SlideShare a Scribd company logo
1 of 23
NatureTech Solutions
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Providing Industries with Safe Non
Chemical Sanitizing & Cleaning
Solutions
-=-=-=-=-=-=-=-=-=-=-=-=-=-
NTS© -- 2440 Butter Rd. / Lancaster, PA 17601
Office: 717-394-2275 Fax: 717-394-2283
NTS© industry applications:
• Commercial Facilities
• Agriculture Industry
• Schools buildings and
gyms/sports fields
• Hospitals
• Bottling
• Factory & Truck
Sanitation
• All Cleaning needs
• Brewing
• Food Retailers
• Produce
• Food Preparation
• Office Sanitation
• Food Processing
• Water Sanitation
• Organic Products
• Inquire About Your
Industry or Need
NTS© systems:
• Providing Green solutions on-site to create
a sanitizer (Anolyte)* and a cleaner
(Catholyte)**.
• This technology is based on
electrochemical activation of water or
what we call NEWater© and has been
developed in line with the world trend to
reduce the amount of chlorine and other
chemicals currently used to purify,
disinfect, sterilize and use of cleaning
solutions.
*Acidic ** Alkaline
What is Neutral Electrolyzed Water?
NEWater©
• Neutral Electrolyzed Water (or NEWater© is
a non-toxic, non-irritant, environmentally
and ecologically safe sanitizing solution
produced from the electrochemical
reaction of water, salt and electricity.
• NEWater© is proven to be more effective
against bacteria, viruses, noroviruses,
molds and other microbiological organisms
than Chlorine* solutions alone and, yet,
remains benign enough to ingest in
concentrated form .
*Hypochlorous Acid
The human body produces a highly effective antimicrobial solution called
hypochlorous acid to fight infection. White blood cells release this natural
oxidant to fight invading pathogens. The hypochlorous acid produced by the
human body’s immune system:
1. Reacts readily with a variety of microbial sub-cellular compounds
2. Interferes with their metabolic processes
3. Kills individual bacterium exposed within milliseconds
A. When a wound breaks human skin, it
creates a gateway for harmful
pathogens to invade human cells.
B. Neutrophils, which are a type of white
blood cell, live in human blood vessels.
C. When pathogens invade a human cell,
neutrophils travel to the infection site
to destroy the invading pathogen. The
first step in this process is engulfing the
pathogen.
D. Once the neutrophil has completely
surrounded the pathogen, it produces
an oxidant, hypochlorous acid.
Hypochlorous acid is a biocide, meaning
it kills organic material. Once produced
by the neutrophil, it kills the bacteria
almost instantly.
Germ Surfaces carry a natural negative
electrical charge. For that reason,
Hypochlorice ion (OCL) is repelled in the
vicinity of germ surfaces and they form a
resistance to it, while by using Hypochlorous
acid (HOCL) at a pH of 2.5-3.5 or 5-6.8 it can
easily penetrate those surfaces.
Hypochlorous acid pierces the barriers of
germs and resistance layers, destroying
these microscopic agents of disease. U of MN
stated that HOCL is about 80 to 200 times
more antimicrobial then OCL
Why Does HOCL Works So Well
NEWater© Efficient because:
• NEWater© is generated on demand and applied where
required to eliminate the logistical concerns of
purchasing, transporting, storing, preparing and using
traditional chemical applications
• The elimination of hazardous chemicals translates into
reductions in regulatory paperwork, safety training
requirements, safety inspections, and liability
exposure
• Eliminates the need to monitor for chlorine dioxide
residuals, chlorite, or bromide
• Provides more effective cleaning ability than other
toxic chemicals.
• The higher biocide capacity relative to traditional
chemical solutions permits the use of lower dose
rates, lessening the risk for environmental impact
• The solution is less corrosive than alternate products.
• Reduces the frequency of cleaning within a facility
• Allows for the disinfection of areas where toxic
chemicals are not permitted
Acidic Solution or NEWater ©
Sanitizer (Anolyte)
• NEWater© offers many advantages over traditional
