(ATS6-APP07) Configuration ofAccelrys ELN to Clone to the LatestTemplate Version Todd ClementSenior Product ManagerAccelry...
Content• How to take advantage of the new capability to cloneexperiments to the latest template version• Template maintena...
Parent Template is treated as aStandard Operating Procedureand kept fully intact• Value: Enable users to take advantage of...
• Pre-6.8 clone behavior is configured by default• If Clone to the Latest Version of the Template is desired:– The Noteboo...
• To access the 6.8 fixes and features in a clonedexperiment it is necessary to update the ExperimentTemplate:– Check out ...
Alternatively, Map older Template Versions From the open 6.8 template,select ‘Map Templates forCloning…’ List of availab...
DemoAELN 6.8: Configuration of Clone to Latest
• The new document contains– Sections that are in both the Source Experiment and the Parent Template matched byName and se...
• AELN 6.8 includes new capabilities that enable re-use ofexisting documents with newly released functionality• Needs to b...
Questions?
Appendix
Primary Clone Support for SectionsText File Forms SpreadSheet References Table Materials RSS6.8 Tested Tested Tested Teste...
Additional Section SupportPreparations Formulations Recipe Morphit Plate ReactionList6.8 Tested Tested Tested Not supporte...
Upcoming SlideShare
Loading in …5
×

(ATS6-APP07) Configuration of Accelrys ELN to Clone to the Latest Template Version

507 views

Published on

Published in: Technology, Business
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
507
On SlideShare
0
From Embeds
0
Number of Embeds
6
Actions
Shares
0
Downloads
0
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

(ATS6-APP07) Configuration of Accelrys ELN to Clone to the Latest Template Version

  1. 1. (ATS6-APP07) Configuration ofAccelrys ELN to Clone to the LatestTemplate Version Todd ClementSenior Product ManagerAccelrys ELN Product Managementtodd.clement@accelrys.com
  2. 2. Content• How to take advantage of the new capability to cloneexperiments to the latest template version• Template maintenance and configuration• Demonstration and walk through of the AELN 6.8 clonefunctionality
  3. 3. Parent Template is treated as aStandard Operating Procedureand kept fully intact• Value: Enable users to take advantage ofnew features when cloning– Pre-6.8: Cloned documents are exact copiesof the source experiments– 6.8: Cloned documents are based on thenewest version of the Document Template• Each section in the new document pulls datafrom the corresponding section (matched bytitle and type) in the Source Experiment• How to configure Clone-to-Latest:– It is necessary to upgrade the ParentTemplate to Version 6.8 Sections– Alternatively, older templates can be mappedto new 6.8 templatesGeneral 6.8 Clone BehaviorParentTemplate1NewExperimentSourceExperiment2ExtractLoad
  4. 4. • Pre-6.8 clone behavior is configured by default• If Clone to the Latest Version of the Template is desired:– The Notebook application config file has a setting that willenable the new cloning behavior and disable pre-6.8 cloning<appSettings><add key="EnableCloneToLatest" value=“true" /></appSettings>• Can be distributed via a new Notebook profileClone Behavior Controlled via Application Config
  5. 5. • To access the 6.8 fixes and features in a clonedexperiment it is necessary to update the ExperimentTemplate:– Check out the experiment template– Update all document sections with 6.8 sections– Configure the new sections: scripts, mapping, toolbars,conditional formatting, etc.– Update the set of insertable sections to the 6.8 versions– Delete sections if appropriateTemplate Upgrade Maintenance
  6. 6. Alternatively, Map older Template Versions From the open 6.8 template,select ‘Map Templates forCloning…’ List of available templates isdisplayed Templates that are alreadymapped to anothertemplate are highlightedand unavailable for mappingto the open template
  7. 7. DemoAELN 6.8: Configuration of Clone to Latest
  8. 8. • The new document contains– Sections that are in both the Source Experiment and the Parent Template matched byName and section type– Unmatched sections that are in either the Source Experiment or the Parent Template– Inserted sections from the Source Experiment– Set of insertable sections from the Parent Template• If the source experiment has inserted sections or a section that’s not in theparent template then Notebook will clone the section using the pre-6.8 cloningbehavior– Creates a copy of the section as the original version• Parallel Chemistry– Library data (Discrete Reactants, Enumerated Products, Plate Layout, and Reaction Listsections) is not cloned– Generic Reaction Transform Options are not includedFinal Points of Interest
  9. 9. • AELN 6.8 includes new capabilities that enable re-use ofexisting documents with newly released functionality• Needs to be enabled, including template upgrademaintenance• Resources– Accelrys Electronic Lab Notebook Version 6.8 DeploymentGuide• (ATS6-APP09) ELN configuration management with ADMSummary
  10. 10. Questions?
  11. 11. Appendix
  12. 12. Primary Clone Support for SectionsText File Forms SpreadSheet References Table Materials RSS6.8 Tested Tested Tested Tested Tested Tested Tested Tested6.7.2000 Redirected Up Redirected Up Tested Redirected Up Redirected Up Tested Tested Tested6.7 Redirected Up Redirected Up Tested Redirected Up Redirected Up Tested Tested Tested6.6.200 Redirected Up Redirected Up Tested Redirected Up Redirected Up Tested Tested Tested6.6.0 Redirected Up Redirected Up Tested Tested Redirected Up Tested Tested Tested6.5 Redirected Up Redirected Up Tested Tested Redirected Up Tested Tested Tested6.4 Redirected Up Redirected Up Tested Tested Tested Tested Tested Tested6.3 Redirected Up Redirected Up Tested N/A N/A Tested Not supported Not supported6.2 Not supported Not supported Tested N/A N/A Not supported Not supported Not supported6.1 Not supported Not supported Tested N/A N/A Not supported Not supported N/A
  13. 13. Additional Section SupportPreparations Formulations Recipe Morphit Plate ReactionList6.8 Tested Tested Tested Not supported Tested Tested6.7.2000 Tested Tested Low Risk Not supported Tested Tested6.7 Tested Tested Low Risk Not supported Tested Tested6.6.200 Tested Tested Low Risk Not supported Tested Tested6.6.0 Tested Tested Low Risk Not supported Tested Tested6.5 Tested N/A Low Risk N/A Tested Tested6.4 Tested N/A Low Risk N/A Tested Tested6.3 N/A N/A N/A N/A Not supported Not supported6.2 N/A N/A N/A N/A N/A N/A6.1 N/A N/A N/A N/A N/A N/A

×