClipElec™ is an all purpose cable tie system that may be used for fixing
cable, conduit and pipes for a wide variety of electrical and plumbing
applications. This system is extremely versatile allowing for many different
sized cables, pipes and conduit to be secured. The ClipElec™ all purpose
cable tie system may be used with the 4.8mm supplied cable ties or with
other cable ties up to a maximum width of 9mm.
Installation Procedure
1. Simply clip the ClipElec to the tool pin guide.
2. Press against the substrate, press the trigger & the clip is fixed.
3. Install the tube or conduit with cable tie.
Pin Selection Guide
Substrate HC617 HC622
Hard Concrete >50MPa 4 4
Concrete <50MPa 4 4
Hollow Concrete Block k 4
Steel 4 4
Steel Decking 4 4
4 Suitable k Possible
Performance Table*
Pin
Load Capacity (Tension) - Concrete
Cable Tie Width 20MPa 32MPa
HC617 9mm 10kg 12kg
HC622 9mm 10kg 12kg
HC622 4.8mm 2.5kg 3.7kg
Application test on-site before use is recomended.
41. CONSTRUCTION SYSTEMS INDIA41
CTClip™
One Piece Clip with Strap
CTClip™
Pulsa 800
Part No
Description Pipe / Conduit Diameter Order Qty
P8CPGCT CTClip™
Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) 16 - 32mm 1
Performance Table*
Load Capacity (Tension) - Concrete
Pin 20MPa 32MPa
HC617 7kg 9kg
HC622 7kg 10kg
Specifications
Raw Material High impact, Nylon 66
Spacing Recommendation 0.5 & 1 metre (approx)
Fire Resistance Properties UL94HB Fire Test
Description
The CTClip™ is the all in one cable tie system. With the integral cable strap
the CTClip™ can be used for cable, conduit and tube work. Fast installation
of cables and pipes, no extra parts required.
Installation Procedure
1. Side mount clip into pin guide.
2. Press against work surface. Fire tool.
3. Install the cable or conduit/tube as required. Fasten tie strap.
Pin Selection Guide
Substrate HC617 HC622
Hard Concrete >50MPa 4 4
Concrete <50MPa 4 4
Hollow Concrete Block k 4
Steel 4 4
Steel Decking 4 4
4 Suitable k Possible
*NOTE: Test concluded when clip pulled over pin head or cable tie failed. Job-site testing may be required to determine actual achievable job-site values.
Results have been achieved with a CableMaster™
tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed and a new fixing
set away from any spalled concrete. Tension loads provided are for static load situations only. Values represent a minimum factor of safety of 3:1 on the lowest
test results achieved. Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, however a minimum of 3 fixings
per fastening unit should be used.
Features & Benefits
• CTClip can be used for cable, conduit and tube work.
• Maximum cable cluster or tube diameter of 32mm.
• Clip base raised above work surface.
• In-built energy absorber for optimum pin penetration.
• Side mount clip into pin guide.
• One handed installation.
• Fix from the ground with the PulsaLift™
Pole.
• No drilling required.
Application test on-site before use is recomended.
42. CONSTRUCTION SYSTEMS INDIA42
EClip™
Conduit and Pipe Clip
Performance Table
Tube extraction loads at 22°C
Force required to manually remove tube from the clip
Clip Size Average Ultimate Load (approx)
16mm 4kg
20mm 6kg
25mm 8kg
Pin Selection Guide
Substrate HC617 HC622
Hard Concrete >50MPa 4 4
Concrete <50MPa 4 4
Hollow Concrete Block k 4
Steel 4 4
Steel Decking 4 4
4 Suitable k Possible
Description
The EClip™ is ideal for firmly securing conduit, plastic and metal pipes.
Once installed, the clip is able to be rotated to allow for precise positioning
of rigid and flexible tube. The design of the EClip™ incorporates interlocking
connections to allow for multiple clips to be joined together side by side for a
professional finish.
Specifications
Raw Material
High quality polypropylene
Halogen free. Fire resistant
Spacing Recommendation 0.5 and 1 metre (approx)
EClip™
Pulsa 800
Part No
Description Pipe / Conduit
Diameter
Order Qty
P8CPGEC16 Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) 16mm 1
P8CPGEC20 Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) 20mm 1
P8CPGEC25 Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) 25mm 1
Installation Procedure
1. Side mount the EClip™ onto the tool Pin Guide.
2. Fixing is quick and precise.
3. When fixed, it can be easily rotated around the pin to adjust
its position.
Features & Benefits
• The EClip™
is designed to clip easily onto the CableMaster™
Pin Guide
from the side allowing one-handed operation.
• After installation the EClip™
can be rotated around the pin to adjust
alignment.
• The slotted design of EClip™
absorbs energy, preventing the pin head
from splitting the clip.
• The hollow structure of the EClip™
gives flexibility for easy insertion of
conduit.
• EClip™ incorporates male/female connections allowing multiple conduit
installation side by side.
• No drilling required.
Application test on-site before use is recomended.
43. CONSTRUCTION SYSTEMS INDIA43
Catenary Wire Bracket™
Application test on-site before use is recomended.
Catenary Wire Bracket Assembly
Pulsa 800
Part No
Description Order Qty
P8CPGCWB
Catenary Wire Bracket Contractor Pack (400 x brackets, HC617 Pins, Fuel Cell,
200mm x 4.8mm Black)
1
Specifications
Steel type CA2S-E.
Steel Thickness
2mm providing a high resistance to
deformation.
Nominal Fixing Hole Diameter 7.5mm
Description
Reinforced steel angle bracket, with closed eye for catenary wire and cable
installations when fixing to concrete, concrete block and steel. Suitable for
light to medium duty, close to ceiling applications.