chemical technologies, including:
• Safety
• Superior disinfection performance
• Removal of biofilm
• A more stable, longer-lasting chlorine residual
• enhanced micro flocculation (reduction in turbidity)
• Improved taste and odor
• Oxidation of iron, manganese and hydrogen sulfide
To date no virus, bacteria and mold has been able to
develop any adaptive resistance to Anolyte. Further,
when NEWater© Sanitizer is applied at different
dosing levels, it may be used for virtually all sanitizing
needs.
Alkaline Solution or NEWater©
Cleaner (Catholyte)
Catholyte primary function is to dissolve and remove
grease, fats and other caked on debris besides
preventing or eliminating the following:
• The need for storage/use of chlorine and other
chemical cleaners in the work place that can create an
extremely toxic environment posing significant health
hazards and safety risks for employees…and…
• By using NTS© it may help management in decreased
health insurance premiums / claims and improving
“the bottom line”.
• Accidental spills or incorrect mixing can result in
chlorine gas (fatal), chemical burns and severe lung
damage in a matter of seconds. NEWater© products
virtually eliminate or radically reduce chemical use as
it is not harmful to humans.
NEWater© Properties:
NEWater© Sanitizer (Anolyte) acidic solution
• Consistently pH neutral 5.6 –6.8
• Stable chlorine based oxidizing solution
with Oxidation Reduction Potential of
+800mV
• Free available chlorine of 50-200 MG/L.
NEWater© Cleaner (Catholyte) alkaline
solution
• A reducing solution with antioxidant and
surfactant prosperities
• A pH of 12 to13
• A oxidation Reduction Potential 0f –
900mV.
The safety of NEWater© cleaning products:
• Neutral Electrolyzed Water, in its most
concentrated form, could be ingested
without any physical harm…though not
recommended.
• The only elements introduced into the
system (water, salt and electricity) are all
safe and environmentally friendly.
• NEWater© is effective against a multitude
of microbiological organisms.
NEWater©
Effective against micro organisms:
• NEWater© uses Free Available Chlorine* (50-
200 ppm) to break apart bacteria, viruses and
micro organisms on a molecular level.
*Free available Chlorine: Chlorine that is available to act upon foreign substances.
• NEWater© is also more effective than Chlorine
alone in the elimination of biofilms.
• Biological organisms can not build an adaptive
resistance to NEWater© as they can to
Chlorine*.
*Hypochlorous acid
NTS© systems efficacy:
When this system is applied, studies have shown substantial
reduction
or simple eradication of the following (non-inclusive) list of
examples:
• Bacillus anthraces (anthrax)
• Bacillus cereus
• Bacillus stearothermophilus
• Bacillus subtilis spore
• Bacteriophage (F2)
• Clostricium perfringens
spore
• Coliohage MS2
• Cryptosporidium pafvum
oocyst
• Escherichia Coli
• Francisella tularensis
• Giardia muris cyst
• Leprosy
• All Avian Flu’s
• Hepatitis A Virus (HAV)
• Hepatitis virus analog (F2)
• Klebsiella terrigena
• Legionella pneumopnila
• Listeria monocytogenes
• Psedumonas aeruginosa
• Salmonella typhimurium
• Staphylococcus aureus
• Vaccina virus (smallpox)
• Vibrio cholerae
• MRSA
• Mold
• Plaque
• Many more
NEWater© applications:
• Fogging: Effective against
airborne bacteria, viruses
and other micro organisms.
• Humidifying: Introduce
the solution into a forced air
humidifying system to
sanitize the air in a confined
space such as an office
building, cruise ship or
airplane.
• Dosing: Reduced amounts
of solution can be
introduced into the water
system to sanitize incoming
water in a facility for use as
drinking water or for food
safety.
• Mold Remediation: Even
though this is a water based
solution, mold is killed on
contact
• Concentrated: The
solution can be used as a
cleaner or sanitizer without
the risk of harm to higher
organisms.
• Frozen: Can be dosed into
ice machines--creating
sanitized ice.
• Spraying: Most widely
used for all surface
sanitizing from
vegetables/produce to all
hard surfaces, bathrooms,
kitchens, equipment etc.
Approved use of NTS© systems.
• EPA Pesticide Generation Mfg. Establishment number 85215-PA-001 allowing use
of NEWater© on-site use in the food industry.
• USDA has stated they have no objections for the use of NEWater© in the Meat,
Poultry, or Egg production industries.
• USDA included electrolyzed water on its list of pesticides published as 7120.1 Amend
11 dated 4/11/2007.
FDA has also expressed no concerns and holds no opposition for the use of
electrolyzed water.
• NEWater©) is approved under 21 CFR 173.315 for direct contact with processing
foods
• NEWater©) is approved for several indirect food contact applications under 21 CFR
176.170 and 21 CFR 177.2800. IT is an approved sanitizer that meets 21 CFR
178.1010
• EPA has given approval (40 CFR 180.1054) for washing raw foods that are
consumed without processing.
• EPA under 40 CFR 180.940 allows NTS Anolyte to be generated on site as part of
Antimicrobial formulation for sanitizers used on all surfaces including food contact
surfaces
• On-Site Generation exemption. Only ingredients are NACI and H2O (not regulated)
PR 2000 Exemption
• Neutral Electrolyzed Water (NEWater©)in its concentrated form cannot be
classified as hazardous in accordance with Directive 99/45/EC. Normal
COSHH* regulations apply. Rated as 0
*COSHH: Control of Substances Hazardous to Health Regulations.
Why should you use NTS©
systems?
• Organic, safe, non-toxic Non Chemical solution.
• Lowers the risk of health concerns within the work place.
Lowers Absenteeism.
• The solution is available on-site/on-demand…24/7.
• More effective than other sanitization chemicals.
• Machines are depreciable assets.
• Reduction in the frequency of cleaning within a facility.
• Reduced risk of consumer health concerns.
• Marketability of new and improved sanitation methods.
• More effective cleaning ability than alternate toxic
chemicals.
Added Benefits of NTS©
systems:
• Eliminates or reduces the
need for costly and potentially
toxic chemicals.
• Completely safe, non-harmful,
green product using only
natural ingredients.
• More effective sanitization
then Chlorine* alone.
• Natural pesticide that can be
used on-demand and
produced on-site.
• The systems are all “plug and
play” and require little
adjustment. Easy to operate.
• Extends shelf life of products.
• Could be used effectively to
protect against bio-terrorism.
*Hypochlorous acid
• All systems are reliable and
100% duty cycle.
• The solution is less corrosive
then alternate products.
• A single unit produces a
natural solution to supply a
facility with numerous cost
effective applications.
• Risk mitigation.
• Lowers contamination and
cross contamination.
• Systems are mobile.
• Maintenance agreements are
available.
NTS Cat 1
NTS 4000
NTS 4000P
NTS 4000S
NTS MS 2000NTS ECO-1
NTS ECO-1
New Revolutionary Design.
Hand held mini Hypochlorous
Acid (non chemical sanitizer)
to fulfill you small immediate
needs for sanitizing…kitchens
to bathrooms. In fact, any and
all hard surfaces. Also, suitable
for spraying fruits and
vegetables against all bacteria.
Safe to use around humans
and animals. Hypochlorus Acid
is approved to be used as a
sanitizer/disinfectant by the
EPA, FDA, and USDA
NTS MS 2000
This is the perfect
small sanitizing
machine when large
volume is not
necessary. Suitable
for labs, restaurants,
small farms, and
doctor and dentist
offices. Produces 32
gallons per hour
NTS
4000
NTS
4000 NTS
4000S
Sanitizing machines
for small to large
volume needs.
Models range from
table top units @ 32
to 48 gallons and
hour, to a larger
floor standing
machine @ 64
gallons per hour
NTS Cat 1
Catholyte generator producing soap
– known as Sodium hydroxide
Generate all the soap
needed for large scale
projects. Perfect for
cleaning factories, use in
floor scrubbers, grocery
stores, food processing,
hotels, and truck cleaning.
Produces 32 gallons of
sodium hydroxide per hour.
NatureTech Solutions
For further information please contact:
Roman Fyk,
President
2440 Butter Rd.
Lancaster, PA 17601
Cell: 717-419-1909 E-mail: roman@naturetechsolutions.com
Office: 717-394-2275 Fax: 717-394-2283