At each end of the catenary
wire run (or as required)
a mechanical anchor eye
bolt should be used for
maximum strength and
tensioning of the wire
Pin Selection Guide
Substrate HC617 HC622
Hard Concrete >50MPa 4 4
Concrete <50MPa 4 4
Hollow Concrete Block 4 4
Steel 4 k
Steel Decking 4 4
4 Suitable k Possible
Installation Procedure
1. Place bracket assembly into the pin guide.
2. Depress pin guide against work surface, fix bracket
into position.
3. Attach cables and wires as required.
Features & Benefits
• For catenary wire, cable, and hanger rod installations when fixing to
concrete, hollow block and steel.
• Improved clampdown to work surface with dimpled baseplate.
• Optimum pin penetration with cushioned base.
• Strengthening ribs reduce bracket twist and deformation.
• Rounded edges to prevent cable damage.
• Suits light to medium duty fixing applications.
(see performance table)
• Eye size - 7mm.
Performance Table*
Load Capacity (Tension)
Product - Concrete 32MPa
Cat Brkt Pulsa assembly, HC617 Pin 14kg
*Notes:
1.Values represent the maximum recommended working load in tension. 2. A minimum of 5 fastenings per fastened unit
must be used. 3.Results have been achieved with a CableMaster™ tool. 4. All visible failures must be replaced and a new
fixing set away from any spalled concrete. 5.Tension loads provided are for static load situations only. 6. Job-site testing
may be required to determine actual achievable job-site values 7.Minimum edge distance 75mm. Minimum spacing
between fixings 50mm.
44. CONSTRUCTION SYSTEMS INDIA44
Strap and Plate Washer
Strap and Plate Washer
Part No Description Order Qty
SPMW Strap and Plate Washer 500
Installation Procedure
1. Gently place washer assembly into end of nose piece.
2. Place assembly tip in position.
3. Depress nose piece against work surface, fire tool.
Description
The Strap and Plate Washer may be used in a wide variety of applications
where thin materials or fixtures with existing holes need to be quickly
fastened. Common applications where the Strap and Plate washer are
used include securing thin metal, nylon and Velcro straps for ducting, cable
bunches and other fixtures. Brackets with existing pre-drilled holes for
traditional mechanical fasteners can be secured with the use of strap and
plate washers.
Pin Selection Guide
Substrate HC617 HC622
Hard Concrete >50MPa 4 4
Concrete <50MPa 4 4
Hollow Concrete Block 4 4
Steel 4 4
Steel Decking 4 4
4 Suitable k Possible
Features & Benefits
• FAST One-Step Fixing of metal, nylon and velcro straps for ductwork, cable
bunches and fixture installations.
• Suitable to span wide mounting holes in cable suspension brackets or
switchboxes up to 8mm diam.
• To reinforce mounting holes in brackets and prevent fixture pullover.
• Precise hole alignment.
• Use with pre-drilled or solid straps and plates.
• Suitable for use with CableMaster™ Pulsa™ collated pins.
• Choose the pin length to suit the application.
• One handed fixing to concrete, hollow block and steel.
45. engineers, right through to a National Customer Service Centre providing order placement and delivery coordination. Reid supports
MORETHANMEETSTHEEYE
Contact the Reid Customer Service Centre 1300 780 250 or visit www.reid.com.au
E N G I N E E R E D S O L U T I O N S F O R C O N C R E T EE N G I N E E R E D S O L U T I O N S F O R C O N C R E T E
ITW Construction Systems | www.itwcsanz.com
Contact local office or go to www.itwcs.co.in
46. CONSTRUCTION SYSTEMS INDIA46
Hammer Drill Driver 18V Three Mode Drill
Description
A powerful 18 volt combination tool for high torque drilling, screwdriving
and percussion drilling.
Specification
Battery Pack 18 V / 4.0 Ah
Battery Type Li-Ion
No Load Speed (1st gear / 2nd gear) 0 - 450 / 0 - 1800 rpm
Beats Per Minute (1st gear / 2nd gear) 0 - 7200 / 0 - 28000 bpm
Max. Drilling Capacity Steel / Wood /
Masonry
13 / 38 / 16 mm
Torque Settings 24
Max Torque 75 Nm
Weight incl. Battery 2.6 kg
Features & Benefits
• 4 pole frameless motor generating a impressive 75Nm of torque
• Variable speed trigger for enhanced control
• Percussion drill mode for masonry and stone drilling
• 24 stage torque adjustment
• Spindle lock plus keyless chuck - convenient bit change with one hand
• Large ergonomic soft grip design for comfortable use
• 2 year warranty
Hammer Drill Driver
Part No Description Order Qty
CHDDR18 Hammer Drill Driver*(bare tool only) 1
CBATR18 18V Battery 3ah 1
CBATR18HD 18V Battery 4ah 1
CCR18 18V Battery Charger 1
*Can be purchased as bare unit or as part of a kit.
Related Products
Battery (4.0Ah Lithium Ion - CBATR18HD)
Charger ( CCR18 )
Driver Bits
4 pole frameless
motor generates
high torque
Built in LED to
illuminate workspace
All metal single sleeve
13mm/ 1/2” tungsten
carbide jaw chuck
Trades & Applications
Builder Plumber Electrician Carpenter HVAC
Timber / Steel
Drilling
4 4 4 4 4
Masonry Drilling 4 4 4 4 4
Screw Driving 4 4 4 4 4
Noise / Vibration Information
Sound pressure level: 75.5dB (A)
Sound power level: 86.5dB (A)
Wear ear and eye protection.
Vibration: The typical weighted
acceleration does not exceed
11.6m/s2
.
Belt clip
Large overmold
soft grip handle for
increased comfort
Charger & Battery
18V Power Supply
CBATR18 CHDDR18 + CBATR18