More Related Content

What's hot

Disinfectants- Pharmaceutical Microbiology
Disinfectants- Pharmaceutical MicrobiologyDisinfectants- Pharmaceutical Microbiology
Disinfectants- Pharmaceutical MicrobiologySanchit Dhankhar
 
Microbial contamination
Microbial contamination Microbial contamination
Microbial contamination Rinaldo John
 
Bio medical waste management
Bio medical waste management Bio medical waste management
Bio medical waste management Rahul Ratnakumar
 
Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International
 Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International
Sodium Laureth Sulfate Manufacturers - Prakash Chemicals Internationalanshparmar
 
Bioburden Testing
Bioburden TestingBioburden Testing
Bioburden TestingDocKetchum
 
Sterillization moistheat and dery heat
Sterillization moistheat and dery heat Sterillization moistheat and dery heat
Sterillization moistheat and dery heat BasantsinghSingh
 
Oil Technics Ltd: Road bio
Oil Technics Ltd: Road bioOil Technics Ltd: Road bio
Oil Technics Ltd: Road bioDavid Holmes
 
Chemical agents of sterilization
Chemical agents of sterilizationChemical agents of sterilization
Chemical agents of sterilizationJessabeth Aluba
 
Disinfection and Its types
Disinfection and Its typesDisinfection and Its types
Disinfection and Its typesDr. Chhavi Bajaj
 
4. Design, Trust & Control of Sterile Manufacturing (Observations)
4. Design, Trust & Control of Sterile Manufacturing (Observations)4. Design, Trust & Control of Sterile Manufacturing (Observations)
4. Design, Trust & Control of Sterile Manufacturing (Observations)Obaid Ali / Roohi B. Obaid
 
Egx 101 epa fact sheet 15032011
Egx 101 epa fact sheet 15032011Egx 101 epa fact sheet 15032011
Egx 101 epa fact sheet 15032011entogenex
 
Impurities in Pharmaceuticals: Sources of impurities
Impurities in Pharmaceuticals: Sources of impuritiesImpurities in Pharmaceuticals: Sources of impurities
Impurities in Pharmaceuticals: Sources of impuritiesGopi Patel
 
Viriditec PowerPoint gregB
Viriditec PowerPoint gregBViriditec PowerPoint gregB
Viriditec PowerPoint gregBstuart burow
 

What's hot (18)

Disinfectants- Pharmaceutical Microbiology
Disinfectants- Pharmaceutical MicrobiologyDisinfectants- Pharmaceutical Microbiology
Disinfectants- Pharmaceutical Microbiology
 
Microbial contamination
Microbial contamination Microbial contamination
Microbial contamination
 
Bio medical waste management
Bio medical waste management Bio medical waste management
Bio medical waste management
 
Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International
 Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International
Sodium Laureth Sulfate Manufacturers - Prakash Chemicals International
 
Bioburden Testing
Bioburden TestingBioburden Testing
Bioburden Testing
 
Sterillization moistheat and dery heat
Sterillization moistheat and dery heat Sterillization moistheat and dery heat
Sterillization moistheat and dery heat
 
Aseptic processing
Aseptic processingAseptic processing
Aseptic processing
 
Br biosanitizer i_e3
Br biosanitizer i_e3Br biosanitizer i_e3
Br biosanitizer i_e3
 
Oil Technics Ltd: Road bio
Oil Technics Ltd: Road bioOil Technics Ltd: Road bio
Oil Technics Ltd: Road bio
 
Glutaraldehyde
GlutaraldehydeGlutaraldehyde
Glutaraldehyde
 
Glutaraldehyde
GlutaraldehydeGlutaraldehyde
Glutaraldehyde
 
Chemical Disinfectants
Chemical DisinfectantsChemical Disinfectants
Chemical Disinfectants
 
Chemical agents of sterilization
Chemical agents of sterilizationChemical agents of sterilization
Chemical agents of sterilization
 
Disinfection and Its types
Disinfection and Its typesDisinfection and Its types
Disinfection and Its types
 
4. Design, Trust & Control of Sterile Manufacturing (Observations)
4. Design, Trust & Control of Sterile Manufacturing (Observations)4. Design, Trust & Control of Sterile Manufacturing (Observations)
4. Design, Trust & Control of Sterile Manufacturing (Observations)
 
Egx 101 epa fact sheet 15032011
Egx 101 epa fact sheet 15032011Egx 101 epa fact sheet 15032011
Egx 101 epa fact sheet 15032011
 
Impurities in Pharmaceuticals: Sources of impurities
Impurities in Pharmaceuticals: Sources of impuritiesImpurities in Pharmaceuticals: Sources of impurities
Impurities in Pharmaceuticals: Sources of impurities
 
Viriditec PowerPoint gregB
Viriditec PowerPoint gregBViriditec PowerPoint gregB
Viriditec PowerPoint gregB
 

Similar to NEWater

Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...Indoor Air Sterilization Soma Medical IAQA
 
BiODX - Antimicrobial Technology Presentation
BiODX - Antimicrobial Technology PresentationBiODX - Antimicrobial Technology Presentation
BiODX - Antimicrobial Technology PresentationGraham_Poultney
 
Wilkins Solutions Surface Recontaminaion Shielding 2014
Wilkins Solutions Surface Recontaminaion Shielding 2014Wilkins Solutions Surface Recontaminaion Shielding 2014
Wilkins Solutions Surface Recontaminaion Shielding 2014Nashville Fitness Supply
 
Disinfectant Brochure_Chemtex_Jun20
Disinfectant Brochure_Chemtex_Jun20Disinfectant Brochure_Chemtex_Jun20
Disinfectant Brochure_Chemtex_Jun20Debabrata Bose
 
Vital oxide power point
Vital oxide power pointVital oxide power point
Vital oxide power pointXL North
 
IWM Pharmaceutical.pptx
IWM Pharmaceutical.pptxIWM Pharmaceutical.pptx
IWM Pharmaceutical.pptxAyushPanwar30
 
Biomedical Waste Management with Case Study ppt by Avaneesh Yadav
Biomedical Waste Management with Case Study ppt by Avaneesh YadavBiomedical Waste Management with Case Study ppt by Avaneesh Yadav
Biomedical Waste Management with Case Study ppt by Avaneesh YadavMNNIT Allahabad
 
22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI
22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI
22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMIRedit
 
Microbial issues in cleaning validation.pptx
Microbial issues in cleaning validation.pptxMicrobial issues in cleaning validation.pptx
Microbial issues in cleaning validation.pptxRushali6
 
Sterilization and thermal death kinetics
Sterilization and thermal death kineticsSterilization and thermal death kinetics
Sterilization and thermal death kineticsyogyatathakur85059
 
Exploring Peracetic Acid as Disinfectant and Sanitizer in Several Industries
Exploring Peracetic Acid as Disinfectant and Sanitizer in Several IndustriesExploring Peracetic Acid as Disinfectant and Sanitizer in Several Industries
Exploring Peracetic Acid as Disinfectant and Sanitizer in Several Industriesssuser8003ee
 
SAFETY BELT AND FIRE HELMET By Shubh Enterprises
SAFETY BELT AND FIRE HELMET By Shubh EnterprisesSAFETY BELT AND FIRE HELMET By Shubh Enterprises
SAFETY BELT AND FIRE HELMET By Shubh EnterprisesIndiaMART InterMESH Limited
 

Similar to NEWater (20)

Vital Oxide (Web)
Vital Oxide (Web)Vital Oxide (Web)
Vital Oxide (Web)
 
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
 
BiODX - Antimicrobial Technology Presentation
BiODX - Antimicrobial Technology PresentationBiODX - Antimicrobial Technology Presentation
BiODX - Antimicrobial Technology Presentation
 
Wilkins Solutions Surface Recontaminaion Shielding 2014
Wilkins Solutions Surface Recontaminaion Shielding 2014Wilkins Solutions Surface Recontaminaion Shielding 2014
Wilkins Solutions Surface Recontaminaion Shielding 2014
 
Disinfectant Brochure_Chemtex_Jun20
Disinfectant Brochure_Chemtex_Jun20Disinfectant Brochure_Chemtex_Jun20
Disinfectant Brochure_Chemtex_Jun20
 
Vital oxide power point
Vital oxide power pointVital oxide power point
Vital oxide power point
 
IWM Pharmaceutical.pptx
IWM Pharmaceutical.pptxIWM Pharmaceutical.pptx
IWM Pharmaceutical.pptx
 
applications
applicationsapplications
applications
 
Silver Hydrogen Peroxide
Silver Hydrogen PeroxideSilver Hydrogen Peroxide
Silver Hydrogen Peroxide
 
Biomedical Waste Management with Case Study ppt by Avaneesh Yadav
Biomedical Waste Management with Case Study ppt by Avaneesh YadavBiomedical Waste Management with Case Study ppt by Avaneesh Yadav
Biomedical Waste Management with Case Study ppt by Avaneesh Yadav
 
22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI
22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI
22_DE LA I+D+i AL MERCADO_SERVYECO_BIOMOMI
 
Microbial issues in cleaning validation.pptx
Microbial issues in cleaning validation.pptxMicrobial issues in cleaning validation.pptx
Microbial issues in cleaning validation.pptx
 
Sterilization and thermal death kinetics
Sterilization and thermal death kineticsSterilization and thermal death kinetics
Sterilization and thermal death kinetics
 
Bio medical waste management
Bio medical waste managementBio medical waste management
Bio medical waste management
 
Exploring Peracetic Acid as Disinfectant and Sanitizer in Several Industries
Exploring Peracetic Acid as Disinfectant and Sanitizer in Several IndustriesExploring Peracetic Acid as Disinfectant and Sanitizer in Several Industries
Exploring Peracetic Acid as Disinfectant and Sanitizer in Several Industries
 
Peracetic acid
Peracetic acidPeracetic acid
Peracetic acid
 
Vital Oxide®
Vital Oxide®Vital Oxide®
Vital Oxide®
 
Catalog tui ep tiet trung anios - 3 m - wipak
Catalog tui ep tiet trung   anios - 3 m - wipakCatalog tui ep tiet trung   anios - 3 m - wipak
Catalog tui ep tiet trung anios - 3 m - wipak
 
Cleaning & Disinfecting
Cleaning & DisinfectingCleaning & Disinfecting
Cleaning & Disinfecting
 
SAFETY BELT AND FIRE HELMET By Shubh Enterprises
SAFETY BELT AND FIRE HELMET By Shubh EnterprisesSAFETY BELT AND FIRE HELMET By Shubh Enterprises
SAFETY BELT AND FIRE HELMET By Shubh Enterprises
 

NEWater

  • 1. NatureTech Solutions -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=- Providing Industries with Safe Non Chemical Sanitizing & Cleaning Solutions -=-=-=-=-=-=-=-=-=-=-=-=-=- NTS© -- 2440 Butter Rd. / Lancaster, PA 17601 Office: 717-394-2275 Fax: 717-394-2283
  • 2. NTS© industry applications: • Commercial Facilities • Agriculture Industry • Schools buildings and gyms/sports fields • Hospitals • Bottling • Factory & Truck Sanitation • All Cleaning needs • Brewing • Food Retailers • Produce • Food Preparation • Office Sanitation • Food Processing • Water Sanitation • Organic Products • Inquire About Your Industry or Need
  • 3. NTS© systems: • Providing Green solutions on-site to create a sanitizer (Anolyte)* and a cleaner (Catholyte)**. • This technology is based on electrochemical activation of water or what we call NEWater© and has been developed in line with the world trend to reduce the amount of chlorine and other chemicals currently used to purify, disinfect, sterilize and use of cleaning solutions. *Acidic ** Alkaline
  • 4. What is Neutral Electrolyzed Water? NEWater© • Neutral Electrolyzed Water (or NEWater© is a non-toxic, non-irritant, environmentally and ecologically safe sanitizing solution produced from the electrochemical reaction of water, salt and electricity. • NEWater© is proven to be more effective against bacteria, viruses, noroviruses, molds and other microbiological organisms than Chlorine* solutions alone and, yet, remains benign enough to ingest in concentrated form . *Hypochlorous Acid
  • 5. The human body produces a highly effective antimicrobial solution called hypochlorous acid to fight infection. White blood cells release this natural oxidant to fight invading pathogens. The hypochlorous acid produced by the human body’s immune system: 1. Reacts readily with a variety of microbial sub-cellular compounds 2. Interferes with their metabolic processes 3. Kills individual bacterium exposed within milliseconds A. When a wound breaks human skin, it creates a gateway for harmful pathogens to invade human cells. B. Neutrophils, which are a type of white blood cell, live in human blood vessels. C. When pathogens invade a human cell, neutrophils travel to the infection site to destroy the invading pathogen. The first step in this process is engulfing the pathogen. D. Once the neutrophil has completely surrounded the pathogen, it produces an oxidant, hypochlorous acid. Hypochlorous acid is a biocide, meaning it kills organic material. Once produced by the neutrophil, it kills the bacteria almost instantly.
  • 6. Germ Surfaces carry a natural negative electrical charge. For that reason, Hypochlorice ion (OCL) is repelled in the vicinity of germ surfaces and they form a resistance to it, while by using Hypochlorous acid (HOCL) at a pH of 2.5-3.5 or 5-6.8 it can easily penetrate those surfaces. Hypochlorous acid pierces the barriers of germs and resistance layers, destroying these microscopic agents of disease. U of MN stated that HOCL is about 80 to 200 times more antimicrobial then OCL Why Does HOCL Works So Well
  • 7. NEWater© Efficient because: • NEWater© is generated on demand and applied where required to eliminate the logistical concerns of purchasing, transporting, storing, preparing and using traditional chemical applications • The elimination of hazardous chemicals translates into reductions in regulatory paperwork, safety training requirements, safety inspections, and liability exposure • Eliminates the need to monitor for chlorine dioxide residuals, chlorite, or bromide • Provides more effective cleaning ability than other toxic chemicals. • The higher biocide capacity relative to traditional chemical solutions permits the use of lower dose rates, lessening the risk for environmental impact • The solution is less corrosive than alternate products. • Reduces the frequency of cleaning within a facility • Allows for the disinfection of areas where toxic chemicals are not permitted
  • 8. Acidic Solution or NEWater © Sanitizer (Anolyte) • NEWater© offers many advantages over traditional chemical technologies, including: • Safety • Superior disinfection performance • Removal of biofilm • A more stable, longer-lasting chlorine residual • enhanced micro flocculation (reduction in turbidity) • Improved taste and odor • Oxidation of iron, manganese and hydrogen sulfide To date no virus, bacteria and mold has been able to develop any adaptive resistance to Anolyte. Further, when NEWater© Sanitizer is applied at different dosing levels, it may be used for virtually all sanitizing needs.
  • 9. Alkaline Solution or NEWater© Cleaner (Catholyte) Catholyte primary function is to dissolve and remove grease, fats and other caked on debris besides preventing or eliminating the following: • The need for storage/use of chlorine and other chemical cleaners in the work place that can create an extremely toxic environment posing significant health hazards and safety risks for employees…and… • By using NTS© it may help management in decreased health insurance premiums / claims and improving “the bottom line”. • Accidental spills or incorrect mixing can result in chlorine gas (fatal), chemical burns and severe lung damage in a matter of seconds. NEWater© products virtually eliminate or radically reduce chemical use as it is not harmful to humans.
  • 10. NEWater© Properties: NEWater© Sanitizer (Anolyte) acidic solution • Consistently pH neutral 5.6 –6.8 • Stable chlorine based oxidizing solution with Oxidation Reduction Potential of +800mV • Free available chlorine of 50-200 MG/L. NEWater© Cleaner (Catholyte) alkaline solution • A reducing solution with antioxidant and surfactant prosperities • A pH of 12 to13 • A oxidation Reduction Potential 0f – 900mV.
  • 11. The safety of NEWater© cleaning products: • Neutral Electrolyzed Water, in its most concentrated form, could be ingested without any physical harm…though not recommended. • The only elements introduced into the system (water, salt and electricity) are all safe and environmentally friendly. • NEWater© is effective against a multitude of microbiological organisms.
  • 12. NEWater© Effective against micro organisms: • NEWater© uses Free Available Chlorine* (50- 200 ppm) to break apart bacteria, viruses and micro organisms on a molecular level. *Free available Chlorine: Chlorine that is available to act upon foreign substances. • NEWater© is also more effective than Chlorine alone in the elimination of biofilms. • Biological organisms can not build an adaptive resistance to NEWater© as they can to Chlorine*. *Hypochlorous acid
  • 13. NTS© systems efficacy: When this system is applied, studies have shown substantial reduction or simple eradication of the following (non-inclusive) list of examples: • Bacillus anthraces (anthrax) • Bacillus cereus • Bacillus stearothermophilus • Bacillus subtilis spore • Bacteriophage (F2) • Clostricium perfringens spore • Coliohage MS2 • Cryptosporidium pafvum oocyst • Escherichia Coli • Francisella tularensis • Giardia muris cyst • Leprosy • All Avian Flu’s • Hepatitis A Virus (HAV) • Hepatitis virus analog (F2) • Klebsiella terrigena • Legionella pneumopnila • Listeria monocytogenes • Psedumonas aeruginosa • Salmonella typhimurium • Staphylococcus aureus • Vaccina virus (smallpox) • Vibrio cholerae • MRSA • Mold • Plaque • Many more
  • 14. NEWater© applications: • Fogging: Effective against airborne bacteria, viruses and other micro organisms. • Humidifying: Introduce the solution into a forced air humidifying system to sanitize the air in a confined space such as an office building, cruise ship or airplane. • Dosing: Reduced amounts of solution can be introduced into the water system to sanitize incoming water in a facility for use as drinking water or for food safety. • Mold Remediation: Even though this is a water based solution, mold is killed on contact • Concentrated: The solution can be used as a cleaner or sanitizer without the risk of harm to higher organisms. • Frozen: Can be dosed into ice machines--creating sanitized ice. • Spraying: Most widely used for all surface sanitizing from vegetables/produce to all hard surfaces, bathrooms, kitchens, equipment etc.
  • 15. Approved use of NTS© systems. • EPA Pesticide Generation Mfg. Establishment number 85215-PA-001 allowing use of NEWater© on-site use in the food industry. • USDA has stated they have no objections for the use of NEWater© in the Meat, Poultry, or Egg production industries. • USDA included electrolyzed water on its list of pesticides published as 7120.1 Amend 11 dated 4/11/2007. FDA has also expressed no concerns and holds no opposition for the use of electrolyzed water. • NEWater©) is approved under 21 CFR 173.315 for direct contact with processing foods • NEWater©) is approved for several indirect food contact applications under 21 CFR 176.170 and 21 CFR 177.2800. IT is an approved sanitizer that meets 21 CFR 178.1010 • EPA has given approval (40 CFR 180.1054) for washing raw foods that are consumed without processing. • EPA under 40 CFR 180.940 allows NTS Anolyte to be generated on site as part of Antimicrobial formulation for sanitizers used on all surfaces including food contact surfaces • On-Site Generation exemption. Only ingredients are NACI and H2O (not regulated) PR 2000 Exemption • Neutral Electrolyzed Water (NEWater©)in its concentrated form cannot be classified as hazardous in accordance with Directive 99/45/EC. Normal COSHH* regulations apply. Rated as 0 *COSHH: Control of Substances Hazardous to Health Regulations.
  • 16. Why should you use NTS© systems? • Organic, safe, non-toxic Non Chemical solution. • Lowers the risk of health concerns within the work place. Lowers Absenteeism. • The solution is available on-site/on-demand…24/7. • More effective than other sanitization chemicals. • Machines are depreciable assets. • Reduction in the frequency of cleaning within a facility. • Reduced risk of consumer health concerns. • Marketability of new and improved sanitation methods. • More effective cleaning ability than alternate toxic chemicals.
  • 17. Added Benefits of NTS© systems: • Eliminates or reduces the need for costly and potentially toxic chemicals. • Completely safe, non-harmful, green product using only natural ingredients. • More effective sanitization then Chlorine* alone. • Natural pesticide that can be used on-demand and produced on-site. • The systems are all “plug and play” and require little adjustment. Easy to operate. • Extends shelf life of products. • Could be used effectively to protect against bio-terrorism. *Hypochlorous acid • All systems are reliable and 100% duty cycle. • The solution is less corrosive then alternate products. • A single unit produces a natural solution to supply a facility with numerous cost effective applications. • Risk mitigation. • Lowers contamination and cross contamination. • Systems are mobile. • Maintenance agreements are available.
  • 18. NTS Cat 1 NTS 4000 NTS 4000P NTS 4000S NTS MS 2000NTS ECO-1
  • 19. NTS ECO-1 New Revolutionary Design. Hand held mini Hypochlorous Acid (non chemical sanitizer) to fulfill you small immediate needs for sanitizing…kitchens to bathrooms. In fact, any and all hard surfaces. Also, suitable for spraying fruits and vegetables against all bacteria. Safe to use around humans and animals. Hypochlorus Acid is approved to be used as a sanitizer/disinfectant by the EPA, FDA, and USDA
  • 20. NTS MS 2000 This is the perfect small sanitizing machine when large volume is not necessary. Suitable for labs, restaurants, small farms, and doctor and dentist offices. Produces 32 gallons per hour
  • 21. NTS 4000 NTS 4000 NTS 4000S Sanitizing machines for small to large volume needs. Models range from table top units @ 32 to 48 gallons and hour, to a larger floor standing machine @ 64 gallons per hour
  • 22. NTS Cat 1 Catholyte generator producing soap – known as Sodium hydroxide Generate all the soap needed for large scale projects. Perfect for cleaning factories, use in floor scrubbers, grocery stores, food processing, hotels, and truck cleaning. Produces 32 gallons of sodium hydroxide per hour.
  • 23. NatureTech Solutions For further information please contact: Roman Fyk, President 2440 Butter Rd. Lancaster, PA 17601 Cell: 717-419-1909 E-mail: roman@naturetechsolutions.com Office: 717-394-2275 Fax: 717-394-2283